Messages and Recovery Procedures


This chapter lists and describes the Cisco IOS system error messages by facility for the Catalyst 4500 series switch. Within each facility, the messages are listed by severity levels 0 to 7. The highest severity level is 0, and the lowest severity level is 7. Each message is followed by an explanation and a recommended action, if one is available.

The system sends these error messages to the console (and, optionally, to a logging server on another system). Not all system error messages indicate problems with your system; some messages are purely informational, while other messages help diagnose problems with communication lines, internal hardware, or the system software.


Note The messages listed in this chapter do not include the date/time stamp designation; the date/time stamp designation is displayed only if the software is configured for system log messaging.



Note Writing to a module's serial EEPROM is not standard practice; when the module comes from the factory, the serial EEPROM is set to the correct values. We do not recommend that you change the factory defaults, because this action can cause the module to malfunction.


If the explanation that is provided for a given command does not sufficiently explain your problem and no recommended action is given, copy the error message exactly as it appears on the console or in the system log.

You should research and attempt to resolve the error using the Output Interpreter at this URL: https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl.

You can also enter the show tech-support command to gather additional information about the error. If the error message text, information from the Output Interpreter, or output from the show tech-support command do not help you solve the problem, contact your technical support representative and provide the representative with the information that you have gathered. For detailed information on how to contact your technical support  representative, see the "Obtaining Technical Assistance" section on page xiii.

ACL Messages

This section contains the access control list (ACL) message.

Error Message    C4K_ACL-4-OUTOFMEMORY:Out of Memory while allocating [char]

Explanation    The software failed to allocate memory for the given object while processing ACLs. The configuration might have exceeded its maximum limit. If so, the feature using this ACL will not work.

Recommended Action    If it is mandatory that the feature work normally, remove other unwanted features that require ACLs and retry the operation. If the problem persists, contact your technical support representative.

ARP Snooping Messages

This section contains the ARP snooping message.

Error Message    C4K_ARPSNOOPINGMAN-4-OUTOFRESOURCES: Resources for constructing ACLs 
are not available.

Explanation    Software resources are not available to setup hardware to redirect ARP packets to software. Dynamic ARP inspection will not work if this log message appears.

Recommended Action    Unconfigure other TCAM related features to reduce switch memory requirements and reconfigure the ACL.

BUFFERMANAGER Messages

This section contains the memory buffer management (BUFFERMANAGER) message.

Error Message    C4K_BUFFERMANAGER-3-OUTOFVBUFS: Have run out of vbufs (internal 
buffers)

Explanation    The switch ran out of the internal memory buffers that are used for various tasks. This error is unusual because the internal buffers are used for only a short time, released, and then available for reuse. Typically, this condition is transitory.

Recommended Action    If the message persists, reboot the switch.

CHASSIS Messages

This section contains the chassis (CHASSIS) messages.

CHASSIS-2

Error Message    C4K_CHASSIS-2-ALLCHASSISSEEPROMSINVALID: Contents of all chassis's 
serial eeproms are invalid

Explanation    The contents of all of the chassis's serial EEPROMs are invalid. In non-redundant chassis, there is one serial EEPROM, and it is bad. If this is a redundant chassis, there are two serial EEPROMs, and they are both bad.

Recommended Action    Try removing and reinserting the supervisor engine. If that doesn't work, try power cycling the switch. If the serial EEPROM is still invalid, this chassis should be returned.

Error Message    C4K_CHASSIS-2-SUPERVISORSEEPROMINVALID: Contents of supervisor's 
serial eeprom are invalid

Explanation    The contents of the supervisor engine's serial EEPROM are invalid. For example, a bad checksum or the supervisor engine type doesn't match with the other hardware information. This could happen if the read failed because the supervisor engine isn't seated correctly in the slot.

IOS considers this supervisor engine faulty and will not bring up the chassis' interfaces.

Recommended Action    Try removing and reinserting the supervisor engine. If that doesn't work, try power cycling the switch. If the switch still fails to come online, this supervisor engine should be returned.

Error Message    C4K_CHASSIS-2-INLINEPOWEROFF:Inline power to the switch has been 
turned off

Explanation    Software detected that the pass-through current is disabled. This condition will cause all phones drawing PoE from the switch to be powered off.

Recommended Action    If you want PoE, verify that the in-line power switch on the power supply is turned on.

Error Message    C4K_CHASSIS-2-INSUFFICIENTFANSDETECTED:Too few working fans in fan 
tray, the chassis will overheat. If not resolved, in 4 minutes all line cards will 
be placed into Reset-Mode

Explanation    Two or more fans in the system fan tray or power supplies are malfunctioning, or the fan tray has been removed. Although this is a minor alarm, system components could overheat and shut down.

Recommended Action    Replace the system fan tray or broken fans.

Error Message    C4K_CHASSIS-2-INSUFFICIENTFANSSHUTDOWN: Resetting linecards due to fan 
tray failure

Explanation    One or more required fans in the fan tray or the power supplies is malfunctioning. Software reset the modules to reduce heat generation.

Recommended Action    Replace the broken fans as soon as possible.

Error Message    C4K_CHASSIS-2-INSUFFICIENTPOWERDETECTED:Insufficient power available 
for the current chassis configuration

Explanation    The current chassis configuration exceeds power availability. If this condition persists, software will reset the modules.

Recommended Action    If the power availability problem persists and impacts performance, replace the power supply with a larger capacity power supply.

Error Message    C4K_CHASSIS-2-INSUFFICIENTPOWERSHUTDOWN:Holding module in slot [dec] 
in reset, due to insufficient power

Explanation    The switch was using more power than is available for the allowed time interval. Software reset the modules to reduce power consumption.

Recommended Action    If the power availability problem persists and impacts performance, replace the power supply with a power supply with a larger capacity.

Error Message    C4K_CHASSIS-2-OVERHEATINGSHUTDOWN:Resetting linecards due to critical 
temperature

Explanation    The switch is now warmer than its maximum allowable operating temperature. Software will reset modules to reduce heat generation.

Recommended Action    Verify that the switch is in the proper operating environment and that the fans are functioning properly.

CHASSIS-3

Error Message    C4K_CHASSIS-3-BADGBIC:Port [char]: Gbic's seeprom is bad, try 
reinserting: vendor: [char], p/n: [char], s/n: [char]

Explanation    A Gigabit Interface Converter (GBIC) with a serial EEPROM was detected in the port specified in the message. Although the serial EEPROM's contents were readable, the contents are not valid (possibly due to a bad checksum).

The message lists the vendor, part number, and serial number from the GBIC's serial EEPROM. This message appears if the GBIC is not seated correctly.

Recommended Action    Remove and reinsert the GBIC. If this message appears repeatedly, insert the GBIC in another port to verify that it is the GBIC and not the port that is bad. If the GBIC fails in a different port, return the GBIC to your technical support representative for reprogramming. If the GBIC works in the other ports but not in the original port, the original port is bad, and you need to return the module to your technical support representative for repair. To test the port further, insert a different GBIC into the port. If the other GBIC fails in that port, the port is bad.

Error Message    C4K_CHASSIS-3-BADMACRANGEINSPROM:Module [dec]'s serial eeprom 
contains [dec] mac addresses, but needs [dec]

Explanation    The contents of the module's serial EEPROM is incorrect, and the range is smaller than the number of front-panel ports for the module. The module's serial EEPROM contains a range of MAC addresses for this module, and the range should contain the same number of MAC addresses as the number of front-panel ports because each MAC address corresponds to a front-panel port.

Recommended Action    Contact your technical support representative; you will likely have to return the module to Cisco to reprogram the serial EEPROM.

Error Message    C4K_CHASSIS-3-CHASSISTYPEMISMATCHINSPROM: Supervisor's FPGA register 
chassis type is [char], but chassis' serial eeprom chassis type is [char]

Explanation    The chassis type in the supervisor engine's FPGA register doesn't match the type in the chassis' serial EEPROM.

Recommended Action    Check the chassis serial EEPROM information, using the show idprom chassis command. This should never happen in a production chassis. If it does, the chassis needs to be returned.

Error Message    C4K_CHASSIS-3-CLOCKMODULESEEPROMINVALID: Invalid Clock Module seeprom 
data

Explanation    A failure occurred while reading the clock module serial EEPROM. This message should occur only in a prototype switch used in an early field trial.

Recommended Action    Contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_CHASSIS-3-DAUGHTERCARDSEEPROMREADFAILED:Failed to read the serial 
eeprom on module [dec], daughter card [dec]

Explanation    The serial EEPROM for a daughter card on the specified module is unreadable. Because reading this EEPROM is the only way to determine the type of card, the card remains offline, as if it was not installed on the module.

Recommended Action    Remove the module, and then remove and reseat the daughter card in the module. If this message reappears after you reinsert the module into the switch, the serial EEPROM might be bad. Contact your technical support representative; you will likely have to return the module to Cisco to reprogram or replace the serial EEPROM.

Error Message    C4K_CHASSIS-3-FANTRAYSEEPROMINVALID: Invalid fan tray seeprom data

Explanation    A failure occurred while reading the system fan tray serial EEPROM. This message should occur only in a prototype switch used in an early field trial.

Recommended Action    Reseat the fan tray to see if the message is due to a faulty connection. If it persists, contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_CHASSIS-3-FIRSTCHASSISSEEPROMINVALID: Contents of chassis's first 
serial eeprom are invalid

Explanation    The contents of the chassis's first serial EEPROM are invalid. This message only appears in a redundant chassis, which means there is a second serial EEPROM.

Recommended Action    Try power cycling the switch. If the serial EEPROM is still invalid, this chassis should be returned.

Error Message    C4K_CHASSIS-3-GBICSEEPROMREADFAILED:Failed to read gbic serial eeprom 
on port [char], try reinserting

Explanation    A Gigabit Interface Converter (GBIC) was detected in the specified port, but the contents of the GBIC's EEPROM was unreadable. The EEPROM must be read to determine the GBIC type. The read might fail if the GBIC is not seated correctly.

Recommended Action    Remove and reinsert the GBIC. If this message reappears, insert the GBIC in another port to verify that it is the GBIC and not the port that is bad. If the GBIC fails in the other port, return the GBIC to your technical support representative for reprogramming. If the GBIC works in the other ports but not in the original port, the original port is bad, and you need to return the module to your technical support representative for repair. To test the port further, insert a different GBIC into the port. If the other GBIC also fails in that port, the port is bad.

Error Message    C4K_CHASSIS-3-INCOMPATIBLETRANSCEIVERINSERTED: Port [char]: New 
transceiver inserted is incompatible for this module.

Explanation    The inserted transceiver is not compatible with the switching module. The release notes contain a list of supported transceivers for this module.

Recommended Action    Remove this transceiver from the port if it is incompatible with this module. If it is a supported transceiver, it may need to be replaced.

Error Message    C4K_CHASSIS-3-INSUFFICIENTPOWER:Insufficient power to bring up module 
in slot [dec]

Explanation    The module type was identified, but the switch does not have sufficient power to bring the module up. The switch holds the module in reset mode to consume less power.

Recommended Action    Add or replace a power supply to expand the power capacity of the chassis.

Error Message    C4K_CHASSIS-3-INSUFFICIENTPOWERSUPPLIESDETECTED:
Insufficient power supplies present for specified configuration

Explanation    The system software detected that the current chassis configuration has fewer power supplies than required for the existing configuration.

Recommended Action    Add a power supply to meet the needs of the current chassis configuration.

Error Message    C4K_CHASSIS-3-INVALIDMGMTETHERNETADDR: Chassis SPROM not set or 
invalid MAC address range

Explanation    The out of band management port uses a MAC address from the system's MAC address range. The contents of the system's SPROM are bad, so the out of band management port does not have a MAC address.

Recommended Action    Contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_CHASSIS-3-LINECARDMUXBUFFERTOSUPALIGNMENTWRONG:Linecard [dec] 
MuxBuffers aligned towards supervisor in slot [dec] instead of [dec]

Explanation    The mux buffers that work with the switching module in the mentioned slot are configured to work with the standby supervisor engine. The switching module is completely unusable in this condition.

Recommended Action    Try removing and reinserting the affected switching module. If that doesn't work, try resetting the switch. If the problem persists, contact your technical support representative.

Error Message    C4K_CHASSIS-3-MIXINVOLTAGEDETECTED:Power supplies in the chassis are 
receiving different voltage inputs

Explanation    All the inputs to a chassis must be at the same voltage. Mixed voltage inputs are not supported.

Recommended Action    Change the power supplied to the switch so that all inputs to the chassis are of the same type.

Error Message    C4K_CHASSIS-3-MUXBUFFERSEEPROMINVALID: Invalid data in mux buffer 
[dec]'s serial eeprom

Explanation    The mux buffer serial EEPROM could not be read or has not been programmed.This message should occur only in a prototype switch used in an early field trial.

Recommended Action    Reseat the mux buffers to see if the message is due to a faulty connection. If it persists, contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_SUPERVISOR-3-MUXMAYMISALIGN:Linecard Mux-buffers may mis-align to 
incorrect supervisor due to reset with other supervisor desires to be active

Explanation    While resetting the switching modules and taking them out of reset the other supervisor engine is trying to become active using hardware hot-standby logic. This may cause incorrect alignment of the switching module mux-buffers to use the non-active supervisor engine, and the switch will not be able to pass traffic until the alignment is reset.

Recommended Action    Reset the other supervisor engine using the redundancy reload peer command, and contact your technical support representative to report the failure.

Error Message    C4K_CHASSIS-3-LINECARDNOTVALIDINSLOT: Module (Field Replaceable Unit 
minor type [dec]) is not supported in slot [dec]

Explanation    The supervisor engine identified the type, but the switching module cannot be supported in this slot due to the insufficient number of backplane ports in this slot.

Recommended Action    This is an informational message only. No action is required. If possible, move the switching module to another slot, and use a supported module in the original slot.

Error Message    C4K_CHASSIS-3-LINECARDSEEPROMREADFAILED:Failed to read module [dec]'s 
serial eeprom, try reinserting module

Explanation    The switch cannot read the serial EEPROM of the specified module, and the module will not boot because the EEPROM failed to identify the module type. The read might fail if the module is not seated correctly in the slot.

Recommended Action    Remove and reinsert the module. If this message reappears, reboot the switch. If the problem persists, contact your technical support representative. You will likely have to return the module to Cisco to reprogram or replace the serial EEPROM.

Error Message    C4K_CHASSIS-3-LINECARDSEEPROMWRITEFAILED:Failed to write module 
[dec]'s serial eeprom

Explanation    A write operation to the serial EEPROM failed. The write might fail if the module is not seated correctly in the slot.

Recommended Action    Remove and reinsert the module. If this message reappears, reboot the switch. If the problem persists, contact your technical support representative. You will likely have to return the module to Cisco to reprogram or replace the serial EEPROM.

Error Message    C4K_CHASSIS-3-MIXINPOWERDETECTED:Power supplies in the chassis are of 
different types (AC/DC) or wattage

Explanation    The software detected different kinds of power supplies in the chassis. In a Catalyst 4006 chassis, the power values default to the wattage of the weakest power supply. If you mix power supplies in a Catalyst 4500 series chassis, the switch will use the power supply in power supply bay 1 (PS1) and ignore the power supply in power supply bay 2 (PS2). We do not recommend mixing power supplies of different wattages.

Recommended Action    Verify that both power supplies are the same kind and wattage. Replace a power supply if necessary.

Error Message    C4K_CHASSIS-3-MIXINVOLTAGEDETECTED:Power supplies in the chassis are 
receiving different voltage inputs

Explanation    All the inputs to a chassis must be at the same voltage. Mixed voltage inputs are not supported.

Recommended Action    Replace one of the power supplies so that the power supplies used are of the same model.

Error Message    C4K_CHASSIS-3-MODULENOTSUPPORTHALF:Module [dec] does not support 10 Mb 
or 100Mb Half duplex operation. Please have your card upgraded if you need half 
duplex operation.

Explanation    Some preproduction switching modules have interfaces that do not work in half-duplex mode. This module is probably a prototype.

Recommended Action    Contact your technical support representative; you will likely have to return the module to Cisco.

Error Message    C4K_CHASSIS-3-OLDWSX4124: WS-X4124-FX-MT revision [dec].[dec], which 
is < 1.6, is not supported

Explanation    WS-X4124-FX-MT modules with revisions < 1.6 are not supported.

Recommended Action    This module needs to be replaced with a WS-X4124-FX-MT module that has a newer hardware revision number.

Error Message    C4K_CHASSIS-3-ONLYLXSFPSALLOWED:Port [char] has a non-LX SFP, which is 
not supported

Explanation    The WS-X4448-GB-LX module supports only LX SFPs. It marks any other type of Small Form-Factor Pluggable (SFP) as faulty.

Recommended Action    Replace the SFP with an LX SFP that Cisco supports.

Error Message    C4K_CHASSIS-3-OUTOFMEMORY:Ran out of memory - cannot allocate internal 
buffers

Explanation    The switch ran out of memory in the temporary buffers.

Recommended Action    If this message reappears, reboot the switch.

Error Message    C4K_CHASSIS-3-POWERSUPPLYSEEPROMINVALID: Invalid data in power supply 
[dec]'s serial eeprom

Explanation    The power supply serial EEPROM could not be read or has not been programmed.

Recommended Action    Try re-inserting the power supply. If that doesn't work, replace it with a new power supply.

Error Message    C4K_CHASSIS-3-SEEPROMREADFAILEDAFTERWRITE:Error reading back module 
[dec]s serial EEPROM data after write

Explanation    After writing a module's serial EEPROM in response to a CLI request, the switch tried to read it back in, to ensure that the correct values were written out. What the switch read back in differs from what the switch wrote out. The read or write might fail if the module is not seated correctly in the slot.

Recommended Action    Remove and reinsert the module. If that does not work, reboot the switch. If the problem persists, contact your technical support representative. You will likely have to return the module to Cisco to reprogram or replace the serial EEPROM.


Note Writing the module's serial EEPROM is not standard practice; when the module comes from the factory, its serial EEPROM is set to the correct values. We do not recommend that you change the factory defaults, because this action could cause the module to malfunction.


Error Message    C4K_CHASSIS-3-SFPCRCINTEGRITYCHECKFAILED:SFP integrity check on port 
[char] failed: bad crc

Explanation    The checksum of the SFP SEEPROM is not valid, indicating a bad or non-Cisco SFP.Only Cisco-qualified Small Form-factor Pluggables (SFPs) are supported. Other SFPs place the associated port in a faulty status.

Recommended Action    Replace the SFP with an SFP that Cisco supports.

Error Message    C4K_CHASSIS-3-SFPINTEGRITYCHECKFAILED:SFP integrity check on port 
[char] failed: bad key

Explanation    Only Cisco-qualified Small Form-factor Pluggables (SFPs) are supported. Other SFPs place the associated port in a faulty status.

Recommended Action    Replace the SFP with an SFP that Cisco supports.

Error Message    C4K_CHASSIS-3-SFPSERIALINTEGRITYCHECKFAILED:SFPs on ports [char] and 
[char] have duplicate serial numbers

Explanation    Only Cisco-qualified Small Form-factor Pluggables (SFPs) are supported. Other SFPs place the associated port in the faulty status.

All SFPs must have a unique serial number. If this message appears you likely have a cloned SFP SEEPROM.

Recommended Action    Replace the SFP with an SFP that Cisco supports.

Error Message    C4K_CHASSIS-3-STUBPHYMISMATCH: Stub type mismatch: stub [dec]/[dec] is 
type [dec], should be type [dec]

Explanation    The stubs have non-matching physical types for the specified module.

Recommended Action    Verify that the physical types for every stub on the module match.

Error Message    C4K_CHASSIS-3-SUPERVISORTYPEMISMATCHINSPROM: Supervisor's FPGA 
register type is [dec], but supervisor's serial eeprom type is [dec]

Explanation    The type in the supervisor engine's FPGA register doesn't match the type in the supervisor engine's serial EEPROM. This might happen if the IDPROM is misprogrammed or the supervisor engine's FPGA register somehow returns an incorrect value. Both are extremely unlikely.

Recommended Action    Check the FruMinorType field in the supervisor engine's serial EEPROM, using the show idprom supervisor command. The output should be the same as the number printed in this log message for the FPGA register type. This should never happen with a production supervisor engine. If it does, replace the supervisor engine.

Error Message    C4K_CHASSIS-3-TEMPERATURESENSORREADFAILED: Failed to read the 
supervisor temperature sensor

Explanation    The temperature sensor on the supervisor engine cannot be read. If the chassis becomes overheated, this condition will not be reported.

Recommended Action    If this message appears only once, this error could be transient and no action is required. If this message appears repeatedly (once every 30 minutes), inspect and, if necessary, replace the temperature sensor on the supervisor engine.

Error Message    C4K_CHASSIS-3-UNKNOWNLINECARD:Unknown module (Field Replaceable Unit 
minor type [dec]) in slot [dec]

Explanation    The module's serial EEPROM was readable, and your software image does not recognize this module. A software upgrade is necessary.

Recommended Action    Upgrade the software to a version that is compatible with the module.

CHASSIS-4

Error Message    C4K_CHASSIS-4-CANTWRITESUPERVISORSPROM:Writing the supervisor's SPROM 
is not supported

Explanation    Rewriting the supervisor engine's serial programmable read-only memory (SPROM) is not allowed, because if it is done incorrectly, it could make the system unusable.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_CHASSIS-4-INLINEPOWERRESTORED:Resuming normal phone operation 
since inline power has been restored

Explanation    PoE to the switch was restored, and normal phone operation will resume.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_CHASSIS-4-OVERHEATINGOVER:Resuming normal operation after return 
to acceptable temperatures.

Explanation    The unit's modules were reset to reduce heat generation, because the unit reached a critical temperature. The switch is now cool enough to return to normal operation.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_CHASSIS-4-SUFFICIENTFANSRESTORED: Resuming normal operation after 
restoration of adequate fan cooling

Explanation    The modules were reset to reduce heat generation because there were not enough working fans. Adequate fan cooling is now restored, and the switch will resume normal operation.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_CHASSIS-4-SUFFICIENTMODULEPOWERRESTORED:Module in slot [dec] 
resuming normal operation after restoration of adequate power

Explanation    The module was reset to conserve power because the system had inadequate power available. The switch now has adequate power and is resuming normal operation.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_CHASSIS-4-SUFFICIENTPOWERRESTORED:Resuming normal operation after 
restoration of adequate power

Explanation    The switch reset the modules to conserve power, but it now has adequate power and will resume normal operation.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_CHASSIS-4-TDRTESTINPROGRESS: TDR test is in progress on interface 
[char]

Explanation    The TDR test is already in progress on this interface.

Recommended Action    Try the command again after the test is completed.

Error Message    C4K_CHASSIS-4-TESTNOTSUPPORTEDONPORT: [char] is not supported on this 
port

Explanation    The online diagnostic test requested cannot be run on the specified port.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_CHASSIS-4-TESTNOTSUPPORTEDONPORTCONNECTOR: [char] is not 
supported on port connector type: [char]

Explanation    This online diagnostic test cannot be run on the specified port with the current connector type. If the connector type changes to copper, it may be possible to run the test.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_CHASSIS-4-UNSUPPORTEDTRANSCEIVER: Unsupported transceiver found 
in [char]

Explanation    The transceiver was identified as an unsupported non-Cisco transceiver.

Recommended Action    If this transceiver was purchased from Cisco, contact Cisco TAC to get the transceiver replaced.

CHASSIS-5

Error Message    C4K_CHASSIS-5-POEHEALTHCHECKFAILED: Poe Health Check failed on slot [dec] (count = [dec])

Explanation    PoE health check has failed on a module. The PoE service provided by the module may be unavailable.

Recommended Action    If the message shows up rarely and coincides with external events such as input power supplies being changed, this message can be safely ignored. If the message shows up continuously, please contact your Cisco representative for a replacement of the module.

CHASSIS-7

Error Message    C4K_CHASSIS-7-GBICINSERTED:Port [char]: New gbic inserted: vendor: 
[char], p/n: [char], s/n: [char]

Explanation    A Gigabit Interface Converter (GBIC) with a serial EEPROM was detected in the specified interface. The message lists the vendor, part number, and serial number from the GBIC's serial EEPROM.

Recommended Action    This is an informational message only. No action is required.

COMMONHWACLMAN Messages

This section contains the common hardware ACL management (COMMONHWACLMAN) messages.

COMMONHWACLMAN-4

Error Message    C4K_COMMONHWACLMAN-4-ALLACLINHW:All configured ACLs now fully loaded 
in hardware TCAM -  hardware switching / QoS restored 

Explanation    All ACL-based features are now successfully loaded. Packets that were previously processed in software due to the prior loading failure will now be processed in hardware.


Note If the features were policy maps, then QoS will be reenabled on all applicable interfaces.


Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_COMMONHWACLMAN-4-FAILEDTOSWITCHPORTTAGS:Failed to switch port 
tags, old tag: [object-info] new tag: [object-info] . Software paths: [dec] 
Hardware paths: [dec]

Explanation    The software failed to switch tags. This error could be transient. The ACL that you were trying to configure will not become active.

Recommended Action    Detaching and reattaching the ACLs (and policies) might solve the problem.

Error Message    C4K_COMMONHWACLMAN-4-FAILEDTOSWITCHVLANTAGS:Failed to switch vlan 
tags, old tag: [object-info] new tag: [object-info] . Software paths: [dec] 
Hardware paths: [dec]

Explanation    The software failed to switch tags. This error could be transient. The ACL that you were trying to configure will not become active.

Recommended Action    Detaching and reattaching the ACLs (and policies) might solve the problem.

Error Message    C4K_COMMONHWACLMAN-4-HWPROGSUCCESS: [char] [char] - now fully loaded 
in hardware TCAM

Explanation    ACL-based features are now successfully loaded. Packets that were previously processed in software due to a prior loading failure will now be processed in hardware. If the feature is a policy map, then QOS will be reenabled on the specific interface.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_COMMONHWACLMAN-4-OUTOFPATHS: Could not allocate path for 
( [object-info] )

Explanation    There are too many ports or VLANs using ACLs. The ACLs might not work correctly.

Recommended Action    Remove unnecessary ACLs from some interfaces.

Error Message    C4K_COMMONHWACLMAN-4-OUTOFTAGS:No more free tags available for path 
( [object-info] )

Explanation    All available tags are being used or are about to be used. Because you have configured either too many features using ACLs or features using ACLs that are attached to ports or VLANs, the hardware forwards the packets to CPU for ACL processing.

Recommended Action    Remove unnecessary ACLs from some interfaces.

Error Message    C4K_COMMONHWACLMAN-4-PERMITALL: Out of resources for Qos, permit all 
for  [object-info]

Explanation    The switch is running out of hardware CAM resources. All packets are permitted, and QoS is applied.

Recommended Action    Remove unnecessary ACLs from some interfaces.

Error Message    C4K_COMMONHWACLMAN-4-PORTBASEDACLSDISABLED: Output Port Acl  [char]  
has been disabled on port  [char]

Explanation    The output port ACL is disabled on the interface because there are not enough hardware resources or there are ACEs that require CPU processing of packets.

The port ACL is disabled and displays a warning message because the software cannot handle the output port ACLs.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_COMMONHWACLMAN-4-PUNTTOSOFTWARE:Out of resources, punt packets to 
sw for [object-info]

Explanation    The hardware content-addressable memory (CAM) resources have been depleted. The hardware forwards the packets to the software for ACL processing.

Recommended Action    Remove unnecessary ACLs from some interfaces.

COMMONSTUBMAN Messages

This section contains the Catalyst 4500 series ASIC-specific messages.

C4K_COMMONSTUBMAN-4

Error Message    C4K_COMMONSTUBMAN-4-DIAGSFAILED: [char] failed diagnostics

Explanation    An ASIC in slot [char] failed diagnostics.

Recommended Action    Contact your technical support representative.

Error Message    C4K_COMMONSTUBMAN-4-FAILEDTOSENDLOOPBACKTRIES: [char] port [dec] 
failed to send packet in [dec] tries

Explanation    An ASIC in slot [char] was unable to send a loopback packet on port [dec] and this is the [dec]th time it tried to send and failed. This suggests that the switch is out of memory. The software will attempt to send a loopback packet only three times.

Recommended Action    Contact your technical support representative.

Error Message    C4K_COMMONSTUBMAN-4-UNEXPECTEDLOOPBACK: [char] sent out a loopback 
packet on port [dec], but it came back on port [dec]

Explanation    The ASIC diagnostics for slot [char] sent a loopback packet out port [dec] and it came back on another port [dec]. This is unexpected because the loopback is done within the hardware.

Recommended Action    Contact your technical support representative.

C4K_COMMONSTUBMAN-7

Error Message    C4K_COMMONSTUBMAN-7-LOSTPACKET: [char] port [dec] lost a packet

Explanation    A loopback packet was lost during online diagnostics of an ASIC in slot [char].

Recommended Action    This is an informational message only. No action is required.

DHCP_SNOOPING Messages

This section contains the DHCP snooping (DHCP_SNOOPING) messages.

DHCP_SNOOPING-3

Error Message    DHCP_SNOOPING-3-DHCP_SNOOPING_INTERNAL_ERROR: DHCP Snooping internal 
error

Explanation    A software sanity check failed in the DHCP snooping process.

Recommended Action    This is an informational message only. No action is required.

DHCP_SNOOPING-4

Error Message    DHCP_SNOOPING-4-AGENT_OPERATION_FAILED_N: DHCP snooping binding 
transfer failed([dec]). [chars]

Explanation    This message is logged once every 30 minutes and displays the [dec] number of failures that occurred for a given reason [chars] during the past 30 minutes.

This message is a rate-limited version of the DHCP_SNOOPING-4-AGENT_OPERATION_FAILED message.

Recommended Action    Based on the reason for the error [chars], look at the explanation for the DHCP_SNOOPING-4-AGENT_OPERATION_FAILED message, and take the appropriate action.

Error Message    DHCP_SNOOPING-4-AGENT_OPERATION_FAILED: DHCP snooping binding 
transfer failed. Unable to access URL.

Explanation    The DHCP snooping binding transfer failed. The reason for failure can include any of the following:

–The URL is not available to use.

–Not enough memory is available for creating an agent.

–The number of agents reached the maximum supported limit.

–The switch is unable to create an agent.

–The switch is unable to access the URL.

–The switch is unable to start the agent.

–The Abort timer expired.

–The number of entries exceeded the maximum supported limit.

–An error occurred when reading the remote database.

–An error occurred while writing to the remote database.

–DHCP snooping expected more data during the read.

–The string type is invalid.

–The version string type is invalid.

–DHCP snooping is expecting a new line in the database.

–'TYPE' was not found in the remote database.

–'VERSION' was not found in the remote database.

–'BEGIN' was not found in the remote database.

–'END' was not found in the remote database.

–The type string was not found in the remote database.

–The version string was not found in the remote database.

–The checksum failed upon entry into the remote database.

Recommended Action    Based on the reason for the error (listed above), take the appropriate action.

Error Message    DHCP_SNOOPING-4-DHCP_SNOOPING_DATABASE_FLASH_WARNING: Saving DHCP 
snooping bindings to [char] can fill up your device causing  the writes of bindings 
to device

Explanation    Saving DHCP snooping bindings to a flash file system such as bootflash or slot0 could cause the flash to fill up. Possible consequences include a long delay to regain a console connection, write failures for database configurations, regular squeeze requirements, and reduced life of flash due to regular squeeze operations.

Recommended Action    Save the DHCP snooping bindings to an alternate destination. Possible locations for the database agent include a TFTP or FTP server. Please see the command line help for a complete list of options.

Error Message    DHCP_SNOOPING-4-DHCP_SNOOPING_ERRDISABLE_WARNING: DHCP Snooping 
received [dec] DHCP packets on interface [char]

Explanation    DHCP snooping detected a DHCP packet rate-limit violation on the specified interface. The interface will be placed in the errdisable state.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-4-DHCP_SNOOPING_PVLAN_WARNING: DHCP Snooping 
configuration may not take effect on secondary  vlan [dec]. [char]

Explanation    DHCP snooping configuration on the primary VLAN automatically propagates to all secondary VLANs if private VLANs are enabled.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-4-IP_SOURCE_BINDING_PVLAN_WARNING: IP source filter may 
not take effect on secondary  vlan [dec] where IP source binding is configured. 
[char]

Explanation    The IP source filter on the primary VLAN automatically propagates to all secondary VLANs if private VLANs are enabled.

Recommended Action    Reconfigure the IP source binding to a known functioning VLAN.

Error Message    DHCP_SNOOPING-4-IP_SOURCE_BINDING_NON_EXISTING_VLAN_WARNING: IP 
source binding is configured on non existing vlan [dec].

Explanation    IP source binding was configured on a VLAN that has not yet been configured.

Recommended Action    This is an informational message only. No action is required. It may persist unless you define the VLAN in question and then reapply the IP source binding. If you see this message regarding a VLAN that is correctly configured, contact your technical support representative.

Error Message    DHCP_SNOOPING-4-NTP_NOT_RUNNING: NTP is not running; reloaded binding 
lease expiration  times are incorrect.

Explanation    If the DHCP snooping bindings are loaded by the DHCP snooping database agent and NTP is not running, then the calculated lease duration for the bindings will be incorrect.

Recommended Action    Configure NTP on the switch to provide an accurate time and date for the system clock. Then disable and re-enable DHCP snooping to clear the bindings database.

Error Message    DHCP_SNOOPING-4-QUEUE_FULL: Fail to enqueue DHCP packet into 
processing queue: [char]

Explanation    DHCP packets are coming into the CPU at a much higher rate than the DHCP snooping process can handle them. These unhandled DHCP packets will be dropped to prevent a denial of service attack.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-4-SSO_SYNC_ACK_ERROR:Error is encountered in processing 
acknowledgement for DHCP  snooping binding sync [char]. ack message txn id:[hex]

Explanation    There was an error in handling the DHCP synchronization acknowledgement. In most of these cases, the ACK message is ignored.

Recommended Action    This is an informational message only. No action is required.

Error Message    IP_SOURCE_GUARD-4-DENY_INVALID_PACKET: Detected and dropped illegal traffic on port [char] and vlan [dec] the non-cumulative packet dropped count is [dec]. 

Explanation    IP Source Guard only permits traffic with the correct source IP to MAC binding on the port or VLAN. There may be a malicious host trying to carry out a denial of service attack using another host's source address. The illegal traffic is dropped bythe IP Source Guard feature with no appreciable impact to performance.

Recommended Action    Identify the source of the illegal traffic and stop it.

Error Message    DHCP_SNOOPING-4-STANDBY_AGENT_OPERATION_FAILED: DHCP snooping binding 
transfer failed on the Standby Supervisor. [char]

Explanation    If the DHCP snooping database supporting SSO is configured as a local device, both supervisor engines will update their database whenever there is an update regarding bindings. This error message is an indication that a snooping database update on the standby supervisor engine failed in the manner mentioned. The most likely cause for these problems is if the snooping database is configured as a slot0 device, but functioning compact flash memory is only present on the active supervisor engine's slot0 while the standby supervisor engine's slot0 is empty or faulty. Possible variations in output include:

"URL not available for use."

"Not enough memory available for creating agent."

"Number of agents reached maximum supported limit."

"Unable to create agent."

"Unable to access URL."

"Unable to start agent."

"Abort timer expiry."

"Number of entries exceeded max supported limit."

"Unable to transfer bindings. Memory allocation failure."

"Error reading the remote database."

"Error writing to remote database."

"Expected more data on read."

"Type string invalid."

"Version string invalid."

"New line expected in database."

"\'TYPE\' not found in remote database."

"\'VERSION\' not found in remote database."

"\'BEGIN \' not found in remote database."

"\'END\' not found in remote database."

"Type string not found in remote database."

"Version string not found in remote database."

"Checksum failed on an entry in remote database."

"No failure recorded."

Recommended Action    The switch will continue to function if no action is taken, but the redundancy features will be compromised until both active and standby supervisor engines have working flash memory available. Replace or insert flash memory into the supervisor engine that lacks it if needed.

DHCP_SNOOPING-5

Error Message    DHCP_SNOOPING-6-AGENT_OPERATION_SUCCEEDED: DHCP snooping database 
[char] succeeded. 

Explanation    DHCP snooping has successfully read from or written to the database.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-5-DHCP_SNOOPING_FAKE_INTERFACE: [char] drop message 
with mismatched source interface  the binding is not updated message type: [char] 
MAC sa: [mac-addr]

Explanation    The DHCP snooping feature has detected a host trying to carry out a denial of service attack on another host in the network. The packet will be dropped.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-5-DHCP_SNOOPING_MATCH_MAC_FAIL: [char] drop message 
because the chaddr doesn't  match source mac message type: [char] chaddr: 
[mac-addr] MAC sa: [mac-addr]

Explanation    The DHCP snooping feature attempted MAC address validation and the check failed. There may be a malicious host trying to carry out a denial of service attack on the DHCP server. The packet will be dropped.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-5-DHCP_SNOOPING_NONZERO_GIADDR: [char] drop message 
with non-zero giaddr or option82 value  on untrusted port message type: [char] MAC 
sa: [mac-addr]

Explanation    The DHCP snooping feature discovered a DHCP packet with option values not allowed on the untrusted port, indicating some host may be trying to act as a DHCP relay or server. The packet will be dropped.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-5-DHCP_SNOOPING_UNTRUSTED_PORT: [char] drop message on 
untrusted port message type: [char]  MAC sa: [mac-addr]

Explanation    The DHCP snooping feature discovered certain types of DHCP messages not allowed on the untrusted interface, indicating some host may be trying to act as a DHCP server. The packet will be dropped.

Recommended Action    This is an informational message only. No action is required.

DHCP_SNOOPING-6

Error Message    DHCP_SNOOPING-6-AGENT_OPERATION_SUCCEEDED: DHCP snooping database 
[char] succeeded. 

Explanation    DHCP snooping has successfully read or written to the database.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-6-BINDING_COLLISION: Binding collision. [dec] bindings 
ignored

Explanation    One or more bindings from the database file has a MAC address and VLAN combination for which the switch already holds DHCP snooping bindings.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-6-INTERFACE_NOT_VALID: Interface not valid. [dec] 
bindings ignored.

Explanation    The interface that is listed in the database file's binding is not available, that the interface is a router port, or that the interface is a DHCP snooping-trusted Layer 2 interface.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-6-LEASE_EXPIRED: Lease Expired. [dec] bindings ignored. 

Explanation    The DHCP lease expired for the given number of bindings from the database file.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-6-PARSE_FAILURE: Parsing failed for [dec] bindings.

Explanation    The database read operation failed for the stated number of bindings.

Recommended Action    This is an informational message only. No action is required.

Error Message    DHCP_SNOOPING-6-VLAN_NOT_SUPPORTED: Vlan not supported. [dec] bindings 
ignored. 

Explanation    The VLAN is not supported by DHCP snooping.

Recommended Action    This is an informational message only. No action is required.

DOT1X (802.1X) Messages

This section contains the IEEE 802.1X-related (DOT1X) port-based authentication messages.

DOT1X-4

Error Message    DOT1X-4-MEM_UNAVAIL:Memory was not available to perform the 802.1X 
action

Explanation    Due to a lack of memory 802.1X cannot perform authentication, so it will not be enabled.

Recommended Action    Reduce other system activity to ease memory demands. Install more memory, if necessary.

Error Message    DOT1X-4-MSG_ERR: Unknown message event received

Explanation    Due to an unexpected event the 802.1X process received an unknown message.

Recommended Action    Restart 802.1X by entering the dot1x system-auth-control command in case the condition is transient. If the restart fails, reload the device.

Error Message    DOT1X-4-PROC_START_ERR: DOT1X unable to start

Explanation    For unknown reasons 802.1X cannot start.

Recommended Action    Restart 802.1X by entering the dot1x system-auth-control command in case the condition is transient. If the restart fails, reload the device.

Error Message    DOT1X-4-UNKN_ERR: An unknown operational error occurred

Explanation    Due to an unexpected internal error 802.1X cannot operate.

Recommended Action    Reload the device.

DOT1X-5

Error Message    DOT1X-5-ERR_CHANNELLING: Dot1x can not be enabled on Channelling ports

Explanation    Dot1x could not be enabled on the channelling port. This condition was caused by trying to set Dot1x port-control to auto or force-unauthorized (Force_unauth) mode on a channelling port, which is not allowed.

Recommended Action    Disable channeling on the interface, and then enable 802.1X.

Error Message    DOT1X-5-ERR_VVID_NOT_SUPPORTED: Dot1x can not be enabled on this port 
with Voice VLAN configured.

Explanation    Dot1x with voice VLAN is not supported on this port on this platform.

Recommended Action    Remove the voice VLAN configuration on this port and retry the Dot1x operation.

Error Message    DOT1X-5-ERR_DYNAMIC: Dot1x can not be enabled on Dynamic ports

Explanation    Dot1x could not be enabled on the Dynamic mode port. This condition was caused by trying to set Dot1x port-control to auto or force-unauthorized (Force_unauth) mode on a dynamic mode port, which is not allowed.

Recommended Action    Disable the dynamic mode on the interface, and then enable 802.1X.

Error Message    DOT1X-5-ERR_DYNAMIC_VLAN: Dot1x can not be enabled on dynamic VLAN 
ports.

Explanation    Dot1x could not be enabled on the Dynamic VLAN port. This condition was caused by trying to set Dot1x port-control to auto or force-unauthorized (Force_unauth) mode on a dynamic VLAN port, which is not allowed.

Recommended Action    Disable the dynamic VLAN on the interface, and then enable 802.1X.

Error Message    DOT1X-5-ERR_INVALID_AAA_ATTR: Got invalid AAA attribute settings 
[char] 

Explanation    The authorization settings obtained are either unsupported or invalid.

Recommended Action    Change the value to reflect the correct settings.

Error Message    DOT1X-5-ERR_INVALID_TUNNEL_MEDIUM_TYPE: Got an invalid value [char] 
for TUNNEL_MEDIUM_TYPE [char] 

Explanation    The provided TUNNEL_MEDIUM_TYPE is either unsupported or invalid.

Recommended Action    Change the value to reflect the correct tunnel medium type.

Error Message    DOT1X-5-ERR_INVALID_TUNNEL_TYPE: Got an invalid value of [char] for 
TUNNEL_TYPE [char] 

Explanation    The provided TUNNEL_TYPE is either unsupported or invalid.

Recommended Action    Change the value to reflect the correct tunnel type.

Error Message    DOT1X-5-ERR_MULTI_ACCESS:Dot1x can not be enabled on voice vlan 
configured ports.

Explanation    802.1X cannot be enabled on a voice VLAN-configured port. This condition is caused by trying to set 802.1X port control to auto or force-unauthorized (force_unauth) mode on a voice VLAN-configured port, which is not allowed.

Recommended Action    Disable voice VLAN on the interface, and then enable 802.1X.

Error Message    DOT1X-5-ERR_PER_USR_IP_ACL: Applied per-user IP ACL was unsuccessful 
on interface [char]

Explanation    Dot1x could not successfully apply per-user IP ACL, one possible cause could be an invalid pub from the RADIUS server.

Recommended Action    Reconfigure the RADIUS pub.

Error Message    DOT1X-5-ERR_PER_USR_MAC_ACL: Applied per-user MAC ACL was unsuccessful 
on interface [char] 

Explanation    802.1X cannot successfully apply a per-user MAC ACL possibly because of an invalid pub from the RADIUS server.

Recommended Action    Examine the RADIUS pub and configure a correct one.

Error Message    DOT1X-5-ERR_PROTO_TUNNELLING:Dot1x can not be enabled on protocol 
tunnelling enabled ports.

Explanation    802.1X cannot be enabled on the protocol tunneling-enabled port. This condition is caused by trying to set 802.1X port control to auto or force-unauthorized (force_unauth) mode on a protocol tunneling-enabled port, which is not allowed.

Recommended Action    Disable protocol tunneling on the interface, and then enable 802.1X.

Error Message    DOT1X-5-ERR_PVLAN_EQ_VVLAN: Dot1x can not be enabled on a port with 
Access VLAN equal to Voice VLAN. 

Explanation    The switch cannot enable 802.1X on the interface that uses the same VLAN number for the access VLAN and the voice VLAN. This condition was caused by trying to set 802.1X port-control to auto or force-unauthorized (force_unauth) mode on a voice VLAN that uses the same VLAN as the access VLAN, which is not allowed.

Recommended Action    Change the voice VLAN or access VLAN on the interface, and retry the 802.1X operation.

Error Message    DOT1X-5-ERR_PVLAN_TRUNK:Dot1x can not be enabled on private VLAN trunk 
ports.

Explanation    802.1X cannot coexist with private VLAN trunking on the same port.

Recommended Action    This is an informational message only. No action is required.

Error Message    DOT1X-5-ERR_RADIUSVLAN_EQ_VVLAN: RADIUS attempted to assign a VLAN to 
Dot1x port [char] whose Voice VLAN is same as Access Vlan 

Explanation    The RADIUS server attempted to assign a VLAN to a supplicant on an interface whose voice VLAN settings are identical to the access VLAN settings.

Recommended Action    Update the RADIUS configuration so that the access VLAN settings are not identical to the voice VLAN settings for this interface.

Error Message    DOT1X-5-ERR_RSPAN_VLAN:Dot1x can not be enabled on ports configured in 
Remote SPAN vlan.

Explanation    802.1X cannot be enabled on the remote SPAN VLAN port. This condition is caused by trying to set 802.1X port control to auto or force-unauthorized (force_unauth) mode on a port that is in the remote SPAN VLAN, which is not allowed.

Recommended Action    Disable remove span on the VLAN, and then enable 802.1X.

Error Message    DOT1X-5-ERR_SPANDST: Dot1x can not be enabled on [char].  It is 
configured as a SPAN Dest port.

Explanation    The switch was not able to configure Dot1x on a given port because Dot1x and SPAN destination ports are mutually exclusive features.

Recommended Action    Disable the SPAN destination port configuration the reconfigure Dot1x on the port.

Error Message    DOT1X-5-ERR_TRUNK: Dot1x can not be enabled on Trunk port

Explanation    Because this port is a trunk port dot1x port-control cannot enter enable state with auto mode (or disable state with force-authorized mode).

Recommended Action    Disable trunking on the interface, and then enable 802.1X.

Error Message    DOT1X-5-ERR_TUNNEL:Dot1x can not be enabled on 802.1q tunnelling 
enabled ports

Explanation    802.1X cannot be enabled on the dot1q tunneling-enabled port. This condition is caused by trying to set 802.1X port control to auto or force-unauthorized (force_unauth) mode on a 802.1Q tunnel-enabled port, which is not allowed.

Recommended Action    Disable 802.1Q tunneling on the interface, and then enable 802.1X.

Error Message    DOT1X-5-ERR_VLAN_INTERNAL: The VLAN [dec] is being used internally and 
cannot be assigned for use on the Dot1x port [char] Vlan 

Explanation    The VLAN is used internally and cannot be assigned on this port.

Recommended Action    Update the configuration so that this VLAN is not used.

Error Message    DOT1X-5-ERR_VLAN_INVALID: The VLAN [dec] is invalid and cannot be 
assigned for use on   the Dot1x port [char] 

Explanation    The VLAN specified is out of range and cannot be assigned on this port.

Recommended Action    Update the configuration to use a valid VLAN.

Error Message    DOT1X-5-ERR_VLAN_NOT_ASSIGNABLE: Port [char] cannot be authenticated 
into VLAN [dec]

Explanation    Dot1x attempted to authenticate a port into a VLAN that is incompatible with the port type, such as a regular VLAN to a PVLAN host port, a private VLAN to an access port, or any VLAN to a routed or PVLAN promiscuous port. This can also occur when a PVLAN port has an incomplete local configuration on the switch.

Recommended Action    This is an informational message only. No action is required.

Error Message    DOT1X-5-ERR_VLAN_NOT_FOUND: RADIUS tried to assign non-existent VLAN 
name [char] to dot1x port

Explanation    The RADIUS server tried to assign a VLAN to a client on a port, but the VLAN name was not found in the VTP database.

Recommended Action    This is an informational message only. No action is required.

Error Message    DOT1X-5-ERR_VLAN_RESERVED: The VLAN [dec] is a reserved vlan and cannot 
be assigned for use on the Dot1x port [char] Vlan 

Explanation    The specified VLAN is a reserved VLAN and cannot be assigned for use on this port.

Recommended Action    Update the configuration so that this VLAN is not used.

Error Message    DOT1X-5-ERR_VLAN_RSPAN_CONFIGURED: VLAN [dec] is configured as a 
Remote SPAN VLAN

Explanation    Remote SPAN should not be enabled on a VLAN in which ports are configured with 802.1X enabled.

Recommended Action    Either disable remote SPAN configuration on the VLAN, or disable 802.1X on all the ports in this VLAN.

Error Message    DOT1X-5-INVALID_INPUT: Dot1x Interface parameter is Invalid on 
interface [char]

Explanation    The parameter that is specified for the 802.1X interface is not valid (it could be outside the range of valid values).

Recommended Action    Try again, using a valid value. See the CLI help to find the valid 802.1X parameters.

Error Message    DOT1X-5-INVALID_MAC: Invalid MAC address(drop, zero, broadcast or 
multicast mac address) <mac address> is trying to authenticate."

Explanation    Authentication is allowed for an invalid source MAC address because it is nonzero, it is not a broadcast, and it is not a multicast MAC address.

Recommended Action    Connect an 802.1X-supported host to the 802.1X-enabled interface.

Error Message    DOT1X-5-NOT_DOT1X_CAPABLE: Dot1x disabled on interface [char] because 
it is not an Ethernet interface

Explanation    The user attempted to configure 802.1X on a non-supported interface. 802.1X can be enabled on Ethernet module interfaces only.

Recommended Action    Enable 802.1X authentication on Ethernet interfaces only.

Error Message    DOT1X-5-SECURITY_VIOLATION: Security violation on interface [char] in 
single-host mode. Authorized MAC address was [mac-addr]

Explanation    That the port is configured in Single Host mode, so that any new host that is added to this interface results in a security violation and the port is shut down.

Recommended Action    Ensure that the port is configured to use only one host. Enter the shutdown command followed by the no shutdown command to restart the port.

DTP Messages

This section contains the Dynamic Trunking Protocol (DTP) messages.

DTP-4

Error Message    DTP-4-MEM_UNAVAIL:Memory not available to perform the trunk 
negotiation action

Explanation    The system is unable to negotiate trunks because of a lack of memory.

Recommended Action    Reduce other system activity to ease memory demands. If necessary, upgrade to a larger memory configuration.

Error Message    DTP-4-TMRERR:An internal timer error occurred when trunking on 
interface [char]

Explanation    Occasionally a timer used by the trunking protocol expires unexpectedly. This problem is corrected internally.

Recommended Action    This problem has no long-term ramifications. However, if further trunking problems persist, you should reload the device.

Error Message    DTP-4-UNKN_ERR:An unknown operational error occurred

Explanation    The system is unable to negotiate trunks because an internal operation generated an error that the protocol (DTP, in this case) did not expect to handle.

Recommended Action    Reload the device.

DTP-5

Error Message    DTP-5-ILGLCFG: Illegal config(on,isl--on,dot1q) on <mod/port>

Explanation    The two ports on the link are set to the ON mode, but one is set to 802.1Q encapsulation, while the other is set to ISL encapsulation. When both ports on a link are set to the ON mode, their encapsulation types must match.

Recommended Action    Configure both ports on the link to have the same encapsulation type.

Error Message    DTP-5-NONTRUNKPORTON:Port [dec]/[chars] has become non-trunk

Explanation    The interface [dec] / [chars] is nontrunked. [dec] / [chars] is the module number/interface range.

Recommended Action    This is an informational message only. No action is required.

Error Message    DTP-5-TRUNKPORTCHG:Port [dec]/[chars] has changed from [chars] trunk 
to [chars] trunk

Explanation    The encapsulation type of the trunk changed. [dec] is the module number, the first [chars] is the interface number, the second [chars] is the original encapsulation type, and the third [chars] is the new encapsulation type.

Recommended Action    This is an informational message only. No action is required.

Error Message    DTP-5-TRUNKPORTON:Port [dec]/[chars] has become trunk

Explanation    Interface [dec] / [chars] is trunked. [dec] / [chars] is the module number/interface range.

Recommended Action    This is an informational message only. No action is required.

Error Message    DTP-5-DOMAINMISMATCH: Unable to perform trunk negotiation on port 
[char] because of VTP domain  mismatch.

Explanation    The two ports involved in trunk negotiation belong to different VTP domains. Trunking is possible only when the ports involved belong to the same VTP domain.

Recommended Action    Reconfigure the switch to ensure that the two ports that are involved in trunk negotiation belong to the same VTP domain.

EBM Messages

This section contains the Ethernet bridge management (EBM) messages.

EBM-3

Error Message    C4K_EBM-3-CANTALLOCATEEBMPORT:No EbmPort memory to allocate EbmPort 
for PimPort [char]

Explanation    There is insufficient memory for information that is associated with the specified port.

Recommended Action    Install additional memory.

Error Message    C4K_EBM-3-CANTALLOCATEIENODE:No interposition table memory to add 
entry for addr %ea

Explanation    There is insufficient memory for this internal data structure.

Recommended Action    Install additional memory.

Error Message    C4K_EBM-3-CANTALLOCATEHOSTCHECKPOINTMESSAGE: Cannot allocate memory 
for host checkpoint message.  Layer2 host redundancy on standby will be out-of-sync 
with active.

Explanation    There is insufficient memory to allocate space for this internal data structure.

Recommended Action    You may need to install additional memory in both supervisor engines.

Error Message    C4K_EBM-3-CANTALLOCATEIGMPGROUPENTRY:No igmp group memory to add new 
group entry for addr [mac-addr]

Explanation    This error occurs if you have created a large number of IGMP groups and there is insufficient memory to support additional Internet Group Management Protocol (IGMP) group entries.

Recommended Action    Either install additional memory, or reduce the number of IGMP groups.

Error Message    C4K_EBM-3-CANTALLOCATEPORTHOSTENTRY:No port host table memory to add 
entry for addr [mac-addr] / [mac-addr]

Explanation    There is insufficient memory for this internal data structure.

Recommended Action    Install additional memory.

Error Message    C4K_EBM-3-CANTALLOCATEVLANGROUPENTRY:No vlan group table memory to add 
entry for addr %ea

Explanation    There is insufficient memory to support additional Layer 2 group entries corresponding to IP multicast groups.

Recommended Action    Install additional memory. If memory is unavailable, turn off Cisco Group Management Protocol (CGMP)/Internet Group Management Protocol (IGMP).

Error Message    C4K_EBM-3-CANTALLOCATEVLANHOSTENTRY:No vlan host table memory to add 
entry for addr %ea

Explanation    There is insufficient memory to support additional host addresses.

Recommended Action    Install additional memory.

EBM-4

Error Message    C4K_EBM-4-HOSTFLAPPING:Host [mac-addr] in vlan [dec] is flapping 
between port [char] and port [char]

Explanation    The specified host is detected as a source address on multiple ports. Typically, a host is supposed to be learned on only one port. A spanning tree loop is the most common cause of this condition. All traffic from the specified host is temporarily dropped. After 15 seconds, forwarding is reenabled. If the problem persists, the traffic from the problem host continues to be dropped indefinitely.

Recommended Action    Make sure that spanning tree is enabled to prevent spanning tree loops. If you have spanning tree disabled, make sure that you have no spanning tree loops in your network.

Error Message    C4K_EBM-4-MAXHOSTCHKPTMESSAGEQSIZEEXCEEDED: Backlog of checkpoint 
message waiting to be synced to standby has exceeded pre-defined limits.  The host 
table may become out-of-sync with active.

Explanation    The active supervisor engine is overloaded and unable to synchronize host messages to the standby supervisor engine or the standby supervisor engine is not in the proper state.

Recommended Action    Examine syslog messages from the active supervisor engine and standby supervisor engine to determine if any errors have been reported.

Error Message    C4K_EBM-4-ZEROETHERADDR:Filtering Ethernet MAC address of value zero 
from agent host table interface (port: [char])

Explanation    The switch received a packet with the MAC address 00:00:00:00:00:00. This MAC address is not valid and was probably generated by some non-IEEE 802.1D-compliant hardware or software in the network.

The host sort algorithm does not sort hosts with MAC addresses that have all zeros (00:00:00:00:00:00), because a MAC address that has all zeros can not be listed in the learned host table. A request to show learned hosts, either by the show cam dynamic command or by an SNMP request, does not list a MAC address that has all zeros.

Recommended Action    Track the source of the invalid MAC address because it might cause other problems.

EC Messages

This section contains the EtherChannel (EC) messages.

EC-4

Error Message    EC-4-NOMEM:Not enough memory available for [char]

Explanation    The Port Aggregation Protocol or EtherChannel cannot obtain the memory it needs.

Recommended Action    This is an informational message only. No action is required.

EC-5

Error Message    EC-5-BUNDLE:Interface [char] joined port-channel [char]

Explanation    The interface has joined the bundle.

Recommended Action    This is an informational message only. No action is required.

Error Message    EC-5-CANNOT_ALLOCATE_AGGREGATOR: Aggregator limit reached

Explanation    A new aggregator cannot be allocated in the group.

Recommended Action    Change the port attributes of the ports in the group so that they match and join the same aggregator.

Error Message    EC-5-CANNOT_BUNDLE1:Port-channel [char] is admin-down

Explanation    The administrative state of the aggregation port channel is down. The port remains in a standalone state until the state of the aggregation port is up.

Recommended Action    Ensure that all of the ports in the bundle have the same configuration.

Error Message    EC-5-CANNOT_BUNDLE2:[char] is not compatible with [char] and will be 
suspended ([char])

Explanation    The port has different port attributes from those of the port channel (or the ports within the port channel).

Recommended Action    Adjust the port attributes to match those of the port channel.

Error Message    EC-5-CANNOT_BUNDLE_LACP: [char] is not compatible with aggregators in 
channel [dec] and cannot attach to them ([char])

Explanation    This port has different port attributes than other ports within the port channel.

Recommended Action    Match the port attributes to that of the port channel.

Error Message    EC-5-CANNOT_BUNDLE_QOS: Removed [char] from port channel  because a 
QoS policy cannot be supported across multiple DFC cards.

Explanation    The port that is specified in the error message cannot join a port channel because the QoS policy that is attached to the port channel cannot support multiple DFC cards.

Recommended Action    Place the port in another port channel, or remove the QoS policy from the port channel.

Error Message    EC-5-COMPATIBLE: [char] is compatible with port-channel members

Explanation    The specified interface is not operational because its attributes are different from the attributes of the port channel or the attributes of the interfaces within the port channel. The switch detects that the attributes of the specified port now match the port-channel attributes.

Recommended Action    This is an informational message only. No action is required.

Error Message    EC-5-DONTBNDL: [char] suspended: incompatible partner port with [char]

Explanation    The configuration of the partner port is different from the configuration of the other ports in the bundle. A port can join the bundle only when the global configuration of the port and the configuration of the partner port are the same as the other ports in the bundle.

Recommended Action    Ensure that the configuration of the partner ports is the same for all ports in the bundle.

Error Message    EC-5-ERRPROT: Channel protocol mismatch for interface [char] in group 
[dec]: the interface can not be added to the channel group

Explanation    The interface cannot be added to the channel group with the specified mode.

Recommended Action    Change the channel group or the mode for the interface.

Error Message    EC-5-ERRPROT2: Command rejected: the interface [char] is already part 
of a channel with a different type of protocol enabled

Explanation    The interface cannot be selected for the specified protocol because it is already part of a channel with a different type of protocol enabled.

Recommended Action    Remove the interface from the channel group.

Error Message    EC-5-ERRPROT3: Command rejected: the interface [char] is already part 
of a channel

Explanation    The interface cannot be unselected for the specified protocol because it is already part of a channel.

Recommended Action    Remove the interface from the channel group.

Error Message    EC-5-L3DONTBNDL1:[char] suspended: PAgP not enabled on the remote 
port.

Explanation    PAgP is enabled on the Layer 3 interface, but the partner port does not have PAgP enabled. In this mode, the port is put in a suspended state.

Recommended Action    Enable PAgP on the remote side.

Error Message    EC-5-L3DONTBNDL2: [char] suspended: LACP currently not enabled on the 
remote port. 

Explanation    LACP is enabled on a Layer 3 interface, but the partner port does not have LACP enabled. In this mode, the port is put in a suspended state.

Recommended Action    Enable LACP on the remote side.

Error Message    EC-5-NOLACP: Invalid EC mode

Explanation    LACP is not included in the image. You cannot set EC mode to active or passive.

Recommended Action    Upgrade to an image with LACP, or set the mode to On.

Error Message    EC-5-NOPAGP:Invalid EC mode

Explanation    PAgP is not included in the image, so the EtherChannel mode cannot be set to desirable/auto.

Recommended Action    Obtain an image that includes PAgP, or set the mode to ON.

Error Message    EC-5-PORTDOWN: Shutting down [char] as its port-channel is admin-down 

Explanation    The administrative state of the aggregate port is down, which forces the administrative state of the port to also be down. The administrative state of the port is controlled by the administrative state of its aggregate port.

Recommended Action    Enter the no shutdown command on the aggregate port to activate the aggregation port.

Error Message    EC-5-STAYDOWN: [char] will remain down as its port-channel  [char] is 
admin-down

Explanation    An interface with EtherChannel configuration cannot be administratively up if its port channel is administratively down. Although this interface has an EtherChannel configuration, it has no information about the port channel. The no shutdown command is not supported.

Recommended Action    Wait for the module to come online.

Error Message    EC-5-UNBUNDLE:Interface [char] left the port-channel [char]

Explanation    The interface fell off the bundle.

Recommended Action    This is an informational message only. No action is required.

Error Message    EC-5-UNSUITABLE:[char] will not join any port-channel

Explanation    The configurations for PortFast, VMPS, and Dest-SPAN are incompatible with EtherChannel.

Recommended Action    Unconfigure the three features so that the port can form a bundle.

FLASH Messages

This section contains the Flash memory (C4K_FLASH) messages.

Error Message    C4K_FLASH-4-COMPACTFLASHNOTFOUND: Cannot find compact flash

Explanation    You may see this message if the compact flash is not inserted properly or if it is removed while the switch is trying to access the flash.

Recommended Action    Reinsert the compact flash and retry the operation.

Error Message    C4K_FLASH-4-COMPACTFLASHNOTREADY: Compact flash is not ready

Explanation    You may see this message if the compact flash is not inserted properly or if it is removed while the switch is trying to access the flash.

Recommended Action    Reinsert the compact flash and retry the operation.

GBICMAN Messages

This section contains the Gigabit Interface Converter (GBIC) Manager (GBICMAN) messages.

GBICMAN-3

Error Message    C4K_GBICMAN-3-BADGBIC:Port [char]: Gbic's seeprom is bad, try 
reinserting: vendor: [char], p/n: [char], s/n: [char]

Explanation    The Gigabit Interface Converter (GBIC) serial EEPROM data is corrupted.

Recommended Action    Remove and reinsert the GBIC.

Error Message    C4K_GBICMAN-3-GBICSEEPROMREADFAILED:Failed to read gbic serial eeprom 
on port [char], try reinserting

Explanation    The switch cannot identify the newly inserted GBIC or SFP.

Recommended Action    Remove and reinsert the GBIC or SFP.

Error Message    C4K_GBICMAN-3-S2WERROR: S2w bus error while looking for changed gbics 
on port [char]: [char]

Explanation    There was an internal communication error when the software read the GBIC/SFP control data.

Recommended Action    Contact your technical support representative.

HW Messages

This section contains the hardware (HW) message.

Error Message    C4K_HW-3-S2WERROR:[char] [char] [dec] Error: [object-info] Device 
Addr: [dec] Mem Addr: [object-info] Value: [dec]

Explanation    An unexpected error occurred when the switch accessed the hardware device specified in the message.

Recommended Action    Contact your technical support representative.

Error Message    C4K_HW-3-X2IDENTIFICATIONFAILURE:Error while trying to identify serdes 
type for  [char] ( [dec]  ) X2 module

Explanation    There was an error when trying to identify the X2 module type.

Recommended Action    Contact your technical support representative. You will probably need to replace the supervisor engine.

Error Message    C4K_HW-3-X2OUIREGREADFAILURE:Error while reading Supervisor X2 OUI 
register Device Addr: [dec]

Explanation    There was an unexpected error when accessing a hardware device with the given device address.

Recommended Action    Contact your technical support representative. You will probably need to replace the supervisor engine.

Error Message    C4K_HW-3-X2LOOPBACKFAILURE: Failed to put [char] Xaui([dec]) [char] 
loopback

Explanation    Software was unable to put the X2 in or out of loopback because it was unable to determine the X2 type.

Recommended Action    This is an informational message only. No action is required.

HWACLMAN Messages

This section contains the hardware ACL Manager (HWACLMAN) messages.

Error Message    C4K_HWACLMAN-4-ACLHWPROGERR:[input/output]  [char] - hardware TCAM 
limit,  [char]

Explanation    Some ACL-based features cannot be fully programmed into the hardware. Packets that use these features complete processing in the software. If the feature is a policy map, then QoS is completely disabled (on the specific interface).

This message lists the impacted feature; further messages list the specific failure that occurred.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_HWACLMAN-4-ACLHWPROGERRREASON:[input/output]  [object-info] 
[char] -  [char]

Explanation    This message provides a specific failure that prevented ACL-based features from being fully programmed into the hardware.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_HWACLMAN-4-CAMAUDIT: ACl/QOS CAM Health Check: [input/output] 
[char] Index:  [dec] [char] ( Cumulative Error Count: [dec] )

Explanation    The background system health monitor detected a potential problem.

Recommended Action    If this is a software error, the system has already corrected itself automatically and no action is required. If this is a hardware error, power cycle the switch.

Error Message    C4K_HWACLMAN-4-CAMBLOCKMASKALLOCFAILED: CAM state memory allocation 
failure in region [dec]

Explanation    The software could not allocate memory to maintain a software copy of the hardware classification TCAM masks that are used for ACL and QoS functionality.

Recommended Action    This condition should never occur. If you see this message, copy it exactly and contact your technical support representative.

Error Message    C4K_HWACLMAN-4-CLASSIFCAMPARITYERROR: Parity error detected in  
[input/output]  Classification CAM   [char] Cell  [object-info] and corrected

Explanation    The system detected and fixed a parity error in the hardware. If you see this error repeatedly, there is a strong likelihood of a hardware fault and the supervisor engine will need to be replaced.

Recommended Action    The software fixes the parity error by rewriting the CAM entries to the hardware. If the problem persists, contact your technical support representative.

Error Message    C4K_HWACLMAN-4-CLASSIFCAMREPLYPARITYERROR: Parity error detected in 
lookup response from  [input/output]  Classification CAM, Response Contents:  
[char]

Explanation    The system detected a transient error in the classification TCAM operation. If you see this message repeatedly, there is a strong likelihood of a fault in the switching engine ASICs and the supervisor engine will need to be replaced. Software will attempt to fix the parity error by rewriting the TCAM entries to the hardware.

Recommended Action    If the problem persists, contact your technical support representative.

Error Message    C4K_HWACLMAN-4-CLASSIFCAMREQPARITYERROR: Parity error detected in 
lookup request to  [input/output]  Classification CAM,   Data  [char] Address  
[char]

Explanation    The system detected a transient error in the Classification TCAM operation. If you see this error repeatedly, there is a strong likelihood of a fault in the switching engine ASICs and the supervisor engine will need to be replaced.

Recommended Action    If the problem persists, contact your technical support representative.

Error Message    C4K_HWACLMAN-4-QOSFEATUREOUTOFSWRESOURCES: Out of memory.   [char] is 
inactive  on port  [char]

Explanation    The software could not allocate memory to write the QoS related configuration to the QoS TCAM hardware. The given QoS policy configuration will not work on the given port until this is corrected.

Recommended Action    This condition might occur under extreme ACL and/or QoS configurations. Some workarounds to attempt are:

–Try reducing the unwanted QoS and ACL configurations from ports and VLANs.

–Try disabling and re-enabling QoS via the qos global configuration command.

If the problem persists, contact your technical support representative.

Error Message    C4K_HWACLMAN-4-WARNINGSTRING:[char]

Explanation    A nonspecific warning message was displayed.

Recommended Action    See the message string [char] for more information.

HWL2MAN Messages

This section contains the Layer 2 Hardware Manager (HWL2MAN) message.

Error Message    C4K_HWL2MAN-3-STMPARITYERROR: Parity error in Spanning Tree Memory.

Explanation    There is a parity error in the spanning tree memory, which can indicate a transient hardware problem or a more permanent problem.

Recommended Action    If you see this message too often, reboot the switch.

HWNETFLOWMAN Messages

This section contains the NetFlow Manager (HWNETFLOWMAN) messages.

HWNETFLOWMAN-3

Error Message    C4K_HWNETFLOWMAN-3-NETFLOWSTOPPED:Too many netflow parity errors 
encountered. It is very likely that this is bad Netflow hardware. Stopping all 
netflow related activities.

Explanation    The supervisor engine received too many parity errors from the NetFlow Services Card. The supervisor engine stops all NetFlow-related activities after issuing this message.

Recommended Action    Contact your technical support representative.

HWNETFLOWMAN-4

Error Message    C4K_HWNETFLOWMAN-4-HARDWAREUNRESPONSIVE: Netflow Hardware too slow in 
responding to software requests

Explanation    Software tried to access NetFlow hardware but there was no response. Typically this would indicate that the NetFlow related hardware may have gone bad.

Recommended Action    Contact your technical support representative.

Error Message    C4K_HWNETFLOWMAN-4-ERRORADDRS:Netflow Fatal Error Info: Interrupt 
Status ( [dec] ),  FDT1 Err Addr ( [dec] ),  FDT2 Err Addr ( [dec] ),  FLD Err 
Addr ( [dec] )

Explanation    A fatal NetFlow error occurred. The message contains critical information that can help you determine if the NetFlow hardware is functioning properly or is bad.

Recommended Action    Contact your technical support representative.

Error Message    C4K_HWNETFLOWMAN-4-FATALERRORINTERRUPTSEEN: Netflow Fatal Error 
interrupt seen

Explanation    The NetFlow Services Card sent a fatal interrupt call to the supervisor engine, which can crash the service card, the supervisor engine, and the entire switch. This condition is extremely rare.

Recommended Action    Contact your technical support representative.

Error Message    C4K_HWNETFLOWMAN-4-FLOWSLOSTERR: Netflow stats lost due to full hw 
flow table.  [char] [dec] packets.

Explanation    If the cache is full, then some flow statistics are lost. This message informs users about the total collected flow statistics. If the counter that tracks the lost statistics overflowed, an accurate count of total lost flows is not available.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_HWNETFLOWMAN-4-NOFREEFLOWPOLICERS:[dec] flow based policers are in 
use. All available flow  policers are in use. Can't allocate more number of flow 
policers

Explanation    The maximum number of flow policers that can be allocated by the system is 512. This message is displayed when the user tries to exceed that limit.

Recommended Action    Free existing flow policers before trying to define new ones.

Error Message    C4K_HWNETFLOWMAN-4-SWAGEDENTRYHWINVALIDATIONFAILED: Invalidation 
failed for Hw flow (index:  [object-info] ) associated with sw active-aged flow

Explanation    Software tried to access NetFlow hardware, but there was no response. Typically this would indicate that the NetFlow related hardware may have gone bad.

Recommended Action    Contact your technical support representative.

Error Message    C4K_HWNETFLOWMAN-4-NONFATALPARITYERRORINTERRUPTSEEN: Netflow Non 
Fatal Parity Error interrupt seen ( [dec] times)

Explanation    The supervisor engine received a nonfatal parity error from the NetFlow Services Card. The system should be able to recover from this condition. If this condition reoccurs often, the NetFlow Services Card is probably bad.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_HWNETFLOWMAN-4-SEDISABLEDAFTERDELAY: Se is Disabled After a Small 
Delay

Explanation    Software tried to access NetFlow hardware but there was no response. Typically this would indicate that the NetFlow related hardware may have gone bad. Access to the hardware was disabled.

Recommended Action    This is an informational message only. No action is required.

HWPORTMAN Messages

This section contains the hardware port management (HWPORTMAN) messages.

HWPORTMAN-4

Error Message    C4K_HWPORTMAN-4-BLOCKEDTXQUEUE:Blocked transmit queue HwTxQId[dec] on 
[char], count=[dec]

Explanation    A transmit queue on a port is blocked for reasons other than "paused." Bad hardware could cause this problem.

Recommended Action    Contact your technical support representative.

Error Message    C4K_HWPORTMAN-4-CHECKFORDUPLEXMISMATCHANDPAUSE: [char] Tx-Queue could 
be blocked due to duplex mismatch or receiving excessive pause frames

Explanation    Please use the show interface <name> count all command to verify the excessive collisions and pause frame counters. Duplex mismatch problems can be fixed by configuring both ends of a link in auto-negotiate mode. It can also be fixed by turning off auto-negotiation on both ends of the link and ensuring that the duplex configuration on both ends is the same. Excessive pause frames are not expected under normal conditions. If they occur, investigate on the other end of the link to address the problem. After fixing the problem, the port's TxQueue status can be checked by using the show platform hardware interface <name> tx command. The results will indicate whether one or more TxQueue's on this port are still stuck or working properly.

Recommended Action    If this message is seen when the duplex settings are correct, contact your technical support representative.

Error Message    C4K_HWPORTMAN-4-GIGAPORTRESETBYRXCONFIGWORD:[char] has been reset by 
the received autonegotiation word.

Explanation    The port stayed connected during switchover, but the device on the other end of the link lost synchronization and restarted autonegotiation.

Recommended Action    This is an informational message only. No action is required.

HWPORTMAN-7

Error Message    C4K_HWPORTMAN-7-FLOWCONTROLPACKET:Received invalid flow control 
packet from [char] da [mac-addr] sa [mac-addr] ethertype [hex] opcode [hex]

Explanation    The supervisor engine forwarded a malformed flow control packet to the software because one or both of the EtherType and flow control/operation code is incorrect. For flow control packets, the expected EtherType is 0x8808, and the expected operation code is 1 (xoff).

Recommended Action    If the devices that are connected to the switch can generate flow control and are configured for flow control, verify that the devices can generate well-formed flow control packets with valid EtherType and operation code fields.

IDBMAN Messages

This section contains the interface descriptor block (IDB) management (IDBMAN) messages.

IDBMAN-3

Error Message    IDBMAN-3-AGGPORTMISMATCH:[char]:[char]([dec] / [dec]) does match 
internal slot/port state [char]([dec] / [dec])

Explanation    Due to an internal error the software is using an invalid aggregate port.

Recommended Action    This is an informational message only. No action is required.

Error Message    IDBMAN-3-DELETEDAGGPORT:[char]([dec] / [dec]) Group [dec] has been 
deleted

Explanation    Software is reusing a deleted interface for a new aggregate port.

Recommended Action    This is an informational message only. No action is required.

Error Message    IDBMAN-3-INVALIDAGGPORTBANDWIDTH:[char]([dec] / [dec]) has an invalid 
bandwidth value of [dec]

Explanation    Software is using an invalid bandwidth for an aggregate port.

Recommended Action    This is an informational message only. No action is required.

Error Message    IDBMAN-3-INVALIDPORT:[char]:trying to use invalid port number [dec] 
(Max [dec])

Explanation    Software is using an invalid port number.

Recommended Action    This is an informational message only. No action is required.

Error Message    IDBMAN-3-INVALIDVLAN:[char]:trying to use invalid Vlan [dec]

Explanation    Software is using an invalid VLAN.

Recommended Action    This is an informational message only. No action is required.

Error Message    IDBMAN-3-NOTANAGGPORT:[char]([dec] / [dec]) is not an aggregate port

Explanation    Software is using an interface that is not an aggregate port for aggregate port operations.

Recommended Action    This is an informational message only. No action is required.

Error Message    IDBMAN-3-PORTNOTINAGGPORT:[char]([dec] / [dec]) is not present in 
Aggport [char]([dec] / [dec])

Explanation    Software recognizes that the invalid port belongs to an aggregate port.

Recommended Action    This is an informational message only. No action is required.

Error Message    IDBMAN-3-VLANINUSE:[char]:Vlan [dec] is in use by [char]

Explanation    Each Layer 3 interface has a VLAN that is associated with it. This message appears when some other Layer 3 interface is using the VLAN associated with the interface.

Recommended Action    This is an informational message only. No action is required.

Error Message    IDBMAN-3-VLANNOTSET:[char]:Vlan [dec] not set since it already has 
Vlan [dec] 

Explanation    Due to a software error, an interface's VLAN was set to a nonrequested value.

Recommended Action    This is an informational message only. No action is required.

IDBMAN-4

Error Message    IDBMAN-4-ACTIVEPORTSINAGGPORT:[char]([dec] / [dec]) has [dec] active 
ports

Explanation    Software has mistakenly removed an aggregate port with active ports.

Recommended Action    This is an informational message only. No action is required.

IDBMAN-6

Error Message    IDBMAN-6-VLANMAPPED:Vlan [dec] is mapped to [char]

Explanation    The given VLAN was mapped to the specified interface.

Recommended Action    This is an informational message only. No action is required.

ILCPROTOCOLERROR Messages

This section contains the ILC Protocol (ILCPROTOCOLERROR)message.

Error Message    C4K_ILC-3-PROTOCOLERROR: Service Module failed S2W protocol, error 
[dec], state [dec]

Explanation    The Serial 2-Wire (S2W) communication with an intelligent line card deviated from the defined protocol.

Recommended Action    This is an informational message only. No action is required.

IOSACLMAN Messages

This section contains the Catalyst 4500 series Cisco IOS ACL management (IOSACLMAN) messages.

Error Message    C4K_IOSACLMAN-4-ACLTYPEMISMATCH: Acl RkiosSharedIos[char] was earlier 
attached as [char] Acl. Please unconfigure all its uses before using it as a [char] 
Acl

Explanation    This message displays if you attach a named ACL as one type, delete the ACL, and configure an ACL of a different type with the same name. For example, you configure a named IP ACL using the name DefaultAcl, attach it to a router port, and then delete the ACL DefaultAcl by entering no ip access-list extended DefaultAcl. You could configure a MAC ACL using the same name. This message is displayed when you try to configure any ACEs in the MAC ACL.

Recommended Action    Remove all configurations where the ACL is used as an IP ACL before configuring a MAC ACL with the same name.

Error Message    C4K_IOSACLMAN-4-MOLACLALLOCFAILURE: Mol Acl Allocation for  [char] is 
failed

Explanation    A new MOL ACL was created but there was insufficient memory for a MOL ACL. The ACL was not applied.

Recommended Action    Remove all configurations where the ACL is used as an IP ACL before configuring a MAC ACL with the same name.

Error Message    C4K_IOSACLMAN-4-MOLACLFEATUREALLOCFAILURE: Mol AclFeature Allocation 
for Mol Acl:  [dec]  is failed

Explanation    A new MOL ACL was created but there was insufficient memory for a MOL ACL. The ACL was not applied.

Recommended Action    Remove all configurations where the MOL ACL is used as an IP ACL before configuring a MOL ACL with the same name.

Error Message    C4K_IOSACLMAN-4-VLANMAPOUTOFMEMORY: Could not add an entry to Vlan Map 
[char]. Out of memory

Explanation    The system has insufficient memory to allocate a new entry for this VLAN map.

Recommended Action    Remove all configurations where the ACL is used as an IP ACL before configuring a MAC ACL with the same name.

IOSDIAGMAN Messages

This section contains the Catalyst 4500 series Cisco IOS Diagnostic Manager (IOSDIAGMAN) messages.

Error Message    C4K_IOSDIAGMAN-4-CANNOTRUNTESTNOTPORTFAILEDBOOTUP: Cannot run the 
diag test as port failed bootup tests

Explanation    The online diagnostic test requested cannot be run on this port because the port failed bootup tests.

Recommended Action    Investigate why the bootup tests have failed on the port. The module or the port may be damaged.

Error Message    C4K_IOSDIAGMAN-4-TESTNOTSUPPORTEDONMODULE: [char] is not supported on 
this module

Explanation    The online diagnostic test requested is not supported on this module.

Recommended Action    If the diagnostic test is required, consider upgrading to hardware that supports the test.

IOSDHCPSNOOPMAN Messages

This section contains the Catalyst 4500 series Cisco IOS DHCP Snooping Manager (IOSDHCPSNOOPMAN) messages.

Error Message    C4K_IOSDHCPSNOOPMAN-4-CANNOTADDNEWIPLIST: Cannot add new IP list for 
dhcp security on [char] and vlan [dec]

Explanation    The switch attempted to add a new IP address to the list of permitted IP addresses but failed. The new addresses are not permitted.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSDHCPSNOOPMAN-4-CANNOTENABLESECURITY: Cannot enable dhcp 
security on [char] and vlan [dec]

Explanation    The switch failed to enable IP source guard on the interface and indicated VLAN. This error probably occurred because there might be too many interface-VLAN pairs that have the feature enabled.

Recommended Action    This is an informational message only. No action is required.

IOSIGMPSNOOPMAN Messages

This section contains the Catalyst 4500 series Cisco IOS IGMP Snooping Manager (IOSIGMPSNOOPMAN) message.

Error Message    C4K_IOSIGMPSNOOPMAN-3-NOSPACELEFT:No igmp group memory to add new 
group entry

Explanation    There is insufficient memory to support additional IGMP group entries, which are added automatically when you run CGMP or IGMP.

Recommended Action    Install additional memory, or reduce the number of IGMP groups.

IOSINTF Messages

This section contains the Catalyst 4500 series Cisco IOS interface operation (IOSINTF) messages.

IOSINTF-4

Error Message    C4K_IOSINTF-4-DYNAMICPOLICYMEMOVERFLOW: Dynamic policy memory 
exhausted - [char] policy for host %i on port [char]  not fully applied.

Explanation    The memory allocated for dynamic host policies (dynamic ACLs and URL redirection) has been completely used. The policy for the host and interface specified is not fully applied by the platform. Traffic from the host on that interface may hit the default PACL instead.

Recommended Action    Reduce either the number of hosts on the system with dynamic host policies or the size of the dynamic policies being applied.

Error Message    C4K_IOSINTF-4-INTVLANALLOCFAIL:Failed to allocate internal VLAN for 
interface [char]. The interface will remain down.

Explanation    When a routed port or port channel interface is enabled, it must map to an internal VLAN in order to operate. If there are no internal VLANs available when an interface is enabled, the interface remains down and this message is logged.

Recommended Action    An internal VLAN can be freed by disabling some other routed port or port channel interface or by deleting a user-configured VLAN in the 1006 to 4094 range. Once a VLAN is made available, the interface will come up if it is disabled and reenabled.

Error Message    C4K_IOSINTF-4-REFLEXIVEACLNOTSUPPORTED: Reflexive Acls are not 
supported. Ignoring the [char] entry.

Explanation    The reflexive ACLs are not supported. ACEs with the evaluate and reflect keywords are ignored.

Recommended Action    Do not configure ACEs with the evaluate or reflect keywords.

IOSINTF-5

Error Message    C4K_IOSINTF-5-GBICINSERTED: Slot= [dec] Port= [dec]:  GBIC has been 
inserted

Explanation    An approved-vendor GBIC or SFP was inserted.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSINTF-5-GBICREMOVED: Slot= [dec] Port= [dec]: GBIC has been 
removed

Explanation    An approved-vendor GBIC or SFP was removed.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSINTF-5-NOPRIMARYVLANASSOCIATION:Packet received on interface 
[char] in vlan [dec]  without primary vlan association. [mac-addr] will not be 
secured.

Explanation    The switch received a packet on a secondary VLAN which does not have a primary VLAN association. The switch will not secure a MAC address in this situation.

Recommended Action    Associate this secondary VLAN with a valid primary VLAN.

Error Message    C4K_IOSINTF-5-NOTXVLAN:Router Port [char] has no internal vlan 
assigned to transmit packet

Explanation    The specified Layer 3 interface does not have an assigned internal VLAN because duplicate IP network assignments exist on different Layer 3 interfaces.

Recommended Action    Remove the duplicate IP network that is configured on the interface. Assign the correct IP network, and enter the no shutdown command on this interface.

Error Message    C4K_IOSINTF-5-NOTXVLAN:Router Port [char] has no internal vlan 
assigned to transmit packet

Explanation    Occasionally during hot-swapping operations a previously queued packet is transmitted after the module in that slot was removed. Because the module no longer exists, the packets are dropped.

Recommended Action    If the problem persists even without any hot-swapping operations, contact your technical support representative.

Error Message    C4K_IOSINTF-5-OUTPACLDISABLEDUETORACL: Output PACL [char] is disabled 
on port [char]

Explanation    If the port is configured for an SVI that has output RACL, then the output PACL on the port is disabled. Output RACL and output PACL are mutually exclusive, it is not possible to configure both simultaneously.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSINTF-5-OUTPACLDISABLEDUETOVACL: Output PACL [char] is disabled 
on port [char]

Explanation    If the port is configured for a VLAN that has output RACL, then the output PACL on the port is disabled. Output RACL and output PACL are mutually exclusive, it is not possible to configure both simultaneously.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSINTF-5-STALEPHYPORT: Dropping packets to be transmitted out on 
port [char]  ( Linecard in Slot [dec] may have been removed )

Explanation    During hot-swapping operations a previously queued packet may be transmitted after a switching module is removed. This indicates such packets are being dropped.

Recommended Action    If this message appears without any hot swapping, please contact your technical support representative.

Error Message    C4K_IOSINTF-5-RJ45ACTIVE: Slot= [dec] Port= [dec]:  RJ45 connector has 
become active

Explanation    A dual media port changed from using the SFP connector to using the RJ-45 connector.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSINTF-5-RJ45INACTIVE: Slot= [dec] Port= [dec]: RJ45 connector 
has become inactive

Explanation    A dual media port changed from using the RJ-45 connector to the SFP connector.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSINTF-5-TXL3PKTONPHYPORT:Transmitting L3 packet on a physical 
port [char] that is part of [char] ([dec] packets). Make sure the physical port 
in the L3 port channel does not have an ip addresses configured on it. 

Explanation    Layer 3 protocols operate at the logical, not the physical, port level. Layer 3 protocol packets were sent on a physical port that is part of a bundle. This condition occurs if there is a misconfiguration; a physical port that is part of a Layer 3 port channel might have been assigned an IP address.

Recommended Action    Verify that the physical interface in the Layer 3 port channel does not have an IP address that is assigned to it.

Error Message    C4K_IOSINTF-5-TXPKTDROPONETHERCHANNEL:Dropping transmit packet out of 
interface [char]

Explanation    A packet that should be transmitted out of a port channel was dropped during transitions in the port channel membership. This condition occurs when a packet is transmitted out of the aggregate port by higher layer protocols, but the software cannot find the specific state information or when physical ports transition into or out of the port channel membership.

Recommended Action    If the problem persists, contact your technical support representative.

IOSIPROUTEMAN Messages

This section contains the Catalyst 4500 series Cisco IOS IP Route Manager (IOSIPROUTEMAN) messages.

IOSIPROUTEMAN-3

Error Message    C4K_IOSIPROUTEMAN-3-ADJMANNOMOREADJS:AdjMan:
hardware adjacency resources exhausted, performance may be degraded.

Explanation    The hardware adjacency resources have been exhausted. The supervisor engine will forward packets to this adjacency in the software. This action will likely represent a significant performance degradation.

Recommended Action    Reduce the number of adjacencies that are loaded into the routing table, and then clear the IP routing table.

Error Message    C4K_IOSIPROUTEMAN-3-FIBCANTALLOCATEFIBADJ:IOS IP Route Manager:No 
memory available to allocate FIB Adjacency for [object-info] 

Explanation    The switch does not have sufficient memory to allocate space for this adjacency; the supervisor engine will forward it in the software instead.

Recommended Action    Reconfigure the network so that there are fewer hosts that are directly adjacent to the Catalyst 4500 series switch, and then clear and reload all of the routes (or reboot) so that the adjacent hosts that were being sent to the software get reloaded.

Error Message    C4K_IOSIPROUTEMAN-3-FIBCANTALLOCATEFIBENTRY:IOS IP Route Manager:No 
memory available to allocate FIB Entry for [ip-addr] 

Explanation    The switch has insufficient memory to allocate space for the route that is associated with this network.

Recommended Action    Contact your technical support representative because memory leaks might exist.

Error Message    C4K_IOSIPROUTEMAN-3-PBRDOESNOTSUPPORTQOS:Route-map ' [char]  ' on 
interface ' [char]  ' specifies Quality of Service rewriting which is not supported 
via Policy-Based Routing on this platform. Please use the Quality of Service 
feature instead. This action on the specified route map will be ignored.

Explanation    The switch does not support QoS services that are implemented using PBR route maps. The PBR route map that is specified will be loaded, but references to QoS services will be ignored.

Recommended Action    Use the QoS policy maps and class maps to configure this feature.

Error Message    C4K_IOSIPROUTEMAN-3-VRFMANNOMOREVRFS: VrfMan: VPN routing forwarding 
resources exhausted.

Explanation    The VPN routing forwarding resources have been exhausted.

Recommended Action    Reduce the total number of VPNs in the switch.

Error Message    C4K_IOSIPROUTEMAN-3-WCCPINVALIDMASKASSIGNMENTTABLE: Invalid mask 
assignment table received for WCCP service group  [char]

Explanation    The number of distinct masks in the new mask assignment table is more the maximum number supported for a service group on the switch. The new table is discarded. Since a valid mask assignment table is not available anymore, the service group cannot redirect traffic. All the traffic that was expected to be redirected is now routed normally.

Recommended Action    Make sure that the cache engine is correctly configured to send a valid mask assignment table to the switch.

IOSIPROUTEMAN-4

Error Message    C4K_IOSIPROUTEMAN-4-WCCPUNCHANGEDMASKASSIGNMENTTABLE: Mask assignment 
table update received but the table has not changed for WCCP service group [char]

Explanation    The service group has received a new mask assignment table identical to the current table. This could be due to a misconfiguration on the content engine side. The table change indication will be ignored and the service group continues to use the current table for redirection.

Recommended Action    Please check the configuration on the content engine side to make sure that this unnecessary update does not get sent. If the configuration looks correct and the content engine is not sending the same table repeatedly but you still see this message, please contact your technical support representative.

IOSL2MAN Messages

This section contains the Catalyst 4500 series Cisco IOS Layer 2 Manager (IOSL2MAN) message.

Error Message    C4K_IOSL2MAN-3-VLANCREATIONERROR:Unable to create new vlan [dec]

Explanation    The switch does not have sufficient memory to allocate new VLANs, so the new VLAN allocation failed.

Recommended Action    Contact your technical support representative because memory leaks might exist.

IOSMODPORTMAN Messages

This section contains the Catalyst 4500 series Cisco IOS module Port Manager (IOSMODPORTMAN) messages.

IOSMODPORTMAN-3

Error Message    C4K_IOSMODPORTMAN-3-SSOMODULEREADYTIMEOUT: Internal event: timed out 
after [dec] iterations waiting for the slot [dec] to become ready.

Explanation    There is an internal logic error. The state of this switching module's ports will not be synchronized to the standby supervisor engine.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-3-SPANCONFIGOUTOFMEMORY: RkiosSpanMan: Out of 
memory. Unable to process information for RkiosSpanMan: ID. [dec] 

Explanation    The system ran out of memory.

Recommended Action    Contact your technical support representative.

Error Message    C4K_IOSMODPORTMAN-3-UNKNOWNPOWERSUPPLY: Unsupported Power Supply has 
been inserted in slot [dec]

Explanation    An unsupported or unknown power supply was inserted.

Recommended Action    Replace the power supply with a supported power supply.

IOSMODPORTMAN-4

Error Message    C4K_IOSMODPORTMAN-4-CRITICALTEMP: Chassis temperature is at or over 
critical threshold - current temp: [dec]C, critical threshold: [dec]C

Explanation    The chassis temperature is above a critical threshold. If some action is not taken immediately to cool the chassis, the system shuts down to prevent damage to the hardware.

Recommended Action    Remove one or more modules to reduce the temperature of the chassis, and check if the fan tray is functional.

Error Message    C4K_IOSMODPORTMAN-4-CLOCKMODULEFAULTY: Clock module switched to  [dec]  
reason [char] for more info use the cmd:'show environment status clock'

Explanation    The clock module is faulty and may have to be replaced.

Recommended Action    Contact your technical support representative to confirm that replacing the clock module is necessary.

Error Message    C4K_IOSMODPORTMAN-4-INLINEPOWEROVERMAX:Inline power exceeds max 
threshold:Module status changed to 'Pwr Max'

Explanation    The measured PoE usage is higher than the module's physical limit. This situation can be caused by misconfiguration or by one or more unauthorized appliances drawing more PoE than allocated. In installations with a 1400 W DC power supply, this warning can be a false positive. Refer to bug id CSCef49715.

Recommended Action    Make sure that the right amount of PoE is allocated to each device. If the PoE allocation is correct, remove powered devices one at a time and see if the power usage decreases as expected. (You can use the show power detail command to see the PoE allocated to the module and the PoE used.) If the power usage decreases sharply when a device is disconnected, chances are that this device is using more PoE than allocated. Avoiding using this device should solve your problem. If after disconnecting all the devices on the module, the PoE usage is still high, and the system does not use 1400 W DC power, contact you technical support representative.

Error Message    C4K_IOSMODPORTMAN-4-SSOMODULEOLDVERSION: Received stale 
acknowledgement for the linecard in slot [dec]: expected [dec], received [dec].

Explanation    This is most probably the result of a linecard being rapidly removed and reinserted.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-4-FANTRAYBAD:Fan tray has failed

Explanation    The fan tray failed.

Recommended Action    Replace the fan tray as soon as possible.

Error Message    C4K_IOSMODPORTMAN-4-FANTRAYPARTIALFAILURE: A fan or thermistor/s in 
system fan tray have failed

Explanation    This is a warning message indicating that one or more fans or thermal sensors in the system fan tray have failed.

Recommended Action    Schedule a time to replace the fan tray soon. System performance should not be immediately affected.

Error Message    C4K_IOSMODPORTMAN-4-FANTRAYREMOVED:Fan tray has been removed

Explanation    The fan tray was removed.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-4-FANTRAYGOOD:Fan tray is okay

Explanation    The fan tray passed all tests and is operating normally.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-4-INLINEPOWERSUPPLYBAD: Inline power from power 
supply [dec] has failed or been turned off 

Explanation    A PoE source from a power supply failed or was turned off. The hardware cannot make a distinction between the two cases.

Recommended Action    Verify that the incoming power is good, and if it is replace the power supply as soon as possible.

Error Message    C4K_IOSMODPORTMAN-4-NFLABSENT: Netflow Services Card absent or idprom 
invalid on [char] supervisor.

Explanation    The recommended configuration for using the NetFlow Services Card is to have it installed on both the standby and active supervisor engines. Otherwise, during switchover, the system might lose its NetFlow capabilities.

Recommended Action    Verify that the NetFlow Services Card is installed on both supervisor engines.

Error Message    C4K_IOSMODPORTMAN-4-NFLIDPROMINVALID: Netflow Services Card has 
invalid idprom on [char] supervisor

Explanation    The IDPROM on the NetFlow Services Card on the supervisor engine indicated in the message is invalid.

Recommended Action    Contact your technical support representative.

Error Message    C4K_IOSMODPORTMAN-4-NFLMISMATCH: Netflow Services Cards have 
mismatched [char]. ([dec] on [char] and [dec] on [char]).

Explanation    The IDPROM attributes of the NetFlow Services Cards installed on the active and the standby supervisor engines do not match.

Recommended Action    Verify that the NetFlow Services Card is correctly installed on both supervisor engines.

Error Message    C4K_IOSMODPORTMAN-4-PEMBAD: Power Entry Module has failed

Explanation    The external power supply source providing PoE power is bad.

Recommended Action    Check the external power supply and replace it, if necessary. This message is most likely to occur in a system using a 1400 W DC power supply and an external power shelf providing DC current to the DC power supply.

Error Message    C4K_IOSMODPORTMAN-4-POWERSUPPLYBAD:Power Supply [dec] has failed or 
been turned off

Explanation    A power supply failed or was turned off. The hardware cannot make a distinction between the two cases.

Recommended Action    Replace the power supply as soon as possible.

Error Message    C4K_IOSMODPORTMAN-4-POWERSUPPLYFANBAD:Fan of power supply [dec] has 
failed

Explanation    A power supply fan failed.

Recommended Action    Replace the power supply as soon as possible.

Error Message    C4K_IOSMODPORTMAN-4-POWERSUPPLYREMOVED:Power supply [dec] has been 
removed

Explanation    The power supply was removed.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-4-POWERSUPPLYOUTPUTDECREASED: Power supply [dec] 
output has decreased

Explanation    The power supply output decreased. This could be due to switching it off, power failure, or some failure in the power supply.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-4-TEMPHIGH: Chassis temperature is at or over 
threshold - CurrentTemp: [dec]C, Threshold: [dec]C

Explanation    The chassis temperature is above the threshold. If the temperature goes above a critical threshold, another message is logged and the system shuts down to prevent damage to the hardware.

Recommended Action    Inspect the chassis and environment to determine the cause of the rise in temperature. Cool the system.

Error Message    C4K_IOSMODPORTMAN-4-TEMPUNDERCRITICAL: Chassis temperature is now 
under critical threshold but still very high - current temp:  [object-info] C, 
critical threshold: [object-info] C

Explanation    The chassis temperature is now below the critical threshold. The chassis is still operating above the normal temperature.

Recommended Action    Inspect the chassis to determine the cause of the temperature problem. Cool the system.

IOSMODPORTMAN-6

Error Message    C4K_IOSMODPORTMAN-6-CLOCKSWITCHOVER: Chassis Clock Module switched to 
Clock: [dec]

Explanation    This indicates that the clock module switched over to another clock.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-INLINEPOWERSUPPLYGOOD: Inline power from power 
supply [dec] is Ok

Explanation    The PoE power supply just inserted in [dec] is functioning normally.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-POWERSUPPLYOUTPUTINCREASED: Power supply [dec] 
output has increased

Explanation    The indicated power supply output increased.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-FANTRAYINSERTED:Fan tray has been inserted

Explanation    The fan tray was inserted.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-FANTRAYINSERTEDDETAILED: Fan tray ([char] S/N: 
[char] Hw: [dec].[dec]) has been inserted

Explanation    The fan tray was inserted.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-INLINEPOWEROK:Inline power within limits:Module 
status changed to 'Ok'

Explanation    The measured PoE is now below the configured value and the physical limit for the module.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-MODULEINSERTED: Module [dec] is inserted

Explanation    A module was inserted into slot [dec].

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-MODULEOFFLINE: Module [dec] is offline

Explanation    The specified module is offline.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-MODULEONLINE:Module [dec] ([char] S/N:[char] 
Hw:[dec].[dec]) is online

Explanation    The specified module is online.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-MODULEREMOVED: Module [dec] is removed

Explanation    A module was removed from slot [dec].

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-PACKETMEMORYERRORPOWERCYCLE:Supervisor power 
cycled due to packet memory errors

Explanation    This supervisor engine was power cycled to get rid of SRAM errors detected in the packet memory. It is expected that the transient SRAM errors in packet memory are cleared by a power cycle of a supervisor engine.

Recommended Action    Contact your technical support representative.

Error Message    C4K_IOSMODPORTMAN-6-PACKETMEMORYERRORSOFTRESET:Supervisor soft reset 
due to packet memory errors

Explanation    This supervisor engine was reset because it encountered SRAM errors in the packet memory. It was soft reset either because it does not have self power cycle capability or the switch is operating in SSO mode.

Recommended Action    Contact your technical support representative.

Error Message    C4K_IOSMODPORTMAN-6-PEMGOOD: Power Entry Module has been restored to 
working condition

Explanation    The external power supply source providing PoE is working correctly.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-POWERSUPPLYFANGOOD:Fan of power supply [dec] is 
okay

Explanation    A failed power supply was fixed.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-POWERSUPPLYGOOD:Power supply [dec] is okay

Explanation    A failed power supply was fixed.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-POWERSUPPLYINSERTED:Power supply [dec] has been 
inserted

Explanation    The specified power supply was inserted.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-POWERSUPPLYINSERTEDDETAILED: Power supply [dec] 
([char] S/N: [char] Hw: [dec].[dec]) has been inserted

Explanation    A power supply was inserted.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSMODPORTMAN-6-TEMPOK: Chassis temperature is now ok - 
CurrentTemp: [dec]C, Threshold: [dec]C

Explanation    The chassis temperature is now normal.

Recommended Action    This is an informational message only. No action is required.

C4K_IOSREDUNDANCYMAN Messages

This section contains the Catalyst 4500 series Cisco IOS module Redundancy Manager (IOSREDUNDANCYMAN) messages.

Error Message    C4K_IOSREDUNDANCYMAN-3-BUFFERALLOCATIONFAILED:RkiosCheckpointMan:Buf
fer allocation error (client:[char], error:[dec]) 

Explanation    There was an internal error when allocating resources for the checkpoint facility.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSREDUNDANCYMAN-3-CHECKPOINTMESSAGESENDFAILURE:RkiosCheckpointM
an:Message send failure (client:[char])

Explanation    There was an internal error when allocating resources for the checkpoint facility.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSREDUNDANCYMAN-3-NEWCHECKPOINTCLIENTFAILED:RkiosCheckpointMan:
Error adding new client (client:[char], error:[dec])

Explanation    There was an internal error when allocating resources for the checkpoint facility.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IOSREDUNDANCYMAN-3-NEWCLIENTREGISTRATIONFAILED:RkiosRedundancyMa
n:Error adding new client (client:[char], error:[dec])

Explanation    There was an internal error when allocating resources for the redundancy facility.

Recommended Action    This is an informational message only. No action is required.

IOSSYS Message

This section contains the Catalyst 4500 series IOS system (IOSSYS) messages.

IOSSYS-3

Error Message    C4K_IOSSYS-3-BLANKSTARTUPCONFIG: Blank or invalid startup-config 

Explanation    An empty or invalid startup-config file was found in the NVRAM. The switch is booting up with default settings.

Recommended Action    Configure the switch and save the configuration to NVRAM as the startup file for the next reboot. If the problem persists, contact your technical support representative.

Error Message    C4K_IOSSYS-3-SAVEPOSTRESULTFAILED: Failed to save POST results to 
[char]. [char]. 

Explanation    The system cannot save the POST results to bootflash because the bootflash memory might be full.

Recommended Action    Check if the bootflash memory is full. If the bootflash memory is full, delete the old POST results by entering the delete \force post* and the squeeze bootflash: commands.

IOSSYS-4

Error Message    C4K_IOSSYS-4-BLANKPRIVATECONFIG: Blank or invalid private-config

Explanation    An invalid private-config is found in the NVRAM, or the private-config was missing.

Recommended Action    If this message comes up after a software upgrade, try saving the configuration again and reboot the switch. If the message goes away in the next boot, then it can be ignored. If this message displays each time that the switch is rebooted, contact your technical support representative.

IOSSYS-7

Error Message    C4K_IOSSYS-7-INVALIDVALUE: [char] Type [dec] not handled returning a 
default of 0

Explanation    This message is used by developers only and should not occur during customer operation.

Recommended Action    Contact your technical support representative.

Error Message    C4K_IOSSYS-7-SETENVERR: Failed to set environment variable: [char].

Explanation    The system cannot write the specified environment variable because the bootflash memory or NVRAM has insufficient memory.

Recommended Action    Clear the unnecessary environment variables by entering the clear platform environment variable unsupported command, and then reboot your switch.

IOSSYSMAN Messages

This section contains the Catalyst 4500 series Cisco IOS System Manager (IOSSYSMAN) messages.

IOSSYSMAN-0

Error Message    C4K_IOSSYSMAN-0-FATALERRORCRASH:Forced crash due to: [char]

Explanation    The system is unusable due to software or hardware failures.

Recommended Action    Analyze the memory dump, if any, and determine the cause of the failure, or contact your technical support representative.

IOSSYSMAN-3

Error Message    C4K_IOSSYSMAN-3-ENVVARNAMETOOLONG:Name of environment variable

Explanation    The environment variable name is too long.

Recommended Action    Enter the unset command to shorten the name.

Error Message    C4K_IOSSYSMAN-3-OUTOFPACKETHEADERS:Cannot allocate buffer for a packet 
header

Explanation    The system cannot allocate a buffer for the packet header.

Recommended Action    Contact your technical support representative, and provide the configuration information for the switch.

IOSSYSMAN-4

Error Message    C4K_IOSSYSMAN-4-ENVVARTOOLONG: Value of env. variable [char] is too 
long

Explanation    The software writes certain configuration values to the NVRAM. The variable name is too long (greater than 4096 bytes) for the available storage space.

Recommended Action    Boot the system into ROMMON mode. At the ROMMON prompt, enter the unset command to change the environment variable name to a shorter name.

Error Message    C4K_IOSSYSMAN-4-NOSPACEFORENVVAR: Env. variable [char] cannot be set: 
no space

Explanation    The software writes certain configuration values to the NVRAM. The switch has insufficient memory to write an environment variable.

Recommended Action    Boot the system into ROMMON mode. At the ROMMON prompt, enter the unset command to remove the unused environment variables to reclaim the space.

IPROUTEMAN Messages

This section contains the Catalyst 4500 series Cisco IOS IP Routing Manager (IPROUTEMAN) messages.

IPROUTEMAN-3

Error Message    C4K_IPROUTEMAN-3-CANTALLOCATEIPETHERADDRENTRY:IP Route Manager:No 
memory to add Router Port MAC Address, numInUse: [dec] 

Explanation    Each router port in the system can listen to secondary MAC addresses as the "router's MAC address," which is a process that is useful for protocols like Hot Standby Routing Protocol (HSRP). The system does not have sufficient memory to hold a secondary MAC address.

Recommended Action    Boot the switch into ROMMON mode. At the ROMMON prompt, enter the unset command to remove the unused environment variables to reclaim the space.

Error Message    C4K_IPROUTEMAN-3-FIBADJMANDUPLICATEADJ:FIB Entry:Tried to create a 
duplicate adj for key [object-info]

Explanation    A request was made to add a duplicate adjacency to the Forwarding Information Base (FIB) adjacency database.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-FIBADJMANINUSEDELETION:FIB Adjacency 
Manager:Attempted to delete FIB Adjacency Id [dec] which is in use

Explanation    A request was made to delete an adjacency from the Forwarding Information Base (FIB) database while that adjacency was still referenced by a routing table entry.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-FIBADJMANNONEXISTENTDELETION:FIB Adjacency 
Manager:Attempted to delete FIB Adjacency Id [dec] which does not exist

Explanation    A request was made to delete an adjacency from a platform Forwarding Information Base (FIB) that does not exist.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-FIBDUPLICATEENTRY:FIB:Attempt to create a duplicate 
FIB Entry for [ip-addr]

Explanation    A request to add a duplicate routing table entry to the Forwarding Information Base (FIB) database was detected.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-FIBENTRYNOSUCHADJTODELETE:FIB Entry:Couldn't delete 
adj [ip-addr] from FIB Entry [ip-addr], no such adj.

Explanation    A request was made to delete an adjacency from a routing table entry in the platform Forwarding Information Base (FIB), and the adjacency was not found.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-FIBENTRYTOOMANYADJ:FIBEntry: FIB Entry: Too many 
adjacencies on FIB Entry for [ip-addr], tried to add adj  [ip-addr]

Explanation    A request was made to add another adjacency to a routing table entry in the platform Forwarding Information Base (FIB) when that entry was already at the maximum allowed value.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-FIBNONEXISTENTDELETION:FIB:Attempted to delete FIB 
Entry Id [dec] which does not exist

Explanation    A request was made to delete a nonexistent routing table entry from the platform Forwarding Information Base (FIB).

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-NOMOREK2FIBADJS:K2FibUnicast:no more K2FibAdjs 
available, using punt adj instead for [ip-addr] route.

Explanation    The hardware resources for adjacencies have been exhausted; switching will take place in the software instead. The switch performance might be degraded.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-VRFMANDUPLICATEVRF: Tried to create a duplicate VRF 
for key  [object-info]

Explanation    A request was made to add a duplicate VRF.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_IPROUTEMAN-3-VRFMANNONEXISTENTDELETION: Attempted to delete VRF 
with key  [object-info] which does not exist

Explanation    A request was made to delete a VRF that does not exist.

Recommended Action    This is an informational message only. No action is required.

IPROUTEMAN-4

Error Message    C4K_IPROUTEMAN-4-CANTALLOCATEFIBENTRY: FIB: No memory available to 
allocate FIB Entry 

Explanation    The switch has insufficient memory to allocate space for the route that is associated with this network.

Recommended Action    Install additional memory.

Error Message    C4K_IPROUTEMAN-4-VRFMANCANTALLOCATEVRF: No memory available to 
allocate VRF for key  [object-info]

Explanation    The switch has insufficient memory to allocate space for VRF.

Recommended Action    Install additional memory.

L2MAN

This section contains the L2MAN messages.

Error Message    C4K_L2MAN-6-INVALIDSOURCEADDRESSPACKET:Packet received with invalid 
source MAC address ( [mac-addr]  ) on port [char]   in vlan  [dec]

Explanation    A packet was received with an all zero or a multicast source address. The packet is treated as invalid and no learning is done. Excessive flow of such packets can waste CPU cycles. This message is rate-limited and is displayed only for the first such packet received on any interface or VLAN. Subsequent messages will display cumulative count of all such packets received in given interval on all interfaces.

Recommended Action    Check the switch configuration file to find the source of these packets on the specified port and take corrective action to fix them at the source end. You can also enable port security on that interface to shutdown the port if the incoming rate of packets with invalid source mac address is too high by issuing the switchport port-security limit rate invalid-source-mac <rate> command.

Error Message    C4K_L2MAN-7-ROUTERMACADDRESSRXASSOURCE: Packet received with my own 
MAC address ( [mac-addr]  ) as source on port [char]   in vlan  [dec]

Explanation    A packet was received with the switch's MAC address as the source address. This MAC was not learned as a valid source address, which suggests that there is a configuration problem. This message is rate-limited and is displayed only for the first such packet received on any interface or VLAN. Subsequent messages will display a cumulative count of all such packets received in a given interval on all interfaces in any VLAN. This usually signifies a loop in your configuration. This problem can occur in three conditions; L1 loop, L2 loop, or a host with a bogus MAC address is connected to the switch.

Recommended Action    For L1 loop, verify that the physical connection on the port appears in the syslog message to see if there is a loopback connection. Also use the show cdp neighbor command to see if the switch is seeing itself.

For L2 loop, first use the show spanning-tree interface <intf> command to make sure spanning tree is running for that port. Then use the show spanning-tree vlan <vlan-id> command to make sure the VLAN appears in the syslog on all related switches and confirm that the reported information (including Bridge ID, blocking ports, port priority, etc) is correct across all the switches in the topology. If the STP protocol appears to be working, then capture traffic on the blocking ports to see if it sends traffic. If yes, please contact your technical support representative.

For the third case, determine whether the connected host has its MAC address manually configured to the value of the switch which shows the syslog message.

L3HWFORWARDING Messages

This section contains the Layer 3 hardware forwarding (L3HWFORWARDING) messages.

L3HWFORWADING-2

Error Message    C4K_L3HWFORWARDING-2-FWDCAMFULL:L3 routing table is full. Switching to 
software forwarding.

Explanation    The hardware routing table is full; forwarding takes place in the software instead. The switch performance might be degraded.

Recommended Action    Reduce the size of the routing table. Enter the ip cef command to return to hardware forwarding.

L3HWFORWARDING-3

Error Message    C4K_L3HWFORWARDING-3-FTECONSISTENCYCHECKFAILED: FwdTableEntry 
Consistency Check Failed: index  [dec] 

Explanation    There was a consistency check failure. If this error occurs frequently, it could indicate faulty hardware.

Recommended Action    If the problem persists, contact your technical support representative.

Error Message    C4K_L3HWFORWARDING-3-FWDCAMCONSISTENCYCHECKFAILED: FwdCam Consistency 
Check Failed: index  [dec] 

Explanation    There is a FwdCam consistency check failure. If this error occurs frequently, it could indicate faulty hardware.

Recommended Action    If the problem persists, contact your technical support representative.

Error Message    C4K_L3HWFORWARDING-3-FWDMEMPARITYERROR: Parity error in Forwarding 
Memory

Explanation    There is a parity error in forwarding memory. This error message could indicate a transient hardware problem or a more permanent problem.

Recommended Action    If you see this message multiple times, reboot the switch.

Error Message    C4K_L3HWFORWARDING-3-MASKTABLECONSISTENCYCHECKFAILED: MaskTable 
Consistency Check Failed: block  [dec] 

Explanation    There was a mask table consistency check failure. If this error occurs frequently, it could indicate faulty hardware.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_L3HWFORWARDING-3-MASKTABLEREGIONCONSISTENCYCHECKFAILED: MaskTable 
Consistency Check Failed: region  [object-info] 

Explanation    There is a consistency check failure in the mask table. The error is located in the region that is specified by [object-info].

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_L3HWFORWARDING-3-NOMOREK2FIBADJS:No hardware adjacency resource 
available for route [ip-addr] 

Explanation    The hardware adjacency table has insufficient memory to allocate the adjacency set for this route. Forwarding will take place in the software instead.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_L3HWFORWARDING-3-PBRBLOCKFAILEDTOADDFLATACE:K2FibPbrBlock:failed 
to add FlatAce  [object-info] to block  [dec]

Explanation    The policy-routing data structures are corrupted. This memory corruption will probably crash the switch soon.

Recommended Action    Contact your technical support representative.

Error Message    C4K_L3HWFORWARDING-3-PBRBLOCKFAILEDTODELETEFLATACE:K2FibPbrBlock: 
failed to remove FlatAce  [object-info] from block  [dec]

Explanation    The policy-routing data structures are corrupted. This memory corruption will probably crash the switch soon.

Recommended Action    Contact your technical support representative.

Error Message    C4K_L3HWFORWARDING-3-PBRFLATTENINGFAILED: Software resource 
exhaustion trying to load route-map  for interface  [char]  ( [dec]  ), elapsed 
time is  [object-info] us 

Explanation    The switch has insufficient memory to process the access list for a route map.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_L3HWFORWARDING-3-PBRNOPBRCAMLEFT: K2FibPbr: attempted addition of  
[dec] blocks to PBR cam region failed, only managed to get  [dec] for FRM  [char] 

Explanation    There is insufficient memory to program a new route map.

Recommended Action    Remove unused portions of the configuration to free the needed memory.

Error Message    C4K_L3HWFORWARDING-3-PBRPUNTINGPORT: Policy routing exceeded maximum 
TCAM usage, all IP unicast  traffic on interface  [char]  will be switched in 
software.

Explanation    The hardware policy-based routing forwarding engine has insufficient resources to handle the route map for the specified interface. All unicast IP traffic for that interface will be switched in the software instead.

Recommended Action    This is an informational message only. No action is required.

L3HWFORWARDING-4

Error Message    C4K_L3HWFORWARDING-4-FLOWCACHEOUTOFSPACEFORFLOWCACHEENTRY: 
K2FibFlowCache: insufficient space to store flow of type  [object-info] with label  
[packet-info] 

Explanation    The software cannot load a flow cache entry into the hardware due to insufficient memory.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_L3HWFORWARDING-4-FWDCAMOUTOFSPACEFORVRFROUTINGTABLE: Insufficient 
TCAM resources to load VRF  [char]  routing table. Switching to software forwarding 
for this VRF.

Explanation    The software could not load the VRF routing table into the TCAM because there were not enough hardware resources available for the operation. Traffic on this VRF will now be routed in software at reduced forwarding performance.

Recommended Action    Reduce the Layer 3 forwarding hardware resource use, by reducing the number of routes loaded or by reducing the number of VLANs contained within the VRF. When the hardware requirements are reduced sufficiently, Cisco IOS software automatically reloads the VRF's routes into hardware. When this happens, the C4K_L3HWFORWARDING-6-SUCCEEDEDTOLOADVRFROUTINGTABLETOFWDCAM message appears.

Error Message    C4K_L3HWFORWARDING-4-FWDCAMOUTOFSPACEFORWCCPREDIRECTION: WCCP Service 
Group [char] failed to setup one or more routed ports/SVI for redirection due to 
lack of TCAM entries. 

Explanation    One or more VLANs corresponding to L3 routed ports or SVI could not be set up for redirection because there is insufficient room for more TCAM entries. Ingress IPv4 traffic on these VLANs will be routed normally. When the hardware requirements have been reduced sufficiently, the switch will automatically enable redirection for those VLANs.

Recommended Action    Reduce the layer 3 forwarding hardware resource utilization, either by reducing the number of routes loaded or by reducing the number of VLANs contained within this WCCP service group. If the redirection is not enabled even after freeing up memory from these actions, please contact Cisco technical assistance.

L3HWFORWARDING-6

Error Message    L3HWFORWARDING-6-NOLONGERPBRPUNTINGPORT: Sufficient Policy Routing 
TCAM space has been found to handle PBR for interface  [char]  in hardware, no 
longer punting to software.

Explanation    The hardware policy-based routing forwarding engine now has sufficient resources to handle the route map for the specified interface and can now do hardware forwarding of unicast IP traffic.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_L3HWFORWARDING-6-SUCCEEDEDTOLOADVRFROUTINGTABLETOFWDCAM: 
Successfully loaded VRF  [char]  routing table to TCAM.  Switching to hardware 
forwarding for this VRF.

Explanation    A VRF that was previously being routed by software is now fully reloaded and hardware forwarding has resumed. Refer to the C4K_L3HWFORWARDING-4-FWDCAMOUTOFSPACEFORVRFROUTINGTABLE message for more information.

Recommended Action    This is an informational message only. No action is required.

LINECARDMGMTPROTOCOL Messages

This section contains the module management protocol (LINECARDMGMTPROTOCOL) messages.

Error Message    C4K_LINECARDMGMTPROTOCOL-3-FAILEDTOSEND: EsmpDriver [char] - Failed to 
send ESMP requests due to [char].

Explanation    This message indicates a failure in ESMP request generation for the reason given. This is probably due to high CPU utilization caused by a number of factors, and under these circumstances switching module communication protocol packets can not be transmitted.

Recommended Action    If you see this message frequently, analyze the traffic going to the CPU and contact your technical support representative to debug the problem.

Error Message    C4K_LINECARDMGMTPROTOCOL-4-INITIALTIMEOUTWARNING:
[char] - management request timed out.

Explanation    There are communication problems with the module ASIC that fans out a single gigabit port to front-panel ports. A few messages are within tolerance levels.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_LINECARDMGMTPROTOCOL-4-ONGOINGTIMEOUTWARNING:
[char] - consecutive management requests timed out.

Explanation    There are persistent communication problems with the module ASIC that fans out a single gigabit port to front-panel ports.

Recommended Action    Reinsert the module.

LINECARDMGMTPROTOCOL Messages

This section contains the LAN Port IP (LPIP) dynamic host policies (LPIPMAN) messages.

Error Message    C4K_LPIPMAN-4-OUTOFMEMORY: Memory for constructing ACLs is not 
available.

Explanation    System memory is not available to set up LPIP dynamic host policies. LPIP host policies do not work if this log message appears.

Recommended Action    To correct this problem either free some memory on the switch or upgrade the switch with additional RAM.

PKTPROCESSING Messages

This section contains the packet processing (PKTPROCESSING) messages.

PKTPROCESSING-3

Error Message    C4K_PKTPROCESSING-3-INVALIDVLAN:Packet received on invalid Vlan from 
hardware. PortId [dec] [l2-header]   Vlan [dec] TagType [object-info]

Explanation    The hardware sent a packet to the CPU, but the receiving VLAN was incorrect. There is probably a hardware problem.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PKTPROCESSING-3-OUTOFPACKETINFOTODRIVER: \"Ran out of memory to 
send packet information to the driver that enqueues packets to hardware\"

Explanation    Transmit packets are probably stuck in a queue, and some of the packets have been sent to multiple destinations. This event wastes memory, so new packet information cannot be allocated.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PKTPROCESSING-3-OUTOFPACKETSTODRIVER: \"Ran out of memory to send 
packets to the driver that enqueues packets to hardware\"

Explanation    Transmit packets are probably stuck in a queue, so new packets cannot be queued.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_PKTPROCESSING-3-REPLICATEDINVALIDVLAN: Replicated packet received 
on Vlan 0, CRC32 is valid. PortId [dec] [l2-header] Vlan [dec] TagType 
[object-info] count [object-info] 

Explanation    A replicated packet was received on VLAN 0. The CRC32 packet is correct. If the count is high, there may be a hardware problem.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PKTPROCESSING-3-UNEXPECTEDOUTPUTACLHIT:Packet hit output ACL but 
sent to CPU as a result of hardware input Acl processing [l2-header] Port char] 
Vlan [dec]

Explanation    A n inconsistent hardware state might exist. A packet was sent to the CPU due to input ACL processing by the hardware. The packet unexpectedly encountered output ACL processing.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PKTPROCESSING-3-UNRECOGNIZEDEVENT:Packet received for an 
unimplemented event. CPU Subport [dec] TxQId [dec] PDD {[dec], [dec]}

Explanation    The hardware sent a packet to the CPU, but the software did not recognize the event that triggered the packet to be sent.

Recommended Action    This is an informational message only. No action is required.

PKTPROCESSING-4

Error Message    C4K_PKTPROCESSING-4-ERRORPACKET:[char]

Explanation    The software is unable to process a packet; the packets have been forwarded to the CPU instead and the packet will be dropped.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_PKTPROCESSING-4-UNKNOWNBRIDGEORROUTEREPLICATED: Unable to 
determine whether to route or bridge replicated software-processed packet with 
source  mac  [mac-addr]  , destination mac  [mac-addr]  , source IP  [ip-addr]  , 
destination IP  [ip-addr]

Explanation    When a replicated packet is sent to the software by an output ACL, the hardware does not indicate whether the packet needs to be bridged or routed.

When resources are exhausted or when the ACLs that are programmed in the hardware cannot handle processing directly (such as ACLs matching TCP flags), the supervisor engine sends the packets to the software for processing. If the software cannot determine whether to bridge or route, the packet might be dropped. This drop indicates that the packet was directed to a Hot Standby Routing Protocol (HSRP) router group MAC address.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_PKTPROCESSING-4-INVALIDACLACTION:Unable to determine the ACL 
action to take because we ran out of memory. Address: src  [mac-addr]  dst  
[mac-addr]

Explanation    There is insufficient memory to create a list of actions to perform on the packet. As a result, the packet was dropped.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_PKTPROCESSING-4-INVALIDACLACTIONFORSPANPORT: Unable to determine 
the ACL action to take because we ran out of memory. Address:  src  [mac-addr]  
dst  [mac-addr]

Explanation    There is insufficient memory to create a list of actions to perform on the packet. As a result, the packet was dropped.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_PKTPROCESSING-4-UNKNOWNBRIDGEORROUTE: Unable to determine whether 
to route or bridge software-processed packet with source  mac  [mac-addr]  , 
destination mac  [mac-addr]  , source IP  [ip-addr]  , destination IP  [ip-addr]

Explanation    When a replicated packet is sent to the software by an output ACL, the hardware does not indicate whether the packet needs to be bridged or routed.

When resources are exhausted or when the ACLs that are programmed in the hardware cannot handle processing directly (such as ACLs matching TCP flags), the supervisor engine sends the packets to the software for processing. If the software cannot determine whether to bridge or route, the packet might be dropped. This drop indicates that the packet was directed to a Hot Standby Routing Protocol (HSRP) router group MAC address.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_PKTPROCESSING-4-UNKNOWNSOURCELOCATIONFORBRIDGE:Unable to 
determine source host location of replicated software-processed packet with source 
address  [mac-addr]  and destination address  [mac-addr] 

Explanation    When a replicated packet is sent by an output ACL to the software for processing, the hardware does not indicate the ingress port or VLAN ID.

When resources are exhausted or when the ACLs that are programmed in the hardware cannot handle processing directly (such as ACLs matching TCP flags), the supervisor engine sends the packets to software for processing. Without the ingress port identifier, the supervisor engine might forward the packet back out the port on which it was received, possibly creating network loops or other problems. If the switch is unable to recognize the ingress port from other information, the packet is dropped.

Recommended Action    This is an informational message only. No action is required.

PKTPROCESSING-5

Error Message    C4K_PKTPROCESSING-5-NOTAPPLYINGACL:Not applying [input/output] Acl 
for packet [packet-info] 

Explanation    The software is unable to determine the correct ACL entry that is indicated by the hardware. The hardware-provided index of the ACL content-addressable memory (CAM) indicates that the software needs to take the actions for the entry at that index. If the packet was queued in the hardware before the software could process it, the index is out of date.

Recommended Action    This is an informational message only. No action is required.

PKTPROCESSING-7

Error Message    C4K_PKTPROCESSING-7-ADJLOOKUPFAILED:Draining the backed up packets in 
CPU queue when we cleaned up FIB adjacencies. Last drained packet's source address  
[ip-addr]  and destination address  [ip-addr]

Explanation    This event can occur when the software processes the routed packets and the router port is shut down. The software can automatically repair adjacencies, but there was at least one packet in the queue that was lost.

Recommended Action    This is an informational message only. No action is required.

Pluggable Messages

This section contains the SFP management (C4K_PLUGGABLEMAN) messages.

Error Message    C4K_PLUGGABLEMAN-3-BADX2: Port [char]: X2's seeprom is bad, try 
reinserting: vendor: [char], p/n: [char], s/n: [char]

Explanation    The X2 SEEPROM data may be corrupted.

Recommended Action    Reinsert the X2 module.

Error Message    C4K_PLUGGABLEMAN-3-ETHHOLEERROR: EthHolePluggableMan reviewing port 
[char], EthHoleError [char]

Explanation    The software is unable to read the SEEPROM on this X2.

Recommended Action    Contact your technical support representative. You will probably have to replace the X2 module.

Error Message    C4K_PLUGGABLEMAN-3-X2SEEPROMREADFAILED: Failed to read x2 serial 
eeprom on port [char], try reinserting

Explanation    The system could not identify the newly inserted X2.

Recommended Action    Re-insert the X2 module.

PM Messages

This section contains the Port Manager (PM) messages.

PM-2

Error Message    PM-2-LOW_SP_MEM: Switch process available memory is less than [dec] 
bytes

Explanation    The switch has insufficient memory for processing. Too many Layer 2 VLANs might have been configured in the system.

Recommended Action    Remove Layer 2 VLANs or other features from the system to reduce memory usage.

Error Message    PM-2-NOMEM:Not enough memory available for [char]

Explanation    The Port Manager subsystem cannot obtain sufficient memory for the specified PM operation. [char] is the PM operation ID.

Error Message    PM-2-VLAN_ADD:Failed to add VLAN [dec] - [char].

Explanation    The VLAN was not added to VTP, because of the reason stated in the text string.

Recommended Action    This is an informational message only. No action is required.

PM-3

Error Message    PM-3-ERR_INCOMP_PORT: [dec]/[dec] is set to inactive because 
[dec]/[dec] is a [char] port

Explanation    The private host port cannot be configured with the trunk, private, promiscuous, and SPAN destination port on the same coil.

Recommended Action    Try to configure the incompatible ports on different coils.

Error Message    PM-3-INTERNALERROR:Port Manager Internal Software Error 
([char]:[char]:[dec]:[char])

Explanation    The access VLAN on the VMPS server is set to the same VLAN as a voice VLAN on the port. The access VLAN assignment on the VMPS server should be different from the voice VLAN.

Recommended Action    Reset the VLAN assignments to remove the conflict.

PM-4

Error Message    PM-4-BAD_APP_ID:an invalid application id [dec] was detected

Explanation    The Port Manager detected a request with an invalid application ID, where [dec] is the application ID.

Recommended Action    Reset the VLAN assignments to remove the conflict.

Error Message    PM-4-BAD_APP_REQ:an invalid [char] request by the `[char]' application 
was detected

Explanation    The Port Manager detected an invalid request. The first [char] is the invalid request, and the second [char] is the application making the request.

Recommended Action    Reset the VLAN assignments to remove the conflict.

Error Message    PM-4-BAD_CARD_COOKIE:an invalid card cookie was detected

Explanation    The Port Manager detected an invalid request.

Recommended Action    Reset the VLAN assignments to remove the conflict.

Error Message    PM-4-BAD_CARD_SLOT:an invalid card slot [dec] was detected

Explanation    The Port Manager detected an invalid request on slot number [dec].

Recommended Action    Reset the VLAN assignments to remove the conflict.

Error Message    PM-4-BAD_COOKIE:[char] was detected

Explanation    The Port Manager detected an invalid request.

Recommended Action    Reset the VLAN assignments to remove the conflict.

Error Message    PM-4-BAD_HA_ENTRY_EVENT: Invalid Host access entry event ([dec]) is 
received

Explanation    The entry event is not an add, delete, or update event (the only supported types).

Recommended Action    Enter the show tech-support privileged EXEC command to gather data that might provide information about the error. If you cannot determine the cause of the error from the error message or from the show tech-support command display, copy the error message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    PM-4-BAD_PORT_COOKIE:an invalid port cookie was detected

Explanation    The Port Manager detected an invalid request.

Recommended Action    Enter the show tech-support privileged EXEC command to gather data that might provide information about the error. If you cannot determine the cause of the error from the error message or from the show tech-support command display, copy the error message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    PM-4-BAD_PORT_NUMBER:an invalid port number [dec] was detected

Explanation    The Port Manager detected an invalid request on interface number [dec].

Recommended Action    Enter the show tech-support privileged EXEC command to gather data that might provide information about the error. If you cannot determine the cause of the error from the error message or from the show tech-support command display, copy the error message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    PM-4-BAD_VLAN_COOKIE:an invalid vlan cookie was detected

Explanation    The Port Manager detected an invalid request.

Recommended Action    Try a different VLAN on the device.

Error Message    PM-4-BAD_VLAN_ID:an invalid vlan id [dec] was detected

Explanation    The Port Manager detected an invalid request. The invalid VLAN ID is [dec].

Recommended Action    Try a different VLAN on the device.

Error Message    PM-4-ERR_DISABLE:[char] error detected on [char]

Explanation    The Port Manager will put the interface in the errdisable state when it detects a misconfiguration or misbehavior. After the configured retry time (5 minutes by default), the system will attempt to recover the interface.

Recommended Action    This is an informational message only. No action is required.

Error Message    PM-4-ERR_RECOVER:Attempting to recover from [char] err-disable state 
on [char]

Explanation    The system is attempting to bring the interface back from the errdisable state.

Recommended Action    This is an informational message only. No action is required.

Error Message    PM-4-EXT_VLAN_INUSE: VLAN [dec] currently in use by [char]

Explanation    The Port Manager failed to allocate the VLAN for external use because the VLAN is currently occupied by another feature.

Recommended Action    Reconfigure the feature to use another internal VLAN, or request another available VLAN.

Error Message    PM-4-EXT_VLAN_NOTAVAIL: VLAN [dec] not available in Port Manager

Explanation    The Port Manager failed to allocate the requested VLAN. The VLAN might be used as an internal VLAN by other features.

Recommended Action    Reconfigure the feature to use another internal VLAN, or request another available VLAN.

Error Message    PM-4-INACTIVE: putting [char] in inactive state because [char]

Explanation    The Port Manager was blocked from creating a virtual port for the switch port and VLAN, causing the port to be inactive. The reason for this condition is specified in the error message.

Recommended Action    Try a different VLAN on the device.

Error Message    PM-4-INT_FAILUP: [char] failed to come up. No internal VLAN available

Explanation    The Port Manager failed to allocate the internal VLAN, and the interface cannot start.

Recommended Action    Remove extended-range VLANs to free resources.

Error Message    PM-4-INT_VLAN_NOTAVAIL: Failed to allocate internal VLAN in Port 
Manager

Explanation    The Port Manager failed to find any available internal VLAN.

Recommended Action    Delete some extended-range VLANs that are created by users, or remove some features that require internal VLAN allocation, such as a routed port.

Error Message    PM-4-INVALID_HOST_ACCESS_ENTRY: Invalid Host access entry type ([dec]) 
is received

Explanation    The host access entry should be either configured or dynamic.

Recommended Action    Reconfigure the host access entry using the correct type.

Error Message    PM-4-LIMITS:Virtual port count for [char] exceeded the recommended 
limit of [dec]

Explanation    There is a limit of 1200 virtual ports per module and a maximum of 4500 per switch. This limit was exceeded.

Recommended Action    Reduce the number of trunks and VLANs in the module (or switch) that is specified in the error message. Make sure that the overture port and VLAN port count is below the recommended limit.

Error Message    PM-4-NO_SUBBLOCK:No PM subblock found for [char]

Explanation    A Port Manager (PM) subblock was not found for this interface.

Recommended Action    Enter the show tech-support privileged EXEC command to gather data that might provide information about the error. If you cannot determine the cause of the error from the error message or from the show tech-support command display, copy the error message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    PM-4-PORT_BOUNCED: Port [char] was bounced by [char].

Explanation    The Port Manager needed to perform a reactivation of a port in the link-down state during a switchover. A port is only reactivated when the port data structures lack consistency between the active and standby supervisor engines. The reactivation event returned the active ports in the link-down state to the link-up state.

Recommended Action    This is an informational message only. No action is required.

Error Message    PM-4-PORT_CONSISTENT:Port [char] consistency has been restored

Explanation    The port manager on the standby supervisor engine discovered that the port state became consistent again.

Recommended Action    This is an informational message only. No action is required.

Error Message    PM-4-PORT_INCONSISTENT: Port [char] is inconsistent: IDB state  [char] 
(set %TE ago)

Explanation    The port manager on the standby supervisor engine discovered that the port state was inconsistent for more that one second. Inconsistent ports are reactivated on switchover (you will see the PORT_BOUNCED message).

Recommended Action    This is an informational message only. No action is required.

Error Message    PM-4-PVLAN_TYPE_CFG_ERR: Failed to set VLAN [dec] to a [char] VLAN

Explanation    The platform failed to set the private VLAN type.

Recommended Action    Enter the show tech-support privileged EXEC command to gather data that might provide information about the error. If you cannot determine the cause of the error from the error message or from the show tech-support command display, copy the error message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    PM-4-TOO_MANY_APP:application `[char]' exceeded registration limit

Explanation    The Port Manager detected an invalid request. [char] in the application.

Recommended Action    Reconfigure the host access entry using the correct type.

Error Message    PM-4-UNKNOWN_HOST_ACCESS: Invalid Host access value ([dec]) is 
received

Explanation    A n invalid host access value was sent to the host access table.

Recommended Action    Reconfigure the host access entry using the correct type.

Error Message    PM-4-VMPS_CFG: Dynamic access VLAN [dec] same as voice vlan on [char].

Explanation    The access VLAN on the VMPS server is set to the same VLAN as the voice VLAN on the port.

Recommended Action    Change the assignments so that the access VLAN assignment on the VMPS server is different from the voice VLAN.

PORTFANOUTASIC4X1000MAN Messages

This section contains the Port Fan-out ASIC 4x1000 Manager (PORTFANOUTASIC4X1000MAN) messages. This ASIC takes a gigabit port and fans it out to four 1000-Mb ports.

Error Message    C4K_PORTFANOUTASIC4X1000MAN-4-DIAGSFAILED:[char] failed diagnostics

Explanation    The module ASIC that is identified by [char] failed diagnostics.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PORTFANOUTASIC4X1000MAN-4-FAILEDTOSENDLOOPBACKTRIES:[char] port 
[dec] failed to send packet in [dec] tries

Explanation    The module ASIC [char] was unable to send a loopback packet on a module ASIC port for the [dec]th time. The switch has insufficient memory and will attempt to send a loopback packet only up to three times.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PORTFANOUTASIC4X1000MAN-4-UNEXPECTEDLOOPBACK:
[char] sent out a loopback packet on port [dec], but it came back on port [dec]

Explanation    The module ASIC diagnostics for [char] sent a loopback packet out port [dec], and it came back on another port [dec]. This condition is rare because the loopback is internal to the hardware.

Recommended Action    Contact your technical support representative.

PORTFANOUTASIC8X1000HW Messages

This section contains the Port Fan-out ASIC 8x1000 Hardware (PORTFANOUTASIC8X1000HW) message. This ASIC takes a gigabit port and fans it out to eight 1000-Mb ports.

PORTFANOUTASIC8X1000HW-3

Error Message    C4K_PORTFANOUTASIC8X1000HW-3-UNKNOWNDEVICEID: [char] - Linecard 
Management Protocol info register has unknown device id [hex] 

Explanation    Each module ASIC has an information register on it that contains the device ID field (DID) of the ASIC. When the module ASIC driver read this register, it discovered that the DID type was invalid.

The [char] field of the DID might contain <asic-code>(x) where x is the gigabit port of the switching engine to which the module ASIC is attached. The hex field of the DID contains the device ID. The expected value is 0x0450.

Recommended Action    Contact your technical support representative.

PORTFANOUTASIC8X1000HW-4

Error Message    C4K_PORTFANOUTASIC8X1000MAN-4-DIAGSFAILED: [char] failed diagnostics

Explanation    The module ASIC identified by [char] failed diagnostics.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PORTFANOUTASIC8X1000MAN-4-FAILEDTOSENDLOOPBACKTRIES: [char] port 
[dec] failed to send packet in [dec] tries

Explanation    The module ASIC [char] is unable to send a loopback packet on the module ASIC interface [dec] and this is the decth time that it has tried to send and failed. The switch attempts to send a loopback packet only up to three times. The switch is out of memory.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PORTFANOUTASIC8X1000MAN-4-UNEXPECTEDLOOPBACK: [char] sent out a 
loopback packet on port [dec], but it came back on port [dec]

Explanation    The module ASIC diagnostics for [char] sent a loopback packet out interface [dec] and it came back on another interface [dec]. This condition is unexpected because the loopback is internal to the hardware.

Recommended Action    Contact your technical support representative.

PORTFANOUTASIC8X1000HW-7

Error Message    C4K_PORTFANOUTASIC8X1000MAN-7-LOSTPACKET: [char] port [dec] lost one 
or more packets, [dec] transmitted [dec] received

Explanation    A loopback packet was lost during online diagnostics of the module ASIC [char].

Recommended Action    This is an informational message only. No action is required.

PORTFANOUTASIC8X100MAN Messages

This section contains the Port Fan-out ASIC 8x100 Manager (PORTFANOUTASIC8X100MAN) messages. This ASIC takes a gigabit port and fans it out to eight 100-Mb ports.

PORTFANOUTASIC8X100MAN-4

Error Message    C4K_PORTFANOUTASIC8X100MAN-4-DIAGSFAILED: [char] failed diagnostics

Explanation    The module ASIC that is identified by [char] failed diagnostics.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PORTFANOUTASIC8X100MAN-4-FAILEDTOSENDLOOPBACKTRIES:[char] port 
[dec] failed to send packet in [dec] tries

Explanation    The module ASIC [char] was unable to send a loopback packet on the module ASIC port [dec] for the decth time. The switch has insufficient memory; it will attempt to send a loopback packet up to three times.

Recommended Action    Contact your technical support representative.

Error Message    C4K_PORTFANOUTASIC8X100MAN-4-UNEXPECTEDLOOPBACK:
[char] sent out a loopback packet on port [dec], but it came back on port [dec]

Explanation    The module ASIC diagnostics for [char] sent the loopback packet out port [dec] and it came back on another interface [dec]. This condition is rare because the loopback is internal to the hardware.

Recommended Action    Contact your technical support representative.

PORTFANOUTASIC8X100MAN-7

Error Message    C4K_PORTFANOUTASIC8X100MAN-7-LOSTPACKET:[char] port [dec] lost a 
packet

Explanation    A loopback packet was lost during online diagnostics of this port.

Recommended Action    This is an informational message only. No action is required.

QOS Messages

This section contains the quality of service (QOS) message.

Error Message    C4K_QOS-4-OUTOFPOLICERRESOURCES:Out of memory to allocate a policer

Explanation    The software failed to allocate memory for a policer while processing the QoS configuration, possibly because the policer configuration exceeded its maximum supported limit.

Recommended Action    Remove policers from other unwanted policies, and retry the operation. Resend the command when other Telnet sessions are not sending debugging commands.

REDUNDANCY Messages

This section contains the supervisor engine redundancy (REDUNDANCY) messages.

REDUNDANCY-2

Error Message    C4K_REDUNDANCY-2-HANDSHAKE_TIMEOUT_ACTIVE: The handshake messaging 
between active and standby has not yet started.

Explanation    The initial handshake message exchange between active and standby supervisor engines has not yet started. Traffic on the active supervisor engine is not affected, but supervisor engine redundancy will not work.

Recommended Action    Please schedule a downtime ASAP and reset the active supervisor engine.

Error Message    C4K_REDUNDANCY-2-HANDSHAKE_TIMEOUT_STANDBY: The handshake messaging 
between standby and active has not yet started.

Explanation    The initial handshake message exchange between standby and active supervisor engines has not yet started. If the active supervisor engine has not completed its initialization, this message may be seen temporarily on the standby supervisor engine. This condition will correct itself once the active supervisor engine initialization is complete. If problems persist after the active supervisor engine is initialized then redundancy will not work.

Recommended Action    Please schedule a downtime ASAP and reset the active supervisor engine.

Error Message    C4K_REDUNDANCY-2-POSTFAIL_RESET:POST failure on ACTIVE supervisor 
detected. [char]

Explanation    The active supervisor engine failed POST but detected the standby supervisor engine at bootup. It is attempting to reset itself so that the standby supervisor engine can take over as the new active supervisor engine.

Recommended Action    You may need to replace the supervisor engine that failed POST. Contact your technical support representative.

Error Message    C4K_REDUNDANCY-2-INCOMPATIBLE_SUPERVISORS: [char]

Explanation    For proper operation of redundancy, the supervisor engines must be of the same model. In this condition redundancy operations are not available and the standby supervisor engine is disabled because the supervisor engines present are of different models.

Recommended Action    Configure the hardware so that the active and standby supervisor engines are of the same model.

Error Message    C4K_REDUNDANCY-2-IOS_VERSION_CHECK_FAIL: [char]

Explanation    The active and standby supervisor engine software is different. In this condition, redundancy operations are not guaranteed.

Recommended Action    Configure the active and standby supervisor engines to use the same version of software.

Error Message    C4K_REDUNDANCY-2-IOS_VERSION_INCOMPATIBLE:[char]

Explanation    The system detected an incompatible redundancy condition. The active supervisor engine is running Cisco IOS Release 12.2 or later releases and the standby supervisor engine is running Cisco IOS Release 12.1. The system will reset the standby supervisor engine.

Recommended Action    Configure the switch so that the active and standby supervisor engines are running the same release of Cisco IOS software.

Error Message    C4K_REDUNDANCY-2-NON_SYMMETRICAL_REDUNDANT_SYSTEM: [char]

Explanation    The active and standby supervisor engine hardware is different. In this condition, redundancy operations are not guaranteed.

Recommended Action    Configure the hardware so that the active and standby supervisor engines are identical.

Error Message    C4K_REDUNDANCY-2-POSTFAIL:POST failure on [char] supervisor detected. 
[char]

Explanation    The active supervisor engine failed POST. The current standby supervisor engine resets the current active supervisor engine to standby and attempts to become the active supervisor engine. If the standby supervisor engine failed POST, then it will suspend at bootup and stay there. During this time if the active supervisor engine fails, then the standby supervisor engine will also reboot because it is not a fully functional standby supervisor engine at this point.

Recommended Action    Run offline diagnostics on the failed supervisor engine to isolate the problem.

Error Message    C4K_REDUNDANCY-2-POSTFAIL_RESET:POST failure on ACTIVE supervisor 
detected. [char]

Explanation    The active supervisor engine failed POST but detected the standby supervisor engine at bootup. The active supervisor engine will reset itself so that the standby supervisor engine can take over as the new active supervisor engine.

Recommended Action    Run offline diagnostics on the failed supervisor engine to isolate the failure. Immediate action is not needed for the switch to operate, but redundancy will not be available until there is a second functional supervisor engine.

REDUNDANCY-3

Error Message    C4K_REDUNDANCY-3-COMMUNICATION: Communication with the peer Supervisor  
has been [char]

Explanation    The status of the peer supervisor engine communication path changed.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-3-NOT_READY_FOR_SWITCHOVER: The active Supervisor 
failed but standby supervisor cannot initiate  Switchover activity. Resetting 
standby Supervisor.

Explanation    The standby supervisor engine is currently in an intermediate state and cannot take over for the primary supervisor engine.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-3-PEER_RELOAD: The peer Supervisor is being reset 
because [char]

Explanation    The supervisor engine was reset for the reason specified by [char]. See the reported error message for the specific reason. This allows recovery from an indeterminate standby state.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-3-SIMPLEX_MODE: The peer Supervisor has been lost

Explanation    The peer supervisor engine is absent, and the switch shifted to nonredundant mode.

Recommended Action    This is an informational message only. No action is required.

REDUNDANCY-4

Error Message    C4K_REDUNDANCY-4-CONFIGSYNCFAIL:Persistent-config Sync to Standby 
supervisor failed.

Explanation    The active supervisor engine failed to receive a confirmation message from the standby supervisor engine. There is a potential problem with the standby supervisor engine.

Recommended Action    Contact your technical support representative.

Error Message    C4K_REDUNDANCY-4-KEEPALIVE_WARNING: Keepalive messages from peer 
Supervisor are  missing for [dec] seconds

Explanation    Keepalive messages have not been sent from the peer supervisor engine. If the situation persists and the keepalive messages do not resume, the peer supervisor engine will eventually be reset. This message is logged for every third missed keepalive message.

Recommended Action    This is an informational message only. No action is required.

REDUNDANCY-5

Error Message    C4K_REDUNDANCY-5-CALENDAR: The calendar has been successfully 
synchronized to the standby   supervisor for the first time

Explanation    The calendar was successfully synchronized to the standby supervisor engine for the first time.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-5-CALENDAR_RATELIMIT: The calendar has been 
successfully synchronized to the standby supervisor [dec] times since last 
calendar syslog

Explanation    The calendar was successfully synchronized to the standby supervisor engine the specified number of times.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-5-CONFIGSYNC:The [char] has been successfully 
synchronized to the standby supervisor

Explanation    The configuration was successfully synchronized to the standby supervisor engine. [char] can be either a private configuration or a startup configuration.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-5-CONFIGSYNC_RATELIMIT:The [char] has been 
successfully synchronized to the standby supervisor

Explanation    The configuration was successfully synchronized to the standby supervisor engine. This is a rate-limited message. These messages are logged at 1-minute intervals, rather than continuously as with many other messages.

Recommended Action    This is an informational message only. No action is required.

REDUNDANCY-6

Error Message    C4K_REDUNDANCY-6-ACTIVESUPNOTFOUND:Active supervisor not found.

Explanation    This message is displayed on the redundant supervisor engine when it fails to communicate with the active supervisor engine.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-6-ATTEMPTINGTOBECOMEACTIVE:
Attempting to become active supervisor.

Explanation    This message is displayed on the standby supervisor engine when it fails to communicate with the active supervisor engine and attempts to take over as the active supervisor engine.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-6-DUPLEX_MODE: The peer Supervisor has been detected

Explanation    A peer supervisor engine was detected, and the switch shifted to duplex mode.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-6-INIT:Initializing as [char] supervisor

Explanation    A supervisor engine that you are connected to is currently initializing as either the active or standby supervisor engine.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-6-MODE:[char] supervisor initializing for [char] mode

Explanation    The supervisor engine that you are not directly connected to is currently initializing as either the active or standby supervisor engine in RPR mode.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_REDUNDANCY-6-SWITCHOVER:Switchover activity detected

Explanation    The standby supervisor engine detected switchover activity.

Recommended Action    This is an informational message only. No action is required.

S2W Messages

This section contains the Calendar (SERVICECARDMAN) messages.

Error Message    C4K_S2W-4-READCALENDARERR: Calendar read operation Failed

Explanation    The calendar read operation failed.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_S2W-4-STARTCALENDAROSCILLATORERR: Failed to start the calendar

Explanation    The calendar operation failed to start.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_S2W-4-WRITECALENDARERR: Calendar write operation Failed

Explanation    The system was unable to write to the calendar.

Recommended Action    This is an informational message only. No action is required.

SFF8472 Messages

This section contains the floating-point subsystem (SFF8472) messages.

SFF8472-2

Error Message    SFF8472-2-NOMEM: Not enough memory available for [char]

Explanation    The SFF8472 subsystem could not obtain the memory that it needed.

Recommended Action    Contact your technical support representative.

SFF8472-3

Error Message    SFF8472-3-INTERNAL_ERROR: [char]

Explanation    The SFF8472 subsystem encountered an internal software error. The error message contains text that can be used to help identify the cause of the problem.

Recommended Action    Contact your technical support representative.

Error Message    SFF8472-3-UNEXPECTEDEVENT: Process received unknown event (maj [hex] 
min [hex]).

Explanation    A process received an event it did not know how to handle. A process can register to be notified when various events occur in the router.

Recommended Action    Contact your technical support representative.

SFF8472-5

Error Message    SFF8472-5-THRESHOLD_VIOLATION: [char]: [char]; Operating value: [char]

Explanation    There was a threshold violation as specified in the message.

Recommended Action    Contact your technical support representative.

SFF8472_FLOAT

Error Message    SFF8472_FLOAT-3-INTERNAL_ERROR: [char]

Explanation    The SFF8472 floating-point subsystem encountered an internal software error. The error message contains text that can be used to help identify the cause of the problem.

Recommended Action    Contact your technical support representative.

SPANTREE Messages

This section contains the Spanning Tree Protocol (SPANTREE) messages.

SPANTREE-2

Error Message    SPANTREE-2-PVSTSIM_OK: PVST Simulation inconsistency cleared on port 
[char].

Explanation    The listed interface is no longer receiving PVST BPDUs advertising information inconsistent with the CIST port information. The PVST simulation inconsistency is cleared and the interface returns to normal operation.

Recommended Action    This is an informational message only. No action is required.

Error Message    
Error Message    SPANTREE-2-BLOCK_BPDUGUARD:Received BPDU on port [char] with BPDU 
Guard enabled. Disabling port.

Explanation    A BPDU was received in the specified interface that has the spanning tree BPDU guard feature enabled. As a result, the interface was administratively shut down.

Recommended Action    Remove the device sending BPDUs, or disable the BPDU guard feature. BPDU guard can be locally configured on the interface or globally configured on all ports that have PortFast enabled. After you resolve the conflict, reenable the interface by entering the no shutdown command in interface configuration mode.

Error Message    SPANTREE-2-BLOCK_PVID_LOCAL: Blocking [char] on [char]. Inconsistent 
local vlan.

Explanation    The spanning tree port that is associated with the listed spanning tree instance [char] and interface [char] is held in spanning tree blocking state until the port VLAN ID (PVID) inconsistency is resolved. The listed spanning tree instance is that of the native VLAN ID of the listed interface.

Recommended Action    Verify that the configuration of the native VLAN ID is consistent on the interfaces at each end of the 802.1Q trunk connection. When the configuration is consistent, spanning tree automatically unblocks the interfaces.

Error Message    SPANTREE-2-BLOCK_PVID_PEER: Blocking [char] on [char]. Inconsistent 
peer vlan.

Explanation    The spanning tree port (with spanning-tree port ID [char]) that is associated with the listed instance and interface is held in blocking state until the port VLAN ID (PVID) inconsistency is resolved. The listed spanning tree instance is that of the native VLAN ID of the interface on the peer switch to which the listed interface is connected.

Recommended Action    Verify that the configuration of the native VLAN ID is consistent on the interfaces on each end of the 802.1Q trunk connection. When corrected, spanning tree automatically unblocks the interfaces.

Error Message    SPANTREE-2-CHNL_MISCFG:Detected loop due to etherchannel 
misconfiguration of [chars] [chars]

Explanation    A misconfigured channel group (with channel group ID [chars]) was detected. For example, the ports of one side of the EtherChannel either are not configured to be in the channel or failed to bundle, while ports on the other side of the EtherChannel are successfully bundled.

Recommended Action    Locate the misconfigured local ports by entering the show interfaces status err-disabled command. Check the EtherChannel configuration on the remote device by entering the show etherchannel summary command on the remote device. After the configuration is corrected, enter the shutdown/no shutdown command on the associated port-channel interface.

Error Message    SPANTREE-2-LOOPGUARD_BLOCK: Loop guard blocking port [char] on [char].

Explanation    The spanning tree message age timer expired, because no BPDUs were received from the designated bridge. Because this condition could be caused by an unidirectional link failure, the interface is put into blocking state and marked as loop guard inconsistent in order to prevent possible loops from being created.

Recommended Action    Use the show spanning-tree inconsistentports command to review the list of interfaces with loop guard inconsistencies. Determine why devices that are connected to the listed ports are not sending BPDUs. One reason could be that they do not run the Spanning Tree Protocol; in this case, you should disable loop guard in the inconsistent interfaces or start the Spanning Tree Protocol on the other side of the links, depending on the context. Another reason could be a failure in the cable. If the link has a failure that makes it unidirectional (you can transmit, but you cannot receive), you should replace the old cable with a new cable.

Error Message    SPANTREE-2-LOOPGUARD_CONFIG_CHANGE: Loop guard [char] on port [char].

Explanation    There was a change in the spanning tree loop guard configuration for the listed interface. When enabled, the interface will be put into blocking state and marked as loop guard inconsistent when the message age timer expires because no BPDUs were received from the designated bridge. This feature is used to detect unidirectional links.

Recommended Action    Verify that this is the desired configuration for the listed interface. Correct it if this is not the desired configuration; otherwise, no further action is required.

Error Message    SPANTREE-2-LOOPGUARD_UNBLOCK: Loop guard unblocking port [char] on 
[char].

Explanation    The listed interface received a BPDU, and if the inconsistency was due to an unidirectional link failure, the problem does not exist anymore. The loop guard inconsistency is cleared for the interface, which is taken out of the blocking state.

Recommended Action    This is an informational message only. No action is required.

Error Message    SPANTREE-2-PVSTSIM_FAIL: Blocking [char] port [char]: Inconsitent 
[char] PVST BPDU received on VLAN [dec]

Explanation    When a PVST+ switch is connected to an MST switch, the CIST (MSTOO) becomes the root for all PVST+ spanning trees. Looping occurs if any PVST+ spanning tree has a root with a better preference than IST. To prevent looping, the port, which is on the MST switch that receives the superior message from the PVST+ side, is blocked by root guard.

When STP is converging after a new switch or a switch port is added to the topology, this condition occurs transiently. The port unblocks automatically in such cases.

Recommended Action    If the port remains blocked, identify the root bridge as reported in the message, and configure a worse priority for the VLAN spanning tree. There could be better PVST roots than the message indicates, and the port will not recover until all such roots are cleared. If you are unsure whether the roots are cleared, disable and enable the port again.

Error Message    SPANTREE-2-RECV_1Q_NON_1QTRUNK: Received 802.1Q BPDU on non 802.1Q 
trunk [char] [char].

Explanation    A Shared Spanning Tree Protocol (SSTP) bridge protocol data unit (BPDU) was received on the listed interface. The interface was in trunk mode but was not using 802.1Q encapsulation. The interface ID is [char].

Recommended Action    Verify that the configuration and operational state of the listed interface and the interface to which it is connected are in the same mode (access or trunk). If the mode is trunk, verify that both interfaces have the same encapsulation (ISL or 802.1Q). Once these parameters are consistent, spanning tree automatically unblocks the interface.

Error Message    SPANTREE-2-RECV_BAD_TLV:Received SSTP BPDU with bad TLV on 
[char][char].

Explanation    The listed interface received an SSTP BPDU that was missing the VLAN ID tag. The BPDU is discarded. [char] is the interface ID.

Recommended Action    If the error message reappears, copy the message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    SPANTREE-2-RECV_PVID_ERR: Received BPDU with inconsistent peer vlan id 
[dec] on [char] [char]

Explanation    The listed interface received an SSTP BPDU that is tagged with a VLAN ID that does not match the VLAN ID on which the BPDU was received. This condition occurs when the native VLAN is not consistently configured on both ends of an 802.1Q trunk. [dec] is the VLAN ID. The interface ID is [char].

Recommended Action    Verify that the configuration of the native VLAN ID is consistent on the interfaces on each end of the 802.1Q trunk connection. Once the configuration is consistent, spanning tree automatically unblocks the interfaces.

Error Message    SPANTREE-2-ROOTGUARD_BLOCK: Root guard blocking port [char] on [char].

Explanation    A BPDU was received on the listed interface that advertised a spanning tree root bridge that was superior to the one already in use. The interface is put into a blocking state and marked as root guard inconsistent to prevent a suboptimal spanning tree topology from forming.

Recommended Action    Enter the show spanning-tree inconsistentports command to review the list of interfaces with root guard inconsistencies. Determine why devices that are connected to the listed ports are sending BPDUs with a superior root bridge, and then take action to prevent further occurrences. Once the invalid BPDUs have been stopped, the interfaces automatically recover and resume normal operation. By looking at the configuration, ensure that it is appropriate to enable root guard on the interface.

Error Message    SPANTREE-2-ROOTGUARD_CONFIG_CHANGE: Root guard [char] on port [char].

Explanation    There was a change in the spanning tree root guard configuration for the listed interface. If root guard is enabled, any BPDU that is received on the interface that advertises a superior spanning tree root bridge to the one that is already in use will cause the interface to be put into blocking state and marked as root guard inconsistent.

Recommended Action    Verify that this is the correct configuration for the listed interface. If this is not the correct configuration, change the configuration to one that is appropriate for the interface.

Error Message    SPANTREE-2-ROOTGUARD_UNBLOCK:Root guard unblocking port [char] on 
[char].

Explanation    The listed interface is no longer receiving BPDUs that are advertising a superior root bridge. The root guard inconsistency is cleared for the interface and then is taken out of the blocking state if appropriate.

Recommended Action    This is an informational message only. No action is required.

Error Message    SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking [char] on [char]. Port 
consistency restored.

Explanation    The port VLAN ID and/or port type inconsistencies have been resolved. The Spanning Tree Protocol will unblock the listed interface of the spanning tree instance. The interface ID is [char].

Recommended Action    This is an informational message only. No action is required.

SPANTREE-3

Error Message    SPANTREE-3-BAD_PORTNUM_SIZE:Rejected an attempt to set the port number 
field size to [dec] bits (valid range is [dec] to [dec] bits).

Explanation    The spanning tree port identifier is a 16-bit field that is, by default, divided evenly between the port priority and the port number. Each subfield is 8 bits wide, allowing the port number field to represent port numbers between 1 and 255. On systems with more than 255 ports, the STP subsystem must increase the size of the port number portion of the port ID to support the greater number of ports. This condition occurs at system initialization because the maximum number of ports on a particular platform will not change. This error occurs because of an error in the platform-specific code that caused it to request more (or fewer) bits than were possible.

Recommended Action    Contact your technical support representative.

Error Message    SPANTREE-3-PORT_SELF_LOOPED: [char] disabled.- received BPDU src mac 
([mac-addr])  same as that of interface

Explanation    A BPDU with a source MAC address that matches the address assigned to the listed interface was received. A port looped back on itself, possibly due to a diagnostic cable that was plugged into the interface. The interface is administratively shut down. [char] is the interface ID.

Recommended Action    Check the interface configuration and any cable that is plugged into the interface. Once the problem is resolved, reenable the interface by entering the no shutdown command on the interface.

Error Message    SPANTREE-3-PRESTD_NEIGH: pre-standard MST interaction not configured 
([char]). Please

Explanation    The switch has received a pre-standard MST BPDU transmission on a port that is not configured for it. The switch will automatically adjust its mode of operation on this port and will start sending pre-standard BPDUs. However, this auto-detection of pre-standard neighbors is not 100% accurate, and it is recommended to explicitly configure the port for pre-standard MST BPDU transmission. This warning message is displayed only once.

Recommended Action    Use the spanning-tree mst pre-standard configuration command on all ports that are connected to switches running Cisco's pre-standard version of MST. Migrate all switches in the network to the IEEE standard MST version when it is possible.

SPANTREE-4

Error Message    SPANTREE-4-PORT_NOT_FORWARDING: [char] [char] [char] [char] 

Explanation    The specified interface is not in the forwarding state and forwarding packets.

Recommended Action    Contact your technical support representative.

SPANTREE-5

Error Message    SPANTREE-5-EXTENDED_SYSID:Extended SysId [char] for type [char]

Explanation    The extended system ID feature was either enabled or disabled for the given type of spanning tree. If the feature was enabled, the spanning tree instance identifier is stored in the lower portion of the bridge ID priority field; this will cause the allowed values for the bridge priority to be limited to the range of 0 to 61,440, in increments of 4096. If the feature was disabled, the bridge ID priority field consists entirely of the configured priority, but some spanning tree features might not be available on a given platform (for example, 4096 VLAN support).

Recommended Action    This is an informational message only. No action is required.

Error Message    SPANTREE-5-ROOTCHANGE: Root Changed for [char] [dec]:  New Root Port 
is [char]. New Root Mac Address is [mac-addr]

Explanation    The root changed for an instance of spanning tree.

Recommended Action    This is an informational message only. No action is required.

Error Message    SPANTREE-5-TOPOTRAP: Topology Change Trap for [char] [dec]

Explanation    A trap was generated to indicate the change in topology.

Recommended Action    This is an informational message only. No action is required.

SPANTREE-6

Error Message    SPANTREE-6-PORT_STATE: Port [char] instance [dec] moving from [char] 
to [char]

Explanation    The spanning tree port changed to another state.

Recommended Action    This is an informational message only. No action is required.

SPANTREE-7

Error Message    SPANTREE-7-BLOCK_PORT_TYPE: Blocking [char] on [char]. Inconsistent 
port type.

Explanation    The listed interface is being held in spanning tree blocking state until the port type inconsistency is resolved. The port ID is [char].

Recommended Action    Verify that the configuration and operational state of the listed interface and that of the interface to which it is connected are in the same mode (access or trunk). If the mode is trunk, verify that both interfaces have the same encapsulation type (ISL or 802.1Q). When these parameters are consistent, spanning tree automatically unblocks the interface.

Error Message    SPANTREE-7-RECV_1Q_NON_TRUNK: Received 802.1Q BPDU on non trunk [char] 
[char].

Explanation    An SSTP BPDU was received on the listed interface, which is not an operational trunking interface. The interface ID is [char].

Recommended Action    Verify that the configuration and operational state of the listed interface and that of the interface to which it is connected are in the same mode (access or trunk). If the mode is trunk, verify that both interfaces have the same encapsulation type (none, ISL, or 802.1Q). Once these parameters are consistent, spanning tree automatically unblocks the interface.

Error Message    SPANTREE-7-PORTDEL_SUCCESS: [char] deleted from Vlan [dec]

Explanation    The interface was deleted from the specified VLAN.

Recommended Action    This is an informational message only. No action is required.

SPANTREE_FAST

Error Message    SPANTREE_FAST-7-PORT_FWD_UPLINK: [char] [char] moved to Forwarding 
(UplinkFast).

Explanation    The listed interface was selected as the new root port for the listed spanning tree instance.

Recommended Action    This is an informational message only. No action is required.

SPANTREE_VLAN_SW Messages

This section contains the spanning tree fast convergence (SPANTREE_VLAN_SW) message.

Error Message    SPANTREE_VLAN_SW-2-MAX_INSTANCE:Platform limit of [dec] STP instances 
exceeded. No instance created for [char] (port [char]).

Explanation    The number of currently active VLAN spanning tree instances reached a platform-specific limit. No additional VLAN instances will be created until the number of instances drops below that limit.

Recommended Action    Reduce the number of currently active spanning tree instances by either disabling some of the instances or deleting the VLANs that are associated with them. You need to manually enable those spanning trees that cannot be created due to limited instances.

Supervisor Messages

This section contains the supervisor engine specific (C4K_SUPERVISOR) messages.

Error Message    C4K_SUPERVISOR-0-SUPNOTSUPPORTEDINCHASSIS: The WS-X4013+TS supervisor 
is not supported in chassis type [char]

Explanation    The WS-X4013+TS is supported only in the Catalyst 4503 chassis. Either the WS-X4013+TS supervisor engine is in a chassis with more than 3 slots, which is a misconfiguration and not supported, or the chassis' serial EEPROM is programmed incorrectly and contains the wrong chassis type.

Recommended Action    If this chassis has more than 3 slots, the WS-X4013+TS is not supported in it. If the chassis has 3 slots, and you see this message, collect the output of the show idprom chassis command and call Cisco TAC. This chassis needs to be returned to Cisco.

Error Message    C4K_SUPERVISOR-3-SUPOCTALPHYMDIOREADERR:Failed to perform read 
operation on Octal Serdes at address [dec] for the register at address [dec]

Explanation    Unable to read the Octal Serdes on the supervisor engine.

Recommended Action    If this continues to happen, please contact your technical support representative to replace the supervisor engine.

Error Message    C4K_SUPERVISOR-3-POWERSUPPLYSTATUSREADFAILED: Failed to read power 
supply [dec]'s status register

Explanation    Reading the power supply status register failed.

Recommended Action    Try reinserting the power supply. If the problem persists, hot swap it with a new power supply.

Error Message    C4K_SUPERVISOR-3-SUPOCTALPHYMDIOREADERR: Failed to perform read 
operation on Octal Serdes at address [dec] for the register at address [dec]

Explanation    There was an error with the Octal Serdes on the supervisor engine.

Recommended Action    If this continues to happen, please contact your technical support representative to replace the supervisor engine.

STORM_CONTROL Messages

This section contains the broadcast storm control (STORM_CONTROL) messages.

Error Message    STORM_CONTROL-3-FILTERED: A [char] storm detected on [char]. A packet 
filter action has been applied on the interface.

Explanation    The amount of traffic detected on the interface exceeded the configured threshold values. The system filters excess traffic when a packet is received. The system is not forwarding packet traffic.

Recommended Action    Determine and fix the root cause of the excessive traffic on the interface.

Error Message    STORM_CONTROL-3-SHUTDOWN: A packet storm was detected on [char]. The 
interface has been disabled.

Explanation    The amount of traffic detected on the interface exceeded the configured threshold values. Because the interface was configured to be shut down if a packet storm event is detected, it was placed in an errdisable state.

Recommended Action    If automatic recovery is preferred, the errdisable recovery mechanism can be used. Determine and fix the root cause of the excessive traffic on the interface.

STORE Messages

This section contains the storage (STORE) message.

Error Message    C4K_STORE-2-OUTOFCHUNKS:Out of chunks of memory

Explanation    The system has insufficient memory.

Recommended Action    Reboot the switch. If this message reoccurs, add additional memory.

SUPERVISOR Messages

This section contains the supervisor engine (SUPERVISOR) messages.

SUPERVISOR-2

Error Message    C4K_SUPERVISOR-2-MUXBUFFERNOTPRESENT:Mux buffer (WS-X4K-MUX) [dec] is 
not present

Explanation    The WS-X4K-MUX mux buffer for slot [dec] is either not connected to the backplane properly or is not present. If the switching module present in this slot cannot be identified, its SEEPROM cannot be read and it will be unusable.

Recommended Action    Reseat the mux buffers in the backplane. If the message persists, contact your technical support representative.

SUPERVISOR-3

Error Message    C4K_SUPERVISOR-3-BACKPLANESEEPROMREADFAILED:Failed to read 
backplane's serial eeprom, read [dec], expected size [dec]

Explanation    A failure occurred when reading the backplane serial EEPROM.

Recommended Action    Power cycle the switch. If the problem persists, contact your technical support representative. You will probably need to return the backplane for repair.

Error Message    C4K_SUPERVISOR-3-CLOCKMODULESEEPROMREADFAILED: Failed to read clock 
module's seeprom

Explanation    A failure occurred while reading the clock module serial EEPROM. This message should occur only in a prototype switch used in an early field trial.

Recommended Action    Check the chassis serial EEPROM information. Contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_SUPERVISOR-3-FANTRAYREADFAILED: Failed to read system fan tray 
status register from hardware

Explanation    The fan tray presence was detected, but the system failed to read the fan tray status register contents.

Recommended Action    If this message appears only once, this could be a transient error and no action is required. If this message appears repeatedly (once every 10 minutes), replace the system fan tray.

Error Message    C4K_SUPERVISOR-3-FANTRAYSEEPROMREADFAILED: Failed to read fan tray's 
seeprom

Explanation    A failure occurred while reading the system fan tray serial EEPROM. This message should occur only in a prototype switch used in an early field trial.

Recommended Action    Check the chassis serial EEPROM information. Contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_SUPERVISOR-3-MUXBUFFERLOOPBACKFAILED: Failed to put [char] 
supervisor's module [dec] muxbuffers in loopback

Explanation    The serial-to-wire write operation to put the line card mux buffers in loopback failed. This might indicate problems with the line card mux buffers in the Catalyst 4500 series chassis.

Recommended Action    Power cycle the switch. If the serial EEPROM is still invalid, contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_SUPERVISOR-3-MUXBUFFERREADLOOPBACKFAILED: Failed to read whether 
[char] supervisor's module [dec] muxbuffers are in loopback

Explanation    The serial-to-wire write operation to put the line card mux buffers in loopback failed. This might indicate problems with the line card mux buffers in the Catalyst 4500 series chassis.

Recommended Action    Power cycle the switch. If the serial EEPROM is still invalid, contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_SUPERVISOR-3-MUXBUFFERSEEPROMREADFAILED: Failed to read mux buffer 
[dec]'s serial eeprom

Explanation    A failure occurred while reading the mux buffer serial EEPROM.

Recommended Action    Power cycle the switch. If the serial EEPROM is still invalid, contact your technical support representative. You may need to return some switch components for repair or replacement.

Error Message    C4K_SUPERVISOR-3-NETFLOWCARDSEEPROMINVALID: Invalid Netflow Services 
Card seeprom data

Explanation    The serial EEPROM on the NetFlow Services Card cannot be read or was not programmed.

Recommended Action    For more information, enter the sprom read nffc command at the ROMMON prompt.

Error Message    C4K_SUPERVISOR-3-NETFLOWCARDSEEPROMREADFAILED: Netflow Services Card 
seeprom read failed

Explanation    A reading of the serial EEPROM on the NetFlow Services Card failed.

Recommended Action    For more information, enter the sprom read nffc command at the ROMMON prompt.

Error Message    C4K_SUPERVISOR-3-NETFLOWCARDSEEPROMUNKNOWNTYPE: Unknown Netflow 
Services Card revision: Read fru major/minor ([hex],[hex]) but expected 
([hex],[hex]).

Explanation    The serial EEPROM on the NetFlow Services Card has a revision that is not compatible with this release of software. The card will be ignored.

Recommended Action    For more information, enter the sprom read nffc command at the ROMMON prompt.

Error Message    C4K_SUPERVISOR-3-POWERSUPPLYSTATUSREADFAILED:Failed to read power 
supply [dec]'s status register

Explanation    Reading the power supply status register failed.

Recommended Action    Try reinserting the power supply. If the message persists, hot swap it with a new power supply.

Error Message    C4K_SUPERVISOR-3-POWERSUPPLYSEEPROMREADFAILED: Failed to read power 
supply [dec]'s serial eeprom

Explanation    A failure occurred while reading the power supply serial EEPROM.

Recommended Action    Reinsert the power supply. If that does not work, replace the old power supply with a new power supply.

Error Message    C4K_SUPERVISOR-3-RETIMERDISABLEFAILED:Failed to disable the retimer of 
the active supervisor's uplink.

Explanation    The retimer on the active supervisor engine cannot be initialized. In a redundant system, you might see packets that are transmitted out the active supervisor engine's nonactive uplink.

Recommended Action    Disconnect the second uplink on the active supervisor engine.

Error Message    C4K_SUPERVISOR-3-RETIMERINITFAILED:Failed to initialize the retimer of 
the active supervisor's uplink.

Explanation    The retimer on the active supervisor engine cannot be initialized. In a redundant system, you might see packets that are transmitted out the active supervisor engine's nonactive uplink.

Recommended Action    Disconnect the second uplink on the active supervisor engine.

Error Message    C4K_SUPERVISOR-3-SEEPROMREADFAILED:Failed to read supervisor's serial 
eeprom, try reinserting supervisor

Explanation    A reading of the supervisor engine's serial EEPROM failed. The read might fail if the module is not seated correctly in the slot.

Recommended Action    Remove and reinsert the module. If that does not work, power cycle the switch. If the read still fails, contact your technical support representative. You may need to return some switch components for repair or replacement.

SUPERVISOR-4

Error Message    C4K_SUPERVISOR-4-INLINEVOLTAGEOUTOFRANGE:Output voltage of the 
on-board inline power convertor on this  board is  [char] and is outside the 
expected  range of  [char]

Explanation    This message should only occur in systems using a Supervisor Engine II-Plus TS. The output voltage of the on-board inline power converter is outside its expected valid range. This condition can occur because of failed PoE components, one or more powered devices drawing more power than expected, or because of problems with the 12 V output of the system power supply.

Recommended Action    Use the show power detail and show power inline module 1 commands to verify that the devices drawing PoE are using the expected amount of power, and disconnect them if they are drawing more than desired. If the power supply LEDs are not green, verify at the source that the system power input is correct. If the problem persists, contact your technical support representative. You will probably need to replace the supervisor engine.

Error Message    C4K_SUPERVISOR-4-OTHERSUPERVISORACTIVEDEBOUNCE:Other supervisor is 
still holding hardware lock

Explanation    This condition is detected when the redundancy register incorrectly indicates that the other supervisor engine is holding a lock. This error is probably caused by hardware signal latency. Unless there is a real hardware failure, the switch automatically recovers from this state. If there is a persistent hardware failure, this message appears four times.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SUPERVISOR-4-SUPMGMTMACFATALRXERR:Supervisor MAC device type 
[hex] reset due to a fatal Rx error

Explanation    An error occurred with the out-of-band management port on the supervisor engine.

Recommended Action    This is an informational message only. No action is required.

SUPERVISOR-7

Error Message    C4K_SUPERVISOR-7-BACKPLANESEEPROMWRITEFAILED:Failed to write 
backplane's serial eeprom

Explanation    The writing of the backplane serial EEPROM failed.

Recommended Action    Power cycle the switch.

Error Message    C4K_SUPERVISOR-7-SEEPROMWRITEFAILED:Failed to write supervisor's 
serial eeprom

Explanation    The software was unable to write to the supervisor engine serial EEPROM.

Recommended Action    Remove and reinsert the module. If this message reappears, reboot the switch. If the switch is still unable to write to the EEPROM, contact your technical support representative.

SWITCH-QOS-TB Messages

This section contains the Switch QoS Manager (SWITCH-QOS-TB) messages.

Error Message    SWITCH_QOS_TB-5-TRUST_DEVICE_DETECTED: [char] detected on port [char]

Explanation    Software detected that a device matching the trusted device boundary setting for the interface and changed the trust state for the interface to trusted.

Recommended Action    This is an informational message only. No action is required.

Error Message    SWITCH_QOS_TB-5-TRUST_DEVICE_LOST: [char] no longer detected on port 
[char], port set to untrusted

Explanation    The system lost contact with a trusted device and changed the trust state for the interface to untrusted.

Recommended Action    This is an informational message only. No action is required.

SW_DAI Messages

This section contains the dynamic ARP inspection (DAIMAN) messages.

SW_DAI-4

Error Message    SW_DAI-4-ACL_DENY: [dec]Invalid ARPs (Req) on [chars], vlan [dec]. 

Explanation    The switch received ARP packets that are considered invalid by ARP inspection. The packets are invalid, and their presence indicates that administratively denied packets are in the network. This log message generates when packets have been denied by ACLs either explicitly or implicitly (with static ACL configuration). The presence of these packets indicates a possible "man-in-the-middle" attacks in the network.

Recommended Action    To stop these messages from generating, find the source host of these packets and stop the host from sending them.

Error Message    SW_DAI-4-DHCP_SNOOPING_DENY: [dec] Invalid ARPs (Req) on [chars], vlan 
[chars]. 

Explanation    The switch received ARP packets that are considered invalid by ARP inspection. The packets are invalid, and their presence may be an indication of "man-in-the-middle" attacks that are attempted in the network. This message is logged when the IP address and MAC address binding for the sender on the received VLAN is not listed in the DHCP snooping database.

Recommended Action    To stop these messages from generating, find the source host of these packets and stop the host from sending them.

Error Message    SW_DAI-4-INVALID_ARP: [dec] Invalid ARPs (Req) on [chars], vlan 
[chars].

Explanation    The switch received ARP packets that are considered invalid by ARP inspection. The packets are invalid and do not pass one or more of the source MAC address, destination MAC address, or IP address validation checks. A packet was denied because the source MAC address, destination MAC address, or IP validation failed.

Recommended Action    To stop these messages from generating, find the source host of these packets and stop the host from sending them.

Error Message    SW_DAI-4-PACKET_BURST_RATE_EXCEEDED: [dec] packets received in [dec] 
seconds on [char].

Explanation    The switch received [dec] number of ARP packets in the specified burst interval. The interface was in the errdisabled state and the switch received the packets at a rate higher than the configured packet rate for every second over the configured burst interval. The message is logged just before the interface entered the errdisabled state and if the configured burst interval is more than one second.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_DAI-4-PACKET_RATE_EXCEEDED: [dec] packets received in [dec] 
milliseconds on [char].

Explanation    The switch received [dec] number of ARP packets in the specified duration on the given interface above the exceeded packet rate. This message is logged just before the interface entered the errdisabled state and when the burst interval is set to one second.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_DAI-4-SPECIAL_LOG_ENTRY: [dec] Invalid ARP packets [%CC]

Explanation    The switch received [dec] number of ARP packets that the ARP inspection considers invalid. The packets are invalid, and their presence may be an indication of "man-in-the-middle" attacks attempted on the network. This message displays when the rate of incoming packets exceed the DAI logging rate.

Recommended Action    This is an informational message only. No action is required.

SW_DAI-6

Error Message    SW_DAI-6-ACL_PERMIT: [dec] ARPs (Req) on [chars], vlan [chars].

Explanation    The switch received ARP packets that have been permitted because of an ACL match.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_DAI-6-DHCP_SNOOPING_PERMIT: [dec] ARPs (Req) on [chars], vlan 
[chars]

Explanation    The switch received ARP packets that have been permitted because the IP and MAC address for the sender match against the DHCP snooping database for the received VLAN.

Recommended Action    This is an informational message only. No action is required.

SW-VLAN Messages

This section contains the Switch VLAN Manager (SW-VLAN) messages.

SW-VLAN-3

Error Message    SW_VLAN-3-VLAN_PM_NOTIFICATION_FAILURE: VLAN Manager synchronization 
failure with Port Manager over [char]

Explanation    Due to a lack of ready pool space, the VLAN Manager dropped a notification from the Port Manager.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-3-VTP_PROTOCOL_ERROR: VTP protocol code internal error: [char]

Explanation    The VTP protocol code encountered an unexpected error while processing a configuration request, packet, or timer expiration.

Recommended Action    This is an informational message only. No action is required.

SW-VLAN-4

Error Message    SW_VLAN-4-BAD_PM_VLAN_COOKIE_RETURNED: VLAN manager unexpectedly 
received a bad PM VLAN cookie from the Port Manager

Explanation    The VLAN Manager received an upcall from the Port Manager containing a VLAN cookie that translated to a bad VLAN number.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-BAD_STARTUP_VLAN_CONFIG_FILE: Failed to configure VLAN from 
startup-config. Fallback to use VLAN configuration file from non-volatile memory

Explanation    The VLAN software failed to use the VLAN configuration from a startup-config file. The software will use the binary VLAN configuration file in nonvolatile memory.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-BAD_VLAN_CONFIGURATION_FILE: VLAN configuration file 
contained incorrect verification word: [hex]

Explanation    The VLAN configuration file begins with an unrecognized value and might not be a valid VLAN configuration file. The file was rejected.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-BAD_VLAN_CONFIGURATION_FILE_VERSION: VLAN configuration 
file contained unknown file version: [dec]

Explanation    When the VLAN Manager read the VLAN configuration file it contained an unrecognized file version number. This could indicate an attempt to regress to an older version of the VLAN Manager software.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-BAD_VLAN_TIMER_ACTIVE_VALUE: Encountered incorrect VLAN 
timer active value: [char]

Explanation    Due to a software error, a VLAN timer was detected as being active when it should have been inactive or inactive when it should have been detected as being active.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-EXT_VLAN_INTERNAL_ERROR: Extended VLAN manager received an 
internal error [dec] from [char]: [char]

Explanation    The VLAN Manager received an unexpected error code from the extended VLAN configuration software.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-EXT_VLAN_INVALID_DATABASE_DATA: Extended VLAN manager 
received bad data of type [char]: value [dec] from function [char]

Explanation    The extended VLAN Manager received invalid data from an extended VLAN configuration database routine.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-IFS_FAILURE: VLAN manager encountered file operation error: 
call = [char] / file = [char]  / code = [dec] ([char]) / bytes transferred = [dec]

Explanation    The VLAN Manager received an unexpected error return from a Cisco IOS file system call.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-NO_PM_COOKIE_RETURNED: VLAN manager unexpectedly received a 
null [char] type cookie from the Port Manager

Explanation    The VLAN Manager queried the Port Manager for a reference cookie but received a NULL pointer instead.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-STARTUP_EXT_VLAN_CONFIG_FILE_FAILED: Failed to configure 
extended range VLAN from startup-config. Error [char]

Explanation    The VLAN software failed to use extended VLAN configuration in the startup-config file. Configuration information for all extended-range VLANs will be lost when the system boots.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-VLAN_CREATE_FAIL: Failed to create VLANs [char]: [char]

Explanation    The VLANs specified in the error message could not be created. The VLAN manager called a VLAN database routine to create one or more VLANs, but the Port Manager could not complete the VLAN creation requests. A possible cause of this error is that the VLANs already exist in the Port Manager as internal VLANs.

Recommended Action    Contact your technical support representative.

Error Message    SW_VLAN-4-VTP_INTERNAL_ERROR: VLAN manager received an internal error 
[dec] from vtp function [char]: [char]

Explanation    The VLAN Manager received an unexpected error code from the VTP configuration software.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-VTP_INVALID_DATABASE_DATA: VLAN manager received bad data of 
type [char]: value [dec] from vtp database function [char]

Explanation    The VLAN Manager received invalid data from a VTP configuration database routine.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-VTP_INVALID_EVENT_DATA: VLAN manager received bad data of 
type [char]: value [dec] while being called to handle a [char] event

Explanation    The VLAN Manager received invalid data from the VTP configuration software.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-VTP_USER_NOTIFICATION: VTP protocol user notification: 
[char] 

Explanation    The VTP protocol code encountered an unusual diagnostic condition.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-4-VTP_SEM_BUSY: VTP semaphore is unavailable for function 
[char]. Semaphore locked by [char]

Explanation    The VTP database is currently locked by another task and is not available. Retry the operation later.

Recommended Action    Retry the operation later.If the problem persists, contact your technical support representative.

SW-VLAN-6

Error Message    SW_VLAN-6-OLD_CONFIG_FILE_READ: Old version [dec] VLAN configuration 
file detected and read OK. Version [dec] files will be written in the future.

Explanation    The VLAN software detected an old version of the VLAN configuration file format. The VLAN software was able to interpret the file with no problems, but it will create files using the new format in the future.

Recommended Action    This is an informational message only. No action is required.

Error Message    SW_VLAN-6-VTP_MODE_CHANGE: VLAN manager changing device mode from 
[char] to [char].

Explanation    Some switch devices must automatically change VTP device modes upon receipt of a VLAN configuration database containing more than a set number of VLANs, depending on the device. Such a spontaneous conversion occurred, what the previous mode was, and what the current mode is.

Recommended Action    This is an informational message only. No action is required.

SWITCHINGENGINEMAN Messages

This section contains the switching engine management (SWITCHINGENGINEMAN) messages.

SWITCHINGENGINEMAN-2

Error Message    C4K_SWITCHINGENGINEMAN-2-PACKETMEMORYERROR3: Persistent Errors in 
Packet Memory [dec]

Explanation    There is a high rate of persistent errors in packet memory. This condition might indicate a persistent hardware problem.

Recommended Action    If this message persists, use the show platform commands to show results, contact your technical support representative, and provide the representative with the gathered information.

SWITCHINGENGINEMAN-3

Error Message    C4K_SWITCHINGENGINEMAN-3-BADDELIMITER:Recived CPU packet with bad 
delimiter

Explanation    The software expected a delimiter pattern of successive packets but received some other pattern. This condition might be due to a loss of synchronization between the hardware and the software.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHINGENGINEMAN-3-BADLENGTH:Recived CPU packet with bad length

Explanation    The switch received a CPU packet that was either too long or too short.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHINGENGINEMAN-3-CIMPKTBUFPARITYERROR: Parity error in Cim 
Packet Buffer at offset  [dec] 

Explanation    There is a parity error in queue memory. This condition might indicate a transient hardware problem or a more permanent problem. After 128 packet memory and queue memory errors, the switch reboots.

Recommended Action    If you see this message often, reboot the switch.

Error Message    C4K_SWITCHINGENGINEMAN-3-ERRORINTERRUPT: Error condition detected by 
hardware. Interrupt Status [hex]

Explanation    The hardware detected an error condition and raised an interrupt to the software. The interrupt status value indicates the type of error.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHINGENGINEMAN-3-FREELISTMEMORYPARITYERROR: Parity error in 
freelist memory, flm addr=[hex], reg bits=[hex], total errors=%u

Explanation    An error in freelist memory was detected. If this message persists, it may indicate a transient hardware problem, or a more permanent problem leading to memory corruption. After 128 such transmit count errors, the switch will reload.

Recommended Action    If the switch is reloading too often due to this condition, you may need to check for environmental conditions such as RFI or other interference. It may also be necessary to replace the supervisor engine.

Error Message    C4K_SWITCHINGENGINEMAN-3-JUMBOPACKET:Recieved a Jumbo CPU packet

Explanation    The switch received a packet that is larger than 2032 bytes. This large packet is called a jumbo packet.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHINGENGINEMAN-3-NOMEMORYFORRXRING: Not enough memory to 
initialize CPU packets

Explanation    The system ran out of memory while trying to initialize the CPU packet driver.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHINGENGINEMAN-3-PACKETENGINERESTARTED: An error happened in 
the Packet Engine logic

Explanation    The packet engine logic became unstable for unknown reasons.

Recommended Action    Reboot the switch.

Error Message    C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYERROR2: Multiple Errors in 
Packet Memory [dec]

Explanation    Multiple errors in packet memory were detected. If this message persists, it might indicate a hardware problem.

Recommended Action    If this message persists, use the show platform commands to show results, contact your technical support representative, and provide the representative with the gathered information.

Error Message    C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYPARITYERROR: Parity error in 
Packet Memory at address  [dec] , total errors= [dec]

Explanation    There is a parity error in packet memory. This condition might indicate a transient hardware problem or a more permanent problem. After 128 packet memory and queue memory errors, the switch reloads automatically.

Recommended Action    If this message reoccurs, reboot the switch. If the message appears every time the switch boots, run the show diagnostics online command and send the results to your technical support representative.

Error Message    C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYTESTFAILURE:Packet Memory buffer 
test failed!!!  Insufficient packet  buffers are available to continue booting.

Explanation    The packet memory diagnostic bootup test detected too many failures for switch operation to continue.

Recommended Action    Refer to the Release Note attachment in the DDTS for CSCdz57255.

Error Message    C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYTESTPARTIALFAILURE:Packet Memory 
buffer test detected errors with  [dec] % of the packet buffers.  Switch operation 
will continue, with  potentially reduced performance. Use 'show diagnostic result  
module all detail' command to see test results.

Explanation    The packet memory diagnostic bootup test detected failures, but there are still a sufficient number of working buffers to enable switch operation.

Recommended Action    Use the show diagnostic result module all detail command to see the test results. Refer to the Release Note attachment in the DDTS for CSCdz57255.

Error Message    C4K_SWITCHINGENGINEMAN-3-PPECELLDUPDETECTED: Free cell duplicate(s) 
detected [hex]. System will be reset!

Explanation    The system detected free cell duplication, and will be reset. This message may also erroneously appear when using jumbo packets or if sharing is configured and transmit queues have backed up.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHINGENGINEMAN-3-PPELEAKDETECTED: Hardware buffer leak 
detected. System will be reset!

Explanation    A PPE leak was detected, and the system will reset. This may be due to a transient hardware problem with the packet buffer related memories. This message may also erroneously appear if using jumbo packets or if sharing is configured and transmit queues have backed up.

Recommended Action    This is an informational message only. No action is required. To suppress the automatic reset action use the diagnostic monitor action conservative command.

Error Message    C4K_SWITCHINGENGINEMAN-7-PPELEAKMONITOR: Current Freelist count %u. 
Fell below threshold %u times consecutively

Explanation    The PPE freelist count is being monitored. Packet buffer leak detection is on and the freelist count is being monitored. This message displays the current count and number of times the count reached the threshold. If the freelist count stays below the threshold for more than one minute, the system will be reset.This message may also erroneously appear if using jumbo packets or if sharing is configured and transmit queues have backed up.

Recommended Action    This is an informational message only. No action is required. To suppress the automatic reset action use the diagnostic monitor action conservative command.

Error Message    C4K_SWITCHINGENGINEMAN-3-RDPMEOPMISMATCHERROR: RdPMEopMismatch error 
, subcell addr=[hex], reg bits=[hex], total errors=%u

Explanation    An error in a packet's cell was detected. This could indicate a problem with the packet cell linked list or subcell count memory. If this message persists, it may indicate a transient hardware problem, or a more permanent problem. After 1024 such End-Of-Packet mismatch errors, the switch will reload.

Recommended Action    After 1024 such End-Of-Packet mismatch errors, the switch will reload. If the switch is reloading too often due to this condition, you may need to check for environmental conditions such as RFI or other interference. It may also be necessary to replace the supervisor engine.

Error Message    C4K_SWITCHINGENGINEMAN-3-SUBCELLCNTMEMORYPARITYERROR: Parity error in 
subcell count memory, addr=[hex], reg bits=[hex], total errors=%u

Explanation    An error in subcell count memory was detected. If this message persists, it may indicate a transient hardware problem, or a more permanent problem. After 128 such subcell count errors, the switch will reload.

Recommended Action    If the switch is reloading too often due to this condition, you may need to check for environmental conditions such as RFI or other interference. It may also be necessary to replace the supervisor engine.

Error Message    C4K_SWITCHINGENGINEMAN-3-TXCNTMEMORYPARITYERROR: Parity error in 
transmit count memory, addr=[hex], reg bits=[hex], total errors=%u

Explanation    An error in transmit count memory was detected.If this message persists, it may indicate a transient hardware problem, or a more permanent problem. After 128 such transmit count errors, the switch will reload.

Recommended Action    If the switch is reloading too often due to this condition, you may need to check for environmental conditions such as RFI or other interference. It may also be necessary to replace the supervisor engine.

Error Message    C4K_SWITCHINGENGINEMAN-3-QUEUEMEMORYPARITYERROR:Parity error in Queue 
Memory, addr=[hex], total errors=%u 

Explanation    There is a parity error in the queue memory. This condition might indicate a transient hardware problem or a more permanent problem. After 128 packet memory and queue memory errors, the switch reloads.

Recommended Action    If this message reoccurs, reboot the switch.

Error Message    C4K_SWITCHINGENGINEMAN-3-TRANSMITQUEUESINIT:Tx Queues initialized 
multiple [dec] times

Explanation    The transmit queues had to be initialized multiple times.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHINGENGINEMAN-3-RXDELIMITERERROR: Invalid packet delimiter 
received. Expected [hex] Received [hex]

Explanation    Successive packets that are sent by the hardware to the CPU have a specific delimiter pattern. The software expected a delimiter pattern but received some other pattern. This condition might be caused by synchronization loss between the hardware and the software.

Recommended Action    Reboot the switch.

SWITCHINGENGINEMAN-4

Error Message    C4K_SWITCHINGENGINEMAN-4-PACKETMEMORYERROR: Error in Packet Memory 
[dec]

Explanation    An error in packet memory was detected. If this message persists, it might indicate a hardware problem.

Recommended Action    If this message persists, use the show diagnostics online command, contact your technical support representative, and provide the representative with the gathered information.

Error Message    C4K_SWITCHINGENGINEMAN-4-SYSTEMNOTRESET: System has already been reset  
[dec] times due to Packet Memory errors. System will  not be reset anymore

Explanation    The software detected a large number of errors in the packet memory and reset the switch. This condition indicates a hardware problem. However, the system only reset [dec] times by software to prevent an auto-boot followed by a reset loop.

Recommended Action    Replace the switch. If you do not replace the switch, errors may persist and the system will reset again.

SWITCHMANAGER Messages

This section contains the Switching Manager (SWITCHMANAGER) messages.

SWITCHMANAGER-3

Error Message    C4K_SWITCHMANAGER-3-DUPLICATESWPHYPORT: Internal Event: Tried to 
create new sw PimPhyport [char], but it already exists

Explanation    This message is a debug message that is used by developers only and should not occur during operation.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHMANAGER-3-DUPLICATESWPORT: Internal Event: Tried to create 
new sw PimPort [char], but it already exists

Explanation    This message is a debug message that is used by developers only and should not occur during operation.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHMANAGER-3-SSOACTIVEPORTACKTIMEOUT: Internal Event: timed 
out after [dec] iterations waiting for Standby to acknowledge port status change 
for [char]

Explanation    There is probably a software failure creating a communication problem between the active supervisor engine and the standby supervisor engine. SSO Redundancy mode cannot operate reliably when this condition occurs.

Recommended Action    Contact your technical support representative.

Error Message    C4K_SWITCHMANAGER-3-SSOHARDWAREACKTIMEOUT: Internal Event: timed out 
after [dec] iterations waiting for the [char] hardware to be programmed

Explanation    The active supervisor engine is taking more time than usual to program the hardware. This should not affect normal behavior or SSO functionality. In the worst case you may see link flaps when the supervisor engines switch over.

Recommended Action    This is an informational message only. No action is required. If the problem persists, contact your technical support representative.

SWITCHMANAGER-4

Error Message    C4K_SWITCHMANAGER-4-CANTPOWEROFF:Internal Error: PimEthAutoNegotiator 
- Can't power off port [char]

Explanation    This is an internal software error in an inline-power state machine.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHMANAGER-4-CANTPOWERON:Internal Error: PimEthAutoNegotiator 
- Can't power on port [char]

Explanation    This is an internal software error in an inline-power state machine.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHMANAGER-4-HARDWAREERROR:Power management hardware for port 
[char] bad.

Explanation    The switch cannot change the inline-power state for this port.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHMANAGER-4-S2WERROR:Power control to port [char] bad. 
Possibly power is turned on.

Explanation    This is a communication error in PoE power management.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWITCHMANAGER-4-S2WERRORREPORT: PimEthAutoNeg: S2w Read/Write 
Error for port [char].

Explanation    A read/write error occurred on the specified port.

Recommended Action    Refer to the release notes to verify whether you can see all the symptoms described for CSCef87815. If you do not and do not see any adverse effect on the functionality of the PoE linecards (WS-X4248-RJ45V, WS-X4248-RJ21V, WS-X4548-RJ45V, WS-X4224-RJ45V or WS-X4524-RJ45V), then treat this message an informational message only and no action is required.

Error Message    C4K_SWITCHMANAGER-4-SSOEANWARNPORTRESET: The state of the port [char] 
is unknown after switchover, resetting its link.

Explanation    A new switching module was inserted, and the active supervisor engine crashed unexpectedly before it could communicate the state of ports on the new module to the standby supervisor engine. The standby supervisor engine will assume that the port's link is down.

Recommended Action    This is an informational message only. No action is required.

SWITCHMANAGER-5

Error Message    C4K_SWITCHMANAGER-5-FLAPSHUTDOWN:Temporarily disabling port [char] 
due to flap

Explanation    The specified port is going up and down (link up/down) in rapid succession. This condition is usually caused by a bad connection or problems with the link-level hardware. The switch will temporarily shut down the problem port. Every 5 seconds, the switch reenables the port to see if the problem has gone away. If not, the port will remain shut down indefinitely.

Recommended Action    This is an informational message only. No action is required.

SWNETFLOWMAN Messages

This section contains the Software NetFlow Manager (SWNETFLOWMAN) messages.

SWNETFLOWMAN-4

Error Message    C4K_SWNETFLOWMAN-4-FLOWSTATISTICSLOST: Flow rate too high.  [dec] 
packet byte count statistics update lost  [object-info]

Explanation    The Cisco IOS flow uses 32-bit counters to store bytes per flow. The NetFlow Services Card engine uses 39-bit counters. When the switch reports a flow byte count that is greater than 32 bits, it stores the first 32 bits and logs a warning message.

Recommended Action    This is an informational message only. No action is required.

Error Message    C4K_SWNETFLOWMAN-4-NETFLOWCACHEFULL: Netflow hardware-software map 
cache full. Could not create a map.

Explanation    The switch uses a map to correlate flow in the software with corresponding flows in the hardware. This map is full and the switch cannot create any more mappings. This is a very rare condition. The switch is running at full capacity.

Recommended Action    This is an informational message only. No action is required.

SWNETFLOWMAN-6

Error Message    C4K_SWNETFLOWMAN-6-FIXEDCREATIONTIME:Fixed creation time of  [dec] 
flows.

Explanation    The system did not record the creation time of a flow. In this case, the system determined a creation time, which is usually the same time that was used for the last flow.

Recommended Action    If this message reoccurs frequently, and you see that the system is fixing a lot of flows, contact your technical support representative.

SYSMAN Messages

This section contains the System Manager (SYSMAN) messages.

SYSMAN-2

Error Message    C4K_SYSMAN-2-POWERONSELFTESTFAIL:Supervisor module in slot [dec] 
failed Power-On-Self-Test(POST). Line cards are **NOT** initialized. Please use 
'show diagnostics result module [dec]test <tid> detail' command for details.

Explanation    A power-on self test (POST) failure is detected on the supervisor engine. When this occurs, the modules are not initialized.

Recommended Action    Use the show diagnostics result module dec test tid detail command to isolate the problem. Reset the switch after you have resolved the supervisor engine failure.

SYSMAN-3

Error Message    C4K_SYSMAN-3-LINECARDDIAGSFAILED:Module in slot [dec] failed online 
diagnostics. Please use 'show diagnostics result module [dec]test <tid> detail' 
command for details.

Explanation    A module failed online diagnostics. When this occurs, all the module's ports are flagged as faulty and cannot be used until the problem is resolved.

Recommended Action    Remove and reinsert the module. If the problem persists, copy the message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    C4K_SYSMAN-3-LINECARDDIAGSPARTIALFAILURE:Partial failure on module 
[dec]. Please use 'show diagnostics result module [dec]test <tid> detail' command 
for details.

Explanation    Some of the module's ports have failed online diagnostics.

Recommended Action    Remove and reinsert the switch. If the problem persists, copy the message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

SYSMAN-4

Error Message    C4K_SYSMAN-4-MORETHANONEDEBUGCOMMANDEXECUTING:Cannot execute '[char]' 
right now, please try again later

Explanation    More than one Telnet session issued a debugging command at the same time. Only one Telnet session can issue a debugging command at the same time. All Telnet sessions receive this message, except the Telnet session that issued the command first.

Recommended Action    Try the command when other Telnet sessions are not issuing debugging commands.

TRANSCIEVER Messages

This section contains the TRANSCEIVER subsystem messages.

Error Message    TRANSCEIVER-3-INTERNAL_ERROR: [char]

Explanation    The TRANSCEIVER subsystem encountered an internal software error. The error message contains text that can be used to help identify the cause of the problem.

Recommended Action    Contact your technical support representative.

Error Message    TRANSCEIVER-3-LAYER_CHANGE_ERROR: Error changing layer for port [char]

Explanation    The TRANSCEIVER subsystem encountered an internal software error while changing the layer for this port.

Recommended Action    Contact your technical support representative.

UFAST_MCAST_SW Messages

This section contains the UplinkFast (UFAST_MCAST_SW) messages.

UFAST-3

Error Message    UFAST_MCAST_SW-3-PROC_START_ERROR:UplinkFast packets will not be 
transmitted as the process could not be created.

Explanation    The UplinkFast packets will not be transmitted as the process cannot be created.

Recommended Action    Reload UplinkFast. If this problem persists even after the reload, copy the message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

UFAST-4

Error Message    UFAST_MCAST_SW-4-MEM_NOT_AVAILABLE:No memory is available for 
transmitting UplinkFast packets on Vlan [dec].

Explanation    UplinkFast packets are not transmitted on VLAN [dec] due to a lack of memory.

Recommended Action    Reduce other system activity to ease memory demands. Contact your technical support representative to determine whether you need to upgrade to a larger memory configuration.

VQPCLIENT Messages

This section contains VLAN Query Protocol (VQP) Client messages.

VQPCLIENT-2

Error Message    VQPCLIENT-2-CHUNKFAIL: Could not allocate memory for VQP 

Explanation    An error occurred when the system tried to allocate memory for the VQP client.

Recommended Action    Copy the message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    VQPCLIENT-2-DENY: Host [enet] denied on interface [chars] 

Explanation    The VLAN Membership Policy Server (VMPS) denied access for the given host MAC address to an interface. [enet] is the host MAC address, and [chars] is the interface name.

Recommended Action    This is an informational message only. No action is required. If you think that the host should have been allowed access, verify the configuration on the VMPS.

Error Message    VQPCLIENT-2-INITFAIL: Platform-specific VQP initialization failed. 
Quitting 

Explanation    An error occurred during initialization of the VQP client platform-specific code.

Recommended Action    Copy the message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    VQPCLIENT-2-IPSOCK: Could not obtain IP socket 

Explanation    An error occurred when the system attempted to open an IP socket to the VMPS.

Recommended Action    If the error message recurs, copy the message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    VQPCLIENT-2-PROCFAIL: Could not create process for VQP. Quitting 

Explanation    An error occurred while creating a process for the VQP client.

Recommended Action    Copy the message exactly as it appears on the console or in the system log, contact your technical support representative, and provide the representative with the gathered information.

Error Message    VQPCLIENT-2-SHUTDOWN: Interface [chars] shutdown by VMPS 

Explanation    The VMPS directed that an interface be shut down. [chars] is the interface name.

Recommended Action    This is an informational message only. No action is required. If you think that the port should not have been shut down, then verify the configuration on the VMPS.

Error Message    VQPCLIENT-2-TOOMANY: Interface [chars] shutdown by active host limit 

Explanation    The system shut down an interface because too many hosts have requested access to that port. [chars] is the interface name.

Recommended Action    To reactivate the port, remove the excess hosts, and enter the no shutdown interface configuration command on the interface.

VQPCLIENT-3

Error Message    VQPCLIENT-3-IFNAME: Invalid interface ([char]) in response

Explanation    The VMPS sent an unsolicited response with an unknown interface name. [chars] is the name of the unknown interface.

Recommended Action    Verify the VMPS configuration.

Error Message    VQPCLIENT-3-THROTTLE: Throttling VLAN change on [chars] 

Explanation    An attempt was made to change the VLAN assignment for an interface more often than once every 10 seconds. The VLAN change is denied. [chars] is the name of the interface.

Recommended Action    This is an informational message only. No action is required. If this message reoccurs, verify the VMPS configuration and that unexpected hosts are not connected to the port.

Error Message    VQPCLIENT-3-VLANNAME: Invalid VLAN ([chars]) in response 

Explanation    VMPS specified a VLAN name that is unknown to the switch. [chars] is the invalid VLAN name.

Recommended Action    Make sure that the VLAN exists on the switch. Verify the VMPS configuration.

VQPCLIENT-7

Error Message    VQPCLIENT-7-NEXTSERV: Trying next VMPS 

Explanation    The system lost connectivity with the current VMPS and is changing to the next server in its list.

Recommended Action    This is an informational message only. No action is required.

Error Message    VQPCLIENT-7-PROBE: Probing primary server [IP_address] 

Explanation    The system is trying to reestablish connectivity with the primary VMPS at the given IP address.

Recommended Action    This is an informational message only. No action is required.

Error Message    VQPCLIENT-7-RECONF: Reconfirming VMPS responses 

Explanation    The switch is reconfirming all responses with the VMPS.

Recommended Action    This is an informational message only. No action is required.

WATCHDOG Messages

This section contains the watchdog (WATCHDOG) message.

Error Message    C4K_WATCHDOG-3-CHILDFAILURE:Watchdog failure ([char]) - system may 
reset

Explanation    The job [char] was unscheduled and not started soon enough to start its watchdog timer.

Recommended Action    Determine what other activity is utilizing the supervisor engine.