Header check sum is XORed with the COSET function (0x55) per CCITT I.361
ATM Layer Counters:
Number of cells received good
Number of cells received and discarded due to bad HEC
Number of cells transmitted good
Number of cells received from cell bus
Number of cells transmitted to cell bus
Diagnostics:
Header of first cell received with invalid egress
translation entries
Number of cells dropped due to invalid egress
translation entries
Loss of Signal (LOS)
Severely Errored Framing (SEF)
Loss of Frame (LOF)
Line Alarm Indication Signal (AIS-L)
STS Path Alarm Indication Signal (AIS-P)
Line Remote Defect Indication (RDI-L)
Loss of Pointer (LOP)
STS Path Remote Defect Indication (RDI-P)
Transmission Convergence Protocol:
Per GR-253-CORE and ANSI T1.105
TC Layer Alarm:
Loss of Cell Delineation ((LCD)
ATM Layer Protocol:
Header check sum is XORed with the COSET function (0x55) per CCITT I.361
ATM Layer Counters:
Number of cells received good
Number of cells received and discarded due to bad HEC
Number of cells transmitted good
Diagnostics:
Number of cells received from Cell Bus
Number of cells transmitted to Cell Bus
Number of unacknowledged cells transmitted to Cell Bus
Header of first cell received with invalid egress translation errors
Number of cells dropped due to invalid ingress translation errors
Number of cells dropped due to invalid etress translation entries.
Derives 8 kHz shelf synchronization clock from a variety of sources:
Internal 8 kHz (±10 ppm)
BNM-155 PLCP
External T1/E1 clock port with a clock rate of
1.544 MHz ±50 ppm (T1) or 2.048 MHz ± 100 bps (E1)
External Clock Interface
DB-15 connector or BNC connector (both are available)
Alarm Interface
CO compatible alarm indicator and controls via DB-15 connector
Indicators
Ten LEDs
· Per Card
Active (Green)
Failed (Red)
Standby (Amber)
· OC-3 Interface
Single multi-hue LED
Active and OK (Green)
Active and Local Alarm (Red)
Active and Remote Alarm (Amber)
· Shelf Voltage
A Voltage OK (Green)
B Voltage OK (Green)
· Alarms
Major (Red)
Minor (Amber)
ACO (Amber)
History (Green)
BNC-3T#
Standby SM requires a special Line Module:
R-DB15-4T1 if active cards use DB15-4T1
R-DB15-4E1 if active cards use DB15-4E1
R-BNC-4E1 if active cards use BNC
R-RJ48-8T1 if active cards use RJ-48-8T1
R-RJ48-8E1 if active cards use RJ-48-8E1
R-SNB-4E1 if active cards use SMB-8E1
Transmitter may be either loop-timed to Receiver or synchronized to shelf (called normal mode)
Input Jitter Tolerance:
Per ATT TR 62411
Output Jitter Generation:
Per ATT TR 62411 using normal mode synchronization
Physical Layer Alarms:
LOS, OOF, AIS, RAI
Number of Frame Relay Ports:
1-Single frame relay stream occupying n consecutive time slots
Frame Relay Interface Rates:
Either 56 Kbps or n*64 Kbps; n as defined above
Frame Relay Interface:
Per ANSI T1.618, 2-octet header
Frame Relay Performance Counters (per Port; n x DS0):
Receive frames discarded due to Aborts
Receive frames discarded due to illegal header (EA bit)(s)
Receive frames discarded due to CRC errors (s)
Receive frames discarded due to alignment errors (s)
Receive frames discarded due to unknown DLCI (s)
Receive frames discarded due to illegal frame length (s)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (s)
Receive bytes (s)
Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (s)
Transmit bytes discarded due to egress Q-depth exceeded (s)
Transmit frames discarded due to egress DE threshold
exceeded Transmit frames (s)
Transmit bytes(s)
Transmit Frames with FECN set (s)
Transmit Frames with BECN set (s)
LMI receive status inquiry request count (s)
LMI transmit status inquiry request count
LMI invalid receive status count (s)
LMI signaling protocol (keep alive time-out count) (s)
LMI sequence number error count (s)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (s)
Transmit bytes during LMI alarm (s)
LMI update status transmit count (in response
to configuration changes)
256 per cardmay be allocated across any of the frame relay interfaces
Counters:
Service Counters:
Number of frames received (s)
Number of bytes received (s)
Number of frames received with DE already set (s)
Number of bytes received with DE already set (s)
Number of frames received with unknown DLCI
Number of frames received but discarded (s)
Number of received bytes discarded (s)
Number of received bytes discarded due to exceeded Q-depth (s)
Number of frames received and discarded due to: intershelf alarm
exceeded DE threshold (s)
exceeded Q depth (s)
Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (s)
Number of bytes transmitted (s)
Number of frames transmitted with DE set (s)
Number of frames discarded due to reassembly errors (s)
Number of frames transmitted during LMI logical port alarm(s)
Number of frames transmitted with FECN set (s)
Number of frames transmitted with BECN set (s)
Number of transmit frames discarded (s)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (s)
egress Q depth exceeded (s)
egress DE threshold exceeded source abort
physical link failure (T1)
ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (s)
Number of OAM FERF cells transmitted (s)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (s)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (s)
Number of OAM FERF cells received (s)
Number of BCM cells received
Number of OAM end-end loopback cells received (s)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (s)
Statistics:
All of the above counters followed by an (s) can be configured as statistics
Diagnostics:
Last unknown LCN received Cells with unknown LCN count
Transmitter may be either loop-timed to Receiver or synchronized to shelf (called normal mode).
Input Jitter Tolerance:
Per G.703.
Output Jitter Generation:
Per G.703.
Physical Layer Alarms:
LOS, OOF, AIS, RAI.
Number of Frame Interfaces:
I to 31 occupying n where 1 < n < 31. Sum of all < 31 for CCS. 1-30 for CAS.
Frame Relay Interface Rates:
Either 56 Kbps or n*64 Kbps; n as defined above.
Frame Relay Interface:
Per ANSI T1.618, 2-octet header.
Frame Relay Performance Counters (per Port; n x DS0):
Receive frames discarded due to Aborts
Receive frames discarded due to illegal header (EA bit)(s)
Receive frames discarded due to CRC errors (s)
Receive frames discarded due to alignment errors (s)
Receive frames discarded due to unknown DLCI (s)
Receive frames discarded due to illegal frame length (s)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (s)
Receive bytes (s)
Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (s)
Transmit bytes discarded due to egress Q-depth exceeded (s)
Transmit frames discarded due to egress DE threshold exceeded Transmit frames (s)
Transmit bytes(s)
Transmit Frames with FECN set (s)
Transmit Frames with BECN set (s)
LMI receive status inquiry request count (s)
LMI transmit status inquiry request count
LMI invalid receive status count (s)
LMI signaling protocol (keep alive time-out count) (s)
LMI sequence number error count (s)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (s)
Transmit bytes during LMI alarm (s)
LMI update status transmit count (in response to configuration changes)
256 per cardmay be allocated across any of the frame relay interfaces
Counters:
Service Counters: Number of frames received (s)
Number of bytes received (s)
Number of frames received with DE already set (s)
Number of bytes received with DE already set (s)
Number of frames received with unknown DLCI
Number of frames received but discarded (s)
Number of received bytes discarded (s)
Number of received bytes discarded due to exceeded Q-Depth (s)
Number of frames received and discarded due to:
intershelf alarm
exceeded DE threshold (s)
exceeded Q depth (s)
Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (s)
Number of bytes transmitted (s)
Number of frames transmitted with DE set (s)
Number of frames discarded due to reassembly errors (s)
Number of frames transmitted during LMI logical port alarm(s)
Number of frames transmitted with FECN set (s)
Number of frames transmitted with BECN set (s)
Number of transmit frames discarded (s)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (s)
egress Q depth exceeded (s)
egress DE threshold exceeded source abort physical link failure (T1)
ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (s)
Number of OAM FERF cells transmitted (s)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (s)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (s)
Number of OAM FERF cells received (s)
Number of BCM cells received
Number of OAM end-end loopback cells received (s)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (s)
Statistics: All of the above counters followed by an (s) can be configured as statistics.
Diagnostics:8Last unknown LCN received
Cells with unknown LCN count
Card General
Indicators:
Per Card: Active (Green), Standby (Yellow), Fail (Red)
Lines (one per): Active & Okay (Green),
Active & Local Alarm (Red),
Active & Remote Alarm (Yellow)
Maintenance/Serviceability Features:
Internal Problem Isolation Loopbacks
Hot-pluggable
Card Size:
FRSM-4E1: 7.25" x 16.25"
LM-DB15-4E1: 7.0" x 4.5"
LM-BNC-4E1: 7.0" x 4.5"
Power:
-48VDC, 30W (4 E1s)
Ingress:
8000 cell buffer shared between virtual channels/paths
Standard Usage Parameter Control (UPC)
Selective Cell Discard
Virtual Circuit Queuing
EFCI setting per VC
Egress:
8000 cell storage capacity shared between four ports
Up to 12 user selectable Egress Queues per port
Selective Cell Discard
EFCI setting per Queue
Transmitter may be either loop-timed to Receiver or synchronized to shelf (called normal mode)
Input Jitter Tolerance:
Per ATT TR 62411
Output Jitter Generation:
Per ATT TR 62411 using normal mode synchronization
Physical Layer Alarms:
LOS, OOF, AIS, RAI
Number of Frame Relay Ports:
1-Single frame relay stream occupying n consecutive time slots
Frame Relay Interface Rates:
Either 56 Kbps or n*64 Kbps; n as defined above
Frame Relay Interface:
Per ANSI T1.618, 2-octet header
Frame Relay Performance Counters (per Port; n x DS0):
Receive frames discarded due to Aborts
Receive frames discarded due to illegal header (EA bit)(s)
Receive frames discarded due to CRC errors (s)
Receive frames discarded due to alignment errors (s)
Receive frames discarded due to unknown DLCI (s)
Receive frames discarded due to illegal frame length (s)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (s)
Receive bytes (s)
Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (s)
Transmit bytes discarded due to egress Q-depth exceeded (s)
Transmit frames discarded due to egress DE threshold
exceeded Transmit frames (s)
Transmit bytes(s)
Transmit Frames with FECN set (s)
Transmit Frames with BECN set (s)
LMI receive status inquiry request count (s)
LMI transmit status inquiry request count
LMI invalid receive status count (s)
LMI signaling protocol (keep alive time-out count) (s)
LMI sequence number error count (s)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (s)
Transmit bytes during LMI alarm (s)
LMI update status transmit count (in response
to configuration changes)
256 per cardmay be allocated across any of the frame relay interfaces
Counters:
Service Counters:
Number of frames received (s)
Number of bytes received (s)
Number of frames received with DE already set (s)
Number of bytes received with DE already set (s)
Number of frames received with unknown DLCI
Number of frames received but discarded (s)
Number of received bytes discarded (s)
Number of received bytes discarded due to exceeded Q-depth (s)
Number of frames received and discarded due to: intershelf alarm
exceeded DE threshold (s)
exceeded Q depth (s)
Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (s)
Number of bytes transmitted (s)
Number of frames transmitted with DE set (s)
Number of frames discarded due to reassembly errors (s)
Number of frames transmitted during LMI logical port alarm(s)
Number of frames transmitted with FECN set (s)
Number of frames transmitted with BECN set (s)
Number of transmit frames discarded (s)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (s)
egress Q depth exceeded (s)
egress DE threshold exceeded source abort
physical link failure (T1)
ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (s)
Number of OAM FERF cells transmitted (s)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (s)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (s)
Number of OAM FERF cells received (s)
Number of BCM cells received
Number of OAM end-end loopback cells received (s)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (s)
Statistics:
All of the above counters followed by an (s) can be configured as statistics
Diagnostics:
Last unknown LCN received Cells with unknown LCN count
RJ-48 when used with LM-RJ-48-8E1 line module.
SMB when used with LM-SMB-8E1 line module
Line Rate:
2.048 Mbps ± 100 bps
Synchronization:
Transmitter may be either loop-timed to Receiver or synchronized to shelf (called normal mode)
Input Jitter Tolerance:
Per G.703
Output Jitter Generation:
Per G.703
Physical Layer Alarms:
LOS, OOF, AIS, RAI
Number of Frame Interfaces:
I to 31 occupying n where 1 < n < 31. Sum of all < 31 for CCS 1-30 for CAS
Frame Relay Interface Rates:
Either 56 Kbps or n*64 Kbps; n as defined above
Frame Relay Interface:
Per ANSI T1.618, 2-octet header
Frame Relay Performance Counters (per Port; n x DS0):
Receive frames discarded due to Aborts
Receive frames discarded due to illegal header (EA bit)(s)
Receive frames discarded due to CRC errors (s)
Receive frames discarded due to alignment errors (s)
Receive frames discarded due to unknown DLCI (s)
Receive frames discarded due to illegal frame length (s)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (s)
Receive bytes (s)
Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (s)
Transmit bytes discarded due to egress Q-depth exceeded (s)
Transmit frames discarded due to egress DE threshold exceeded Transmit frames (s)
Transmit bytes(s)
Transmit Frames with FECN set (s)
Transmit Frames with BECN set (s)
LMI receive status inquiry request count (s)
LMI transmit status inquiry request count
LMI invalid receive status count (s)
LMI signaling protocol (keep alive time-out count) (s)
LMI sequence number error count (s)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (s)
Transmit bytes during LMI alarm (s)
LMI update status transmit count (in response to configuration changes)
256 per cardmay be allocated across any of the frame relay interfaces
Counters:
Service Counters: Number of frames received (s)
Number of bytes received (s)
Number of frames received with DE already set (s)
Number of bytes received with DE already set (s)
Number of frames received with unknown DLCI
Number of frames received but discarded (s)
Number of received bytes discarded (s)
Number of received bytes discarded due to exceeded Q-Depth (s)
Number of frames received and discarded due to:
intershelf alarm
exceeded DE threshold (s)
exceeded Q depth (s)
Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (s)
Number of bytes transmitted (s)
Number of frames transmitted with DE set (s)
Number of frames discarded due to reassembly errors (s)
Number of frames transmitted during LMI logical port alarm(s)
Number of frames transmitted with FECN set (s)
Number of frames transmitted with BECN set (s)
Number of transmit frames discarded (s)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (s)
egress Q depth exceeded (s)
egress DE threshold exceeded source abort physical link failure (T1)
ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (s)
Number of OAM FERF cells transmitted (s)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (s)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (s)
Number of OAM FERF cells received (s)
Number of BCM cells received
Number of OAM end-end loopback cells received (s)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (s)
Statistics: All of the above counters followed by an (s) can be configured as statistics.
Diagnostics: 8Last unknown LCN received
Cells with unknown LCN count
Card General
Indicators:
Per Card: Active (Green), Standby (Yellow), Fail (Red)
Lines (one per):Active & Okay (Green)
Active & Local Alarm (Red),
Active & Remote Alarm (Yellow)
Maintenance/Serviceability Features:
Internal Problem Isolation Loopbacks
Hot-pluggable
Card Size:
FRSM-8E1: 7.25" x 16.25"
RJ48-8E1: 7.0" x 4.5"
SMB-8E1: 7.0" x 4.5"
Power:
-48V DC, 30W (8 E1s)
Ingress:
8000 cell buffer shared between virtual channels/paths
Standard Usage Parameter Control (UPC)
Selective Cell Discard
Virtual Circuit Queuing
EFCI setting per VC
Egress:
8000 cell storage capacity shared between four ports
Up to 12 user selectable Egress Queues per port
Selective Cell Discard
EFCI setting per Queue
Number of cells received from the interface.
Number of cells received with unknown VPI/VCI.
Last known VPI/VCI received from the port.
Number of cells discarded due to error in Cell Header.
Number of cells received with non zero GRC field.
Number of cells transmitted to the interface.
Number of cells transmitted for which EFCI was set.
Number of egress cells discarded due to service interface physical alarm.
Endpoint (channel):
Ingress:
Number of cells received from port.
Number of cells received from the port with CLP = 1.
Number of cells received from the port with EFCI = 1.
No, of cells from the port discarded due to queue exceeded QDepth.
Number of cells (with CLP) set) discarded due to queue exceeded CLP threshold.
Number of cells from the port for which CLP was set due to UPC violations.
ATMizer channel counters:
Ingress:
Number of cells transmitted to CellBus.
Number of cells to cell bus for which EFCI was set.
Number of cells to cell bus discarded due to shelf alarm.
Egress:
Number of cells received from the CellBus.
Number of cells discarded due to queue exceeded QDepth
(per Egress Q).
Number of cells discarded due to queue exceeded CLP threshold (per Egress Q).
Number of cells received with CLP = 1.
Other Counters:
.
Ingress:
Number of OAM cells discarded.
Number of AIS cells received from the port.
Number of RDI (FERF) cells received from the port.
Number SegmentLpBk cells received from the port.
Number of SegmentLpBk cells transmitted to CellBus.
Egress:
Number of OAM cells discarded.
Number of AIS cells transmitted to the port.
Number of SegmentLpBk cells transmitted to the port.
Number of SegmentLpBk cells received from the port.
One per line: Active & OK (green)
Active and Local Alarm (red)
Active and Remote Alarm (yellow)
Maintenance/Servicability:
Facility loopback via Loop up/down per ANSI T1.408 &
ATT TR 62411 (T1), CCITT G.7xx (E1)
Facility Loopback via Management Console
Internal Problem Isolation Loopbacks
Hot pluggable
Card Size:
7.25" x 15"
Power:
-48VDC, 30 W
Safety:
EN 60950 2nd edition (including EN 41003) UL 1950
2nd edition
Number of lost SAR-PDUs
Number of buffer overflow events
Number of buffer underflow events
Number of SAR-PDU's with header error
Number of SAR-PDU's received out of sequence
Number of cells played out to T1/E1 port
Number of cell generated from T1/E1 port
Number of bytes discarded due to shelf alarm,from port
Number of all 1's cells inserted during buffer underflow
Number of bytes discarded due to egress overflow
DS3/E3 physical layer line alarm indication and insertion
DS3/E3 SUNI-PDh number of cells:Tx and Rx
PLL clock recovery status
AIM Group:
Number of cells received from AIM interface
Number of cell discarded due to error in Cell Header
Number of cells from AIM interface discarded due to Queue Full on both Ingress and Egress directions
Number of ACP cells received
Number of ACP cells received with errors
Number of LCP cells received
Number of LCP cells received with errors
Number of cells served from Egress queue to AIM interface
Number of cell transmitted by trunk interface, two types: Date and Filler + Data
Number of times a link went off the IMAIM group
ATMizer (Cellbus) counters:
Ingress:
Numberof cells transmitted
Number of cells discarded due to shelf alarm
Egress:
Number of cells received
Numberof cells discarded due to queue depth exceeded QDepth