- Supported Hardware
- Supervisor Engines
- Policy Feature Cards
- Distributed and Centralized Forwarding Cards
- Switch Fabric Modules
- Transceivers
- 10-Gigabit Ethernet Switching Modules
- Gigabit Ethernet Switching Modules
- Power over Ethernet Daughtercards
- 10/100/1000 Ethernet Switching Modules
- Fast Ethernet Switching Modules
- Ethernet/Fast Ethernet (10/100) Switching Modules
- Ethernet Switching Modules
- Optical Services Modules (OSMs)
- Shared Port Adapter (SPA) Interface Processors (SIPs)
- Shared Port Adapters (SPAs)
- Services SPA Carrier (SSC)
- Services SPAs
- FlexWAN and Enhanced FlexWAN Modules
- FlexWAN and Enhanced FlexWAN Module Port Adapters
- Service Modules
- Application Control Engine (ACE) Module
- Wireless Services Module (WiSM)
- Application-Oriented Networking Module
- WebVPN Services Module
- Anomaly Guard Module
- Traffic Anomaly Detector Module
- Wireless LAN Service Module (WLSM)
- Persistent Storage Device (PSD) Module
- Multi-Processor WAN Application Module (MWAM)
- Content Services Gateway (CSG) Module
- Communication Media Module (CMM)
- IPsec VPN Acceleration Services Module
- Content Switching Module with SSL (CSM-S)
- Content Switching Module (CSM)
- Firewall Services Module
- Intrusion Detection System Modules (IDSMs)
- Network Analysis Modules (NAMs)
- Secure Sockets Layer (SSL) Services Module
- Fan Trays
- Power Supplies
- Chassis
Supported Hardware
These sections describe the hardware supported in Release 12.2SX:
•Distributed and Centralized Forwarding Cards
•10-Gigabit Ethernet Switching Modules
•Gigabit Ethernet Switching Modules
•Power over Ethernet Daughtercards
•10/100/1000 Ethernet Switching Modules
•Fast Ethernet Switching Modules
•Ethernet/Fast Ethernet (10/100) Switching Modules
•Optical Services Modules (OSMs)
•Shared Port Adapter (SPA) Interface Processors (SIPs)
•FlexWAN and Enhanced FlexWAN Modules
•FlexWAN and Enhanced FlexWAN Module Port Adapters

Note•
Use the values in the "Power Required" column to determine the exact power requirements for your configuration to ensure that you are within the power budget.
•Daughtercard power is shown separately.
•Enter the show power command to display current system power usage.
Flash Memory Device Summary
•bootflash: on the RP of all supervisor engines.
•sup-bootdisk: on these supervisor engines:
–Supervisor Engine 720 with a CompactFlash adapter and CompactFlash card.
–Supervisor Engine 32.
•sup-bootflash: on these supervisor engines:
–Supervisor Engine 720 without a CompactFlash adapter and CompactFlash card.
–Supervisor Engine 2.
•disk0: on these supervisor engines:
–Supervisor Engine 720.
–Supervisor Engine 32.
–Supervisor Engine 2 with a PCMCIA Advanced Technology Attachment (ATA) FlashDisk device.
•disk1: on a Supervisor Engine 720.
•slot0: on a Supervisor Engine 2 without a PCMCIA Advanced Technology Attachment (ATA) FlashDisk device.
Supervisor Engines
•Supervisor Engine 720 (CAT6000-SUP720/MSFC3, 7600-SUP720/MSFC3)
•Supervisor Engine 32 (CAT6000-SUP32/MSFC2A, 7600-SUP32/MSFC2A)
•Supervisor Engine 2 (CAT6000-SUP2/MSFC2, 7600-SUP2/MSFC2)
Supervisor Engine 720 (CAT6000-SUP720/MSFC3, 7600-SUP720/MSFC3)
•Supervisor Engine 720 Common Features
•Supervisor Engine 720 with PFC3BXL
•Supervisor Engine 720 with PFC3B
•Supervisor Engine 720 with PFC3A
Supervisor Engine 720 Common Features
•Integrated 720-Gbps Switch Fabric
•64-MB bootflash device or CompactFlash adapter with 512 MB CompactFlash card (WS-CF-UPG=):
–64-MB bootflash device (sup-bootflash:) supported in all releases
–WS-CF-UPG= (sup-bootdisk:) supported in:
—Release 12.2(18)SXE5 and later releases
—Release 12.2(18)SXF and later releases
–See this publication:
http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_17277.html
•2 CompactFlash Type II slots (disk0: and disk1:)

Note Some Supervisor Engine 720 Release 12.2SX images are larger than the bootflash device and must be stored on a CompactFlash card (sup-bootdisk: or disk0: or disk1:).
•Two Ethernet uplink ports:
–1-MB packet buffer per port
–Port 1—Gigabit Ethernet SFP
–Port 2—Configurable as Gigabit Ethernet SFP or 10/100/1000 Mbps RJ-45
•QoS port architecture (Rx/Tx): 1p1q4t/1p2q2t
•Port grouping:
–Number of ports: 2
–Number of port groups: 1
–Port ranges per port group: 1-2
•Supervisor Engine 720 requires a high-capacity fan tray (see the "Fan Trays" section)
•Supervisor Engine 720 requires a 2500W or higher power supply (see the "Power Supplies" section)
Supervisor Engine 720 with PFC3BXL
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
7.82 A@42 V |
Supervisor Engine 720 with PFC3BXL: • • • – – |
12.2(17b)SXA |
Note • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12409.html |
Supervisor Engine 720 with PFC3B
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
6.72 A@42 V |
Supervisor Engine 720 with PFC3B: • • • – – |
12.2(17d)SXB1 |
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12409.html • – – http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_16220.html • – – http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/OL_20611.html |
Supervisor Engine 720 with PFC3A
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
7.50 A@42 V |
Supervisor Engine 720 with PFC3A: • • • – – |
12.2(14)SX |
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12409.html • – – http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_16220.html • |
Supervisor Engine 32 (CAT6000-SUP32/MSFC2A, 7600-SUP32/MSFC2A)
These sections describe the Supervisor Engine 32:
•Supervisor Engine 32 Restrictions
•Supervisor Engine 32 Features
Supervisor Engine 32 Restrictions
•Supervisor Engine 32 requires a high-capacity fan tray (see the "Fan Trays" section).
•In some chassis, Supervisor Engine 32 requires a high-capacity power supply (see the "Power Supplies" section).
•Supervisor Engine 32 does not support this hardware:
–WS-F6K-PFC3A Policy Feature Card 3A (PFC3A)
–WS-F6K-PFC3BXL Policy Feature Card 3BXL (PFC3BXL)
–DFCs (installed DFCs do not power up with a Supervisor Engine 32)
–Switch Fabric Modules
–These switching modules:
—WS-X6704-10GE 4-port 10-Gigabit Ethernet XENPAK
—WS-X6748-SFP 48-port Gigabit Ethernet SFP
—WS-X6724-SFP 24-port Gigabit Ethernet SFP
—WS-X6816-GBIC 16-port Gigabit Ethernet GBIC
—WS-X6748-GE-TX 48-port 10/100/1000 RJ-45
–7600-SIP-600 SPA Interface Processor-600
–Optical Services Modules (OSMs)
–WS-X6182-2PA FlexWAN Module (the WS-X6582-2PA Enhanced FlexWAN Module is supported)
–CISCO7603 3-slot chassis
–These service modules:
—WS-SVC-WISM-1-K9 Wireless Services Module (WiSM)
—WS-SVC-AON-1-K9 Application-Oriented Networking (AON) Module
—WS-SVC-AGM-1-K9 Anomaly Guard Module
—WS-SVC-ADM-1-K9 Traffic Anomaly Detector Module
—WS-SVC-CSG-1 Content Services Gateway (CSG)
—WS-X6066-SLB-APC Content Switching Module (CSM)
—WS-X6066-SLB-S-K9 Content Switching Module with SSL (CSM-S)
—WS-SVC-PSD-1 Persistent Storage Device (PSD) Module
—WS-SVC-WLAN-1-K9 Wireless LAN service module
—WS-SVC-IPSEC-1 IPsec VPN acceleration services module
•Releases earlier than Release 12.2(18)SXF do not support Cisco IOS SLB with Supervisor Engine 32.
•Supervisor Engine 32 cannot support these software features and commands:
–Egress multicast replication
–Multicast replication mode detection
–All fabric configuration commands
Supervisor Engine 32 Features
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.39 A@42 V |
Supervisor Engine 32: • • • • • • • • • – – – |
12.2(18)SXF |
|
1.89 A@42 V |
||
Note |
Supervisor Engine 2 (CAT6000-SUP2/MSFC2, 7600-SUP2/MSFC2)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
WS-X6K-S2-MSFC2 |
3.46 A@42 V |
Supervisor Engine 2 with Policy Feature Card 2 (PFC2): • • • • • • • |
12.2(17d)SXB |
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_13488.html • – http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_6953.html – http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12693.html – http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12667.html • |
Policy Feature Cards
•Policy Feature Card Guidelines and Restrictions
Policy Feature Card Guidelines and Restrictions
•A Supervisor Engine 2 always has a PFC2; there are no PFC options for Supervisor Engine 2.
•The PFC2 supports a theoretical maximum of 128 K MAC addresses (32 K MAC addresses recommended maximum).
•The PFC3 supports a theoretical maximum of 64 K MAC addresses (32 K MAC addresses recommended maximum).
•The PFC3 partitions the hardware FIB table to route IPv4 unicast, IPv4 multicast, MPLS, and IPv6 unicast and multicast traffic in hardware. Traffic for routes that do not have entries in the hardware FIB table are routed by the MSFC in software.
The defaults for XL mode are:
–IPv4 unicast and MPLS—512,000 routes
–IPv4 multicast and IPv6 unicast and multicast—256,000 routes
The defaults for Non-XL mode are:
–IPv4 unicast and MPLS—192,000 routes
–IPv4 multicast and IPv6 unicast and multicast—32,000 routes

Note The size of the global internet routing table plus any local routes might exceed the non-XL mode default partition sizes.
These are the theoretical maximum numbers of routes for the supported protocols (the maximums are not supported simultaneously):
–XL mode:
· IPv4 and MPLS—Up to 1,007,000 routes
· IPv4 multicast and IPv6 unicast and multicast—Up to 503,000 routes
· IPv4 and MPLS—Up to 239,000 routes
· IPv4 multicast and IPv6 unicast and multicast—Up to 119,000 routes
Enter the mls cef maximum-routes command to repartition the hardware FIB table. IPv4 unicast and MPLS require one hardware FIB table entry per route. IPv4 multicast and IPv6 unicast and multicast require two hardware FIB table entries per route. Changing the partition for one protocol makes corresponding changes in the partitions of the other protocols. You must enter the reload command to put configuration changes made with the mls cef maximum-routes command into effect.

Note With a non-XL-mode system, if your requirements cannot be met by repartitioning the hardware FIB table, upgrade components as necessary to operate in XL mode.
•You cannot use one type of PFC3 (PFC3BXL, PFC3B, or PFC3A) on one supervisor engine and a different type on the other supervisor engine for redundancy. You must use identical policy feature cards for redundancy.
•With Release 12.2(17d)SXB and later releases, enter the show platform hardware pfc mode command to display the PFC3 mode.
•With Release 12.2(17b)SXA and Release 12.2(17b)SXA2, enter the show platform earl-mode command to display the PFC3 mode.
•PFC3A—These restrictions apply to a configuration with a PFC3A and these DFCs:
–PFC3A and DFC3A—No restrictions (PFC3A mode).
–PFC3A and DFC3B—The PFC3A restricts DFC3B functionality: the DFC3B functions as a DFC3A (PFC3A mode).
–PFC3A and DFC3BXL—The PFC3A restricts DFC3BXL functionality: the DFC3BXL functions as a DFC3A (PFC3A mode).
–PFC3A and DFC3C—The PFC3A restricts DFC3C functionality: the DFC3C functions as a DFC3A (PFC3A mode).
–PFC3A and DFC3CXL—The PFC3A restricts DFC3CXL functionality: the DFC3CXL functions as a DFC3A (PFC3A mode).
•PFC3B—These restrictions apply to a configuration with a PFC3B and these DFCs:
–PFC3B and DFC3A—PFC3B functionality is restricted by the DFC3A: after a reload with a DFC3A-equipped module installed, the PFC3B functions as a PFC3A (PFC3A mode).
–PFC3B and DFC3B—No restrictions (PFC3B mode).
–PFC3B and DFC3BXL—The PFC3B restricts DFC3BXL functionality: after a reload with a DFC3BXL-equipped module installed, the DFC3BXL functions as a DFC3B (PFC3B mode).
–PFC3B and DFC3C—The PFC3B restricts DFC3C functionality: the DFC3C functions as a DFC3B (PFC3B mode).
–PFC3B and DFC3CXL—The PFC3B restricts DFC3CXL functionality: the DFC3CXL functions as a DFC3B (PFC3B mode).
•PFC3BXL—These restrictions apply to a configuration with a PFC3BXL and these DFCs:
–PFC3BXL and DFC3A—PFC3BXL functionality is restricted by the DFC3A: after a reload with a DFC3A-equipped module installed, the PFC3BXL functions as a PFC3A (PFC3A mode).
–PFC3BXL and DFC3B—PFC3BXL functionality is restricted by the DFC3B: after a reload with a DFC3B-equipped module installed, the PFC3BXL functions as a PFC3B (PFC3B mode).
–PFC3BXL and DFC3BXL—No restrictions (PFC3BXL mode).
–PFC3BXL and DFC3C—Each restricts the functionality of the other: the PFC3BXL functions as a PFC3B and the DFC3C functions as a DFC3B (PFC3B mode).
–PFC3BXL and DFC3CXL—The PFC3BXL restricts DFC3CXL functionality: the DFC3CXL functions as a DFC3BXL (PFC3BXL mode).
•Summary of the PFC modes:
–PFC3A mode—Operating mode with a PFC3A or any DFC3As
–PFC3B mode—Operating mode with PFC3B and any DFC3Bs or DFC3BXLs
–PFC3BXL mode—Operating mode with PFC3BXL and any DFC3BXLs
•The features that require the PFC3BXL or PFC3B are not supported in PFC3A mode.
•With a PFC3BXL or PFC3B and no DFC3A-equipped switching modules installed at bootup, any DFC3A-equipped switching module installed after bootup remain powered down.
•To use DFC3A-equipped switching modules with a PFC3BXL or PFC3B, the DFC3A-equipped switching modules must be installed at bootup.
•To use DFC3B-equipped switching modules with a PFC3BXL, the DFC3B-equipped switching modules must be installed at bootup.
Policy Feature Card 3BXL
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.57 A@42 V |
Policy Feature Card 3BXL (PFC3BXL) |
|
Supported only with Supervisor Engine 720 |
12.2(17b)SXA |
||
Note • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_16220.html |
Policy Feature Card 3B
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.25 A@42 V |
Policy Feature Card 3B (PFC3B) |
|
With Supervisor Engine 720 |
12.2(17d)SXB1 |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
Note • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_16220.html |
Policy Feature Card 3A
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.25 A@42 V |
Policy Feature Card 3A (PFC3A) |
|
Supported only with Supervisor Engine 720 |
12.2(14)SX |
||
Note • • |
Distributed and Centralized Forwarding Cards
•Distributed Forwarding Card 3CXL
•Distributed Forwarding Card 3C
•Distributed Forwarding Card 3BXL
•Distributed Forwarding Card 3B
•Distributed Forwarding Card 3A
•Distributed Forwarding Card (WS-F6K-DFC)
•Centralized Forwarding Card (WS-F6700-CFC)

Note See the "Policy Feature Cards" section for Policy Feature Cards (PFC) and Distributed Forwarding Card (DFC) restrictions.
Distributed Forwarding Card 3CXL
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.35 A@42 V |
Distributed Forwarding Card 3CXL (DFC3CXL) for use on CEF720 modules |
|
Supported only with Supervisor Engine 720 and WS-X6708-10GE |
12.2(18)SXF5 |
Distributed Forwarding Card 3C
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
1.65 A@42 V |
Distributed Forwarding Card 3C (DFC3C) for use on CEF720 modules |
|
Supported only with Supervisor Engine 720 and WS-X6708-10GE |
12.2(18)SXF5 |
Distributed Forwarding Card 3BXL
WS-F6700-DFC3BXL
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
3.30 A@42 V |
Distributed Forwarding Card 3BXL (DFC3BXL) for use on CEF720 modules |
|
Supported only with Supervisor Engine 720 |
12.2(17d)SXB6 |
||
Note • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_15893.html |
WS-F6K-DFC3BXL
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
1.47 A@42 V |
Distributed Forwarding Card 3BXL (DFC3BXL) for use on dCEF256 and CEF256 modules |
|
Supported only with Supervisor Engine 720 |
12.2(18)SXD3 |
||
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12409.html • – – • • • |
Distributed Forwarding Card 3B
WS-F6700-DFC3B
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.70 A@42 V |
Distributed Forwarding Card 3B (DFC3B) for use on CEF720 modules |
|
Supported only with Supervisor Engine 720 |
12.2(17d)SXB6 |
||
Note • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_15893.html |
WS-F6K-DFC3B
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
1.67 A@42 V |
Distributed Forwarding Card 3B (DFC3B) for use on dCEF256 and CEF256 modules |
|
Supported only with Supervisor Engine 720 |
12.2(18)SXD3 |
||
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12409.html • – – • • • |
Distributed Forwarding Card 3A
WS-F6700-DFC3A
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
3.00 A@42 V |
Distributed Forwarding Card 3A (DFC3A) for use on CEF720 modules |
|
Supported only with Supervisor Engine 720 |
12.2(17a)SX |
||
Note • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12409.html |
WS-F6K-DFC3A
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.57 A@42 V |
Distributed Forwarding Card 3A (DFC3A) for use on dCEF256 and CEF256 modules |
|
Supported only with Supervisor Engine 720 |
12.2(14)SX |
||
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12409.html • – – • • • |
Distributed Forwarding Card (WS-F6K-DFC)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.10 A@42 V |
Distributed Forwarding Card (DFC) for use on dCEF256 and CEF256 modules |
|
Supported only with Supervisor Engine 2 Note |
12.2(17d)SXB |
||
Note • • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_12409.html |
Centralized Forwarding Card (WS-F6700-CFC)
Switch Fabric Modules

Note•
Switch fabric modules are supported only with Supervisor Engine 2.
•Except in 13-slot chassis, WS-X6500-SFM2 and WS-C6500-SFM can be used together to provide redundancy.
•3-slot chassis do not support WS-X6500-SFM2 or WS-C6500-SFM.
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
3.09 A@42 V |
Switch Fabric Module, version 2, to support dCEF256 modules |
|
Supported only with Supervisor Engine 2 |
12.2(17d)SXB |
||
Note |
|||
|
2.79 A@42 V |
Switch Fabric Module to support dCEF256 modules |
|
Supported only with Supervisor Engine 2 |
12.2(17d)SXB |
||
Note |
Transceivers
•Small Form-Factor Pluggable (SFP) Modules
•Gigabit Interface Converters (GBICs)
X2 Modules

Note WS-X6708-10GE does not support X2 modules shipped before the release of the WS-X6708-10GE switching module. The unsupported X2 modules are labeled with a number that ends with -01.
XENPAKs
Small Form-Factor Pluggable (SFP) Modules
These sections describe SFPs:
Gigabit Ethernet SFPs

Note See the "Unsupported Hardware" section for information about unsupported DWDM-SFPs.
Fast Ethernet SFPs

Note Only WS-X6148-FE-SFP supports these Fast Ethernet SFPs.
Gigabit Interface Converters (GBICs)

Note The support listed in this section applies to all modules that use GBICs, including OSM LAN ports and OSM Gigabit Ethernet WAN ports, except as noted.
10-Gigabit Ethernet Switching Modules
(append "=" for spares) |
Required |
|
|
---|---|---|---|
(WS-X6708-10GE with WS-F6700-DFC3C ) |
10.58A @42 V |
8-port 10-Gigabit Ethernet X2module • • • • • |
|
(WS-X6708-10GE with WS-F6700-DFC3CXL) |
11.28A @ 42V |
||
Supported only with Supervisor Engine 720 |
12.2(18)SXF5 |
||
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/rommon/OL_6143.html • • • • • Full NEBS-compliance requires support for operating temperatures up to 55° C, which is available in all other chassis that support WS-X6708-10GE. ![]() Note • • • • • |
|||
|
6.28 A@42 V |
4-port 10-Gigabit Ethernet XENPAK • • • • • • – – • • |
|
Supported only with Supervisor Engine 720 |
12.2(17a)SX |
||
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/rommon/OL_6143.html • – – – – • • • • • |
|||
|
3.30 A@42 V |
1-port 10-Gigabit Ethernet • – – – • • • |
|
|
|||
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
Note |
|||
|
|||
|
10GBASE-LR serial 1310 nm long-reach OIM |
12.2(14)SX |
|
|
10GBASE-ER serial 1550 nm extended-reach OIM |
12.2(14)SX |
Gigabit Ethernet Switching Modules
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
5.32 A@42 V |
48-port Gigabit Ethernet SFP • • • • • • – – • • |
|
Supported only with Supervisor Engine 720 |
12.2(17d)SXB |
||
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/rommon/OL_6143.html • – – – – • • • • • • |
|||
|
2.23 A@42 V |
24-port Gigabit Ethernet SFP • • • • • • – – • |
|
Supported only with Supervisor Engine 720 |
12.2(17a)SX |
||
WS-X6724-SFP HW rev 2.3 or later (supported only with Supervisor Engine 720) |
12.2(17d)SXB1 |
||
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/rommon/OL_6143.html • – – – – • • • • • • |
|||
|
16-port Gigabit Ethernet GBIC • • • • |
||
3.84 A@42 V |
With Supervisor Engine 720 |
12.2(14)SX |
|
5.94 A@42 V |
With Supervisor Engine 2 |
12.2(17d)SXB |
|
Note • – – – • • |
|||
|
3.62 A@42 V |
16-port Gigabit Ethernet GBIC • • – – – • • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
3.40 A@42 V |
16-port Gigabit Ethernet GBIC • • – – – • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
Note • – – • • • |
|||
|
2.81 A@42 V |
16-port Gigabit Ethernet GBIC • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.50 A@42 V |
16-Port Gigabit Ethernet MT-RJ • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
5.15 A@42 V |
16-port Gigabit Ethernet RJ-45 • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.00 A@42 V |
8-port Gigabit Ethernet GBIC • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.00 A@42 V |
8-port Gigabit Ethernet GBIC • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
Note • • |
Power over Ethernet Daughtercards

Note The power over Ethernet (PoE) daughtercard "Power Required" values do not include the power drawn by phones.
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
0.42 A@42 V |
IEEE 802.3af PoE daughtercard for WS-X6148X2-RJ-45 and WS-X6196-RJ-21. |
|
With Supervisor Engine 720 |
12.2(18)SXF |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(18)SXF2 |
||
WS-F6K-48-AF |
0.18 A@42 V |
IEEE 802.3af PoE daughtercard for: Note WS-F6K-GE48-AF and WS-F6K-48-AF are not FRUs for these switching modules: • • |
|
With Supervisor Engine 720 |
12.2(17d)SXB |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
0.42 A@42 V |
PoE daughtercard for WS-X6548-GE-TX and WS-X6148-GE-TX |
|
With Supervisor Engine 720 |
12.2(17a)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
None |
PoE daughtercard for: |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
10/100/1000 Ethernet Switching Modules
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
7.00 A@42 V |
48-port 10/100/1000 RJ-45 • • • • • • – – • • |
|
Supported only with Supervisor Engine 720 |
12.2(17a)SX |
||
Note • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/rommon/OL_6143.html • – – – – • • • • • |
|||
|
2.98 A@42 V |
48-port 10/100/1000 Mbps • • • • • • • • |
|
WS-X6548V-GE-TX |
3.40 A@42 V |
||
WS-X6548-GE-45AF |
3.16 A@42 V |
||
With Supervisor Engine 720 |
12.2(17a)SX |
||
WS-F6K-GE48-AF or WS-F6K-48-AF |
12.2(17d)SXB |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
WS-F6K-GE48-AF or WS-F6K-48-AF |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-F6K-GE48-AF or WS-F6K-48-AF |
12.2(17d)SXB |
||
Note • • – – – – – – |
|||
|
2.50 A@42 V |
48-port 10/100/1000 Mbps • • • • • • |
|
WS-X6148A-GE-45AF |
2.68 A@42 V |
||
With Supervisor Engine 720 |
12.2(18)SXF |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(18)SXF2 |
||
Note • • |
|||
|
2.47 A@42 V |
48-port 10/100/1000 Mbps • • • • • • • |
|
WS-X6148V-GE-TX |
2.89 A@42 V |
||
WS-X6148-GE-45AF |
2.65 A@42 V |
||
With Supervisor Engine 720 |
12.2(17a)SX |
||
WS-F6K-GE48-AF or WS-F6K-48-AF |
12.2(17d)SXB |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
WS-F6K-GE48-AF or WS-F6K-48-AF |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-F6K-GE48-AF or WS-F6K-48-AF |
12.2(17d)SXB |
||
Note • • • • • • |
|||
|
3.45 A@42 V |
16-port 10/100/1000BASE-T • • – – – • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
Fast Ethernet Switching Modules
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.30 A@42 V |
48-port 100BASE-FX • • • |
|
With Supervisor Engine 720 |
12.2(18)SXF |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(18)SXF2 |
||
|
1.90 A@42 V |
24-port 100FX Ethernet multimode • • – – – • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
1.52 A@42 V |
24-port 100FX Ethernet • • • • |
|
WS-X6324-100FX-MM |
1.52 A@42 V |
||
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
1.90 A@42 V |
24-port 100FX Ethernet Multimode MT-RJ • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
Ethernet/Fast Ethernet (10/100) Switching Modules
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.90 A@42 V |
48-port 10/100TX RJ-45 • • – – – • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.90 A@42 V |
48-port 10/100TX RJ-21 • • – – – • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.65 A@42 V |
96-port 10/100TX RJ-45 • • • |
|
WS-X6148X2-45AF |
3.07 A@42 V |
||
With Supervisor Engine 720 |
12.2(18)SXF3 |
||
With Supervisor Engine 32 |
12.2(18)SXF3 |
||
With Supervisor Engine 2 |
12.2(18)SXF3 |
||
|
2.74 A@42 V |
96-port 10/100TX RJ-21 • • • |
|
WS-X6196-21AF |
3.16 A@42 V |
||
With Supervisor Engine 720 |
12.2(18)SXF3 |
||
With Supervisor Engine 32 |
12.2(18)SXF3 |
||
With Supervisor Engine 2 |
12.2(18)SXF3 |
||
|
2.39 A@42 V |
48-port 10/100TX RJ-45 • • • • • |
|
WS-X6348-RJ-45V |
2.39 A@42 V |
||
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.39 A@42 V |
48-port 10/100TX RJ-21 • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.69 A@42 V |
48-port 10/100TX RJ-45 • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.69 A@42 V |
48-port 10/100TX RJ-21 • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
2.69 A@42 V |
48-port 10/100TX RJ-21 • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
1.00 A@42 V |
48-port 10/100TX RJ-45 • • • • • |
|
WS-X6148A-45AF |
2.57 A@42 V |
||
With Supervisor Engine 720 |
12.2(18)SXF |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(18)SXF2 |
||
|
2.39 A@42 V |
48-port 10/100TX RJ-45 • • • • • • |
|
WS-X6148-RJ45V |
2.39 A@42 V |
||
WS-X6148-45AF |
2.57 A@42 V |
||
With Supervisor Engine 720 |
12.2(14)SX |
||
WS-F6K-48-AF with Supervisor Engine 720 |
12.2(17d)SXB |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
WS-F6K-48-AF with Supervisor Engine 32 |
|||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-F6K-48-AF with Supervisor Engine 2 |
|||
|
2.39 A@42 V |
48-port 10/100TX RJ-21 • • • • • • |
|
WS-X6148-RJ21V |
2.39 A@42 V |
||
WS-X6148-21AF |
2.57 A@42 V |
||
With Supervisor Engine 720 |
12.2(14)SX |
||
WS-F6K-48-AF with Supervisor Engine 720 |
12.2(17d)SXB |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
WS-F6K-48-AF with Supervisor Engine 32 |
|||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-F6K-48-AF with Supervisor Engine 2 |
Ethernet Switching Modules
Optical Services Modules (OSMs)
•OSM Guidelines and Restrictions
•CT3/T1 Channelized/Unchannelized
OSM Guidelines and Restrictions
•Cisco IOS Software modularity does not support OSMs.
•Supervisor Engine 32 does not support OSMs.
•With Release 12.2(18)SXD and later releases, OSMs require a minimum of 128 MB of dynamic random-access memory (SDRAM)—See this publication for memory upgrade procedures:
•OSMs are CEF256 modules.
•OSM WAN port numbering starts with 1.
•On OSMs with Gigabit Ethernet GBIC Layer 2 LAN ports:
–OSM LAN port numbering starts with 1.
–The LAN ports are in a single port group.
•In releases earlier than Release 12.2(18)SXD1, WS-SVC-WLAN-1-K9 has not been tested with OSMs.
•The OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs have been tested with the service modules and WS-SUP720.
•In releases earlier than Release 12.2(18)SXD1, except for the OSM-2+4GE-WAN+ and the OC-12 Packet-over-SONET OSMs, the following service modules have not been tested with other OSMs:
–WS-X6066-SLB-APC content switching module (CSM)
–WS-SVC-IDSM2-K9 intrusion detection system module
–WS-SVC-NAM-2 and WS-SVC-NAM-1 network analysis modules (NAMs)
–WS-SVC-SSL-1 SSL services module
Gigabit Ethernet WAN
OC-48 Packet over SONET

Note Also has four Layer 2 LAN ports.
OC-48 DPT/Packet over SONET

Note Also has four Layer 2 LAN ports.
OC-12 Packet over SONET

Note Also has four Layer 2 LAN ports.
OC-3 Packet over SONET

Note Also has four Layer 2 LAN ports.
OC-12 Channelized

Note Also has four Layer 2 LAN ports.
CT3/T1 Channelized/Unchannelized

Note OSM-12CT3/T1 has mini-SMB connectors for use with 75-Ohm copper coax cable.
OC-12 ATM

Note Also has four Layer 2 LAN ports.
Shared Port Adapter (SPA) Interface Processors (SIPs)

Note•
See the "FPD Image Packages" section for information about additional procedures required to support SIPs with Release 12.2(18)SXE and later releases.
•7600-SIP-400 and 7600-SIP-600 are not supported in PFC3A mode.
•With releases earlier than Release 12.2(18)SXF7, Cisco IOS Software modularity does not support SIPs.
•In Release 12.2(18)SXF7 and later releases, Cisco IOS Software Modularity supports 7600-SIP-400 and 7600-SIP-200.
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
8.14 A@42 V |
SPA Interface Processor-600 (not supported in PFC3A mode) Note |
|
Supported only with Supervisor Engine 720 |
12.2(18)SXF |
||
Note • • • |
|||
|
6.31 A@42 V |
SPA Interface Processor-400 (not supported in PFC3A mode) |
|
With Supervisor Engine 720 |
12.2(18)SXE |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
|
5.72 A@42 V |
SPA Interface Processor-200 |
|
With Supervisor Engine 720 |
12.2(18)SXE |
||
With Supervisor Engine 32 |
12.2(18)SXF |
Shared Port Adapters (SPAs)
These sections describe SPAs:
•SFPs for OC3 and OC12 POS and ATM SPAs

Note•
With releases earlier than Release 12.2(18)SXF7, Cisco IOS Software modularity does not support SIPs.
•In Release 12.2(18)SXF7 and later releases, Cisco IOS Software Modularity supports 7600-SIP-400 and 7600-SIP-200.
Ethernet SPAs
These sections describe Ethernet SPAs:
10-Gigabit Ethernet SPAs
Gigabit Ethernet SPAs
POS SPAs
(append "=" for spares) |
|
|
|
---|---|---|---|
|
1-Port OC-48 POS/RPR SPA Note |
12.2(18)SXF10 |
|
|
1-port OC-192c/STM-64 POS/RPR SPA, VSR-1 |
12.2(18)SXF2 |
|
|
2-port OC-3c/STM-1c POS SPA Note |
12.2(18)SXE |
|
|
4-port OC-3c/STM-1c POS SPA Note |
12.2(18)SXE |
|
|
1-port OC-12c/STM-4c POS SPA Note |
12.2(18)SXE |
|
|
1-port OC-192c/STM-64 POS/RPR SPA, SM-LR |
12.2(18)SXF |
|
|
1-port OC-192c/STM-64 POS/RPR SPA, XFP Optics |
12.2(18)SXF |
|
|
|||
XFP-10GLR-OC192SR Single-Mode (SM) Short Reach (SR) |
|||
XFP-10GER-OC192IR Single-Mode (SM) Intermediate Reach (IR-2) |
|||
|
1-port OC-192c/STM-64 POS/RPR SPA, VSR-1 |
12.2(18)SXF1 |
ATM SPAs
(append "=" for spares) |
|
|
|
---|---|---|---|
|
2-port OC-3c/STM-1c ATM SPA Note |
12.2(18)SXE |
|
|
4-port OC-3c/STM-1c ATM SPA Note |
12.2(18)SXE |
|
|
1-Port OC-12c/STM-4c ATM SPA Note |
12.2(18)SXE |
|
|
1 port OC-48c/STM-16 ATM SPA |
12.2(18)SXF |
SFPs for OC3 and OC12 POS and ATM SPAs
Serial SPAs
Services SPA Carrier (SSC)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
5.43 A@42 V |
Services SPA Carrier (SSC) |
|
With Supervisor Engine 720 |
12.2(18)SXE2 |
||
With Supervisor Engine 32 |
12.2(18)SXF2 |
||
Note • • |
Services SPAs

Note See the "FPD Image Packages" section for information about additional procedures required to support SPA-IPSEC-2G with Release 12.2(18)SXE and later releases.
FlexWAN and Enhanced FlexWAN Modules

Note•
In releases earlier than Release 12.2(18)SXD1, WS-SVC-WLAN-1-K9 has not been tested with the FlexWAN or Enhanced FlexWAN modules.
•The following service modules have not been tested with the Enhanced FlexWAN module and Release 12.2(17b)SXA, Release 12.2(17b)SXA2, or Release 12.2(17d)SXB:
–WS-X6066-SLB-APC content switching module (CSM)
–WS-SVC-IDSM2-K9 intrusion detection system module
–WS-SVC-NAM-2 and WS-SVC-NAM-1 network analysis modules (NAMs)
–WS-SVC-SSL-1 SSL services module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.50 A@42 V |
Enhanced FlexWAN Module; CEF256 |
|
With Supervisor Engine 720 |
12.2(17b)SXA |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
Note |
|||
|
2.38 A@42 V |
FlexWAN Module |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
Note • • |
FlexWAN and Enhanced FlexWAN Module Port Adapters
(append "=" for spares) |
|
|
---|---|---|
|
2-port Fast Ethernet Port Adapter (supported only in WS-X6582-2PA) |
12.2(18)SXE |
|
1-port Fast Ethernet Port Adapter (supported only in WS-X6582-2PA) |
12.2(18)SXE |
|
1-port Packet over SONET OC3c/STM1 Port Adapter |
12.2(18)SXE |
|
2-port POS OC3c/STM1 |
12.2(17b)SXA |
|
||
|
Short range, multimode fiber |
12.2(17b)SXA |
|
Intermediate range, single-mode fiber |
12.2(17b)SXA |
|
Long range, single-mode fiber |
12.2(17b)SXA |
PA-POS-OC3SMI PA-POS-OC3SML |
Packet over SONET (OC-3) |
12.2(14)SX |
|
1-port ATM OC-3c/STM-1 multimode port adapter, enhanced |
12.2(14)SX |
|
1-port ATM OC-3c/STM-1 single-mode (IR) port adapter, enhanced |
12.2(14)SX |
|
1-port ATM OC-3c/STM-1 single-mode (LR) port adapter, enhanced |
12.2(14)SX |
|
1-port ATM DS3 port adapter, enhanced |
12.2(14)SX |
|
1-port ATM E3 port adapter, enhanced |
12.2(14)SX |
PA-A3-OC3SMI PA-A3-T3 PA-A3-OC3SML PA-A3-E3 PA-A3-8T1IMA PA-A3-8E1IMA |
ATM with traffic shaping Note |
12.2(14)SX |
PA-T3+ PA-2T3 PA-2T3+ PA-E3 PA-2E3 PA-MC-T3 PA-MC-E3 PA-MC-2T3+ |
T3/E3 (clear-channel and channelized) |
12.2(14)SX |
PA-8T-V35 PA-8T-X21 PA-8T-232 PA-MC-2E1/120 PA-MC-8T1 PA-MC-8E1/120 PA-MC-2T1 PA-MC-4T1 |
T1/E1 |
12.2(14)SX |
PA-4E1G/120 |
T1/E1 |
12.2(17)SX |
|
Multichannel T1/E1 8PRI Note |
12.2(14)SX |
PA-2H |
HSSI |
12.2(14)SX |
|
Multichannel STM-1 |
12.2(14)SX |
Service Modules

Note•
For any service modules that runs its own software, see the service module software release notes for information about the minimum required service module software version.
•With SPAN configured to include a port-channel interface to support a service module, be aware of CSCth03423 and CSCsx46323.
•Application Control Engine (ACE) Module
•Wireless Services Module (WiSM)
•Application-Oriented Networking Module
•Traffic Anomaly Detector Module
•Wireless LAN Service Module (WLSM)
•Persistent Storage Device (PSD) Module
•Multi-Processor WAN Application Module (MWAM)
•Content Services Gateway (CSG) Module
•Communication Media Module (CMM)
•IPsec VPN Acceleration Services Module
•Content Switching Module with SSL (CSM-S)
•Content Switching Module (CSM)
•Intrusion Detection System Modules (IDSMs)
•Network Analysis Modules (NAMs)
•Secure Sockets Layer (SSL) Services Module
Application Control Engine (ACE) Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
ACE20-MOD-K9 |
5.23 A@42 V |
Application Control Engine (ACE) module |
|
With Supervisor Engine 720 |
12.2(18)SXF4 |
||
The ACE module runs its own software—See these publications: http://www.cisco.com/en/US/products/ps6906/tsd_products_support_model_home.html See the ACE software release notes for information about the minimum required ACE software version. |
|||
Note • • • |
Wireless Services Module (WiSM)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
6.07 A@42 V |
Wireless Services Module (WiSM) |
|
With Supervisor Engine 720 |
12.2(18)SXF2 |
||
WS-SVC-WISM-1-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/ps6526/tsd_products_support_model_home.html See the WS-SVC-WISM-1-K9 software release notes for information about the minimum required WS-SVC-WISM-1-K9 software version. |
|||
Note • • • • • |
Application-Oriented Networking Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
4.00 A@42 V |
Application-Oriented Networking (AON) Module |
|
With Supervisor Engine 720 |
12.2(18)SXE1 |
||
WS-SVC-AON-1-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/ps6480/prod_release_notes_list.html See the WS-SVC-AON-1-K9 software release notes for information about the minimum required WS-SVC-AON-1-K9 software version. |
|||
Note • • • |
WebVPN Services Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.94 A@42 V |
WebVPN Services Module |
|
With Supervisor Engine 720 |
12.2(18)SXE2 |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
WS-SVC-WEBVPN-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/hw/switches/ps708/prod_release_notes_list.html#anchor24 See the WS-SVC-WEBVPN-K software release notes for information about the minimum required WS-SVC-WEBVPN-K software version. |
|||
Note • • |
Anomaly Guard Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
4.00 A@42 V |
Anomaly Guard Module |
|
With Supervisor Engine 720 |
12.2(18)SXD3 |
||
With Supervisor Engine 2 |
12.2(18)SXD3 |
||
WS-SVC-AGM-1-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/ps6236/tsd_products_support_model_home.html See the WS-SVC-AGM-1-K9 software release notes for information about the minimum required WS-SVC-AGM-1-K9 software version. |
|||
Note • • • |
Traffic Anomaly Detector Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
4.00 A@42 V |
Traffic Anomaly Detector Module |
|
With Supervisor Engine 720 |
12.2(18)SXD3 |
||
With Supervisor Engine 2 |
12.2(18)SXD3 |
||
WS-SVC-ADM-1-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/ps6236/tsd_products_support_model_home.html See the WS-SVC-ADM-1-K9 software release notes for information about the minimum required WS-SVC-ADM-1-K9 software version. |
|||
Note • • • |
Wireless LAN Service Module (WLSM)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
3.10 A@42 V |
Wireless LAN service module |
|
With Supervisor Engine 720 |
12.2(18)SXD |
||
WS-SVC-WLAN-1-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/ps5865/tsd_products_support_eol_model_home.html See the WS-SVC-WLAN-1-K9 software release notes for information about the minimum required WS-SVC-WLAN-1-K9 software version. |
|||
Note • • • • |
Persistent Storage Device (PSD) Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
4.00 A@42 V |
Persistent Storage Device Module |
|
With Supervisor Engine 720 |
12.2(18)SXD1 |
||
With Supervisor Engine 32 |
12.2(18)SXF7 |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-SVC-PSD-1 runs its own software—See these publications: http://www.cisco.com/en/US/products/hw/switches/ps708/prod_release_notes_list.html#anchor21 See the WS-SVC-PSD-1 software release notes for information about the minimum required WS-SVC-PSD-1 software version. |
|||
Note • • |
Multi-Processor WAN Application Module (MWAM)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
3.57 A@42 V |
Multi-Processor WAN Application Module |
|
With Supervisor Engine 720 |
12.2(18)SXD1 |
||
With Supervisor Engine 32 |
12.2(18)SXF5 |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-SVC-MWAM-1 runs its own software—See these publications: http://www.cisco.com/en/US/docs/wireless/pdsn/12.28zb/mwan_install_config/mwamhwrn.html See the WS-SVC-MWAM-1 software release notes for information about the minimum required WS-SVC-MWAM-1 software version. |
|||
Note • • • |
Content Services Gateway (CSG) Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
3.00 A@42 V |
Content Services Gateway (CSG) Module |
|
With Supervisor Engine 720 |
12.2(18)SXD1 |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-SVC-CSG-1 runs its own software—See these publications: http://www.cisco.com/en/US/products/sw/wirelssw/ps779/tsd_products_support_series_home.html See the WS-SVC-CSG-1 software release notes for information about the minimum required WS-SVC-CSG-1 software version. |
|||
Note • • |
Communication Media Module (CMM)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
6.00 A@42 V |
Communication Media Module |
|
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-SVC-CMM runs its own software—See these publications: http://www.cisco.com/en/US/docs/interfaces_modules/services_modules/cmm/release/notes/OL_4847.html See the WS-SVC-CMM software release notes for information about the minimum required WS-SVC-CMM software version. |
|||
Note |
|||
|
|||
|
6-Port E1 Interface Port Adapter |
||
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
6-Port T1 Interface Port Adapter |
||
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
Adhoc Conferencing and Transcoding Port Adapter |
||
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
|
24-Port FXS Interface Port Adapter |
||
With Supervisor Engine 720 |
12.2(14)SX |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
IPsec VPN Acceleration Services Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
1.89 A@42 V |
IPsec VPN Acceleration Services Module |
|
With Supervisor Engine 720 |
12.2(17b)SXA |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-SVC-IPSEC-1 uses the Cisco IOS software that is running on the switch. |
|||
Note • • • • • • • • • |
Content Switching Module with SSL (CSM-S)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.15 A@42 V |
Content Switching Module with SSL (CSM-S) |
|
With Supervisor Engine 720 |
12.2(18)SXE |
||
With Supervisor Engine 2 |
12.2(18)SXD |
||
WS-X6066-SLB-S-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/hw/modules/ps2706/ps780/tsd_products_support_model_home.html See the WS-X6066-SLB-S-K9 software release notes for information about the minimum required WS-X6066-SLB-S-K9 software version. |
|||
Note • • • • • • |
Content Switching Module (CSM)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
3.00 A@42 V |
Content Switching Module |
|
With Supervisor Engine 720 |
12.2(14)SX1 |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-X6066-SLB-APC runs its own software—See these publications: http://www.cisco.com/en/US/products/hw/modules/ps2706/ps780/tsd_products_support_model_home.html See the WS-X6066-SLB-APC software release notes for information about the minimum required WS-X6066-SLB-APC software version. |
|||
Note • • • • • |
Firewall Services Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
4.09 A@42 V |
Firewall Services Module; CEF256 |
|
With Supervisor Engine 720 |
12.2(14)SX1 |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-SVC-FWM-1-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/hw/modules/ps2706/ps4452/tsd_products_support_model_home.html See the WS-SVC-FWM-1-K9 software release notes for information about the minimum required WS-SVC-FWM-1-K9 software version. |
|||
Note • • |
Intrusion Detection System Modules (IDSMs)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.50 A@42 V |
Intrusion Detection System Module 2; CEF256 |
|
With Supervisor Engine 720 |
12.2(14)SX1 |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-SVC-IDSM2-K9 runs its own software—See these publications: http://www.cisco.com/en/US/products/hw/modules/ps2706/ps5058/tsd_products_support_model_home.html See the WS-SVC-IDSM2-K9 software release notes for information about the minimum required WS-SVC-IDSM2-K9 software version. |
|||
Note • • |
Network Analysis Modules (NAMs)
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
3.47 A@42 V |
Network Analysis Module 2; CEF256 |
|
|
2.89 A@42 V |
Network Analysis Module 1; CEF256 |
|
With Supervisor Engine 720 |
12.2(14)SX1 |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
WS-SVC-NAM-2 and WS-SVC-NAM-1 run their own software—See this publication for more information: http://www.cisco.com/en/US/products/hw/modules/ps2706/ps5025/tsd_products_support_model_home.html See the WS-SVC-NAM-2 and WS-SVC-NAM-1 software release notes for information about the minimum required WS-SVC-NAM-2 and WS-SVC-NAM-1 software version. |
|||
Note • • • |
Secure Sockets Layer (SSL) Services Module
(append "=" for spares) |
Required |
|
|
---|---|---|---|
|
2.94 A@42 V |
Secure Sockets Layer (SSL) Services Module |
|
With Supervisor Engine 720 |
12.2(14)SX1 |
||
With Supervisor Engine 32 |
12.2(18)SXF |
||
With Supervisor Engine 2 |
12.2(17d)SXB |
||
Note • • • • • |
Fan Trays

Note•
Enter the show environment status | include fan command or the show environment cooling command to display information about the installed fan trays.
•To use a high-capacity fan tray with a Supervisor Engine 2, you must enter the hw-module fan-tray version 2 command and then remove and quickly reinsert the fan tray.
High-Capacity Fan Trays
These high-capacity fan trays support both all supervisor engines and require at least a 2,500 W power supply.
(append "=" for spares) |
Allocated at 42 V |
|
Software Version |
---|---|---|---|
|
1.37 A@42 V |
High-capacity fan tray for WS-C6503-E chassis |
12.2(14)SX |
Note |
|||
|
2.98 A@42 V |
12.2(14)SX |
|
|
4.29 A@42 V |
High-capacity fan tray for CISCO7606 chassis |
12.2(14)SX |
|
2.35 A@42 V |
High-capacity fan tray for WS-C6506-E chassis |
12.2(14)SX |
|
12 V fan |
High-capacity fan tray for WS-C6506 chassis |
12.2(14)SX |
|
5.75 A@42 V |
High-capacity fan tray for WS-C6509-NEB-A and CISCO7609 chassis |
12.2(14)SX |
|
5.75 A@42 V |
High-capacity fan tray for WS-C6509-V-E chassis |
12.2(18)SXF10 |
|
3.58 A@42 V |
High-capacity fan tray for WS-C6509-E chassis |
12.2(14)SX |
|
12 V fan |
High-capacity fan tray for WS-C6509 chassis |
12.2(14)SX |
|
7.10 A@42 V |
12.2(14)SX |
Standard-Capacity Fan Trays
These standard-capacity fan trays support only Supervisor Engine 2.
(append "=" for spares) |
Allocated at 42 V |
|
Software Version |
---|---|---|---|
|
None |
Standard-capacity fan tray for WS-C6503 and CISCO7603 chassis |
12.2(17d)SXB |
|
None |
Standard-capacity fan tray for CISCO7606 chassis |
12.2(17d)SXB |
|
12 V fan |
Standard-capacity fan tray for WS-C6506 chassis |
12.2(17d)SXB |
|
12 V fan |
Standard fan tray for WS-C6509-NEB chassis |
12.2(17d)SXB |
|
12 V fan |
Standard-capacity fan tray for WS-C6509 chassis |
12.2(17d)SXB |
|
12 V fan |
Standard-capacity fan tray for WS-C6513 and CISCO7613 chassis |
12.2(17d)SXB |
Power Supplies
•WS-C6504-E and CISCO7604 Power Supplies
•WS-C6503, WS-C6503-E, and CISCO7603 Power Supplies
CISCO7606 Power Supplies
(append "=" for spares) |
|
|
---|---|---|
|
2700 W AC power supply |
12.2(18)SXE |
|
2700 W DC power supply |
12.2(18)SXE |
WS-C6504-E and CISCO7604 Power Supplies
(append "=" for spares) |
|
|
---|---|---|
|
2700 W AC power supply |
12.2(18)SXE |
|
2700 W DC power supply |
12.2(18)SXE |
WS-C6503, WS-C6503-E, and CISCO7603 Power Supplies
All Other Power Supplies

Note The power supplies in this section are not supported in these chassis:
•Catalyst 6503
•Catalyst 6503-E
•CISCO7603
•Catalyst 6504-E
•CISCO7604
(append "=" for spares) |
|
|
---|---|---|
|
8,700 W AC power supply |
12.2(18)SXF8 |
Note • • • • • |
||
|
6,000 W DC power supply |
12.2(18)SXF13 |
Note • • |
||
|
6,000 W AC power supply |
12.2(18)SXD |
Note • • • |
||
|
4,000 W DC power supply |
12.2(14)SX |
|
4,000 W AC power supply |
12.2(14)SX |
|
3,000 W AC power supply |
12.2(17a)SX |
Note • • |
||
|
3,000 W AC power supply |
12.2(14)SX |
|
2,500 W AC power supply |
12.2(14)SX |
|
2,500 W DC power supply |
12.2(14)SX |
Chassis
13-Slot Chassis
(append "=" for spare) |
|
|
---|---|---|
|
Catalyst 6513-E chassis: • • • – – • – – – |
|
With Supervisor Engine 720 |
12.2(18)SXF14 |
|
With Supervisor Engine 32 |
12.2(18)SXF14 |
|
|
Catalyst 6513 chassis: • • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Cisco 7613 chassis: • • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
9-Slot Chassis
(append "=" for spare) |
|
|
---|---|---|
|
Catalyst 6509-V-E chassis: • • • • – – • |
|
With Supervisor Engine 720 |
12.2(18)SXF10 |
|
With Supervisor Engine 32 |
12.2(18)SXF10 |
|
|
Catalyst 6509-E chassis: • • – – Note • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Catalyst 6509 chassis: • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Catalyst 6509-NEB chassis • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Catalyst 6509-NEB chassis: • • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_16162.html |
|
With Supervisor Engine 720 |
12.2(17a)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Cisco 7609 chassis • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Cisco 7609 chassis: • • • http://www.cisco.com/en/US/docs/switches/lan/catalyst6500/hardware/Config_Notes/78_16162.html |
|
With Supervisor Engine 720 |
12.2(17a)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
6-Slot Chassis
(append "=" for spare) |
|
|
---|---|---|
|
Catalyst 6506-E chassis: • • – – Note • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Catalyst 6506 chassis: • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Cisco 7606 chassis: • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
4-Slot Chassis
3-Slot Chassis
(append "=" for spare) |
|
|
---|---|---|
|
• • • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Catalyst 6503 chassis: • • • • |
|
With Supervisor Engine 720 |
12.2(14)SX |
|
With Supervisor Engine 32 |
12.2(18)SXF |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
|
Cisco 7603 chassis: • • • • |
|
With Supervisor Engine 720: |
12.2(14)SX |
|
With Supervisor Engine 2 |
12.2(17d)SXB |
|
Note |
Unsupported Hardware
The following hardware is not supported:
•DWDM-SFP-5817—1000BASE-DWDM 1558.17 nm SFP (100-GHz ITU grid) SFP module
•DWDM-SFP-4692—1000BASE-DWDM 1546.92 nm SFP (100-GHz ITU grid) SFP module
•See the "Supervisor Engine 32 (CAT6000-SUP32/MSFC2A, 7600-SUP32/MSFC2A)" section for information about hardware that is not supported with the Supervisor Engine 32.
•With a Supervisor Engine 720, WS-X6516-GBIC hardware revisions 5.0 through 5.4 with a DFC3 installed.
Supervisor Engine 720 supports a DFC3 on these WS-X6516-GBIC hardware revisions:
–Lower than 5.0
–5.5 and higher
With a Supervisor Engine 720 and a DFC3 installed, WS-X6516-GBIC hardware revisions 5.0 through 5.3 do not power up. Without a DFC3, WS-X6516-GBIC hardware revisions 5.0 through 5.4 operate in bus mode.
See external field notice 24494 for more information:
http://www.cisco.com/en/US/ts/fn/200/fn24494.html
•These service modules:
–WS-X6381-IDS Intrusion Detection System (IDS) Module
–WS-X6380-NAM Network Analysis Module (NAM)
•Supervisor Engine 1 (WS-X6K-S1A-MSFC2, WS-X6K-SUP1A-MSFC)
•WS-X6624-FXS, WS-X6608-T1, and WS-X6608-E1 voice modules
•WS-X6101-OC12-MMF and WS-X6101-OC12-SMF ATM LANE modules
•WS-X6302-MSM Multilayer Switch Module
•Catalyst 6000 series chassis
•These power supplies cannot support high-capacity fan trays:
–WS-CAC-1300W
–WS-CDC-1300W
–WS-CAC-1000W
Unsupported modules remain powered down if detected and do not affect system behavior.