Monitoring the Supervisor in the Cisco cBR Chassis
Monitoring the Supervisor 250G in the Cisco cBR Chassis Using LEDs
LED |
Status |
Description |
---|---|---|
PWR STAT |
Off |
Supervisor Card is not powered up. |
Green |
Supervisor Card is powered up. |
|
Yellow |
Supervisor Card has a power fault - at least one voltage rail exceeded its voltage threshold limit. |
|
Blinking green at a 2 seconds rate |
Supervisor Card has a power fault - less than the minimum number of fan modules with no fault condition detected at power-on. |
|
Blinking yellow at a 2 seconds rate |
Supervisor Card has a power fault - less than the minimum number of power modules with no fault condition detected at power-on. |
|
Blinking between green and yellow at a 2 seconds rate |
Supervisor Card has a power fault - the Supervisor PIC is not detected at power-on. |
|
Blinking yellow at a 1/4 second rate |
Supervisor Card has a power fault - either the Supervisor PIC, SUP-DC, or SUP-MB did not respond with a PGOOD signal within 3 seconds after power-on. |
|
Blinking green at a 1/4 second rate |
Software on the other Supervisor Card has turned off power on this Supervisor Card. |
|
Blinking between green and yellow at a 1/4 seconds rate |
Secure Boot authentication has failed and Supervisor Card is powered down. |
|
RP STAT |
Off |
RP has not booted. |
Blinking green |
Software is loading. |
|
Green |
RP is operational. |
|
Yellow |
RP has detected a fault. |
|
RP ACT |
Off |
RP is not active. |
Green |
RP is active. |
|
FP STAT |
Off |
FP has not booted. |
Green |
FP is operational. |
|
Yellow |
FP has detected a fault. |
|
FP ACT |
Off |
FP is not active. |
Green |
FP is active. |
|
INSI ACT |
Off |
iNSI is not enabled. |
Green |
iNSI is enabled. |
|
ALRM |
Off |
No alarm condition is detected. |
Yellow |
Alarm condition is detected. |
|
RPLC |
Off |
Supervisor Card does not need to be replaced. |
White |
Supervisor Card needs to be replaced. |
LED |
Status |
Description |
---|---|---|
PIC_STAT |
Off |
The Supervisor PIC is not powered up. |
Green |
The Supervisor PIC is functioning normally. |
|
Yellow |
The Supervisor PIC has a fault. |
|
INSI_ACT |
Off |
iNSI module is not enabled. |
Green |
iNSI module is enabled. |
|
REPLACE |
Off |
The Supervisor PIC does not need to be replaced. |
Green |
The Supervisor PIC needs to be replaced. |
|
100G 0-1 |
Off |
The 100G backhaul port is not powered up or it is not in 100G mode. |
Yellow |
The 100G backhaul port is powered up and the link is down. |
|
Green |
The link is up with no active traffic. |
|
Blinking green |
The link is up with active traffic. |
|
10G 0-7 |
Off |
The 10G backhaul port is not powered up or it is not in 10G mode. |
Yellow |
The 10G backhaul port is powered up and the link is down. |
|
Green |
The link is up with no active traffic. |
|
Blinking green |
The link is up with active traffic. |
|
DTI Normal |
Off |
DTI is not in normal mode. |
Green |
DTI is in normal mode. |
|
Blinking green |
DTI is in normal mode as standby. |
|
DTI Fast |
Off |
DTI is not in fast mode. |
Yellow |
DTI is in fast mode. |
|
NME Lnk |
Off |
The Gigabit Ethernet link is down. |
Green |
The Gigabit Ethernet link is up. |
|
NME Act |
Off |
The Gigabit Ethernet link is down. |
Blinking yellow |
The Gigabit Ethernet link is up with active traffic. |
|
CM/DTP Lnk |
— |
Reserved for future use. |
CM/DTP Act |
— |
Reserved for future use. |
Monitoring the Supervisor 160G in the Cisco cBR Chassis Using LEDs
LED |
Status |
Description |
---|---|---|
PWR STAT |
Off |
Supervisor Card is not powered up. |
Green |
Supervisor Card is powered up. |
|
Yellow |
Supervisor Card has a power fault - at least one voltage rail exceeded its voltage threshold limit. |
|
Blinking green at a 2 seconds rate |
Supervisor Card has a power fault - less than the minimum number of fan modules with no fault condition detected at power-on. |
|
Blinking yellow at a 2 seconds rate |
Supervisor Card has a power fault - less than the minimum number of power modules with no fault condition detected at power-on. |
|
Blinking between green and yellow at a 2 seconds rate |
Supervisor Card has a power fault - the Supervisor PIC is not detected at power-on. |
|
Blinking yellow at a 1/4 second rate |
Supervisor Card has a power fault - either the Supervisor PIC, SUP-DC, or SUP-MB did not respond with a PGOOD signal within 3 seconds after power-on. |
|
Blinking green at a 1/4 second rate |
Software on the other Supervisor Card has turned off power on this Supervisor Card. |
|
Blinking between green and yellow at a 1/4 seconds rate |
Secure Boot authentication has failed and Supervisor Card is powered down. |
|
RP STAT |
Off |
RP has not booted. |
Blinking green |
Software is loading. |
|
Green |
RP is operational. |
|
Yellow |
RP has detected a fault. |
|
RP ACT |
Off |
RP is not active. |
Green |
RP is active. |
|
FP STAT |
Off |
FP has not booted. |
Green |
FP is operational. |
|
Yellow |
FP has detected a fault. |
|
FP ACT |
Off |
FP is not active. |
Green |
FP is active. |
|
INSI ACT |
Off |
iNSI is not enabled. |
Green |
iNSI is enabled. |
|
ALRM |
Off |
No alarm condition is detected. |
Yellow |
Alarm condition is detected. |
|
RPLC |
Off |
Supervisor Card does not need to be replaced. |
White |
Supervisor Card needs to be replaced. |
LED |
Status |
Description |
---|---|---|
PIC_STAT |
Off |
The Supervisor PIC is not powered up. |
Green |
The Supervisor PIC is functioning normally. |
|
Yellow |
The Supervisor PIC has a fault. |
|
INSI_ACT |
Off |
iNSI module is not enabled. |
Green |
iNSI module is enabled. |
|
REPLACE |
Off |
The Supervisor PIC does not need to be replaced. |
Green |
The Supervisor PIC needs to be replaced. |
|
SFP+ |
Off |
The SFP+ module is not powered up. |
Yellow |
The SFP+ module is powered up and the link is down. |
|
Green |
The link is up with no active traffic. |
|
Blinking green |
The link is up with active traffic. |
|
DTI Normal |
Off |
DTI is not in normal mode. |
Green |
DTI is in normal mode. |
|
Blinking green |
DTI is in normal mode as standby. |
|
DTI Fast |
Off |
DTI is not in fast mode. |
Yellow |
DTI is in fast mode. |
|
NME Lnk |
Off |
The Gigabit Ethernet link is down. |
Green |
The Gigabit Ethernet link is up. |
|
NME Act |
Off |
The Gigabit Ethernet link is down. |
Blinking yellow |
The Gigabit Ethernet link is up with active traffic. |
|
SSD |
Off |
There is no SSD access. |
Green |
SSD read/write is in progress. |
|
CM/DTP Lnk |
— |
Reserved for future use. |
CM/DTP Act |
— |
Reserved for future use. |