Setting up a time range is useful if you want other features of the switch to be triggered or activated at a certain time. In addition, you can also specify how long a range can last for features that you want to disable after a period of time. Recurring time ranges can also be set if you want to continuously enable and disable a feature. Several of these features rely on time ranges to implement security or access control.
Time ranges can be defined and associated with the following types of commands:
There are two types of time ranges:
If a time range includes both absolute and recurring ranges, the operations of the associated commands are active only if both absolute start time and the recurring time range have been reached. Operations of the associated commands are inactive when either of the time ranges are reached.
This article provides instructions on how to configure time range settings on your switch.
Step 1. Log in to the web-based utility of your switch then choose Advanced in the Display Mode drop-down list.
Note: The available menu options may vary depending on the device model. In this example, SG350X-48MP is used.
Note: If you have an Sx300 or Sx500 Series switch, skip to Step 2.
Step 2. Choose Administration > Time Settings > Time Range.
Step 3. Click Add to add a new time range.
Step 4. Enter the time range name in the Time Range field. The range is from one to 32 characters.
Note: In this example, the time range name is Dayshift.
Step 5. In the Absolute Starting Time area, click a radio button to determine the starting point of the time range. The options are:
Note: In this example, the time range starts on January 1, 2017 at 8:00 in the morning.
Step 6. In the Absolute Ending Time area, click a radio button to determine the end time of the time range. The options are:
Note: In this example, the time range ends on December 31, 2017 at 17:00 in the afternoon.
Step 7. Click Apply then click Close.
Step 8. (Optional) Click Save to save settings to the startup configuration file.
Step 9. (Optional) To edit a time range, check the check box of the time range you wish to edit and click Edit.
Step 10. (Optional) To delete a time range, check the check box of the time range you wish to delete and click Delete.
Step 11. (Optional) To configure the recurring time range settings of the configured absolute time range, click the Recurring Range button then proceed to Step 2.
You should now have successfully configured the absolute time range settings on your switch.
A recurring time element can be added to an absolute time range. This limits the operation to certain time periods within the absolute range.
Step 1. In the web-based utility of your switch, choose Administration > Time Settings > Time Range.
Note: Alternatively, you can click the Recurring Range button in the Time Range page.
Step 2. Choose a time range name from the Time Range Name drop-down list.
Note: In this example, Dayshift is chosen.
Step 3. Click Go. The table will display any recurring ranges already configured for the chosen time range name.
Note: In this example, no recurring range is configured.
Step 4. Click Add to add a new recurring time range.
The Time Range Name area displays the time range that you are configuring.
Step 5. In the Recurring Starting Time area, use the drop-down lists to specify a day of the week and a time (in 24-hour format) that the time range begins on a recurring basis.
Note: In this example, the recurring time range starts every Monday at 8:00 in the morning.
Step 6. In the Recurring Ending Time area, use the drop-down lists to specify a day of the week and a time (in 24-hour format) that the time range ends on a recurring basis.
Note: In this example, the recurring time range ends every Friday at 17:00 in the afternoon.
Step 7. Click Apply then click Close.
Step 8. (Optional) Click Save to save settings to the startup configuration file.
Step 9. (Optional) To delete a recurring time range, check the check box of the time range you wish to delete and click Delete.
Step 10. (Optional) To configure a time range, click the Time Range button.
You should now have successfully configured the recurring time range settings on your switch.