The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This appendix provides hardware specifications for the WAVE-574 appliance. It contains the following sections:
Table A-1 provides a summary of the features and specifications of the WAVE-574.
|
|
---|---|
Microprocessor |
•1 Intel Xeon Quad-Core Processor X3220, or •2.4 GHz •8 MB Level 2 cache •1066-MHz front-side bus (FSB) |
Memory |
•3 GB (optionally 6 GB) ECC DDR2 SDRAM |
Drives standard |
•DVD-ROM/CD-RW combination drive •RAID-1 array with two 500-GB SATA hard disk drives |
Fans |
•4 dual-rotor fans |
Expansion slots |
•2 PCI Express ×8 (1 @ ×8, 1 @ ×1 speed) |
Size |
•Height: 4.32 cm (1.70 in.) •Depth: 68.20 cm (26.85 in.) •Width: 44.80 cm (17.64 in.) |
Weight |
11.79 kg (26.0 lb) to 15.20 kg (33.50 lb) depending upon configuration |
Electrical Input Requirements1 |
•Range Line Voltage: 90 to 132 VAC, 180 to 264 VAC •Rated Input Current: 6 A (at 100 VAC), 3 A (at 200 VAC) •Rated Input Frequency: 47 to 63 Hz •Rated Input Power: 486 W (at 100 VAC), 479 W (at 200 VAC) |
BTU Rating |
•1836 BTU/hr (100 VAC) •1706 BTU/hr (200 VAC) |
Power supply output |
•Rated steady-state power: –400 W (100 VAC) –400 W (200 VAC) •Maximum peak power: –400 W (100 VAC) –400 W (200 VAC) |
Acoustic noise2 |
•Idle: –LWAd -6.30 B –LpAm -52.07 dB •Operating: –LWAd -6.38 B –LpAm -52.77 dB |
Environment |
•Air temperature: –Operating3 : 10 to 35 °C (50 to 95 °F) –Non-operating: -30 to 60 °C (-22 to 140 °F) •Maximum rate of temperature change: –Operating4 , 5 : 10 °C/hr (18 °F/hr) –Non-operating: 20 °C/hr (36 °F/hr) •Humidity: –Operating: 10% to 90% –Nonoperating: 5% to 95% •Maximum wet bulb temperature (noncondensing): –Operating: 28 °C (82.4 °F) –Nonoperating: 38.7 °C (101.7 °F) •Altitude: –Operating: 3,050 m (10,000 ft) –Nonoperating: 9144 m (30,000 ft) •Maximum rate of altitude change: –Operating: 457 m/min (1,500 ft/min) –Nonoperating: 457 m/min (1,500 ft/min) |
1 The limits apply when operated in an ambient environment temperature of +23.0°C ± 2° (+73.4°F ± 2°). 2 Average A-Weighted sound power levels (LWAd) and average bystander position A-Weighted sound pressure levels (LpAm) in a 23°C ambient environment, measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Acoustic noise levels are maximum measurements with four fans installed. 3 All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 2000 m (6500 ft) is applicable. No direct sunlight allowed. 4 The type and number of options installed can limit the upper limit. 5 System performance may be reduced if operating with a fan fault above 30ºC (86ºF). |
Table A-2 describes the inline network adapter technical and general specifications.