This document shows how to replace a failed redundant supervisor module in Catalyst 6500 Series Switches. This document explains the procedure for the supervisor modules that run in Hybrid OS.
Cisco recommends that you have knowledge of these topics:
The information in this document is based on these software and hardware versions:
Cisco Catalyst 6500 Series Switch
Supervisor Module: WS-SUP32-GE-3B
Hybrid OS:
Catalyst OS (CatOS) 8.5(8)
MSFC IOSĀ® 12.2(18)SXF7
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.
This document can also be used with these hardware and software versions:
Supervisor 720 that runs Hybrid OS
Supervisor 2 that runs Hybrid OS
Refer to Cisco Technical Tips Conventions for more information on document conventions.
These are some of the important points related to redundant supervisor modules:
On the standby supervisor engine, the console port is inactive, the module status shows as "standby", and the status for the uplink ports is shown normally.
In order to allow you to control the booting of each supervisor engine separately, the configuration registers are not synchronized between the supervisor engines.
If the software versions of the two supervisor engines are different, or if the NVRAM configuration of the two supervisor engines is different, the active supervisor engine automatically downloads its software image and configuration to the standby supervisor engine.
The supervisor engines use two flash images: the boot image and the run-time image. The boot image filename, which is specified in the BOOT environment variable, is stored in NVRAM. The run-time image is the boot image that the ROM monitor uses to boot the supervisor engine. After the system boots, the run-time image resides in dynamic RAM (DRAM).
The redundant supervisor engines must be of the same type with the same model feature card. The WS-X6K-SUP1-2GE and the WS-X6K-SUP1A-2GE, which are both without Policy Feature Cards (PFCs), are compatible for redundancy. For supervisor engines with PFCs, the PFCs must be identical for redundancy (two PFCs, two PFC2s, two PFC3As, two PFC3Bs, or two PFC3BXLs).
This section provides the step by step procedure to replace the Supervisor Module 32 in a Catalyst 6500 Series Switch. This example uses a Cisco Catalyst 6509 Switch, which has two supervisor modules in slot 5 and 6. The supervisor module in slot 6 has failed. It is assumed that the failed supervisor module in slot 6 is removed from the chassis. You can see the procedure to add the new supervisor module into slot 6.
If you have an additional Cisco Catalyst 6500 Series Switch, you can connect the new supervisor on the switch and upgrade or downgrade the Hybrid OS to the same level as the supervisor in slot 5 of the production switch. If you have the same Hybrid OS in the new supervisor module, you do not need to configure anything on the new supervisor module. When you add the supervisor module into slot 6, the active supervisor engine automatically synchs the configuration. This section shows the step by step process and the checklist during the supervisor replacement.
This is the step by step procedure to replace the Supervisor Module 32 in a Catalyst 6500 Series Switch:
Add the supervisor module into slot 6.
If you have console connection to the supervisor at slot 6, you should see this output:
!--- Supervisor module at slot 6 System Bootstrap, Version 12.2(18r)SX2, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 2004 by cisco Systems, Inc. Cat6k-Sup32 platform with 524288 Kbytes of main memory Autoboot executing command: "boot bootdisk:cat6000-sup32pfc3k8.8-5-8.bin" Self decompressing the image : ############################################ ########################################################################### ########################################################################### ########################################################################### ########################################################################### ########################################################################### ########################################################################### ########################################################################### ########################################################################### ########################################################################### ########################################################################### ##################################################### [OK] System Power On Diagnostics DRAM Size ..........................512 MB Testing DRAM .......................Passed Verifying Text Segment .............Passed NVRAM Size .........................2048 KB Level2 Cache .......................Present Level3 Cache .......................Absent System Power On Diagnostics Complete Currently running ROMMON from S (Gold) region Boot image: bootdisk:cat6000-sup32pfc3k8.8-5-8.bin Firmware compiled 01-Dec-06 12:57 by integ Build [100] This module is now in standby mode. Console is disabled for standby supervisor.
This output shows the console of the active supervisor in slot 5:
Access2> (enable) Access2> (enable) Access2> (enable) 2007 May 22 19:17:48 %SYS-5-MOD_INSERT:Module 6 has been inserted Access2> (enable) Access2> (enable) Access2> (enable) %SYS-5-SUP_MODSBY:Module 6 is in standby mode %SYS-5-SUP_IMGSYNC:File synchronization process will start in 120 seconds %DIAG-6-RUN_MINIMUM:Module 6: Running Minimal Diagnostics... %DIAG-6-DIAG_OK:Module 6: Passed Online Diagnostics %SYS-3-TRANSCEIVER_NOTSUPP: Transceiver on port 6/1 is not supported %SYS-3-TRANSCEIVER_NOTSUPP: Transceiver on port 6/2 is not supported %SYS-5-PORT_SSUPOK:Ports on standby supervisor (module 6) are up %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 6 %DIAG-6-RUN_MINIMUM:Module 16: Running Minimal Diagnostics... %DIAG-6-DIAG_OK:Module 16: Passed Online Diagnostics %SYS-5-MOD_OK:Module 16(WS-F6K-MSFC2A,SAL1018LQ3C) is online %MGMT-5-SYS_CONFIG_START_MOD_FAIL:Unable to start system configuration for module 6 %MGMT-5-SYS_CONFIG_START_MOD_FAIL:Unable to start system configuration for module 16 %SYS-5-SUP_IMGSYNCSTART:Active supervisor is synchronizing bootdisk: cat6000-sup32pfc3k8.8-5-8.bin %SYS-5-SUP_IMGSYNCFINISH:Active supervisor has synchronized bootdisk: cat6000-sup32pfc3k8.8-5-8.bin Access2> (enable)
Verify the supervisor redundancy status:
Access2> (enable) show system highavailability Highavailability: enabled Highavailability versioning: disabled Highavailability Operational-status: ON Access2> (enable)
Verify the MSFC redundancy status:
Access2> (enable) session 15 Trying Router-15... Connected to Router-15. Escape character is '^]'. LAB-Router>enable LAB-Router#show redundancy Redundant System Information : ------------------------------ Available system uptime = 10 minutes Switchovers system experienced = 0 Standby failures = 0 Last switchover reason = unsupported Hardware Mode = Duplex Configured Redundancy Mode = Stateful SwitchOver - SSO Operating Redundancy Mode = Stateful SwitchOver - SSO Maintenance Mode = Disabled Communications = Up Current Processor Information : ------------------------------- Active Location = slot 5 Current Software state = ACTIVE Uptime in current state = 10 minutes Image Version = Cisco Internetwork Operating System Software IOS (tm) MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 01:03 by kellythw BOOT = CONFIG_FILE = BOOTLDR = Configuration register = 0x2102 Peer Processor Information : ---------------------------- Standby Location = slot 6 Current Software state = STANDBY HOT Uptime in current state = 2 minutes Image Version = Cisco Internetwork Operating System Software IOS (tm) MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 01:03 by kellythw BOOT = CONFIG_FILE = BOOTLDR = Configuration register = 0x2102 LAB-Router#
Force the supervisor failover and test:
!--- Supervisor in slot 5 Access2> (enable) switch supervisor This command will force a switch-over to the standby Supervisor module. Do you want to continue (y/n) [n]? y 2007 May 21 20:40:37 %SYS-5-MOD_RESET:Module 5 reset from Console// Access2> (enable) System Bootstrap, Version 12.2(18r)SX2, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 2004 by cisco Systems, Inc. Cat6k-Sup32 platform with 262144 Kbytes of main memory Autoboot executing command: "boot bootdisk:cat6000-sup32pfc3k8.8-5-8.bin" Self decompressing the image : ############################################## ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ##################################################### [OK] System Power On Diagnostics DRAM Size ..........................256 MB Testing DRAM .......................Passed Verifying Text Segment .............Passed NVRAM Size .........................2048 KB Level2 Cache .......................Present Level3 Cache .......................Absent System Power On Diagnostics Complete Currently running ROMMON from S (Gold) region Boot image: bootdisk:cat6000-sup32pfc3k8.8-5-8.bin Firmware compiled 01-Dec-06 12:57 by integ Build [100] This module is now in standby mode. Console is disabled for standby supervisor
Console into Supervisor 6 and verify the supervisor and MSFC configuration.
This section explains the step by step procedure to replace the Supervisor Module 32 in a Catalyst 6500 Series Switch. This example uses a Cisco Catalyst 6509 Switch which has two supervisor modules in slot 5 and 6. The supervisor module in slot 6 has failed. It is assumed that the failed supervisor module in slot 6 is removed from the chassis. You can see the procedure to add the new supervisor module into slot 6.
If you do not have an option to upgrade the new supervisor hybrid OS to the same version as the active supervisor, you can perform this procedure to add the supervisor module and synchronize the Hybrid OS and the switch configuration. Most of the procedure is automated. This document shows the step by step process and the checklist to be performed during the supervisor replacement.
This section shows you the show output of the switch without the supervisor in slot 6.
Show module
Show version
Boot variable
Show module output:
Access2> (enable) show module Mod Slot Ports Module-Type Model Sub Status --- ---- ----- ------------------------- ------------------- --- -------- 1 1 0 1000BaseX Ethernet no power-down 2 2 48 10/100BaseTX Ethernet WS-X6248-RJ-45 no ok 3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok 4 4 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok 5 5 9 1000BaseX Supervisor WS-SUP32-GE-3B yes ok 15 5 1 Multilayer Switch Feature WS-F6K-MSFC2A no ok 7 7 5 Communication Media Mod. WS-SVC-CMM no ok 8 8 0 FXS no power-down 9 9 0 10/100BaseTX Ethernet no power-down !--- Output suppressed Mod Sub-Type Sub-Model Sub-Serial Sub-Hw Sub-Sw --- ----------------------- ------------------- ----------- ------ ------ 3 Inline Power Module WS-F6K-VPWR 1.0 1.1(1) 4 Inline Power Module WS-F6K-VPWR 1.0 1.1(1) 5 L3 Switching Engine III WS-F6K-PFC3B SAL1012GREU 2.1 Access2> (enable)
Show version output:
Access2> (enable) show version WS-C6509 Software, Version NmpSW: 8.5(8) Copyright (c) 1995-2006 by Cisco Systems NMP S/W compiled on Dec 1 2006, 23:03:43 System Bootstrap Version: 12.2 System Boot Image File is 'bootdisk:cat6000-sup32pfc3k8.8-5-8.bin' System Configuration register is 0x2102 Hardware Version: 2.0 Model: WS-C6509 Serial #: SCA034500F5 PS1 Module: WS-CAC-6000W Serial #: AZS10130G7T Mod Port Model Serial # Versions --- ---- ------------------- ----------- -------------------------------------- 2 48 WS-X6248-RJ-45 SAD03431007 Hw : 1.1 Fw : 4.2(0.24)VAI78 Sw : 8.5(8) 3 48 WS-X6348-RJ-45 SAD04150A2T Hw : 1.1 Fw : 5.3(1) Sw : 8.5(8) WS-F6K-VPWR Hw : 1.0 Sw : 1.1(1) 4 48 WS-X6348-RJ-45 SAD05070CNX Hw : 2.0 Fw : 5.4(2) Sw : 8.5(8) WS-F6K-VPWR Hw : 1.0 Sw : 1.1(1) 5 9 WS-SUP32-GE-3B SAL1010F8KG Hw : 4.2 Fw : 12.2 Fw1: 8.5(8) Sw : 8.5(8) Sw1: 8.5(8) WS-F6K-PFC3B SAL1012GREU Hw : 2.1 Sw : 7 5 WS-SVC-CMM SAD100707YJ Hw : 2.8 Fw : 12.4(7a), Sw : 12.4(7a), 15 1 WS-F6K-MSFC2A SAL1012GG1X Hw : 3.0 Fw : 12.2(18)SXF7 Sw : 12.2(18)SXF7 DRAM FLASH NVRAM Module Total Used Free Total Used Free Total Used Free ------ ------- ------- ------- ------- ------- ------- ----- ----- ----- 5 262144K 124421K 137723K 249772K 9796K 239976K 2048K 366K 1682K Uptime is 0 day, 0 hour, 3 minutes Access2> (enable)
Boot variable:
!--- Current working directory Access2> (enable) pwd bootdisk !--- Files in the bootdisk Access2> (enable) dir 2 -rw- 10029260 Dec 13 2006 15:37:08 cat6000-sup32pfc3k8.8-5-8.bin 245735424 bytes available (10031104 bytes used) !--- Boot variable Access2> (enable) show boot BOOT variable = bootdisk:cat6000-sup32pfc3k8.8-5-8.bin,1; CONFIG_FILE variable = bootflash:switch.cfg Configuration register is 0x2102 ignore-config: disabled auto-config: non-recurring, overwrite, sync disabled ROMMON console baud: 9600 boot: image specified by the boot system commands Image auto sync is enabled Image auto sync timer is 120 seconds Access2> (enable)
The supervisor module is inserted into slot 6. The console output of the active and standby supervisor modules when you add the new standby supervisor module into the switch is shown here:
Insert the new supervisor module into slot 6.
You can see this log message in the active supervisor module:
Access2> (enable) 2007 May 21 20:21:14 %SYS-5-MOD_INSERT:Module 6 has been inserted
If you have consoled into the standby supervisor at 6, you can see this boot process:
System Bootstrap, Version 12.2(18r)SX2, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 2004 by cisco Systems, Inc. Cat6k-Sup32 platform with 524288 Kbytes of main memory Autoboot executing command: "boot bootdisk:cat6000-sup32pfc3k8.8-4-5.bin" Self decompressing the image : ############################################## ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ############################################################################# ######################################################################## [OK] System Power On Diagnostics DRAM Size ..........................512 MB Testing DRAM .......................Passed Verifying Text Segment .............Passed NVRAM Size .........................2048 KB Level2 Cache .......................Present Level3 Cache .......................Absent System Power On Diagnostics Complete Currently running ROMMON from S (Gold) region Boot image: bootdisk:cat6000-sup32pfc3k8.8-4-5.bin Firmware compiled 02-Aug-05 16:08 by integ Build [100] This module is now in standby mode. Console is disabled for standby supervisor
You can verify the redundancy status from the active supervisor module at slot 5.
Access2> (enable) 2007 May 21 20:23:09 %SYS-5-SUP_MODSBY:Module 6 is in standby mode 2007 May 21 20:23:11 %SYS-5-SUP_IMGSYNCSTART:Active supervisor is synchronizing bootdisk:cat6000-sup32pfc3k8.8-5-8.bin Access2> (enable) show system highavailability Highavailability: enabled Highavailability versioning: disabled Highavailability Operational-status: OFF(standby-supervisor-image-incompatible)
The active supervisor module copies the CatOS into the standby supervisor module. It also configures the boot variable of the standby supervisor engine to the new CatOS.
Access2> (enable) 2007 May 21 20:24:23 %SYS-5-SUP_IMGSYNCFINISH:Active superviso r has synchronized bootdisk:cat6000-sup32pfc3k8.8-5-8.bin
After the CatOS image is copied to the standby supervisor, the standby module 6 automatically reloads with the new image.
This module is now in standby mode. Console is disabled for standby supervisor System Bootstrap, Version 12.2(18r)SX2, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 2004 by cisco Systems, Inc. Cat6k-Sup32 platform with 524288 Kbytes of main memory Autoboot executing command: "boot bootdisk:RTSYNC_cat6000-sup32pfc3k8.8-5-8.bin" Self decompressing the image : ################################################# ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ##################################################### [OK] System Power On Diagnostics DRAM Size ..........................512 MB Testing DRAM .......................Passed Verifying Text Segment .............Passed NVRAM Size .........................2048 KB Level2 Cache .......................Present Level3 Cache .......................Absent System Power On Diagnostics Complete Currently running ROMMON from S (Gold) region Boot image: bootdisk:RTSYNC_cat6000-sup32pfc3k8.8-5-8.bin Firmware compiled 01-Dec-06 12:57 by integ Build [100] This module is now in standby mode. Console is disabled for standby supervisor
Once the standby module is up, you can verify the redundancy status from the active supervisor module.
Access2> (enable) 2007 May 21 20:26:22 %SYS-5-SUP_MODSBY:Module 6 is in standby mode 2007 May 21 20:26:23 %SYS-5-SUP_IMGSYNC:File synchronization process will start in 120 seconds 2007 May 21 20:27:08 %SYS-1-SYS_LCPERR1:Module 16: RP requested reset of peer RP : MSFC on module 16 will be reset 2007 May 21 20:27:24 %DIAG-6-RUN_MINIMUM:Module 6: Running Minimal Diagnostics.. . 2007 May 21 20:27:24 %DIAG-6-DIAG_OK:Module 6: Passed Online Diagnostics 2007 May 21 20:27:25 %SYS-3-TRANSCEIVER_NOTSUPP: Transceiver on port 6/1 is not supported 2007 May 21 20:27:25 %SYS-3-TRANSCEIVER_NOTSUPP: Transceiver on port 6/2 is not supported 2007 May 21 20:27:25 %SYS-5-PORT_SSUPOK:Ports on standby supervisor (module 6) a re up 2007 May 21 20:27:25 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 6 2007 May 21 20:28:24 %SYS-5-SUP_IMGSYNCSTART:Active supervisor is synchronizing bootdisk:cat6000-sup32pfc3k8.8-5-8.bin 2007 May 21 20:28:25 %SYS-5-SUP_IMGSYNCFINISH:Active supervisor has synchronized bootdisk:cat6000-sup32pfc3k8.8-5-8.bin Access2> (enable)
Access2> (enable) dir 2 -rw- 10029260 Dec 13 2006 15:37:08 cat6000-sup32pfc3k8.8-5-8.bin 245735424 bytes available (10031104 bytes used) Access2> (enable) dir 6/ 2 -rw- 9356096 May 11 2006 19:04:09 cat6000-sup32pfc3k8.8-4-5.bin 2287 -rw- 10029260 May 21 2007 20:24:10 RTSYNC_cat6000-sup32pfc3k8.8-5- 8.bin !--- You can see the copied CatOS name starts with RTSYNC_ 236900352 bytes available (19390464 bytes used) Access2> (enable) show system highavailability Highavailability: enabled Highavailability versioning: disabled Highavailability Operational-status: ON
Perform these steps:
Show module output:
Access2> (enable) show module Mod Slot Ports Module-Type Model Sub Status --- ---- ----- ------------------------- ------------------- --- -------- 1 1 0 1000BaseX Ethernet no power-down 2 2 48 10/100BaseTX Ethernet WS-X6248-RJ-45 no ok 3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok 4 4 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok 5 5 9 1000BaseX Supervisor WS-SUP32-GE-3B yes ok 15 5 1 Multilayer Switch Feature WS-F6K-MSFC2A no ok 6 6 9 1000BaseX Supervisor WS-SUP32-GE-3B yes standby 7 7 5 Communication Media Mod. WS-SVC-CMM no ok 8 8 0 FXS no power-down 9 9 0 10/100BaseTX Ethernet no power-down !--- Output suppressed Mod Sub-Type Sub-Model Sub-Serial Sub-Hw Sub-Sw --- ----------------------- ------------------- ----------- ------ ------ 3 Inline Power Module WS-F6K-VPWR 1.0 1.1(1) 4 Inline Power Module WS-F6K-VPWR 1.0 1.1(1) 5 L3 Switching Engine III WS-F6K-PFC3B SAL1012GREU 2.1 6 L3 Switching Engine III WS-F6K-PFC3B SAL1017L9WJ 2.1
Verify redundancy-history:
Access2> (enable) show system redundancy-history Maximum entries of switchover history table = 10 System cold start due to switchover failure = 4 Standby available time (secs*100) = 33291 Redundant History Switchover Table:
The CatOS is copied automatically during the SYNC process. However, IOS at the MSFC is not copied automatically.
Verify the IOS and redundancy of the MSFC:
!--- 1. Connect to MSFC Access2> (enable) session 15 Trying Router-15... Connected to Router-15. Escape character is '^]'. LAB-Router>enable !--- 2. Verify the IOS file in the bootflash LAB-Router#dir Directory of bootflash:/ 1 -rwx 17966324 Dec 13 2006 15:12:29 +00:00 c6msfc2a-adventerprisek9_w an-mz.122-18.SXF7.bin 65536000 bytes total (47569548 bytes free) !--- 3. Show version output LAB-Router#show version Cisco Internetwork Operating System Software IOS (tm) MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 01:03 by kellythw Image text-base: 0x40101040, data-base: 0x42638000 ROM: System Bootstrap, Version 12.2(17r)SX3, RELEASE SOFTWARE (fc1) BOOTLDR: MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) LAB-Router uptime is 26 minutes System returned to ROM by power-on System image file is "bootflash:c6msfc2a-adventerprisek9_wan-mz.122-18.SXF7.bin" !--- 4. MSFC redundancy status LAB-Router#show redundancy Redundant System Information : ------------------------------ Available system uptime = 4 minutes Switchovers system experienced = 0 Standby failures = 0 Last switchover reason = unsupported Hardware Mode = Duplex Configured Redundancy Mode = Stateful SwitchOver - SSO Operating Redundancy Mode = Route Processor Redundancy !--- It is running in the RPR mode because the standby MSFC !--- is running different version of IOS. Maintenance Mode = Disabled Communications = Up Current Processor Information : ------------------------------- Active Location = slot 5 Current Software state = ACTIVE Uptime in current state = 4 minutes Image Version = Cisco Internetwork Operating System Software IOS (tm) MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 01:03 by kellythw BOOT = CONFIG_FILE = BOOTLDR = Configuration register = 0x2102 Peer Processor Information : ---------------------------- Standby Location = slot 6 Current Software state = STANDBY COLD Uptime in current state = 2 minutes Image Version = Cisco Internetwork Operating System Software IOS (tm) MSFC2A Software (C6MSFC2A-IPBASE_WAN-M), Version 12.2(18)SXF4, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Mar-06 14:53 by tinhuang BOOT = CONFIG_FILE = BOOTLDR = Configuration register = 0x2102 !--- Note that the boot variable is blank. The MSFC boots the !--- first IOS image in the bootflash: LAB-Router# LAB-Router#exit Access2> (enable)
Upgrade the IOS on the standby MSFC.
Copy the IOS image to the standby MSFC:
LAB-Router#copy c6msfc2a-adventerprisek9_wan-mz.122-18.SXF7.bin slavebootflash:/ Destination filename [c6msfc2a-adventerprisek9_wan-mz.122-18.SXF7.bin]? Copy in progress...CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC 17966324 bytes copied in 44.180 secs (406662 bytes/sec) LAB-Router# !--- Delete the old IOS image. Because the boot variable is blank !--- and the MSFC boots the first IOS image in the bootflash: LAB-Router#cd slavebootflash: LAB-Router#delete c6msfc2a-ipbase_wan-mz.122-18.SXF4.bin Delete filename [c6msfc2a-ipbase_wan-mz.122-18.SXF4.bin]? Delete slavebootflash:c6msfc2a-ipbase_wan-mz.122-18.SXF4.bin? [confirm] LAB-Router#
Reload the standby supervisor module:
LAB-Router#exit Access2> (enable) reset 6 This command will reset module 6. Do you want to continue (y/n) [n]? y 2007 May 21 21:14:03 %SYS-5-MOD_RESET:Module 6 reset from Console// Resetting module 6... Access2> (enable) show system highavailability Highavailability: enabled Highavailability versioning: disabled Highavailability Operational-status: OFF(standby-supervisor-not-present) Access2> (enable) 2007 May 21 21:16:01 %SYS-5-SUP_MODSBY:Module 6 is in standby mode 2007 May 21 21:16:02 %SYS-5-SUP_IMGSYNC:File synchronization process will start in 120 seconds 2007 May 21 21:16:03 %DIAG-6-RUN_MINIMUM:Module 6: Running Minimal Diagnostics.. . 2007 May 21 21:16:05 %DIAG-6-DIAG_OK:Module 6: Passed Online Diagnostics 2007 May 21 21:16:06 %SYS-3-TRANSCEIVER_NOTSUPP: Transceiver on port 6/1 is not supported 2007 May 21 21:16:06 %SYS-3-TRANSCEIVER_NOTSUPP: Transceiver on port 6/2 is not supported 2007 May 21 21:16:06 %SYS-5-PORT_SSUPOK:Ports on standby supervisor (module 6) are up 2007 May 21 21:16:07 %SYS-3-MOD_PORTINTFINSYNC:Port Interface in sync for Module 6 2007 May 21 21:16:49 %SYS-1-SYS_LCPERR1:Module 16: RP requeste d reset of peer RP: MSFC on module 16 will be reset Access2> (enable) show system highavailability Highavailability: enabled Highavailability versioning: disabled Highavailability Operational-status: ON Access2> (enable)
Verify the MSFC IOS after the upgrade:
Access2> (enable) session 15 Trying Router-15... Connected to Router-15. Escape character is '^]'. LAB-Router>enable LAB-Router#show redundancy Redundant System Information : ------------------------------ Available system uptime = 17 minutes Switchovers system experienced = 0 Standby failures = 1 Last switchover reason = unsupported Hardware Mode = Duplex Configured Redundancy Mode = Stateful SwitchOver - SSO Operating Redundancy Mode = Stateful SwitchOver - SSO Maintenance Mode = Disabled Communications = Up Current Processor Information : ------------------------------- Active Location = slot 5 Current Software state = ACTIVE Uptime in current state = 17 minutes Image Version = Cisco Internetwork Operating System Software IOS (tm) MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 01:03 by kellythw BOOT = CONFIG_FILE = BOOTLDR = Configuration register = 0x2102 Peer Processor Information : ---------------------------- Standby Location = slot 6 Current Software state = STANDBY HOT Uptime in current state = 0 minutes Image Version = Cisco Internetwork Operating System Software IOS (tm) MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 01:03 by kellythw BOOT = CONFIG_FILE = BOOTLDR = Configuration register = 0x2102 LAB-Router#
Now, you can failover the supervisor module to the newly added standby supervisor module and test it.
Failover the supervisor module:
Access2> (enable) switch supervisor This command will force a switch-over to the standby Supervisor module. Do you want to continue (y/n) [n]? y 2007 May 21 20:40:37 %SYS-5-MOD_RESET:Module 5 reset from Console// Access2> (enable) System Bootstrap, Version 12.2(18r)SX2, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 2004 by cisco Systems, Inc. Cat6k-Sup32 platform with 262144 Kbytes of main memory Autoboot executing command: "boot bootdisk:cat6000-sup32pfc3k8.8-5-8.bin" Self decompressing the image : ################################################# ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ################################################################################ ##################################################### [OK] System Power On Diagnostics DRAM Size ..........................256 MB Testing DRAM .......................Passed Verifying Text Segment .............Passed NVRAM Size .........................2048 KB Level2 Cache .......................Present Level3 Cache .......................Absent System Power On Diagnostics Complete Currently running ROMMON from S (Gold) region Boot image: bootdisk:cat6000-sup32pfc3k8.8-5-8.bin Firmware compiled 01-Dec-06 12:57 by integ Build [100] This module is now in standby mode. Console is disabled for standby supervisor
Console into Supervisor 6, which is the active module now.
Redundancy status:
Access2> (enable) show system highavailability Highavailability: enabled Highavailability versioning: disabled Highavailability Operational-status: ON Access2> (enable) show system redundancy-history Maximum entries of switchover history table = 10 System cold start due to switchover failure = 4 Standby available time (secs*100) = 98984 Redundant History Switchover Table: Index: 1 Previous active supervisor module: 5 Current active supervisor module : 6 Switchover reason : user initiated Switchover time : Mon May 21 2007, 20:40:37
Show version:
Access2> (enable) show version WS-C6509 Software, Version NmpSW: 8.5(8) Copyright (c) 1995-2006 by Cisco Systems NMP S/W compiled on Dec 1 2006, 23:03:43 System Bootstrap Version: 12.2 System Boot Image File is 'bootdisk:RTSYNC_cat6000-sup32pfc3k8.8-5-8.bin' System Configuration register is 0x2102
Boot variable:
Access2> (enable) show boot BOOT variable = bootdisk:RTSYNC_cat6000-sup32pfc3k8.8-5-8.bin,1;bootdisk:cat6000 -sup32pfc3k8.8-4-5.bin,1; CONFIG_FILE variable = bootdisk:switch.cfg Configuration register is 0x2102 ignore-config: disabled auto-config: non-recurring, overwrite, sync disabled ROMMON console baud: 9600 boot: image specified by the boot system commands Image auto sync is enabled Image auto sync timer is 120 seconds
Show module:
Access2> (enable) show module Mod Slot Ports Module-Type Model Sub Status --- ---- ----- ------------------------- ------------------- --- -------- 1 1 Unknown Card power-down 2 2 48 10/100BaseTX Ethernet WS-X6248-RJ-45 no ok 3 3 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok 4 4 48 10/100BaseTX Ethernet WS-X6348-RJ-45 yes ok 5 5 9 1000BaseX Supervisor WS-SUP32-GE-3B yes standby 6 6 9 1000BaseX Supervisor WS-SUP32-GE-3B yes ok 16 6 1 Multilayer Switch Feature WS-F6K-MSFC2A no ok 7 7 5 Communication Media Mod. WS-SVC-CMM no ok 8 8 0 FXS no power-down 9 9 Unknown Card power-down !--- Output suppressed Mod Sub-Type Sub-Model Sub-Serial Sub-Hw Sub-Sw --- ----------------------- ------------------- ----------- ------ ------ 3 Inline Power Module WS-F6K-VPWR 1.0 1.1(1) 4 Inline Power Module WS-F6K-VPWR 1.0 1.1(1) 5 L3 Switching Engine III WS-F6K-PFC3B SAL1012GREU 2.1 6 L3 Switching Engine III WS-F6K-PFC3B SAL1017L9WJ 2.1 Access2> (enable)
Verify the MSFC:
Access2> (enable) session 16 Trying Router-16... Connected to Router-16. Escape character is '^]'. LAB-Router>enable LAB-Router#show version Cisco Internetwork Operating System Software IOS (tm) MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2006 by cisco Systems, Inc. Compiled Thu 23-Nov-06 01:03 by kellythw Image text-base: 0x40101040, data-base: 0x42638000 ROM: System Bootstrap, Version 12.2(17r)SX3, RELEASE SOFTWARE (fc1) BOOTLDR: MSFC2A Software (C6MSFC2A-ADVENTERPRISEK9_WAN-M), Version 12.2(18)SXF7, RELEASE SOFTWARE (fc1) LAB-Router uptime is 7 minutes System returned to ROM by Stateful Switchover System image file is "bootflash:c6msfc2a-adventerprisek9_wan-mz.122-18.SXF7.bin" This product contains cryptographic features and is subject to United States and local country laws governing import, export, transfer and use. Delivery of Cisco cryptographic products does not imply third-party authority to import, export, distribute or use encryption. Importers, exporters, distributors and users are responsible for compliance with U.S. and local country laws. By using this product you agree to comply with applicable laws and regulations. If you are unable to comply with U.S. and local laws, return this product immediately. A summary of U.S. laws governing Cisco cryptographic products may be found at: http://www.cisco.com/wwl/export/crypto/tool/stqrg.html If you require further assistance please contact us by sending email to export@cisco.com. cisco MSFC2A (R7000) processor (revision MSFC2A) with 458752K/65536K bytes of me mory. Processor board ID MSFC2A R7000 CPU at 300Mhz, Implementation 0x27, Rev 3.3, 256KB L2, 1024KB L3 Cache Last reset from power-on SuperLAT software (copyright 1990 by Meridian Technology Corp). X.25 software, Version 3.0.0. Bridging software. TN3270 Emulation software. 29 Virtual Ethernet/IEEE 802.3 interfaces 509K bytes of non-volatile configuration memory. 65536K bytes of Flash internal SIMM (Sector size 512K). Configuration register is 0x2102
You can see that the CatOS name in the replaced supervisor module starts with RTSYNC. You can leave the system to run as it is. You can also change the file name and keep it as a standard name as shown here:
Access2> (enable) rename RTSYNC_cat6000-sup32pfc3k8.8-5-8.bin cat6000-sup32pfc3k 8.8-5-8.bin Access2> (enable) dir 2287 -rw- 10029260 May 21 2007 21:40:01 cat6000-sup32pfc3k8.8-5-8.bin 236900352 bytes available (19390464 bytes used) Access2> (enable)
After you rename the file, you must change the boot variable.
!--- Verify boot variable Access2> (enable) show boot BOOT variable = bootdisk:RTSYNC_cat6000-sup32pfc3k8.8-5-8.bin,1;bootdisk:cat6000 -sup32pfc3k8.8-4-5.bin,1; CONFIG_FILE variable = bootdisk:switch.cfg Configuration register is 0x2102 ignore-config: disabled auto-config: non-recurring, overwrite, sync disabled ROMMON console baud: 9600 boot: image specified by the boot system commands Image auto sync is enabled Image auto sync timer is 120 seconds !--- Clear all the boot variables Access2> (enable) clear boot system all BOOT variable = Access2> (enable) 2007 May 21 21:41:56 %SYS-5-SUP_IMGSYNC:File synchronization p rocess will start in 120 seconds !--- Configure the boot variable Access2> (enable) set boot system flash bootdisk:cat6000-sup32pfc3k8.8-5-8.bin BOOT variable = bootdisk:cat6000-sup32pfc3k8.8-5-8.bin,1; Access2> (enable) 2007 May 21 21:42:14 %SYS-5-SUP_IMGSYNC:File synchronization p rocess will start in 120 seconds !--- Verify the boot variable Access2> (enable) show boot BOOT variable = bootdisk:cat6000-sup32pfc3k8.8-5-8.bin,1; CONFIG_FILE variable = bootdisk:switch.cfg Configuration register is 0x2102 ignore-config: disabled auto-config: non-recurring, overwrite, sync disabled ROMMON console baud: 9600 boot: image specified by the boot system commands Image auto sync is enabled Image auto sync timer is 120 seconds
Revision | Publish Date | Comments |
---|---|---|
1.0 |
22-May-2007 |
Initial Release |