The show controllers e1 command displays the controller state that is specific to controller hardware. The information it displays is generally useful for diagnostic tasks.
There are no specific requirements for this document.
This document is not restricted to specific software and hardware versions.
For more information on document conventions, see the Cisco Technical Tips Conventions.
In order to explain the information generated when we use the show controllers e1 command, let's look at some sample output:
Bru#show controllers e1 E1 0 is up. Applique type is Channelized E1 - balanced No alarms detected. Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2 Manufacture Cookie is not programmed. Framing is CRC4, Line Code is HDB3, Clock Source is Line Primary. Data in current interval (251 seconds elapsed): 0 Line Code Violations, 0 Path Code Violations 0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs Total Data (last 24 hours) 0 Line Code Violations, 0 Path Code Violations, 0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins, 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs E1 1 is down. Applique type is Channelized E1 - balanced Transmitter is sending remote alarm. Receiver has loss of signal. Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2 Manufacture Cookie is not programmed. Framing is CRC4, Line Code is HDB3, Clock Source is Line Secondary. Data in current interval (200 seconds elapsed): 0 Line Code Violations, 0 Path Code Violations 0 Slip Secs, 200 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 200 Unavail Secs Total Data (last 24 hours) 0 Line Code Violations, 0 Path Code Violations, 0 Slip Secs, 86400 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins, 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 86400 Unavail Secs E1 2 is administratively down. Applique type is Channelized E1 - balanced Transmitter is sending remote alarm. Receiver has loss of signal. Version info of Slot 0: HW: 2, Firmware: 4, PLD Rev: 2 Manufacture Cookie is not programmed. Framing is CRC4, Line Code is HDB3, Clock Source is Internal. Data in current interval (249 seconds elapsed): 0 Line Code Violations, 0 Path Code Violations 0 Slip Secs, 249 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 249 Unavail Secs Total Data (last 24 hours) 0 Line Code Violations, 0 Path Code Violations, 0 Slip Secs, 86400 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins, 0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 86400 Unavail Secs
Let's look at what the data shown in this output means. Each field and its definition is explained in the table below:
Field | Description |
---|---|
E1 0 is up | Shows that the E1 controller 0 is operating. The controller's state can be up, down, or administratively down. Loopback conditions are shown as locally looped or remotely looped. |
Applique Type | Shows the hardware applique type and indicates whether it is balanced or unbalanced. |
Framing | Shows the current framing type. The default framing for E1 is cyclic redundancy check 4 (CRC4). |
Line Code | Shows the current line code. The default line coding for E1 is HDB3. |
No alarms detected | Any alarms detected by the controller are displayed here. The possible alarms are:
|
Data in current interval (251 seconds elapsed) | Shows the current accumulation period, which rolls into a 24 hour accumulation every 15 minutes. The accumulation period is from one to 900 seconds. The oldest 15-minute period falls off the back of the 24-hour accumulation buffer. |
Line Code Violations | Indicates the occurrence of either a Bipolar Violation (BPV) or Excessive Zeros (EXZ) error event. |
Path Code Violations | Indicates a frame synchronization bit error in the D4 and E1-no CRC formats, or a CRC error in the Extended Superframe (ESF) and E1-CRC formats. |
Slip secs | Indicates the replication or deletion of the payload bits of a domestic trunk interface (DS1) frame. A slip might happen when there is a difference between the timing of a synchronous receiving terminal and the received signal. |
Fr loss secs | Indicates the number of seconds an Out of Frame (OOF) error is detected. |
Line Err secs | Line Errored Seconds (LES) is a second in which one or more Line Code Violation errors are detected. |
Degraded mins | A degraded minute is one in which the estimated error rate exceeds 1E-6 but does not exceed 1E-3. |
Errored secs | In ESF and E1 CRC links, an errored second is a second in which one of the following defects is detected:
|
Bursty Err secs | A second with more than one but fewer than 320 Path Coding Violation errors, no Severely Errored Frame defects and no detected incoming AIS defects. Controlled slips are not included in this parameter. |
Severly Err secs | For ESF signals, this is a second in which one of the following defects is detected:
|
Unavail Secs | A count of the total number of seconds on the interface. This field is calculated by counting the number of seconds that the interface is unavailable. |