THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
08-Feb-21 |
Initial Release |
Affected OS Type | Affected Software Product | Affected Release | Affected Release Number | Comments |
---|---|---|---|---|
NON-IOS |
Application Patches |
21.sp1 |
21.sp1.2019.03 |
Defect ID | Headline |
---|---|
CSCvf34445 | There were no defects filed with this field notice at the time of publication. |
After application of AP.ums.21.sp1.551.ap366960, the CPU of the Unified Messaging Server (UMS) will increase and might result in service degradation.
Note: This field notice was originally posted in the BroadSoft Xchange portal and has been moved over to Cisco.com as-is for historical purposes.
High CPU conditions and possible service degradation.
BroadWorks patches can now be downloaded through the Cisco Software Download Center after logging in with your Cisco.com (CCO) account.
The version of BroadWorks that is currently deployed as well as the patches currently activated can be checked by executing the get versions all
command from the CLI. More information on how to check the patch level can be found in the Cisco BroadWorks Maintenance Guide.
Workaround
None
Patch
Apply patch AP.ums.21.sp1.551.ap368903 along with AP.ums.21.sp1.551.ap366960 to impacted servers. Those patches are now available on Xchange.
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
My Notifications—Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.