Specifications and Cables
This appendix provides system, port, and cabling specifications for the Cisco 836 and Cisco SOHO 96 series routers.
This chapter provides information on the following topics:
System Specifications
Table A-1 outlines the system specifications for the Cisco 836 and Cisco SOHO 96 series routers.
For information on regulatory compliance, refer to the Regulatory Compliance and Safety Information for Cisco 800 and SOHO Series Router document that shipped with your router.
Warning
Ultimate disposal of this product should be handled according to all national laws and regulations.
Port Connector Pinouts
This section provides pinouts for the following connectors:
•
ADSL—See Table A-2.
•
Console (for connecting a terminal or PC)—See Table A-3.
|
|
|
|
|
|---|---|---|---|
1 |
Unused |
1 |
Unused |
2 |
Unused |
2 |
Unused |
3 |
Ring |
3 |
Unused |
4 |
Tip |
4 |
Ring |
5 |
Unused |
5 |
Tip |
6 |
Unused |
6 |
Unused |
7 |
Unused |
||
8 |
Unused |
|
|
|
|
|---|---|---|
1 |
RTS |
8 |
2 |
DTR |
6 |
3 |
TXD |
2 |
4 |
GND |
5 |
5 |
GND |
5 |
6 |
RXD |
3 |
7 |
DSR |
4 |
8 |
CTS |
7 |
The console port is configured as a data communications equipment (DCE) device. The default parameters for the console port are as follows:
•
9600 baud
•
Eight data bits
•
No parity
•
One stop bit
Cabling Specifications
This section provides specifications for the following Ethernet cables, which you might need to provide:
•
Straight-through cables
•
Crossover cables
Ethernet Cable Specifications
Table A-4 lists the specifications for straight-through and crossover Ethernet cables.
|
|
|
|---|---|
10BASE-T |
Category 3 or 5 |
100BASE-T |
Category 5 or higher |
Maximum Cable Distance
Table A-5 provides the maximum distance of Ethernet and telephone cables that you can use to connect equipment to the router.
|
|
|
|---|---|
Ethernet cables |
328 ft (100 m) |