When attempting to monitor a Windows event on another Windows server, the event trigger does not register.
Tidal Enterprise Orchestrator (TEO) 2.1 or later
Windows Trigger
Refer to Cisco Technical Tips Conventions for more information on document conventions.
The Windows event trigger does not register with the TEO Server. This error message may be seen:
The RPC server is unavailable. (Exception from HRESULT: 0x800706BA)
Three WMI firewall rules must be enabled to allow passage through the firewall. This configuration should be performed on the TEO server.
Perform these steps for Windows 2008:
Click Start > Server Manager.
Go to Configuration > Windows Firewall > Inbound Rules.
In order to allow inbound of these components, right-click on them and allow enable of rule:
WMI (Async-In)
WMI (DCOM-In)
WMI (WMI-In)
Perform these steps for Windows 2003:
Click Start > Control Panel > Windows Firewall.
Click the Exceptions tab, choose the WMI check box, and click OK.
Revision | Publish Date | Comments |
---|---|---|
1.0 |
01-Mar-2011 |