Catalyst 1200 Installation and Configuration Guide
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Product Overview
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Table of ContentsProduct OverviewSummary of Features
Front Panel Rear Panel A/B Port Card Slot
Technical SpecificationsPower Receptacle Optical Bypass Switch Receptacle and LED Admin. Port Ethernet Ports SUM Port CDDI-FDDI Translator Product OverviewThe Catalyst 1200 series switch is an Ethernet-to-Ethernet and Ethernet-to-CDDI/FDDI switch that provides high-speed transparent bridging between Ethernets and high-speed translational bridging between Ethernet and Copper Distributed Data Interface (CDDI) or Fiber Distributed Data Interface (FDDI). The Catalyst 1200 series switch includes four models: WS-C1201, WS-C1202, WS-C1211, and WS-C1212. Using content-addressable memory (CAM) technology, models WS-C1201 and WS-C1211 can learn up to 1,024 Ethernet addresses, and models WS-C1202 and WS-C1212 can learn up to 4,096 Ethernet addresses. The switch has eight 10-Mbps Ethernet ports and two 100-Mbps CDDI or FDDI ports that comply fully with the FDDI and American National Standards Institute (ANSI) draft specifications for CDDI multilevel transmission (MLT-3) A and B ports. The eight 802.3 Ethernet ports are 10BaseT (T for twisted pair) on the WS-C1201 model or 10BaseF (F for fiber) on the WS-C1211 model. The switch can sit on a desktop, mount on a wall, or mount in an Electronic Industries Association (EIA)-compliant 19-inch open or closed rack. Note Throughout this document, the Catalyst 1200 series switch is referred to as Catalyst Switch or the switch. Summary of FeaturesFollowing are the features of the Catalyst 1200 series switch:
Note Prior to the acceptance of the EIA/TIA standard by the ANSI committee, it was referred to as the RS-232 recommended standard.
The Catalyst 1200 series switch complies fully with FDDI Station Management (SMT) Specification Revision 7.3. A network administrator can monitor and control the switch from anywhere on the network using any SNMP management station. Note Throughout this publication, CDDI refers specifically to the CDDI/MLT-3 standard. Front PanelThe front panel of the switch has LED indicators for switch, ring, and port status as shown in Figure 1-1 and Figure 1-2. Figure 1-1: Catalyst Series Switch--Front-Panel View (Plastic Panel Removed) ![]() Figure 1-2: Catalyst Series Switch--Front-Panel View (Plastic Panel Installed) ![]() Note The Catalyst 1200 series switch is shipped with the plastic front and side panels removed. Instructions for installing the front and side panels are included in the section "Wall-Mounting" in the chapter "Hardware Installation." The side panels are required for wall-mounting. LEDsTable 1-1 lists the descriptions of the front-panel LEDs, which are shown in Figure 1-3 and Figure 1-4. Use the LED descriptions in Table 1-1 to verify proper operation and for troubleshooting. Figure 1-3: LED Indicators--Partial Front-Panel View (Plastic Panel Removed) ![]() Figure 1-4: LED Indicators--Partial Front-Panel View (Plastic Panel Installed) ![]() Table 1-1: Front-Panel LED Descriptions
Reset SwitchAccess to the reset switch, which is located behind the front panel, is through a small hole approximately one and a half inches to the right of the front-panel LEDs. (See Figure 1-5 or Figure 1-6.) Figure 1-5: Reset Switch--Partial Front-Panel View (Plastic Panel Removed) ![]() Figure 1-6: Reset Switch--Partial Front-Panel View (Plastic Panel Installed) ![]() Note To reset the switch, use a thin tool (such as a small screwdriver) to press and release the button. Rear PanelThe rear panel of the switch has an AC power receptacle, an optical bypass switch receptacle and LED, an EIA-TIA-232 admin. port, a card slot for an optional CDDI or FDDI A/B port card, eight Ethernet 10BaseT (WS-C1201) or 10BaseF (WS-C1211) ports, and the SUM interface port (and LEDs). (See Figure 1-7.) Figure 1-7: Catalyst Series Workgroup Switch--Two Rear-Panel Views ![]() The chassis has no power ON/OFF switch. Power is applied when the power cable is connected between the switch and the AC source. A/B Port Card SlotThe A/B card slot supports the following configuration: single-MAC DAS with dual homing configuration for FDDI (can also be used as an SAS). The A/B card slot also accepts CDDI/MLT-3 port cards. See Figure 1-8 for unshielded twisted-pair (UTP) and shielded twisted-pair (STP) connections. Following are the three models of A/B port cards available:
Figure 1-8: CDDI and FDDI A/B Port Cards ![]() The A/B port cards allow the switch to connect to a dual ring as a peer connection or to the master (M) port of another concentrator (cascaded tree configuration). To add an A and B port to the switch, insert an optional A/B port card. For A/B port card installation, see the chapter "Hardware Installation." Power ReceptacleThe power receptacle uses the AC power cord supplied with the switch. The power supply automatically accepts either 110 volts alternating current (VAC) or 230 VAC. To apply power, attach the power cord. To disconnect power, remove the power cord. There is no On/Off switch. Optical Bypass Switch Receptacle and LEDThe 6-pin mini-Deutsche Industrie Norm (DIN) connector is used to connect an external optical bypass switch to the switch. When idle, the optical bypass switch removes the nonfunctional dual attachment switch from the ring. An activated bypass switch inserts the Catalyst Switch into the ring. Use an optical bypass switch only with the A/B port card option. If you install or remove an optical bypass switch, you must reset the Catalyst Switch. The bypass LED is on when the bypass switch is connected. Admin. PortThe admin. port is the console terminal connection to the switch. To use the admin. port, connect an EIA/TIA-232 terminal (configured for 9,600 baud, no parity, eight data bits, and one stop bit), modem, or network management workstation. The admin. port enables you to perform the following functions:
Ethernet PortsPorts 3 through 10 are IEEE 802.3 Ethernet 10BaseT (for the WS-C1201) or IEEE 802.3 Ethernet 10BaseF (for the WS-C1211). The 10BaseT ports use straight-through, RJ-45, modular UTP cables for connection to end systems, and cross-connect, RJ-45, modular cables for connection to other switches and concentrators. The 10BaseF ports use ST-type connections and multimode optical-fiber cable. SUM PortThe stackable unified management (SUM) port is an out-of-band Ethernet 10BaseT port using a female RJ-45 UTP connection. The SUM port uses an RJ-45, modular, cross-connect cable when connecting to end systems; and straight-through cable when connecting to hubs. You can connect the SUM port to an Ethernet 10BaseT hub for Telnet, File Transfer Protocol (FTP), and SNMP management connection to the switch. For LED locations, refer to Figure 1-9. Table 1-2 lists the functions of the four SUM port LEDs. Note The Catalyst Switch cannot bridge or route packets from a port to the console terminal connected through the SUM port. Figure 1-9: SUM Port LEDs--Partial Rear-Panel View ![]() Table 1-2: SUM Port LED Descriptions CDDI-FDDI TranslatorThe optional CDDI-FDDI translator (model number WS-C703) provides a connection between CDDI and FDDI interfaces. The CDDI-FDDI translator includes an AC power adapter. The translator accepts an FDDI media interface connector (MIC) on one end and a CDDI (RJ-45) connection on the other end. Figure 1-10 shows two views of the translator. Figure 1-10: CDDI-FDDI Translator--Two Views ![]() One side of the translator has three status LEDs: FDDI signal detect (FSD), power (PWR), and CDDI signal detect (CSD). The other side of the translator has the power connector. Technical SpecificationsTable 1-3 lists the specifications for the switch. Table 1-3: Technical Specifications
1 EMI = electromagnetic interference. 2 NMP = network management processor. 3 DRAM = dynamic random-access memory. 4 NVRAM = nonvolatile random-access memory. 5 UTP = unshielded twisted-pair. 6 STP = shielded twisted-pair. 7 dBm = decibels per milliwatt. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|