Configuring Interfaces


This chapter describes how to configure interfaces for the Catalyst 4500 series switches. It also provides guidelines, procedures, and configuration examples.

This chapter includes the following major sections:

Overview of Interface Configuration

Using the interface Command

Configuring a Range of Interfaces

Defining and Using Interface-Range Macros

Deploying 10-Gigabit Ethernet and a Gigabit Ethernet SFP Ports

Digital Optical Monitoring Transceiver Support

Configuring Optional Interface Features

Understanding Online Insertion and Removal

Monitoring and Maintaining the Interface


Note For complete syntax and usage information for the switch commands used in this chapter, refer to the Catalyst 4500 Series Switch Cisco IOS Command Reference and related publications at this location:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios124/124cr/index.htm.


Overview of Interface Configuration

By default, all interfaces are enabled. The 10/100-Mbps Ethernet interfaces autonegotiate connection speed and duplex. The 10/100/1000-Mbps Ethernet interfaces negotiate speed, duplex, and flow control. The 1000-Mbps Ethernet interfaces negotiate flow control only. Autonegotiation automatically selects the fastest speed possible on that port for the given pair. If a speed is explicitly stated for an interface, that interface will default to half duplex unless it is explicitly set for full duplex.

Many features are enabled on a per-interface basis. When you enter the interface command, you must specify the following:

Interface type:

Fast Ethernet (use the fastethernet keyword)

Gigabit Ethernet (use the gigabitethernet keyword)

10-Gigabit Ethernet (use the tengigabitethernet keyword)

Slot number—The slot in which the interface module is installed. Slots are numbered starting with 1, from top to bottom.

Interface numberThe interface number on the module. The interface numbers always begin with 1. When you are facing the front of the switch, the interfaces are numbered from left to right.

You can identify interfaces by physically checking the slot/interface location on the switch. You can also use the Cisco IOS show commands to display information about a specific interface or all the interfaces.

Using the interface Command

These general instructions apply to all interface configuration processes:


Step 1 At the privileged EXEC prompt, enter the configure terminal command to enter global configuration mode:

Switch# configure terminal 
Enter configuration commands, one per line.  End with CNTL/Z.
Switch(config)# 

Step 2 In global configuration mode, enter the interface command. Identify the interface type and the number of the connector on the interface card. The following example shows how to select Fast Ethernet, slot 5, interface 1:

Switch(config)# interface fastethernet 5/1 
Switch(config-if)# 

Step 3 Interface numbers are assigned at the factory at the time of installation or when modules are added to a system. Enter the show interfaces EXEC command to see a list of all interfaces installed on your switch. A report is provided for each interface that your switch supports, as shown in this display:

Switch(config-if)#Ctrl-Z
Switch#show interfaces
Vlan1 is up, line protocol is down 
  Hardware is Ethernet SVI, address is 0004.dd46.7aff (bia 0004.dd46.7aff)
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, 
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input never, output never, output hang never
  Last clearing of "show interface" counters never
  Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     0 packets input, 0 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 interface resets
     0 output buffer failures, 0 output buffers swapped out
GigabitEthernet1/1 is up, line protocol is down 
  Hardware is Gigabit Ethernet Port, address is 0004.dd46.7700 (bia 0004.dd46.7700)
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, 
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Auto-duplex, Auto-speed
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input never, output never, output hang never
  Last clearing of "show interface" counters never
  Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     0 packets input, 0 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 input packets with dribble condition detected
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out
GigabitEthernet1/2 is up, line protocol is down 
  Hardware is Gigabit Ethernet Port, address is 0004.dd46.7701 (bia 0004.dd46.7701)
  MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec, 
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Auto-duplex, Auto-speed
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input never, output never, output hang never
  Last clearing of "show interface" counters never
  Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     0 packets input, 0 bytes, 0 no buffer
     Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 input packets with dribble condition detected
     0 packets output, 0 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     0 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out
--More-- 
<...output truncated...>

Step 4 To begin configuring Fast Ethernet interface 5/5, as shown in the following example, enter the interface keyword, interface type, slot number, and interface number in global configuration mode:

Switch# configure terminal 
Enter configuration commands, one per line.  End with CNTL/Z.
Switch(config)# interface fastethernet 5/5 
Switch(config-if)# 


Note You do not need to add a space between the interface type and interface number. For example, in the preceding line you can specify either fastethernet 5/5 or fastethernet5/5.


Step 5 Follow each interface command with the interface configuration commands your particular interface requires. The commands you enter define the protocols and applications that will run on the interface. The commands are collected and applied to the interface command until you enter another interface command or press Ctrl-Z to exit interface configuration mode and return to privileged EXEC mode.

Step 6 After you configure an interface, check its status by using the EXEC show commands listed in "Monitoring and Maintaining the Interface" section.


Configuring a Range of Interfaces

The interface-range configuration mode allows you to configure multiple interfaces with the same configuration parameters. When you enter the interface-range configuration mode, all command parameters you enter are attributed to all interfaces within that range until you exit interface-range configuration mode.

To configure a range of interfaces with the same configuration, perform this task:

Command
Purpose
Switch(config)# interface range 
{vlan vlan_ID - vlan_ID} | 
{{fastethernet | gigabitethernet | 
tengigabitethernet | macro macro_name} 
slot/interface - interface} [, 
{vlan vlan_ID - vlan_ID} {{fastethernet 
| gigabitethernet | tengigabitethernet | 
macro macro_name} 
slot/interface - interface}] 

Selects the range of interfaces to be configured. Note the following:

You are required to enter a space before the dash.

You can enter up to five comma-separated ranges.

You are not required to enter spaces before or after the comma.



Note When you use the interface range command, you must add a space between the vlan, fastethernet, gigabitethernet, tengigabitethernet, or macro keyword and the dash. For example, the command interface range fastethernet 5/1 - 5 specifies a valid range; the command
interface range fastethernet 1-5 does not contain a valid range command.



Note The interface range command works only with VLAN interfaces that have been configured with the interface vlan command (the show running-configuration command displays the configured VLAN interfaces). VLAN interfaces that are not displayed by the show running-configuration command cannot be used with the interface range command.


This example shows how to reenable all Fast Ethernet interfaces 5/1 to 5/5:

Switch(config)# interface range fastethernet 5/1 - 5 
Switch(config-if-range)# no shutdown 
Switch(config-if-range)#
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet5/1, changed state to up
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet5/2, changed state to up
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet5/3, changed state to up
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet5/4, changed state to up
*Oct  6 08:24:35: %LINK-3-UPDOWN: Interface FastEthernet5/5, changed state to up
*Oct  6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet5/
5, changed state to up
*Oct  6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet5/
3, changed state to up
*Oct  6 08:24:36: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet5/
4, changed state to up
Switch(config-if)#

This example shows how to use a comma to add different interface type strings to the range to reenable all Fast Ethernet interfaces in the range 5/1 to 5/5 and both Gigabit Ethernet interfaces 1/1 and 1/2:

Switch(config-if)# interface range fastethernet 5/1 - 5, gigabitethernet 1/1 - 2 
Switch(config-if)# no shutdown 
Switch(config-if)#
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface FastEthernet5/1, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface FastEthernet5/2, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface FastEthernet5/3, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface FastEthernet5/4, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface FastEthernet5/5, changed state to up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet1/1, changed state to
 up
*Oct  6 08:29:28: %LINK-3-UPDOWN: Interface GigabitEthernet1/2, changed state to
 up
*Oct  6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet5/
5, changed state to up
*Oct  6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet5/
3, changed state to up
*Oct  6 08:29:29: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet5/
4, changed state to up
Switch(config-if)#

If you enter multiple configuration commands while you are in interface-range configuration mode, each command is run as it is entered (they are not batched together and run after you exit interface-range configuration mode). If you exit interface-range configuration mode while the commands are being run, some commands might not be run on all interfaces in the range. Wait until the command prompt is displayed before exiting interface-range configuration mode.

Defining and Using Interface-Range Macros

You can define an interface-range macro to automatically select a range of interfaces for configuration. Before you can use the macro keyword in the interface-range macro command string, you must define the macro.

To define an interface-range macro, perform this task:

Command
Purpose
Switch(config)# define interface-range macro_name 
{vlan vlan_ID - vlan_ID} | {{fastethernet | 
gigabitethernet} slot/interface interface} 
[, {vlan vlan_ID - vlan_ID} {{fastethernet | 
gigabitethernet} slot/interface - interface}] 

Defines the interface-range macro and saves it in the running configuration file.


This example shows how to define an interface-range macro named enet_list to select Fast Ethernet interfaces 5/1 through 5/4:

Switch(config)# define interface-range enet_list fastethernet 5/1 - 4 

To show the defined interface-range macro configuration, perform this task:

Command
Purpose
Switch# show running-config 

Shows the defined interface-range macro configuration.


This example shows how to display the defined interface-range macro named enet_list:

Switch# show running-config | include define 
define interface-range enet_list FastEthernet5/1 - 4
Switch#

To use an interface-range macro in the interface range command, perform this task:

Command
Purpose
Switch(config)# interface range macro 
name 

Selects the interface range to be configured using the values saved in a named interface-range macro.


This example shows how to change to the interface-range configuration mode using the interface-range macro enet_list:

Switch(config)# interface range macro enet_list 
Switch(config-if)#

Deploying 10-Gigabit Ethernet and a Gigabit Ethernet SFP Ports


Note On a Catalyst 4510R series switch, if you enable both the 10-Gigabit Ethernet and Gigabit Ethernet SFP uplink ports, you must re-boot the switch. On the Catalyst 4503, 4506, and 4507R series switches, this capability is automatically enabled.


Prior to Cisco Release 12.2(25)SG, the Cisco Catalyst 4500 Supervisor Engine V-10GE allowed you to enable either the dual wire-speed 10-Gigabit Ethernet ports, or four alternatively wired Gigabit Ethernet SFP uplink ports. With Cisco Release 12.2(25)SG, you can simultaneously deploy the dual 10 Gigabit Ethernet ports and the four Gigabit Ethernet SFP ports. This capability is supported on the Catalyst 4503, Catalyst 4506, and Catalyst 4507R chassis.

When deploying a Catalyst 4510R chassis, one of three configurations is supported:

Enable the dual 10 -Gigabit Ethernet ports (X2 optics) only.

Enable the four Gigabit Ethernet ports (SFP optics) only.

Enable both the dual 10 Gigabit Ethernet and the four Gigabit Ethernet ports, with the understanding that the tenth slot (Flex-Slot) will only support a 2-port gigabit interface converter (GBIC) line card (WS-X4302-GB) when in this mode.

To select the 10-Gigabit Ethernet and/or the Gigabit Ethernet SFP uplink ports, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal

Establishes global configuration mode.

Step 2 

Switch(config)# hw-module uplink select [all | 
gigabitethernet | tengigabitethernet]

Selects the port type to enable.

The following example shows how to enable both 10-Gigabit Ethernet and Gigabit Ethernet SFP uplink ports on a Catalyst 4510R series switch:

Switch# configure terminal
Switch(config)# hw-module uplink select all
Warning: This configuration mode will place slot 10 in flex slot mode

Digital Optical Monitoring Transceiver Support

Command line interface (CLI) commands (show inventory, show idprom interface) are used on transceivers to obtain serail number, model name, inventory information.

The following commands are specific to the transceivers that support the DOM capability:

Display current values and thresholds for all sensor on a particular interface transceiver:

show interfaces <int-name> transceiver [detail] [threshold]

Enable/Disable the entSensorThresholdNotification for all sensors in all the transceivers:

snmp-server enable trap transceiver

Enable/Disable transceiver monitoring:

transceiver type all


Note This feature is only available when a DOM capable transceiver is present and configured for monitoring. The frequency at which the sensor information is refreshed depends on default values configured in the transceiver SEEPROM (Serial Electrically Erasable Programmable Read Only Memory).


Configuring Optional Interface Features

The following subsections describe optional procedures:

Configuring Ethernet Interface Speed and Duplex Mode

Configuring Flow Control

Configuring Jumbo Frame Support

Interacting with the Baby Giants Feature

Configuring Auto-MDIX on a Port

Configuring Ethernet Interface Speed and Duplex Mode

Speed and Duplex Mode Configuration Guidelines

Setting the Interface Speed

Setting the Interface Duplex Mode

Displaying the Interface Speed and Duplex Mode Configuration

Adding a Description for an Interface

Speed and Duplex Mode Configuration Guidelines


Note You do not configure the client device for autonegotiation. Rather, you configure the switch with the speed, or range of speeds, that you want to autonegotiate.


You can configure the interface speed and duplex mode parameters to auto and allow the Catalyst 4500 series switch to negotiate the interface speed and duplex mode between interfaces. If you decide to configure the interface speed and duplex commands manually, consider the following:

If you enter the no speed command, the switch automatically configures both interface speed and duplex to auto.

When you set the interface speed to 1000 (Mbps) or auto 1000, the duplex mode is full duplex. You cannot change the duplex mode.

If the interface speed is set to 10 or 100, the duplex mode is set to half duplex by default unless you explicitly configure it.


Caution Changing the interface speed and duplex mode configuration might shut down and restart the interface during the reconfiguration.

Setting the Interface Speed

If you set the interface speed to auto on a 10/100-Mbps Ethernet interface, speed and duplex are autonegotiated. The forced 10/100 autonegotiation feature allows you to limit interface speed auto negotiation up to 100 Mbps on a 10/100/1000BASE-T port.

To set the port speed for a 10/100-Mbps Ethernet interface, perform this task:

 
Command
Purpose

Step 1 

Switch(config)# interface fastethernet slot/interface

Specifies the interface to be configured.

Step 2 

Switch(config-if)# speed [10 | 100 | auto [10 | 100]] 

Sets the interface speed of the interface.

This example shows how to set the interface speed to 100 Mbps on the Fast Ethernet interface 5/4:

Switch(config)# interface fastethernet 5/4
Switch(config-if)# speed 100

This example shows how to allow Fast Ethernet interface 5/4 to autonegotiate the speed and duplex mode:

Switch(config)# interface fastethernet 5/4
Switch(config-if)# speed auto

Note This is analogous to specifying speed auto 10 100.


This example shows how to limit the interface speed to 10 and 100 Mbps on the Gigabit Ethernet interface 1/1 in auto-negotiation mode:

Switch(config)# interface gigabitethernet 1/1
Switch(config-if)# speed auto 10 100

This example shows how to limit speed negotiation to 100 Mbps on the Gigabit Ethernet interface 1/1:

Switch(config)# interface gigabitethernet 1/1
Switch(config-if)# speed auto 100

Note Turning off autonegotiation on a Gigabit Ethernet interface will result in the port being forced into 1000 Mbps and full-duplex mode.


To turn off the port speed autonegotiation for Gigabit Ethernet interface 1/1, perform this task:

 
Command
Purpose

Step 1 

Switch(config)# interface gigabitethernet1/1 

Specifies the interface to be configured.

Step 2 

Switch(config-if)# speed nonegotiate 

Disables autonegotiation on the interface.

To restore autonegotiation, enter the no speed nonegotiate command in the interface configuration mode.


Note For the blocking ports on the WS-X4416 module, do not set the speed to autonegotiate.


Setting the Interface Duplex Mode


Note When the interface is set to 1000 Mbps, you cannot change the duplex mode from full duplex to half duplex.


To set the duplex mode of a Fast Ethernet interface, perform this task:

 
Command
Purpose

Step 1 

Switch(config)# interface fastethernet 
slot/interface 

Specifies the interface to be configured.

Step 2 

Switch(config-if)# duplex [auto | full | half] 

Sets the duplex mode of the interface.

This example shows how to set the interface duplex mode to full on Fast Ethernet interface 5/4:

Switch(config)# interface fastethernet 5/4
Switch(config-if)# duplex full

Displaying the Interface Speed and Duplex Mode Configuration

To display the interface speed and duplex mode configuration for an interface, perform this task:

Command
Purpose
Switch# show interfaces [fastethernet | 
gigabitethernet | tengigabitethernet] 
slot/interface 

Displays the interface speed and duplex mode configuration.


This example shows how to display the interface speed and duplex mode of Fast Ethernet interface 6/1:

Switch# show interface fastethernet 6/1
FastEthernet6/1 is up, line protocol is up 
  Hardware is Fast Ethernet Port, address is 0050.547a.dee0 (bia 0050.547a.dee0)
  MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec, 
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Full-duplex, 100Mb/s
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:54, output never, output hang never
  Last clearing of "show interface" counters never
  Input queue: 50/2000/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     50 packets input, 11300 bytes, 0 no buffer
     Received 50 broadcasts, 0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 input packets with dribble condition detected
     1456 packets output, 111609 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     1 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out
Switch#

Adding a Description for an Interface

You can add a description about an interface to help you remember its function. The description appears in the output of the following commands: show configuration, show running-config, and
show interfaces.

To add a description for an interface, enter the following command:

Command
Purpose
Switch(config-if)# description string 

Adds a description for an interface.


This example shows how to add a description on Fast Ethernet interface 5/5:

Switch(config)# interface fastethernet 5/5 
Switch(config-if)# description Channel-group to "Marketing" 

Configuring Flow Control

Gigabit Ethernet ports use Flow Control to slow-down the transmission of incoming packets. If a buffer on a Gigabit Ethernet port runs out of space, the port transmits a special packet that requests remote ports to delay sending packets for a period of time. The port can also receive this special packet from its link-partner for the same purpose. This special packet is called a pause frame.

The default settings for Gigabit Ethernet interfaces are as follows:

Sending pause frames is off—non-oversubscribed Gigabit Ethernet interfaces.

Receiving pause frames is desired—non-oversubscribed Gigabit Ethernet interfaces.

Sending pause frames is on—Oversubscribed Gigabit Ethernet interfaces.

Receiving pause frames is desired—Oversubscribed Gigabit Ethernet interfaces

The default settings for Tengigabit Ethernet interfaces are as follows:

Sending pause frames is off.

Receiving pause frames is on.


Note desired is not a flow control option on these links


To configure flow control, perform this task:

 
Command
Purpose

Step 1 

Switch# configure terminal

Enters global configuration mode.

Step 2 

Switch(config)# interface 
interface-id

Enters interface configuration mode and specifies the interface to be enabled for flowcontrol.

Step 3 

Switch(config-if)# flowcontrol 
{receive | send} {off | on | 
desired}

Configures a Gigabit Ethernet port to send or receive pause frames.

Step 4 

Switch(config-if)# end

Returns to configuration mode.

Step 5 

Switch(config)# end

Returns to privileged EXEC mode.

This example shows how to configure flow control on an oversubscribed Gigabit Ethernet port 7/5:

Switch# configure terminal
Switch(config)# interface g7/5
Switch(config-if)# flowcontrol send on
Switch(config-if)# end
Switch)# show inmterfaces gigabitEthernet 7/5 capabilities
GigabitEthernet7/5
  Model:                 WS-X4548-GB-RJ45-RJ-45
  Type:                  10/100/1000-TX
  Speed:                 10,100,1000,auto
  Duplex:                half,full,auto
  Trunk encap. type:     802.1Q,ISL
  Trunk mode:            on,off,desirable,nonegotiate
  Channel:               yes
  Broadcast suppression: percentage(0-100), hw
  Flowcontrol:           rx-(off,on,desired),tx-(off,on,desired)
  VLAN Membership:       static, dynamic
  Fast Start:            yes
  Queuing:               rx-(N/A), tx-(1p3q1t, Sharing/Shaping)
  CoS rewrite:           yes
  ToS rewrite:           yes
  Inline power:          no
  SPAN:                  source/destination
  UDLD:                  yes
  Link Debounce:         no
  Link Debounce Time:    no
  Port Security:         yes
  Dot1x:                 yes
  Maximum MTU:           1552 bytes (Baby Giants)
  Multiple Media Types:  no
  Diagnostic Monitoring: N/A

Switch)# show flowcontrol interface GigabitEthernet 7/5
Port       Send FlowControl  Receive FlowControl  RxPause TxPause
           admin    oper     admin    oper
---------  -------- -------- -------- --------    ------- -------
Gi7/5      on       off      desired  off         0       0

This example shows the output of the show interfaces and show flowcontrol commands on an non-overscribed Gigabit Ethernet port 5/5:

Switch# show interfaces gigabitEthernet 5/5 capabilities
GigabitEthernet5/5
  Model:                 WS-X4306-GB-Gbic
  Type:                  No Gbic
  Speed:                 1000
  Duplex:                full
  Trunk encap. type:     802.1Q,ISL
  Trunk mode:            on,off,desirable,nonegotiate
  Channel:               yes
  Broadcast suppression: percentage(0-100), hw
  Flowcontrol:           rx-(off,on,desired),tx-(off,on,desired)
  VLAN Membership:       static, dynamic
  Fast Start:            yes
  Queuing:               rx-(N/A), tx-(1p3q1t, Sharing/Shaping)
  CoS rewrite:           yes
  ToS rewrite:           yes
  Inline power:          no
  SPAN:                  source/destination
  UDLD:                  yes
  Link Debounce:         no
  Link Debounce Time:    no
  Port Security:         yes
  Dot1x:                 yes
  Maximum MTU:           9198 bytes (Jumbo Frames)
  Multiple Media Types:  no
  Diagnostic Monitoring: N/A

Switch# show flowcontrol interface gigabitEthernet 5/5
Port       Send FlowControl  Receive FlowControl  RxPause TxPause
           admin    oper     admin    oper
---------  -------- -------- -------- --------    ------- -------
Gi5/5      off      off      desired  off         0       0

This example shows the output of the show interfaces and show flowcontrol commands on an unsupported Fast Ethernet port 3/5:

Switch# show interfaces fa3/5 capabilities
FastEthernet3/5
  Model:                 WS-X4148-RJ-45
  Type:                  10/100BaseTX
  Speed:                 10,100,auto
  Duplex:                half,full,auto
  Trunk encap. type:     802.1Q,ISL
  Trunk mode:            on,off,desirable,nonegotiate
  Channel:               yes
  Broadcast suppression: percentage(0-100), sw
  Flowcontrol:           rx-(none),tx-(none)
  VLAN Membership:       static, dynamic
  Fast Start:            yes
  Queuing:               rx-(N/A), tx-(1p3q1t, Shaping)
  CoS rewrite:           yes
  ToS rewrite:           yes
  Inline power:          no
  SPAN:                  source/destination
  UDLD:                  yes
  Link Debounce:         no
  Link Debounce Time:    no
  Port Security:         yes
  Dot1x:                 yes
  Maximum MTU:           1552 bytes (Baby Giants)
  Multiple Media Types:  no
  Diagnostic Monitoring: N/A

Switch# show flowcontrol interface fa3/5
Port       Send FlowControl  Receive FlowControl  RxPause TxPause
           admin    oper     admin    oper
---------  -------- -------- -------- --------    ------- -------
Fa3/5      Unsupp.  Unsupp.  Unsupp.  Unsupp.      0       0

Configuring Jumbo Frame Support

These subsections describe jumbo frame support:

Ports and Modules that Support Jumbo Frames

Understanding Jumbo Frame Support

Configuring MTU Sizes

Ports and Modules that Support Jumbo Frames

The following ports and modules support jumbo frames:

Supervisor uplink ports

WS-X4306-GB: all ports

WS-X4232-GB-RJ: ports 1-2

WS-X4418-GB: ports 1-2

WS-X4412-2GB-TX: ports 13-14

Each of the last three modules has two non-blocking ports that can support jumbo frames. Other ports are over-subscribed ports and cannot support jumbo frames.

Understanding Jumbo Frame Support

These sections describe jumbo frame support:

Jumbo Frame Support Overview

Ethernet Ports

VLAN Interfaces

Jumbo Frame Support Overview

A jumbo frame is a frame larger than the default Ethernet size. Enable jumbo frame support by configuring a larger-than-default maximum transmission unit (MTU) size on a port or interface.

Catalyst 4500 series switch Ethernet LAN ports configured with a nondefault MTU size accept frames containing packets with a size between 1500 and 9198 bytes. With a nondefault MTU size configured, the packet size of ingress frames is checked. If the packet is larger than the configured MTU, it is dropped.

For traffic that needs to be routed, the MTU of the egress port is checked. If the MTU is smaller than the packet size, the packet is forwarded to the CPU. If the "do not fragment bit" is not set, it is fragmented. Otherwise, the packet is dropped.


Note Jumbo frame support does not fragment Layer 2 switched packets.


The Catalyst 4500 series switch does not compare the packet size with the MTU at the egress port, but jumbo frames are dropped in ports that do not support them. The frames can be transmitted in ports that do support jumbo frames, even though the MTU is not configured to jumbo size.


Note Jumbo frame support is only configured per interface; jumbo frame support cannot be configured globally.


Ethernet Ports

These sections describe configuring nondefault MTU sizes on Ethernet ports:

Ethernet Port Overview

Layer 3 and Layer 2 EtherChannels

Ethernet Port Overview

With Cisco IOS Release 12.2(25)EW, configuring a nondefault MTU size on certain Ethernet ports limits the size of ingress packets. The MTU does not impact the egress packets.

With releases earlier than Cisco IOS Release 12.1(13)EW, you can configure the MTU size only on Gigabit Ethernet.

Layer 3 and Layer 2 EtherChannels

With Release Cisco IOS Release 12.2(25)EW and later releases, you can configure all the interfaces in an EtherChannel provided that they have the same MTU. Changing the MTU of an EtherChannel changes the MTU of all member ports. If the MTU of a member port cannot be changed to the new value, that port is suspended (administratively shut down). A port cannot join an EtherChannel if the port has a different MTU. If a member port of an EtherChannel changes MTU, the member port is suspended.

VLAN Interfaces

If switch ports reside in the same VLAN, either configure all of the switch ports to handle jumbo frames and support the same MTU size, or configure none of them. However, such uniformity of MTU size in the same VLAN is not enforced.

When a VLAN has switch ports with different MTU size, packets received from a port with a larger MTU might be dropped when they are forwarded to a port with a smaller MTU.

If the switch ports in a VLAN have jumbo frames enabled, the corresponding SVI can have jumbo frames enabled. The MTU of an SVI should always be smaller than the smallest MTU among all the switch ports in the VLAN, but this condition is not enforced.

The MTU of a packet is not checked on the ingress side for an SVI; it is checked on the egress side of an SVI. If the MTU of a packet is larger than the MTU of the egress SVI, the packet will be sent to the CPU for fragmentation processing. If the "do not fragment" bit is not set, the packet is fragmented. Otherwise, the packet is dropped.

Configuring MTU Sizes

To configure the MTU size, perform this task:

 
Command
Purpose

Step 1 

Switch(config)# interface {{vlan vlan_ID} | 
{{type1  slot/port} | {port-channel 
port_channel_number} slot/port}} 

Selects the interface to configure.

Step 2 

Switch(config-if)# mtu mtu_size

Configures the MTU size.

Switch(config-if)# no mtu 

Reverts to the default MTU size (1500 bytes).

Step 3 

Switch(config-if)# end 

Exits configuration mode.

Step 4 

Switch# show running-config interface 
[{fastethernet | gigabitethernet} slot/port] 

Displays the running configuration.

1 type = fastethernet, gigabitethernet, or tengigabitethernet


Note When configuring the MTU size for VLAN interfaces and Layer 3 and Layer 2 Ethernet ports, note that the supported MTU values are from 1500 to 9198 bytes.


This example shows how to configure the MTU size on Gigabit Ethernet port 1/1:

switch# conf t
switch(config)# int gi1/1
switch(config-if)# mtu 9198
switch(config-if)# end

This example shows how to verify the configuration:

switch# show interface gigabitethernet 1/2
GigabitEthernet1/2 is administratively down, line protocol is down
  Hardware is C6k 1000Mb 802.3, address is 0030.9629.9f88 (bia 0030.9629.9f88)
  MTU 9216 bytes, BW 1000000 Kbit, DLY 10 usec,
<...Output Truncated...>
switch#

Interacting with the Baby Giants Feature

The baby giants feature, introduced in Cisco IOS Release 12.1(12c)EW, uses the global command system mtu <size> to set the global baby giant MTU. This feature also allows certain interfaces to support Ethernet payload size of up to 1552 bytes.

Both the system mtu command and the per-interface mtu command can operate on interfaces that can support jumbo frames, but the per-interface mtu command takes precedence.

For example, before setting the per-interface MTU for interface gi1/1, you issue the
system mtu 1550 command to change the MTU for gi1/1 to 1550 bytes. Next, you issue the per-interface mtu command to change the MTU for gi1/1 to 9198 bytes. Now, if you change the baby giant MTU to 1540 bytes with the command system mtu 1540, the MTU for gi1/1 remains unchanged at 9198 bytes.

Configuring Auto-MDIX on a Port

When automatic medium-dependent-interface crossover (auto-MDIX) is enabled on an port, the port automatically detects the required cable connection type (straight through or crossover) and configures the connection appropriately. When connecting switches without the auto-MDIX feature, you must use straight-through cables to connect to devices such as servers, workstations, or routers and crossover cables to connect to other switches or repeaters. With auto-MDIX enabled, you can use either type of cable to connect to other devices, and the interface automatically corrects for any incorrect cabling. For more information about cabling requirements, see the hardware installation guide.

Auto-MDIX is enabled by default. When you enable auto-MDIX, you must also set the speed on the port to auto so that for the feature to operate correctly. auto-MDIX is supported on copper media ports. It is not supported on fiber media ports.


Note The following linecards support Auto-MDIX by default, when port auto-negotiation is enabled: WS-X4448-GB-RJ45 and WS-X4548-GB-RJ45. You cannot disable them with the the mdix command.



Note The following linecards do not support Auto-MDIX, neither by default nor by CLI: WS-X4548-GB-RJ45V, WS-X4524-GB-RJ45V, and WS-X4506-GB-T.



Note The following linecards support Auto-MDIX through the CLI on their copper media ports: WS-X4124-RJ45, WS-X4148-RJ45 (hardware revision 3.0 or higher), and WS-X4232-GB-RJ45 (hardware revision 3.0 or higher).


Table 6-1 shows the link states that results from auto-MDIX settings and correct and incorrect cabling.

Table 6-1 Link Conditions and auto-MDIX Settings 

Local Side auto-MDIX
Remote Side auto-MDIX
With Correct Cabling
With Incorrect Cabling

On

On

Link up

Link up

On

Off

Link up

Link up

Off

On

Link up

Link up

Off

Off

Link up

Link down


To configure auto-MDIX on a port, perform the following task:

 
Command
Purpose

Step 1 

configure terminal

Enters global configuration mode

Step 2 

interface interface-id

Enters interface configuration mode for the physical interface to be configured.

Step 3 

speed auto

Configures the port to autonegotiate speed with the connected device.

Step 4 

mdix auto

Enables auto-MDIX on the port.

Step 5 

end

Returns to privileged EXEC mode.

Step 6 

show interfaces interface-id

Verifies the configuration of the auto-MDIX feature on the interface.

Step 7 

copy running-config startup-config

(Optional) Saves your entries in the configuration file.

To disable auto-MDIX, use the no mdix auto interface configuration command.

This example shows how to enable auto-MDIX on a port:

Switch# configure terminal
Switch(config)# interface fastethernet 6/5
Switch(config-if)# speed auto
Switch(config-if)# mdix auto
Switch(config-if)# end

Displaying the Interface auto-MDIX Configuration

To display the interface speed and duplex mode configuration for an interface, perform this task:

 
Command or Action
Purpose

Step 1 

Switch> enable

Enables privileged EXEC mode.

Enter your password if prompted.

Step 2 

Switch# show interfaces type slot/interface

Displays the interface auto-MDIX configuration setting and operational state.

Depending on how the speed auto and the mdix auto commands are configured on a supported linecard interface, the show interfaces command displays the following possible auto-MDIX statuses:

Table 6-2 shows the auto-MDIX setting and operational state and the status of auto-MDIX.

Table 6-2 Auto-MDIX and Operational State

Auto-MDIX Setting And Operational State
on an Interface
Description

Auto-MDIX on (operational: on)

Auto-MDIX is enabled and is fully functioning.

Auto-MDIX on (operational: off)

Auto-MDIX is enabled on this interface but it is not functioning. To allow auto-MDIX feature to function properly, you must also set the interface speed to be autonegotiated.

Auto-MDIX off

Auto-MDIX has been disabled with the
no mdix auto command.


This example show s how to display the auto-MDIX configuration setting and its operational state on Fast Ethernet interface 6/1:

Switch# show interfaces fastethernet 6/1
FastEthernet6/1 is up, line protocol is up (connected)
  Hardware is Fast Ethernet Port, address is 0001.64fe.e5d0 (bia 0001.64fe.e5d0)
  MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec,
     reliability 255/255, txload 1/255, rxload 1/255
  Encapsulation ARPA, loopback not set
  Keepalive set (10 sec)
  Full-duplex, 100Mb/s, link type is auto, media type is 10/100BaseTX
  input flow-control is unsupported output flow-control is unsupported
  Auto-MDIX on (operational: on)
  ARP type: ARPA, ARP Timeout 04:00:00
  Last input 00:00:16, output never, output hang never
  Last clearing of "show interface" counters never
  Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
  Queueing strategy: fifo
  Output queue: 0/40 (size/max)
  5 minute input rate 0 bits/sec, 0 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     511 packets input, 74464 bytes, 0 no buffer
     Received 511 broadcasts (511 multicasts)
     0 runts, 0 giants, 0 throttles
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
     0 input packets with dribble condition detected
     3552 packets output, 269088 bytes, 0 underruns
     0 output errors, 0 collisions, 0 interface resets
     0 babbles, 0 late collision, 0 deferred
     1 lost carrier, 0 no carrier
     0 output buffer failures, 0 output buffers swapped out
Switch#

Understanding Online Insertion and Removal

The online insertion and removal (OIR) feature supported on the Catalyst 4500 series switch allows you to remove and replace modules while the system is online. You can shut down the module before removal and restart it after insertion without causing other software or interfaces to shut down.

You do not need to enter a command to notify the software that you are going to remove or install a module. The system notifies the supervisor engine that a module has been removed or installed and scans the system for a configuration change. The newly installed module is initialized, and each interface type is verified against the system configuration; then the system runs diagnostics on the new interface. There is no disruption to normal operation during module insertion or removal.

If you remove a module and then replace it, or insert a different module of the same type into the same slot, no change to the system configuration is needed. An interface of a type that has been configured previously will be brought online immediately. If you remove a module and insert a module of a different type, the interface(s) on that module will be administratively up with the default configuration for that module.

Monitoring and Maintaining the Interface

The following sections describe how to monitor and maintain the interfaces:

Monitoring Interface and Controller Status

Clearing and Resetting the Interface

Shutting Down and Restarting an Interface

Configuring Interface Link Status and Trunk Status Events

Resetting the Interface to the Default Configuration

Monitoring Interface and Controller Status

The Cisco IOS software for the Catalyst 4500 series switch contains commands that you can enter at the EXEC prompt to display information about the interface, including the version of the software and the hardware, the controller status, and statistics about the interfaces. The following table lists some of the interface monitoring commands. (You can display the full list of show commands by entering the show ? command at the EXEC prompt.) These commands are fully described in the Interface Command Reference.

To display information about the interface, perform this task:

 
Command
Purpose

Step 1 

Switch# show interfaces [type slot/interface]

Displays the status and configuration of all interfaces or of a specific interface.

Step 2 

Switch# show running-config 

Displays the configuration currently running in RAM.

Step 3 

Switch# show protocols [type slot/interface] 

Displays the global (system-wide) and interface-specific status of any configured protocol.

Step 4 

Switch# show version 

Displays the hardware configuration, software version, the names and sources of configuration files, and the boot images.


This example shows how to display the status of Fast Ethernet interface 5/5:

Switch# show protocols fastethernet 5/5 
FastEthernet5/5 is up, line protocol is up
Switch# 

Clearing and Resetting the Interface

To clear the interface counters shown with the show interfaces command, enter the following command:

Command
Purpose
Switch# clear counters {type slot/interface}

Clears interface counters.


This example shows how to clear and reset the counters on Fast Ethernet interface 5/5:

Switch# clear counters fastethernet 5/5 
Clear "show interface" counters on this interface [confirm] y 
Switch#
*Sep 30 08:42:55: %CLEAR-5-COUNTERS: Clear counter on interface FastEthernet5/5
by vty1 (171.69.115.10)
Switch#

The clear counters command (without any arguments) clears all the current interface counters from all interfaces.


Note The clear counters command does not clear counters retrieved with SNMP; it clears only those counters displayed with the EXEC show interfaces command.


Shutting Down and Restarting an Interface

You can disable an interface, which disables all functions on the specified interface and marks the interface as unavailable on all monitoring command displays. This information is communicated to other network servers through all dynamic routing protocols. The interface will not be mentioned in any routing updates.

To shut down an interface and then restart it, perform this task:

 
Command
Purpose

Step 1 

Switch(config)# interface {vlan vlan_ID} | 
{{fastethernet | gigabitethernet | 
tengigabitethernet} slot/port} | {port-channel 
port_channel_number}

Specifies the interface to be configured.

Step 2 

Switch(config-if)# shutdown 

Shuts down the interface.

Step 3 

Switch(config-if)# no shutdown 

Reenables the interface.

This example shows how to shut down Fast Ethernet interface 5/5:

Switch(config)# interface fastethernet 5/5 
Switch(config-if)# shutdown 
Switch(config-if)#
*Sep 30 08:33:47: %LINK-5-CHANGED: Interface FastEthernet5/5, changed state to a 
administratively down
Switch(config-if)# 

This example shows how to reenable Fast Ethernet interface 5/5:

Switch(config-if)# no shutdown 
Switch(config-if)#
*Sep 30 08:36:00: %LINK-3-UPDOWN: Interface FastEthernet5/5, changed state to up
Switch(config-if)# 

To verify whether an interface is disabled, enter the EXEC show interfaces command. An interface that has been shut down will appear as "administratively down."

Configuring Interface Link Status and Trunk Status Events

You can configure interface link status and trunk status events. On the Catalyst 4500 series switch, the following interface logging event notifications are supported both globally and per interface:

Enable/disable notification on the interface whenever its data link status is changed.

Enable/disable notification on the trunk interface whenever its trunking status is changed.

Use the [no] logging event link-status [use-global] command to enable/disable the interface link status event. Use the [no] logging event trunk-status [use-global] command to enable/disable the interface trunk status event.

Each interface link status logging event can be configured in one of the following states:

logging event link-status - Link status logging event is enabled explicitly on the interface regardless of the switch global setting.

no logging event link-status - Link status logging event is disabled explicitly on the interface regardless of the switch global setting.

logging event link-status use-global - This is the default link status logging event configuration on the interface; its configuration should follow the switch global link status logging event setting.

The interface trunk status logging event can be configured in the same configuration states.

Configuring Link Status Event Notification for an Interface

To enable/disable a link status logging event, enter one of the following commands:

Command
Purpose
Switch(config-if)# logging event link-status

Enables interface link status logging.

Switch(config-if)# no logging event link-status

Disables interface link status logging.

Switch(config-if)# logging event link-status use-global

Specifies the global default setting for interface link status logging.

Global Settings

You can also provide a global configuration for the corresponding logging event. A global configuration provides default logging settings for all interfaces. The [no] logging event link-status global command lets you enable/disable the interface link status logging for the entire switch. The [no] logging event trunk-status global command lets you enable/disable interface trunk status logging for the entire switch.

Each interface link status logging event, if not configured at the interface level, will use the following global logging event setting:

logging event link-status global - Link status logging event is enabled, if not configured on the interface.

no logging event link-status global - Link status logging event is disabled, if not configured on the interface.

The interface trunk status logging event has similar global configurations.

Configuring a Switch Global Link Status Logging Event

To enable/disable the global link status logging event, enter one of the following commands:

Command
Purpose
Switch(config-if)# logging event link-status global

Enables global link status logging.

Switch(config-if)# no logging event link-status global

Disables global link status logging.

Result

The following example displays a summary of the operating states for the interface logging event under different combinations of global and interface logging settings:

global setting       interface setting       actual logging state
--------------       -----------------       --------------------
     on                    on                       on
     off                   on                       on
     on                    off                      off
     off                   off                      off
     on                    default(use-global)      on
     off                   default(use-global)      off

The following example displays the configuration and logging message output for link status and trunk status logging events:

//
// The global link status and trunk status logging events are enabled.
//
Switch# show running | include logging
show running | include logging
logging event link-status global
logging event trunk-status global
Switch#

//
// The interface link status and trunk status logging settings
// are set to default values, which follow regardless of the global
// setting.
//
Switch# show running interface g1/4
Building configuration...

Current configuration: 97 bytes
!
interface GigabitEthernet1/4
 switchport trunk encapsulation dot1q
 switchport mode trunk
end
Switch#

//
// The trunk status logging messages for the interface are 
// displayed whenever the interface trunking status is changed.
// Here we change the other end node's trunking encapsulation 
// from dot1q to isl.
//
3d00h: %DTP-5-ILGLCFG: Illegal config(on,isl--on,dot1q) on Gi1/4
3d00h: %DTP-5-ILGLCFG: Illegal config(on,isl--on,dot1q) on Gi1/4
3d00h: %DTP-5-ILGLCFG: Illegal config(on,isl--on,dot1q) on Gi1/4

//
// The link and trunk status logging message for the interface 
// are displayed whenever the interface link status is changed.
// Here we do a "shut" and "no shut" on the other end link node.
//
3d00h: %DTP-5-NONTRUNKPORTON: Port Gi1/4 has become non-trunk
3d00h: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet1/4, changed state to down
3d00h: %LINK-3-UPDOWN: Interface GigabitEthernet1/4, changed state to
down
3d00h: %LINK-3-UPDOWN: Interface GigabitEthernet1/4, changed state to up
3d00h: %DTP-5-TRUNKPORTON: Port Gi1/4 has become dot1q trunk
3d00h: %LINEPROTO-5-UPDOWN: Line protocol on Interface
GigabitEthernet1/4, changed state to up 

Resetting the Interface to the Default Configuration

If you have configured a interface with many command lines and you want to clear all the configuration on that interface, you can use the default interface global configuration command, as follows:

Switch(config)# default interface fastEthernet 3/5
Interface FastEthernet3/5 set to default configuration

This command will clear all the configurations and shutdown the interface:

Switch# show run interface fastethernet 3/5
Building configuration...

Current configuration : 58 bytes
!
interface FastEthernet3/5
 no ip address
 shutdown
end