Cisco ONS 15400 Series

Cisco Field Notice: FN - 62586 - 15454-SA-HD and 15454-SA-HD-DDR Shelf Assemblies Have Incorrect Power Filter Capacitor


Revised August 10th, 2009
January 31st, 2007


NOTICE:

THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.

Products Affected

Products Affected Top Assembly Printed Circuit Assembly
Part # Rev. Part # Rev.
15454-SA-HDBNC
800-27446-02 800-27446-03
all
73-10241-05 73-10241-05  
all
15454-SA-HDBNC= 
800-27446-02 800-27446-03 
all
73-10241-05 73-10241-05
all
15454-SA-HD
800-23890-02 800-23890-03 800-23890-04 
all
73-10241-05 73-10241-05 73-10241-05
all
15454-SA-HD-DDR 
800-25931-02 800-25931-03 800-25931-04
all
73-10241-04 73-10241-05 73-10241-05
all
15454-SA-HD-DDR=
800-25931-02 800-25931-03 800-25931-04 
all
73-10241-04 73-10241-05 73-10241-05
all
15454-SA-HD=
800-23890-02 800-23890-03 800-23890-04
all
73-10241-05 73-10241-05 73-10241-05
all

 

Problem Description

Note: Cisco has scheduled ending the Umpire replacement program for this Field Notice on 11/1/2009.

An incorrect capacitor has been installed on some power filter assemblies in 15454 shelves that were manufactured and shipped between December 2005 and July 2006.
These power filter assemblies are used in the 800-xxxxx-03 and -04 shelves only.
Approximately 40% of the shelves shipped may have incorrect capacitors.

Background

The purpose of the filter assembly was to meet Telcordia (GR-1089) EMI requirements. The Telcordia specifications were later changed in 2006, making the capacitor unnecessary.
The capacitors were removed from the design for (15454-SA-HDBNC 800-27446-04 and higher), (15454-SA-HD 800-23890-05 and higher), (15454-SA-HD-DDR 800-25931-05 and higher) version shelves which started shipping in October 2006, so the currently shipping shelves are not at risk.
A small number of shelves with incorrect capacitors can experience a capacitor failure during the normal life of the shelf.

Customers with version as stated in the Products Affected section of this field notice can contact Cisco for a replacement.

As an alternative to complete shelf replacement, Cisco developed an in-service inspection program to aid in identifying incorrectly built power filter assemblies. Version -03 and -04 shelves may be inspected in the field to determine whether an incorrect capacitor is installed. The inspection is not traffic impacting, but it is strongly recommended that it be conducted during a maintenance window. After shelves in the field are inspected, they are labeled by the inspectors with a sticker, if the capacitor is correct.

Note: As the inspection process is manual and relies on a subjective color assessment to determine capacitor type, it is subject to error. Since the initial offering of the inspection program, there have been a small number of known manual inspection escapes, where incorrectly built power filter assemblies were misidentified as correctly built power filter assemblies, and subsequently failed. Analysis is underway on these errors to see if any further corrective action may be warranted. Given the possibility of escapes in the inspection process, Cisco extends the offer to replacement of any shelf covered by the inspection process at the customer's request.

Customers who wish to schedule an inspection may contact Cisco as instructed below.

Problem Symptoms

If an incorrect capacitor is installed in the power filter assembly, and it has sustained a mechanical stress crack, it can cause arcing, smoke and a traffic outage.
There is no safety issue associated with the failure, although traffic on the system will be impacted.

Workaround/Solution

Shelves with incorrect capacitors may be returned for replacement.

If an inspected shelf is determined to have an incorrect capacitor, it may be returned for replacement.

Shelves returned for removal of the capacitors are re-identified with the latest version.

For 15454-SA-HDBNC ( 800-27446-04, 800-27446-05, etc.).
For 15454-SA-HD ( 800-23890-05, 800-23890-06, etc.).
For 15454-SA-HD-DDR ( 800-25931-05, 800-25931-06, etc.).

There is no cost or charge associated to the replacement.

How To Identify Hardware Levels

Serial numbers do not change when a board is reworked to the latest revision of 800 numbers.

In order to determine the Part Number, Hardware Revision and Serial Number of your 15454-SA-HD, or 15454-SA-HD-DDR, or 15454-SA-HDBNC=:

Open Cisco Transport Controller.
From the Shelf View, select Inventory
From the Inventory tab, locate the 15454-SA-HD, 15454-SA-HD-DDR, or 15454-SA-HDBNC shelf and compare the information from the Inventory tab against the Products Affected section above.

If you use TL1 commands.
1. >ACT-USER::
2. >RTRV-INV::ALL
3. >CANC-USER::
Compare the information from the TL1 inventory command against the products Affected section above.

Any customers that have a custom BIC on the back of the shelf/chassis, must remove the BIC before shipping back to Cisco, and save it for the replacement shelf

Upgrade Program

15454-SA-HD, 15454-SA-HD-DDR
If you want to check status on a previously booked upgrade, please refer to the Status Tool (Please note: you must have a sales order number in addition to a CCO User ID and Password to access this site):http://tools.cisco.com/qtc/status/tool/action/LoadOrderQueryScreen

For questions about an upgrade order already submitted, please send an email with your order number in the subject line to:upgrades-support@cisco.com
You will receive a response within 24 hours Monday-Friday not including US Holidays.


Note: Fields marked with an asterisk (*) are required fields.

Requestor Information
*Name
*E-mail Address
TAC SR Number
Customer Shipping Information
*Company
*Address
Address_line2
*City
*State/Province
*ZIP/Postal Code
Country
Product
Product *Quantity *Serial# 2
15454-SA-HD
15454-SA-HD-DDR
Customer Contact Information
*First Name
*Last Name
*Phone 1 Ext.
Fax 1 Ext.
*E-Mail
Please use the following format: user@domain.com
*Upgrade Order Reference Number
Please provide a number that you can use when inquiring about order status
Notes
1 For phone and fax, include 011 and the country code outside North America.

2 When entering more than one serial number in the serial number text entry field, be sure to type a comma between each serial number to separate them.

3 For customers in Japan only *** please enter the building and the floor in the address field. Also, enter the contact person's name, the telephone number and the e-mail address in the appropriate fields..

Revision History

Revision Date Comment
1.6 10-AUG-2009 Updated Workaround/Solution and How to Identify HW levels sections.
1.5 29-MAY-2009 Updated products affected information; updated background section; updated workaround section.
1.4 21-JAN-2009 Added information about Umpire replacement program retirement in November 2009.
1.3 19-JUN-2007 Updated Background section with additional note regarding inspection process
1.2 01-MAR-2007 Corrected Upgrade form.
1.1 05-FEB-2007 Update umpire to remove one PID
1.0 31-JAN-2007 Initial Public Release

For More Information