Release Notes for Cisco UCS C-Series Software, Release 1.4(5)
Overview of the Pre-Installed Cisco Flexible Flash Card
Hardware and Software Interoperability
Upgrading BIOS and CIMC Firmware
Issues Addressed in Release 1.4(5h)
Issues Addressed in Release 1.4(5e)
Issues Addressed in Release 1.4(5g)
Obtaining Documentation and Submitting a Service Request
First Published Date: 11 June 2012
This document describes the new features, system requirements, open caveats and known behaviors for C- series software release 1.4(5) including Cisco Integrated Management Controller software and any related BIOS, firmware, or drivers. Use this document in conjunction with the documents listed in the “Related Documentation” section.
Note We sometimes update the documentation after original publication. Therefore, you should also review the documentation on Cisco.com for any updates.
Table 1 shows the online change history for this document.
This section contains the following topics:
The Cisco UCS C220 M3 Rack Server is designed for performance and density over a wide range of business workloads, from web serving to distributed databases. The enterprise-class Cisco UCS C220 M3 server extends the capabilities of the Cisco UCS portfolio in a 1RU form factor with the addition of the Intel® Xeon® processor E5-2600 product family. In addition, the Cisco UCS C220 M3 server offers up to two Intel® Xeon® processor E5-2600s, 16 DIMM slots, eight disk drives, and two 1 Gigabit Ethernet LAN-on-motherboard (LOM) ports.
The Cisco UCS C240 M3 Rack Server is designed for both performance and expandability over a wide range of storage-intensive infrastructure workloads, from big data to collaboration. The enterprise-class Cisco UCS C240 M3 server further extends the capabilities of the Cisco UCS portfolio in a 2RU form factor with the addition of the Intel® Xeon® processor E5-2600 product family. The Cisco UCS C240 M3 offers up to two Intel® Xeon® processor E5-2600 product family, 24 DIMM slots, 24 disk drives, and four 1 Gigabit Ethernet LOM ports.
The Cisco UCS C220 M3 and the Cisco UCS C240 M3 interfaces with Cisco UCS using the Cisco UCS P81E Virtual Interface Card (VIC). The Cisco UCS P81E VIC is a virtualization-optimized Fibre Channel over Ethernet (FCoE) PCI Express (PCIe) 2.0 x8 10-Gbps adapter designed for use with Cisco UCS C-Series servers. The VIC is a dual-port 10 Gigabit Ethernet PCIe adapter that can support up to 18 PCIe standards-compliant virtual interfaces, which can be dynamically configured so that both their interface types—network interface card (NIC) or host bus adapter (HBA) and identity (MAC address and worldwide name (WWN))—are established using just-in-time provisioning. In addition, the Cisco UCS P81E can support network interface virtualization and Cisco® Data Center Virtual Machine Fabric Extender (VM-FEX) technology.
The Cisco Flexible Flash card is pre-installed with three software bundles, each on one of four preconfigured virtual drives (VDs). The fourth VD allows you to install an OS or an embedded hypervisor.
The VDs are configured with the following content:
Refer to the following documents for more information about these tasks:
The links to these documents are in the C-Series documentation road map:
For detailed information about storage switch, operating system, adapter, adapter utility, and storage array interoperability, see the Hardware and Software Interoperability Matrix for your release located at:
http://www.cisco.com/en/US/products/ps10477/prod_technical_reference_list.html
The Cisco UCS C-Series servers supports a wide variety of 10 Gigabit Ethernet connectivity options using Cisco 10GBASE SFP+ modules.
Table 2 and Table 3 details the controllers and the supported transceivers.
The C-Series software release 1.4(5) includes the following software files:
Note Always upgrade both the BIOS and the CIMC from the HUU ISO. Do not upgrade individual components (only BIOS or only CIMC), since this could lead to unexpected behavior.
The Cisco Host Upgrade Utility (HUU) is a tool that upgrades the following firmware:
– Intel Ethernet i350 PCI Server Adapter
– 5709 Dual and Quad port adapters
The image file for the firmware is embedded in the ISO. The utility displays a menu that allows you to choose which firmware components to upgrade. For more information on this utility see:
http://www.cisco.com/en/US/products/ps10493/products_user_guide_list.html
Starting with this 1.4 release, separate ISO images of Host Upgrade Utility are available for different server platforms.
The ISO image is now named as ucs-<server_platform>-huu-<version_number>.iso.
The Cisco Host Upgrade Utility contains the following files:
The management client must meet or exceed the following minimum system requirements:
Use the Host Upgrade Utility to upgrade the C-Series firmware. Host Upgrade Utility can upgrade the following software components:
All firmware should be upgraded together to ensure proper operation of your server.
Cisco provides the Cisco Host Upgrade Utility to assist you in upgrading the BIOS, CIMC, LOM, LSI storage controller, and Cisco UCS P81E Virtual Interface Card firmware to compatible levels.
The correct and compatible firmware levels for your server model are embedded in the utility ISO.
To use this utility, use the Cisco Host Upgrade Utility User Guide which includes the instructions for downloading and using the utility ISO. Select the guide from this URL:
http://www.cisco.com/en/US/products/ps10493/products_user_guide_list.html
This section contains the following topics:
The BIOS image with this release contains the Microcode Update which fixes the Intel VT FlexPriority Errata which is documented in the Intel Public Spec Update for Aug 2013. This errata impacts all Cisco UCS C-series servers.
The following software features are supported in the Release 1.4(5):
Note These commands should only be used under the direction of Cisco TAC.
For more information about the commands, refer to the Cisco UCS C-Series Servers Integrated Management Controller CLI Command Reference, Release 1.4.
– Cisco UCS C-Series Servers Integrated Management Controller CLI Command Reference, Release 1.4
– Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide, Release 1.4
The supported MIB definition for release 1.4(5) can be found at the following link: ftp://ftp.cisco.com/pub/mibs/supportlists/ucs/ucs-C-supportlist.html
Note The above link is incompatible with IE 9.0.
This section contains the following topics:
The C240 cooling algorithm has been modified in Release 1.4(5h) to prevent the excessive heating of some PCIe adapters at the system idle state
Release 1.4(5e) addresses the issue of the server resetting while loading to the operating system with E5-2643 CPU.
Release 1.4(5g) covers the following issues:
This section contains the following topics:
Symptom An idle C240 system with LSI cards may show higher card temperatures.
Symptom LSI cards on C220-M3 servers get overheated when the system is idle.
Symptom During system power on or reboot, HDD critical events are generated in the SEL.
Workaround This is not really a critical event. The HDD critical event is harmless and does not indicate an actual HDD fault. When the system boots to OS, the same HDD which reported critical becomes normal. This is also applicable to the LSI applications. The SEL should show that the HDD which displayed the critical events goes back to normal after 30-60 seconds.(CSCtz96990)
Symptom HDD critical event occurs in the CIMC SEL during the RAID rebuild in progress.
Symptom In C240 3.5 server and C240 2.5 server with 24 HDDs, when you enable the locate HDD LED option through the Web BIOS or through the CIMC Storage Inventory page of the 9266-8i card, HDD drive fault assert critical event followed by deassert normal event in SEL is observed.
Workaround Ignore the following alert:
This alert will be followed by the deassert event that is generated during the HDD LED process. (CSCtz32109)
Symptom When the system is restarted, the BIOS POST hangs with the CATERR SEL event. The BIOS POST hangs at the "Configuring platform hardware..." screen.
Workaround This issue is resolved. The Peripheral Component Interconnect Express (PCIe) completion timeout is increased to resolve this issue. (CSCtz96190)
Symptom C220 M3 and C240 M3 rack servers populated with the LSI 9266-8i MegaRAID adapter may hang intermittently during BIOS POST and CATERR is reported in the SEL logs.
Workaround To recover from this condition, users will need to reboot the system. (CSCua24918)
Symptom Cisco UCS C220 and UCS C240 servers displays errors when the Power Restore Policy is set to restore-state and an AC power cycle is performed with the host power is ON.
Workaround Set the Power Restore Policy to On with fixed or random delay.(CSCty42040)
Symptom When using two PSUs, the host does not reboot or shut down but PSU redundancy events would be seen. But, if both PSUs are faulty, the host will reboot continuously or shutdown.
Symptom Product ID information is not displayed in Web GUI for PSUs.
Symptom When running the KVM Viewer client on a 64 bit Linux OS, block devices such as a USB stick or floppy drive will have the read only box checked when you open the vMedia tab. Trying to uncheck the read only box will fail, and devices can only be mapped as read only.
Workaround Use a 32 bit Linux OS or Windows OS for the client system running the KVM Viewer application.(CSCty37812)
Symptom When using the KVM Viewer client application with a 64 bit Linux OS, mapping both floppy disk and removable disk at the same time will cause improper functioning of the application that is, the drive data is invalid and/or cannot be read. Even mapping only a single drive (floppy or removable disk) at a time can yield unexpected failures. For example, after mapping and unmapping a USB stick, click on the exit button of the vMedia tab and reopen the vMedia tab. Now, if you try map the device again the vMedia tab will crash and all the mapped devices will be unmapped.
Note Mapping of CD-ROM drives and image files works properly, this problem is observed only when mapping physical Linux block devices such as /dev/sdX.
Workaround Perform the following steps to map physical block devices:
Step 1 Map only a single physical block device at a time (not both floppy and removable device at a time). This will usually work, but may have occasional unexpected failures. Restart the client if the vMedia tab stops functioning.
Step 2 Generate an.img file of the block device contents and map this instead, this has no known issues.
Step 3 Use a 32 bit Linux OS / Windows OS / Mac OS client system to run the KVM Viewer/vMedia application.(CSCty42187)
Symptom The KVM viewer version does not display the FCS version, that is, 2.0.0.27. This means the client machine has not downloaded the new.jar file for the KVM/vMedia client and the old client is getting executed. This issue is seen when you use KVM with the old CIMC firmware and then upgraded the CIMC. To check the KVM viewer version, invoke KVM and go to Help >About KVM Viewer. The KVM Viewer version should be 2.0.0.27 for Release 1.4(4a).
Workaround To resolve this issue delete the Java temporary cached files and invoke KVM from CIMC GUI. The Java Control Panel app (javacpl.exe) is in the bin directory of the Java JRE installation.
For Windows, go to in c:\Program Files\Java\<JRE VERSION>\bin and delete the cached Cisco Virtual KVM Console application and re-launch remote presence.
For Linux, go to the Java directory, for example./usr/java/jre1.6.0_26/bin/ControlPanel.(CSCtx88477)
Symptom KVM does not respond to keyboard input after HUU is updated.
Workaround Connect the physical keyboard to the server and press Enter or any other key.(CSCty34492)
Symptom After you reboot or upgrade CIMC firmware through the Web GUI, you are redirected to the login page. When you try to login, the following message is displayed:
Even after you log out and log in, this message is still displayed.
Workaround Clear the cookies and cache. You should be able to login successfully. (CSCts39518)
Symptom Patrol scrub is disabled when a channel is disabled due to a bad DIMM.
Workaround Replace the bad DIMM. (CSCtx58908)
Symptom When Option ROM run out of space, the POST error 0xA6A0 displays as a critical event.
Workaround In the BIOS setup, disable the Option ROM for adapters for which the Preboot eXecution Environment support is not required.(CSCtx68045)
Symptom The system hangs when you press Control + H. This issue is observed with both the mezzanine card and the 9266 adapter and occurs intermittently but some systems display a high fail rate.
Workaround Perform the following steps:
Step 2 Load the EFI shell and run the drvcfg -s command.
The Web BIOS gets invoked.(CSCty15505)
Symptom The Web BIOS does not respond to mouse clicks.
Workaround Press any key on the keyboard.(CSCtw53469)
Symptom When the EIST option is disabled in BIOS, the system boots to OS at CPU frequency 1.2 GHz.
Workaround This issue is resolved. When the EIST option disabled in BIOS, the system boots to OS at CPU maximum non-turbo frequency. (CSCtu29214)
Symptom Installing ESX/ESXi 4.1 U2 on C220 and C240 servers displays the following error on console:
Workaround Refer to the VMWare Knowledge Base page at VMWare KB.(CSCtw86205)
This section includes the following topics:
Symptom During high or medium Serial Over LAN (SOL) traffic, the Intelligent Platform Management Interface (IPMI) LAN interfaces becomes unresponsive.
Workaround Do not use IPMI queries during high SOL traffic.
Symptom The Boot Loader version displays extra characters after the CIMC version.
Workaround This is a new feature and displays the U-Boot version.
Symptom The system hangs at preboot disk detection screen if only SAS drives are present and the system has no SKUROM.
Workaround Remove SAS drives and replace with SATA drives and reboot system.
Symptom The Power Saving and the Performance Modes displays the same 1.5V with 3DPC.
Workaround None. This is an expected behavior of the Intel memory PORT.
Symptom The LSI SWRAID OPROM does not get dispatched and a A6A0 warning is displayed in the SEL.
Workaround Disable the unused device’s legacy OPROMs through the BIOS setup or using the Configure BIOS in CIMC.
Symptom PCI bus and device number for some of the devices change after upgrading the C220 and C240 servers from 1.4(4c) to later software releases.
Workaround None. Reconfigure your OS and applications which depend on fixed PCI bus and device numbers. (CSCud22651)
Symptom vMedia disconnects when you try to boot CentOS-6.1 LiveCD.
Symptom All the onboard LOM port OPROMMs do not get executed during the booting process in C240 server models.
Workaround Restart the system.
Symptom Pressing the Esc key while the LOM option ROM is getting executed causes the rest of the option ROMs to be skipped.
Symptom OVM3.0 can not discover iSCSI target during installation.
Symptom When KVM is launched, a "Login Failed" error displays and KVM closes.
Workaround Wait for 2-3 minutes and relaunch KVM.
Symptom The Network mode cannot be set to cisco_card mode even though the option is available.
Workaround Install the Cisco UCS P81E card to move into the cisco_card network mode.
Symptom In Power Restore Policy, a delay value displays when the delay type is set to random.
Workaround Ignore the displayed value.
Symptom When you create a image of file or folder size bigger than 4 GB using vMedia Create image feature, the following message displays:
Workaround Use files or folders with smaller sizes.
Symptom If you try to use vMedia to map both an.img file and a physical USB stick (pen/thumb drive) simultaneously, the following message (or a similar one) displays:
Workaround Map one drive at a time.
Symptom KVM and vMedia do not work with mismatched IE and JRE executables.
Workaround Ensure JRE matches the IE version.
Symptom The mouse does not work or track in the LSI Web BIOS tool.
Workaround Use one of the following workarounds:
Symptom BIOS update fails if KVM is launched while BIOS is uploading.
Workaround Use one of the following workarounds:
Symptom When you launch KVM in IE, the following message displays:
Workaround Perform the following steps:
Step 1 In the IE, select Tools > Internet Options.
The Internet Options dialog will pop up.
Step 2 Click the Advanced tab.
Step 3 Uncheck the Do not save encrypted pages to disk option.
Symptom If you disable both SSH and HTTP, connectivity to CIMC is lost.
Workaround If disabled, reset CIMC to factory default using the F8 utility during POST.
Symptom CIMC Web GUI does not display after the certificate import process and the browser displays the following message:
Workaround During the certificate import process, provide different values for the Subject Information and Issuer Information fields.
Symptom In IE, when network mode is changed to cisco_card mode, a “Unable to parse xml” message displays.
Symptom The Power Saving and Performance modes displays the same 1.5V with 3DPC.
Workaround None. This is an expected behavior.
Symptom While upgrading from the beta version to the FCS version, the system gets stuck at different points in the POST screen, usually at the initial video screens, before the options can be executed.
This section includes the following topics:
Symptom The HDD faults are not logged in the CIMC SEL for UCSC-C240-M3S.
Workaround You can observe the HDD fault status under Storage Inventory in the CIMC. (CSCua51097)
Symptom When you run the update-all command immediately after the BIOS update, the chassis component firmware update process fails.
Workaround Perform the CIMC reboot if the update-all command fails after the BIOS update. (CSCua49441)
Symptom If the update-all command, to update the chassis components firmware, is run when the CIMC or the BIOS update is already in progress, the following messsage appears:
This is an expected behavior but if the update-all command is run again, the following incorrect message is displayed:
If you now run the show command, another incorrect message is displayed:
Workaround After all the BIOS and CIMC updates are complete, do the following:
Step 1 In the CIMC Web GUI, go to WebGUI -> Admin-> Utilities.
Step 2 Click Reboot CIMC to reboot the CIMC.
Step 3 Run the update-all command. (CSCua49421)
Symptom When KVM is launched, a "Connection failed" error displays and the KVM window does not open.
Step 1 In the CIMC Web GUI, go to WebGUI -> Admin -> Utilities.
Step 2 Click Reboot CIMC to reboot the CIMC. (CSCua06392)
Symptom Sometimes the Update-all command returns inconsistent messages causing the chassis components firmware to fail.
Workaround Use the following commands in the chassis/firmware scope and read the messages or warnings displayed.
Server/chassis/firmware# show detail
Server/chassis/firmware# update-all
If any errors or failures are encountered, reboot the CIMC and retry the update-all command. (CSCua41121)
Symptom CIMC recognizes only the SuperCap and all other information like the charge and charging state is not available.
Symptom The CIMC Web GUI displays the battery status as "unknown" when LSI 9265CV-8i with supercap battery is used.
Workaround Use MegaCLI or LSI Web BIOS to read the battery status. (CSCty64241)
Symptom The duration counter fails to start after the images are mapped over vMedia.
Workaround Perform the following workaround:
Step 1 Click Exit in the Virtual Media tab to exit.
Step 2 Login again by clicking the Virtual Media tab.
Step 3 Remap the ISO by adding the image or.iso again. (CSCtw80358)
Symptom The HDD presence cannot be viewed through SNMP.
Workaround Use either alternate interfaces or do snmp query again for the HDD inventory after the action. (CSCty60975)
Symptom CIMC Web GUI does not reflect the "Reconstruction" virtual disk state after expanding the virtual disk.
Workaround Use the same interface that you used for configuring the virtual disk to view the “Reconstruction” state. The interface can either be Web GUI or MegaCLI.(CSCtx96912)
Symptom When 200GB or 300GB INTEL SSD is installed, the Description and the PID fields display UNKNOWN.
Symptom The PID displays UNKNOWN for Cisco UCSC RAID SAS 2008M-8i Mezzanine card (RAID 0,1,10).
Symptom The PID field displays UNKNOWN for Seagate ST32000444SS or ST3300656SS or ST31000640SS.
Symptom The PID field displays UNKNOWN for Broadcom 57712-T 10 Gbps 2 port NIC.
Symptom The PID field displays UNKNOWN for Emulex OCe11102-FX or Qlogic QLE8242-CU.
Symptom The CPU PID field displays UNKNOWN for UCS-CPU-E5-2660.
Symptom The SEL event is not logged in the OS Watchdog timer expiration.
Symptom PID shows wrong value for MegaRAID 9266CV-8i w/FTM + LSI CacheVault.
Symptom Broadcom 5709 Dual Port 10/100/1Gb NIC w/TOE iSCSI shows wrong PID.
Symptom For a 450W power supply, the PXUx_VOUT reading shows 1V when the actual reading is about 11V.
Symptom C220 M3 and C240 M3 rack servers populated with the LSI 9266-8i MegaRAID adapter may hang intermittently during BIOS POST and CATERR is reported in the SEL logs.
Workaround To recover from this condition, users will need to reboot the system. (CSCua24918)
Symptom Repeated and multiple drive removal and insertion may result in the LSI SWRAID OPROM getting into an inconsistent state and not being able to detect the plugged in or removed drives. Rebooting the system does not fix this issue and the drive states could change from Online to Ready resulting in loss of data.
Workaround You need to insert or remove the drives one at a time and wait for the LSI SWRAID OPROM to detect the drive event (either removal or insertion) via a message. Press Esc and then insert or remove another drive.(CSCtz68178)
Symptom The Storage Controller name in Device Manager, under Windows 2008 R2 SP1 for C240 server, displays the Server model number as C220 instead of C240.
Symptom The 2008-8i MEZZ Card Serial number and FRU information is missing in the LSI Web BIOS and the LSI Host Application such as MSM and MegaCli.
Symptom When I/O is running on two or more hard disks part of a RAID Array, the Activity LED is seen blinking green on the hard disks on which the I/O is running and is part of the RAID array and also on the adjacent hard disk which is not part of the RAID group.
Workaround Ignore the activity LED running on the adjacent hard disk as there is no actual I/O running on this hard disk. (CSCtz13588)
Symptom The drive rebuild process does not complete if the system is being rebooted during the rebuild operation.
Workaround Allow the rebuild process to complete, that is, till it reaches 100% before rebooting the server.(CSCty92714)
Symptom The system hangs in the pre-boot drive detection screen and displays the "Missing Drive" message.
Workaround This occurs when there is a bad drive in the system. If you do not know which drive needs to be replaced, remove all the drives except one. Enter ctrl-M, hot-plug each drive and resolve. (CSCty78862)
Symptom The server hangs during BIOS POST when scanning LSI devices.
Workaround When the system hangs, switch off the system and remove the failed drive. This would be the drive that has solid amber for the Status LED. The Status LED is the uppermost LED on the hard disk. After removing this drive, switch on the system. The system should now boot successfully. Replace the failed drive with a new drive. (CSCtx62350)
Symptom The USB Floppy Disk Drive (FDD) does not boot when it is mounted on the KVM console.
Workaround This issue is observed when the USB FDD is connected through vMedia. Connect the USB FDD directly to the server to resolve this issue.(CSCtz85749)
Symptom When different SKU of Sandybridge, like E5-2640, E5-2660 are populated on the system, the system does not switch on.
Workaround Use identical SNB SKU.(CSCtz25795)
Symptom When BIOS is upgraded from FCS BIOS version 1-4-4c-0 to MR4 BIOS, the Cisco virtual FDD/HDD 1.22 boot option does not appear in the setup page during the first booting session.
Workaround There is no functional impact. The Cisco virtual FDD/HDD 1.22 option appears on the USB page and in the installation. Subsequent reboot will make it appear on the boot option setup page. (CSCua07001)
Symptom Continuous beep sound is heard when the system is switched.
Workaround Do not switch on the CIMC and the host simultaneously. Switch on the host 3 minutes after switching on the power supply.(CSCtz11862)
Symptom BIOS setup changes does not get reflected in the CIMC.
Workaround Change the memory configuration manually to the Maximum Performance mode in the CIMC.(CSCtz63644)
Symptom The LED sensor color is red or amber or blue (or any supported color) even though the LED state is set to OFF.
Workaround Ignore the LED color when the LED state is set to OFF.(CSCth84883)
Symptom SNMPv1 traps are sent when SNMPv2 and SNMPv3 traps are enabled.
Symptom The AES encryption field does not show the encryption level (128, 256, and so on) on the Web GUI and CLI.
Workaround The SNMP V3 encryption key length must be clearly indicated. The SNMP agent supports AES - 128 bit encryption by default. (CSCtr31577)
Symptom The SNMPv3 traps are not received in the Net-SNMP receiver.
Symptom The power supply serial number is unavailable in the SNMP inventory because the Power Management Bus (PMBus) has not provided the power information.
Symptom The SNMPv3 walk, with AES encryption enabled, produces a “Decryption Error” when an SNMPv3 trap is triggered by an event. An “authentication failure” error is also encountered on triggering an event with the secure hash algorithm (SHA) authentication. The SHA trap error is encountered with both “authpriv” and “authnopriv” settings. The issue is observed till the master agent is restarted by clicking Save All in the CIMC Web UI SNMP configuration page.
Workaround Use the Message-Digest algorithm 5 (MD5) authentication and DES encryption for v3 user configuration. (CSCtx11173)
Symptom The KVM screen displays a blank screen.
Workaround Use the physical monitor to change the screen resolution. The following resolutions are supported:
Symptom Printing from Web GUI does work from Internet Exploder, but not Firefox.
Symptom When the LSI MegaRAID controller is used with the Cisco Flex Flash, SNMP_Inv_HDD:Disk_IDD N and RN shows 0,0,0 instead of 0,1,2 sequence.
Workaround Use the CIMC Web GUI to query the hard drive inventory.(CSCty26155)
Symptom When the LSI MegaRAID controller is used in conjunction with Cisco Flex Flash card, the SNMP_Inv_HDD:DiskPresence displays missing(11) instead of equipped(10).
Workaround Use the CIMC Web GUI to query the hard drive inventory.(CSCty26198)
Symptom When mapping a removal media using Mac Client, the USB device only supports Read-Only mode.
Workaround Use Windows client or Linux 32 bit client.(CSCty32452)
Symptom After upgrading MegaRAID firmware, sometimes the storage information in the CIMC Web GUI and CLI will be empty.
Workaround Restart the CIMC to get the storage information to be populated in CIMC Web GUI and CLI.(CSCtx08443)
Symptom Occasionally, when BIOS starts, the following message is displayed:
Workaround This message can be ignored.(CSCtx27907)
Symptom Occasionally when CIMC boots, the HTTP Web UI will not start.
Symptom OS installation hangs when installing from Unified Extensible Firmware Interface (UEFI) environment.
Workaround EFI OS is currently not supported.(CSCtw78721)
Symptom When a bad DIMM (which fails memory initialization) is present in one of the DIMM slots, BIOS may map out the other DIMMs in the same channel as the bad DIMM.
Workaround Remove or replace the bad DIMM.(CSCtx85587)
Symptom When Broadcom 5709 Gigabit Ethernet adapter is plugged into one of the PCIE slots, the server gets stuck at the BIOS post screen during the booting process.
Workaround Upgrade the firmware on the Broadcom 5709 Gigabit Ethernet adapter to version 5.2.7 or later.(CSCtx92042)
Symptom When the secondary iSCSI port is configured, booting from the iSCSI target results in kernel panic.
Symptom When LSI controller is downgraded, you may view the information, for example, virtual drive, firmware, of the previous version of the LSI controller in the CIMC Web GUI and CLI.
Workaround Restart the host machine so that the correct information is propagated to the CIMC Web GUI and CLI.(CSCtx08449)
Symptom PSU Failure events are seen after AC Power cycling the system.
Workaround Ignore the PSU failure events seen in SEL immediately after the AC power cycle.(CSCty38769)
Symptom Booting from SAN fails with UCS P81E on ESXi 4.1U2 and ESXi 5.0 and a fatal error is seen during installation.
Workaround This issue can be resolved with an asynch FNIC driver version. The custom ISO integrated with the Cisco FNIC driver, for ESXi 4.1 U2 and ESXi 5.0, is available at www.vmware.com.(CSCtx25927)
For configuration information for this release, please refer to the following:
The following related documentation is available for the Cisco Unified Computing System:
Refer to the release notes for Cisco UCS Manager software and the Cisco UCS C Series Server Integration with Cisco UCS Manager Guide at the following locations:
For information on obtaining documentation, submitting a service request, and gathering additional information, see What’s New in Cisco Product Documentation at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html.
Subscribe to What’s New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation, as an RSS feed and deliver content directly to your desktop using a reader application. The RSS feeds are a free service.