This document provides the power specifications for the Cisco ONS 15454 Multiservice Provisioning Platform (MSPP).
There are no specific requirements for this document.
The information in this document is based on the Cisco ONS 15454 MSPP.
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.
Refer to Cisco Technical Tips Conventions for more information on document conventions.
Card | Approximate Power Consumption | Fiber Light Levels | |||
---|---|---|---|---|---|
AMPS | Watts | BTU per Hour | Rx Level | Tx Level | |
Max. Draw w/ Cards | 22.63 | 1088.64 | 3714.59 | ||
FAN TRAY: FTA2 | 1.21 | 58.00 | 198.00 | ||
FAN TRAY: FTA3-T | 1.98 | 95.00 | 324.00 | ||
XC | 0.28 | 13.00 | 46.00 | ||
XCVT | 0.72 | 34.40 | 117.46 | ||
XC10G | 1.64 | 78.60 | 268.40 | ||
TCC | 0.20 | 9.82 | 33.53 | ||
TCC+ | 0.20 | 9.82 | 33.53 | ||
AIC | 0.12 | 6.01 | 20.52 | ||
AIC-I | 0.17 | 8.00 | 27.30 | ||
DS1-14 | 0.26 | 12.60 | 43.02 | ||
DS1N-14 | 0.26 | 12.60 | 43.02 | ||
DS3-12E | 0.79 | 38.20 | 130.43 | ||
DS3N-12E | 0.79 | 38.20 | 130.43 | ||
DS3XM-6 | 0.42 | 20.00 | 68.00 | ||
EC1-12 | 0.76 | 36.60 | 124.97 | ||
E100T-G | 1.35 | 65.00 | 221.93 | ||
E1000-2-G incl. GBICs | 1.11 | 53.50 | 182.67 | ||
G1000-4 incl. GBICs | 1.31 | 63.00 | 215.11 | Max - Min | Max - Min |
OC3IR4-1310 | 0.40 | 13.20 | 65.56 | -8 to -28 | -8 to -15 |
OC12IR-1310 | 0.23 | 10.90 | 37.22 | -8 to -28 | -8 to -15 |
OC12LR-1310 | 0.25 | 9.28 | 41.00 | -8 to -28 | +2 to -3 |
OC12LR-1550 | 0.19 | 9.28 | 31.68 | -8 to -28 | +2 to -3 |
OC12IR4-1310 | 0.58 | 28.00 | 100.00 | -8 to -30 | -8 to -15 |
OC48IR-1310 High Speed | 0.67 | 32.20 | 109.94 | 0 to -18 | 0 to -5 |
OC48LR-1550 High Speed | 0.56 | 26.80 | 91.50 | -8 to -28 | +3 to -2 |
OC48IR-1310 Any Slot | 0.77 | 37.20 | 127.01 | 0 to -18 | 0 to -5 |
OC48LR-1550 Any Slot | 0.77 | 37.20 | 127.01 | -8 to -28 | +3 to -2 |
OC48ELR-ITU 100GHz | 0.65 | 31.20 | 106.53 | -9 to -27 | 0 to -2 |
OC48ELR-ITU 200GHz | 0.65 | 31.20 | 106.53 | -8 to -28 | 0 to -2 |
OC192LR-1550 | 1.50 | 72.20 | 246.52 | -10 to -19 | +10 to +7 |