The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This document specifies the physical layer interface that exists between a DTE such as a high speed router or similar data device and a DCE such as a DS3 (44.736 Mbps) or SONET STS-1 (51.84 Mbps) DSU.
There are no specific requirements for this document.
This document is not restricted to specific software and hardware versions.
Refer to Cisco Technical Tips Conventions for more information on document conventions.
cisco Systems, Incorporated and T3plus Networking, Incorporated make no representation in respect to and does not warrant any of the information in the Specification, but furnishes such in good faith and to the best of its knowledge and ability. Without restricting the generality of the foregoing, cisco Systems and T3plus Networking make no representations or warranties as to fitness for a particular purpose, or as to whether or not the use of the information in the Specification may infringe any patent or other rights of any person. The recipient waives any claims it may have against cisco Systems or T3plus Networking in respect of any use which the recipient makes of the information or products derived therefrom.
Permission is granted to reproduce and distribute this specification provided:
cisco Systems, Inc. and T3plus Networking, Inc. names appear as authors,
a copy of this notice appears on all copies,
the contents of this document are not altered or modified.
The contents of this document may not be altered or modified without the express written permission of cisco Systems and T3plus Networking. It is intended that this document will serve as a high speed serial interface Specification and evolve into an industry standard. With this intent, it is expected that this Specification may be revised in the future to reflect additional requirements or adherence to domestic or international standards as they evolve. cisco Systems and T3plus Networking reserve the right to alter or modify this Specification or the equipment it relates to at any time without notice and without liability.
John T. Chapman cisco Systems, Inc. jchapman@cisco.com 1525 O'Brien Drive TEL: (415) 688-7651 Menlo Park, Ca 94025
Mitri Halabi T3plus Networking, Inc. mitri@t3plus.com 2840 San Tomas Expressway TEL: (408) 727-4545 Santa Clara, Ca, 95051 FAX: (408) 727-5151
To receive updated copies of this specification, it is advisable to request that you are added to the HSSI Specification mailing list of either cisco Systems or T3plus Networking.
This is a set of 3 addenda to the HSSI specification to document additions and clarifications to the HSSI specification since the 2.11 release and to enhance the operating and diagnostic capabilities for the Data Circuit-Terminating Equipment (DCEs) and Data Service Units (DSUs).
Delete all references to "clock must be maintained for n cycles after the last valid data." This is consistent with HSSI being a layer 1 specification, and therefore having no knowledge of data validity.
Replace with the following phrasing:
"To facilitate various bit/byte/frame DCE multiplexor implementations, the clock may be gapped to allow the deletion of framing pulses and to allow bandwidth limiting of the HSSI.
The maximum gapping interval is not specified. However, the clock sources ST and RT are expected to be generally continuous when both TA and CA are asserted. A gapping interval is measured as the amount of time between two consecutive clock edges of the same slope.
The instantaneous data transfer rate must never exceed 52 Mbps."
1.5 kohm resistors are to be used instead of 10 kohm resistor for pullup and pull down functions on all receivers. This allows the proper 150 mvolts minimum to be developed across the 110 ohms terminating resistors.
An optional signal, LC, has been added from the DCE to the Data Terminal Equipment (DTE) on the reserved signal pair pins 5 (+) & 30 (-). LC is a loopback request signal from the DCE to DTE, to request that the DTE provide a loopback path to the DCE. More specifically, the DTE would set TT=RT and SD=RD. ST would not be used, and could not be relied upon as a valid clock source under these circumstances.
This would then allow the DCE/DSU network management diagnostics to test the DCE/DTE interface independent of the DTE. This follows the HSSI philosophy that both the DCE and the DTE are intelligent independent peers, and that the DCE is capable of and responsible for maintaining its own data communications channel.
In the event that both the DTE and DCE asserted loopback requests, the DTE will be given preference.
This document specifies the physical layer interface that exists between a DTE such as a high speed router or similar data device and a DCE such as a DS3 (44.736 Mbps) or SONET STS-1 (51.84 Mbps) DSU. Future extensions to this specification may include support for rates up to SONET STS-3 (155.52 Mbps).
Section 1 introduces HSSI and relates it to other specifications. Section 2 contains a list of the terms and definitions used in this specification. Section 3 defines the electrical specifications, including signal names, definitions, characteristics, operation, and timing. Section 4 describes the physical properties including connector types, cable types, and pin assignments. Appendix A graphically relates timing relationships. Appendix B graphically defines polarity conventions. Appendix C has a detailed analysis of ECL noise immunity.
With respect to the ANSI/EIA series of standards, EIA-232-D, EIA-422-A, EIA-423-A, EIA-449, and EIA-530, this specification is distinct in that it:
supports serial bit rates up to 52 Mbps
uses Emitter Coupled Logic (ECL) transmission levels
allows the timing signals to be gapped, i.e., discontinuous
uses a simplified control signal protocol
uses a more detailed loopback signal protocol
uses a different connector
This specification adheres to the following definitions:
Analog Loopback:
A loopback in either direction that is associated with the line side of a DCE.
Assertion:
The (+side) of a given signal will be at potential Voh while the (-side) of the same signal will be at potential Vol. (ref: section 3.2 and Appendix B)
Deassertion:
The (+side) of a given signal will be at potential Vol while the (-side) of the same signal will be at potential Voh.
Data Communications Channel:
The transmission media and intervening equipment involved in the transfer of information between DCEs. In this specification, the data communications channel is assumed to be full duplex.
DCE:
Data Communications Equipment. The devices and connections of a communications network which connect the data communications channel with the end device (DTE). This will be used to describe the CSU/DSU.
Digital Loopback:
A loopback in either direction that is associated with the DTE port of a DCE.
DS3:
Digital Signal level 3. Also known as T3. Equivalent in bandwidth to 28 T1's. The bit rate is 44.736 Mbps.
DSU:
Data Service Unit. Provides a DTE with access to digital telecommunications facilitites.
DTE:
Data Terminal Equipment. The part of a data station that serves as a data source, destination, or both and that provides for the data communications control function according to protocols. This will be used to describe a router or similar device.
Gapped Clock:
A clock stream at a nominal bit rate which may be missing clock pulses at arbitrary intervals for arbitrary lengths of time.
OC-N:
The optical signal that results from an optical conversion of an STS-N signal.
SONET:
Synchronous Optical NETwork. An ANSI/CCITT standard for standardizing the use of optical communication systems.
STS-N:
Synchronous Transport Signal level n, where n = 1,3,9,12,18,24,36,48. STS-1 is the basic logical building block signal for SONET with a rate of 51.84 Mbps. STS-N are obtained by byte interleaving N STS-1 signals together with a rate of N times 51.84 Mbps.
+-------+ +-------+ | |<------ RT -------| | | |<------ RD -------| | | | | | | |<------ ST -------| | | |------- TT ------>| | | |------- SD ------>| | | DTE | | DCE | | |------- TA ------>| | | |<------ CA -------| | | |------- LA ------>| | | |------- LB ------>| | | | | | | |------- SG -------| | | X------- SH -------X | +-------+ +-------+
RT: Receive Timing
Direction: from DCE
RT is a gapped clock with a maximum bit rate of 52 Mbps, and provides receive signal element timing information for RD.
RD: Receive Data
Direction: from DCE
The data signals generated by the DCE, in response to data channel line signals received from a remote data station, are transferred on this circuit to the DTE. RD is synchronous with RT.
ST: Send Timing
Direction: from DCE
ST is a gapped clock with a maximum bit rate of 52 Mbps, and provides transmit signal element timing information to the DTE.
TT: Terminal Timing
Direction: to DCE
TT provides transmit signal element timing information to the DCE. TT is the ST signal echoed back to the DCE by the DTE. TT should be buffered by the DTE only, and not gated with any other signal.
SD: Send Data
Direction: to DCE
The data signals originated by the DTE, to be transmitted via the data channel to a far end data station. SD is synchronous with TT.
TA: data Terminal equipment Available
Direction: to DCE
TA will be asserted by the DTE, independently of CA, when the DTE is prepared to both send and receive data to and from the DCE. Data transmission should not commence until CA has also been asserted by the DCE.
If the data communications channel requires a keep alive data pattern when the DTE is disconnected, then the DCE shall supply this pattern while TA is deasserted.
CA: data Communications equipment Available
Direction: from DCE
CA will be asserted by the DCE, independently of TA, when the DCE is prepared to both send and receive data to and from the DTE. This indicates that the DCE has obtained a valid data communications channel. Data transmission should not commence until TA has also been asserted by the DTE.
LA: Loopback circuit A
LB: Loopback circuit B
Direction: to DCE
LA and LB are asserted by the DTE to cause the DCE and its associated data communications channel to provide one of three diagnostic loopback modes. Specifically,
LB = 0, LA = 0: no loopback
LB = 1, LA = 1: local DTE loopback
LB = 0, LA = 1: local line loopback
LB = 1, LA = 0: remote line loopback
A 1 represents assertion, and a 0 represents deassertion.
A local DTE (digital) loopback occurs at the DTE port of the DCE and is used to test the link between the DTE and DCE. A local line (analog) loopback occurs at the line side port of the DCE and is used to test the DCE functionality. A remote line (analog) loopback occurs at the line port of the remote DCE and is used to test the functionality of the data communications channel. These three loopbacks are initiated in this sequence. The remote DCE is tested by remotely commanding its local loopbacks. Note that LA and LB are direct supersets of the EIA signals LL (Local Loopback) and RL (Remote Loopback).
The local DCE continues to assert CA during all three loopback modes. The remote DCE will deassert CA when remote loopback is in effect. If the remote DCE can detect a local loopback at the local DCE, the remote DCE will deassert its CA; otherwise, the remote DCE will assert its CA when there is a local loopback at the local DCE.
The DCE implements the loopback towards the commanding DTE only. Receive data from the data communications channel is ignored. Send data to the data communications channel is filled with either the commanding DTE's send data stream or with a keep alive data pattern, depending upon the data communications channel's specific requirements.
There is no explicit hardware status signal to indicate that the DCE has entered a loopback mode. The DTE waits for an appropiate amount of time after asserting LA and LB before assuming the loopback to be valid. The appropriate amount of time is application dependent and is not a part of this specification.
The loopback mode applies to both timing and data signals. Thus, on the DTE - DCE link, the same timing signal could traverse the link three times, first as ST, then as TT, and finally as RT.
SG: Signal Ground
Direction: Not Applicable
SG signifies a connection to circuit ground at both ends. SG ensures that the transmit signal levels stay within the common mode input range of the receivers.
SH: Shield
Direction: Not Applicable
The shield encapsulates the cable for EMI purposes, and is not implicitly intended to carry signal return currents. The shield is connected to DTE frame ground directly and may choose one of two options at the DCE frame ground. The first option is to connect the shield to DCE frame ground directly. The second option is to connect the shield to DCE frame ground through a parallel combination of a 470 ohm, +/- 10%, 1/2 watt resistor, 0.1 uF, +/- 10%, 50 volt, monolithic ceramic capacitor, and a 0.01 uF, +/- 10%, 50 volt, monolithic ceramic capacitor. This is shown below:
+-------+ +-------+ | DTE | shield | DCE | | +---------------------- | | | X======== signal path ==========X | | +----------------+----- | | | | C +--||--+ | | | C +--||--+ | | | R +-/\/\-+ | | | | | +-------+ +-------+
The R-C-C network should be located as close to the shield/chassis junction as possible. Because the shield is terminated directly to the DTE and DCE chassis, the shield is not given a pin assignment within the connector. Shield continuity between connecting cables is maintained by the connector housing.
All signals are balanced, differentially driven, and received at standard ECL levels. The ECL negative supply voltage, Vee, may be either -5.2 Vdc +/- 10% or -5.0 Vdc +/- 10% at either end. Rise times and fall times are measured from 20% to 80% threshold levels.
TRANSMITTER: driver type: ECL 10KH with differential outputs (MC10H109, MC10H124 or equivalent) signal levels: minimum typical maximum Voh: -1.02 -0.90 -0.73 Vdc Vol: -1.96 -1.75 -1.59 Vdc Vdiff: 0.59 0.85 1.21 Vdc trise: 0.50 - 2.30 ns tfall: 0.50 - 2.30 ns transmission rate: 52 Mbps maximum signal type: electrically balanced with Non Return to Zero (NRZ) encoding. termination: 330 ohms low inductance resistance from each side to Vee. RECEIVER: receiver type: ECL 10KH differential line receiver (MC10H115, MC10H116, MC10H125, or equivalent) termination: 110 ohms (carbon composition) differential, 5 Kohms common-mode (optional) min. signal level: 150 mvolts peak-to-peak differential max. signal level: 1.0 volt peak-to-peak differential common mode input range: -2.85 volts to -0.8 volts (-0.5 volts max)
Values apply over an ambient temperature range of 0 to 75 degrees Celcius and have been adjusted for the broader Vee range.
In the event that the interface cable is not present, the differential ECL receivers must default to a known state. To guarantee this, it is necessary when using the 10H115 or 10H116 to add a 10 kohm, +/-1%, pull-up resistor to the (-side) of the receiver and a 10 kohm, +/-1%, pull-down resistor to the (+side) of the receiver. This will create a longitudinal termination of 5 kilohms. The default state of all interface signals is deasserted.
It is not necessary to use external resistors when using the 10H125, since it has an internal bias network that will force an output low state when the inputs are left floating.
The interface must not be damaged by an open circuit or short circuit connection on any combination of pins.
Source timing is defined as timing waveforms generated at a transmitter. Destination timing is defined as timing waveforms incident at a receiver. Pulse widths are measured between 50% points of the final pulse amplitude. The leading edge of the timing pulse shall be defined as the boundary between deassertion and assertion. The trailing edge of the timing pulse shall be defined as the boundary between assertion and deassertion. RT, TT, and ST minimum positive source timing pulse width shall be 7.7 ns. This allows a source duty cycle tolerance of +/- 10%. This value is obtained from:
10% = ((9.61 ns - 7.7 ns)/19.23 ns) x 100% where: 19.23 ns = 1 / (52 Mbps) 9.61 ns = 19.23 ns * 1/2 cycle
Data will change to its new state within +/- 3 ns of the leading edge of the source timing pulse.
RT, TT, and ST minimum positive destination timing pulse width shall be 6.7 ns. Data will change to its new state within +/- 5 ns of the leading edge of the destination timing pulse. These numbers allow for transmission distortion elements of 1.0 ns of pulse width distortion and 2.0 ns of clock to data skew. This leaves 1.7 ns for receiver setup time.
The data will be considered valid on the trailing edge. Thus, transmitters clock data out on the leading edge, and receivers clock data in on the trailing edge. This allows an acceptance window for clock-data skew error.
The delay from the ST port to the TT port within the DTE shall be less than 25 ns. The DCE must be able to tolerate a delay of at least 100 ns between its ST port and its TT port. This allows for a 75 ns delay for 15 meters of cable.
RT and ST may be gapped. In the event they become disabled by the DCE, RT disabling must not occur until 23 clock pulses after the last valid data on RD, and ST disabling must not occur until 1 clock pulse after the last valid data on SD. The definition of valid data is application dependent and not a subject of this specification.
CA and TA are asynchronous of each other. Upon assertion of CA, the signals ST, RT, and RD will not be considered valid for at least 40 ns. Upon the assertion of TA, the signals TT and SD will not be considered valid for at least 40 ns. This is intended to allow the receiving end sufficient setup time.
TA should not be deasserted until at least one clock pulse after the last valid data bit on SD has been transmitted. This does not apply to CA since the data is transparent to the DCE.
The cable connecting the DCE and DTE consists of 25 twisted pairs with an overall foil/braid shield. The cable connectors are both male connectors. The DTE and DCE have female receptacles. Dimensions are given in meters (m) and feet (ft).
cable type: multi-conductor cable, consisting of 25 twisted pairs cabled together with an overall double shield and PVC jacket gauge: 28 AWG, 7 strands of 36 AWG, tinned annealed copper, nominal 0.015 in. diameter insulation: polyethylene or polypropylene; 0.24 mm, .0095 in. nominal wall thickness; 0.86 mm +/- 0.025 mm, .034 in. +/- 0.001 in. outside diameter foil shield: 0.051 mm, 0.002 in. nominal aluminum/polyester/ aluminum laminated tape spiral wrapped around the cable core with a 25% minimum overlap braid shield: braided 36 AWG, tinned plated copper in accordance with 80% minimum coverage jacket: 75 degrees C flexible polyvinylchloride jacket wall: 0.51 mm, 0.020 in. minimum thickness dielectic strength: 1000 VAC for 1 minute outside diameter: 10.41 mm +/- 0.18 mm, 0.405 in. +/- 0.015 in. agency complience: CL2, UL Subject 13, NEC 725-51(c) + 53(e) manufacturer p/n: QUINTEC (Madison Cable 4084) ICONTEC RTF-40-25P-2 (Berk-tek, C&M)
maximum length: 15 m 50 ft nominal length: 2 m 6 ft maximum DCR at 20 C: 23 ohms/km 70 ohms/1000ft differential impedance at 50 MHz: nominal: (95% or more pairs) 110 ohms (+/- 11 ohms) maximum: 110 ohms (+/- 15 ohms) signal attenuation at 50 MHz: 0.28 dB/m 0.085 dB/ft mutual capacitance within pair, minimum: 34 pF/m 10.5 pF/ft nominal: (95% or more pairs) 41 pF/m 12.5 pF/ft (+/- 10%) maximum: 48 pF/m 15.0 pF/ft capacitance, pair to shield, maximum: 78 pF/m 24 pF/ft delta: 2.6 pF/m 0.8 pF/ft propagation delay, maximum: (65% of c) 5.18 ns/m 1.58 ns/ft delta: 0.13 ns/m 0.04 ns/ft
plug connector type: 2 row, 50 pin, shielded tab connectors AMP plug part number 749111-4 or equivalent AMP shell part number 749193-2 or equivalent receptacle type: 2 row, 50 pin, receptical header with rails and latch blocks. AMP part number 749075-5, 749903-5 or equivalent
Signal Name Dir. Pin # (+side) Pin # (-side) ----------------------- ---- ------------- ------------- SG - Signal Ground --- 1 26 RT - Receive Timing <-- 2 27 CA - DCE Available <-- 3 28 RD - Receive Data <-- 4 29 - reserved <-- 5 30 ST - Send Timing <-- 6 31 SG - Signal Ground --- 7 32 TA - DTE Available --> 8 33 TT - Terminal Timing --> 9 34 LA - Loopback circuit A --> 10 35 SD - Send Data --> 11 36 LB - Loopback circuit B --> 12 37 SG - Signal Ground --- 13 38 5 ancillary to DCE --> 14 - 18 39 - 43 SG - Signal Ground --- 19 44 5 ancillary from DCE <-- 20 - 24 45 - 49 SG - Signal Ground --- 25 50
Pin pairs 5&30, 14&30 to 18&43, and 20&45 to 24&49 are reserved for future use. To allow future backward compatibility, no signals or receivers of any kind should be connected to these pins.
(Appendices A&B not available)
This appendix calculates the noise immunity of this interface. The normal specified 150 mvolts of noise immunity for 10KH ECL is not applicable here because the differential inputs do not use the internal ECL bias Vbb.
The common mode (NMcm) and differential mode (NMdiff) noise margins for the 10H115 and 10H116 differential line receivers are:
NMcm+ = Vcm_max - Voh_max = -0.50 Vdc - (-0.81 Vdc) = 310 mVdc NMcm- = Vol_min - Vcm_min = -1.95 Vdc - (-2.85 Vdc) = 900 mVdc NMdiff = Vod_min * length * attenuation/length - Vid_min = 10^((20log(.59) - 50(.085))/20) - 150 mv = 361 mv in dB: = 20log(.361) - 20log(.15)
Voltages are at 25 degrees Celcius. Vcm_max was chosen to be 100 mv below the saturation point of Vih = -0.4 volts.
The 10H125 differential receiver has a +5 Vdc supply and can handle a larger positive excursion on its input. The noise margin performance of the 10H125 is:
NMcm+ = Vcm_max - Voh_max = 1.19 Vdc - (-0.81 Vdc)
NMcm- and NMdiff are the same for all parts. To allow the use of all receivers, the worst case common mode noise at the receiver must be limited to 310 mvdc.
Interpret the common mode range, Vcm_max to Vcm_min, as the maximum range of absolute voltages that may be applied to the receiver's input, independent of the applied differential voltage. The signal voltage range, Voh_max to Vol_min, represents the maximum range of absolute voltages that the transmitter will produce. The difference between these two ranges represents the common mode noise margins, NMcm+ and NMcm-, with NMcm+ being the maximum excursion for additive common mode noise, and NMcm- being the maximum excursion for subtractive common mode noise.
With five 50-foot twisted pair grounds, the amount of ground loop current required to use up the common mode noise margin is:
I_ground = NMcm+ / (cable_resistance/5 pairs) = (310 mVdc) / (70 mohms/foot x 50 feet / 10 wires) = 0.9 amps dc
This amount of current should never be present under normal operating conditions.
Common mode noise will have a negligible effect on the differential noise margin, Vdf_app. Rather, Vdf_app would be affected by noise being introduced by one side of the power rails at the transmitter. ECL Vcc has a power supply rejection ratio (PSRR) of 0 dB while ECL Vee has a PSRR on the order of 38 dB. Thus, to minimize differential noise, Vcc is grounded and Vee is connected to a negative power supply.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
11-Dec-2001 |
Initial Release |