The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
The Cisco® portfolio of industrial DIN-rail power supplies offers a wide range of options to power your industrial Ethernet switches, industrial routers, and industrial computing products.
The Cisco industrial DIN-rail power supplies offer a variety of rugged, reliable, and compact AC and DC power supply options to power Cisco’s industrial Ethernet switches, industrial routers (including industrial gateways), and industrial computing products. Some key features include:
● Power supply options from 50W to 480W
● Operating temperatures ranging between -40°C and +85°C
● DIN-rail mountable options
● Enablement of high capacity Power over Ethernet (PoE)
● Conformal coating options
Table 1 shows a list of all DIN-rail power supplies.
Table 1. DIN-rail power supplies part numbers and descriptions
Part number |
Product image |
Product description |
PoE / PoE+ support |
PWR-IE50W-AC-L= |
50W AC to DC power supply |
No |
|
PWR-IE50W-AC= |
50W AC to DC or High DC to DC power supply |
No |
|
PWR-IE50W-AC-IEC= |
50W AC to DC power supply with IEC connector (IEC 60320 C14) |
No |
|
PWR-IE65W-PC-AC= |
65W AC to DC or High DC to DC power supply |
Yes |
|
PWR-IE65W-PC-DC= |
65W Low DC to DC power supply |
Yes |
|
PWR-IE170W-PC-AC= |
170W AC to DC or High DC to DC power supply |
Yes |
|
PWR-IE170W-PC-DC= |
170W Low DC to DC power supply |
Yes |
|
PWR-IE240W-PCAC-L= |
240W AC to DC power supply |
Yes |
|
PWR-IE480W-PCAC-L = |
480W AC to DC power supply |
Yes |
Note: PWR-IE240-PCAC-L= and PWR-IE48W-PCAC-L= are conformal-coated PSUs.
Table 2 lists the input specification for Cisco industrial power supplies. Table 3 lists the output specifications.
Product ID |
Rated nominal input operating range |
Supported input voltage operating range |
Typical efficiency |
Inrush current at 25C ambient |
Remarks |
PWR-IE50W-AC-L= |
AC 100-240V/1.2A, 50-60Hz |
AC 90-264V |
88% |
< 35A @ 115VAC and 70A @ 230VAC |
Not approved for hazardous location installations |
PWR-IE50W-AC= |
AC 100-240V/1.25A, 50-60Hz or DC 125-250V/1.25A |
AC 90-264V or DC 106-300V |
80% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations |
PWR-IE50W-AC-IEC= |
AC 100-240V/1.25A, 50-60Hz |
AC 90-264V |
80% |
< 35A @ 115VAC and 70A @ 230VAC |
Not approved for hazardous location installations |
PWR-IE65W-PC-AC= |
AC 100-240V/1.4A, 50-60Hz or DC 125-250V/1.0A |
AC 90-264V or DC 106-300V |
85% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations CSA certified |
PWR-IE65W-PC-DC= |
DC 24-48VDC/4.5A |
DC 18-60V |
92% |
4A@24VDC |
Approved for Class 1, Div 2/Zone 2 installations |
PWR-IE170W-PC-AC= |
AC 100-240V/2.3A, 50-60Hz or DC 125-250V/2.1A |
AC 90-264V or DC 106-300V |
88% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations CSA certified |
PWR-IE170W-PC-DC= |
DC 12-54V/23A |
DC 10.8-60V |
88% |
17.3A @ 12VDC |
Approved for Class 1, Div 2/Zone 2 installations |
PWR-IE240W-PCAC-L= |
AC 100-240V/3.5A, 50-60Hz |
AC 90-264V |
91% |
< 35A @ 115VAC and 230VAC |
Not approved for hazardous location installations |
PWR-IE480W-PCAC-L= |
AC 100-240V/6A, 50-60Hz |
AC 90-264V |
92% |
< 35A @ 115VAC and 230VAC |
Not approved for hazardous location installations |
Table 3 lists the output specifications for Cisco industrial power supplies.
Table 3. Output specifications
Product ID |
Nominal output voltage / adjustment range |
Max output power |
Holdup time at 100% load |
Protections |
PWR-IE50W-AC-L= |
24VDC / 24-28VDC, 2.1A |
50W |
20ms |
Over voltage protection Over current protection Over temperature protection Short circuit protection |
PWR-IE50W-AC= |
24VDC, 2.1A |
50W |
20ms |
|
PWR-IE50W-AC-IEC= |
24VDC, 2.1A |
50W |
20ms |
|
PWR-IE65W-PC-AC= |
54VDC, 1.2A |
65W |
10ms |
|
PWR-IE65W-PC-DC= |
54VDC, 1.2A |
65W |
|
|
PWR-IE170W-PC-AC= |
54VDC, 3.2A |
170W |
20ms |
|
PWR-IE170W-PC-DC= |
54VDC, 3.2A |
170W |
9ms (@10.8VDC) to 25.9ms (@ 60VDC) |
|
PWR-IE240W-PCAC-L= |
54VDC / 48-56VDC, 4.5A |
240W |
20ms |
|
PWR-IE480W-PCAC-L= |
54VDC / 48-56VDC, 8.9A |
480W |
20ms |
Table 4 lists the environmental specifications for Cisco industrial power supplies.
Table 4. Environmental specifications
Product ID |
IP rating |
Operating temperature |
Storage temperature |
Power derating |
Operating humidity |
PWR-IE50W-AC-L= |
IP20 |
-20°C to +70°C |
-40°C to +85°C |
> 55°C de-rate power by 3.33%/°C < -10°C de-rate power by 2%/°C |
5 to 95% RH (non-condensing) |
PWR-IE50W-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE50W-AC-IEC= |
IP20 |
-20°C to +70°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE65W-PC-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE65W-PC-DC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE170W-PC-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE170W-PC-DC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE240W-PCAC-L= |
IP20 |
-40°C to +80°C |
-40°C to +85°C |
Vertical mounting: > 50°C de-rate power by 2.5%/°C Horizontal mounting: > 40°C de-rate power by 2.5%/°C |
5 to 95% RH (non-condensing) |
PWR-IE480W-PCAC-L= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
Vertical mounting: > 50°C de-rate power by 2.5%/°C > 70°C de-rate power by 5%/°C |
5 to 95% RH (non-condensing) |
Table 5 lists the Safety standards/EMC for Cisco industrial power supplies.
Table 5. Safety standards / EMC
Product ID |
Electric safety |
EMC/ Industry standards |
PWR-IE50W-AC-L= |
CE (EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC) UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 CB scheme to IEC 60950-1, LPS NEC Class 2 |
EN 61000-3-2 Class A, EN 61000-3-3 EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61204-3, EN 55035 (EN 61000-4-2,3,4,5,6,8,11 ) CISPR 32, EN 55032, CISPR 11, EN 55011, FCC 47 CFR part 15B |
PWR-IE50W-AC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN61131-2: 2007 EN62368-1: 2014 + A11: 2017 IEC60950-1: 2005+A1: 2009+A2: 2013 IEC62368-1: 2014 EN 60079-0:2012 + A11:2013, EN 60079-15:2010 CE |
EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11 IEC61000-4-11, IEC61000-4-12, IEC61000-4-16 CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B |
PWR-IE50W-AC-IEC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN62368-1: 2014 + A11: 2017 CE |
EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11 IEC61000-4-11, IEC61000-4-12, IEC61000-4-16 CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B |
PWR-IE65W-PC-AC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN61131-2: 2007 EN62368-1: 2014 + A11: 2017 IEC60950-1: 2005+A1: 2009+A2: 2013 IEC62368-1: 2014 UL 508 Class 1, Div 2/ Zone 2 Hazardous location CE UL60950-1 and CSA60950-1 certified |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12, EN61131-2: 2007 CISPR 32, EN 55032, CISPR35, EN55035 FCC47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
PWR-IE65W-PC-DC= |
EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 508 Class 1, Div2/ Zone 2 Hazardous Location CCC CE |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
PWR-IE170W-PC-AC= |
IEC60950-1: 2005+A1: 2009+A2: 2013 EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, KCC mark, BSMI mark, CCC, CB Scheme, Class 1, Div2/ Zone 2 Hazardous Location CE UL60950-1and CSA60950-1 certified |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12 CISPR 32, EN 55032, CISPR35, EN55035 47 CFR FCC part 15B EN61131-2: 2007 IEC 61850-3, IEEE 1613 |
PWR-IE170W-PC-DC= |
EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 508 Class 1, Div 2/Zone 2 Hazardous location CE |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
PWR-IE240W-PCAC-L= |
SIQ Bauart to EN 60950-1 UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) |
EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12) CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR Part15B |
PWR-IE480W-PCAC-L= |
SIQ Bauart to EN 60950-1 UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) |
EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12) CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR Part 15B |
Table 6 lists the Mechanical and Reliability data for Cisco industrial power supplies.
Table 6. Mechanical and Reliability data
Product ID |
Dimensions (W x H x D) |
Unit weight |
MTBF (Telcordia SR-332) |
PWR-IE50W-AC-L= |
30 mm x 75 mm x 89.5 mm 1.18 in x 2.95 in x 3.52 in |
0.39 lb (0.18 kg) |
2,255,613 hours |
PWR-IE50W-AC= |
51 mm x 118 mm x 148 mm 2 in x 4.64 in x 5.82 in |
1.41 lb (0.64 kg) |
1,662,359 hours |
PWR-IE50W-AC-IEC= |
51 mm x 118 mm x 148 mm 2 in x 4.64 in x 5.82 in |
1.43 lb (0.65 kg) |
1,662,359 hours |
PWR-IE65W-PC-AC= |
66 mm x 148 mm x 118 mm 2.5 in x 5.82 in x 4.64 in |
2.64 lb (1.2 kg) |
2,488,401 hours |
PWR-IE65W-PC-DC= |
66 mm x 150 mm x 117 mm 2.59 in x 5.90 in x 4.60 in |
2.60 lb (1.18 kg) |
4,802,673 hours |
PWR-IE170W-PC-AC= |
96 mm x 150 mm x 146 mm 3.77 in x 5.90 in x 5.74 in |
3.88 lb (1.76 kg) |
2,384,975 hours |
PWR-IE170W-PC-DC= |
114 mm x 150 mm x 146 mm 4.48 in x 5.90 in x 5.74 in |
3.68 lb (1.67 kg) |
2,164,641 hours |
PWR-IE240W-PCAC-L= |
85 mm x 121 mm x 124.1 mm 3.34 in x 4.76 in x 4.88 in |
2.11 lb (0.96 kg) |
1,579,900 hours |
PWR-IE480W-PCAC-L= |
144 mm x 121 mm x 118.6 mm 5.66 in x 4.76 in x 4.66 in |
3.02 lb (1.37 kg) |
1,058,750 hours |
Table 7 provides ordering information for Cisco industrial power supplies.
Part # |
Product description |
PWR-IE50W-AC-L= |
50W AC to DC power supply |
PWR-IE50W-AC= |
50W AC to DC power supply |
PWR-IE50W-AC-IEC= |
50W AC to DC power supply with IEC connector (IEC 60320 C14) |
PWR-IE65W-PC-AC= |
65W AC to DC power supply |
PWR-IE65W-PC-DC= |
65W DC to DC power supply |
PWR-IE170W-PC-AC= |
170W AC to DC power supply |
PWR-IE170W-PC-DC= |
170W DC to DC power supply |
PWR-IE240W-PCAC-L= |
240W AC to DC power supply |
PWR-IE480W-PCAC-L= |
480W AC to DC power supply |
Cisco offers a five-year limited warranty on all industrial Ethernet power supplies. Warranty information is available at https://www.cisco-servicefinder.com/warrantyfinder.aspx.
Cisco environmental sustainability
Information about Cisco’s environmental sustainability policies and initiatives for our products, solutions, operations, and extended operations or supply chain is provided in the “Environment Sustainability” section of Cisco’s Corporate Social Responsibility (CSR) Report.
Reference links to information about key environmental sustainability topics (mentioned in the “Environment Sustainability” section of the CSR Report) are provided in the following table:
Sustainability topic |
Reference |
Information on product material content laws and regulations |
|
Information on electronic waste laws and regulations, including products, batteries, and packaging |
Reference links to product-specific environmental sustainability information that is mentioned in relevant sections of this data sheet are provided in the following table:
Sustainability Topic |
Reference |
Power |
|
Power specifications and consumption |
Table 1. DIN-rail power supplies part numbers and descriptions |
Environmental Characteristics |
|
Operating temperature, industry standards, EMC emissions |
|
Material |
|
Unit Weight |
Table 4. Environmental Specifications - Mechanical / Reliability data |
Cisco makes the packaging data available for informational purposes only. It may not reflect the most current legal developments, and Cisco does not represent, warrant, or guarantee that it is complete, accurate, or up to date. This information is subject to change without notice.
Flexible payment solutions to help you achieve your objectives
Cisco Capital makes it easier to get the right technology to achieve your objectives, enable business transformation and help you stay competitive. We can help you reduce the total cost of ownership, conserve capital, and accelerate growth. In more than 100 countries, our flexible payment solutions can help you acquire hardware, software, services and complementary third-party equipment in easy, predictable payments. Learn more.
New or Revised Topic |
Described In |
Date |
Removed IP67 power supplies from this datasheet as they are not “DIN Rail” mountable |
Entire Datasheet |
December, 2019 |
Updated Images and certifications |
Entire Datasheet |
December, 2023 |