System Message Guide for Cisco IOS XE 17.16.x

Cisco System Messages Overview

This document describes system messages for Cisco software releases. During operation, the system software sends these messages to the console (and, optionally, to a logging server on another system) during operation. Not all system messages indicate problems with your system. Some are purely informational, and others may help diagnose problems with communications lines, internal hardware, or the system software.

How To Read System Error Messages

System error messages begin with a percent sign (%) and are structured as follows:%FACILITY-SUBFACILITY-SEVERITY-MNEMONIC: Message-text

  • FACILITY is a code consisting of two or more uppercase letters that indicate the facility to which the message refers. A facility can be a hardware device, a protocol, or a module of the system software.

  • SEVERITY is a single-digit code from 0 to 7 that reflects the severity of the condition. The lower the number, the more serious the situation. Table 1 lists the severity levels.

  • MNEMONIC is a code that uniquely identifies the error message.

  • Message-text is a text string describing the condition. This portion of the message sometimes contains detailed information about the event, including terminal port numbers, network addresses, or addresses that correspond to locations in the system memory address space. Because the information in these variable fields changes from message to message, it is represented here by short strings enclosed in square brackets ([ ]). A decimal number, for example, is represented as [dec]. Table 2 lists the representations of variable fields and the type of information in them.

The following is a sample system error message:

%LINK-2-BADVCALL: Interface [chars], undefined entry point

Some error messages also indicate the card and slot reporting the error. These error messages begin with a percent sign (%) and are structured as follows:

%CARD-SEVERITY-MSG:SLOT %FACILITY-SEVERITY-MNEMONIC: Message-text

  • CARD is a code that describes the type of card reporting the error. VIP and FEIP are possible card types.

  • MSG is a mnemonic that indicates that this is a message. It is always shown as MSG.

  • SLOT indicates the slot number of the card reporting the error. It is shown as SLOT followed by a number (for example, SLOT5).

The prepended portion of the error message (%CARD-SEVERITY-MSG:SLOT) is not shown in the error message listings in this document.

Error Message Severity Levels

Error message severity levels correspond to the keywords assigned by the logging global configuration commands that define where and at what level these messages appear. The default is to log messages to the console at the debugging level (7). For more information, see the system configuration chapter and descriptions of the logging command in the configuration guide and command reference.

Level

Description

0 - emergency

System unusable

1 - alert

Immediate action needed

2 - critical

Critical condition

3 - error

Error condition

4 - warning

Warning condition

5 - notification

Normal, but significant, condition

6 - informational

Informational message only

7 - debugging

Appears during debugging only

Representation of Variable Fields in Error Messages

Representation

Type of Information

[atalk_address]

AppleTalk address

[atalk_net]

AppleTalk network, either 600 or 600-601

[char]

Single character

[chars]

Character string

[dec]

Decimal number

[enet]

Ethernet address (for example, 0000.FEED.00C0)

[hex]

Hexadecimal number

[inet]

Internet address (for example, 10.0.2.16)

[int]

Integer number

[node]

Address or node name

[sci_notation]

Scientific notation

[t-line]

Terminal line number in octal (or decimal if the decimal-TTY service is enabled)

[v-name]

VINES name; or number (hex or decimal)

Error Message Traceback Reports

Some messages describe internal errors and contain traceback information. This information is very important and should be included when you report a problem to your technical support representative.

The following sample message includes traceback information:

-Process= "Exec", level= 0, pid= 17 -Traceback= 1A82 1AB4 6378 A072 1054 1860

System and Error Messages in Cisco IOS XE 17.16.x

The following tables list system and error messages and recommended actions. Scroll right to see the Recommendation Action. Alternatively, you can download the system and error messages in the excel format here: System Message Guide for Cisco IOS XE 17.16.x.

A to E

Facility-Severity-Mnemonic

Severity-Meaning

Message

Message-Explanation

Component

Recommended-Action

AAA_AUDIT_MESSAGE-6-METHOD_LIST_STATE

6-Information

mlist [chars] of [chars] service is marked for notifying state and its current state is : [chars]

Method list state change

polaris-aaa

LOG_STD_NO_ACTION

AAA_AUDIT_MESSAGE-6-NOTIFY_MLIST_STATE_TO_AAA_CLIENT

6-Information

Notifying state of [chars] method list [chars] of [chars] service as [chars]

Method list state change notified to AAA CLIENT

polaris-aaa

LOG_STD_NO_ACTION

ACCESS_SESSION_TRACE-3-TRACE_INIT_FAIL

3-Error

Access session trace initialization failed with code: [dec].

Failed to initialize access-session trace.

polaris-smd

Review smd logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log.

ACCESS_SESSION_TRACE-3-TRACE_REG_FAIL

3-Error

Component [chars] registration failed. Error code: [dec]

Component failed to register with access-session trace

polaris-smd

Review smd logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log.

ACLMGR_MESSAGE-3-ACL_LEN_ERR

3-Error

Error in [chars]

ewlc ACL flex push error message.

iosxe-binos-utils

LOG_STD_ACTION

ACL_ERRMSG-3-CHANGE_ERROR

3-Error

[chars] [chars] [chars] ACL [chars] change configuration could not be updated on all installed interfaces.\n

The given ACL change configuration could not be applied to all installed policies in hardware.

INVALID

Find out more about the error by using the show platform software trace messages fed command.

ACL_ERRMSG-3-ERROR

3-Error

[chars] [chars] [chars] ACL [chars] configuration could not be applied on [chars].\n

The given ACL configuration could not be applied to hardware.

INVALID

Find out more about the error by using the show platform software trace messages fed command.

ACL_ERRMSG-3-SGACL_ERROR

3-Error

SGACL configuration could not be changed on [chars].\n

An error occurred during SGACL configuration change, all SGACLs have been removed from cell.

INVALID

User needs to manually remove the cell configuration and attempt to re-apply when resources have been freed.

ACL_ERRMSG-4-ACLTCAM_FULL

4-Warning

[chars] [chars] [chars] ACL on [chars] could not be programmed in hardware, ACL TCAM is full.\n

The configuration is too large.

INVALID

You have exceeded the system limit of ACL TCAM, use a simpler configuration which uses less ACL entries.\n

ACL_ERRMSG-4-DGT_FULL

4-Warning

[chars] [chars] [chars] ACL on [chars] could not be programmed in hardware, DGT ID table is full.\n

The configuration is too large.

INVALID

You have exceeded the system limit of DGT, use a simpler configuration which uses less DGT entries.\n

ACL_ERRMSG-4-HASH_ERROR

4-Warning

[chars] [chars] [chars] ACL on cell [chars] could not be found.\n

The configuration is unknown.

INVALID

There is no SGACL Cell with this configuration found.\n

ACL_ERRMSG-4-HASH_FULL

4-Warning

[chars] [chars] [chars] ACL on cell [chars] could not be programmed in hardware, SGACL table is full.\n

The configuration is too large.

INVALID

You have exceeded the system limit of SGACL cells, use a simpler configuration which uses less SGACL cells.\n

ACL_ERRMSG-4-HASH_ZERO

4-Warning

[chars] [chars] [chars] ACL on cell [chars] could not be programmed in hardware, sgt or mpls-vpn hash size is zero.\n

Cannot configure in hardware due to zero sgt or mpls-vpn hash entries.

INVALID

Allocate hash entries to sgt or mpls-vpn using custom template.\n

ACL_ERRMSG-4-POLICYLABEL_FULL

4-Warning

[chars] [chars] [chars] ACL on [chars] could not be programmed in hardware, Policy Label table is full.\n

The configuration is too large.

INVALID

You have exceeded the system limit of the number of Policies, use a simpler configuration which uses less Policy entries.\n

ACL_ERRMSG-4-PROGRAM_FAILED

4-Warning

[chars] [chars] [chars] ACL on [chars] programming failed in hardware.\n

The configuration is too large.

INVALID

You have exceeded the system limit of entries, use a simpler configuration which uses less entries.\n

ACL_ERRMSG-4-SIS_STATS_FULL

4-Warning

Policy id [dec] could not be programmed in hardware, SIS stats table is FULL.\n

The configuration is too large.

INVALID

You have exceeded the system limit of hardware resources, use a simpler configuration which uses less resources.\n

ACL_ERRMSG-4-UNLOADED

4-Warning

[chars] [chars] [chars] ACL on interface [chars] could not be programmed in hardware and traffic will be dropped.\n

The configuration is too large; dropped will be dropped on this interface.

INVALID

Allocate more space to the relevant section of the TCAM and reboot, or else use a simpler configuration. If possible, use the same ACLs on multiple interfaces.\n

ACL_ERRMSG-6-GACL_INFO

6-Information

Logging is not supported for GACL.\n

The ACL logging is not supported for client/group ACL.

INVALID

No action is needed.

ACL_ERRMSG-6-PACL_INFO

6-Information

Logging is not supported for PACL.\n

The ACL logging is not supported on port interface.

INVALID

No action is needed.

ACL_ERRMSG-6-RELOADED

6-Information

[chars] [chars] [chars] ACL on interface [chars] has now been loaded into the hardware.\n

The configuration that previously was unable to fit into the hardware will now fit and has been programmed for this interface.

INVALID

No action required, informational only.\n

ACL_ERRMSG-6-REMOVED

6-Information

The [chars] [chars] [chars] ACL configuration that was previously unloaded has been removed from interface [chars].\n

The configuration that was previously unloaded, because of lack of space, has been removed.

INVALID

No action required, informational only.

ACL_ERRMSG-6-THRESHOLD_EVENT

6-Information

The [chars] threshold alarm state is [chars] for switch [dec] asic [dec]; with [dec] entries used and [dec] entries remaining.\n

The configuration exceeds the threshold, because of lack of space.

INVALID

No action required, informational only.

ADMINTECH-3-INCOMPLETE_BUNDLE

3-Error

Admin-tech bundle is incomplete, IOS tech-support timed out after [dec] seconds

This syslog is generated IOS tech-support times out resulting into incomplete admin-tech. Default timeout for admin-tech is 30 mins, however on loaded systems, this timeout might not be sufficient and admin-tech could potentially time out

cedge-admintech

Increase the timeout value for admin-tech with 'request platform software sdwan admin-tech timeout <>

ADMINTECH-3-PUBLISH_FAILURE

3-Error

Admin-tech bundle [chars] could not be uploaded to Cisco SD-WAN Manager, reason: [chars] ([dec])

This error syslog is generated when admin-tech can not be published to SD-WAN Manager over over HTTP channel. This can be due to degration in the network or control connectivity loss

cedge-admintech

Retry generating admin-tech

ADMINTECH-5-PUBLISH_SUCCESS

5-Notice

Admin-tech bundle [chars] successfully uploaded to Cisco SD-WAN Manager

This notice syslog is generated when admin-tech is successfully uploaded to SD-WAN Manager after the generation is complete

cedge-admintech

No action is required

AFC_SCHED-1-AFC_HTTPCON_HEALTHCHECK_FAILURE

1-Alert

AFC Healthcheck failed with HTTP connection error: [chars].

AFC Healthcheck failed due to HTTPCON error

afc

LOG_STD_NO_ACTION

AFC_SCHED-1-AFC_HTTP_HEALTHCHECK_FAILURE

1-Alert

AFC Healthcheck failed with HTTP status code [dec].

AFC Healthcheck failed due to HTTP error

afc

LOG_STD_NO_ACTION

AFC_SCHED-1-AFC_PROVIDER_HEALTHCHECK_FAILURE

1-Alert

AFC Healthcheck failed : [chars].

AFC Healthcheck failed due to provider error

afc

LOG_STD_NO_ACTION

AFC_SCHED-3-AFC_CLOUDM_HEALTHCHECK_FAILURE

3-Error

AFC Healthcheck failed, can't communicate with cloud services because [chars].

AFC Healthcheck failed due cloudm communication failure

afc

LOG_STD_NO_ACTION

AFC_WNCD-1-AFC_CONDITIONS_NOT_MET

1-Alert

Some geolocation information is missing for AP with Radio MAC [chars] to use AFC:[chars]

Some conditions are preventing the AP from using AFC

afc

LOG_STD_NO_ACTION

AFC_WNCD-4-AFC_GEOLOCATION_HIGH_UNCERTAINTY

4-Warning

Current location uncertainty for AP [chars] is high ([dec] meters).

Geoloocation uncertainty for the AP is above 400m

afc

LOG_STD_NO_ACTION

AFC_WNCD-6-AFC_WNCD_INFO

6-Information

Info Level - [chars]

General AFC WNCD Lib info message

ewlc-spwifi

LOG_STD_ACTION

APMGR_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_GTK_UNABLE_TO_UPDATE_BROADCAST_KEYS_TO_AP

3-Error

User ID: [chars] - Unable to update broadcast keys to AP

Unable to update broadcast keys to AP

ewlc-client

LOG_STD_ACTION

APMGR_AUDIT_MESSAGE-6-FIPS_AUDIT_FCS_COP_1_DataEncryption

6-Information

AP [chars] User ID: [chars] [chars] [chars] [chars] [chars]

TLV_AP_CC_AUDIT_PAYLOAD parameters

ewlc-ap

LOG_STD_ACTION

APMGR_AWIPS_SYSLOG-6-APMGR_AWIPS_MESSAGE

6-Information

AWIPS alarm:[chars] ([dec])

AWIPS alarm detected

ewlc-awips

LOG_STD_NO_ACTION

APMGR_TRACE_MESSAGE-2-BSSID_CLEANUP_TIMEOUT

2-Critical

BSSID cleanup timeout, [chars]

BSSID cleanup could not be completed. This may result in failure to push configuration updates to Access Points. Make a note of any recent changes made to the network or the device configuration which may have triggered this and proceed to the suggested action.

ewlc-ap

Copy the error message exactly as it appears on the console or in the system log. Open a case with the Technical Assistance Center via the Internet http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information. It is suggested to collect archive traces and live process core to analyse the error.

APMGR_TRACE_MESSAGE-2-WLAN_CRIT_ERR

2-Critical

WLAN Error : [chars]

Critical issue seen with WLAN config. Make a note of any recent changes made to the network or the device configuration which may have triggered this and proceed to the suggested action.

ewlc-ap

Copy the error message exactly as it appears on the console or in the system log. Open a case with the Technical Assistance Center via the Internet http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information. It is suggested to collect archive traces and live process core to analyse the error.

APMGR_TRACE_MESSAGE-2-WLAN_CRIT_INFO

2-Critical

CRITICAL, [chars]

General Wireless LAN Controller critical message

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-2-WLC_APMGR_CRIT_MSG

2-Critical

CRITICAL, [chars]

General Wireless LAN Controller warning message

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-AP_NTP_SYNC

3-Error

AP [chars] MAC [chars], NTP sync has failed. Reason: [chars]

The Ap failed to sync with the NTP server

ewlc-ap

Verify the IP address of the NTP server and the authentication credentials.

APMGR_TRACE_MESSAGE-3-AP_RADIO_STUCK_ALARM

3-Error

Radio Stats Monitoring: [chars]

Radio stats monitoring and radio stuck alarm

ewlc-ap

No action required

APMGR_TRACE_MESSAGE-3-EWLC_APMGR_ANTENNA_SET_ERROR

3-Error

Antenna set error: [chars]

Antenna id enable/disable operation has resulted in error. please follow error message for details

ewlc-rrm

Please follow error message string and take corrective action

APMGR_TRACE_MESSAGE-3-EWLC_APMGR_AP_REG_DOMAIN_MISMATCH

3-Error

Error: Cannot set country code [chars] for AP MAC:[chars],Regulatory domain check failed

Regulatory domain of all radio slots of the AP does not match with the country code

ewlc-rrm

In most cases, the problem can be corrected by checking regulatory domain supported by Access Point (AP). Radios within APs are assigned to a specific regulatory domain as a part of factory setting. Configuring a country code ensures that each radio's broadcast frequency bands, channels and transmit power levels are compliant with country-specific regulations. Please ensure that user configured country code is compliant with country code setting in AP.

APMGR_TRACE_MESSAGE-3-EWLC_APMGR_UNSUPPORTED_COUNTRY

3-Error

Regulatory domain error while setting country code for AP MAC:[chars], country code [chars] is not configured on WLC

Specified country code is not present in the configured country code list

ewlc-rrm

Validate the country code configuration on the Controller and add the country code to the configured country code list if it is not already present. Please refer to the configuration guide to configure country code. If you still require contact your Cisco technical support representative and provide the information you have gathered.

APMGR_TRACE_MESSAGE-3-EWLC_GEN_CHAN_ERR

3-Error

Error in [chars]

General Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-EWLC_RRM_ERROR

3-Error

event change: [chars]

General Wireless LAN Controller RRM error message

ewlc-rrm

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-EWLC_RRM_QUERY_ERR

3-Error

Error in [chars]

Trying to query information related to AP with invalid slot ID.

ewlc-rrm

Please report the error to technical support representative.

APMGR_TRACE_MESSAGE-3-EWLC_WLAN_ETA_MSG

3-Error

et-analytics config validation Error: [chars]

Global and Wireless et-analytics config dependency error

ewlc-ap

No action required

APMGR_TRACE_MESSAGE-3-EWLC_WLAN_MPSK_MSG

3-Error

MPSK config validation Error: [chars]

MPSK and Central auth dependency error

ewlc-ap

No action required

APMGR_TRACE_MESSAGE-3-EWLC_WLAN_MPSK_PSK_MSG

3-Error

MPSK config validation Error: [chars]

MPSK and PSK dependency error

ewlc-ap

No action required

APMGR_TRACE_MESSAGE-3-EXEC_CLI_INVALID_SLOT

3-Error

Executed exec-cli is not applicable for AP: [chars], number of slots: [dec], while cli executed for slot: [dec].

The executed EXEC CLI is not applicable for this AP, because the limitation number of slots

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-EXEC_CLI_NOT_5G_DUAL_RADIO_AP

3-Error

Executed exec-cli is not applicable for AP: [chars] because AP does not support dual 5ghz radio.

The executed EXEC CLI is not applicable for this AP, because AP does not support dual 5ghz radio

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-EXEC_CLI_NOT_MASTER_RADIO

3-Error

Executed exec-cli is applicable for only master radio for AP : [chars]

The executed EXEC CLI is applicable only for master radio

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-EXEC_CLI_TX_POWER

3-Error

Tx Power Config Notification: Radio Role is AUTO. So, Tx power change is not allowed for AP [chars] on slot [dec].

Tx Power configuration is not allowed.

ewlc-rrm

LOG_STD_NO_ACTION

APMGR_TRACE_MESSAGE-3-WLC_AP_AUDIT_REPORT_ERR

3-Error

Error in [chars]

AP Audit Report Error Message.

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-WLC_AP_CONFIG_CHECKER_ERR

3-Error

error received from AP [chars]

Error on AP while applying configuration updates from controller.

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-WLC_AP_JOIN_24G_DCA_CHANNEL_LIST_EMPTY

3-Error

The DCA Channel list is empty for 24ghz rf profile [chars]

DCA Channel list for 24ghz radio is empty, it affects Channel Assignment to AP

ewlc-rrm

Please add channels to DCA List

APMGR_TRACE_MESSAGE-3-WLC_AP_JOIN_5G_DCA_CHANNEL_LIST_EMPTY

3-Error

The DCA Channel list is empty for 5ghz rf profile [chars]

DCA Channel list for 5ghz radio is empty, it affects Channel Assignment to AP

ewlc-rrm

Please add channels to DCA List

APMGR_TRACE_MESSAGE-3-WLC_AP_JOIN_6G_DCA_CHANNEL_LIST_EMPTY

3-Error

The DCA Channel list is empty for 6ghz rf profile [chars]

DCA Channel list for 6ghz radio is empty, it affects Channel Assignment to AP

ewlc-rrm

Please add channels to DCA List

APMGR_TRACE_MESSAGE-3-WLC_AP_JOIN_CRIT_ERR

3-Error

AP Join/Disjoin Error: [chars]

AP Join/Disjoin Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-WLC_AP_LOG_MSG

3-Error

AP Remote Log: [chars]

AP Remote logging

ewlc-ap

No action required

APMGR_TRACE_MESSAGE-3-WLC_AP_PACKET_CAPTURE_ERR

3-Error

Error in [chars]

AP packet capture Error Message.

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-WLC_EXEC_MSG

3-Error

%% Error: [chars]

Improper arguments or config

ewlc-ap

Arguments to be changed

APMGR_TRACE_MESSAGE-3-WLC_GEN_ERR

3-Error

Error in [chars]

General Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-WLC_MDNS_AP_ERROR_MSG

3-Error

Error mDNS AP : [chars]

Error Message related to mDNS AP

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-3-WLC_UNSUPPORTED_AP_MODE_ERR

3-Error

Unsupported AP mode. [chars]

vWLC ultra-low WLCs do not support Local Mode APs. This error will be logged whenever an AP tries to join in Local Mode on a vWLC ultra-low WLC.

ewlc-ap

Fix the configuration to allow AP to join in Flexconnect Mode.

APMGR_TRACE_MESSAGE-4-AP_CPU_ALARM

4-Warning

AP [chars], MAC [chars], CPU=[dec]%%, alarm state: [dec]

An alarm was triggered for AP CPU measurements

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-4-AP_GNSS_USB_DISCONNECTED

4-Warning

AP [chars], GNSS USB Module has been removed. This might impact location availabilty and derivation for nearby APs

GNSS USB module disconnected from AP

ewlc-afc-rrm

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-4-AP_MEM_ALARM

4-Warning

AP [chars], MAC [chars], Memory=[dec]%%, alarm state: [dec]

An alarm was triggered for AP Memory measurements

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-4-AP_MERAKI_CONVERSION_FAILURE

4-Warning

AP [chars], MAC [chars], Meraki serial number: [chars], Meraki persona change result: Failed. Reason: [chars]

Conversion to Meraki AP validation result

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-4-EASYPSK_UNSUPPORTED_AP_MODE

4-Warning

Unsupported AP mode for Easy-PSK WLAN [dec] on AP [chars], MAC [chars]. Easy-PSK only supported in local mode.

Easy-PSK WLAN configured on AP not in local mode. WLAN will not be pushed to the AP.

ewlc-spwifi

Fix the configuration to move AP in local mode.

APMGR_TRACE_MESSAGE-4-WLC_APMGR_WARNING_MSG

4-Warning

Warning, [chars]

General Wireless LAN Controller warning message

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-4-WLC_CONFIG_CHECKER_WARNING

4-Warning

config check: [chars]

Warning message related to config checker

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-4-WLC_MDNS_AP_WARNING_MSG

4-Warning

Warning mDNS AP : [chars]

Warning message related to mDNS AP

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-5-AP_AFC_BELOW_TX_MIN

5-Notice

AP [chars], 6GHZ radio operating below tx min due to afc restriction

6GHZ radio operating below rf profile configured tx min due to afc restriction

ewlc-afc-rrm

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-5-AP_AFC_IMMINENT_FLAG_SET

5-Notice

AP [chars], 6GHZ radio AFC response is about to expire on AP

6GHZ AFC expiry imminent flag set

ewlc-afc-rrm

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-5-AP_COUNTRY_CODE

5-Notice

AP Name [chars] Mac: [chars] Model [chars] Type [chars] : [chars]

Resolved country code

ewlc-ap

LOG_STD_NO_ACTION

APMGR_TRACE_MESSAGE-5-AP_EXEC_CLI

5-Notice

Exec CLI : [chars]

Exec cli information or output

ewlc-ap

LOG_STD_NO_ACTION

APMGR_TRACE_MESSAGE-5-EWLC_APMGR_NOTICE

5-Notice

event change: [chars]

General Wireless LAN Controller Notice message

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-5-WLC_AP_PUBLIC_CLOUD_ERR

5-Notice

Unsupported AP mode. [chars]

Public cloud WLCs do not support Local Mode in AP. This error will be logged whenever an AP tries to join in Local Mode in a Public Cloud WLC.

ewlc-ap

Fix the configuration to allow AP to join in Flexconnect Mode.

APMGR_TRACE_MESSAGE-6-AP_MERAKI_CONVERSION_SUCCESS

6-Information

AP [chars], MAC [chars], Meraki serial number: [chars], Meraki persona change result: [chars]

Conversion to Meraki AP validation result

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-6-CHAN_ZERO_DETECTED

6-Information

AP: [chars] reported channel 0 on slot [dec]

AP has reported Channel 0 on one of the radio slots. This generally happens when the configurations on the AP are set to factory default. WLC recovers this by rebooting the AP. Unless the message repeatedly appears, it does not require any action.

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-6-CLIENT_DEBUG_BUNDLE_INFO

6-Information

Client debug bundle [chars]

General Wireless LAN Controller Client debug bundle info message

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-6-EWC_APMGR_OLD_VERSION

6-Information

AP Event: [chars] Please upgrade AP to 8.10 or 16.12 or higher before joining a EWC network

Please upgrade 11AX AP to 8.10 or 16.12 so it can join EWC network

ewcap-image

LOG_STD_NO_ACTION

APMGR_TRACE_MESSAGE-6-EWC_APMGR_POLL_CCO_SUCCESS

6-Information

CCO polling for software version completed successfully

The action of polling CCO for LATEST and SUGGESTED software version has completed successfully

ewcap-image

LOG_STD_NO_ACTION

APMGR_TRACE_MESSAGE-6-WLC_APMGR_INFO

6-Information

Info : - [chars]

General Wireless LAN Controller info message

ewlc-ap

LOG_STD_ACTION

APMGR_TRACE_MESSAGE-6-WLC_AP_JOIN

6-Information

AP Join Info : [chars]

AP Join/Disjoin Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

AP_POWER_PROFILE_TRACE_MESSAGE-3-WLC_GEN_ERR

3-Error

Error in [chars]

General Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

AUTO_FPD-3-FRU_HWPRG_UPG_ERR

3-Error

Error reason:[chars]

Some error occurred during auto upgrade

iosxe-binos-utils

Retry upgrade

AUTO_FPD-3-FRU_HWPRG_UPG_FAILED

3-Error

[chars] in slot [chars] failed to program. error: [chars]

The hw-programmable was upgraded failed

iosxe-binos-utils

Retry upgrade

AUTO_FPD-5-FRU_HWPRG_UPG_START

5-Notice

[chars] in slot [chars] are upgrading, please don't reload or power-cycle this card.

The hw-programmable firmware is upgrading

iosxe-binos-utils

No action is required. This is informational message

AUTO_FPD-5-FRU_HWPRG_UPG_SUCCESS

5-Notice

[chars] in slot [chars] are successfully programmed.

The hw-programmable was upgraded succesfully

iosxe-binos-utils

No action is required. This is informational message

AUTO_UPGRADE-3-AUTO_ADVISE_SW_COM_BUNDLED

3-Error

Switch [dec] running incompatible bundled software has been added to the stack. Switch [dec] must be running compatible bundled software in order to join the stack.

No explanation required.

iosxe-binos-utils

Boot the member with compatible software.

AUTO_UPGRADE-3-AUTO_ADVISE_SW_FAILED_PLATFORM

3-Error

Failed to determine platform hardware type of switch [dec]

Somehow the platform type could not determined.

iosxe-binos-utils

Add an action

AUTO_UPGRADE-3-AUTO_ADVISE_SW_MODE_UNKNOWN

3-Error

Switch [dec] has been added to the stack. Failed to initiate auto advise for switch [dec] because switch [dec] is not running installed or bundled software

No explanation required.

iosxe-binos-utils

Boot the member with compatible software.

AUTO_UPGRADE-3-AUTO_CONF_EXEC

3-Error

Auto upgrade is enabled by config. Please disable auto upgrade configuration to execute auto upgrade manually using exec CLI.

TODO: add an explanation.

iosxe-binos-utils

TODO: add an action

AUTO_UPGRADE-3-AUTO_UPGRADE_FAILED_COPY

3-Error

Failed to copy upgrade packages from [chars] [dec] to [chars] [dec]/R[dec].

TODO: add an explanation.

iosxe-binos-utils

TODO: add an action

AUTO_UPGRADE-3-AUTO_UPGRADE_FAILED_DISK

3-Error

[chars] [dec]/[dec] doesn't have enough free disk space to perform auto upgrade. A minimum of [dec] KB of free disk space is required Initiating the auto-delete of the old images on joining member/FRU. (Default is oldest image in configuration mode)

There might be older files because of which there is not enough memory.

iosxe-binos-utils

Clean up disk space in the remote switch.

AUTO_UPGRADE-3-AUTO_UPGRADE_FAILED_EXPAND

3-Error

Failed to install the running software on switch [dec]

TODO: add an explanation.

iosxe-binos-utils

No action required.

AUTO_UPGRADE-3-AUTO_UPGRADE_FAILED_MEM

3-Error

[chars] [dec] doesn't have enough free memory to perform auto upgrade. A minimum of [dec] KB of free memory is required

There might be older files because of which there is not enough memory.

iosxe-binos-utils

Clean up disk space in the remote switch.

AUTO_UPGRADE-3-AUTO_UPGRADE_FAILED_PLATFORM

3-Error

Failed to determine platform hardware type of [chars] [dec]/R[dec]

Somehow the platform type could not determined.

iosxe-binos-utils

Add an action

AUTO_UPGRADE-3-AUTO_UPGRADE_FAILED_STATE

3-Error

A previous provisioning action is pending reboot. Please reboot the [chars] [dec].

The user has run an operation that requires a reboot to take action.

iosxe-binos-utils

Reload the switch

AUTO_UPGRADE-3-AUTO_UPGRADE_INTERNAL_ERROR

3-Error

Local chassis/RP number did not publish yet

Somehow the chassis/FRU number is missing.

iosxe-binos-utils

Try to do it again.

AUTO_UPGRADE-3-AUTO_UPGRADE_MODE_UNKNOWN

3-Error

Switch [dec] has been added to the stack. Failed to initiate auto upgrade for switch [dec] because switch [dec] is not running installed or bundled software

No explanation required.

iosxe-binos-utils

Boot the member with compatible software.

AUTO_UPGRADE-3-AUTO_UPGRADE_NOTHING_TO_CLEAN

3-Error

Couldn't find enough old install images on incompatible standby/member for deletion. Please manually free up [dec] MB space on incompatible standby/member and try again using 'install autoupgrade'.

If there is no old images are found on joining standby/member's boot directory

iosxe-binos-utils

User will have to manually delete old files using IOS delete command

AUTO_UPGRADE-3-AUTO_UPGRADE_NOTHING_TO_UPGRADE

3-Error

No incompatible standby/member is found, nothing to auto-upgrade.

Exec autoupgrade scenario when there is no incompatible member in stack.

iosxe-binos-utils

No action is required from the user

AUTO_UPGRADE-3-AUTO_UPGRADE_NOT_SUPPORTED

3-Error

The system is not running installed software. Auto upgrade for [chars] [dec]/R[dec] cannot be initiated

A system with incompatible software has been detected in the stack. The auto upgrade functionality cannot be initiated because the stack/HA system is not running installed software. The user must manually upgrade the incompatible switch/FRU.

iosxe-binos-utils

Perform the one shot cli to convert system is install mode. Boot the system from the boot directory (bootflash/harddisk) using 'boot bootflash:packages.conf'

AUTO_UPGRADE-3-AUTO_UPGRADE_NO_DOWNGRADE

3-Error

Skip auto-upgrade on chassis [dec]. The Active chassis's software version [chars] is lower than this chassis's minimum software version requirement [chars].

Skip auto-downgrade scenario when the active switch does not fulfill the minimum software release version requirment. The active switch is running an image lower than the remote chassis's minimum software version.

iosxe-binos-utils

Upgrade the stack to a higher release version or remove the switch from the stack.

AUTO_UPGRADE-3-AUTO_UPGRADE_PLATMISMATCH

3-Error

No software was found to upgrade [chars] [dec]/R[dec]

Happens because of incompatible switches. For example, ngwc and non-ngwc ones are incompatible

iosxe-binos-utils

Plugin compatible switches for autoupgrade to run.

AUTO_UPGRADE-3-AUTO_UPGRADE_ROMMON_NOT_UPDATED

3-Error

Unable to confirm boot config on [chars] [dec]/R[dec], assuming it is set as [chars].

TODO: add an explanation.

iosxe-binos-utils

NO action is required.

AUTO_UPGRADE-3-SMU_SYNC_FAILED

3-Error

SMU upgrade failed on switch [dec]. Auto upgrade of image will pass with out syncing SMUs on this switch. SMUs will be synced at boot time of the switch [dec]

SMU sync failed because of some reason.

iosxe-p-smu

No action required, SMU sync will be tried in next reload.

AUTO_UPGRADE-3-SMU_UPGRADE_FAILED_DISK

3-Error

Switch [dec] doesn't have enough free disk space to sync SMU. A minimum of [dec] KB of free disk space is required. Auto upgrade will pass with out syncing SMUs on this switch

There might be older files because of which there is not enough memory.

iosxe-p-smu

Clean up disk space in the remote switch.

AUTO_UPGRADE-5-AUTO_ADVISE_SW_BUNDLED

5-Notice

switch [dec] running installed software has been added to the stack. Switch [dec] must be running bundled software in order to join the stack.

No explanation required.

iosxe-binos-utils

Boot the member with compatible software.

AUTO_UPGRADE-5-AUTO_ADVISE_SW_CONV

5-Notice

[chars] [dec] running bundled software has been added to the stack that is running installed software. The 'install autoupgrade' command can be used to convert [chars] [dec] to the installed running mode by installing its running software.

No explanation required.

iosxe-binos-utils

No specific action required.

AUTO_UPGRADE-5-AUTO_ADVISE_SW_FOUND

5-Notice

Found donor switch [dec] to auto upgrade switch [dec].

Just an init message.

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_ADVISE_SW_INITIATED

5-Notice

Auto advise initiated for [chars] [dec].

A system with incompatible software has been detected in the stack. The stack will now determine whether or not software is available to be copied to the incompatible system, and if so, advise the user how to copy it. Otherwise, the system will merely let the user know that the software on the stack needs to be updated.

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_ADVISE_SW_MSG

5-Notice

[chars] [dec]/R[dec] with incompatible software has been added to the system/stack. all system/stack members were scanned and it has been determined that the 'install autoupgrade' command can be used to install compatible software on [chars] [dec]/R[dec].

TODO: add an explanation.

iosxe-binos-utils

TODO: add an action

AUTO_UPGRADE-5-AUTO_ADVISE_SW_SEARCH

5-Notice

Searching stack for software to upgrade [chars] [dec]/R[dec].

Just an init message.

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_ADVISE_SW_START

5-Notice

Upgrading [chars] [dec] with software from [chars] [dec].

Just an init message.

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_UPGRADE_CONV

5-Notice

Converting [chars] [dec] to installed mode by installing its running software.

This needs to be converted as part of the auto upgrade.

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_UPGRADE_FINISH

5-Notice

Finished installing software on [chars] [dec]/R[dec].

TODO: add an explanation.

iosxe-binos-utils

TODO: add an action

AUTO_UPGRADE-5-AUTO_UPGRADE_FOUND

5-Notice

Found donor [chars] [dec] to auto upgrade [chars] [dec]/R[dec].

Just an init message.

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_UPGRADE_INITIATED

5-Notice

Auto upgrade initiated for [chars] [dec]/R[dec].

A system with incompatible software has been detected in the stack. The stack will first attempt to download software from a previously-configured location, and install it to make the system compatible. If this is not successful, the stack will then determine whether running software on another stack member is available to be copied to the incompatible system, and whether or not it is appropriate to copy the software automatically

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_UPGRADE_INSTALLED

5-Notice

Finished installing the running software on [chars] [dec].

TODO: add an explanation.

iosxe-binos-utils

TODO: add an action

AUTO_UPGRADE-5-AUTO_UPGRADE_RELOAD

5-Notice

Reloading [chars] [dec] to complete the auto upgrade.

Part of autoupgrade

iosxe-binos-utils

Just wait until the reload completes.

AUTO_UPGRADE-5-AUTO_UPGRADE_RELOAD_INSTALLED

5-Notice

Reloading [chars] [dec] to boot in installed mode.

TODO: add an explanation.

iosxe-binos-utils

TODO: add an action

AUTO_UPGRADE-5-AUTO_UPGRADE_SEARCH

5-Notice

Searching stack for software to upgrade [chars] [dec]/R[dec].

Just an init message.

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_UPGRADE_START

5-Notice

Upgrading [chars] [dec]/R[dec] with software from [chars] [dec].

Just an init message.

iosxe-binos-utils

No action is required.

AUTO_UPGRADE-5-AUTO_UPGRADE_START_CHECK

5-Notice

Auto upgrade start checking for incompatible switches.

Part of autoupgrade

iosxe-binos-utils

NO action is required.

AUTO_UPGRADE-5-SMU_RB_SYNC_FAILED

5-Notice

SMU rollback sync failed on [chars]. Rollback operations may be affeced

SMU rollback sync failed on some reason. Most probable causes are SMUs are not present on the media or the media is full.

iosxe-p-smu

Bring back the SMUs deleted and check whether there is enough space in remote member/SMUs

AUTO_UPGRADE_MODULAR-3-AUTO_ERR_SMU_SYNC_FAILED

3-Error

Failed to sync SMUs to standby. Make sure that SMU files are present on active and there is space enough to copy SMUs on standby.

SMU sync failed. Most probable cause are the smu files may have been removed from the active switch using IOS/linux commands. Another reason is there is no space enough to copy the files to the standby

iosxe-p-smu

If the files are removed from the active bring it back to same location. Make sure there is enough space to copy the files on the standby

AUTO_UPGRADE_MODULAR-3-AUTO_NOTICE_RUN_CORRECTION_FAILED

3-Error

Failed to correct the SMU mismatch between the running version on active and standby. Pls abort the smu installation using 'install abort'

The system tried to recover from the missmatch, but failed. Engineer intervention is required

iosxe-p-smu

Get the 'show install log' and the btrace logs from active and standby

AUTO_UPGRADE_MODULAR-5-AUTO_ADVISE_SW_MISSMATCH

5-Notice

Active and standby are running differnt versions, SMUs will not be synced.

No explanation required.

iosxe-binos-utils

Boot the member with same software.

AUTO_UPGRADE_MODULAR-5-AUTO_NOTICE_RUN_MISSMATCH_STBY_RELOAD

5-Notice

Missmatch between running version of SMUs. Trying to recover. Standby will reload

There is a missmatch on the running version. This will happen when the standby reloads after activate/deactivate and before commit. The machine will try to correct it. One reload is required for correcting the chanages.

iosxe-binos-utils

No action required.

AUTO_UPGRADE_MODULAR-5-AUTO_NOTICE_STBY_RELOAD

5-Notice

Installing SMUs on standby. Standby will reload

No explanation required.

iosxe-binos-utils

No action required.

AUTO_UPGRADE_MODULAR-5-SMU_AUTO_UPGRADE_INITIATING

5-Notice

Initiating SMU autoupgrade for [chars] [dec]/R[dec]

No explanation required.

iosxe-binos-utils

Boot the member with same software.

AVC_MESSAGE-3-EWLC_AVC_FNF_CLI_ERR

3-Error

CLI validation error: [chars]

General AVC FNF CLI validation error

iosxe-binos-utils

LOG_STD_ACTION

BBU-0-CHASFS_OBJECT_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] not present.

A chassis filesystem object expected to be present is not. This could be due to a software defect or filesystem failure.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-0-CHASFS_PROPERTY_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly created.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-0-CHASFS_PROPERTY_GET

0-Emergency

Failed to read chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly read by the system.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-0-CHASFS_PROPERTY_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] property [chars] not present.

A chassis filesystem object property expected to be present is not. This could be due to a software defect or filesystem failure.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-0-CHASFS_PROPERTY_SET

0-Emergency

Failed to write chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property failed to write.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-0-SERVICES_INITIALIZATION

0-Emergency

Failed to initialize general application services because [chars]

The system failed to initialize application services.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-0-UIPEER_CREATE

0-Emergency

Failed to create user interface peer.

The system failed to create a user interface peer.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-3-BAD_CELL

3-Error

Bad battery cell detected in unit [dec]

Battery firmware detected a bad cell, which can't be recharged.

cabo-platform

Replace the bad battery unit.

BBU-3-CHASFS_PROPERTY_DESTROY

3-Error

Failed to destroy chassis filesystem property [chars]/[chars] because [chars]

A chassis filesystem property that should have been destroyed was not destroyed.

cabo-platform

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-3-CLI_ERROR

3-Error

[chars] command execution failed with err=[dec]

CLI execution failed

cabo-platform

No user action is required.

BBU-3-COMM_ERR

3-Error

Battery communication error: [chars]

Battery communication error.

cabo-platform

Collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-3-FW_UPGRADE_FAILED

3-Error

Firmware upgrade failed with error [dec]

Battery firmware upgrade failed.

cabo-platform

Check battery status.

BBU-3-HW_INIT_PH_ERR

3-Error

Hardware init phase error, [chars] init returned [dec]

Hardware failed to initialize.

cabo-platform

Collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-3-HW_RUNTIME_ERR

3-Error

Hardware runtime error, [chars] init returned [dec]

Hardware failed.

cabo-platform

Collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BBU-4-AC_TO_DC_TRANSITION

4-Warning

AC power is off, running on batteries.

Lost power from AC power line, system is powered by backup batteries.

cabo-platform

Check AC power line.

BBU-4-FW_UPGRADE_STARTED

4-Warning

Firmware upgrade to version [dec] started

Battery firmware upgrade started.

cabo-platform

No user action is required.

BBU-4-LOW_LEVEL

4-Warning

Battery charge running low ([dec]%%)

Battery charge is below low level threshold.

cabo-platform

Check AC power line.

BBU-4-STATUS_CHANGE

4-Warning

The [chars] parameter for BBU unit [dec] has changed

Status change of BBU parameters

cabo-platform

No user action is required.

BBU-5-BBU_EVT_LOG

5-Notice

Battery Event Log - [chars]:[chars] \n

BBU Event Log Data.

cabo-platform

No user action is required.

BBU-5-CELL_RECOVERED

5-Notice

Battery cell in unit [dec] recovered

A battery cell, which was previously detected to be bad, has now recovered.

cabo-platform

No user action is required.

BBU-5-CLI_OK

5-Notice

Command [chars]

CLI execution successful.

cabo-platform

No user action is required.

BBU-5-DC_TO_AC_TRANSITION

5-Notice

AC power is back on, running on power line

AC power is restored, system is powered by AC power line

cabo-platform

No user action is required.

BBU-5-FW_UPGRADE_FINISHED

5-Notice

Firmware upgrade finished successfully

Battery firmware upgrade finished.

cabo-platform

No user action is required.

BBU-5-HW_HOTPLUG

5-Notice

Battery detected, started initialization

Battery hotplugged in the system, Started probing and initialization.

cabo-platform

No user action is required.

BBU-5-NORMAL_LEVEL

5-Notice

Battery charge reached normal level ([dec]%%)

Battery charge is above low level threshold.

cabo-platform

No user action is required.

BBU-7-FSM_TRANSITION

7-Debug

FSM transition ([dec], [dec]) -> [dec]

FSM transition (old_state, event) -> new state

cabo-platform

No user action is required.

BCRDU-3-PATCH_ACTIVATE_FAIL_MESSAGE

3-Error

Failed to activate patch. The patch name is [chars] and the reason is: [chars]

During system reload, all committed patches will be automatically activated.For some reason, a patch activation fails.

iosxe-binos-utils

Check [bcrdu] ERR entries in the log files for message reporting problems.

BCRPGC-3-REFERENCE_STUBBED

3-Error

Stubbed [chars] is referenced

Stubbed function/variable is referenced.

iosxe-binos-utils

File a DDTS and attach the backtrace

BCRPGC-3-USWAP_ERROR

3-Error

uswap error - no space on [chars]

Path for USWAP files.

iosxe-binos-utils

If this error is seen, it is recommended to clean up the flash usage. If more assistance is required, file a DDTS, attach the backtrace and btrace

BFDMGR-5-BFD_STATE_CHANGE

5-Notice

BFD tunnel ([chars]:[dec] => [chars]:[dec], [chars]) state changed to [chars], Local-TLOC: [chars]/[chars], Remote-TLOC: [chars]/[chars], reason for state change: [chars]

This syslog is generated when a BFD tunnel state changes

cedge-forwarding

No action is required

BFDMGR-6-BFD_SLA_CHANGE

6-Information

BFD tunnel ([chars]:[dec] => [chars]:[dec], [chars]) SLA changed from [chars] to [chars], Local-TLOC: [chars]/[chars], Remote-TLOC: [chars]/[chars] PFR stats: [chars]

This syslog is generated whenever SLA of a BFD tunnel running on top of specific TLOC changes

cedge-forwarding

No action is required

BINOS_LOGIN-3-AUTHERR

3-Error

The authentication process failed, [chars]

This error occurs when there is an error in the system that prevents the user from being successfully authenticated

iosxe-binos-utils

LOG_STD_NO_ACTION

BINOS_LOGIN-3-NOTROOT

3-Error

login attempted to run without proper credentials.

login can not be run without proper credentials.

iosxe-binos-utils

LOG_STD_NO_ACTION

BINOS_LOGIN-3-NOTTY

3-Error

login attempted but stdin is not a tty

login can not be run without stdin set to tty

iosxe-binos-utils

LOG_STD_NO_ACTION

BINOS_LOGIN-3-PAMERR

3-Error

PAM error [chars] encountered.

The system encountered a PAM error.

iosxe-binos-utils

LOG_STD_NO_ACTION

BINOS_LOGIN-3-PWNOENT

3-Error

No entry for user [chars] in passwd file

The username/password authenticated correctly, but the user's environment could not be established because the user's environment data is missing.

iosxe-binos-utils

LOG_STD_NO_ACTION

BINOS_LOGIN-6-PAMAUTHDENY

6-Information

User was not authenticated

User was not authenticated

iosxe-binos-utils

LOG_STD_NO_ACTION

BINOS_LOGIN-6-PAMMAXTRIES

6-Information

Maximum number of retries exceeded.

The user tried and failed too many times to login.

iosxe-binos-utils

LOG_STD_NO_ACTION

BIPC-3-BIPC_PERFORMANCE

3-Error

buffer size request [dec] failed

An internal buffer allocation has failed.

iosxe-binos-utils

No action is required. If the problem persists, or router performance is noticeably degraded, contact Cisco technical support. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

BIPCMGR-3-INVALID_TDL_ERROR_ON_MARSHAL

3-Error

TDL epoch error on marshal [dec] unexpected: [chars]

The bipc manager has attempt to marshal a message to be sent. The tdl library has generated an error on marshal that is unexpected. The message was not sent.

iosxe-binos-utils

This is unexpected. Report this to Cisco TAC

BOOT-0-APP_STARTFAILCRIT

0-Emergency

Failed to launch a critical process [chars]

A process important to the chassis has failed.

iosxe-binos-utils

Note the time of the message and investigate the error message logs to learn more about the problem. If the problem persists or cannot be resolved, copy the error message and the output of show platform software tech-support into a plaintext file and contact Cisco technical support.

BOOT-0-BOOT_BADDIMM

0-Emergency

WARNING: This memory configuration: [chars] is not supported on this platform!

This memory configuration isn't supported on this platform.

iosxe-binos-utils

Change memory configuration to a supported one.

BOOT-0-BOOT_COMPLETE_FAIL

0-Emergency

Critical boot tasks failed: [chars]

The system has encountered a critical failure preventing successful boot.

iosxe-binos-utils

Note the time of the error message and system logs for additional information on the problem. If you are unable to resolve this problem, copy the error message and the output of show platform software tech-support into a plaintext file and contact Cisco technical support.

BOOT-0-BOOT_NOSPACE

0-Emergency

WARNING: No space on bootflash [chars] for packages, using system memory! Delete files from bootflash to free memory and reload the system; otherwise, system behavior will be unpredictable due to high memory utilization.

Failed to boot system from bootflash. Image is booting from system memory! Delete files from bootflash to free memory and reload the system; otherwise, system behavior will be unpredictable due to high memory utilization.

iosxe-binos-utils

Delete files from bootflash to free memory and reload the system.

BOOT-0-BOOT_VERITY_CORRUPT

0-Emergency

Verity device [chars] is corrupted. Reloading FRU.

The integrity check of the verity mapped device has failed.

iosxe-binos-utils

Check image integrity.

BOOT-0-DRV_INITFAIL

0-Emergency

[chars] driver failed to initialize properly

A kernel driver that is critical to the functioning of the system failed to initialialize properly.

iosxe-binos-utils

Note the time of the error message and check the kernel error logs for additional information on the problem. If you are unable to resolve this problem, copy the error message and the output of show platform software tech-support into a plaintext file and contact Cisco technical support.

BOOT-0-DRV_LOADFAIL

0-Emergency

Failed to load driver [chars] ( [chars] )

A kernel driver that was critical to the functioning of the system failed to load.

iosxe-binos-utils

Note the time of the error message and check the kernel error logs for additional information on the problem. If you are unable to resolve this problem, copy the error message and the output of show platform software tech-support into a plaintext file and contact Cisco technical support.

BOOT-3-APP_STARTFAIL

3-Error

Failed to launch process [chars]

A process that does not affect the forwarding of network traffic failed to start.

iosxe-binos-utils

If the failed process is not something that needs to be corrected, do not address this message. If the failed process needs to be addressed, install new software and reload the router.

BOOT-3-BOOTTIME_GET_ISSU_INFO_OF_REMOTE_CHASSIS_FAILED

3-Error

Failed to get ISSU information from remote chassis. Details: [chars]

Failed to get remote switch information for compatibility check. This could be for multiple underlying failures such as reachability of peer member lost or remote member not responding

iosxe-binos-utils

If standby is stuck retry with reloading standby. If standby does not comes up even after reloading attempts, try reloading the whole stack to recover.

BOOT-3-BOOTTIME_INCOMPATIBLE_SW_DETECTED

3-Error

Incompatible software detected. Details: [chars]

Incompatible software is detected on target fru/chassis.

iosxe-binos-utils

Upgrade manually or check auto-upgrade configuration.

BOOT-3-BOOTTIME_MISMATCH_RESTRICTED_STACK_SETUP_DETECTED

3-Error

Mismatch detected. Details: [chars]

Incompatible stacked setup detected on target fru/chassis.

iosxe-binos-utils

Switch with mismatch require to be reloaded

BOOT-3-BOOTTIME_SMU_MISSING_DETECTED

3-Error

SMU file [chars] missing and system impact will be unknown

SMU file not found during bootup.

iosxe-p-smu

System will be running without the fix from the SMU

BOOT-3-BOOTTIME_SMU_RUN_CORRECTION_FAILED

3-Error

Failed to correct the SMU mismatch between the running version on active and [chars]. Pls abort the smu installation using 'install abort'

The system tried to recover from the missmatch, but failed. Engineer intervention is required

iosxe-p-smu

Get the 'show install log' and the btrace logs from active and standby

BOOT-3-BOOTTIME_SMU_SYNC_FAILED

3-Error

Failed to copy the SMUs to switch [chars]. Reload cancelled and switch will be declared incompatible

SMU sync failed on newly joined switch.

iosxe-p-smu

Switch with mismatch will be declared incompatible. Check the space on the remote switch. Check whether the file is present on active.

BOOT-3-COMP_SW_TREE_DIR_CREATION

3-Error

COMP_SW_TREE directory is being generated

If chasfs/issu directory is missing on active, this message is displayed and the directory and its contents are being regenerated

iosxe-binos-utils

No user action is necessary. This is an informative message.

BOOT-3-DUAL_BOOT_MEMORY

3-Error

Dual IOS boot indicated in ROMMON ([chars]), unavailable on [chars] RP

Running two IOS instances on the same RP is unavailable on route-processors with insufficient memory

iosxe-binos-utils

Unset the specified ROMMON variable or increase the memory on the route-processor.

BOOT-3-EXT_ISSU_CHK_FAILED

3-Error

Detected booting up of standby RP with image beyond the ISSU domain of active RP by the [chars] process. The standby RP is forced to reset.

If standby RP is booted up with an image which is beyond the ISSU software domain of the active RP's image, the functionality of active RP may be unpredictable. Hence the standbby is being reset.

iosxe-binos-utils

Remove the standby RP FRU from the chassis or boot it up with an image whose version is compatible with current running active RP.

BOOT-3-FLASH_READ_FAIL

3-Error

failed to get [chars] from flash

Property not populated.

iosxe-binos-utils

No user action is necessary. This is informative message.

BOOT-3-FSCK_FAILED

3-Error

filesystem on [chars] contains errors fsck couldn't resolve.

A device's file system consistency check failed & fsck utility was unable to repair it.

iosxe-binos-utils

If this occurs frequently, contact Cisco technical support representative.

BOOT-3-OPMODE_ERR

3-Error

Device-mode error : [chars]

The system has encountered a device-mode failure during boot.

iosxe-binos-utils

The device-mode booting err information captured with console logging For information, try show platform softwate device-mode CLI.

BOOT-3-PARTIAL_CORE_CLEANUP_FAILURE

3-Error

Partial core clean up failed for [chars]: [chars]

During RP boot, a failure occurred cleaning up incomplete core files.

iosxe-binos-utils

Please check the router file systems.

BOOT-3-SYSD_STARTFAIL

3-Error

Failed to launch boot task [chars] ( [chars] )

A boot task failed to start.

iosxe-binos-utils

If the failed boot task is not something that needs to be corrected, do not address this message. If the failed boot task needs to be addressed, install new software and reload the router.

BOOT-4-BOOT_CORRUPT

4-Warning

Boot Partition corrupted.

Boot Parition on the router is corrupted. Router booting from bootflash.

iosxe-binos-utils

Contact Cisco technical support.

BOOT-5-BOOTTIME_RB_SYNC_FAILED

5-Notice

Failed to sync the SMUs to switch [chars]. Install rollback operation may get affected.

Rollback point sync failed on newly joined switch.

iosxe-p-smu

Switch will not have the rollback points. Check the space on the remote switch.

BOOT-5-BOOTTIME_SMU_MISMATCH_DETECTED

5-Notice

SMU mismatch from active detected. SMUs will be copied and switch [chars] will be reloaded

SMU mismatch found on newly joined switch.

iosxe-p-smu

Switch with mismatch will be reloaded

BOOT-5-BOOTTIME_SMU_RUN_MISMATCH_DETECTED

5-Notice

Running SMU mismatch from active dectected. System will try to correct it, switch [chars] will be reloaded

Running version of SMU mismatch found on newly joined switch.

iosxe-p-smu

Stack will try to correct itself.

BOOT-5-BOOTTIME_SMU_TEMP_ACTIVE_DETECTED

5-Notice

SMU file [chars] active temporary... SMU commit is pending

SMU file is active temporary and 'install commit' needs to be run to make it permanent. Else reload without commit will deactive this SMU.

iosxe-p-smu

Execute 'install commit' before reload to make activate permanent.

BOOT-5-BOOTTIME_SMU_TEMP_DEACTIVE_DETECTED

5-Notice

SMU file [chars] deactive temporary... SMU commit is pending

SMU file is deactive temporary and 'install commit' needs to be run to make it permanent. Else reload without commit will active this SMU again.

iosxe-p-smu

Execute 'install commit' before reload to make deactivate permanent.

BOOT-5-OPMODE_LOG

5-Notice

Device-mode logging : [chars]

The device-mode booting information.:

iosxe-binos-utils

The device-mode booting information captured with console logging For information, try show platform softwate device-mode CLI.

BOOT-6-APP_START

6-Information

The process [chars] has started

The process has successful launched and begun executing.

iosxe-binos-utils

No user action is necessary. This message indicates the system is functioning normally and is provided for informational purposes only.

BOOT-6-DRV_LOAD

6-Information

Loaded driver [chars]

A kernel driver that was critical to the functioning of the system was successfully loaded.

iosxe-binos-utils

No user action is necessary. This message indicates the system is functioning normally and is provided for informational purposes only.

BOOT-6-PARTIAL_CORE_REMOVED

6-Information

Removed incomplete core file: [chars]

On boot of the RP, an incomplete core file was found and removed. Incomplete core files can happen for a variety or reasons, including the coincident failure of the active RP while a core file is being generated.

iosxe-binos-utils

No action required. This is not an error, it is an indication that the system is cleaning up a previous error.

BRELAY-3-LOCATE_FRU

3-Error

Command could not be executed. Target FRU could not be resolved

The brelay process is responsible for determining the target of a command, either local or a remote brelay instance. Control is returned to IOSd by exiting the brelay instance.

iosxe-binos-utils

Check the status of the command target. Check the brelay log files for further indications as to why the initialization failed and if necessary restart the machine.

BSHELL-3-EXEC_DIRECTIVE_FAIL

3-Error

[[chars]] Command directive execution failed: [chars]

The diagnostic shell was unable to execute the requested directive.

iosxe-binos-utils

Check the diagnostic shell trace file for more information on the underlying failure.

BSHELL-3-EXEC_FAIL

3-Error

[[chars]] Command execution failed

The diagnostic shell was unable to execute the requested interactive command.

iosxe-binos-utils

Check the diagnostic shell trace file for more information on the underlying failure.

BSHELL-3-EXEC_PREPARE_FAIL

3-Error

[[chars]] Command execution prepare failed

The diagnostic shell was unable to prepare the requested interactive command for execution. The command failed.

iosxe-binos-utils

Check the diagnostic shell trace file for more information on the underlying failure.

BSHELL-3-GET_HOSTNAME_FAIL

3-Error

[[chars]] Get hostname failed: [chars]

The diagnostic shell was unable to read the hostname from the kernel.

iosxe-binos-utils

No action is required. The diagnostic shell periodically checks for hostname changes to set the user prompt.

BSHELL-3-RECEIVE_MESSAGE_FAILED

3-Error

[[chars]] Receive message [chars] failed: [chars]

The diagnostic shell was unable to receive a message from the Shell Manager

iosxe-binos-utils

Retry the operation or start a new diagnostic shell session.

BSHELL-3-SEND_MESSAGE_FAILED

3-Error

[[chars]] Send message [chars] failed: [chars]

The diagnostic shell was unable to send a message to the Shell Manager.

iosxe-binos-utils

Retry the operation or start a new diagnostic shell session.

BSHELL-3-TERMINAL_OPERATION_FAIL

3-Error

[[chars]] Terminal [chars] [chars] failed: [chars]

The diagnostic shell was unable to get or set terminal properties. An attempt to change or act on terminal properties failed.

iosxe-binos-utils

Restart the diagnostic shell and reattempt the failed operation

BSHELL-6-BSHELL_UPGRADE_DETECTED

6-Information

[[chars]] New software detected. Bshell instance restarting.

The diagnostic shell detected a new installation of diagnostic shell software. The diagnostic shell instance exits and restarts with the new software version.

iosxe-binos-utils

This is an informational message only. No action is required.

BSHELL-6-SESSION_ENDED

6-Information

[[chars]] bshell session ended for user '[chars]'

A user has exited a diagnostic shell session.

iosxe-binos-utils

This is an informational message only. No action is required.

BSHELL-6-SESSION_STARTED

6-Information

[[chars]] bshell session started for user '[chars]'

A user has started a diagnostic shell session.

iosxe-binos-utils

This is an informational message only. No action is required.

BSHELL-6-SMAN_CONNECTION_FAILED

6-Information

[[chars]] Shell Manager connect failed: [chars]

The diagnostic shell is unable to connect to the Shell Manager, possibly because the Shell Manager process is no longer available. This type of error is experienced if a software upgrade is in progress.

iosxe-binos-utils

No action is required. Once the Shell Manager process has restarted, the diagnostic shell will reconnect.

BSHELL-6-SMAN_CONNECTION_LOST

6-Information

[[chars]] Shell Manager connection lost

The diagnostic shell was disconnected from the Shell Manager and the Shell Manager process is no longer available. This type of error is experienced if a software upgrade is in progress.

iosxe-binos-utils

This is an informational message only. No action is required. Once the Shell Manager process has restarted, the diagnostic shell will reconnect.

BSMRP-0-CHASFS_LOCATION_TRANSLATE

0-Emergency

Failed to translate a location to a chasfs object name because [chars]

The backplane switch manager failed to translate a location to a chasfs object name.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASFS_OBJECT_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] because [chars]

The hardware failed to create a chassis filesystem object.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASFS_OBJECT_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] not present.

A chassis filesystem object expected to be present is not. This could be due to a software defect or filesystem failure.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASFS_OBJECT_WATCH

0-Emergency

Failed to watch chassis filesystem object [chars] because [chars]

A chassis filesystem object was not watched because of the reason stated in the error message.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASFS_PROPERTY_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly created.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASFS_PROPERTY_GET

0-Emergency

Failed to read chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly read by the system.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASFS_PROPERTY_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] property [chars] not present.

A chassis filesystem object property expected to be present is not. This could be due to a software defect or filesystem failure.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASFS_PROPERTY_SET

0-Emergency

Failed to write chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property failed to write.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASSIS_STATUS

0-Emergency

Failed to get chassis hardware status because [chars]

The system failed to get the chassis hardware status.

esg-bsm

Note the time of the error message and examine the logs for CPLD driver or hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-CHASSIS_TYPE

0-Emergency

The chassis type [chars] is invalid.

The chassis type is invalid. This could be due to a hardware defect, software defect or incorrect IDPROM content.

esg-bsm

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-INVALID_ARGUMENT

0-Emergency

A system function was given an invalid argument.

A system function was given an invalid argument. This is due to a software defect.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-IPC_CONNECTION_INVALID

0-Emergency

An IPC connection has invalid state.

An IPC connection has an invalid state. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-IPC_CONNECT_MASTER

0-Emergency

IPC connection to the active RP failed because [chars]

IPC connection to the active RP failed. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-IPC_INITIALIZATION

0-Emergency

IPC initialization failed because [chars]

IPC initialization failed. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-MESSAGE_REGISTER

0-Emergency

Failed to register with active RP because [chars]

The active RP failed to register.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-MESSAGE_RELAY

0-Emergency

Failed to relay a message because [chars]

Failed to relay a message. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-MESSAGE_RESPONSE

0-Emergency

An invalid message response was received because [chars]

An invalid message response was received. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-MQIPC_ADVANCE

0-Emergency

Failed to advance MQIPC queue because [chars]

The MQIPC initialization failed.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-MQIPC_INITIALIZATION

0-Emergency

MQIPC initialization failed because [chars]

MQIPC initialization failed. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-PEER_TABLE

0-Emergency

A peer table initialization or maintenance function failed because [chars]

A peer table initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-PLATFORM_FAMILY_TYPE

0-Emergency

The platform family type [chars] is invalid.

The platform family type is invalid. This could be due to a hardware defect, software defect or incorrect IDPROM content.

esg-bsm

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-RESOLVE_FRU

0-Emergency

Failed to determine [chars] card because [chars]

The router failed to determine a FRU state.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-SERVICES_INITIALIZATION

0-Emergency

Failed to initialize general application services because [chars]

The system failed to initialize application services.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-SIGNAL_INITIALIZATION

0-Emergency

Failed to initialize signals because [chars]

The system failed to initialize signals.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-SLOTS_INITIALIZATION

0-Emergency

Failed to initialize chassis slot information because [chars]

The system failed to initialize the chassis slot information.

esg-bsm

Note the time of the error message and examine the logs for IDPROM or software errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-SLOT_INVALID

0-Emergency

A card absolute slot number cannot be determined for this chassis type

An absolute slot number is invalid. This could be due to a software defect or incorrect IDPROM content.

esg-bsm

Note the time of the error message and examine the logs for IDPROM or software errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-0-UIPEER_CREATE

0-Emergency

Failed to create user interface peer.

The system failed to create a user interface peer.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-3-BSM_SERVICE_SETUP

3-Error

Failed to setup the backplane switch manager (bsm) service

Backplane Switch Manager failed to set itself up as a proxy to the backplane switch.

esg-bsm

Collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-3-CHASFS_OBJECT_DESTROY

3-Error

Failed to destroy chassis filesystem object [chars] because [chars]

A chassis filesystem object that should have been destroyed was not destroyed.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-3-CHASFS_PROPERTY_DESTROY

3-Error

Failed to destroy chassis filesystem proprty [chars]/[chars] because [chars]

A chassis filesystem property that should have been destroyed was not destroyed.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSMRP-3-PEER_INVALID

3-Error

A peer table entry has invalid state.

A peer table entry has an invalid state. This could be due to a software defect or system resource exhaustion.

esg-bsm

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

BSSID_MGR_TRACE_MSG-3-WLC_GEN_ERR_TB

3-Error

Error in [chars]

General Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

BTRACE_MANAGER-3-BTRT_ERR_MSG

3-Error

Btrace Rotate Error: [chars]

Btrace Rotate error message.

iosxe-binos-utils

LOG_STD_ACTION

BTRACE_MANAGER-4-FILTER_CONFIG

4-Warning

Btrace Manager UTF Filter Applied from conf file: [chars]

Btrace Filter Manager

polaris-trace

No action required

BTRACE_MANAGER-7-BTRT_LOG_MSG

7-Debug

Btrace Export: [chars]

Btrace export info

iosxe-binos-utils

No action required

CAC_TRACE_MESSAGE-5-EWLC_GEN_ERR

5-Notice

Call admission control : [chars]

General ewlc Error Message.

iosxe-binos-utils

LOG_STD_ACTION

CAPWAPAC_SMGR_TRACE_MESSAGE-3-DUPLICATE_IP_PORT

3-Error

IP-Port mapped to more than one AP. [chars]

If the APs are behind NAT/PAT, one of the port is possibly mapped to multiple APs. Client may not be able to join this AP

ewlc-ap

If the APs are behind NAT/PAT, kindly check if same port is mapped to multiple APs

CAPWAPAC_SMGR_TRACE_MESSAGE-3-WLC_GEN_ERR

3-Error

Error in [chars]

General ewlc Error Message.

ewlc-ap

LOG_STD_ACTION

CAPWAPAC_SMGR_TRACE_MESSAGE-4-AP_MSG_THRESHOLD

4-Warning

Warning : [chars]

Number of messages in capwap queue crossed the threshold(exceeded or recovered)

ewlc-ap

LOG_STD_NO_ACTION

CAPWAPAC_SMGR_TRACE_MESSAGE-5-AP_JOIN_DISJOIN

5-Notice

AP Event: [chars]

AP Join/Disjoin Event

ewlc-ap

LOG_STD_NO_ACTION

CAPWAPAC_SMGR_TRACE_MESSAGE-6-WLC_APMGR_INFO

6-Information

Info : - [chars]

General Wireless LAN Controller info message

ewlc-ap

LOG_STD_ACTION

CAPWAPAC_TRACE_MSG-2-MAX_SUPPORTED_AP_LIMIT_90PCT_EXCEEDED

2-Critical

90%% ([dec]) of Maximum Supported AP Join Limit: [dec] exceeded

Exceeded 90% of maximum supported AP join limit

ewlc-ap

LOG_STD_ACTION

CAPWAPAC_TRACE_MSG-2-MAX_SUPPORTED_AP_LIMIT_EXCEEDED

2-Critical

Maximum supported AP join limit: [dec] exceeded

Maximum supported AP join limit exceeded

ewlc-ap

LOG_STD_ACTION

CAPWAPAC_TRACE_MSG-3-MAX_AP_LIMIT_REACHED

3-Error

Ap [chars] will be disconnected. Maximum AP Join Limit: [dec] Reached

Maximum AP join limit reached error

ewlc-ap

LOG_STD_ACTION

CAPWAPAC_TRACE_MSG-3-MAX_LICENSE_AP_LIMIT_REACHED

3-Error

Ap [chars] is not allowed to join. Please start reporting licensing to Cisco to get the ACK for resumption of normal operation.

Device is not registered, maximum AP join limit reached error

ewlc-ap

LOG_STD_ACTION

CAPWAPAC_TRACE_MSG-4-EWC_AP_JOIN_DISABLED_DURING_PNP

4-Warning

Attempt by AP [chars] with MAC [chars] to join this controller was rejected due to PnP image download in progress

External AP is not allowed to join when internal AP image upgrade is going on as part of PnP image download

ewcap-image

LOG_STD_ACTION

CAPWAPAC_TRACE_MSG-4-EWC_AP_JOIN_DISABLED_DURING_PREDOWNLOAD

4-Warning

Attempt by AP [chars] with MAC [chars] to join this controller was rejected due to network upgrade

New AP is not allowed to join during network upgrade

ewcap-image

LOG_STD_ACTION

CAPWAPAC_TRACE_MSG-4-EWC_AP_JOIN_DISABLED_WNCDS_CONFIG_INIT_STILL_IN_PROGRESS

4-Warning

Attempt by AP with MAC [chars] to join this controller was rejected as WNCDs config init still in progress

External AP is not allowed to join as WNCD processes are still being initialized with wlan/policy/site configs

ewlc-app-infra

LOG_STD_ACTION

CAPWAPAC_TRACE_MSG-4-EWC_INTERNAL_AP_JOIN_DISABLED_DURING_PNP_NO_PROVISION

4-Warning

Attempt by Internal AP [chars] with MAC [chars] to join this controller was rejected due to PnP Image Dwonload is in progress and PnP Provision is not Done

Internal AP is not allowed to join in PnP image upgrade flow till the PnP Provision is done

ewcap-image

LOG_STD_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_ACTIVE_CHECK_FAILED

3-Error

Unable to determine name of AP running active controller. Please ensure internal AP has joined and try again

Installer needs to check that the configured preferred master matches the current active controller AP name before reloading. However it was unable to determine the active controller AP name, probably because the internal AP has not joined. Please ensure that the internal AP has joined and then try again

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_ACTIVE_NOT_PREFERRED_MASTER

3-Error

The configured preferred master AP name does not match the current active controller AP name. Please configure the preferred master AP name with 'wireless ewc-ap preferred-master' to match the active controller AP name as shown by 'show wireless ewc-ap redundancy summary' and try again

Installer requires that the configured preferred master matches the current active controller AP name before reloading. Please ensure that the preferred master is configured correctly and then try again

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_AP_AP_JOIN_IMAGE_VERSION_DOWNLOAD_ERROR

3-Error

Configured image download profile failed to download version.info; check network and server configuration

Configured image download profile may not be able to download the correct AP images

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_AP_AP_JOIN_IMAGE_VERSION_DOWNLOAD_START_FAILURE

3-Error

Failed to start downloading AP image version with error [chars]

Configured image download profile may not be able to download the correct AP images

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_AP_DWNLD_IMG_MASTER_INTERNAL_AP

3-Error

External download for internal AP cannot start, a previous download has been already performed.

EWC image upgrade workflow requires mandatory download for new image master AP required by the internal AP. If a previous 'install add' has been performed without ativation, an 'install remove' action is needed to clear fully the previous downloads.

ewcap-image

Execute 'install remove profile default', 'clear ap predownload statistics', and retry Network Upgrade

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_AP_EXTERNAL_DOWNLOAD_IN_PROGRESS

3-Error

Controller performs another external transfer, for example a new AP joins the network. Once transfer completed, please try Network Upgrade again

EWC allows only one active image transfer. For an AP join case, such a transfer has to be completed/aborted before a Network Upgrade is started.

ewcap-image

Check 'show ap summary'. If the number of APs is the expected one, update the image download profile to point to the new software version, and retry Network Upgrade

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_AP_GEN_ERR

3-Error

%% Error: [chars]

Network not ready for this install command

iosxe-binos-utils

Try again later

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_AP_NO_SPACE

3-Error

No sufficient space on bootflash for upgrade. Please do 'dir bootflash:' to list and delete unwanted files. Please do 'install remove profile default'.

No sufficient space on flash to hold the image, please do some cleanup on bootflash:

iosxe-binos-utils

Try 'install remove profile default'

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_AP_PREDOWNLOAD_REQUIRES_POLL_CCO_FIRST

3-Error

Please do poll-cco once before starting EWC-AP software predownload via CCO

EWC-AP software prodownload via CCO requires polling CCO first to get suggested/latest software version

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_EWC_INTERNAL_AP_JOIN_IN_PROGRESS

3-Error

Internal AP has not joined the controller. Once internal AP is up, please try Network Upgrade again.

If internal AP is not present Network Upgrade can not start.

ewcap-image

Check 'show ap summary'. Wait for internal AP is present before Network Upgrade start

CAPWAP_IMGDWNLD_TRACE_MESSAGE-3-CAPWAPIMGDWNLD_GEN_ERR

3-Error

%% Error: [chars]

Improper arguments or config

iosxe-binos-utils

Arguments to be changed

CAPWAP_IMGDWNLD_TRACE_MESSAGE-4-CAPWAPIMGDWNLD_EWC_AP_AP_JOIN_IMAGE_VERSION_MISMATCH

4-Warning

Configured image download profile downloads AP image version [chars]; requires AP image version [chars] to join this controller

Configured image download profile does not work for AP join

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-4-CAPWAPIMGDWNLD_EWC_PREMATURE_ACTIVATE

4-Warning

Image predownload is still in progress, 'install activate' might lead to a longer upgrade of the network

Not all APs might have the new image yet

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-5-CAPWAPIMGDWNLD_EWC_AP_AP_LIST_EVENTS

5-Notice

List Event: [chars]

EWC-AP Master/Invalid Master AP list insertion/deletion/reelection Events

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_AP_IMAGE_DELETED

6-Information

AP Event: Downloaded AP image [chars] was deleted

Downloaded AP image deleted

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_AP_IMAGE_WITHOUT_NODE_DELETED

6-Information

AP Event: Downloaded AP image [chars] without image node was deleted

Downloaded AP image deleted from RAM disk

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_AP_JOIN_IMAGE_VERSION_MATCH

6-Information

Configured image download profile downloads AP image version [chars], matching required AP image version to join this controller

Configured image download profile works for AP join

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_DWNLD_COMPLETE_WITHOUT_NODE_DELETED

6-Information

AP Event: External Download complete and deleted for AP image [chars] without image node

Downloaded AP image deleted from RAM disk

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_HARDDISK_CLEANUP

6-Information

corefiles and/or tracelogs have been deleted, [dec] Bytes disk space is freed

corefiles and tracelogs have been deleted

iosxe-binos-utils

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_IMAGE_MMAPED

6-Information

EWC-AP Event: EWC-AP Controller image [chars] mmaped ... Timer started to unmap

EWC-AP Image MMaped in Memory

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_IMAGE_MMAPED_RESET

6-Information

EWC-AP Event: EWC-AP Controller image [chars] already mmaped in memory ... Timer to unmap reset

EWC-AP Image MMaped in Memory

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_IMAGE_MUNMAPPED

6-Information

EWC-AP Event: EWC-AP Controller image [chars] unmapped from memory ... Timer to unmap Stopped

Controller image unmapped from memory

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_PREDOWNLOAD_AP_COUNT_MISMATCH

6-Information

AP Event: Predownload Total AP count [dec], predownloaded AP count [dec]

Predownload Total and Completed AP count mismatched

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_SEND_MASTER_GOING_DOWN

6-Information

Sending master-going-down message to other APs so that they backoff for 5 minutes for existing active controller to be active after reload

To prevent EWC-AP-capable AP's from becoming EWC-AP controller when current controllr goes through reload, send master-going-down message to them so they wait 5 minutes for the current controller to reboot and become controller again

ewcap-image

LOG_STD_NO_ACTION

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-CAPWAPIMGDWNLD_EWC_AP_WRONG_STATE

6-Information

Network upgrade is not in correct state. Please do 'install remove profile default', and try again

Network Upgrade is not in correct state. Please cancel and try again

ewcap-image

Try 'install remove profile default'

CAPWAP_IMGDWNLD_TRACE_MESSAGE-6-TRACE_EXPORT_TEST

6-Information

Btrace log export test event: Testing Log Export Feature

GUI Triggered Flow to test Log Export Feature

ewcap-image

LOG_STD_NO_ACTION

CERT-1-CERT_EXPIRED

1-Alert

Certificate expired

This alert syslog is generated when the certificate used for DTLS/TLS connection towards SD-WAN controller has expired. Control connection to controllers will not come up as a result of this catastrophic failure

vip-certificate

Please contact Cisco TAC

CERT-1-CERT_EXPIRING

1-Alert

Certificate expiring soon. Time remaining: [dec] [chars]

This alert syslog is generated to warn impending certificate expiry

vip-certificate

New certificate should be installed prior to expiring. Please contact Cisco TAC for assistance

CERT-3-CERT_STORE_INIT_FAILED

3-Error

Certificate store init failed

This error syslog is generated when certificate store initialization fails. Control connection to controllers will not come up as a result of this failure

vip-certificate

Please contact Cisco TAC and open a support ticket for this issue

CERT-5-CERT_INSTALLED

5-Notice

A new certificate has been installed

This notice syslog is generated when a new certificate is installed

vip-certificate

No action is required

CERT-5-CERT_UNINSTALLED

5-Notice

Certificate has been uninstalled

This notice syslog is generated when an installed certificate is uinstalled by administrative action

vip-certificate

No action is required

CERT-5-NEW_CSR_GENERATED

5-Notice

New certificate signing request generated

This notice syslog is generated whenever new certificate signing request is generated

vip-certificate

No action is required

CERT-5-ROOT_CA_CRL_INSTALLED

5-Notice

Root CA CRL has been installed

This notice syslog is generated when a root CA Certificate Revocation List is installed

vip-certificate

No action is required

CERT-5-ROOT_CA_CRL_UNINSTALLED

5-Notice

Certificate has been uninstalled

This notice syslog is generated when a root CA Certificate Revocation List is uninstalled by administrative action

vip-certificate

No action is required

CERT-5-ROOT_CERT_CHAIN_INSTALLED

5-Notice

Root certificate chain installed

This notice syslog is generated when a root certificate chain is installed

vip-certificate

No action is required

CERT-5-ROOT_CERT_CHAIN_UNINSTALLED

5-Notice

Root certificate chain uninstalled

This notice syslog is generated when an installed root certificate chain is uninstalled by administrative action

vip-certificate

No action is required

CERT_MGR_ERRMSG-3-CERT_MGR_GENERAL_ERR

3-Error

General error: [chars]

General cert mgr lib error message

ewlc-ap

LOG_STD_ACTION

CERT_MGR_ERRMSG-3-CERT_VALIDATION_ERR

3-Error

Certificate Validation Error, [chars]

General Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

CERT_MGR_ERRMSG-3-FIPS_AUDIT_FIA_X509_EXT_1_ITT_LSC_CA_CERT

3-Error

LSC CA certificate not generated with CA flag true

LSC CA certificate not generated with CA flag true

ewlc-ap

LOG_STD_ACTION

CERT_MGR_ERRMSG-3-FIPS_SUITABILITY_ERR

3-Error

FIPS Compliance: [chars]

General cert mgr lib error message

ewlc-ap

LOG_STD_ACTION

CERT_MGR_ERRMSG-3-PKI_SSL_IPC_RESP_ERR

3-Error

IPC Respone Error, [chars]

General Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

CERT_MGR_ERRMSG-3-WLANCC_UPDATE_ERR

3-Error

Failed to send WLAN CC (Commit Criteria) update to PKI IOSd due to database error

General Wireless LAN Controller Error Message.

ewlc-ap

LOG_STD_ACTION

CERT_MGR_ERRMSG-4-CERT_MGR_WARNING

4-Warning

Warning, [chars]

General Wireless LAN Controller warning message

ewlc-ap

LOG_STD_ACTION

CERT_MGR_ERRMSG-6-FIPS_SUITABILITY_INFO

6-Information

FIPS Compliance: [chars]

General cert mgr lib error message

ewlc-ap

LOG_STD_ACTION

CFGMGR-3-ADMIN_PASSWD_UNCHANGED

3-Error

Failed to set new admin password

This syslog is generated when the default password of admin account is not updated due to an error. This could occur during bootup when the system is initializing

cedge-confd-startup

Please retry updating default password for admin account. If admin password cannot be updated after couple of attempts, please contact Cisco TAC for assistance

CFGMGR-4-ADMIN_PASSWD_CHANGE_DEFERRED

4-Warning

New admin password not set yet, waiting for daemons to read initial config

This syslog is generated when the system is initializing and user tries to update default password of admin account. Once bootup completes, config database is unlocked and admin password can be changed

cedge-confd-startup

This should be a temporary log, if the log continues to be seen on console, please contact Cisco TAC for assistance

CFGMGR-6-ADMIN_PASSWD_CHANGED

6-Information

Successfully set new admin password

This info syslog is generated when the default password of admin account is updated

cedge-confd-startup

No action is required

CFMGR_LOG-4-COUNTRY_CFG_DEPRECATED_CLI

4-Warning

[chars]: 'ap country <coutry-code>' is deprecated, instead use 'wireless country <country-code>'

'ap country <code>' cli has been has been deprecated, Please start using 'wireless country <code>' instead

ewlc-rrm

Please start using new form of cli mentioned in the explanation message

CFMGR_LOG-4-UNSUPPORTED_AP_DTLS_CIPHER

4-Warning

Unsupported AP DTLS ciphersuite: [chars]

Unsupported ciphersuite for AP DTLS in a given security mode

ewlc-ap

No action required

CFMGR_LOG-7-CFG_DOWNLOAD_LOG_MSG

7-Debug

Scheduled Config Download: [chars]

Config Download info

iosxe-binos-utils

No action required

CGM_NGWC-3-NOMEM

3-Error

No Enough Shared Memory in CGM\n

The configuration is too large.

INVALID

Check the existing ACL configuration.\n

CHASFS-3-NOCHASFSDIR

3-Error

The directory [chars] does not exist.

No explanation.

iosxe-chassismgr

LOG_STD_NO_ACTION

CHASFS-3-NOINOTIFY

3-Error

The inotify device could not be opened. Error [dec].

This error occurs when there is an error in the system that prevents the notification facility from being accessed.

iosxe-chassismgr

LOG_STD_NO_ACTION

CHASFS-3-NOOPEN_PROPERTY

3-Error

Error opening chassis file system object [chars]: [chars]

An application was not able to open a an object in its local chassis file system.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CHASFS-3-NORESOLVE_LOCAL_OBJECT

3-Error

Error resolving local FRU object: [chars]

An application was not able to create a reference to an object in its local chassis file system.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CIA-0-CPA_INITIALIZATION

0-Emergency

cpa_init failed, return code: [dec]

cpa_init has failed. This might be because CPA south bound libraries are missing or a mapping of CPA libraries to PD_TYPE missing in cpa_fru_db.conf

iosxe-chassismgr

Review cpa logs

CLIENT_EXCLUSION_AUDIT_MESSAGE-3-FIPS_AUDIT_FTA_TSE_1_CLIENT_ASSOCIATION_REJECTED

3-Error

Client [chars] association rejected and excluded, reason: [chars]

Client association rejected because of excluding

ewlc-client

LOG_STD_ACTION

CLIENT_EXCLUSION_SERVER-5-ADD_TO_EXCLUSIONLIST_REASON

5-Notice

Client [chars] was added to exclusion list, reason: [chars]

Client was added to exclusion list

ewlc-client

Message notification informing about the client was added to exclusion list

CLIENT_EXCLUSION_SERVER-5-ADD_TO_EXCLUSIONLIST_REASON_DYNAMIC

5-Notice

Client [chars] was added to exclusion list associated with AP Name:[chars], BSSID:[chars], reason:[chars]

Client was added to exclusion list

ewlc-client

Message notification informing about the client was added to exclusion list

CLIENT_HA_SVC_MESSAGE-3-EWLC_RECREATE_ERR

3-Error

Heap recreate failure in module [chars]. [chars]

Failure seen during heap recreate

iosxe-binos-utils

LOG_STD_ACTION

CLIENT_IPV6_TRACE_MESSAGE-3-CLIENT_IPV6_CRIT_ERR

3-Error

client_ipv6 Error: [chars]

Client IPv6 Error Message.

iosxe-binos-utils

LOG_STD_ACTION

CLIENT_IPV6_TRACE_MESSAGE-4-CLIENT_IPV6_WARN

4-Warning

client_ipv6 Warning: [chars]

Client IPv6 Warning Message.

iosxe-binos-utils

LOG_STD_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_GTK_UNABLE_TO_UPDATE_BROADCAST_KEYS_TO_CLIENT

3-Error

User ID: [chars] - Unable to update broadcast keys to Client

Unable to update broadcast keys to Client

ewlc-client

LOG_STD_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PMK_DEFLECTION_ATTACK

3-Error

User ID: [chars] - Deflection attack detected from this mobile

Deflection attack detected from this mobile

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PMK_INVALID_KEY_DATA_LEN

3-Error

User ID: [chars] - Invalid key data length

Invalid key data length

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PMK_INVALID_KEY_TYPE

3-Error

User ID: [chars] - Invalid key type

Invalid key type

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PMK_INVALID_MIC

3-Error

User ID: [chars] - Received Invalid MIC in EAPOL Key Message handshake

Received Invalid MIC in EAPOL Key Message handshake

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PMK_INVALID_MIC_IN_M2

3-Error

User ID: [chars] - Received Invalid MIC in EAPOL Key Message M2

Received Invalid MIC in EAPOL Key Message M2

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PMK_INVALID_REPLAY_WINDOW

3-Error

User ID: [chars] - Invalid Replay Window

Invalid Replay Window

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PMK_INVALID_SECURE_BIT

3-Error

User ID: [chars] - Invalid secure bit

Invalid secure bit

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PMK_ZERO_MIC

3-Error

User ID: [chars] - Zero MIC received

Zero MIC received

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_2_PTK_UNABLE_TO_SEND_SESSION_KEY_TO_AP

3-Error

User ID: [chars] - Unable to send Session key to AP

Unable to send Session key to AP

ewlc-client

LOG_STD_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-3-FIPS_AUDIT_FTA_TSE1_DENY_CLIENT_ACCESS

3-Error

User ID: [chars] - - Client association denied as it is not in Active Hours slot [chars]

Received association request in non-active hours

ewlc-client

LOG_STD_RECUR_ACTION

CLIENT_ORCH_AUDIT_MESSAGE-6-FIPS_AUDIT_FIA_8021X_EXT_1_CLIENT_ASSOCIATION_RECEIVED_FROM_MOBILE

6-Information

[chars] [chars]: [chars] Association received from mobile on BSSID [chars] AP [chars]

Association received from mobile on BSSID

ewlc-client

LOG_STD_ACTION

CLIENT_ORCH_GUEST_LAN_LOG-3-CLIENT_JOIN_FAILED

3-Error

Wired Guest client [chars] failed joining on vlan [dec] physical interface [chars]. Reason: [chars]

Wired Guest client failed joining

ewlc-client

If this message occurs, client failed joining and was deleted.

CLIENT_ORCH_GUEST_LAN_LOG-3-CLIENT_JOIN_FAILED_NO_MAC

3-Error

Refusing creation of wired Guest client with no MAC on vlan [dec] physical interface [dec].

Wired Guest client failed joining

ewlc-client

If this message occurs, client failed joining and was deleted.

CLIENT_ORCH_GUEST_LAN_LOG-5-CLIENT_JOIN_IGNORED

5-Notice

Already existing client [chars] join request on vlan [dec] and physical interface [chars] was ignored

A request to join the client was ignored because the client is already connected

ewlc-client

No action is required

CLIENT_ORCH_GUEST_LAN_LOG-7-CLIENT_RECEIVED

7-Debug

Wired Guest Client [chars] join request received on vlan [dec] - interface [chars]

New Wired Guest client join received

ewlc-client

No action is required

CLIENT_ORCH_LOG-3-CLIENT_TRACEBACK

3-Error

Error in [chars]

General Client Error Message.

ewlc-client

LOG_STD_ACTION

CLIENT_ORCH_LOG-4-ANCHOR_INVALID_MBSSID

4-Warning

Export anchor required but config is incorrect (e.g.: wlan should be up, wlan profile name and policy profile name should match) for: Wlan-Profile: [chars], Policy Profile: [chars], client [chars]

Export anchor required but config is incorrect (e.g.: wlan should be up, wlan profile name and policy profile name should match)

ewlc-guest

If this message occurs, it implies that Wlan needs to be up or wlan profile name and policy profile name need to match

CLIENT_ORCH_LOG-4-ANCHOR_INVALID_WLAN_ID

4-Warning

Export anchor required but unable to get wlan id for: Wlan-Profile: [chars], Policy Profile: [chars], client [chars]

Export anchor required but unable to get wlan id

ewlc-guest

If this message occurs, it implies that Wlan name is not configured

CLIENT_ORCH_LOG-4-ANCHOR_NOT_EXPORT_WLAN

4-Warning

Export anchor required but wlan not configured as mobility export anchor for: Wlan-Profile: [chars], Policy Profile: [chars], client [chars]

Export anchor required but wlan not configured as mobility export anchor

ewlc-guest

If this message occurs, it implies that Wlan is not configured as mobility export anchor

CLIENT_ORCH_LOG-4-ANCHOR_VAP_SECURITY_MISMATCH

4-Warning

Export anchor required but local and remote security/profile configuration is not matching for: Wlan-Profile: [chars], Policy-Profile: [chars] client [chars]

Export anchor required but local and remote security/profile configuration (wlan and/or policy profile) is not matching

ewlc-guest

If this message occurs, it implies that local and remote wlan and policy profiles need to have the same security or configuration settings

CLIENT_ORCH_LOG-4-ANCHOR_WEBAUTH_ON_MAB_NOT_CONFIGURED

4-Warning

Export anchor: webauth on mac failure configuration mismatch between anchor and foreign for: Wlan-Profile: [chars], Policy Profile: [chars], client [chars]

Webauth on Mac Failure configuration mismatch between anchor and foreign

ewlc-guest

If this message occurs, it implies that Wlan on anchor or foreign is not configured for webauth on mac failure

CLIENT_ORCH_LOG-5-ADD_TO_EXCLUSIONLIST_MAC_THEFT_REASON

5-Notice

Client [chars] with IP: [chars] was added to exclusion list, legit ifid: 0x%08x, current ifid: 0x%08x, reason: [chars]

Blacklisting client on MAC address theft.

ewlc-client

If this message occurs, it implies that there was MAC address theft.

CLIENT_ORCH_LOG-5-ADD_TO_EXCLUSIONLIST_REASON

5-Notice

Client [chars] with IP: [chars] was added to exclusion list, legit Client [chars], IP: [chars], reason: [chars]

Blacklisting client on IP address theft or MAC address theft or IP and MAC address theft.

ewlc-client

If this message occurs, it implies that there was IP theft or MAC address theft or IP and MAC address theft.

CLIENT_ORCH_LOG-5-EASYPSK_CLIENT_DELETED

5-Notice

Easy-PSK client [chars] : client deleted due because AAA exchange failed reason [chars].

Easy-PSK client was deleted because of AAA Exchange failure.

ewlc-client

If this message occurs, it implies that client was deleted due to AAA exchange failure.

CLIENT_ORCH_LOG-5-WEBAUTH_ON_MAB_FAILURE_ROAMING_DENIED

5-Notice

Client [chars] : Roaming denied, reason: [chars]

Roaming denied for Webauth on MAB failure client.

ewlc-client

If this message occurs, it means that roaming occurred with controllers with different MAC authentication lists.

CLIENT_ORCH_LOG-6-CLIENT_ADDED_TO_RUN_STATE

6-Information

Username entry ([chars]) joined with ssid ([chars]) for device with [chars] on channel ([dec])

Details for client when it goes to run state

ewlc-client

If this message occurs, it implies that client successfully went to RUN state

CLIENT_ORCH_LOG-7-CLIENT_IP_UPDATED

7-Debug

Username ([chars]), [chars], IP [chars]IP address updated, [chars] to AP ([chars]) with SSID ([chars])

Details for client when it goes to run state

ewlc-client

If this message occurs, it implies that client successfully went to RUN state

CLIENT_ORCH_LOG-7-CLIENT_MOVED_TO_DELETE_STATE

7-Debug

Username ([chars]), [chars], IP [chars]disconnected from AP ([chars]) with SSID ([chars])

Details for client when it goes to delete state

ewlc-client

If this message occurs, it implies that client successfully went to DELETE state

CLIENT_ORCH_LOG-7-CLIENT_MOVED_TO_RUN_STATE

7-Debug

Username ([chars]), [chars], IP [chars][chars] to AP ([chars]) with SSID ([chars]) on channel ([dec])

Details for client when it goes to run state

ewlc-client

If this message occurs, it implies that client successfully went to RUN state

CLIENT_ORCH_VLAN_OVERRIDE_LOG-7-CLIENT_VLAN_OVERRIDE

7-Debug

Client [chars] on wlan [chars] and policy profile [chars] received a vlan override after web-authentication and it is moved to the new VLAN to learn a new IP

The client received a vlan override after web-authentication

ewlc-client

No action is required

CLIENT_ORCH_VLAN_OVERRIDE_LOG-7-CLIENT_VLAN_OVERRIDE_TIMEOUT

7-Debug

Client [chars] on wlan [chars] and policy profile [chars] failed to re-associate and learn a new IP after the VLAN Override and is deleted

The client needs to re-associate within 30s after a vlan override otherwise it is deleted.

ewlc-client

No action is required

CLIENT_ORCH_VLAN_OVERRIDE_LOG-7-FOREIGN_CLIENT_VLAN_OVERRIDE

7-Debug

Export foreign client [chars] on wlan [chars] and policy profile [chars] received a vlan override from export anchor

The export foreign client received a vlan override from anchor

ewlc-client

No action is required

CLOUDM_ONBOARDING_DRAGONFLY-3-CLOUDM_ONBOARDING_HTTPCON_ERROR

3-Error

[chars] with HTTP connection error: [chars].

received an httpcon error while onboarding controller

cloudm

LOG_STD_NO_ACTION

CLOUDM_ONBOARDING_DRAGONFLY-3-CLOUDM_ONBOARDING_HTTP_ERROR

3-Error

[chars] with HTTP status code [dec].

received an http error while onboarding controller

cloudm

LOG_STD_NO_ACTION

CLOUDM_ONBOARDING_DRAGONFLY-6-CLOUDM_ONBOARDING_SUCCESS

6-Information

Successfully [chars]

Successfully onboarded, otp updgraded, or received access token for device

cloudm

LOG_STD_NO_ACTION

CLOUDM_ONBOARDING_SPACES-3-CLOUDM_ONBOARDING_SPACES_AUTH_TOKEN_ERR

3-Error

Cisco Spaces persistent credentials could not be installed for [chars]

Spaces persistent credential installation went through errors

cloudm

If this message occurs, it means persistent credentials for Spaces could not be installed for errors

CLOUDM_ONBOARDING_SPACES-3-CLOUDM_ONBOARDING_SPACES_OTP_INSTALL_ERR

3-Error

Cisco Spaces OTP could not be installed for [chars]

Spaces OTP installation went through errors

cloudm

If this message occurs, it means OTP for Spaces could not be installed for errors

CLOUDM_ONBOARDING_SPACES-6-CLOUDM_ONBOARDING_SPACES_ACCESS_TOKEN

6-Information

Cisco Spaces access token has been updated.

Updated access token for Spaces

cloudm

If this message occurs, it means access-token for Spaces have been installed

CLOUDM_ONBOARDING_SPACES-6-CLOUDM_ONBOARDING_SPACES_ACCESS_TOKEN_ERR

6-Information

Cisco Spaces access token could not be installed for [chars]

Spaces access token installation went through errors

cloudm

If this message occurs, it means access token for Spaces could not be installed for errors

CLOUDM_ONBOARDING_SPACES-6-CLOUDM_ONBOARDING_SPACES_AUTH_TOKEN

6-Information

Cisco Spaces persistent credentials have been installed

Installed persistent client-credentials for Spaces

cloudm

If this message occurs, it means client-credentials for Spaces have been installed

CLOUDM_ONBOARDING_SPACES-6-CLOUDM_ONBOARDING_SPACES_OTP_INSTALL

6-Information

Cisco Spaces OTP has been installed

Installed OTP for Spaces

cloudm

If this message occurs, it means OTP for Spaces has been installed

CLOUDM_TEST-6-HTTP_RESPONSE

6-Information

Completed: [chars]

Result of the test request

iosxe-ui

LOG_STD_NO_ACTION

CLUSTERMGR-1-PLATFORM_MISMATCH

1-Alert

\n Platform mismatch detected. A stack cannot be formed with peer switch: [chars]

The peer switch is incompatible and cannot join the stack.

polaris-clustering

Replace peer switch with platform compatible switch

CLUSTERMGR-1-RELOAD

1-Alert

\n Reloading due to reason [chars]

The specified switch has received a reload request and is being reloaded.

polaris-clustering

No action is required

CLUSTERMGR-6-DUAL_ACTIVE_CFG_MSG

6-Information

\n Dual Active Detection [chars]

Switch detected availability or unavailability of Dual Active Detection ports.

polaris-clustering

No action is required

CMAN_IDPROM_ENVMON-3-CMAN_IDPROM_FIELD_INVALID

3-Error

The idprom contains an invalid environmental monitoring field.

If this error occurs then parsing of the environmental monitoring data is aborted. Environmental monitoring will be either incomplete or absent entirely.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMAN_INIT-1-CMAN_BOOT_FAIL

1-Alert

CMAN: [chars]\n

CMAN Initialization has failed.

iosxe-chassismgr

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

CMAN_INIT-1-CMAN_INIT_FAIL

1-Alert

CMAN: [chars]\n

CMAN Initialization has failed.

iosxe-chassismgr

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

CMAN_LED-6-BEACON_LED_TURNED

6-Information

Slot [dec] Beacon LED turned [chars]

Beacon LED turned ON/OFF. This is a notification message only.No action is required.

iosxe-chassismgr

This is a notification message only. No action is required.

CMAN_LED-6-CHASSIS_BEACON_LED_TURNED

6-Information

Chassis Beacon LED turned [chars]

Beacon LED turned ON/OFF. This is a notification message only.No action is required.

iosxe-chassismgr

This is a notification message only. No action is required.

CMAN_NYQ-1-CMAN_INIT_FAIL

1-Alert

CMAN: [chars]\n

CMAN Initialization has failed.

iosxe-chassismgr

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

CMAN_SEM-2-SEM_ERR

2-Critical

SEM event has occurred in device [chars]. Event code: [dec]

A Single Event Upset (SEU) event has occurred in one of the FPGA. These events may occur at any point of time, but are considered to be rare.

iosxe-chassismgr

If the error is seen only once, there is no need for anything to be done. If these errors are appearing continuously/persistently, please copy over the logs as they appear in the console, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

CMAN_THERMAL-1-THERMAL_GREEN_THRESHOLD

1-Alert

Hotspot temperature has exceeded GREEN threshold\n

The switch is too cold.

iosxe-chassismgr

Check the switch's environment is a safe operating temperature. If problem persists, replace the switch.

CMAN_THERMAL-1-THERMAL_RED_THRESHOLD

1-Alert

Hotspot temperature has exceeded RED threshold. Switch will shutdown soon.\n

The hotspot temperature is critically overheated. The switch will soon shutdown to prevent permanent damage.

iosxe-chassismgr

Check the switch's environment is a safe operating temperature. If problem persists, replace the switch.

CMAN_THERMAL-2-THERMAL_YELLOW_THRESHOLD

2-Critical

Hotspot temperature has exceeded YELLOW threshold\n

The hotspot temperature is too high. Improve cooling immediately.

iosxe-chassismgr

Check the switch's environment is a safe operating temperature. If problem persists, replace the switch.

CMCC-0-C2W_INITIALIZATION

0-Emergency

The SIP C2W has failed initialization because [chars]

The C2W bus on the SIP is used to read the shared port adapter (SPA) IDPROM. This error indicates that the SIP C2W bus failed to initialize.

iosxe-chassismgr

Examine the logs for C2W driver errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASFS_LOCATION_TRANSLATE

0-Emergency

Failed to translate a location to a chasfs object name because [chars]

The system failed to translate a data sensor location to the chassis filesystem (CHASFS) module. This error could be caused by a software defect.

iosxe-chassismgr

Restart the SIP. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASFS_OBJECT_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] because [chars]

The system failed to create a chassis filesystem object. This error could be caused by a software defect or a filesystem failure.

iosxe-chassismgr

Restart the SIP. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASFS_OBJECT_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] not present.

The system was unable to find an expected chassis filesystem object. This error could be caused by a software defect or a filesystem failure.

iosxe-chassismgr

Restart the SIP. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASFS_OBJECT_WATCH

0-Emergency

Failed to watch chassis filesystem object [chars] because [chars]

The system failed to watch a chassis filesystem object. This error could be caused by a software defect or a filesystem failure.

iosxe-chassismgr

Restart the SIP. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASFS_PROPERTY_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] property [chars] because [chars]

The system failed to create a chassis filesystem object property. This error could be caused by a software defect or a filesystem failure.

iosxe-chassismgr

Restart the SIP. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASFS_PROPERTY_GET

0-Emergency

Failed to read chassis filesystem object [chars] property [chars] because [chars]

The system failed to read a chassis filesystem object property. This error could be caused by a software defect or a filesystem failure.

iosxe-chassismgr

Restart the SIP. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASFS_PROPERTY_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] property [chars] not present.

The system cannot locate a chassis filesystem object property. This error could be caused by a software defect or a filesystem failure.

iosxe-chassismgr

Restart the SIP. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASFS_PROPERTY_SET

0-Emergency

Failed to write chassis filesystem object [chars] property [chars] because [chars]

The system failed to write a chassis filesystem object property. This error could be caused by a software defect or a filesystem failure.

iosxe-chassismgr

Restart the SIP. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CHASSIS_TYPE

0-Emergency

The chassis type [chars] is invalid.

The system has detected an invalid chassis type. This error could be caused by a hardware defect, software defect, or incorrect IDPROM content.

iosxe-chassismgr

Examine the logs for IDPROM or hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CPLD_INITIALIZATION

0-Emergency

The SIP CPLD has failed initialization :[chars]

A SIP complex programmable logic device (CPLD) failed to initialize. This error could be caused by a hardware or software driver defect.

iosxe-chassismgr

Examine the logs for CPLD driver or hardware errors. Verify that the software and CPLD versions are compatible.

CMCC-0-CPLD_INTR_ENABLE

0-Emergency

The CPLD initialization has failed because [chars]

The CPLD interrupt enable failed to initialize. This error could be caused by a hardware defect or CPLD driver defect.

iosxe-chassismgr

Examine the logs for CPLD driver or hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-CPLD_IOCTL

0-Emergency

A CPLD driver I/O control has failed because [chars]

A complex programmable logic device (CPLD) I/O driver control has failed. This error could be caused by a hardware or software driver defect.

iosxe-chassismgr

Examine the logs for CPLD driver and hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information

CMCC-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMCC-0-FLOW_CONTROL_MBE

0-Emergency

Multi-bit ECC error seen, Cause [chars], MIP100 is going to be reloaded to recover

Non correctable multi bit errors were detected in the FPGA.

iosxe-chassismgr

MIP100 is reloaded to correct the error. If the problem persists, the MIP100 hardware may need to be replaced.

CMCC-0-FPGA_INITIALIZATION

0-Emergency

The CC has failed initialization because [chars]. Reloading the card

The FPGA on the carrier card has failed to initialize. This error could be caused by a hardware

iosxe-chassismgr

Examine the driver logs or hardware errors. Decode the core accompanied with this error.

CMCC-0-HTDP_ENABLE

0-Emergency

The HTDP initialization has failed because [chars]

The Hypertransort datapath failed to initialize. This error could be caused by a hardware defect or HTDP driver defect.

iosxe-chassismgr

Examine the logs for HTDP driver or hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-HT_INITIALIZATION

0-Emergency

The SIP HyperTransport has failed initialization because [chars]

A SIP HyperTransport (HT) CPU bus failed to initialize. This error could be caused by a hardware defect or HT driver defect.

iosxe-chassismgr

Examine the logs for HT driver or hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-HT_IOCTL

0-Emergency

A SIP HyperTransport driver I/O control has failed because [chars]

A physical layer interface module (PLIM) HyperTransport (HT) driver I/O has failed. This error could be caused by a hardware defect or HT driver defect.

iosxe-chassismgr

Examine the logs for HT driver or hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-IPC_CONNECTION_INVALID

0-Emergency

An IPC connection has invalid state.

An inter-process communication (IPC) connection has an invalid state. This error could be caused by a software defect or system resource limitation.

iosxe-chassismgr

Restart the SIP.

CMCC-0-IPC_CONNECT_MASTER

0-Emergency

IPC connection to the active RP failed because [chars]

The inter-process communication (IPC) connection to the active route processor (RP) failed. This error could be caused by a software defect or system resources limitation.

iosxe-chassismgr

Restart the SIP.

CMCC-0-IPC_INITIALIZATION

0-Emergency

IPC initialization failed because [chars]

An inter-process communication (IPC) initialization failed. This error could be caused by a software defect or system resource limitation.

iosxe-chassismgr

Restart the SIP.

CMCC-0-PCI_RESCAN

0-Emergency

The PCIE bus could not be rescanned because [chars]

The PCIE bus failed to rescan. This error could be caused by a hardware defect, software driver defect, or improper internal configuration.

iosxe-chassismgr

Examine the logs for PCIE bus driver and hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information

CMCC-0-PEER_INVALID

0-Emergency

A peer table entry has invalid state.

An invalid state occurred in a peer table entry. This error could be caused by a software defect or system resource limitation.

iosxe-chassismgr

Restart the SIP.

CMCC-0-PLIM_HALT

0-Emergency

A PLIM driver has critical error [chars], [dec], param %x param %x

A physical layer interface module (PLIM) HyperTransport (HT) driver I/O has failed. This error could be caused by a hardware defect or an HT driver defect.

iosxe-chassismgr

Restart the SIP. If the problem persists, you may need to replace the PLIM.

CMCC-0-PLIM_INITIALIZATION

0-Emergency

The PLIM has failed initialization because [chars]

The physical layer interface module (PLIM) failed to initialize. This error could be caused by a hardware defect or a PLIM driver defect.

iosxe-chassismgr

Examine the logs for PLIM driver or hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-PLIM_IOCTL

0-Emergency

A PLIM driver I/O control has failed because [chars]

A physical layer interface module (PLIM) driver I/O has failed. This error could be caused by a hardware defect or a PLIM driver defect.

iosxe-chassismgr

Examine the logs for PLIM driver or hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMCC-0-SERDES_INITIALIZATION

0-Emergency

The SIP Serial Bridge ASIC has failed initialization because [chars]

The SIP serial bridge ASIC failed to initialize. This error could be caused by a hardware defect, software driver defect, or improper internal configuration.

iosxe-chassismgr

Examine the logs for serial bridge ASIC driver and hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information

CMCC-0-SERVICES_INITIALIZATION

0-Emergency

Failed to initialize general application services because [chars]

The system failed to initialize certain application services. This error could be caused by a software defect or system resource limitation.

iosxe-chassismgr

Restart the SIP.

CMCC-0-UIPEER_CREATE

0-Emergency

Failed to create user interface peer.

The system failed to create a user interface peer. This error could be caused by a software defect or system resource limitation.

iosxe-chassismgr

Restart the SIP.

CMCC-2-BAD_ID_HW

2-Critical

Failed Identification Test in [chars]. The module [chars] on the slot [dec] may not be a genuine Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco memory, WIC cards, AIM cards, Network Modules, SPA cards, GBICs or other modules into a Cisco product is the cause of a support issue, Cisco may deny support under your warranty or under a Cisco support program.

Hardware in the specified location could not be identified as a genuine Cisco product

cbr-platform-infra

Replace the hardware with a genuine Cisco product. If this message recurs, contact your Cisco technical support representative and provide the representative with the gathered information

CMCC-2-BAD_ID_HW_SLOT_STR

2-Critical

Failed Identification Test in [chars]. The module [chars] on the [chars] may not be a genuine Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco memory, WIC cards, AIM cards, Network Modules, SPA cards, GBICs or other modules into a Cisco product is the cause of a support issue, Cisco may deny support under your warranty or under a Cisco support program.

Hardware in the specified location could not be identified as a genuine Cisco product

iosxe-chassismgr

Replace the hardware with a genuine Cisco product. If this message recurs, contact your Cisco technical support representative and provide the representative with the gathered information

CMCC-2-CC_SPA_MOVE_SM

2-Critical

***** CMCC SPA SM was strucked for a minute in state: s_kill_wait for slot [dec], moving the state machine

CMCC SPA SM was strucked for a minute in state: s_kill_wait for the line card.

iosxe-chassismgr

move the cmcc spa state machine.

CMCC-2-CC_SPA_PSM_READY_NOT_RCVD

2-Critical

***** CMCC did not received PSM READY event [dec] sec for slot [dec].

CMCC SPA SM was not received PSM READY for 100 sec.

iosxe-chassismgr

do remove hard.

CMCC-2-CC_SPA_STRUCK

2-Critical

***** CMCC SPA SM was strucked for [dec] seconds for slot [dec].

CMCC SPA SM was strucked for a minute in state: s_kill_wait for the line card.

iosxe-chassismgr

move the cmcc spa state machine.

CMCC-2-FRU_HWPRG_UPG_FAILED

2-Critical

Failed to [chars] [chars] hardware programmable on [chars] in [chars].

Upgrade hw-programmable failed to upgrade the CPLD/FPGA firmware on the given FRU

iosxe-chassismgr

Reload the card and retry to program the hw-programmable. If the card fails to come up please contact TAC

CMCC-2-FRU_HWPRG_UPG_SUCCESS

2-Critical

Success to [chars] [chars] hardware programmable on [chars]. Please execute the POST Upgrade CLI: upgrade hw-programmable cable <r0/r1> daybreak post-upgrade slot <slot> to finish the upgrade process

Upgrade hw-programmable success to upgrade the CPLD/FPGA firmware on the given FRU

iosxe-chassismgr

No action is required. This is informational message

CMCC-2-FRU_IOFPGA_UPG_FAILED

2-Critical

Failed to upgrade field programmable device on [chars] in slot [dec].

Upgrade of field programmable device failed

iosxe-chassismgr

Reload the card and retry to program the field programmable device. If the card fails to come up please contact TAC

CMCC-2-FRU_IOFPGA_UPG_LC_PWR_CYCLE_DONE

2-Critical

Power cycled the [chars] in slot [dec], after FPGA upgrade.

Power cycled the card after FPGA upgrade.

iosxe-chassismgr

Line card has been power cycled after FPGA upgrade.

CMCC-2-FRU_IOFPGA_UPG_SUCCESS

2-Critical

Successfully upgraded the field programmable device on [chars] in slot [dec]. Power-cycling the line card.

Upgrade field programmable device was successful on the given FRU. Line card needs to be power-cycled or removed and re-inserted for upgrade to take effect.

iosxe-chassismgr

Line card needs to be power cycled or removed and re-inserted for the upgrade to take effect.

CMCC-2-FRU_LC_PWR_RESET

2-Critical

***** Detected power reset for the Line card in slot [dec]. To recover from the error, Line card will brought up shortly

Detected Auto power reset(may be HW issue) for the Linecard.

iosxe-chassismgr

Pseudo OIR of the Line card has been to recover/bring up the card.

CMCC-3-C2W_READ

3-Error

An C2W read has failed because [chars]

An attempt to read the C2W bus has failed. This error could be caused by a hardware or software defect.

iosxe-chassismgr

Examine the logs for C2W driver errors.

CMCC-3-C2W_WRITE

3-Error

An I2C write has failed because [chars]

An attempt to write to the inter-integrated circuit (I2C) has failed. This error could be caused by a hardware or software defect.

iosxe-chassismgr

Examine the logs for I2C driver errors.

CMCC-3-CARD_MISMATCH

3-Error

The CONFIG&PICTYPE in slot [dec] mismatch : CONFIG : [chars], PIC : [chars]

The CMD and PIC in the slot mismatch.

iosxe-chassismgr

Shut down the LC and change the card mode or remove the pic card.

CMCC-3-CC_HOTSWAP_CKT_FAIL

3-Error

Hot Swap Circuit has failed for bay [dec]

The Hot Swap Circuit for the SPA bay has been tripped. This error could be caused by bad SPA or CC hardware.

iosxe-chassismgr

Examine the CMCC and PSM OIR logs. Verify whether the recovery reload could bring up the SPA

CMCC-3-DDR_SINGLE_BIT_ERROR

3-Error

Single-bit DRAM ECC error: mme: [dec], sbe: [dec], address: 0x%08X, pid: [dec], name: [chars]

The SIP DRAM experienced a single-bit error checking code (ECC) error.

iosxe-chassismgr

No action is required. This error is usually self-correcting. If the problem persists, you may need to replace the SIP.

CMCC-3-FLOW_CONTROL_SBE

3-Error

Single-bit ECC error seen, Cause [chars]

Self correctable single bit errors were detected in the FPGA

iosxe-chassismgr

This error is usually self-correcting. If the problem persists, the MIP100 hardware may need to be replaced.

CMCC-3-FPGA_FAIL

3-Error

[chars] FPGA error detected: [chars]

A SIP field programmable logic device failure detected. This error could be caused by a hardware or software driver defect.

iosxe-chassismgr

Examine the logs for FPGA driver or hardware errors. Verify that the software and firmware versions are compatible.

CMCC-3-HB_TIMEOUT

3-Error

Periodic Heartbeat message from RP timed out.

RP sends periodic heartbeat message to the SIP. The SIP did not receive this heartbeat message for last timeout period.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-HT_DETACH

3-Error

The SIP HyperTransport has failed detachment because [chars]

A SIP HyperTransport (HT) CPU bus failed to detach from software during SIP MDR. This error could be caused by a hardware defect or HT driver defect.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-IDPROM_ACCESS

3-Error

Failed access or process an IDPROM because [chars]

The system failed to access an IDPROM or an IDPROM process failed. This error could be caused by a hardware defect, software defect, or incorrect IDPROM content.

iosxe-chassismgr

Examine the logs for IDPROM or hardware errors.

CMCC-3-IDPROM_SENSOR

3-Error

One or more sensor fields from the idprom failed to parse properly because [chars].

One or more IDPROM sensors failed to parse. This error most likely occurred because of a checksum failure in the IDPROM.

iosxe-chassismgr

Examine the logs for IDPROM or hardware errors.

CMCC-3-INCOMPATIBLE_STANDBY_SUPERVISOR

3-Error

Standby supervisor in slot [dec] is not compatible with the Active supervisor; Standby Supervisor will be reloaded.

Supervisor found in Standby slot may not be fully compatible with the active supervisor and may cause issues.

iosxe-chassismgr

Use supervisors with the same specifications to enable High Availablitly features.

CMCC-3-LC_FPGA_UPGRADE_FAIL

3-Error

The FPGA upgrade request for linecard in switch [dec] slot [dec] failed.

Upgrade of FPGA on the linecard failed

iosxe-chassismgr

Reload the card and retry to program the field programmable device. If the card fails to come up please contact TAC

CMCC-3-LC_FPGA_UPGRADE_PWR_CYCLE_FAIL

3-Error

Power cycle failed for the linecard in switch [dec] slot [dec], after FPGA upgrade.

Power cycle failed for the linecard after FPGA upgrade.

iosxe-chassismgr

OIR the card and retry to program the field programmable device. If the card fails to come up please contact TAC

CMCC-3-MASTERSHIP_WATCH

3-Error

Failed to initialize a watch on the active rp because [chars]

The cc process has failed to setup a watch on the rp chasfs active-rp property. This error is likely caused by a problem with chasfs as a whole.

iosxe-chassismgr

Examine the logs to determine the exact reason for the failure.

CMCC-3-MESSAGE_RESPONSE

3-Error

An invalid message response was received because [chars]

An invalid message response was received. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMCC-3-NETWORK_CLOCK_CAL_FAIL

3-Error

The SIP network clock jitter attenuator calibration fails

The SIP network clock jitter attenuator calibration can not complete within certain time. This would incur some SPA LOS alarms or other error events for some SPA port types.

iosxe-chassismgr

Restart the SIP

CMCC-3-NETWORK_CLOCK_CAL_START

3-Error

The SIP network clock jitter attenuator is calibrating

The SIP network clock jitter attenuator is calibrating after device initilization stage.

iosxe-chassismgr

Restart the SIP if SPA LOS alarms are seen after this.

CMCC-3-NETWORK_CLOCK_DH

3-Error

The SIP network clock jitter attenuator has entered digital holdover

A SIP network clock jitter attenuator has entered digital holdover mode and certain SPAs may report LOS alarms.

iosxe-chassismgr

Restart the SIP.

CMCC-3-NETWORK_CLOCK_LOS

3-Error

The SIP network clock jitter attenuator has lost signal

A SIP network clock jitter attenuator has lost signal from the WAN PLL and certain SPAs may report LOS alarms.

iosxe-chassismgr

Restart the SIP.

CMCC-3-PLIM_DETACH

3-Error

The PLIM has failed detachment from software because [chars]

The physical layer interface module (PLIM) failed to detach from software. This error could be caused by a hardware defect or a PLIM driver defect.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-PLIM_RESTART

3-Error

The PLIM has failed to restart because [chars]

The physical layer interface module (PLIM) failed to restart during SIP MDR. This error could be caused by a hardware defect or a PLIM driver defect.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-PLIM_STATUS

3-Error

A PLIM driver informational error [chars], block %x count %x

A physical layer interface module (PLIM) HyperTransport (HT) driver I/O has failed. This error could be caused by a hardware defect or an HT driver defect.

iosxe-chassismgr

Examine the logs for PLIM or hardware errors.

CMCC-3-SCOOBY_ILAK_FAIL

3-Error

Failed to bringup the Interlaken interface. Cause: [chars]

Interlaken Rx or Tx failed for this card. This error could be caused by a hardware or software driver defect.

iosxe-chassismgr

Reload the Linecard. If the problem still persists, replace the Linecard.

CMCC-3-SIP_MDR_FAIL

3-Error

The SIP failed Minimal Disruptive Restart because [chars]

The SIP failed Minimal Disruptive Restart. Minimal Disruptive Restart process is aborted and an attempt will be made to recover the SIP by resetting the SIP hardware.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-SPA_HOTSWAP_CKT_FAIL

3-Error

SPA on bay [dec] has tripped the Hot Swap Circuit during power-up.

The Hot Swap Circuit for te SPA bay has been tripped. This error could be caused by bad SPA hardware.

iosxe-chassismgr

Examine the CMCC and PSM OIR logs. Verify whether the recovery reload could bring up the SPA

CMCC-3-SPA_MDR_FAIL

3-Error

The SPA in bay [dec] failed Minimal Disruptive Restart because [chars]

The SPA in bay %u failed Minimal Disruptive Restart. Minimal Disruptive Restart process is aborted and an attempt will be made to recover the SPA by resetting the SPA hardware.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-SPA_ONLINE_REQ_TERMINATE

3-Error

The online request for SPA in subslot [dec]/[dec] was terminated because [chars]

The online request for SPA in subslot %d/%u was terminated.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-SPA_PSEUDO_HARD_OIR_VFT_NOT_IMPLEMENTED

3-Error

The PSEUDO OIR VFT is not implemented for bay [dec]

The pseudo OIR vft not implemented for this platform

iosxe-chassismgr

Do nothing

CMCC-3-SPA_SOFT_STOP_FAIL

3-Error

The SPA in bay [dec] could not be soft stopped because [chars]

The SPA in bay %u could not be soft stopped. An attempt will be made to recover the SPA by resetting the SPA hardware.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-SSD_PIDA_OIR

3-Error

Hot insertion/removal of SSD module in [dec]/[dec] not supported. Please reload the router with SSD module installed in bay 3

Hot swapping of SSD is not supported

iosxe-chassismgr

Reload the router with SSD module installed in bay 3.

CMCC-3-STANDBY_EOBC_LINK_ERROR

3-Error

Standby EOBC link error detected.

Standby EOBC link error: either link state is down, or duplexity is not full, or speed is not 1Gbps.

iosxe-chassismgr

Examine the system hardware. Re-seat and securely screw in all FRUs. If the problem persists, please contact TAC support.

CMCC-3-UNKNOWN_3RDPARTY_MODULE

3-Error

Unknown 3rd-party module was inserted in subslot [dec]/[dec]. please check whether the 3rdparty-mode is configured for this subslot

Unknown 3rd-party module was inserted in the given subslot.

iosxe-chassismgr

Examine the system logs for errors.

CMCC-3-UNKNOWN_SPA_LC

3-Error

Unknown SPA was inserted in slot [dec]

Unknown SPA was inserted in the given slot.

iosxe-chassismgr

Remove the unsupported SPA line card and upgrade the software as needed.

CMCC-3-UNSUPPORTED_LC_TYPE

3-Error

An unsupported card of type [chars] is inserted in slot [dec] of the chassis. Remove the card from the chassis or upgrade to an image which supports the card

Unsupported line card was inserted in the given slot.

iosxe-chassismgr

Remove the unsupported SPA line card and upgrade the software as needed.

CMCC-5-C9400X_LC

5-Notice

C9400X-SUP-2 supports 240G per slot with [chars] installed in Slot [dec]

Informational message that 480G Linecard is installed in the chassis with Supervisor card that supports only 240G per slot.

iosxe-chassismgr

Informational notification. No action is required.

CMCC-5-CMCC_EZMAN_HB_MISS_EXCEED

5-Notice

CMCC Missed [dec] Heartbeats from EZMAN, Reloading the Line Card

CMCC Monitors the Health of the EZMAN by keeping a track of the Heartbeat messages. In case the EZMAN gets stuck in a event under watchdog disable context (sw_wdog_disbale), then the CMCC will stop getting these updates. The CMCC after a certain period of time would reset the card, since EZMAN is unresponsive

asr1k-ether-lc

Reload the card, a software initated to restart the EZMAN

CMCC-5-SERDES_BLOCK_EVENT

5-Notice

A SerDes link informational error [chars], block %x count %x

A serial bridge I/O event has occurred. This event is not serious but is logged for diagnostic purposes.

iosxe-chassismgr

No user action is required.

CMCC-5-SERDES_RX_RESET_EVENT

5-Notice

Interlaken Rx Alignment Status [chars], Retry Count [dec]

Rx Sync Failed for Interlaken, Status Timer Expired. So, Resetting the Rx Interlaken Core

asr1k-chassismgr

No user action is required.

CMCC-5-SPA_MDR_DONE

5-Notice

SPA[dec] completed Minimal Disruptive Restart

Informational message that the Minimal Disriptive Restart of a particular SPA has completed.

iosxe-chassismgr

Informational notification. No action is required.

CMCC-5-SPA_MDR_INIT

5-Notice

SPA[dec] initiated Minimal Disruptive Restart

Informational message that the Minimal Disriptive Restart of a particular SPA has begun.

iosxe-chassismgr

Informational notification. No action is required.

CMCC-6-FLOW_CONTROL_OTHER

6-Information

Flow control error seen, Cause [chars]

Flow control error is detected in the FPGA

iosxe-chassismgr

Appropriate action is taken in software to correct this error. If the problem persists, the MIP100 hardware may need to be replaced.

CMCC-6-FRU_HWPRG_UPG_ADM1266_CFG_SUCCESS

6-Information

Hardware programmable ADM1266 Configurations on [chars] in slot [chars] were successfully programmed.

The hw-programmable ADM1266 configuration was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_HWPRG_UPG_LMK03328_CFG_RESET

6-Information

Hardware programmable LMK03328 Configurations on [chars] in slot [chars] were successfully partially programmed, please reload it to continue programming.

The hw-programmable LMK03328 configuration was partially upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_HWPRG_UPG_LMK03328_CFG_SUCCESS

6-Information

Hardware programmable LMK03328 Configurations on [chars] in slot [chars] were successfully programmed.

The hw-programmable LMK03328 configuration was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_HWPRG_UPG_PSOC_PREPARE

6-Information

Hardware programmable PSOCs on [chars] in slot [chars] were set in the golden mode. The card will reload to finish the upgrading

The hw-programmable PSOCs were set in the golden mode for FPD

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_HWPRG_UPG_PSOC_START

6-Information

Hardware programmable PSOCs on [chars] in slot [chars] are upgrading, please don't reload or power-cycle this card. It will take about 2 mins to finish.

The hw-programmable PSOC is upgrading

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_HWPRG_UPG_PSOC_SUCCESS

6-Information

Hardware programmable PSOCs on [chars] in slot [chars] were successfully programmed. The card will reload to make new firmware work.

The hw-programmable PSOC was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_HWPRG_UPG_TPS40422_CFG_RESET

6-Information

Hardware programmable TPS40422 Configurations on [chars] in slot [chars] were successfully partially programmed, please reload it to continue programming.

The hw-programmable TPS40422 configuration was partially upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_HWPRG_UPG_TPS40422_CFG_SUCCESS

6-Information

Hardware programmable TPS40422 Configurations on [chars] in slot [chars] were successfully programmed.

The hw-programmable TPS40422 configuration was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_IOFPGA_UPG_START

6-Information

Field programmable device on [chars] in slot [dec] is being upgraded. It will take about 2 mins to finish the upgrade. Please do not reload or power-cycle this card while upgrade is in progress.

The field programmable device on the FRU is upgrading

iosxe-chassismgr

No action is required. This is informational message

CMCC-6-FRU_LC_UPGRADE_REQD

6-Information

Found mismatch between the Line card FPGA versions bundled in Software and programmed in Hardware in slot [dec]. FPGA version bundled in SW: %x, present in HW: %x. To upgrade the FPGA to version bundled in SW, perform physical OIR of the line card or run the CLI: hw-module subslot <slot>/<SPA no.> oir power-cycle

New FPGA is bundled in SW. FPGA upgrade is needed.

iosxe-chassismgr

To upgrade to latest FPGA, do physical OIR Line card or do Pseudo OIR of the line card using CLI: hw-module subslot <slot>/<SPA no.> oir power-cycle; To view the present FPGA versions in chassis, use the CLI: show firmware version all

CMCC-6-FRU_UPGRADE_REQD

6-Information

Slot [dec] needs firmware upgrade. Firmware upgrade is traffic impacting. To perform firmware upgrade use any of the 3 options: Option 1: Perform physical removal and insertion of the line card. Option 2: Run the <CLI> 'hw-module subslot [dec]/0 oir power-cycle' </CLI>. Option 3: Perform manual upgrade using <CLI> 'upgrade hw-programmable all filename bootflash: all' </CLI>. Use <CLI>'show firmware version all'</CLI> to know the mismatch

New version bundled in Software & Current Hardware running version is not latest. upgrade is needed. please follow the options provided

iosxe-chassismgr

To perform firmware upgrade use any of the 3 options: Option 1: Perform physical removal and insertion of the line card Option 2: Run the <CLI> 'hw-module subslot <slot>/0 oir power-cycle' </CLI> Option 3: Perform manual upgrade using <CLI> 'upgrade hw-programmable all filename bootflash: all' </CLI> Use <CLI>'show firmware version all'</CLI> to know the mismatch

CMCC-6-FRU_VER_MISMATCH

6-Information

[chars]: Found mismatch between the versions bundled in Software and programmed in Hardware in slot [dec]. Version Present in HW: %x, Version present in SW Bundle: %x.

New FW is bundled in SW. FW upgrade is needed.

iosxe-chassismgr

To perform firmware upgrade use any of the 3 options: Option 1: Perform physical removal and insertion of the line card Option 2: Run the <CLI> 'hw-module subslot <slot>/0 oir power-cycle' </CLI> Option 3: Perform manual upgrade using <CLI> 'upgrade hw-programmable all filename bootflash: all' </CLI> Use <CLI>'show firmware version all'</CLI> to know the mismatch

CMCC-6-LC_FPGA_UPGRADE_NOT_REQUIRED

6-Information

FPGA version on linecard in switch [dec] slot [dec] is 0x%x

Upgrade of FPGA on the linecard is not required.

iosxe-chassismgr

No action required.

CMCC-6-LC_FPGA_UPGRADE_PWR_CYCLE_DONE

6-Information

Power cycled the linecard in switch [dec] slot [dec], after FPGA upgrade.

Power cycled the linecard after FPGA upgrade.

iosxe-chassismgr

No action required.

CMCC-6-LC_FPGA_UPGRADE_START

6-Information

Linecard fpga device in switch [dec] slot [dec] is being upgraded. It will take about 5 mins to complete the upgrade Linecard will power-cycled automatically during this process. Please do not reload or power-cycle the linecard when upgrade is in progress

The fpga device on the linecard is upgrading

iosxe-chassismgr

No action required.

CMCC-6-LC_FPGA_UPGRADE_SUCCESS

6-Information

Successfully upgraded the field programmable device on linecard in switch [dec] slot [dec]. The line card will be power cycled

Upgrade field programmable device was successful on the given FRU. Linecard needs to be power-cycled or removed and re-inserted for upgrade to take effect.

iosxe-chassismgr

Line card needs to be power cycled or removed and re-inserted for the upgrade to take effect.

CMCC-6-MGMT_SFP_INSERT

6-Information

transceiver module inserted in [chars]

The online insertion and removal (OIR) facility detected a newly inserted transceiver module for the interface specified in the error message.

iosxe-chassismgr

No action required.

CMCC-6-MGMT_SFP_REMOVED

6-Information

Transceiver module removed from [chars]

The online insertion and removal (OIR) facility detected the removal of a transceiver module from the interface specified in the error message.

iosxe-chassismgr

No action required.

CMCC_LED-6-BEACON_LED_TURNED

6-Information

Slot [dec] Beacon LED turned [chars]

Beacon LED turned ON/OFF. This is a notification message only.No action is required.

iosxe-chassismgr

This is a notification message only. No action is required.

CMDMA-2-FPGA_DOWNLOAD_FAILED

2-Critical

Critical Error is detected while downloading the FPGA. After this card will reboot.

Due to timing issue in DMA sometime FPGA download failure is seen

iosxe-chassismgr

Contact your Cisco technical support representative and provide the system report and crash file.

CMDMA-6-FPGA_DOWNLOAD_INFO

6-Information

[chars] fpga DMA download [chars]

This is informative message about the start/complete of the fpga DMA download

iosxe-chassismgr

No action required

CMEM-3-SENSOR_INIT_FAILED

3-Error

Sensor ([chars]) initialization failed due to [chars].

This error indicates that environmental monitor software cannot initialize the sensor. The software will not register and monitor this sensor. This could occur when the IDPROM has a bad I2C address for this sensor.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

CMEM-4-OBFL_INIT_FAILED

4-Warning

OBFL initialization failed.

This error indicates the OBFL dedicated filesystem is not mounted. OBFL diagnostic information will not be retained for customer troubleshooting.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

CMFC-0-CHASFS_PROPERTY_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly created.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMFC-0-CHASFS_PROPERTY_SET

0-Emergency

Failed to write chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property failed to write.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMFC-3-IDPROM_ACCESS

3-Error

Failed to access or process IDPROM '[chars]': [chars]

Failed access or process an IDPROM. This could be due to a hardware defect, software defect or incorrect IDPROM content.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMFP-0-CPLD_INITIALIZATION

0-Emergency

CPLD initialization has failed because [chars]

The CPLD has failed to initialize. This could be due to a hardware or software driver defect.

iosxe-chassismgr

Examine the hardware and CPLD driver logs and see if the logs provide information about a correctable problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMFP-0-CPLD_IOCTL

0-Emergency

A CPLD driver I/O control has failed because [chars]

A complex programmable logic device (CPLD) I/O driver control has failed. This error could be caused by a hardware or software driver defect.

iosxe-chassismgr

Examine the logs for CPLD driver and hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information

CMFP-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMFP-0-SPI4_MUX_HALT

0-Emergency

SPI4 MUX driver has detected a critical error [chars]

A SPI4 MUX driver has failed or detected a critical hardware fault. This could be due to a hardware defect or driver defect.

iosxe-chassismgr

The only corrective action is to restart the FP

CMFP-2-BAD_ID_HW

2-Critical

Failed Identification Test in [chars]. The module [chars] may not be a genuine Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco memory, WIC cards, AIM cards, Network Modules, SPA cards, GBICs or other modules into a Cisco product is the cause of a support issue, Cisco may deny support under your warranty or under a Cisco support program.

Hardware in the specified location could not be identified as a genuine Cisco product

cbr-platform-infra

Replace the hardware with a genuine Cisco product. If this message recurs, contact your Cisco technical support representative and provide the representative with the gathered information.

CMFP-2-FPGA_DOWNLOAD_FAILED

2-Critical

Critical Error is detected while downloading the FPGA. After this card will reboot.

Due to timing issue in DMA sometime FPGA download failure is seen

iosxe-chassismgr

Contact your Cisco technical support representative and provide the system report and crash file.

CMFP-2-UADP_EVENT

2-Critical

UADP EVENT (ASIC #[dec] [chars])

Unified Access Datapath ASIC Event

iosxe-chassismgr

Copy the message exactly as it appears on the console or in the system log.

CMFP-3-CPLD_ECSR_ERROR

3-Error

An error has been detected on the ECSR bus

An error has been detected on the ECSR bus. This may cause problems when accessing the fowarding processor

iosxe-chassismgr

Some of these errors are catastrophic and others are not. If the FRU did not restart assume corrective action was taken. Please check the chassis-manager logs for errors.

CMFP-3-CPLD_ERP_ERROR

3-Error

An error has been detected on the ERP bus (cause [dec], phase [dec])

An error has been detected on the ERP bus. This may cause problems when accessing the fowarding processor

iosxe-chassismgr

Some of these errors are catastrophic and others are not. If the FRU did not restart assume corrective action was taken. Please check the chassis-manager logs for errors.

CMFP-3-DDR_SINGLE_BIT_ERROR

3-Error

Single-bit DRAM ECC error: mme: [dec], sbe: [dec], address: 0x%08X, pid: [dec], name: [chars]

A single-bit data corruption error has occurred in the forwarding processor (FP).

iosxe-chassismgr

These errors are self-correcting. If the problem persists, the FP hardware may need to be replaced.

CMFP-3-DPP_MAC_LINK_ERROR

3-Error

DPP Mac Link failed [chars]

One or more Mac links of DPP blocks failed. It could be because of a configuration error or hardware failure.

iosxe-chassismgr

Note the time of the error message and examine show hardware platform cman fp for detailed Report.

CMFP-3-DPP_SERDES_SYNC_ERROR

3-Error

UADP fabric interface synchronisation [chars]

One of more UADP fabric interface Serdes failed to sync, This could be due to a hardware defect.

iosxe-chassismgr

No action is required.

CMFP-3-FPGA_IMG_ABSENT

3-Error

FPGA image is absent please contact Cisco technical support representative.

Due to corruption is file system FPGA images are deleted.

iosxe-chassismgr

Contact your Cisco technical support representative and provide the tracelogs.

CMFP-3-HB_TIMEOUT

3-Error

Periodic Heartbeat message from RP timed out.

RP sends periodic heartbeat message to the ESP. The ESP did not receive this heartbeat message for last timeout period.

iosxe-chassismgr

Examine the system logs for errors.

CMFP-3-HT_FATAL_ERROR

3-Error

Failed to initialize the HyperTransport interface to the QFP

The HyperTransport interface to the QFP failed to initialize completely. Software will restart the ESP to recover

iosxe-chassismgr

No action is required.

CMFP-3-IDPROM_ACCESS

3-Error

Failed access or process an IDPROM because [chars]

Access to an IDPROM failed due to a hardware or software defect, or incorrect IDPROM content.

iosxe-chassismgr

Examine the system logs for IDPROM and hardware errors. Copy the error message and related information exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered nformation.

CMFP-3-IDPROM_SENSOR

3-Error

One or more sensor fields from the idprom failed to parse properly because [chars].

Output from the IDPROM sensors failed to parse, commonly caused by a checksum failure in the IDPROM.

iosxe-chassismgr

Examine the system logs for IDPROM and hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

CMFP-3-MASTERSHIP_UPDATE

3-Error

An error ([chars]) has occurred while communicating the mastership role of this FP to the CPP. The FP is currently [chars]

An error occurred while communicating a change in the state (Active, Active with a Standby, or Standby) of the forwarding processor (FP). The error can cause an inconsistency of expected states between FPs and could affect the replication of state between the FPs.

iosxe-chassismgr

Examine the system logs for errors. This error is usually temporary.

CMFP-3-MASTERSHIP_WATCH

3-Error

Failed to initialize a watch on the active rp because [chars]

The fp process has failed to setup a watch on the rp chasfs active-rp property. This error is likely caused by a problem with chasfs as a whole.

iosxe-chassismgr

Examine the logs to determine the exact reason for the failure.

CMFP-3-N2_DDR_MBE

3-Error

The encryption processor has detected an uncorrectable multi-bit error in memory at address [dec]

The encryption processor has detected an uncorrectable multi-bit in memory. This could be due to a hardware defect.

iosxe-chassismgr

Examine the logs for encryption processor hardware errors.

CMFP-3-N2_FATAL_ERROR

3-Error

An error has been detected on encryption processor: type [chars]

An error has been detected on encryption processor.

iosxe-chassismgr

Please check the chassis-manager logs for errors.

CMFP-3-N2_INPUT_EXCEPT

3-Error

Crypto device overloaded. : type [chars]: 0x%08X

An exception has been detected on encryption processor.

iosxe-chassismgr

Please lower crypto traffic rate. If the error still happens, encryption processor may stop processing. Need to reload ESP.

CMFP-3-OCT_DRV_ERROR

3-Error

An error has been detected on encryption processor: [chars]: [chars]

An error has been detected on encryption processor.

iosxe-chassismgr

Please check the chassis-manager logs for errors.

CMFP-3-SBUS_FATAL_ERROR

3-Error

SBUS Controller not responding, bringing down [chars]

Spico SBUS controller fails to repsond, This could be due to a hardware defect. Reset the CHIP

iosxe-chassismgr

No action is required.

CMFP-3-SIF_SERDES_SYNC_ERROR

3-Error

Sif Serdes Sync Failed for Supervisor Failure Bitmap 0x%x

One of more Supervisor ASIC Sif Serdes failed to sync, This could be due to a hardeware defect.

iosxe-chassismgr

Note the time of the error message and examine the show hardware platform cman fp for detailed Sif Serdes Report.

CMFP-3-SPI4_MUX_STATUS

3-Error

SPI4 MUX driver has detected a informational error [chars] (occurred [dec] time(s))

A SPI4 MUX driver has failed or detected a information hardware fault. This could be due to a hardware defect or driver defect.

iosxe-chassismgr

Examine the logs for SPI4 MUX and hardware errors.

CMFP-3-STANDBY_EOBC_LINK_ERROR

3-Error

Standby EOBC link error detected.

Standby EOBC link error: either link state is down, or duplexity is not full, or speed is not 1Gbps.

iosxe-chassismgr

Examine the system hardware. Re-seat and securely screw in all FRUs. If the problem persists, please contact TAC support.

CMFP-6-CRYPTO_MODULE

6-Information

Crypto Hardware Module is [chars]

The log is to indicate whether Crypto Hardware Module IPSECHW is physically inserted in the chassis.

iosxe-chassismgr

No action is required.

CMFP-6-DPP_SERDES_SYNC

6-Information

UADP fabric interface synchronisation [chars]

The log is to indicate UADP fabric interface Serdes Sync succeeded during intialization of setup.

iosxe-chassismgr

No action is required.

CMFP-6-N2_DRV_UPDATE

6-Information

Hardware crypto device disabled. [chars]: [chars]

A crypto device driver has failed or detected a hardware fault. This could be due to a hardware defect or driver defect.

iosxe-chassismgr

The only corrective action is to restart the ESP

CMLIB-2-IDPROM_INVALID

2-Critical

Invalid IDPROM assembly number 0x%04X. IDPROM update required

IDPROM assembly number is not supported.

iosxe-chassismgr

IDPROM update is required

CMLIB-3-THROUGHPUT_VALUE_APPLY_FAILED

3-Error

Throughput [chars] [chars] - failed to persist throughput of [chars] kbps. Error: [chars]

Status indicating that a failure was observed during the writing of the throughput to persistent store. The error reason may shed light on the cause. The throughput value may have be used to configure the CPP hardware.

iosxe-csl

Examine the ios, chassis-manager and license-manager logs for possible clues.

CMLIB-3-THROUGHPUT_VALUE_SETUP_FAILED

3-Error

Throughput [chars] [chars], throughput set to [chars] kbps. Error: [chars]

Status indicating that a failure was observed during the setup of the throughput. The error reason may shed light on the cause. The set value is used to configure the CPP hardware.

iosxe-csl

Examine the ios, chassis-manager and license-manager logs for possible clues.

CMLIB-4-FW_CHECK

4-Warning

slot [chars]: [chars] current firmware version is [chars], while the minimum required version is [chars]. Please upgrade it to minimum required version or higher.

Firmware version in the specified location is lower than minimum required version

iosxe-chassismgr

Upgrade firmware version to latest.

CMLIB-6-THROUGHPUT_VALUE

6-Information

Throughput [chars] [chars], throughput set to [chars] kbps

Status indicating whether appropriate throughput is found or enabled and ensuring the value is used to configure the CPP hardware.

iosxe-csl

No user action is necessary. This is an informational message indicating that the throughput is configured.

CMRP-0-CHASFS_LOCATION_TRANSLATE

0-Emergency

Failed to translate a location to a chasfs object name because [chars]

The chassis manager failed to translate a location to a chasfs object name.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASFS_OBJECT_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] because [chars]

The hardware failed to create a chassis filesystem object.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASFS_OBJECT_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] not present.

A chassis filesystem object expected to be present is not. This could be due to a software defect or filesystem failure.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASFS_OBJECT_WATCH

0-Emergency

Failed to watch chassis filesystem object [chars] because [chars]

A chassis filesystem object was not watched because of the reason stated in the error message.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASFS_PROPERTY_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly created.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASFS_PROPERTY_GET

0-Emergency

Failed to read chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly read by the system.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASFS_PROPERTY_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] property [chars] not present.

A chassis filesystem object property expected to be present is not. This could be due to a software defect or filesystem failure.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASFS_PROPERTY_SET

0-Emergency

Failed to write chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property failed to write.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASSIS_ID

0-Emergency

Error while updating chassis id, Error: [chars]

The chassis Id is invalid. This could be due to a hardware defect, software defect or incorrect IDPROM content.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASSIS_STATUS

0-Emergency

Failed to get chassis hardware status because [chars]

The system failed to get the chassis hardware status.

iosxe-chassismgr

Note the time of the error message and examine the logs for CPLD driver or hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CHASSIS_TYPE

0-Emergency

The chassis type [chars] is invalid.

The chassis type is invalid. This could be due to a hardware defect, software defect or incorrect IDPROM content.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CLOCK_MASTERSHIP_SET

0-Emergency

Failed to set CLOCK mastership because [chars]

The router failed to establish CLOCK mastership.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CPLD_INITIALIZATION

0-Emergency

The RP CPLD has failed initialization because [chars]

The RP CPLD has failed to initialize. This could be due to a hardware or software driver defect.

iosxe-chassismgr

Examine the hardware and CPLD driver logs and see if the logs provide information about a correctable problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-CPLD_IOCTL

0-Emergency

A CPLD driver I/O control has failed because [chars]

A CPLD driver I/O control has failed. This could be due to a hardware or software driver defect.

iosxe-chassismgr

Examine the hardware and CPLD driver logs and see if the logs provide information about a correctable problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-DDR_INITIALIZATION

0-Emergency

The RP DDR has failed initialization because [chars]

The RP DDR has failed to initialize. This could be due to a hardware or software driver defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for DDR or hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-EHSA_INITIALIZATION

0-Emergency

EHSA initialization has failed because [chars]

EHSA has failed initialization. This could be due to a hardware or software defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for EHSA and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-EHSA_STATE_GET

0-Emergency

Failed to get EHSA state because [chars]

Failed to get EHSA state. This could be due to a hardware or software defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for EHSA and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-EHSA_STATE_SET

0-Emergency

Failed to set EHSA state because [chars]

Failed to set EHSA state. This could be due to a hardware or software defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for EHSA and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-FP_MASTERSHIP_SET

0-Emergency

Failed to set FP mastership because [chars]

The router failed to establish ESP mastership.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-HT_INITIALIZATION

0-Emergency

The RP HyperTransport has failed initialization because [chars]

The RP HyperTransport has failed initialization. This could be due to a hardware defect or HT driver defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for HT driver and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-HT_IOCTL

0-Emergency

A RP HyperTransport driver I/O control has failed because [chars]

A RP HyperTransport driver I/O has failed. This could be due to a hardware defect or HT driver defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for HT driver and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-I2C_INITIALIZATION

0-Emergency

The RP I2C has failed initialization because [chars]

The RP I2C has failed to initialize. These components provide low-level communications between the RP and the other cards in the system.

iosxe-chassismgr

Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-INTERNALS_INITIALIZATION

0-Emergency

Failed to initialize internal state because [chars]

The system failed to initilize the internal state for the reason mentioned in the error message.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-INTERNAL_HW_SHUTDOWN

0-Emergency

Internal unrecoverable error condition was detected. System is being reset.

Internal unrecoverable error condition was detected, and so the system was reset. If this error condition reoccurs, the hardware may need to be replaced.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-0-INVALID_ARGUMENT

0-Emergency

A system function was given an invalid argument.

A system function was given an invalid argument. This is due to a software defect.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-IPC_CONNECTION_INVALID

0-Emergency

An IPC connection has invalid state.

An IPC connection has an invalid state. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-IPC_CONNECT_MASTER

0-Emergency

IPC connection to the active RP failed because [chars]

IPC connection to the active RP failed. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-IPC_CONNECT_REMOTE_IOS

0-Emergency

IPC connection to a remote IOSd failed because [chars]

IPC connection to a remote IOSd failed. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-IPC_INITIALIZATION

0-Emergency

IPC initialization failed because [chars]

IPC initialization failed. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-MESSAGE_REGISTER

0-Emergency

Failed to register with active RP because [chars]

The active RP failed to register.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-MESSAGE_RELAY

0-Emergency

Failed to relay a message because [chars]

Failed to relay a message. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-MESSAGE_RESPONSE

0-Emergency

An invalid message response was received because [chars]

An invalid message response was received. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-MQIPC_ADVANCE

0-Emergency

Failed to advance MQIPC queue because [chars]

The MQIPC initialization failed.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-MQIPC_INITIALIZATION

0-Emergency

MQIPC initialization failed because [chars]

MQIPC initialization failed. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-PEER_TABLE

0-Emergency

A peer table initialization or maintenance function failed because [chars]

A peer table initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-PLATFORM_FAMILY_TYPE

0-Emergency

The platform family type [chars] is invalid.

The platform family type is invalid. This could be due to a hardware defect, software defect or incorrect IDPROM content.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-PWR_FAULT_INITIALIZATION

0-Emergency

Power fault monitor initialization has failed because [chars]

The power fault monitor has failed to initialize.

iosxe-chassismgr

Note the time of the error message and examine the Chassis Manager logs. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-RESOLVE_FRU

0-Emergency

Failed to determine [chars] card because [chars]

The router failed to determine a FRU state.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-RESOURSE

0-Emergency

Resource allocation failed in [chars] because [chars]

The system is unable to allocate the requested resource.

iosxe-chassismgr

In most cases, this message is seen as a result of a temporary resource issue. Retry the request for the resource when the system is experiencing lower traffic volumes. If the message persists, reload the router using the reload command.

CMRP-0-ROLE_ADDRESS_UPDATE

0-Emergency

Failed to update role-based EOBC IP addresses because [chars].

The system failed to update a role-based EOBC IP address for the reason stated in the message line.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-SERDES_INITIALIZATION

0-Emergency

The RP Serial Bridge ASIC has failed initialization because [chars]

The RP Serial Bridge ASIC has failed to initialize. This could be due to a hardware defect, software driver defect or improper internal configuration.

iosxe-chassismgr

Note the time of the error message and examine the logs for Serial Bridge ASIC and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-SERDES_INTERRUPT_DISPATCH

0-Emergency

Serial Bridge interrupt dispatch error: [chars]

Failed to dispatch an error interrupt from the Serial Bridge. This could be due to a software defect or inconsistent internal state.

iosxe-chassismgr

Note the time of the error message and examine the logs for Serial Bridge errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-SERDES_IOCTL

0-Emergency

A Serial Bridge driver I/O control has failed because [chars]

A Serial Bridge driver I/O control has failed. This could be due to a hardware or software driver defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for Serial Bridge driver or hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-SERVICES_INITIALIZATION

0-Emergency

Failed to initialize general application services because [chars]

The system failed to initialize application services.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-SIGNAL_INITIALIZATION

0-Emergency

Failed to initialize signals because [chars]

The system failed to initialize signals.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-SLOTS_INITIALIZATION

0-Emergency

Failed to initialize chassis slot information because [chars]

The system failed to initialize the chassis slot information.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM or software errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-SLOT_INVALID

0-Emergency

A card absolute slot number cannot be determined for this chassis type

An absolute slot number is invalid. This could be due to a software defect or incorrect IDPROM content.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM or software errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-SYSPAGE_WRITE_ERROR

0-Emergency

The syspage chassis-type write has failed because [chars]

The syapge chassis-type write failed. This could be due to a software defect.

iosxe-chassismgr

Note the time of the error message and examine the Chassis Manager logs. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-UIPEER_CREATE

0-Emergency

Failed to create user interface peer.

The system failed to create a user interface peer.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-0-WANPLL_INITIALIZATION

0-Emergency

The RP WAN PLL has failed initialization because [chars]

The RP WAN PLL has failed to initialize. This could be due to a hardware or software driver defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for WAN PLL or hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-2-ACT2_UDI_DATA_INVALID

2-Critical

The act2 udi secure area format mismatch with unsecure area

This Router may not have been manufactured by Cisco or with Cisco's authorization. This product may contain software that was copied in violation of Cisco's license terms. If your use of this product is the cause of a support issue, Cisco may deny operation of the product, support under your warranty or under a Cisco technical support program such as Smartnet. Please contact Cisco's Technical Assistance Center for more information.

cbr-platform-infra

Replace the current product with a Cisco authorised product. If this message recurs, contact your Cisco technical support representative and provide the representative with the gathered information.

CMRP-2-BAD_ID_HW

2-Critical

Failed Identification Test in [chars]. The module [chars] may not be a genuine Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco memory, WIC cards, AIM cards, Network Modules, SPA cards, GBICs or other modules into a Cisco product is the cause of a support issue, Cisco may deny support under your warranty or under a Cisco support program.

Hardware in the specified location could not be identified as a genuine Cisco product

cbr-platform-infra

Replace the hardware with a genuine Cisco product. If this message recurs, contact your Cisco technical support representative and provide the representative with the gathered information.

CMRP-2-CRYPTOGRAPHIC_HW_MISMATCH

2-Critical

ESP[dec] does not support strong cryptography. Chassis will reload.

IOS software featuring strong cryptography is invalid for use with any non-strong-cryptography Embedded Service Processor. The router node will reload if this combination is encountered.

iosxe-chassismgr

Install a non-strong-cryptography image of the RP IOS package or replace the indicated Embedded Service Processor with one that supports strong-cryptography

CMRP-2-FRU_CPLD_INCOMPATIBLE

2-Critical

[chars] in slot [chars] has been held in reset as its CPLD firmware version is incompatible with [chars]

This FRU requires a newer CPLD firmware to function properly in this chassis

iosxe-chassismgr

Upgrade the CPLD firmware on this FRU using the <b> upgrade hw-programmable CPLD file <pkg_file> slot <fru_slot> </b> command. Please see http://www.cisco.com/en/US/docs/routers /asr1000/cpld/hw_fp_upgrade.html for more details.

CMRP-2-FRU_FPGA_INCOMPATIBLE

2-Critical

[chars] in slot [chars] has been held in reset as its FPGA firmware version is incompatible with [chars]

This FRU requires a newer FPGA firmware to function properly in this chassis

iosxe-chassismgr

Upgrade the FPGA firmware on this FRU using the <b> upgrade hw-programmable FPGA file <pkg_file> slot <fru_slot> </b> command.

CMRP-2-FRU_HWPRG_UPG_FAILED

2-Critical

Failed to [chars] [chars] hardware programmable on [chars] in [chars].

Upgrade hw-programmable failed to upgrade the CPLD/FPGA firmware on the given FRU

iosxe-chassismgr

Reload the card and retry to program the hw-programmable. If the card fails to come up please contact TAC

CMRP-2-FRU_HWPRG_UPG_PSOC_PREPARE

2-Critical

Hardware programmable PSOCs on [chars] in slot [chars] were set in the golden mode. Please power-cycle or OIR the card to finish the upgrading

The hw-programmable PSOCs were set in the golden mode for FPD

iosxe-chassismgr

No action is required. This is informational message

CMRP-2-FRU_HWPRG_UPG_PSOC_START

2-Critical

Hardware programmable PSOCs on [chars] in slot [chars] are upgrading, please don't reload or power-cycle this card. It will take about 10 mins to finish.

The hw-programmable PSOC is upgrading

iosxe-chassismgr

No action is required. This is informational message

CMRP-2-FRU_HWPRG_UPG_PSOC_SUCCESS

2-Critical

Hardware programmable PSOCs on [chars] in slot [chars] were successfully programmed. Please power-cycle or OIR the card to make them work

The hw-programmable PSOC was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMRP-2-QUAD_SUP_DISABLE_SUPERVISOR

2-Critical

Exceeded the maximum failure attempts to enable Quad-Sup SVL. Forcing the supervisor in Switch [dec] slot [dec] into reset state. Keeping the supervisor in this state may cause system instability. Please pull out the supervisor and follow the quad sup migration procedure.

ICS is booted with quad sup incompatible image

iosxe-chassismgr

Boot the supervisor in quad sup compatible image

CMRP-2-QUAD_SUP_INCOMPATIBLE_SUPERVISOR_PWR_OFF

2-Critical

Exceeded the maximum failure attempts to enable Quad-Sup SVL. Forcing the supervisor in Switch [dec] slot [dec] into power off state. Keeping the supervisor in this state may cause system instability. Please pull out the supervisor, use 'hw-module switch <switch-num> subslot <slot> oir power-cycle' to power it on back and follow the quad sup migration procedure.

ICS is booted with quad sup incompatible image

iosxe-chassismgr

Boot the supervisor in quad sup compatible image

CMRP-2-QUAD_SUP_SW_MISMATCH

2-Critical

The Peer supervisor in Switch [dec] Slot [dec] is not reachable, one of the reason could be, Supervisor booting with quad-sup incompatible image. Continuing in this state could lead to undesirable behaviour. To recover from this state, boot the supervisor in Quad-SUP compatible image by following the migration procedure.(Attempt : [dec] of 5)

ICS is booted with quad sup incompatible image

iosxe-chassismgr

Boot the supervisor in quad sup compatible image or contact TAC

CMRP-2-QUAD_SUP_UPLINK_SVL_SUPERVISOR_PWR_OFF

2-Critical

Supervisor in Switch [dec] Slot [dec] is booted when stackwise-virtual configured over supervisor ports which is unsupported. Keeping the supervisor in this state may cause system instability. Forcing the supervisor into power off state. Please pull out the supervisor, use 'hw-module switch <switch-num> subslot <slot> oir power-cycle' to power it on back and follow the quad sup migration procedure.

ICS is booted with quad sup with stackwise-virtual over supervisor ports

iosxe-chassismgr

Boot the supervisor with stackwise-virtual configured over linecard ports

CMRP-2-RP_CPLD_INCOMPATIBLE

2-Critical

All other cards in the system have been held in reset as the Active RP [chars] in slot [chars] has CPLD firmware version that is incompatible with [chars]

Active RP requires a newer CPLD firmware to function properly in this chassis

iosxe-chassismgr

Upgrade the CPLD firmware on this FRU using the <b> upgrade hw-programmable CPLD file <pkg_file> slot <fru_slot> </b> command. Please see http://www.cisco.com/en/US/docs/routers /asr1000/cpld/hw_fp_upgrade.html for more details.

CMRP-2-RP_CPLD_INCOMPATIBLE_OTHER

2-Critical

[chars] in slot [chars] has been held in reset because [chars]

Active RP requires a newer CPLD firmware to function properly in this chassis.

iosxe-chassismgr

Upgrade the CPLD firmware on this FRU using the <b> upgrade hw-programmable CPLD file <pkg_file> slot <fru_slot> </b> command. Please see http://www.cisco.com/en/US/docs/routers /asr1000/cpld/hw_fp_upgrade.html for more details.

CMRP-3-BITS_INITIALIZATION

3-Error

The RP BITS E1/T1 interface has failed initialization because [chars]

The RP BITS E1/T1 interface has failed to initialize. This could be due to a hardware defect, a software driver defect or improper configuration.

iosxe-chassismgr

Note the time of the error message and examine the logs for BITS driver or hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative

CMRP-3-CHASFS_OBJECT_DESTROY

3-Error

Failed to destroy chassis filesystem object [chars] because [chars]

A chassis filesystem object that should have been destroyed was not destroyed.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-CHASFS_PROPERTY_DESTROY

3-Error

Failed to destroy chassis filesystem proprty [chars]/[chars] because [chars]

A chassis filesystem property that should have been destroyed was not destroyed.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-CHASSIS_FRU_FAULT_IGNORED

3-Error

CMAN_IGNORE_FRU_FAULTS is set. [chars]: [chars]

Debug variable will prevent a FRU from being restarted due to some faults.

iosxe-chassismgr

No action is necessary.

CMRP-3-CHASSIS_FRU_FAULT_IGNORED_ISSET

3-Error

CMAN_IGNORE_FRU_FAULTS is set. Some FRU faults will be ignored and FRU may not restart due to a fault

Debug variable will prevent a FRU from being restarted due to some faults.

iosxe-chassismgr

No action is necessary.

CMRP-3-CHASSIS_MONITOR_FRU_BOOT_RETRIES_EXCEEDED

3-Error

[chars] has been held in reset because it has failed to successfully boot in [dec] tries

The FRU has failed to successfully boot in the maximum allowable attempts and is held in reset.

iosxe-chassismgr

Remove the FRU from the chassis if the FRU continously fails to boot.

CMRP-3-CHASSIS_MONITOR_FRU_BOOT_STATUS

3-Error

Reloading [chars] because the FRU boot status is unknown

The time at which the FRU started booing is not available. This time is used to check the boot status of the FRU.

iosxe-chassismgr

Remove the FRU from the chassis if the FRU is continously reloaded.

CMRP-3-CHASSIS_MONITOR_ONLINE_TIME_EXCEEDED

3-Error

Reloading [chars] because it has failed to come online

A FRU has failed to come online within the maximum boot time.

iosxe-chassismgr

Remove the FRU from the chassis if the FRU is continously reloaded.

CMRP-3-CHASSIS_MONITOR_ONLINE_TIME_IGNORED

3-Error

[chars] exceeded online time but will not be reset because fault ignore is configured

The FRU failed to come online within the maximum online time. This message applies to all FRUs. A reload will not be performed because fault ignore is configured.

iosxe-chassismgr

No action is necessary.

CMRP-3-CHASSIS_MONITOR_READY_TIME_EXCEEDED

3-Error

Reloading [chars] because it has failed to become ready for packet processing

The FRU failed to become ready within the maximum ready time. This message applies to FP FRUs. A switchover will be performed if another FP is available.

iosxe-chassismgr

Remove the FRU from the chassis if the FRU is continously reloaded.

CMRP-3-CHASSIS_MONITOR_READY_TIME_IGNORED

3-Error

[chars] exceeded ready time but will not be reset because fault ignore is configured

The FRU failed to become ready within the maximum ready time. This message applies to FP FRUs. A switchover and/or reload will not be performed because fault ignore is configured.

iosxe-chassismgr

No action is necessary.

CMRP-3-DDR_SINGLE_BIT_ERROR

3-Error

Single-bit DRAM ECC error: mme: [dec], sbe: [dec], address: 0x%08X, pid: [dec], name: [chars]

The RP DRAM has single-bit ECC errors.

iosxe-chassismgr

In most cases, the system self-corrects these single-bit ECC errors and no user action is necessary. If the problem persists, gather the console output with the error message along with the show tech-support command output and provide the gathered information to a Cisco technical support representative.

CMRP-3-DUAL_IOS_STANDBY_BAY

3-Error

Standby bay cannot be launched due to failure in bringing down existing processes (Attempts: [dec])

During standby bay shutdown, some related processes still remain running for an unexpectedly prolonged period of time. Chassis-manager has timed-out waiting for all related processes to shutdown. As a result, it is unable to notify Process-manager to restart the bay

iosxe-chassismgr

Examine the logs for standby bay's Forwarding-manager (fman), Interface-manager (iman), Pluggable-Service-Daemon (psd) and IOS. Ascertain which of these processes is taking too long to shutdown and note the reason. Take corrective action based on the error noted in the log

CMRP-3-EXT_ALARM_INTERRUPT

3-Error

Alarm [chars]:external alarm contact [dec]

There is an external alarm on the line.

iosxe-chassismgr

If alarm is asserted, then clear at the source.

CMRP-3-FAN_FAILURE_SYS_SHUTDOWN

3-Error

WARNING: More than one Fan Failure detected and shutdown SYS state. System shutdown now TRUE:%x.

More than one fan failures are identified this causing overheating the system and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-3-FAN_INCOMPATIBLE

3-Error

The combination of Power Supply and Fan Tray is incompatible

The combination of Fan tray and one of the power supply slots is not supported. This could cause unpredictable system behavior.

iosxe-chassismgr

This error indicates that the combination of one of the power supplies in P0 or P1 is not supported with the Fan Tray. In order to fix this issue, please review the installation guide, replace the fan tray or the power supply based on the requirement. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-FAN_INITIALIZATION

3-Error

The RP has failed to initialize Fan [dec] module controller because [chars]

The RP failed to initialize the Fan. This could be due to a software defect.

iosxe-chassismgr

Note the time of the error message and examine the logs. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-FAN_REMOVE_IM_SHUT

3-Error

The Interface Modules (IM's) may shutdown in [dec] minutes [dec] seconds.

Fan tray has been removed and the router will shutdown to protect itself from overheating in the amount of time stated in the error message.

iosxe-chassismgr

Reinsert a fan tray into the fan tray slot as soon as possible.

CMRP-3-FAN_REMOVE_RSP2_SHUT

3-Error

The system will shut down when CYLON temp reaches 105C

Fan tray has been removed and the router will shutdown when cylon temperature reaches critical temperature i.e. 105C to protect itself from overheating in the amount of time stated in the error message.

iosxe-chassismgr

Reinsert a fan tray into the fan tray slot as soon as possible.

CMRP-3-FAN_REMOVE_RSP3_SHUT

3-Error

System received fan tray removal notification, Reinsert or service the faulty fan tray to avoid system shutdown due to high temperature. System will shutdown when the ARAD temp reaches Critical temperature i.e 105C. Based on current ARAD temperature [dec]C approximate time of shutdown is [dec] minutes [dec] seconds.

Fan tray has been removed and the router will shutdown when the ARAD temp reaches Critical temperature i.e 105C to protect itself from overheating.

asr903-system

Reinsert a fan tray into the fan tray slot as soon as possible.

CMRP-3-FAN_REMOVE_SHUT

3-Error

The system will shut down in [dec] minutes [dec] seconds

Fan tray has been removed and the router will shutdown to protect itself from overheating in the amount of time stated in the error message.

iosxe-chassismgr

Reinsert a fan tray into the fan tray slot as soon as possible.

CMRP-3-FAN_REMOVE_SYS_SHUTDOWN_PENDING

3-Error

System shutdown will occur in [dec] minutes.

The FRU is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-3-FP_DOWNREV

3-Error

[chars] has been held in reset because it is down-rev to the previous FP (0x%x -> 0x%x) in the chassis. Reboot the router to bring it up.

The FP inserted is a lower version than the previous Active FP in the router. Downrev of FP is not supported.

iosxe-chassismgr

Reboot the router.

CMRP-3-FP_LESSTHAN

3-Error

[chars] has been held in reset because it is down-rev to the active and cannot act as a standby.

The part number read from the FP IDPROM is not compatible with part number of the active FP; therefore, it may not act as a standby.

iosxe-chassismgr

Remove the FP from the chassis.

CMRP-3-FP_UNSUPP_UPREV

3-Error

[chars] has been held in reset because of an upsupported upgrade of FP (0x%x -> 0x%x) in the chassis. Reboot the router to bring it up.

The FP inserted is a higher version than the previous Active FP in the router but this upgrade of FP is not supported.

iosxe-chassismgr

Reboot the router.

CMRP-3-FRU_HWPRG_BAD_DEVICE

3-Error

Invalid HW programming device for [chars] in slot [chars].

The device is not supported in hardware programming.

iosxe-chassismgr

No action is required. This is an informational message

CMRP-3-FRU_HWPRG_LOAD_KMODULE_FAIL

3-Error

Cannot load a kernel module on [chars] in slot [chars].

Cannot load a Kernel module when upgrade CPLD or FPGA.

iosxe-chassismgr

Reload the card and retry to program the hw-programmable. If you get the same error, please contact TAC

CMRP-3-FRU_HWPRG_NO_FILE_ENTRY

3-Error

Cannot find file or directory on [chars] in slot [chars].

Cannot find a file or a directory when upgrade CPLD or FPGA.

iosxe-chassismgr

No action is required. This is an informational message

CMRP-3-FRU_HWPRG_RESTART_ERROR

3-Error

Error [chars] when Chassis Manager restarts [chars] in slot [chars].

Restart procedure has an error after upgrade.

iosxe-chassismgr

Try hw-module command to reload the FRU.

CMRP-3-FRU_HWPRG_UPG_PS_FAILED

3-Error

Power-Supply Module MCU [chars] in slot [chars] program failed

The hw-programmable power-supply upgrade failed

iosxe-chassismgr

Please check Power-Supply model and PKG file.

CMRP-3-FRU_HWPRG_UPG_SUCCESS

3-Error

Hardware programmable [chars] on [chars] in slot [chars] was successfully programmed. The card will now be power-cycled or reset.

The hw-programmable CPLD/FPGA was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMRP-3-FRU_HWPRG_UPG_UNSUPP

3-Error

Upgrade of hardware programmable [chars] on [chars] in slot [chars] is not supported. Card will now be powered down.

upgrade of hw-programmable CPLD/FPGA not supported.

iosxe-chassismgr

No action is required. This is informational message

CMRP-3-FRU_INCOMPATIBLE

3-Error

[chars] has been held in reset: [chars] is incompatible with [chars]

The part number read from the FRU IDPROM is invalid for this chassis type.

iosxe-chassismgr

Remove the FRU from the chassis.

CMRP-3-FRU_INVPARTNUM

3-Error

[chars] has been held in reset because the part number %08X is invalid.

The FRU IDPROM contains an invalid part number.

iosxe-chassismgr

The FRU IDPROM should be repaired or the board replaced.

CMRP-3-FRU_NOPARTNUM

3-Error

Cannot get part number from IDPROM for [chars]: [chars].

The FRU IDPROM cannot be read or does not contain a valid part number field.

iosxe-chassismgr

The FRU IDPROM should be repaired.

CMRP-3-HWLIB_INITIALIZATION

3-Error

The hardware library has failed to initialize because [chars]

This could be due to a hardware defect, software driver defect or improper internal configuration.

iosxe-chassismgr

Note the time of the error message and examine the logs for CPLD hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-HWMOD_FAIL

3-Error

hw-module [chars] command for slot [chars] failed ([chars])

The last hw-module command that was entered failed to complete

iosxe-chassismgr

Retry the command. If the retry of the command fails, reload the router. If reloading the router fails to resolve the problem, note the time of the error message and examine the Chassis Manager logs. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-HWPRG_UPG_UNSUPP_SLOT

3-Error

upgrade of hardware programmables on [chars] is not supported while in slot [chars]. Card will now be powered down.

upgrade of hw-programmable CPLD/FPGA not supported in the given slot. Move the card to a different slot and perform the upgrade

iosxe-chassismgr

Move the card to a different slot and perform the upgrade

CMRP-3-I2C_READ

3-Error

An I2C read has failed because [chars]

An I2C read has failed. This could be due to a hardware or software defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-I2C_WRITE

3-Error

An I2C write has failed because [chars]

An I2C write has failed. This could be due to a hardware or software defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-IDPROM_ACCESS

3-Error

Failed to access or process IDPROM '[chars]': [chars]

Failed access or process an IDPROM. This could be due to a hardware defect, software defect or incorrect IDPROM content.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-IDPROM_SENSOR

3-Error

One or more sensor fields from the idprom failed to parse properly because [chars].

One or more sensor fields from the IDPROM failed to parse properly. This problem is often the result of a checksum failure in the IDPROM.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-INCOMPATIBLE_FRU

3-Error

[chars] in slot [chars] is not compatible with [chars] and so it is disabled

The Product ID read from the FRU IDPROM is invalid for this hardware configuration.

iosxe-chassismgr

Remove the FRU from the chassis. Review the Hardware and Software Compatibility Matrix in IOS XE release notes to determine currently supported configurations.

CMRP-3-INCOMPATIBLE_FRU_SDWAN

3-Error

[chars] in slot [chars] is not supported in controller mode

Product ID read from FRU IDPROM is not supported in sdwan controller mode.

iosxe-chassismgr

Remove the FRU from the chassis

CMRP-3-INCOMPATIBLE_STANDBY_SUPERVISOR

3-Error

Standby supervisor is not compatible with the Active supervisor. Standby Supervisor will be disabled

Supervisor found in Standby slot may not be fully compatible with the active supervisor and may cause issues.

iosxe-chassismgr

Use supervisors with the same specifications to enable High Availablitly features.

CMRP-3-INTERNAL_HW_ERROR

3-Error

An nternal error condition was detected and resolved.

An internal error condition was detected, and affected part of hardware was reset. If this error condition reoccurs, the hardware may need to be replaced.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-3-INVENTORY_INITIALIZATION

3-Error

[chars] inventory file could not be read. FRU may need a reload to initialize properly, [chars]

The FRU inventory file could not be read. The file can possibly be corrupt. The FRU will possibly not initialize properly. The FRU should reset automatically. If it does not, it should be reloaded manually. If the error persists, the FRU will need to be replaced.

iosxe-chassismgr

Wait a few minutes. If FRU does not reset automatically, it should be manually reloaded. If error persists, the FRU needs to be replaced.

CMRP-3-LICENSE_TIMEOUT

3-Error

Throughput license request timed out. Throughput level set to default

Throughput license was never received from lman

iosxe-chassismgr

Examine logs for error messages

CMRP-3-OOD_OPR

3-Error

An OOD operation has failed because [chars]

An OOD opearion has failed. This could be due to a hardware or software defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for OOD errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-OPR_PENDING

3-Error

The slot [dec] is has pending operation, please try later.

The previous operation on this board has not completed

iosxe-chassismgr

Try with the same command later

CMRP-3-PEER_INVALID

3-Error

A peer table entry has invalid state.

A peer table entry has an invalid state. This could be due to a software defect or system resource exhaustion.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-PEM_REMOVE_SHUT

3-Error

The system will shut down in [dec] minutes

A power supply has been removed and the router will shutdown to protect itself from overheating in the amount of time stated in the error message.

iosxe-chassismgr

Reinsert a power supply into the power supply slot as soon as possible. The second power supply is required because the fans in the power supply are essential in monitoring router temperature.

CMRP-3-PFU_FAILURE

3-Error

Failed to handle power supply failure for [chars] in slot [dec], [chars]

A power supply has failed and the system is unable to properly handle the failure.

iosxe-chassismgr

Force an RP switchover if the system is configured with two RPs. If a switchover does not correct the problem or cannot be performed, reloading the router should resolve the issue.

CMRP-3-PFU_FAN

3-Error

Failed to handle fan failure for [chars] in slot [dec], [chars]

One or more fans have failed and the system is unable to properly handle the fan failure.

iosxe-chassismgr

Force an RP switchover if the system is configured with two RPs. If a switchover does not correct the problem or cannot be performed, reloading the router should resolve the issue.

CMRP-3-PFU_INCOMPATIBLE

3-Error

PFU Incompatible: [chars]

Error message for any PFU compatibility errors.

iosxe-chassismgr

Remove incompatible PSUs.

CMRP-3-PFU_INITIALIZATION

3-Error

The RP has failed to initialize a Power Supply/Fan module controller because [chars]

The RP failed to initialize a Power Supply or Fan module controller. This could be due to a hardware defect or C2W access failure.

iosxe-chassismgr

Note the time of the error message and examine the logs for C2W and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-PFU_MISSING

3-Error

The platform does not detect a power supply in slot [dec]

There is no power supply in one of the power supply slots.

iosxe-chassismgr

Insert a power supply into the empty slot. The router requires two power supplies because the fans in the power supply are needed to cool the router.

CMRP-3-PFU_OIR

3-Error

Failed to handle a [chars] oir event for PEM in slot [dec], [chars]

A power supply was inserted or removed into or from a router and the software did not properly handle the event.

iosxe-chassismgr

Force an RP switchover if the system is configured with two RPs. If a switchover does not correct the problem or cannot be performed, reloading the router should resolve the issue.

CMRP-3-POWERBUDGET

3-Error

not enough power budget left for : [chars]:[dec]

The system do not have enough power budget for the new card.

cbr-platform-infra

the message will be displayed when not enough power budget left for the new card inserted.

CMRP-3-PSU_INCOMPATIBLE

3-Error

The combination of Power Supply in P0: [chars] and P1: [chars] is not supported in power [chars] mode

An incompatible power supplies combination has been identified in P0 and P1 power supply slots. This could cause unpredictable behavior in power management in the router.

iosxe-chassismgr

This error indicates that the combination of the two power supplies in P0 and P1 is an unsupported combination. In order to fix this issue, please review the installation guide, plug out one of the power supplies based on the requirement. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-PWR_FAULT

3-Error

Shutting down [chars] because power fault on primary is [chars] and secondary is [chars]

The FRU has been shutdown as a result of a power issue.

iosxe-chassismgr

Check to ensure the router is receiving power. Otherwise, note the time of the error message and examine the logs for power-related errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-RP_MASTERSHIP_SET

3-Error

Failed to set RP mastership [chars] because [chars]

The router failed to establish RP mastership.

iosxe-chassismgr

Reload the router.

CMRP-3-RP_MISMATCH

3-Error

[chars] has been held in reset because the part number differs from that of the active RP

The part number read from the FRU IDPROM is not compatible with part number of the active RP; therefore, it may not act as a standby.

iosxe-chassismgr

Remove the FRU from the chassis.

CMRP-3-RP_RESET

3-Error

RP is resetting : [chars]

This RP is resetting due to the reason specified.

iosxe-chassismgr

No action is necessary.

CMRP-3-RP_SB_RELOAD

3-Error

Reload of Standby RP failed: [chars]

A request to reload the standby RP failed.

iosxe-chassismgr

Manually reload the standby RP. If that fails, configure SSO or RPR and then attempt the reload. If the problem persists, note the time of the error message and examine the Chassis Manager logs. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, show redundancy state, and the output of show tech-support and provide the gathered information to a Cisco technical support representative

CMRP-3-RP_SWITCH_SB_NOT_READY

3-Error

RP switchover: [chars]

An RP switchover occurred when the standby RP was not ready. The standby RP reset.

iosxe-chassismgr

No user action is necessary. Allow the standby RP to reset.

CMRP-3-SENSOR_INITIALIZATION

3-Error

Failed to initialize sensor monitoring because [chars].

Sensor monitoring failed to initialize.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-SENSOR_TYPE

3-Error

The sensor type is [dec] is invalid.

A sensor type is invalid. This could be due to a hardware defect, software defect or incorrect IDPROM content.

iosxe-chassismgr

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-SERDES_ESI_INIT_FAIL

3-Error

Serial Bridge ESI link [chars] between [chars] and [chars] failed to config

A Serial Bridge ESI link did not configure. This could be due to a software error.

iosxe-chassismgr

Note the time of the error message and examine the logs for Serial Bridge and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-SERDES_ESI_LOCK_FAIL

3-Error

Serial Bridge ESI link [chars] between [chars] and [chars] failed to lock

A Serial Bridge ESI link did not lock. This could be due to a hardware defect or a software configuration error.

iosxe-chassismgr

Note the time of the error message and examine the logs for Serial Bridge and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-SERDES_NSTEP_SYNC_ERROR

3-Error

Link down in Slot=[dec], Link-Type=[dec], Link-Status=0x%x, Link=[dec]

One or more Backplane Link didn't come up. This could be due to a hardware defect.

iosxe-chassismgr

Note the time of the error message and examine the logs for repeated SYNC errors after repeated retries. If the logs, provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-3-SIP_MDR_FAIL

3-Error

The SIP[dec] failed Minimal Disruptive Restart because [chars]

The SIP failed Minimal Disruptive Restart. Minimal Disruptive Restart process is aborted and an attempt will be made to recover the SIP by resetting the SIP hardware.

iosxe-chassismgr

Examine the system logs for errors.

CMRP-3-SOFT_ERROR_RELOAD

3-Error

Uncorrected Soft error on [chars], reloading RP to recover

Uncorrected Soft error on critical module, reloading the RP to recover

asr903-system

If this reoccures frequently, contact asr903-system

CMRP-3-SOFT_ERROR_RELOAD_RECOMMENDED

3-Error

Uncorrected Soft error on [chars], reload is recommended to recover.

Uncorrected Soft error on critical module, reload is recommended to recover

asr903-system

If this reoccures frequently, contact asr903-system

CMRP-3-SOFT_ERROR_UPDATE

3-Error

Critical soft error on [chars]

Update for each soft error on different components

asr903-system

If this reoccures frequently, contact asr903-system

CMRP-3-SOFT_ERROR_WAIT

3-Error

Uncorrected Soft error on [chars], waiting for standby to switchover

Uncorrected Soft error on critical module, waiting for standby to reach SSO to switchover

asr903-system

If this reoccures frequently, contact asr903-system

CMRP-3-SYS_REBOOT

3-Error

System going down, reason: [chars]

System reboot is called from software. Please check the reason and earlier syslog, traces

iosxe-chassismgr

Check the reason string and take appropriate action

CMRP-3-THROUGHPUT_LICENSE_APPLY_FAILED

3-Error

Throughput license look-up failed due to '[chars]'

This message is to notify the user that a license look-up did not succeed because license manager process could not be contacted. This is a rare case but is due to either a crashed license daemon(licensed) or it encountered an internal error.

iosxe-chassismgr

No user action is necessary. However, it is possible that a re-boot of the box may correct this behavior.

CMRP-3-UDI_AUTH

3-Error

Quack Unique Device Identifier authentication failed

This chassis seems to be compromised or tampered with. UDI burned on to the Quack chip and the one read from chassis EEPROM do not match. It can also be a case of either EEPROM or Quack device failure. More details about which specific field failed to match are logged in license daemon log file (licensed_R0.log).

iosxe-chassismgr

User immediately needs to contact Cisco support. This device appears to be tampered with or is a counterfeit device or had a system failure.

CMRP-3-UNSUPPORTED_FRU

3-Error

[chars] in slot [chars] is not supported with [chars] and so it is disabled

The Product ID read from the FRU IDPROM is not supported in this router. This is due to either Hardware or Software compatibility limitation indicated in the console log

iosxe-chassismgr

Remove the FRU from the chassis. Review the Hardware and Software Compatibility Matrix in IOS XE release notes to determine currently supported configurations.

CMRP-3-UNSUPPORTED_PEM

3-Error

[chars] in slot [chars] is not supported with [chars] and it needs to be replaced immediately

The Product ID read from the PEM IDPROM is not supported in this hardware configuration. It will be allowed to continue but immediate replacement is required

iosxe-chassismgr

Remove the PEM from the chassis and replace it with a supported PEM. Review the Hardware and Software Compatibility Matrix in IOS XE release notes to determine currently supported configurations.

CMRP-3-WANPLL_SETUP

3-Error

Failed to setup the [chars] of the RP WAN PLL because [chars]

Failed to setup the RP WAN PLL appropriately. This could be due to a hardware defect of the device.

iosxe-chassismgr

Note the time of the error message and examine the logs for WAN PLL related hardware errors. Check if the issue is transient or repeatable. If the problem is not recoverable collect the output of the error message and the chassis- manager and IOS logs. Provide the gathered information to a Cisco technical support representative.

CMRP-4-ACTIVE_SLOTBAY_BIAS

4-Warning

The configured active slot/bay bias [dec] is invalid.

The configured active slot/bay bias is not 0 or 1. The default value of 0 is used.

iosxe-chassismgr

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-4-CPP_WARN

4-Warning

Active cable linecard in slot [dec] has been physically removed.

Plug out one LC with heavy traffic, it may cause cpp queue pending drain and modem offline.

cbr-platform-infra

No action is required.

CMRP-4-FAN_TRAY_OVER_CURRENT

4-Warning

A Fan Tray over-current has been detected. System will be reset.

Internal error (Fan Tray over-current) condition was detected, and so the system was reset. If this error condition reoccurs, the hardware may need to be replaced.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-4-INTRUSION_ALERT

4-Warning

The system cover has been [chars] !!

These tamper alert message indicate the event of intrusion.

iosxe-chassismgr

LOG_STD_NO_ACTION

CMRP-4-MOTHERBOARD_OVER_CURRENT

4-Warning

Motherboard over-current has been detected. System will be reset.

Internal error (Motherboard over-current) condition was detected, and so the system was reset. If this error condition reoccurs, the hardware may need to be replaced.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-4-NGWICS_OVER_CURRENT

4-Warning

A NIM over-current condition has been detected. System will be reset.

Internal error (NIM over-current) condition was detected, and so the system was reset. If this error condition reoccurs, the hardware may need to be replaced.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-4-SERDES_ESI_CARD_RESEAT

4-Warning

Serial Bridge ESI link [chars] between [chars] and [chars] isn't locked; Card should be reseated

A Serial Bridge ESI link did not lock during first 10 reties due to improper seating.

iosxe-chassismgr

Note the time of the error message and examine the logs for Serial Bridge and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-4-SYSTEM_OVER_CURRENT

4-Warning

Overall system over-current has been detected. System will be reset.

Internal error (system over-current) condition was detected, and so the system was reset. If this error condition reoccurs, the hardware may need to be replaced.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-4-TAMPER_DETECTION_EVENT_MSG

4-Warning

System cover was opened [dec] times and closed [dec] times during power [chars] since last known event index [dec] at 20%02x/%02x/%02x %02x:%02x:%02x

These tamper warning indicate the event of intrusion.

iosxe-chassismgr

LOG_STD_NO_ACTION

CMRP-4-TAMPER_DETECTION_NO_LAST_KNOWN_EVENT

4-Warning

System cover was opened [dec] times and closed [dec] times during power [chars]. There is no last known/marked event.

These tamper warning indicate the event of intrusion.

iosxe-chassismgr

LOG_STD_NO_ACTION

CMRP-5-CHASSIS_MONITOR_BOOT_TIME_PRINT

5-Notice

Card [chars] took [dec] secs to boot

This is an informational message about boot time of all cards.

iosxe-chassismgr

Action is not necessary.

CMRP-5-FRU_CPLD_MISMATCH

5-Notice

CPLD ver [chars] in slot [chars] does not match Active CPLD ver [chars]

This FRU requires a matching CPLD firmware to function properly in this chassis

iosxe-chassismgr

Upgrade the CPLD firmware to have matching versions.

CMRP-5-HA_NOTICE

5-Notice

HA message: [chars]

HA Error Occured. This could be due to a software defect, please follow action

iosxe-chassismgr

Note the time of the error message and examine the logs for HA and hardware errors. Try re-inserting Standby SUP properly and see if problem gets corrected, If the problem is not correctable or the logs are not helpful, collect the the output of the error message,the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-5-NEBS_ACCESS_PID_FAIL

5-Notice

Failed to acess NGIO PID list for [chars] on slot/bay [dec]/[dec] in NEBS mode.

Unable to acess NGIO PID list for slot %d bay %d in NEBS mode

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-5-PEM_OUTPUT_DETECT

5-Notice

Output of PEM [dec] is [dec] V

Value of Output of PEM.

cbr-platform-infra

If PEM Output is 0, check Power Cable.

CMRP-5-PRERELEASE_HARDWARE

5-Notice

[chars] is pre-release hardware

The board does have an official production part number.

iosxe-chassismgr

Immediately contact Cisco for a replacement board.

CMRP-5-SUDI_KEY_READ_INIT_FAILED

5-Notice

SUDI(SHA2) key read failed during Initializtion.

SHA key read failed during Initializtion.

iosxe-chassismgr

Check SUDI Trustpoint creation. Please collect output of show tech-support and provide the gathered information to a Cisco technical support representative.

CMRP-5-UNSUPPORTED_MODULE

5-Notice

Unsupported Module inserted. The module [chars] on the slot [dec] may not be a genuine Cisco product. Cisco warranties and support programs only apply to genuine Cisco products. If Cisco determines that your insertion of non-Cisco memory, WIC cards, AIM cards, Network Modules, SPA cards, GBICs or other modules into a Cisco product is the cause of a support issue, Cisco may deny support under your warranty or under a Cisco support program.

Hardware in the specified location could not be identified as a genuine Cisco product

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-5-UNSUPPORTED_MODULE_IN_NEBS

5-Notice

The module [chars] on slot/subslot [dec]/[dec] is not supported in NEBS power mode.

Hardware in the specified location should be removed in NEBS mode

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP-6-DUAL_IOS_REBOOT_REQUIRED

6-Information

Configuration must be saved and the chassis must be rebooted for IOS redundancy changes to take effect

Chassis manager received notification that IOS software redundancy has been configured. For these changes to take effect, the system must be restarted.

iosxe-chassismgr

Reload the chassis.

CMRP-6-DUAL_IOS_STARTING

6-Information

Software redundant IOS configured; starting standby in [dec] seconds.

Chassis manager received notification that IOS software redundancy has been configured. The standby IOS will be started in the time specified.

iosxe-chassismgr

No action is necessary.

CMRP-6-DUAL_IOS_STOPPING

6-Information

Bringing down standby IOS

Chassis manager received notification to stop the standby IOS instance. This may be for a redundancy mode change. Depending on the reason, the standby may be subsequently restarted.

iosxe-chassismgr

No action is necessary.

CMRP-6-FORCE_RESET_OTHER_RP

6-Information

The other SUP RP [dec] is still holding the midplane lock to block the suppervisor failover, force reset it to release the midplane lock.

The Other Supvervisor is force reset due to hold the midplane lock for a long time during supervisor failover

iosxe-chassismgr

No action is required. This is informational message

CMRP-6-FP_HA_SB_NOTREADY

6-Information

FP switchover: F[dec] [chars]

The standby ESP is not ready for a switchover.

iosxe-chassismgr

No user action is necessary.

CMRP-6-FP_HA_STATUS

6-Information

F[dec] redundancy state is [chars]

The ESP has transitioned into a new High Availability state.

iosxe-chassismgr

No user action is necessary. This is an informational message.

CMRP-6-FP_SB_RELOAD_REQ

6-Information

Reloading Standby FP: [chars]

A reload of Standby FP has been requested.

iosxe-chassismgr

No action is necessary.

CMRP-6-FRU_FPGA_UPG_REQUIRED

6-Information

[chars] in slot [chars] has INCOMPATIBLE FPGA firmware version with [chars]. Upgrade the FPGA firmware

This FRU requires a newer FPGA firmware to function properly in this chassis

iosxe-chassismgr

Upgrade the FPGA firmware on this FRU using the <b> upgrade hw-programmable FPGA file <pkg_file> slot <fru_slot> </b> command.

CMRP-6-FRU_HWPRG_CPLD_POSTUPG_SUCCESS

6-Information

Hardware CPLD postupgrade on CLC[dec] was successfully programmed.The LC is reloading to make it take effect.

The hw-programmable CPLD postupgrade was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMRP-6-FRU_HWPRG_UPG_ADM1266_FM_START

6-Information

Hardware programmable ADM1266s on [chars] in slot [chars] are upgrading, please don't reload or power-cycle this card. It will take about 10 mins to finish.

The hw-programmable ADM1266 Firmware is upgrading

iosxe-chassismgr

No action is required. This is informational message

CMRP-6-FRU_HWPRG_UPG_ADM1266_FM_SUCCESS

6-Information

Hardware programmable ADM1266s on [chars] in slot [chars] were successfully programmed. The card is reloading to make them work

The hw-programmable ADM1266 fimware was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMRP-6-FRU_HWPRG_UPG_PSOC_DONE

6-Information

Hardware programmable PSOCs on [chars] in slot [chars] were upgraded successfully

The hw-programmable PSOC was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMRP-6-FRU_HWPRG_UPG_PS_SUCCESS

6-Information

Power-Supply Module MCUs in slot [chars] were successfully programmed.

The hw-programmable power-supply was upgraded succesfully

iosxe-chassismgr

No action is required. This is informational message

CMRP-6-FRU_HWPRG_UPG_START

6-Information

Hardware programmable [chars] on [chars] in slot [chars] is upgrading. please don't reload or power-cycle this card. It will take about 5 mins to finish.

The hw-programmable was upgrading

iosxe-chassismgr

No action is required. This is informational message

CMRP-6-HT_CLOSURE_MODE

6-Information

The HTPI driver failed to set it's closure mode properly

This is not a critical error, but it will result in possible traffic interruption during certain software failure cases or ISSU operations.

iosxe-chassismgr

Note the error message and contact a Cisco technical support representative.

CMRP-6-HT_STATUS

6-Information

R[dec] hypertransport configured for F[dec] active

The RP HyperTransport driver was properly configured for a newly active FP.

iosxe-chassismgr

No user action is necessary. This is as informational message indicating normal system operation.

CMRP-6-IGNORE_PFU_OIR

6-Information

Simulating FAN OIR due to FAN Speed profile change

FAN tray OIR is simulated throught software to select new FAN SPEED profile. this message is to let know the user that this is a simulated FAN oir and not physical FAN oir. User needs to ignore next occurrence messages/alarms associated with FAN tray removal/insertion actions. such as FAN tray missing, PEM/FAN removed/inserted and system shutdown will happen messages

asr903-system

ignore FAN tray or PEM/FM removal/insertion messages and system shutdown message

CMRP-6-MGMT_SFP_INSERT

6-Information

transceiver module inserted in [chars]

The online insertion and removal (OIR) facility detected a newly inserted transceiver module for the interface specified in the error message.

iosxe-chassismgr

No action required.

CMRP-6-MGMT_SFP_REMOVED

6-Information

Transceiver module removed from [chars]

The online insertion and removal (OIR) facility detected the removal of a transceiver module from the interface specified in the error message.

iosxe-chassismgr

No action required.

CMRP-6-MODULE_INSERTED_CFG_MISMATCH

6-Information

The module inserted in Switch:[dec] Slot:[dec] doesn't support the configured Stackwise Virtual link/Dual Active Detection Link Speed. Line card is Power denied. Please replace the Line card with the configured SVL/DAD link speed or remove the config and reload the system

The Line Card and SVL/DAD CONFIG in the slot mismatch.

iosxe-chassismgr

Change the config and reload the system or remove the Line card.

CMRP-6-REDT_FP_UNSUPPORTED_IN_INTER_CHASSIS_MODE

6-Information

[chars] redundant FP in slot [chars] is not supported in inter-chassis redundancy mode

Because the system is configured in box-to-box or inter-chassis redundancy mode, the intra chassis redundancy mode is not supported and redundant FP, if any, will be disabled.

iosxe-chassismgr

No user action is necessary.

CMRP-6-REDT_RP_UNSUPPORTED_IN_INTER_CHASSIS_MODE

6-Information

[chars] redundant RP in slot [chars] is not supported in inter-chassis redundancy mode. Please remove it for inter-chassis redundancy to work properly on system reload.

Because the system is configured in box-to-box or inter-chassis redundancy mode, the intra chassis redundancy mode is not supported and redundant RP, if any, will be disabled.

iosxe-chassismgr

No user action is necessary.

CMRP-6-RFROLE

6-Information

RP switchover, [chars]

On RP switchover chasfs rfrole property has been changed.

iosxe-chassismgr

No user action is necessary.

CMRP-6-RP_SB_RELOAD_REQ

6-Information

Reloading Standby RP: [chars]

A reload of Standby RP has been requested.

iosxe-chassismgr

No action is necessary.

CMRP-6-RP_SWITCH_SB_SYNC

6-Information

RP switchover: [chars]

The RP switch synchronization timer expired.

iosxe-chassismgr

No user action is necessary.

CMRP-6-SINGLE_IOS_REBOOT_RECOMMENDED

6-Information

Configuration must be saved and the chassis should be rebooted for optimal single-IOS execution

Chassis manager received notification that IOS software redundancy has been unconfigured. For optimal runtime resource allocation, the system must be restarted.

iosxe-chassismgr

Reload the chassis.

CMRP-6-STBY_HARDDISK_UNAVAIL

6-Information

stby-harddisk is offline

The stby-harddisk is not available.

iosxe-chassismgr

No user action is necessary. This is an informational message.

CMRP-6-TEST_SPA_OIR_ONLINE_INSERT_DENIED

6-Information

SPA [dec]/[dec] oir insert is denied

test command executed disallowing the spa to be inserted.

iosxe-chassismgr

Execute the test command allowing the insertion of the spa for normal operation

CMRP-6-TEST_SPA_OIR_ONLINE_OPS

6-Information

SPA [dec]/[dec] oir online status is set to [chars]

test command executed to either allow/deny the spa coming online.

iosxe-chassismgr

If the card does not come online, execute the test command to allow the spa to come online.

CMRP-6-THROUGHPUT_LICENSE

6-Information

Throughput license [chars], throughput set to [chars]

Status indicating whether throughput license is found and the corresponding througput the CPP hardware is configured to provide.

iosxe-chassismgr

No user action is necessary. This is an informational message indicating throughput configured.

CMRP_ENVMON-3-PWR_FRU_HW_AUTO_SHUTDOWN

3-Error

WARNING: The card on slot [dec] hit abnormal voltage or current. it has been auto-shutdown by hardware for protection

The FRU hit abnormal voltage or current and has been auto-shutdown in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-3-TEMP_FRU_HW_AUTO_SHUTDOWN

3-Error

WARNING: The card on slot [dec] is overheating. it has been auto-shutdown by hardware for protection

The FRU is overheating and has been auto-shutdown in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-3-TEMP_FRU_SHUTDOWN_NOW

3-Error

WARNING: [chars] temperature sensor on [chars] is in a shutdown FRU state. FRU shutdown now.

The FRU is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-3-TEMP_FRU_SHUTDOWN_PENDING

3-Error

WARNING: [chars] temperature sensor on [chars] is in a shutdown FRU state. FRU shutdown will occur in [dec] minutes.

The FRU is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-3-TEMP_PSU_SHUTDOWN_NOW

3-Error

WARNING: [chars] temperature sensor on [chars] is in a shutdown PSU state. PSU shutdown now.

The PSU is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-3-TEMP_SYS_SHUTDOWN_NOW

3-Error

WARNING: [chars] temperature sensor on [chars] is in a shutdown SYS state. System shutdown now.

The FRU is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-3-TEMP_SYS_SHUTDOWN_PENDING

3-Error

WARNING: [chars] temperature sensor on [chars] is in a shutdown SYS state. System shutdown will occur in [dec] minutes.

The FRU is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-3-TEMP_WARN_CRITICAL

3-Error

WARNING: [chars] temperature sensor on [chars] is in a critical state reading [dec]

The FRU is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-3-TRANSCEIVER_TEMP_SYS_SHUTDOWN_NOW

3-Error

WARNING: transceiver temperature sensor is in a shutdown SYS state. System shutdown now %x.

The Transceiver is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_ENVMON-6-TEMP_SYS_SHUTDOWN_DISABLED

6-Information

WARNING: System is in a thermal shutdown disabled state. System won't shut down now.

Thermal shutdown disable is configured to bypass system shutdown.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-1-FAN_POLICY_ALERT

1-Alert

SYSTEM FAN POLICY Alert : [chars]

System FAN policy check detect issues

iosxe-chassismgr

Monitor or Replace faulty fan modules may be needed.

CMRP_PFU-1-PFU_FAN_FAILED

1-Alert

System detected fan tray removal or fan failure, reinsert or service the faulty fan tray to avoid system shutdown due to high temperature.

Fan tray has been removed or one of the fan failed and the router will shutdown when the temp reaches Critical temperature to protect itself from overheating.

iosxe-chassismgr

Reinsert a fan tray into the fan tray slot as soon as possible.

CMRP_PFU-1-PFU_NO_FAN

1-Alert

System detected no fan or fan tray available, either not present or in failure state. Reinsert or service the faulty fan or fan tray to avoid system shutdown.

No working fan or fan tray detected in the system, could be removed or in failure state, switch will be shutdown when the temp reaches critical temperature to protect itself from overheating.

iosxe-chassismgr

Reinsert working fan or fan tray as soon as possible.

CMRP_PFU-2-PSU_VOLATGE_MIX

2-Critical

Mix of 110V and 220V is not supported configuration, PSU in slot [chars] is in 110V and PSU in slot [chars] is in 220V. This can cause system reload, Connect the same voltage input to avoid system reload immediately.

Some PSUs are connected to 110V and some are connected to 220V. This is not supported from hardware as it may cause system failure and system may go for reload. Input voltage can be checked using CLI show platform hardware chassis power-supply detail

iosxe-chassismgr

Connect all the power supplies to same voltage input source as soon as possible.

CMRP_PFU-3-DCPOWERREDUNDANCY

3-Error

dc input [chars] failed for pem: [dec]

The DC input failed for pem module.

iosxe-chassismgr

the message will be displayed when DC input failed.

CMRP_PFU-3-FANASSY_REMOVED

3-Error

Fan Assembly is removed. Please insert to avoid system from heating.

Fan Assembly has been removed from the system. It needs to be inserted back to prevent system from heating. If the system over heats, parts of the system will not function normally and system may shut itself down.

iosxe-chassismgr

Insert the fan assembly in the system to prevent system from over heating.

CMRP_PFU-3-PEM_STATUS

3-Error

WARNING: The power supply module on slot [dec] hits [chars],

The power supply module are not functioning properly.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PEM_VOLTAGENOTSUPPORTED

3-Error

WARNING: Input voltage of power supply module on PS[dec] is not supported. Please use the supported range of either [dec]-[dec] volts for [dec]W or [dec]-[dec] volts for [dec]W

The input voltage of the power supply module is out of range

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PFU_FANS_DEAD

3-Error

The fans in the [chars] in slot [dec] have all failed.

The system is in danger of overheating because none of the fans in one of the PEMs are working properly.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PFU_FANS_DEAD_SHUTDOWN

3-Error

Shutting down system now because the fans in slot [dec] have all failed.

When the fans fail then system does not have sufficient cooling capacity. To prevent damage, the system will automatically shut down.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PFU_FAN_DEAD

3-Error

WARNING: Fan [dec] in the [chars] in slot [dec] has failed.

A fan is not functioning properly.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PFU_FAN_ERR

3-Error

WARNING: Fan [dec] in slot [dec] has the error: [chars], Please replace it with a new fan.

A fan is not functioning properly.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PFU_IDPROM_CORRUPT

3-Error

The PEM/FM idprom could be read, but is corrupt in slot P[dec] The system will run without environmental monitoring for this component

The idprom contains information required in order to properly operate the environmental monitoring subsystems. The idprom could not be read, therefore no monitoring will take place.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PFU_IDPROM_READ_ERR

3-Error

Could not read the PEM/FM idprom in slot P[dec]. The system will run without environmental monitoring for this component

The idprom contains information required in order to properly operate the environmental monitoring subsystems. The idprom could not be read, therefore no monitoring will take place.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PFU_SHUTDOWN

3-Error

Shutting down system now because the PEM in slot [dec] was removed or not seated correctly.

When either a PEM or a FM are removed, the system lacks sufficient cooling capacity. To prevent damage, the system will automatically shut down unless it is replaced.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PFU_SLOT_VACANT

3-Error

The platform does not detect a power supply in slot [dec]

There is no power supply in one of the power supply slots.

iosxe-chassismgr

Insert a power supply into the empty slot.

CMRP_PFU-3-PWR_MGMT_ALARM

3-Error

WARNING: System does not have sufficient input power for minimum reliable operation requiring [dec] watts. The system needs [dec] watts of additional power.

System power does not meet minimum requirements. Insert additional power supplies or provide current power supplies with a greater input voltage source if applicable.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PWR_MGMT_LC_SHUTDOWN

3-Error

WARNING: Linecard in slot [dec] with priority [dec] and a power requirement of [dec] watts has shutdown.

A LC was shutdown due to a power loss.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PWR_MGMT_SINGLE_SUP_ERROR

3-Error

ERROR: Remote supervisor has been detected in slot [dec]. System is configured to SINGLE-SUP power mode. Remove remote supervisor IMMEDIATELY.

User inserted a second supervisor in a single-sup power mode.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PWR_PROTECTION_ACTION

3-Error

Shutdown the card [chars] due to insufficient power budget.

The total power is not enough, shutdown FRUs for power protection.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PWR_PROTECTION_MODE

3-Error

WARNING: Detected low input voltage ([dec]V) on the power supply in slot P[dec], the power budget may not be enough, some cards may be shutdown due to the power budget reduction. Please check the power input.

Input voltage of power supply is too low.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-PWR_REDUN_ALARM_STATE

3-Error

WARNING: An active power supply has failed and the system has entered alarm state. The system is operating without power redundancy and has [dec] watts of power remaining

An active power supplied failed while in redundant power mode.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-SHUTDOWN_FAILURE

3-Error

The system attempted to shut itself down, but failed because [chars]

The system reached a condition where it should be shut down, but the shutdown call failed. The system should be manually rebooted.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-TEMP_FRU_SHUTDOWN

3-Error

[chars] temperature sensor on [chars] is in a shutdown FRU state. FRU shutdown will occur in [dec] minutes.

The FRU is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-3-TEMP_SYSTEM_SHUTDOWN

3-Error

[chars] temperature sensor is in a shutdown system state. System shutdown will occur in [dec] minutes.

The system is overheating and will be shut down in order to protect the components.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-4-PFU_FANTRAY_WARN

4-Warning

WARNING: Fantray in slot [chars] has the error: [chars].

A fantray is not functioning properly.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-4-PFU_FAN_ID_WARN

4-Warning

WARNING: [chars] of [chars] has an error: [chars]

A fan is not functioning properly.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-4-PFU_FAN_INSUFFICIENT

4-Warning

WARNING: Insufficient number of fan modules installed. There are only [dec] fan modules, expecting [dec]

Insufficient number of fan modules installed, should insert new fans as soon as possible to avoid system from over heating.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-4-PFU_FAN_TRAY_WARN

4-Warning

WARNING: Fan tray in slot [dec] has the error: [chars].

A fan tray is not functioning properly.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-4-PFU_FAN_WARN

4-Warning

WARNING: Fan [dec] in slot [dec] has the error: [chars].

A fan is not functioning properly.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-4-PWR_MGMT_CAPACITY_MIXED

4-Warning

System contains power supplies of mixed power capacity. Redundancy operating mode Full protected is not supported with this configuration. System will run in Normal protected state.

HW does not support Full protected mode with mixed capacity power supplies. This is due to current sharing; specifically dealing with the case in which all active power supplies fail simultaneously. Full protected state is demoted to Normal protected state.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-4-PWR_MGMT_WARN

4-Warning

WARNING: Insufficient number of power supplies ([dec]) are installed for power redundancy mode [chars]. The system needs [dec] watts additional power.

Insufficient number of power supplies are installed. Should insert new power supplies as soon as possible

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-5-DCPOWERINPUT

5-Notice

dc input [chars] recovered for pem: [dec]

The DC input recovered for pem module.

iosxe-chassismgr

the message will be displayed when DC input recovered.

CMRP_PFU-6-FANASSY_INSERTED

6-Information

Fan Assembly is inserted.

Fan Assembly that was previously removed has been inserted in the system. Preventing the system from over heating is important. So fan assembly should not be removed for extended period of time during normal operation.

iosxe-chassismgr

No further action is necessary.

CMRP_PFU-6-PEM_INSERTED

6-Information

Power Supply in slot [dec] not operational.

A PEM seems to be inserted without the power cable connected. This message is a notice that the power supply is not operational, will not provide power to the system, and may not be completely detected by the software until the power cable is connected and the PEM is supplied with the power.

iosxe-chassismgr

Insert the power supply cable in the PEM and provide power.

CMRP_PFU-6-PFU_BEACON_LED_ON_OFF

6-Information

[chars] [dec] beacon LED is TURNED [chars].

Power Supply or Fan-tray, Beacon LED turned ON/OFF. This is a notification message only.No action is required.

iosxe-chassismgr

This is a notification message only. No action is required.

CMRP_PFU-6-PFU_FAN_DETECTED

6-Information

The required number of fan trays or fan modules are detected.

After previous no fan or insufficient fan modules alarm, the required minimum number of fan trays or fan modules have been detected.

iosxe-chassismgr

No further action is required.

CMRP_PFU-6-PFU_FAN_RECOVERED

6-Information

Fan in slot [dec] has been recovered from error conditions, Now it's working normally.

Fans are just recovered from an error condition,

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PFU_FAN_RECOVERED_I2C

6-Information

Successfully restored I2C communication to PSoC [dec] on fan module in slot [dec].

Fans are just recovered from an I2C communcation.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PFU_INSERTED

6-Information

[chars] inserted. System shutdown aborted.

When either a PEM or a FM are removed, the system lacks sufficient cooling capacity. To prevent damage, the system will automatically shut down unless it is replaced.This message serves as notice that the module has been replaced within the required time

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PSU_VOLATGE_MIX_RECOVERED

6-Information

All PSUs are now connected to the same input voltage. System has recovered from mix of input voltages. PSU in slot [chars] is connected to [chars]

Some PSUs were connected to 110V and some were connected to 220V. This was not supported from hardware as it may have caused system failure. The system is now in a stable state with all PSUs connected to the same input voltage

iosxe-chassismgr

All the power supplies should be connected to same input voltage source

CMRP_PFU-6-PWR_MGMT_LC_RECOVERED

6-Information

Linecard in slot [dec] with priority [dec] has been recovered from shutdown

A LC was recovered from a shutdown

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PWR_MGMT_NON_REDUNDANT

6-Information

Changing the power redundancy mode to non-redundant

Changing the power redundancy mode to non-redundant

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PWR_MGMT_OK

6-Information

Sufficient number of power supplies ([dec]) are installed for power redundancy mode [chars] (excess power [dec] watts).

Sufficient number of power supplies are installed.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PWR_MGMT_REDUNDANT

6-Information

Changing the power redundancy mode to redundant.

Changing the power redundancy mode to redundant

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PWR_MGMT_SINGLE_SUP_NOTICE

6-Information

NOTICE([dec] of [dec]): System is now running in SINGLE-SUP power budget mode. Insertion of the remote supervisor is not supported in this power mode. System may shutdown if second supervisor is inserted.

User needs to be notified that single-sup mode is enabled

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PWR_PROTECTION_RECOVERED

6-Information

The power supply in slot P[dec] has been recovered from the power protection mode.

Power supply input are just recovered from an error condition,

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PWR_REDUN_RECOVERED

6-Information

System has recovered from the alarm state and has [dec] watts of power remaining

User has recovered the system from the alarm state triggered by a power failure

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CMRP_PFU-6-PWR_UP_FRU

6-Information

Power up the card [chars] due to power budget change.

The total power become enough, power FRUs.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

CONFIG_VALIDATOR_MESSAGE-5-EWLC_GEN_ERR

5-Notice

Error in [chars]

EWLC wireless config db Error Message.

iosxe-binos-utils

LOG_STD_ACTION

CSVERIFY-3-CSVERIFY_FAIL

3-Error

Signature verification: [[chars]]

During digital signature verification, an error has occured

iosxe-binos-utils

Check the diagnostic csverify trace file for more information on the underlying failure.

CSVERIFY-6-CSVERIFY_SUCCESS

6-Information

Signature verification success for [chars]

Signature verification was successful for the file mentioned.

iosxe-binos-utils

This is an informational message. No action is required.

CXPD-3-MAX_LOCAL_EXIT_EXCEEDED

3-Error

Maximum local exit: [dec] exceeded, failed to initialize application: [chars] (interface: [chars])

This syslog is generated when the number of DIA exits exceed maximum supported value. SaaS app initialization will fail because of this reason

cedge-cxp

CXP has reached the maximum number of probes it can handle. Need to disable either some applications or the links in which CoR SaaS is enabled

CXPD-5-APP_CHANGE

5-Notice

Application: [chars] exit changed from ([chars] via [chars]) local-color [chars] remote-color [chars] to ([chars] via [chars]) local-color [chars] remote-color [chars] from [dec]/[dec] to [dec]/[dec] (latency/loss)

This log is generated whenever exit for a SaaS application changes from one TLOC to another TLOC

cedge-cxp

No action is required

CXPD-5-SCORE_CHANGE

5-Notice

Application: [chars] ([chars] exit via [chars]), local-color: [chars], remote-color: [chars], score changed from [dec]/[dec] to [dec]/[dec] (latency/loss)

This syslog is generated whenever the score (loss/latency combination) changes for SaaS application over given TLOC

cedge-cxp

No action is required

DBAL-3-BIPC_MSG_ALLOC_FAIL

3-Error

BIPC msg size too big to allocate

BIPC msg size beyond limit.

polaris-infra

Report this occurance to Cisco TAC

DBAL-3-MQIPC_ADVANCEERR

3-Error

MQIPC advance error [[chars]] reader [[chars]]

MQIPC fails to advance to the next msg in DBAL

polaris-infra

Report this occurance to Cisco TAC

DBAL-3-MQIPC_EVENTLOSS

3-Error

MQIPC event lost reader [[chars]]

MQIPC event notifying of non-empty queue not delivered to DBAL

polaris-infra

Report this occurance to Cisco TAC

DBAL-3-MQIPC_PEEKERR

3-Error

MQIPC peek error [[chars]] reader [[chars]] err_msg [[chars]]

MQIPC fails to peek and fetch a msg in DBAL

polaris-infra

Report this occurance to Cisco TAC

DBAL-3-MQIPC_READER_INIT_BY_TIMER

3-Error

MQIPC reader [chars] initialized by timer not chasfs watcher.

MQIPC reader initialized by timer not chasfs watcher.

polaris-infra

Report this occurance to Cisco TAC

DBAL-4-LONG_EXEC_BATCH

4-Warning

Long exec [[dec]:[dec]] create:exec:now [[dec]:[dec]:[dec]] e:p [[dec]:[dec]] resumes [[dec]] peer [[chars]]

DBAL batch execution took an extended period of time. This may or may not be a problem depending on the circumstances

polaris-infra

Collect log archive and show tech-support and report this occurance to Cisco TAC

DBAL-6-DELAYED_BATCH

6-Information

Delayed batch [[dec]:[dec]] create:exec:notif:now [[dec]:[dec]:[dec]:[dec]] eproc [[dec]] e:p [[dec]:[dec]] peer [[chars]]

DBAL batch with an extended lifetime. This can occur when large amounts of data and/or operations are being performed.

polaris-infra

If this is causing impact to any service, collect log archive and show tech-support and report this occurance to Cisco TAC. Otherwise, safe to ignore.

DBGD-3-SYNTHETIC_TEST_PROBE_DNS_ERR

3-Error

DNS server is [chars], [chars] interface not valid in VRF: [chars]

This error syslog is generated during synthetic test probes when FQDN cannot be resolved due to errors in DNS config

cedge-srvcability

No action is required

DBGD-5-INTERFACE_AUTO_BW

5-Notice

Interface [chars] (vpn: [dec]) bandwidth determined by auto speedtest, upstream b/w: [dec] bps, downstream b/w: [dec] bps

This notice syslog is generated whenever upstream or downstream bandwidth of an interface is auto adjusted

cedge-srvcability

No action is required

DBGD-5-SYNTHETIC_TEST_PROBE_RESULT

5-Notice

Synthetic test probe result for app: [chars], url: [chars], src_intf: [chars], latency: [dec], loss: [dec]%%, score: [dec], count [dec]

This notice syslog is generated once synthetic test probe finishes measuing loss and latency to given SaaS application

cedge-srvcability

No action is required

DC_DYNAMIC_XML_LOG-3-DC_DYNAMIC_XML_CANNOT_GET_XML_FILE_SIZE

3-Error

Unable to get file size of dynamic XML file dc_user_profiles.xml

Unable to get file size of dynamic XML file dc_user_profiles.xml

ewlc-client

LOG_STD_ACTION

DC_DYNAMIC_XML_LOG-3-DC_DYNAMIC_XML_CANNOT_LOAD_XML

3-Error

Unable to load dynamic XML file dc_user_profiles.xml

Unable to load dynamic XML file dc_user_profiles.xml

ewlc-client

LOG_STD_ACTION

DC_DYNAMIC_XML_LOG-3-DC_DYNAMIC_XML_CANNOT_OPEN_XML_FILE

3-Error

Unable to open dynamic XML file dc_user_profiles.xml

Unable to open dynamic XML file dc_user_profiles.xml

ewlc-client

LOG_STD_ACTION

DC_DYNAMIC_XML_LOG-3-DC_DYNAMIC_XML_CANNOT_PARSE_XML

3-Error

Unable to parse dynamic XML file dc_user_profiles.xml

Unable to parse dynamic XML file dc_user_profiles.xml

ewlc-client

LOG_STD_ACTION

DMI-2-CDB_MAN_SUB_FAIL

2-Critical

Failed to register as mandatory subscriber [chars] ([dec]): [chars]

A Confd error has occurred attempting to mark DMI as a mandatory subscriber

ddmi-infra

Stop and restart netconf-yang.

DMI-2-CHG_VRF_FAIL

2-Critical

The DMI application failed to set the correct virtual routing and forwarding network.

The DMI application failed to set the correct virtual routing and forwarding network; thus, it cannot communicate with Confd.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-CLI_CHANNEL_CLOSED

2-Critical

CLI engine event channel closed unexpectedly ([dec]): [chars].

The CLI engine event channel to the network element closed unexpectedly.

ddmi-infra

DMI will reset. No action necessary.

DMI-2-CONFD_CB_REG_DONE_FAIL

2-Critical

Failed to complete callback registration [chars] ([dec]): [chars].

A DMI application cannot complete callback registration with Confd.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-CONFD_CB_REG_FAIL

2-Critical

Failed to register callback with Confd [chars] ([dec]): [chars].

A DMI application cannot register a particular callback with Confd.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-CONFD_CONNECT_FAIL

2-Critical

Failed to connect to Confd via [chars] socket [chars] ([dec]): [chars].

A DMI application cannot connect to Confd via a particular socket type.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-CONFD_INIT_FAIL

2-Critical

Failed to initialize Confd [chars] ([dec]): [chars].

Confd did not initialize properly.

ddmi-infra

Back out any recent yang model updates. Stop and restart netconf-yang.

DMI-2-CONFD_SUB_DONE_FAIL

2-Critical

Failed to complete subscription [chars] ([dec]): [chars].

A DMI application cannot complete subscriptions for changes to yang models.

ddmi-infra

Back out any recent model updates. Stop and restart netconf-yang.

DMI-2-CONFD_SUB_FAIL

2-Critical

Failed to subscribe [chars] model [chars] ([dec]): [chars].

A DMI application cannot subscribe for changes to a particular yang model.

ddmi-infra

Back out any recent model updates. Stop and restart netconf-yang.

DMI-2-CONTROL_SOCKET_ERROR

2-Critical

Confd control socket ready check returned an error [chars] ([dec]): [chars].

The control socket connection to Confd has returned an error.

ddmi-infra

DMI will reset. No action necessary.

DMI-2-MAAPI_CONNECT_FAIL

2-Critical

Could not connect to Confd via DMI MAAPI socket [chars] ([dec]): [chars].

A Confd error has occurred attempting to connect via MAAPI socket.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-MAAPI_WAIT_FAIL

2-Critical

Wait for Confd to initialize to phase two failed [chars] ([dec]): [chars].

Confd did not initialize properly.

ddmi-infra

Back out any recent yang model updates. Stop and restart netconf-yang.

DMI-2-NESD_CREATE_FAIL

2-Critical

Failed to create nes daemon.

Either an out-of-memory condition has been encountered, or the DMI CLI engine cannot connect to the network element.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-NESD_INIT_FAIL

2-Critical

Failed to initialize the network element synchronizer daemon

The nesd daemon failed to initialize.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-NESD_PREHOOK_INIT_FAIL

2-Critical

Failed to initialize component-specific add-ons to the network element synchronizer daemon

The nesd daemon failed to initialize its component-specific add-ons.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-NES_RESET_FAIL

2-Critical

Failed to reinitialize the DMI network element synchronizer daemon.

The network element synchronizer daemon cannot reset in order to recover from a critical error.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-NETCONF_SSH_CRITICAL

2-Critical

NETCONF/SSH: [chars]

A critical message from the NETCONF SSH daemon.

ddmi-infra

Not applicable

DMI-2-NOTIFICATION_READ_FAIL

2-Critical

Failed to read notification [chars] ([dec]): [chars].

An attempt to read an event from the Confd notification socket failed.

ddmi-infra

DMI will reset. No action necessary.

DMI-2-RUNNING_DATASTORE_INVALID

2-Critical

Running datastore is invalid due to configuration failure during commit phase.

IOS configuration failed during commit phase of the transaction. As a result, running datastore is not in sync with IOS configuration. Configuration to IOS is not allowed until datastore becomes valid after full sync.

INVALID

Device will perform full-sync. CDB lock must be released by the controler to unblock full-sync.

DMI-2-SD_INIT_FAIL

2-Critical

Failed to initialize the syncfd daemon

The syncfd daemon failed to initialize.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-SD_RESET_FAIL

2-Critical

Failed to reinitialize the DMI syncfd daemon.

The syncfd daemon cannot reset in order to recover from a critical error.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-VTY_SERVER_RESET_FAIL

2-Critical

Failed to reinitializie VTY server utility instance.

Failed to reset VTY server utility in order to recover from critical error.

ddmi-infra

Stop and restart netconf-yang.

DMI-2-WORKER_SOCKET_CLOSED

2-Critical

Confd worker closed unexpectedly [chars] ([dec]): [chars].

The worker socket connection to Confd has closed unexpectedly.

ddmi-infra

DMI will reset. No action necessary.

DMI-2-WORKER_SOCKET_ERROR

2-Critical

Confd worker socket ready check returned an error [chars] ([dec]): [chars].

The worker socket connection to Confd has returned an error.

ddmi-infra

DMI will reset. No action necessary.

DMI-3-AUTH_TIMED_OUT

3-Error

[chars] request from [chars]:[chars] for [chars] over [chars] timed out.

A AAA request timed out.

ddmi-infra

Check connectivity to the configured AAA server.

DMI-3-CDB_ABORT_FAIL

3-Error

Failed to abort transaction [chars] ([dec]): [chars].

A Confd error has occurred attempting to abort a transaction.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-CDB_READ_FAIL

3-Error

Could not read the yang path '[chars]' from the DMI data store [chars] ([dec]): [chars].

A Confd error has occurred attempting to read a specific model path from the DMI data store.

ddmi-infra

Download the model in question from the network element and verify the path exists. Update the model if needed.

DMI-3-CDB_SET_NAMESPACE_FAIL

3-Error

Could not set the model namespace '[chars]' for accessing the DMI data store [chars] ([dec]): [chars].

A Confd error has occurred attempting to set a specific model namespace for accessing the DMI data store.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-CDB_START_FAIL

3-Error

Could not start session to read configuration from the DMI data store [chars] ([dec]): [chars].

A Confd error has occurred attempting to open the DMI data store.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-CDB_SYNC_FAIL

3-Error

Confd subscription socket sync failed [chars] ([dec]): [chars].

A Confd error has occurred attempting to sync the subscription socket.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-CLI_ENGINE_CONNECT_FAIL

3-Error

Failed to connect to network element.

DMI cannot connect to the network element in order to interact with its CLI parser.

ddmi-infra

Check the CLI engine protocol settings.

DMI-3-CLI_ENGINE_CONNECT_LOSS

3-Error

Detected connection to the network element has been lost. Attempting to reconnect

DMI has lost connection to the network element.

ddmi-infra

No action necessary.

DMI-3-CLI_ENGINE_EVENT_FAIL

3-Error

Failed to retrieve CLI engine event ([dec]): [chars].

DMI cannot retrieve its CLI engine event in order to interact with the network element CLI parser.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-CLI_ENGINE_LOG_LVL_FAIL

3-Error

Failed to set CLI engine logging level ([dec]): [chars].

DMI cannot set its CLI engine logging level.

ddmi-infra

Stop and restart DMI.

DMI-3-CLI_ENGINE_POLL_FAIL

3-Error

Failed to read CLI engine results - max polling attempts exceeded ([dec]).

DMI cannot read its CLI engine results in order to interact with the network element CLI parser.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration. If problem continues, stop and restart netconf-yang

DMI-3-CLI_ENGINE_READ_EVENT_FAIL

3-Error

Failed to read CLI engine event ([dec]): [chars].

DMI cannot read its CLI engine event in order to interact with the network element CLI parser.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration. If problem continues, stop and restart netconf-yang

DMI-3-CLI_ENGINE_READ_FAIL

3-Error

Failed to read CLI engine results ([dec]): [chars].

DMI cannot read its CLI engine results in order to interact with the network element CLI parser.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-CLI_ENGINE_RECONNECT_FAIL

3-Error

Error reconnecting to the network element ([dec]): [chars]

The CLI engine has lost its connection to the network element and attempted to reconnect with an error occurred.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-CLI_ENGINE_TOKEN_RETRY

3-Error

CLI engine authentication token is not available, retry for [dec] seconds

When IOSP-client connects to IOSP-server, it is authenticated by a session authentication token. The token is not available yet. Retry is made to retrieve the token.

ddmi-infra

None required

DMI-3-CLI_ENGINE_VTY_CREATE_FAIL

3-Error

The CLI engine failed to create a VTY instance ([dec]): [chars]

The DMI CLI engine cannot create a VTY instance.

ddmi-infra

Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

DMI-3-CLI_ENGINE_VTY_OPEN_FAIL

3-Error

The CLI engine failed to open a VTY ([dec]): [chars]

The DMI CLI engine cannot open a VTY.

ddmi-infra

Free up available VTY resources by closing unused VTYs. Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration. If problem continues, stop and restart netconf-yang

DMI-3-CLI_ENGINE_VTY_TIMEOUT_FAIL

3-Error

The DMI CLI engine failed to disable the VTY timeout ([dec]): [chars]

DMI disables the VTY timeout for the network element synchronizer's VTY connection to ensure its number cannot be silently claimed by other VTY sessions.

ddmi-infra

None required

DMI-3-CLI_ENGINE_WRITE_FAIL

3-Error

Error writing the CLI: [chars] - [chars]

A CLI engine error occurred while send a command line to the network element's CLI parser

ddmi-infra

Enter the command line in question manually via the network element's console or vty. If successful, stop and restart netconf-yang and retry.

DMI-3-CLI_GEN_FAIL

3-Error

Failed to generate CLI change set [chars] ([dec]): [chars].

A Confd error has occurred when requesting the CLI change set for a transaction.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-DIFF_FAIL

3-Error

Error saving diff file: [chars]/[chars] - [chars]

An operating system error occurred while performing a diff of two files and redirecting to a third file.

ddmi-infra

Check free space on device. Clean up if necessary. Also, reducing the value of max-diag-messages-saved in the cisco-ia model may help.

DMI-3-DIR_EXISTS

3-Error

Message diagnostics directory '[chars]' exists, but is not a directory.

A existing file is conflicting with a directory name.

ddmi-infra

Remove or rename the offending file.

DMI-3-EDIT_REJECTED

3-Error

The NETCONF running datastore edit request from application [chars], user [chars], via [chars] was recieved while a synchronization from the device running-configuration to the NETCONF running datastore was in progress. The edit request was rejected. Resend the edit request when the running-configuration synchronization has completed.

A NETCONF running datastore edit request occurred simultaneously with a database synchronization operation. Thus, the request has been rejected.

ddmi-infra

Retry the NETCONF edit again later.

DMI-3-INIT_SYNC_FAIL

3-Error

Initial DMI sync failed.

DMI failed to synchronize the network element's running configuration with the DMI data store upon DMI startup.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-INTERNAL_ERROR

3-Error

Internal error - [chars] [dec]: [chars]

An unexpected internal error has occurred.

ddmi-infra

Consult man page for impacted area to interpret the error code and string.

DMI-3-INVALID_PRESERVE_PATH

3-Error

The NED preserve path specified |[chars]| does not exist. Please remove from the /native/cisco-ia/preserve-ned-path list.

A non-existent XPath has been specified to be preserved during complete syncs.

ddmi-infra

Remove the offending path from the /native/cisco-ia/preserve-ned-path list.

DMI-3-INVALID_REG_EXP

3-Error

The regular expression |[chars]| is invalid. Please remove from the '[chars]' model or via the CLI '[chars] [chars]'

An invalid regular expression has been specified which will not compile.

ddmi-infra

Remove the offending regular expression from the specified model or via "no CLI".

DMI-3-LOAD_SCHEMAS_FAIL

3-Error

Cannot load Confd schemas [chars] ([dec]): [chars].

DMI failed to load Confd schemas for yang model namespaces.

ddmi-infra

Back out any recent yang model updates. Stop and restart netconf-yang.

DMI-3-MAAPI_APPLY_TRANS_FAIL

3-Error

Failed to apply a transaction via DMI MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to apply a transaction via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_DELETE_FAIL

3-Error

Failed to delete model path '[chars]' via DMI MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to delete a model path via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_FINISH_TRANS_FAIL

3-Error

Failed to finish a transaction via DMI MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to finish a transaction via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_KILL_SESSION_FAIL

3-Error

Could not kill DMI MAAPI user session [dec] - [chars] ([dec]): [chars].

A parser lock timeout has occurred, and DMI attempted to kill the session holding the global lock, but failed.

ddmi-infra

Kill the NETCONF user session holding the global lock manually.

DMI-3-MAAPI_LOAD_FAIL

3-Error

Failed to load '[chars]' commands to model path '[chars]' via DMI MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to load commands to a model path via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_LOAD_FILE_FAIL

3-Error

Failed to load file '[chars]' via DMI MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to load commands from a file via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_LOCK_FAIL

3-Error

Failed to lock the DMI data store via DMI MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to lock the DMI data store via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_SAVE_FAIL

3-Error

Could not save model path '[chars]' to file via DMI MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to save a model path via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_START_TRANS_FAIL

3-Error

Could not start DMI MAAPI transaction [chars] ([dec]): [chars].

A Confd error has occurred attempting to start a transaction via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_START_USER_FAIL

3-Error

Could not start DMI MAAPI user session [chars] ([dec]): [chars].

A Confd error has occurred attempting to start a user session via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MAAPI_UNLOCK_FAIL

3-Error

Failed to unlock the NETCONF running data store via MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to unlock the DMI data store via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-MEM_UNAVAIL

3-Error

Memory was not available to perform the DMI action.

Insufficient system memory is available to perform the DMI action.

ddmi-infra

Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

DMI-3-MODEL_RESTORE_FAIL

3-Error

DMI failed to restore the model '[chars]' from the network element's running configuration to the DMI data store ([dec]): [chars].

DMI failed to restore the model '%s' from the network element's running configuration to the DMI data store.

ddmi-infra

Check the netconf-yang section of the network element's running configuration. If populated with non-default values, stop and restart netconf-yang. If problem continues, restore the model's configuration in question via Netconf

DMI-3-NETCONF_KILL_SESSION

3-Error

NETCONF session [dec] has held a parser configuration lock/NETCONF datastore global lock for the maximum time allowed and has been killed.

A parser lock timeout has occurred, and DMI has killed the corresponding NETCONF session.

ddmi-infra

Establish a new NETCONF session. Adjust your application to hold global locks for a shorter interval -- seconds, not minutes

DMI-3-NETCONF_SSH_ERROR

3-Error

NETCONF/SSH: [chars]

An error message from the NETCONF SSH daemon.

ddmi-infra

Not applicable

DMI-3-SAVE_FAIL

3-Error

Error saving file: [chars] - [chars]

An operating system error occurred while opening or writing to a diagnostic file.

ddmi-infra

Check free space on device. Clean up if necessary. Also, reducing the value of max-diag-messages-saved in the cisco-ia model may help.

DMI-3-SYNC_CLI_FILTER_ADD_FAIL

3-Error

Failed to add CLI configuration monitor filter ([dec]): [chars].

DMI cannot add a CLI filter to monitor for external CLI changes.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-SYNC_CLI_FILTER_CREAT_FAIL

3-Error

Failed to create CLI configuration monitor filter for pattern '[chars]' ([dec]): [chars].

DMI cannot create a CLI filter to monitor for external CLI changes.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-SYNC_CLI_FILTER_MODE_FAIL

3-Error

Failed to set mode for CLI configuration monitor filter ([dec]): [chars].

DMI cannot set the mode for its CLI filter to monitor for external CLI changes.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-SYNC_ERR

3-Error

An attempt to synchronize the running configuration to the NETCONF running data store has failed: [chars]

An attempt to send the running-config to ConfD to repopulate its data store has failed.

ddmi-infra

Identify the offending CLI that makes the sync fail and delete it from the configuration.

DMI-3-SYNC_FAIL

3-Error

An attempt to synchronize the running configuration to the NETCONF running data store has failed.

An external change (outside of NETCONF or RESTCONF) has been detected. An attempt to send the running-config to Confd to repopulate its data store has failed.

ddmi-infra

Force a full sync via the 'sync-from' RPC.

DMI-3-SYNC_LOCK_FAIL

3-Error

Failed to lock the NETCONF running data store via MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to lock the DMI data store via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-SYNC_MODULE_CHECK_ADD_FAIL

3-Error

Failed to add module up check ([dec]): [chars].

DMI cannot add a module up check to monitor for module up status.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-SYNC_OIR_FILTER_ADD_FAIL

3-Error

Failed to add OIR monitor filter ([dec]): [chars].

DMI cannot add an OIR filter to monitor for OIR induced configuration changes.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-SYNC_OIR_FILTER_CREAT_FAIL

3-Error

Failed to create OIR monitor filter ([dec]): [chars].

DMI cannot create an OIR filter to monitor for OIR induced configuration changes.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-SYNC_SYSLOG_FILTER_ADD_FAIL

3-Error

Failed to add syslog monitor filter ([dec]): [chars].

DMI cannot add a syslog filter to monitor for external CLI changes.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-SYNC_SYSLOG_FILTER_CREAT_FAIL

3-Error

Failed to create syslog monitor filter for pattern '[chars]' ([dec]): [chars].

DMI cannot create a syslog filter to monitor for external CLI changes.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration.

DMI-3-SYNC_UNLOCK_FAIL

3-Error

Failed to unlock the NETCONF running data store via MAAPI [chars] ([dec]): [chars].

A Confd error has occurred attempting to unlock the DMI data store via MAAPI.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-VTY_NUM_FAIL

3-Error

DMI failed to retrieve its tty number from the network element

DMI must keep track of its tty number it uses to send command lines to the network element's parser in order to avoid triggering its own sync events

ddmi-infra

Check that the 'show users line' command line is working

DMI-3-VTY_SERVER_CREAT_FAIL

3-Error

Failed to create VTY server utility instance.

Failed to create VTY server utility instance for DMI operational data use.

ddmi-infra

Stop and restart netconf-yang.

DMI-3-VTY_SERVER_START_FAIL

3-Error

Failed to start VTY server utility instance.

Failed to start VTY server utility instance for DMI operational data use.

ddmi-infra

Stop and restart netconf-yang.

DMI-4-CANDIDATE_DATASTORE_DIRTY

4-Warning

Synchronization of the running configuration to the running datastore is deferred because the candidate datastore is dirty. Commit or discard the uncommitted configuration.

Configuration is performed from the IOS terminal while the candidate datastore has uncommitted configuration. The system cannot perform sync until the configuration in the datastore is either committed or discarded.

INVALID

Commit or discard the configuration in the candidate datastore in order for the sync to proceed.

DMI-4-CDB_MAINTENANCE_MODE

4-Warning

WARNING!!! - CDB MAINTENANCE MODE IS ACTIVE - [chars]. This mode is intended only for Cisco support - it must be disabled for normal NETCONF operation.

A Cisco-support only NETCONF mode has been enabled as a recovery mechanism for an out-of-sync condition.

ddmi-infra

Disable this mode in order to return the device to normal NETCONF operation.

DMI-4-CLI_ENGINE_ENABLE_FAIL

4-Warning

The DMI CLI engine failed to enable the network element's CLI parser (enter privileged mode) ([dec]): [chars]

DMI cannot enter privileged mode when communicating with the network element's CLI parser.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration. Check AAA settings for the Netconf/Restconf user account.

DMI-4-CLI_ENGINE_RC_FAIL

4-Warning

The DMI CLI engine failed to get the overall return code from the command '[chars]' ([dec]): [chars]

DMI cannot read CLI engine return code for the particular command.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration. If problem continues, stop and restart netconf-yang

DMI-4-CLI_ENGINE_STATE_FAIL

4-Warning

Failed to query the CLI engine state ([dec]): [chars]

DMI cannot read its CLI engine state.

ddmi-infra

Perform a manual sync operation to ensure the DMI data store is in sync with the network element's running configuration. If problem continues, stop and restart netconf-yang

DMI-4-CLI_LOCK_FAIL

4-Warning

Failed to obtain exclusive access to the IOS parser: [chars].

An IOS parser error has occurred attempting to obtain a configuration parser lock.

ddmi-infra

Retry NETCONF operation.

DMI-4-CLI_LOCK_OVERRIDE

4-Warning

Configuration lock cleared and obtained by NETCONF session.

An IOS parser lock has been cleared to avoid conflict with NETCONF session.

ddmi-infra

Retry CLI operation after NETCONF session completes.

DMI-4-CLI_ROLLBACK_WARN

4-Warning

CLI rollback warning: tid ([dec]): [chars].

A Confd induced CLI transaction was aborted and during the rollback CLIs, an error was returned

ddmi-infra

Confirm that the network element's running configuration is in the original state before the failed transaction

DMI-4-CLI_UNLOCK_FAIL

4-Warning

Failed to unlock the IOS parser store: [chars].

An IOS parser error has occurred attempting to unlock the parser lock.

ddmi-infra

Retry NETCONF operation.

DMI-4-CONFD_ROLLBACK_WARN

4-Warning

Error copying Confd rollback file ([dec]): [chars]

An error occurred saving the Confd rollback information.

ddmi-infra

Please enable rollback in Confd. Check for free file system space.

DMI-4-CONTROL_SOCKET_CLOSED

4-Warning

Confd control socket closed [chars] ([dec]): [chars].

The control socket connection to Confd has closed unexpectedly.

ddmi-infra

DMI will reset. No action necessary.

DMI-4-DIAG_WARN

4-Warning

Unable to prepare file system for message diagnostics.

An error occurred saving DMI message diagnostics.

ddmi-infra

Check for free file system space.

DMI-4-NETCONF_TRACE_WARN

4-Warning

Error copying netconf.trace.

An error occurred saving the Netconf trace information.

ddmi-infra

Please enable netconfTraceLog in Confd. Check for free file system space.

DMI-4-RUNNING_DATASTORE_VALID

4-Warning

Running datastore is valid.

Running datastore is valid after successful full-sync operation.

INVALID

Rollback configurations using rollback-files RPC to bring device into well known state.

DMI-4-SUB_READ_FAIL

4-Warning

Confd subscription socket read failed [chars] ([dec]): [chars].

A Confd error has occurred attempting to read the subscription socket.

ddmi-infra

DMI will reset. No action necessary.

DMI-5-ACTIVE

5-Notice

process is in steady state.

process is in steady state.

ddmi-infra

Informational only. No action required.

DMI-5-AUTHENTICATION_FAILED

5-Notice

Authentication failure from [chars]:[chars] for [chars] over [chars].

A user failed to authenticate.

ddmi-infra

No action is required.

DMI-5-AUTHORIZATION_FAILED

5-Notice

User '[chars]' from [chars]:[chars] was not authorized for [chars] over [chars].

A user was not authorized for the requested service.

ddmi-infra

No action is required.

DMI-5-AUTH_PASSED

5-Notice

User '[chars]' authenticated successfully from [chars]:[chars] for [chars] over [chars]. External groups: [chars]

A user authenticated successfully for a service.

ddmi-infra

No action is required.

DMI-5-CONFIG_I

5-Notice

Configured from [chars] by [chars], transaction-id [dec]

A change to the running configuration was performed using NETCONF or RESTCONF.

ddmi-infra

Informational only. No action required.

DMI-5-INITIALIZED

5-Notice

process has initialized.

process has initialized.

ddmi-infra

Informational only. No action required.

DMI-5-NACM_INIT

5-Notice

NACM configuration has been set to its initial configuration.

The running-config under the /nacm tree has been set to its initial configuration.

ddmi-infra

No action is required.

DMI-5-NACM_READRULES

5-Notice

NACM readrules for privilege level [dec] loaded successfully.

NACM rules to permit readonly access loaded successfully.

ddmi-infra

No action is required.

DMI-5-RESET

5-Notice

process internal state reset.

process internal state reset.

ddmi-infra

Informational only. No action required.

DMI-5-SYNC_COMPLETE

5-Notice

The running configuration has been synchronized to the NETCONF running data store.

An external change (outside of NETCONF or RESTCONF) has been detected; thus, the running-config has been sent to Confd to repopulate its data store.

ddmi-infra

Informational only. No action required.

DMI-5-SYNC_NEEDED

5-Notice

Configuration change requiring running configuration sync detected - '[chars]'. The running configuration will be synchronized to the NETCONF running data store.

A configuration change that may trigger additional changes has been detected; thus, the running-config will be sent to Confd to repopulate its data store.

ddmi-infra

Informational only. No action required.

DMI-5-SYNC_START

5-Notice

Synchronization of the running configuration to the NETCONF running data store has started.

An external change (outside of NETCONF or RESTCONF) has been detected; thus, the running-config will be sent to Confd to repopulate its data store.

ddmi-infra

Informational only. No action required.

DMI-6-NETCONF_SSH_INFO

6-Information

NETCONF/SSH: [chars]

An informational message from the NETCONF SSH daemon.

ddmi-infra

Not applicable

DMI-7-GEN_DEBUG

7-Debug

DMI DEBUG [chars] [chars]

A debug message for syslog consumption. For troubleshooting wihtout btrace

ddmi-infra

Not applicable

DOT11_LOG-3-CLIENT_DOT11_ERROR

3-Error

Error in [chars]

General Client Dot11 Error Message.

ewlc-client

LOG_STD_ACTION

DOT1X-3-PROC_START_ERR

3-Error

Dot1x unable to start.

The system failed to create the Dot1x process.

polaris-smd

Restart Dot1x process by entering <cmd>dot1x system-auth-control<cmd> command. If this message recurs, Reload the device.

DOT1X-3-UNKN_ERR

3-Error

An unknown operational error occurred.

The Dot1x process cannot operate due to an internal system error.

polaris-smd

Reload the device/process

DOT1X-4-INFO_EAPOL_PING_RESPONSE

4-Warning

The interface [chars] has an 802.1x capable client with MAC [chars]

An EAPOL ping was sent out on this port to determine 802.1x readiness of the client attached. An EAPOL response has been received by the device such as a PC.

polaris-smd

No action required.

DOT1X-4-MEM_UNAVAIL

4-Warning

Memory was not available to perform the 802.1X action. AuditSessionID [chars]

Insufficient system memory is available to perform the Dot1x Authentication.

polaris-smd

Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.

DOT1X-5-FAIL

5-Notice

Authentication failed for client ([chars]) with reason ([chars]) on Interface [chars] AuditSessionID [chars] [chars] [chars]

Dot1x authentication was unsuccessful.

polaris-smd

No action is required.

DOT1X-5-RESULT_OVERRIDE

5-Notice

Authentication result overridden for client ([chars]) on Interface [chars] AuditSessionID [chars]

Authentication result was overridden

polaris-smd

No action is required.

DOT1X-5-SUCCESS

5-Notice

Authentication successful for client ([chars]) on Interface [chars] AuditSessionID [chars] Username [chars]

Dot1x authentication was successful.

polaris-smd

No action is required.

DTLS_AUDIT_MESSAGE-6-FIPS_AUDIT_FCS_DTLSS_EXT_2_DTLS_REPLAY_ATTACK

6-Information

User ID: [chars] - DTLS Replay Attack for connection closed

DTLS Replay Attack for connection closed

ewlc-ap

LOG_STD_ACTION

DTLS_AUDIT_MESSAGE-6-FIPS_AUDIT_FCS_DTLSS_EXT_2_DTLS_REPLAY_ATTACK_DETECTED

6-Information

User ID: [chars] - DTLS Replay Attack detected for Source IP [chars] and Dest IP [chars]

DTLS Replay Attack detected for Source IP and Dest IP

ewlc-ap

LOG_STD_ACTION

DTLS_AUDIT_MESSAGE-6-FIPS_AUDIT_FPT_ITT_1_DTLS_SESSION_CLOSED

6-Information

User ID: [chars] - DTLS peer has closed the connection, cipher [chars]

DTLS connection established with peer

ewlc-ap

LOG_STD_ACTION

DTLS_AUDIT_MESSAGE-6-FIPS_AUDIT_FPT_ITT_1_DTLS_SESSION_ESTABLISHED

6-Information

User ID: [chars] - DTLS connection established with peer, cipher [chars]

DTLS connection established with peer

ewlc-ap

LOG_STD_ACTION

DTLS_AUDIT_MESSAGE-6-FIPS_AUDIT_FPT_ITT_1_DTLS_SESSION_HANDSHAKE_FAILURE

6-Information

User ID: [chars] - Failed to complete DTLS handshake with peer, reason: [chars]

Failed to complete DTLS handshake with peer

ewlc-ap

LOG_STD_ACTION

DTLS_TRACE_MSG-3-WLC_DTLS_ERR

3-Error

DTLS Error, [chars]

General ewlc Error Message.

ewlc-ap

LOG_STD_ACTION

DTLS_TRACE_MSG-3-X509_CERT_VERIFY_ERR

3-Error

Cert verify Error, [chars]

General ewlc Error Message.

ewlc-ap

LOG_STD_ACTION

EAP-2-PROCESS_ERR

2-Critical

EAP critical error [chars]

This is critical condition where the router could not perform EAP process related operation.

polaris-smd

Review SM logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log. Reload the device/process.

EAP-3-BADPKT

3-Error

IP=[chars] HOST=[chars]

This messages informs that the router received an invalid or malformed EAP packet from the specified host.

polaris-smd

Check specified host for EAP operation.

EAP-6-FIPS_UNSUPPORTED_METHOD

6-Information

Method [chars] in eap profile [chars] is not allowed in FIPS mode

This message informs that a method is not supported in FIPS mode.

polaris-smd

Use FIPS supported methods - PEAP, TLS and FAST

EAP-6-MPPE_KEY

6-Information

IP=[chars] MPPE_RECV_KEY_LENGTH=[dec]

This messages informs that the router received MPPE KEY for the specified host.

polaris-smd

No action is required.

EMD-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This error could be due to a software defect or system resource limitation.

iosxe-chassismgr

Restart the card.

EMD-0-RESOLVE_FRU

0-Emergency

Failed to determine [chars] card because [chars]

The system was unable to to determine a card state. This error could be due to a software defect or system resource limitation.

iosxe-chassismgr

Restart the card.

EMD-0-SERVICES_INITIALIZATION

0-Emergency

Failed to initialize general application services because [chars]

The system failed to initialize the application services. This error could be due to a software defect or system resource limitation.

iosxe-chassismgr

Restart the card.

EMD-3-IDPROM_ACCESS

3-Error

Failed access or process an IDPROM because [chars]

The system failed to access an IDPROM or an IDPROM process failed. This error can occur from a hardware defect, software defect, or incorrect IDPROM content.

iosxe-chassismgr

Examine the logs for IDPROM and hardware errors.

EMD-3-IDPROM_SENSOR

3-Error

One or more sensor fields from the idprom failed to parse properly because [chars].

One or more IDPROM sensor fields failed to parse properly. The most likely reason is a checksum failure in the IDPROM from incorrect IDPROM content.

iosxe-chassismgr

Examine the logs for IDPROM and hardware errors.

EMD-3-PFU_INITIALIZATION

3-Error

The RP has failed to initialize a Power Supply/Fan module controller because [chars]

The route processor (RP) failed to initialize a power supply or a fan module controller. This error could be caused by a hardware defect or a C2W access failure.

iosxe-chassismgr

Examine the logs for C2W and hardware errors.

EMD-3-SENSOR_INITIALIZATION

3-Error

Failed to initialize sensor monitoring because [chars].

The system failed to initialize an IDPROM sensor monitoring process. This error can occur from a hardware defect, software defect, or incorrect IDPROM content.

iosxe-chassismgr

Examine the logs for IDPROM and hardware errors.

EPM-4-ACL_CONFIG_ERROR

4-Warning

ACL NAME '[chars]' | ACE SEQUENCE [dec] | RESULT FAILURE | REASON [chars]

This message indicates that adding an ACE to the specified ACL was ignored because of wrong configuration

polaris-smd

Change ACE configuration for the specifed ACL

EPM-4-POLICY_APP_FAILURE

4-Warning

Policy Application Failed for Client [[chars]] MAC [[chars]] AuditSessionID [[chars]] for POLICY_TYPE [chars] POLICY_NAME [chars] REASON [chars]

This message indicates that the displayed policy for the client could not be applied by the EPM

polaris-smd

Policy application failure could happen due to multiple reasons.The reason for the failure is notified to the client and the client has to take appropriate action based on it

EPM-6-AAA

6-Information

POLICY [chars]| EVENT [chars]

This message indicates a download request has been sent/downloaded successfully for the specified dACL

polaris-smd

No action required

EPM-6-AUTH_ACL

6-Information

POLICY [chars]| EVENT [chars]

his message indicates a AUTH_DEF_ACL or AUTH_DEF_ACL_OPEN has been applied or removed

polaris-smd

No action required

EPM-6-IPEVENT

6-Information

IP [chars]| MAC [chars]| AuditSessionID [chars]| EVENT [chars]

This message indicates the IP event Wait/Release/Assignment that has occured with respect to the specified host

polaris-smd

No action required

EPM-6-POLICY_APP_SUCCESS

6-Information

Policy Application succeded for Client [[chars]] MAC [[chars]] AuditSession ID [[chars]] for POLICY_TYPE [[chars]] POLICY_NAME [[chars]]

This message indicates that the displayed policy for the client has been applied successfully by the EPM

polaris-smd

No action required

EPM-6-POLICY_REQ

6-Information

IP [chars]| MAC [chars]| AuditSessionID [chars]| EVENT [chars]

This message indicates that a policy application/remove request has been received by the EPM

polaris-smd

No action required

EPM_PLUGIN-5-ERR_HS20_URLFILTER_NOT_CONFIGURED

5-Notice

Attempt to enable url filtering for Hotspot 2.0 client [chars] without having an Hotspot 2.0 urlfilter configured

An attempt was made to activate post-auth Hotspot 2.0 url filtering on the client, as requested by the Radius server but no urlfilter list name configured under the wireless hotspot anqp-server linked with the wireless policy profile.

ewlc-spwifi

Make sure a valid urlfilter list name is configured under the wireless hotspot anqp-server profile linked with the wireless policy profile

EPM_PLUGIN-5-ERR_VLAN_NOT_FOUND

5-Notice

Attempt to assign non-existent or shutdown VLAN [chars] to 802.1x port [chars] AuditSessionID [chars]

An attempt was made to assign a VLAN to an 802.1x port, but the VLAN was not found in the VTP database.

polaris-smd

Make sure the VLAN exists and is not shutdown or use another VLAN.

EPM_PLUGIN-5-IGNORED_VLAN_VALIDATION

5-Notice

Vlan [chars] not defined on the controller, choosing Vlan [dec]

Either the client is export-foreign or fallback-vlan CLI is configured

polaris-smd

Check if fallback-vlan is configured or if the client is export foreign. In such a case, no action needs to be taken.

EPM_PLUGIN-5-PRINT_SEQUENCE

5-Notice

Creating ACE [dec] for ACL [chars]

Every 10000th ACE and its ACL name printed to indicate the ACEs being created.

polaris-smd

Please check that the ACE count matches the configured ACE count.

EPM_PLUGIN-5-VLAN_ASSIGN

5-Notice

Vlan assignment successful for client : [chars] with Vlan id : [dec] on Interface : [chars], AuditSessionID is [chars]

The syslog indicates that the Vlan was assigned to the client

polaris-smd

No action is required.

EPM_PLUGIN-6-STICKY_TIMER_START

6-Information

Sticky timer of [dec] seconds started for mac [chars] interface [chars] for template [chars]

Log is used to notify the start of the sticky timer

polaris-smd

Sticky timer has begun. No action needs to be taken.

EPOCH-6-EPOCH_REJECTED

6-Information

Peer [chars] has rejected epoch: [chars]

This error occurs if epoch from shell-manager has been rejected by the peer.

iosxe-shellmgr

Check the epoch and peer state.

EVUTIL-3-PERMISSION

3-Error

Operation not permitted for pid [dec] tid [dec]

Eventlib has detected that a process has attempted to invoke an API that is listed as having a level of permission.

iosxe-binos-utils

Review the process logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

EVUTIL-3-PREREQUISITE_INIT

3-Error

A preferred library has failed to initialize: [chars]

Eventlib has detected that a preferred library which provides infrastructure services has failed to fully initialize.

iosxe-binos-utils

Review the process logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

EVUTIL-6-PREREQUISITE

6-Information

Preferred library is absent

Eventlib has detected that a preferred library is missing from the process.

iosxe-binos-utils

This is an informational message.

EWLC_HA_LIB_MESSAGE-3-BULK_SYNC_STATE_ERR

3-Error

Error: Bulk sync status : [chars]

Bulk sync status Error message. TERMINATED - Bulk-sync terminated

ewlc-ha

LOG_STD_NO_ACTION

EWLC_HA_LIB_MESSAGE-3-WIRELESS_CONFIG_SYNC_FAIL

3-Error

Error: Wireless config sync not complete. Reloading the WLC!

Switchover happens before wireless config sync is complete!

ewlc-ha

LOG_STD_ACTION

EWLC_HA_LIB_MESSAGE-6-BULK_SYNC_STATE_INFO

6-Information

INFO: Bulk sync status : [chars]

Bulk sync status INFO message. COLD - Bulk-sync ongoing. CONFIG_DONE - critical DB sync complete. WARM - Most of the DB's synced. HOT - Bulk-sync completed

ewlc-ha

LOG_STD_NO_ACTION

EWLC_INFRA_MESSAGE-3-EWLC_EVENTHOG

3-Error

Event name: [chars]

System has detected an excessive number of sub-events. Normal WLC functionality may be impacted.

ewlc-app-infra

LOG_STD_ACTION

EWLC_INFRA_MESSAGE-3-EWLC_GEN_ERR

3-Error

Error in [chars]

General ewlc Error Message.

iosxe-binos-utils

LOG_STD_ACTION

EWLC_INFRA_MESSAGE-4-EWLC_CAC_WARNING_MSG

4-Warning

CPU Utilization [chars]

CPU utilisation for the process has breached the monitored level, some functionality may be impacted. If the condition persists, action may be needed.

ewlc-ap

If the condition is transient and does not occur frequently, these messages can be ignored otherwise an investigation is needed. LOG_STD_ACTION

EWLC_INFRA_MESSAGE-6-EWLC_CAC_INFO

6-Information

CPU Utilization [chars]

CPU Utilisation for the process has recovered below the monitored level

ewlc-ap

LOG_STD_NO_ACTION

EWLC_UTILITY_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_1_WPA2_INPUT_TOO_LARGE

3-Error

User ID: [chars] - Failed to compute PRF mode ([dec]), size ([dec]) - input is too large

Failed to compute PRF mode because of input is too large

iosxe-binos-utils

LOG_STD_RECUR_ACTION

EWLC_UTILITY_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_1_WPA2_INVALID_MODE

3-Error

User ID: [chars] - Failed to compute PRF mode ([dec]), size ([dec]) - invalid mode

Failed to compute PRF mode because of invalid mode

iosxe-binos-utils

LOG_STD_RECUR_ACTION

EWLC_UTILITY_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_CKM_1_WPA2_OUTPUT_BUFFER_SMALL

3-Error

User ID: [chars] - Failed to compute PRF mode ([dec]), size ([dec]) - output buffer is too small

Failed to compute PRF mode because of output buffer is too small

iosxe-binos-utils

LOG_STD_RECUR_ACTION

EZMAN_CLIENT-2-ECC_DOUBLE_BIT_ERROR

2-Critical

Double bit ECC errors observed. NP (CC card) is going to be reloaded to recover

ECC error observed on the NP device.Reset the NP Device.

asr1k-ether-lc

This error is usually self-correcting. If the problem persists, the CC card/hardware may need to be replaced.

EZMAN_CLIENT-3-ECC_SINGLE_BIT_ERROR

3-Error

Single bit ECC error

ECC error observed on the NP device.Reset the NP Device.

asr1k-ether-lc

This error is usually self-correcting. If the problem persists, the MIP100 hardware may need to be replaced.

EZMAN_CLIENT-3-OBJECT_FAIL

3-Error

Failed to bringup [chars]. Failure reason is [chars]

Bringup of object(NP/Bay/Interface) has failed in EZMAN. This can be due to any hardware/software failures and can be a serious error

asr1k-ether-lc

Restart the Linecard.

EZMAN_CLIENT-3-VLAN_STATS_ERR

3-Error

NP Counter Read Failed for Vlan [dec] [dec]

NP VLAN statistics error.

asr1k-ether-lc

Continous MSG of these Events, Trigger the reboot of the system

EZMAN_CLIENT-5-EZ_CLIENT_VLAN_FULL

5-Notice

TCAM Full VLAN is not Able to add

Rx Sync Failed for Interlaken, Status Timer Expired. So, Resetting the Rx Interlaken Core

asr1k-ether-lc

No user action is required.

EZMAN_INFRA-3-PLATFORM_ID_ERR

3-Error

Invalid HW Part number([dec]) and HW Revision([dec])

HW Part number and revision read from the IDPROM are not showing up expected values which means the IDPROM is either corrupted or incorrectly programmed.

asr1k-ether-lc

Possible Hardware issue. Change the hardware.

EZMAN_RM-2-FPGA_VERSION_CHECK_ERR

2-Critical

CASTOR FPGA[[dec]] version does not meet minimum required version. Read version : 0x%x, Min Req Version : 0x%x

Castor FPGA version requirement not met.

asr1k-ether-lc

Copy the message exactly as it appears on the console or in the system log, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

EZMAN_RM-2-SEM_ERR

2-Critical

CASTOR FPGA[[dec]] - SEU event has occurred. Event code: [dec], SLR: 0x%x, Frame: 0x%x, Word, 0x%x, Bit: 0x%x

A Single Event Upset (SEU) event has occurred. These events may occur at any point of time, but are considered to be rare.

asr1k-ether-lc

If the error is seen only once, there is no need for anything to be done. If these errors are appearing continuously/persistently, please copy over the logs as they appear in the console, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

EZMAN_RM-3-L2_BLOCK_EVENT

3-Error

L2 Block Event Node:[chars] (0x%08X - Tree [dec] Instance [dec])

NP of L2 is generating Events.

asr1k-ether-lc

Continous MSG of these Events, Trigger the reboot of the system

EZMAN_RM-3-SERDES_AUTOTUNE_FAIL

3-Error

Serdes Autotune [chars] on lane [dec]

NP5 Serdes RX is unable to autotune to the peer device's TX. This is a physical layer issue between NP5 and peer device.

asr1k-ether-lc

OIR the Host-card if possible.

F to J

Facility-Severity-Mnemonic

Severity-Meaning

Message

Message-Explanation

Component

Recommended-Action

FED-0-HWSTALL

0-Emergency

ASIC [dec] CORE [dec] Packet Buffer Complex Stalled. Switch will be reloaded\n

The specified asic/core packet buffer complex stalled. This is a critical error. This switch will reload. If there is a redundant switch, switch over will happen

polaris-platform_mgr

No action is required

FED-2-INIT_FAILED

2-Critical

Module [chars] failed initialization\n[chars]

The specified module failed initialization. The switch will reload.

polaris-platform_mgr

No action is required

FED3_EPC_ERRMSG-4-UNSUPPORTED

4-Warning

EPC on interface [chars] is not supported.To recover, Stop the capture.\n

Unsupported configuration.

INVALID

Stop the capture on %s interface.\n

FED3_L3M_SYS_MSG-3-RSRC_IPv4_ERR

3-Error

Failed to allocate the hardware resource for ipv4 multicast entry. Use \'show platform software fed [switch] <module> ip multicast retry mroute\' for details.

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED3_L3M_SYS_MSG-3-RSRC_IPv6_ERR

3-Error

Failed to allocate the hardware resource for ipv6 multicast entry. Use \'show platform software fed [switch] <module> ipv6 multicast retry mroute\' for details.

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED3_L3M_SYS_MSG-6-RSRC_Recovered

6-Information

Failed Multicast hardware resources recovered. Multicast replication will be operational again.

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED3_L3_ERRMSG-3-L3_FIB_OUT_OF_RESOURCE

3-Error

Failed to program [chars] fib [chars]/[dec] in NPU due to out of resource\n

Running out of Hardware resource to support the scale of this L3 FIB feature.

INVALID

Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform software fed active ip/ipv6 route summary

FED3_L3_ERRMSG-3-L3_PORT_OUT_OF_RESOURCE

3-Error

Failed to program port [chars] in NPU due to out of resource\n

Running out of Hardware resource to support the scale of the L3 Port feature.

INVALID

Verify supported scale for the platform from sdm and reduce the L3 Port scale accordingly. Capture show platform hardware fed active fwd-asic resource utilization

FED3_L3_ERRMSG-3-UNSUPPORTED_ACTION

3-Error

ERROR:[chars] Additionally, please remove this command from the interface config mode.\n

The specified action is not supported on this platform.

INVALID

Find out more about this unsupported functionality from the release documents and remove the command from the interface config mode

FED3_L3_ERRMSG-6-ADVISORY_NOTICE

6-Information

Advisory Notice: [chars] \n

This message is to bring attention to the user about certain capabilities and limitations of a feature.

INVALID

No action is needed. Please be mindful of the limitations.

FED3_MPLS_ERRMSG-3-mpls_unsupported_feature

3-Error

Unsupported feature. Failed to program. [chars] in software or hardware\n

The feature is not yet supported.

INVALID

Find out more about this unsupported feature from the release documents and remove the command from the interface config mode

FED3_MPLS_ERRMSG-4-MPLS_L2VPN_ATOM_DISP_PAUSE

4-Warning

Critical limit reached for [chars] resource. MPLS L2VPN ATOM_DISP Create PAUSED.\n

MPLS L2VPN ATOM DISP creations are paused as needed resources(mentioned in error message) are not available so new entries can not be programmed in HW.

INVALID

Find out from error messages about the resources that are not available. Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls routes summary, tcam utiliztion and resource utilization

FED3_MPLS_ERRMSG-4-MPLS_L2VPN_ATOM_IMP_PAUSE

4-Warning

Critical limit reached for [chars] resource. MPLS L2VPN ATOM_IMP Create PAUSED.\n

MPLS L2VPN ATOM IMP creations are paused as needed resources(mentioned in error message) are not available so new entries can not be programmed in HW.

INVALID

Find out from error messages about the resources that are not available. Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls routes summary, tcam utiliztion and resource utilization

FED3_MPLS_ERRMSG-4-MPLS_L2VPN_XCON_AC_PAUSE

4-Warning

Critical limit reached for [chars] resource. MPLS L2VPN XCON_AC Create PAUSED.\n

MPLS L2VPN XCON_AC creations are paused as needed resources(mentioned in error message) are not available so new entries can not be programmed in HW.

INVALID

Find out from error messages about the resources that are not available. Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls routes summary, tcam utiliztion and resource utilization

FED3_MPLS_ERRMSG-4-MPLS_LABEL_PAUSE

4-Warning

Critical limit reached for [chars] resource. MPLS Label Create PAUSED.\n

MPLS Label OCE creations are paused as needed resources(mentioned in error message) are not available so new entries can not be programmed in HW.

INVALID

Find out from error messages about the resources that are not available. Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls routes summary, tcam utiliztion and resource utilization

FED3_MPLS_ERRMSG-4-MPLS_LENTRY_PAUSE

4-Warning

Critical limit reached for [chars] resource. Lentry Create PAUSED.\n

MPLS Lentry creations are paused as needed resources(mentioned in error message) are not available so new label entries can not be programmed in HW.

INVALID

Find out from error messages about the resources that are not available. Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls summary, tcam utiliztion and resource utilization

FED3_MPLS_ERRMSG-4-mpls_out_of_resource

4-Warning

Out of resource for MPLS [chars]. Failed to program [chars] in hardware\n

Running out of Hardware resource to support the scale of this MPLS feature.

INVALID

Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls summary, tcam utiliztion and resource utilization

FED3_MPLS_ERRMSG-6-MPLS_L2VPN_ATOM_DISP_RESUME

6-Information

[chars] resources are now available. MPLS L2VPN ATOM_DISP Create RESUMED.\n

MPLS L2VPN ATOM DISP creations are resumed. Now new entries can be programmed in HW.

INVALID

No action needs to be taken.

FED3_MPLS_ERRMSG-6-MPLS_L2VPN_ATOM_IMP_RESUME

6-Information

[chars] resources are now available. MPLS L2VPN ATOM_IMP Create RESUMED.\n

MPLS L2VPN ATOM IMP creations are resumed. Now new entries can be programmed in HW.

INVALID

No action needs to be taken.

FED3_MPLS_ERRMSG-6-MPLS_L2VPN_XCON_AC_RESUME

6-Information

[chars] resources are now available. MPLS L2VPN XCON_AC Create RESUMED.\n

MPLS L2VPN XCON_AC creations are resumed. Now new entries can be programmed in HW.

INVALID

No action needs to be taken.

FED3_MPLS_ERRMSG-6-MPLS_LABEL_RESUME

6-Information

[chars] resources are now available. MPLS Label Create RESUMED.\n

MPLS Label creations are resumed. Now new entries can be programmed in HW.

INVALID

No action needs to be taken.

FED3_MPLS_ERRMSG-6-MPLS_LENTRY_RESUME

6-Information

[chars] resources are now available. Lentry Create RESUMED.\n

MPLS Label entries creations are resumed. Now new label entries can be programmed in HW.

INVALID

No action needs to be taken.

FED3_PUNJECT-6-PKT_CAPTURE_FULL

6-Information

Punject pkt capture buffer is full. Use show command to display the punted packets.\n

All the available punt capture buffers have been written with punted packets.

INVALID

No action is needed.

FED3_PUNJECT_CLI-6-EPDA_NPU_TRAPS_DEBUGGING_WARNING

6-Information

Warning: Please note traps enabled in Enhanced Packet Drop Analyzer (EPDA) will share the counters in Enhanced Drop Detection(EDD) CLI. This will result in showing the same counter values for the trap(s) in EDD\n

When EPDA is enabled the counters will be shared by EDD while displaying EDD counters

INVALID

No action is needed.

FED3_PUNJECT_CLI-6-EPDA_TM_TRAPS_DEBUGGING_WARNING

6-Information

Warning: Enabling TM traps will affect Per VOQ counters. Please clear TM traps once drop-capture is completed\n

Enabling TM traps will affect per voq counters

INVALID

No action is needed.

FED3_QOS_ERRMSG-3-FED3_SERVICE_POLICY_FAILED

3-Error

Failed to apply service-policy.\n

An error occurred during service-policy installation in FED.

pangea-qos

Need to find the info from logs. Use "sh platform software trace message fed active" to find the logs

FED3_QOS_ERRMSG-3-FED3_SERVICE_POLICY_FAILED_PREVIOUSLY

3-Error

The policy [chars] on interface [chars] on [chars] direction is already in ERROR state. No action will be taken.\n

There was an error occured early. No further action is taken until the policy removed and reattached.

pangea-qos

Remove the policy from the interface and reattach.

FED3_VLAN_MAPPING_ERRMSG-3-MAPPING_HW_ERROR

3-Error

Failed to update VLAN_MAPPING in hardware for interface [chars].\n

An error occurs when mapping VLAN.

polaris-l2

The resource limit would have been reached, remove the recent added vlan mapping configuration

FED3_VLAN_MAPPING_ERRMSG-3-VP_HW_ERROR

3-Error

Failed to add VP in hardware for interface [chars].\n

An error occurs when adding VP

polaris-l2

VP limit would have been reached, please remove the recent configuration

FED_CCK_ERRMSG-4-INCONSISTENCY_FOUND

4-Warning

Consistency Checker(CCK) detected inconsistency for [chars]. Check 'show consistency run-id [dec] detail'.

CCK has detected the inconsistency between the IOSD and fmanFP tables.

INVALID

Find out the entry using the show consistency <> command

FED_COND_DEBUG-6-COND_DEBUG_BOTH_V4_V6_ADDR_SET

6-Information

Failed to start, both v4 & v6 addr is set

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_INVALID_IN_FILE

6-Information

Failed to start, invalid file, not found

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_INVALID_PORT

6-Information

Failed to start, invalid Port, not found

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_INVALID_SWITCH

6-Information

Failed to start, invalid Switch, not found

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_MAC_NOT_SET

6-Information

Failed to start, for simulation packet generation src/dst mac is must

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_MEMORY_ALLOC_FAIL

6-Information

Failed to start, memory allocation failed

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_MULTIPLE_ACES

6-Information

Multiple entries found in provided ACL, common fields will get overlapped by later entries

Warning for acl having multiple aces

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_NETWROK_PREFIX_NOT_SUPPORTED

6-Information

Failed to start, simulation needs full address, netwrok prefix not supported

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_SRC_AND_DST_ADDR_NOT_SET

6-Information

Failed to start, both src and dst addr is required

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_COND_DEBUG-6-COND_DEBUG_START_FAIL

6-Information

Failed to start trace

Packet trace failed to start

polaris-platform_mgr

No action is required

FED_FNF_ERRMSG-3-ADVBASEATTACHERROR

3-Error

Unable to attach flow monitor or IP NBAR/Et-analytics to interface [chars]. Flow monitor and IP NBAR/Et-analytics are not allowed on the same interface.

The requested configuration is not allowed.

polaris-platform_mgr

Please try to modify your configuration.

FED_FNF_ERRMSG-3-ATTACHERROR

3-Error

Failed to attach flow monitor to interface [chars].\n

An error occurs when attaching the flow monitor to the interface.

polaris-platform_mgr

Find out more about the error by using show mgmt-infra trace messages fed-fnf-config-error switch number command

FED_FNF_ERRMSG-3-DETACHERROR

3-Error

Failed to detach flow monitor from interface [chars]\n

Error occurs when detaching the flow monitor from the interface.

polaris-platform_mgr

Find out more about the error by using show mgmt-infra trace messages fed-fnf-config-error switch number command

FED_FNF_ERRMSG-3-FLOWMONITOR_ENABLEERROR

3-Error

'[chars]' enablement failed due to '[chars]' configuration present on interface [chars]. These features cannot co-exist.

The requested configuration is not allowed.

polaris-platform_mgr

Please try to modify your configuration.

FED_FNF_ERRMSG-3-REFMONITOR_ENABLEERROR

3-Error

Failed to enable [chars] [chars] Reflexive ACL on [chars] and traffic will be dropped; '[chars]' configuration present on interface.

The requested configuration is not allowed.

polaris-platform_mgr

Please try to modify your configuration.

FED_FNF_ERRMSG-3-REFMONITOR_FAILED

3-Error

Failed to enable [chars] [chars] Reflexive ACL on [chars] and traffic will be dropped; Netflow programming failed.

The requested configuration failed; traffic will be dropped on this interface.

polaris-platform_mgr

Find out more about the error with the help of FED logs

FED_FNF_ERRMSG-3-REFMONITOR_RSCFULL

3-Error

Failed to enable [chars] [chars] Reflexive ACL on [chars] and traffic will be dropped; Netflow profiles exhausted.

The requested configuration failed; traffic will be dropped on this interface.

polaris-platform_mgr

Remove the existing FNF/FNF based feature attachment and retry

FED_FNF_ERRMSG-3-SGTCATTACHERROR

3-Error

Detach the existing [chars] before attaching [chars] to interface [chars]. These features cannot co-exist.

The requested configuration is not allowed.

polaris-platform_mgr

Please try to modify your configuration.

FED_FNF_ERRMSG-6-NOTALLOWED

6-Information

[chars] is not allowed.\n

The requested configuration is not allowed.

polaris-platform_mgr

Please try to modify your configuration.

FED_FNF_ERRMSG-6-UNSUPPORTED

6-Information

[chars] is unsupported\n

The requested configuration is not supported.

polaris-platform_mgr

Please do not use the current configuration.

FED_IPC_MSG-5-FAST_RELOAD_COMPLETE

5-Notice

Fast reload operation complete

This is used to indicate that the fast reload is complete.

accsw-p-fsu

No action needed. This is not an error.

FED_IPC_MSG-5-xFSU_COMPLETE

5-Notice

Fast reload operation complete

This is used to indicate that the fast reload is complete.

accsw-p-fsu

No action needed. This is not an error.

FED_IPC_MSG-5-xFSU_NIF_DISABLE_START_TIME

5-Notice

NIF was DISABLED at [chars]

XFSU NIF Disable Timestamp

accsw-p-fsu

No action needed. This is not an error.

FED_IPC_MSG-5-xFSU_NIF_ENABLE_START_TIME

5-Notice

NIF was ENABLED at [chars]

XFSU NIF ENABLE Timestamp

accsw-p-fsu

No action needed. This is not an error.

FED_IPC_MSG-5-xFSU_NIF_UPGRADE_TIME

5-Notice

NIF UPGRADE took [dec] milliseconds

XFSU NIF UPGRADE Time

accsw-p-fsu

No action needed. This is not an error.

FED_L2M_ERRMSG-3-COLLISION_LIST_RSRC_ERR

3-Error

Failed to allocate hardware resource for group [chars] - reason: [chars] - entry collided with groups: [chars] in hash

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L2M_ERRMSG-3-RSRC_ERR

3-Error

Failed to allocate hardware resource for group [chars] - resource type: [chars] - reason: [chars]

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L2M_ERRMSG-3-VLAN_RSRC_ERR

3-Error

Failed to allocate hardware resource for vlan [dec] - resource type: [chars] - reason: [chars]

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3M_ERRMSG-3-RSRC_ERR

3-Error

Failed to allocate hardware resource for [chars] - rc:[chars]

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3M_ERRMSG-4-lsm_LB_warning

4-Warning

IGP load balance not supported for Label Switch Multicast. Configure 'no mpls mldp forward recursive' to disable

MPLS IGP load balance/ECMP is not supported. Entries will be put into retry and once user disables the ECMP via CLI, LSM will recover

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3M_ERRMSG-4-lsm_RSRC_ERR

4-Warning

Failed to allocate the hardware resource for LSM(Label Switch multicast) entry, LSM replication will be impacted

Hardware resource allocation has failed and the entry will not be programmed. Entry will be in retry queue waiting for resources, once available LSM will recover

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3M_ERRMSG-4-lsm_label_warning

4-Warning

MPLS label range from [dec] to [dec] is not supported with Label Switch Multicast (LSM). Reconfigure 'mpls label range' accordingly.

MPLS range of upper 4k from 1M supported protocal value is reserved for LSM to use internally.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3M_ERRMSG-4-lspvif_RSRC_ERR

4-Warning

Failed to allocate the hardware resource for Lspvif Adjacency, some of the LSM MDTs will be impacted

Hardware resource allocation has failed and the entry will not be programmed. Entry will be in retry queue waiting for resources, once available LSM MDTs will recover

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3M_ERRMSG-6-lsm_RSRC_ERR_recovered

6-Information

Failed LSM hardware resources recovered. LSM replication will be operational again

Hardware resource failure is recovered again and LSM(Label Switch Multicast) will be back to normal

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3M_ERRMSG-6-lspvif_RSRC_ERR_recovered

6-Information

Retry of Lspvif Adjacency hardware resource(s) is(are) successful, LSM MDTs will be operational again

Hardware resource failure is recovered again and LSM(Label Switch Multicast) will be back to normal

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3_ERRMSG-3-L3_FIB_ENTRY_PAUSE

3-Error

Critical limit reached for [chars] resource. L3 FIB Entry Create PAUSED.\n

L3 FIB Entry creations are paused as needed resources(mentioned in error message) are not available so new entries can not be programmed in HW.

INVALID

Find out from error messages about the resources that are not available. Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for l3 routes summary, tcam utiliztion and resource utilization

FED_L3_ERRMSG-3-L3_FIB_ENTRY_RESUME

3-Error

[chars] resources are now available. L3 FIB Entry Create RESUMED.\n

L3 FIB Entry creations are resumed. Now new entries can be programmed in HW.

INVALID

No action needs to be taken.

FED_L3_ERRMSG-3-MAX_TUNNEL

3-Error

The maximum number of Tunnel has been reached\n

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

New Tunnels will not be working as expected.

FED_L3_ERRMSG-3-MPLS_LABEL_PAUSE

3-Error

Critical limit reached for [chars] resource. MPLS Label Create PAUSED.\n

MPLS Label OCE creations are paused as needed resources(mentioned in error message) are not available so new entries can not be programmed in HW.

INVALID

Find out from error messages about the resources that are not available. Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls routes summary, tcam utiliztion and resource utilization

FED_L3_ERRMSG-3-MPLS_LABEL_RESUME

3-Error

[chars] resources are now available. MPLS Label Create RESUMED.\n

MPLS Label creations are resumed. Now new entries can be programmed in HW.

INVALID

No action needs to be taken.

FED_L3_ERRMSG-3-MPLS_LENTRY_PAUSE

3-Error

Critical limit reached for [chars] resource. Lentry Create PAUSED.\n

MPLS Lentry creations are paused as needed resources(mentioned in error message) are not available so new label entries can not be programmed in HW.

INVALID

Find out from error messages about the resources that are not available. Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls summary, tcam utiliztion and resource utilization

FED_L3_ERRMSG-3-MPLS_LENTRY_RESUME

3-Error

[chars] resources are now available. Lentry Create RESUMED.\n

MPLS Label entries creations are resumed. Now new label entries can be programmed in HW.

INVALID

No action needs to be taken.

FED_L3_ERRMSG-3-RSRC_ERR

3-Error

Failed to allocate hardware resource for [chars] - rc:[dec]

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_L3_ERRMSG-3-RSRC_L3_LE_ERR

3-Error

Interface [chars] creation failed due to L3 Interface hardware resource exhaustion

Hardware resource for L3 Interface exhausted and the requested interface will not be created.

INVALID

Collect output of show platform hardware fed switch <switch number> fwd-asic resource utilization command. Check if RSC_L3IF_LE has exhausted. If yes, free up any unused L3 Interfaces by doing no interface <interface> and retry creating the failed interface.

FED_L3_ERRMSG-3-UNSUPPORTED_CMD

3-Error

[chars] is not supported on the interface [chars]\n

The specified cli is not yet supported.

INVALID

Find out more about this unsupported feature from the release documents and remove the command from the interface config mode

FED_L3_ERRMSG-3-ecr_err

3-Error

Platform unicast routing ecr module encountered [chars] error in FED\n

An error occurred in platform ecr code.

INVALID

Find out more about this error by using the show platform ipunicast ecr commands.

FED_L3_ERRMSG-3-fib_err

3-Error

Platform unicast routing fib module encountered [chars] error in FED\n

An error occurred in platform fib code.

INVALID

Find out more about this error by using the show platform ipunicast route commands.

FED_L3_ERRMSG-3-intf_err

3-Error

[chars] interface [chars]\n

Error in HW programming for Interface.

INVALID

Find out more about this failure from ifm show outputs and debugs for the interface

FED_L3_ERRMSG-3-mpls_ecmp_modify_err

3-Error

MPLS Load Balance modify is not supported [dec]\n

Modification of an ECMP object with MPLS Adjacencies is not supported yet. It is not an expected event

INVALID

Find out more about this error by using the show commands for the specified object and identify the possible trigger for the modify.

FED_L3_ERRMSG-3-mpls_out_of_resource

3-Error

Out of resource for MPLS [chars]. Failed to program [chars] in hardware\n

Running out of Hardware resource to support the scale of this MPLS feature.

INVALID

Verify supported scale for the platform from sdm and reduce the scale accordingly. Capture show platform command for mpls summary, tcam utiliztion and resource utilization

FED_L3_ERRMSG-3-mpls_recursive_label_err

3-Error

Unsupported recursive MPLS label for local_label [dec] [chars]\n

The specified MPLS local label is recursive and is not yet supported.

INVALID

Find out more about this error by using the show commands for the specified local_label and modify the config using LDP filters to remove recursive labels.

FED_L3_ERRMSG-3-mpls_unsupported_feature

3-Error

Unsupported feature. Failed to program. [chars] in software or hardware\n

The feature is not yet supported.

INVALID

Find out more about this unsupported feature from the release documents and remove the command from the interface config mode

FED_L3_ERRMSG-3-pbr_err

3-Error

Platform unicast routing pbr module encountered [chars] error in FED\n

An error occurred in platform pbr code.

INVALID

Find out more about this error by using the show platform ipunicast policy commands

FED_L3_ERRMSG-3-wccp_err

3-Error

Platform unicast routing wccp module encountered [chars] error in FED\n

An error occurred in platform wccp code.

INVALID

Find out more about this error by using the show platform ipunicast wccp commands.

FED_PM-3-FRU_SWITCH_TIMEOUT

3-Error

Transeiver update timed out. Remove and re-insert all FRUs in this switch to recover.\n

An FRU update event took too long to process on this switch. The FRUs on this switch may not be recoginized or function properly after this.

polaris-l2

Remove and re-insert all FRUs on this switch. The system should recognize and process them correctly after that.

FED_PM-3-FRU_TIMEOUT

3-Error

FRU module [dec] bringup timed out. Remove and re-insert it to recover.\n

The given FRU module in the switch in question could not be recognized because it took too long do so.

polaris-l2

Remove and re-insert the specified FRU module. The system should recognize it correctly after that.

FED_PM-3-FRU_TRANSCEIVER_TIMEOUT

3-Error

Transceiver event handling for interface [chars] timed out. Remove and re-insert the FRU module containing this interface to recover.\n

Than handling onf a transceiver event took too long for the given interface.

polaris-l2

Remove and re-insert the FRU module containing this interface. The system should recover from this failure condition after that.

FED_PM-3-HW_ERROR

3-Error

Port Manager error -[chars] hardware update failed.\n

An error occurred in Port Manager code.

polaris-l2

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_PM-3-RESRC_ERROR

3-Error

Port Manager error -[chars] resource access failed.\n

An error occurred in Port Manager code.

polaris-l2

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_PTP_ERRMSG-3-ATTACHERROR

3-Error

Failed to run PTP [chars].\n

An error occurs when running PTP.

polaris-platform_mgr

Find out more about the error by using show mgmt-infra trace messages fed-ptp-config-error switch number command

FED_PTP_ERRMSG-3-DETACHERROR

3-Error

Failed to run PTP [chars]\n

Error occurs when running PTP.

polaris-platform_mgr

Find out more about the error by using show mgmt-infra trace messages fed-ptp-config-error switch number command

FED_PTP_ERRMSG-6-NOTALLOWED

6-Information

[chars] is not allowed.\n

The requested configuration is not allowed.

polaris-platform_mgr

Please try to modify your configuration.

FED_PTP_ERRMSG-6-UNSUPPORTED

6-Information

[chars] is unsupported\n

The requested configuration is not supported.

polaris-platform_mgr

Please do not use the current configuration.

FED_PUNJECT-6-PKT_CAPTURE_FULL

6-Information

Punject pkt capture buffer is full. Use show command to display the punted packets.\n

All the available punt capture buffers have been written with punted packets.

INVALID

No action is needed.

FED_QOS_ERRMSG-3-AFD_POLICER_HW_ERROR

3-Error

Failed to [chars] for [chars].\n

An error occurred in programming the Approximate Fair Dropping policer.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-AFD_QUEUE_HW_ERROR

3-Error

Failed to program AFD [chars] virtual queue for [chars].\n

An error occurred in programming the Approximate Fair Dropping virtual queue.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-LABEL_2_QUEUE_MAPPING_HW_ERROR

3-Error

Failed to [chars] for [chars]: code [dec].\n

An error occurred in programming label to queue map.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-NETFLOW_TABLE_HW_ERROR

3-Error

Failed to program netflow entries for policy-map [chars] for client mac:[chars] iifid:0x%llx. code:[dec].\n

An error occurred in programming netflow table.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-POLICER_HW_ERROR

3-Error

Failed to [chars] for [chars]: code [dec].\n

An error occurred in programming the policer.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-POLICER_MAP_HW_ERROR

3-Error

Failed to [chars] for [chars]: code [dec].\n

An error occurred in programming the policer map.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-QUEUE_BUFFER_HW_ERROR

3-Error

Failed to [chars] for [chars]: code [dec].\n

An error occurred when programming the queue buffer.

INVALID

Find out more about the error by using the show tech-support priveleged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-QUEUE_SCHEDULER_HW_ERROR

3-Error

Failed to [chars] for [chars]: code [dec].\n

An error occurred when programming the queue scheduler.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-TABLEMAP_EGRESS_HW_ERROR

3-Error

Failed to [chars] for [chars]: code [dec].\n

An error occurred when programming egress table-map to hardware.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-TABLEMAP_INGRESS_HW_ERROR

3-Error

Failed to [chars] for [chars]: code [dec].\n

An error occurred when programming ingress table-map to hardware.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-3-TABLEMAP_INIT_ERROR

3-Error

Failed to initialize [chars].\n

An error occurred during table-map initialization.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

FED_QOS_ERRMSG-4-APPLICATION_ID_OVERFLOW

4-Warning

Failed to allocate application ID for policy-map [chars] on [chars].\n

The application IDs are exhausted.

INVALID

Reduce the number of applications to make application ID available.

FED_QOS_ERRMSG-4-CONFIGURE_PORT_TYPE_HW_ERROR

4-Warning

Failed to configure port [chars] as [chars] port in hardare. rc:[dec].\n

The port could not be configured in hardware

INVALID

Try to shutdown the port and then unshut the port

FED_QOS_ERRMSG-4-LABEL_2_QUEUE_MAPPING_OVERFLOW

4-Warning

Failed to [chars]. No more queue-maps are available.\n

The system supports up to 8 queue-maps. This limit has been reached.

INVALID

Unconfigure some of the queuing policies to make the resource available.

FED_QOS_ERRMSG-4-NETFLOW_TABLE_OVERFLOW

4-Warning

Failed to program netflow entries for policy-map [chars] for client mac:[chars] iifid:0x%llx. No netflow resource is available.\n

The netflow resources are exhausted.

INVALID

Unconfigure features to make the netflow resource available.

FED_QOS_ERRMSG-4-OUTPUT_ACS_CLIENT_POLICY_ERROR

4-Warning

Unsupported output client policy([chars]).\n

Unsupported policy.

INVALID

Unsupported client output policy

FED_QOS_ERRMSG-4-OUTPUT_CLIENT_POLICY_ERROR

4-Warning

Unsupported output client policy([chars]) - range operators.\n

Unsupported policy.

INVALID

Range operators are not supported in client output policy

FED_QOS_ERRMSG-4-POLICER_MAP_TABLE_OVERFLOW

4-Warning

Failed to [chars] for [chars]. No more policer map tables are available.\n

The ASIC supports up to 64 policer map tables. This limit has been reached.

INVALID

Unconfigure some policer maps to make the resource available.

FED_QOS_ERRMSG-4-POLICER_OVERFLOW

4-Warning

Failed to [chars] for [chars]. No policer resource is available.\n

The policer resource limit has been reached.

INVALID

Unconfigure some policers to make the resource available.

FED_QOS_ERRMSG-4-STACK_BUFFER_CONFIG_MGIG

4-Warning

Detected stack-buffer disable ([dec]), which is not a supported configuration for mGig platforms. Change to 'stack-buffer enable' configuration.\n

The stack-buffer configuration for an mGig switch should always remain as enabled.

INVALID

Change the configuration back as stack-buffer enable

FED_QOS_ERRMSG-4-TABLEMAP_OVERFLOW

4-Warning

Failed to attach [chars]. No more table-maps are available.\n

The system supports up to 16 table-maps per direction. This limit has been reached.

INVALID

Unconfigure some of the table-maps to make the resource available.

FED_QOS_ERRMSG-4-TCAM_OVERFLOW

4-Warning

Failed to program TCAM for policy-map [chars] on [chars].\n

The TCAM resources are exhausted.

INVALID

Unconfigure features to make TCAM resources available.

FED_ROT-4-VALIDATION_FAILURE

4-Warning

The RoT Validation for ASIC [dec] has failed because [chars]

The NPU RoT validation has failed. This could be due to a hardware or software defect. This is a critical error. NPU will stop forwarding traffic

polaris-platform_mgr

No action is required

FED_SPAN_ERRMSG-3-UNSUPPORTED_CONFIG

3-Error

SPAN configuration for source is not supported [chars] \n

A failure occurred in platform SPAN Source prgm

polaris-l2

This failure occurs with SPAN Src (port, Vlan) is part of a different SPAN session and is being reprogrammed again

FED_SPAN_ERRMSG-3-fspan_hw_update_err

3-Error

Platform FSPAN encountered an error in FED - [chars]\n

An error occurred in platform FSPAN code.

polaris-l2

Collect output of hardware tables/registers related to FSPAN and details of related ASIC resource handles.

FED_SPAN_ERRMSG-3-sess_rc

3-Error

Platform SPAN encountered an update error in FED - [chars], session [dec], return code [dec].\n

An error occurred in platform update SPAN code.

polaris-l2

Collect the output of debug platform monitor-fed while configuring SPAN or FSPAN.

FED_SPAN_ERRMSG-3-span_gen_hw_update_err

3-Error

Platform SPAN encountered an error in FED - [chars].\n

An error occurred in platform SPAN code.

polaris-l2

Collect the output of debug platform monitor-fed command while configuring SPAN or FSPAN.

FED_SPAN_ERRMSG-3-span_hw_update_err

3-Error

Platform SPAN encountered an error in FED - [chars]\n

An error occurred in platform SPAN code.

polaris-l2

Collect output of hardware tables and registers related to SPAN and details of related ASIC resource handles.

FED_SPAN_ERRMSG-3-span_stp_status_update_err

3-Error

Platform SPAN encountered an error in FED - [chars]\n

An error occurred in platform SPAN code for STP state updates in ASIC.

polaris-l2

Collect output of hardware tables and registers related to FSPAN and details of related ASIC resource handles.

FED_SRVO_ERRMSG-3-ATTACHERROR

3-Error

Failed to run SRVO [chars].\n

An error occurs when running SRVO.

polaris-platform_mgr

Find out more about the error by using show mgmt-infra trace messages fed-srvo-config-error switch number command

FED_SRVO_ERRMSG-3-DETACHERROR

3-Error

Failed to run SRVO [chars]\n

Error occurs when running SRVO.

polaris-platform_mgr

Find out more about the error by using show mgmt-infra trace messages fed-srvo-config-error switch number command

FED_SRVO_ERRMSG-6-NOTALLOWED

6-Information

[chars] is not allowed.\n

The requested configuration is not allowed.

polaris-platform_mgr

Please try to modify your configuration.

FED_SRVO_ERRMSG-6-UNSUPPORTED

6-Information

[chars] is unsupported\n

The requested configuration is not supported.

polaris-platform_mgr

Please do not use the current configuration.

FED_STATS-6-MEMORY_PARITY_ERR

6-Information

Detected memory parity errors on ASIC INST([dec])\n

Memory parity errors reached threshold.

iosxe-chassismgr

If this message occurs, customer needs to reach out to TAC. TAC will collect and review the output of \'show logging onboard switch active message detail\'. If there are so many single-parity memory errors (>=1000 in 24 hours). TAC may ask the switch to be reloaded or RMAed.

FED_STP_ERRMSG-3-MAX_INSTANCES

3-Error

The maximum number of STP instances has been reached:[dec]

The maximum number of STP instances that can be programmed has been reached.

INVALID

Delete or resolve loops manually for the vlans created further.

FED_VLAN_TRANSLATE_ERRMSG-3-ATTACHERROR

3-Error

Failed to run VLAN_TRANSLATE [chars].\n

An error occurs when running VLAN_TRANSLATE.

polaris-platform_mgr

Find out more about the error by using show mgmt-infra trace messages fed-vlan_translate-config-error switch number command

FED_VLAN_TRANSLATE_ERRMSG-3-DETACHERROR

3-Error

Failed to run VLAN_TRANSLATE [chars]\n

Error occurs when running VLAN_TRANSLATE.

polaris-platform_mgr

Find out more about the error by using show mgmt-infra trace messages fed-vlan_translate-config-error switch number command

FED_VLAN_TRANSLATE_ERRMSG-6-NOTALLOWED

6-Information

[chars] is not allowed.\n

The requested configuration is not allowed.

polaris-platform_mgr

Please try to modify your configuration.

FED_VLAN_TRANSLATE_ERRMSG-6-UNSUPPORTED

6-Information

[chars] is unsupported\n

The requested configuration is not supported.

polaris-platform_mgr

Please do not use the current configuration.

FED_XCVR_MSG-3-BO_FAILED

3-Error

[dec] [dec] break out failed

New BO command might have entered too fast or Deactivation taking time to clean feature objects

polaris-l2

Likely IOS and FED might be out of state, reload to use BO ports

FED_XCVR_MSG-3-BO_NOT_FINISHED

3-Error

[dec] [dec] previous breakout command not yet finished, wait for completion message

New BO command might have entered too fast or Deactivation taking time to clean feature objects

polaris-l2

Likely IOS and FED might be out of state, reload to use BO ports

FED_XCVR_MSG-3-BO_SUCCESSFUL

3-Error

[dec] [dec] break out successful

New BO command might have entered too fast or Deactivation taking time to clean feature objects

polaris-l2

Likely IOS and FED might be out of state, reload to use BO ports

FED_XCVR_MSG-3-CABLE_AUTH_FAILED

3-Error

*** Stack cable authentication failed for cable inserted on stack port [dec] on switch [dec] ***

Stack Cable authentication failed on the switch

polaris-l2

Fed would have crashed, remove the stack cable inserted in the mentioned port and cross check

FED_XCVR_MSG-3-CABLE_AUTH_FAILED_RELOAD

3-Error

Reloading chassis because cable auth failed on stack_port [dec]

Stack Cable authentication failed on the switch

polaris-l2

Fed would have crashed, remove the stack cable inserted in the mentioned port and cross check

FED_XCVR_MSG-3-NO_BO_SUCCESSFUL

3-Error

[dec] [dec] no break out successful

New BO command might have entered too fast or Deactivation taking time to clean feature objects

polaris-l2

Likely IOS and FED might be out of state, reload to use BO ports

FED_XCVR_MSG-3-NO_PG_SUCCESSFUL

3-Error

Slot [dec] Portgroup [dec] No Portgroup Successful

New PG command might have entered too fast or Deactivation taking time to clean feature objects

polaris-l2

Likely IOS and FED might be out of state, reload to use PG ports

FED_XCVR_MSG-3-PG_FAILED

3-Error

Slot [dec] Portgroup [dec] Failed

New PG command might have entered too fast or Deactivation taking time to clean feature objects

polaris-l2

Likely IOS and FED might be out of state, reload to use PG ports

FED_XCVR_MSG-3-PG_SUCCESSFUL

3-Error

Slot [dec] Portgroup [dec] Successful

New PG command might have entered too fast or Deactivation taking time to clean feature objects

polaris-l2

Likely IOS and FED might be out of state, reload to use PG ports

FED_XCVR_MSG-3-SPEED_MISMATCH

3-Error

[chars] are operating in different speeds, Ports in each port-group should operate in same speed. Please make sure that both the ports operate in same speed. Alternatively, Configure hw-module slot <> port-group <> select <speed>, shut and no shut preferred interface to use specific port in the port-group. This config is not supported if any of the ports in port-group is inserted with dual-rate optics.

The ports in port-group should be of the same speed for all ports to function

polaris-l2

Enter hw-module slot <> port-group <> select <speed>,followed by\n shut and no shut of interface to use a specific port.

FILTER-3-EWLC_APFILTER_REGEX_CREATE_ERR

3-Error

Error in [chars]

APFilter regular expression error

iosxe-binos-utils

Recreate regular expression correctly

FILTER-3-EWLC_GEN_ERR

3-Error

Error in [chars]

General Wireless LAN Controller Error Message.

iosxe-binos-utils

LOG_STD_ACTION

FILTER-4-EWLC_APFILTER_PRIORITY_UPDATE_WARN

4-Warning

Warning: [chars]

APfilter priorities are overridden, old filter will be invalid

iosxe-binos-utils

LOG_STD_ACTION

FILTER_BINARY_NOTIFICATION-5-MERGE_COMPLETED

5-Notice

Merged logs generation completed.

Notification to user that merged logs are generated

iosxe-binos-utils

Go to bootflash and view the merged logs

FIRMWARE-5-INSTALL_STATUS

5-Notice

Firmware install stage: [chars], install-id: [chars], message: [chars]

This syslog is generated during firmware installation which goes through multiple steps

lte-fw

No action is required

FIRMWARE-6-INSTALL_STATUS

6-Information

Firmware install stage: [chars], install-id: [chars], message: [chars]

This syslog is generated during firmware installation which goes through multiple steps

lte-fw

No action is required

FLASH_CHECK-3-DISK_QUOTA

3-Error

[chars] quota exceeded [free space is [dec] kB] - [recommended free space is [dec] kB] - Please clean up files on [chars].

The remaining free space on the disk is below the recommended threshold of at least 30 percent of the installed disk device space. This limits the system from core files necessary to root cause critical system faults. The disk device is bootflash or harddisk.

iosxe-binos-utils

Please remove unneeded files from the disk device. Any core files under the core directory should be reported and then deleted.

FLASH_CHECK-3-FLASH_ISSUE

3-Error

Detected Flash issues. Please issue the [chars] command at your earliest convenience.

eUSB failure is detected, flash partitions may be inaccessible.

iosxe-binos-utils

Please issue the cli command shown in the error message.

FLASH_CHECK-3-FLASH_RECOVERY

3-Error

Detected Flash issues. Proceeding with [chars] soft-error recovery.

eUSB failure is detected, which prevents access of flash partitions.

iosxe-binos-utils

No action required

FLASH_CHECK-3-RESET_FAIL

3-Error

Flash recovery failed. Please issue the reload slot <#> command at your earliest convenience.

An attempted flash recovery has failed. Switch needs to be manually reloaded

iosxe-binos-utils

No action required

FLASH_CHECK-3-RESET_SUCCESS

3-Error

Flash recovery was successful.

An attempted flash recovery was successful.

iosxe-binos-utils

No action required

FMANFP-3-CRYPTO_DEVICE_REQUEST_FAILED

3-Error

Crypto-device is busy processing last request. This request will be discarded

Crypto-device is still processing previous reload reqeust or still processing crypto feature packets. New request will not be applied

INVALID

LOG_STD_NO_ACTION

FMANFP-3-CRYPTO_LICENSE_THPUT_MAX_APPROACHED

3-Error

Average crypto throughput rate approached the licensed crypto bandwidth of [dec] bps during [dec] sampling periods in the last 24 hours, sampling period is [dec] seconds

To monitor crypto throughput and, to generate notification/warning if the average throuput utilization over a longer time are approaching or exceeding the cypro licensed bandwidth

iosxe-csl

LOG_STD_NO_ACTION

FMANFP-3-CRYPTO_LICENSE_THPUT_THRESHOLD_EXCEED

3-Error

Average crypto throughput rate exceeded [dec] percent of licensed crypto bandwidth of [dec] bps during [dec] sampling periods in the last 24 hours, sampling period is [dec] seconds

To monitor crypto throughput and, to generate notification/warning if the average throuput utilization over a longer time are approaching or exceeding the cypro licensed bandwidth

iosxe-csl

LOG_STD_NO_ACTION

FMANFP-3-LICENSE_THPUT_INVALID

3-Error

Invalid throughput [dec]kbps

The throughput value is invalid. The forwarding engine will not operate at the throughput value.

iosxe-csl

LOG_STD_DDTS_TAC_DETAILS

FMANFP-3-REFGRP_ENTRY_LIMIT_EXCEED

3-Error

Reflexive group [chars]([dec]) exceeded limitation of [dec] entries. Reflexive functionality is not supported for this ACE, please remove it.

A software limitation has been exceeded.

INVALID

LOG_STD_NO_ACTION

FMANFP-3-REFGRP_LIMIT_EXCEED

3-Error

Number of reflexive group exceeded limitation of [dec]. Reflexive functionality is not supported for this ACE, please remove it.

A software limitation has been exceeded.

INVALID

LOG_STD_NO_ACTION

FMANFP-3-REF_ACE_IDX_LIMIT_EXCEED

3-Error

Reflexive group [chars]([dec]) ACE index([dec]) exceeded limitation of [dec]. Reflexive functionality is not supported for this ACE, please remove it.

A software limitation has been exceeded.

INVALID

LOG_STD_NO_ACTION

FMANFP-3-REF_ACL_IDX_LIMIT_EXCEED

3-Error

Reflexive group [chars]([dec]) ACL index([dec]) exceeded limitation of [dec]. Reflexive functionality is not supported for this ACL, please remove it.

A software limitation has been exceeded.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-CRYPTO_DEVICE_NOT_PRESENT

6-Information

Hardware crypto-device is not present. Request aborted

Hardware crypto-device is not present on the system. User request doesn't apply or be executed. This may not be an error.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-CRYPTO_DEVICE_REQUEST_COMPLETE

6-Information

Crypto-device is ready to process packets

Crypto-device is load with new core based on user request. Now it is ready to process packets

INVALID

LOG_STD_NO_ACTION

FMANFP-6-FMANACLLOGMISSMSG

6-Information

access-list logging datapath rate-limited or missed [dec] packet[chars]

Some packet matching logs were missed because the access list log messages were rate-limited or no access list log buffers were available.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPACCESSLOGDP

6-Information

list [chars] [chars] [chars] [chars][chars] [chars]-> [chars] ([dec]/[dec]), [dec] packet[chars]

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPACCESSLOGNP

6-Information

list [chars] [chars] [dec] [chars][chars] [chars]-> [chars], [dec] packet[chars]

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPACCESSLOGP

6-Information

list [chars] [chars] [chars] [chars][chars]([dec]) [chars]-> [chars]([dec]), [dec] packet[chars]

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPACCESSLOGSGDP

6-Information

ingress_interface='[chars]' sgacl_name='[chars]' action='[chars]' protocol='[chars]' src-ip='[chars]' dest-ip='[chars]' type='[dec]' code='[dec]' sgt='[dec]' dgt='[dec]' logging_interval_hits='[dec]'

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPACCESSLOGSGNP

6-Information

ingress_interface='[chars]' sgacl_name='[chars]' action='[chars]' protocol='[dec]' src-ip='[chars]' dest-ip='[chars]' sgt='[dec]' dgt='[dec]' logging_interval_hits='[dec]'

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPACCESSLOGSGP

6-Information

ingress_interface='[chars]' sgacl_name='[chars]' action='[chars]' protocol='[chars]' src-ip='[chars]' src-port='[dec]' dest-ip='[chars]' dest-port='[dec]' sgt='[dec]' dgt='[dec]' logging_interval_hits='[dec]'

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPV6ACCESSLOGDP

6-Information

list [chars] [chars] [chars] [chars][chars] [chars]-> [chars] ([dec]/[dec]), [dec] packet[chars]

A packet matching the log criteria for the given access list was detected.

iosxe-acl

LOG_STD_NO_ACTION

FMANFP-6-IPV6ACCESSLOGNP

6-Information

list [chars] [chars] [dec] [chars][chars] [chars]-> [chars], [dec] packet[chars]

A packet matching the log criteria for the given access list was detected.

iosxe-acl

LOG_STD_NO_ACTION

FMANFP-6-IPV6ACCESSLOGP

6-Information

list [chars] [chars] [chars] [chars][chars]([dec]) [chars]-> [chars]([dec]), [dec] packet[chars]

A packet matching the log criteria for the given access list was detected.

iosxe-acl

LOG_STD_NO_ACTION

FMANFP-6-IPV6ACCESSLOGSGDP

6-Information

ingress_interface='[chars]' sgacl_name='[chars]' action='[chars]' protocol='[chars]' src-ip='[chars]' dest-ip='[chars]' type='[dec]' code='[dec]' sgt='[dec]' dgt='[dec]' logging_interval_hits='[dec]'

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPV6ACCESSLOGSGNP

6-Information

ingress_interface='[chars]' sgacl_name='[chars]' action='[chars]' protocol='[dec]' src-ip='[chars]' dest-ip='[chars]' sgt='[dec]' dgt='[dec]' logging_interval_hits='[dec]'

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANFP-6-IPV6ACCESSLOGSGP

6-Information

ingress_interface='[chars]' sgacl_name='[chars]' action='[chars]' protocol='[chars]' src-ip='[chars]' src-port='[dec]' dest-ip='[chars]' dest-port='[dec]' sgt='[dec]' dgt='[dec]' logging_interval_hits='[dec]'

A packet matching the log criteria for the given access list was detected.

INVALID

LOG_STD_NO_ACTION

FMANRP-3-OBJ_DWNLD_TO_FP_FAILED

3-Error

[chars] download to FP failed

An object has failed to download to the forwarding processor (FP)

iosxe-fwdmgr

Examine the process logs to identify the cause for object download failure

FMANRP-3-PEER_IPC_RESET

3-Error

IPC to [chars] has been reset after previous stuck

IPC to a peer has been reset after previous stuck

iosxe-fwdmgr

check if there is any functional impact after recovery

FMANRP-3-PEER_IPC_RESUME

3-Error

IPC to [chars] has returned to normal after previous stuck

IPC to a peer is back to normal after previous stuck

iosxe-fwdmgr

check if there is any functional impact after recovery

FMANRP-3-PEER_IPC_STUCK

3-Error

IPC to [chars] is stuck for more than [dec] seconds

IPC to a peer is stuck, resulting no new messages sent over for a long time

iosxe-fwdmgr

Run show platform peer object-manager rp [active|standby] to confirm that no new messages are sent over the Config IPC

FMANRP-4-INVALID_CCE_POSITION

4-Warning

Invalid position '[dec]' prevented [chars]

A messaging error has occurred during service-policy modification and the configuration could not be downloaded properly

iosxe-fwdmgr

LOG_STD_DDTS_TAC_DETAILS

FMAN_CAPWAP-3-AP_TUNNEL_CLEANUP_PENDING

3-Error

AP CAPWAP tunnel cleanup is incomplete. [chars]

CAPWAP tunnel delete acknowledgement is not yet received from FMAN FP

ewlc-ap

LOG_STD_ACTION

FMAN_CAPWAP-3-AP_TUNNEL_EXIST

3-Error

AP CAPWAP tunnel plumb failure. [chars]

CAPWAP tunnel plumb failure due to MAC or IFID conflict

ewlc-ap

LOG_STD_ACTION

FMAN_IPSEC_NGWC-3-IPSEC_ANTI_REPLAY_ERR

3-Error

IPSEC (flow id [dec]) receives anti-replay error.

traffic being received is not within the IPSec anti-replay window.

iosxe-fwdmgr

Check the size of anti-replay window configured. Adjust to maximum 256-bits if needed

FMAN_IPSEC_NGWC-3-IPSEC_CONFIG_FAIL

3-Error

IPSEC fail to configure because [chars].

The IPSEC configuration has failed. This could be due to a hardware/software resource limitation or a software defect.

iosxe-fwdmgr

Check the logs for information. Reconfigure IPSEC

FMAN_IPSEC_NGWC-3-IPSEC_INIT_FAIL

3-Error

IPSEC fail to initialize because [chars].

The IPSEC initialization has failed. This could be due to a hardware/software resource limitation or a software defect.

iosxe-fwdmgr

Check the logs for information. Reboot the system if IPSEC needs to be configured

FMAN_IPSEC_NGWC-3-IPSEC_TTL_NOT_SUPPORT

3-Error

IPSEC tunnel ttl configuration ignored because [chars].

The IPSEC configuration for tunnel ttl value is not supported and therefore has been ignored.

iosxe-fwdmgr

remove tunnel ttl configuration as it is not supported.

FMAN_IPSEC_NGWC-3-IPSEC_TUNNEL_CONFIG_FAIL

3-Error

[chars] SADB [dec] IF_ID [dec]

The IPSEC configuration has failed. This could be due to a hardware/software resource limitation or a software defect.

iosxe-fwdmgr

Check the logs for information. Reconfigure IPSEC

FMFP-3-DP_NOMEM

3-Error

DP not enough memory. [chars]

An object download to DP failed because the memory of DP is not enough.

iosxe-fwdmgr

Run show platform resource to see the memory usage

FMFP-3-INTERFACE_OBJECT_NOT_FOUND

3-Error

Interface object lookup by [chars] not found for interface [dec]

The desired interface object was not found.

iosxe-fwdmgr

Examine the interface state in the operating system, route processor (RP) and forwarding processor (FP) forwarding manager logs.

FMFP-3-OBJ_ACK_FROM_DP_RESUME

3-Error

AOM ack of objects to Data Plane is back to normal

An object ack from lower layer to FMAN-FP has finished after a temporary stuck. It can be caused by incomplete configuration or software defects

iosxe-fwdmgr

check if there is any functional impact after recovery

FMFP-3-OBJ_ACK_FROM_DP_STUCK

3-Error

AOM ack download to Data Plane is stuck for more than [dec] seconds [chars]

An object ack from lower layer to FMAN-FP has taken long time. It can be caused by incomplete configuration or software defects

iosxe-fwdmgr

Run show platform software object-manager fp [active|standby] [pending-ack-update| pending-ack-batch|pending-ack-commands] sorted <min_pending_time> to see the sorted list of update/ batch/command in pending state for more than the min_pending_time. For incomplete configuration, use show platform platform software object fp [active|standby] resolve to see if there is any resolve object

FMFP-3-OBJ_DWNLD_TO_DP_FAILED

3-Error

[chars] download to DP failed

An object has failed to download to the data plane

iosxe-fwdmgr

Examine the list of error objects in the forwarding processor (FP) forwarding manager asynchronous object logs.

FMFP-3-OBJ_DWNLD_TO_DP_RESUME

3-Error

AOM download of objects to Data Plane is back to normal

An object download from FMAN-FP to lower layer has finished after a temporary stuck. It can be caused by incomplete configuration or software defects

iosxe-fwdmgr

check if there is any functional impact after recovery

FMFP-3-OBJ_DWNLD_TO_DP_STUCK

3-Error

AOM download to Data Plane is stuck for more than [dec] seconds [chars]

An object download from FMAN-FP to lower layer has taken long time. It can be caused by incomplete configuration or software defects

iosxe-fwdmgr

Run show platform software object-manager fp [active|standby] [pending-issue-update|pending-issue-batch] sorted <min_pending_time> to see the sorted list of update/batch/ command in pending state for more than the min_pending_time. For incomplete configuration, use show platform platform software object fp [active|standby] resolve to see if there is any resolve object

FMFP_ACL-3-ACL_LIMIT_EXCEEDED

3-Error

ACL [chars] exceeded limitation of [dec] ACEs per ACL

A software limitation has been exceeded.

iosxe-fwdmgr

Reduce the access control list (ACL) configuration. A reboot of the forwarding processor (FP) is recommended.

FMFP_ACL-3-ACL_MODIFY_FAILED

3-Error

ACL:[chars] modification through object group edit failed

Object-group used in the ACL was modified. Those changes could not be accommodated in the ACL

asr1k-acl

Fix the object-group changes. Delete ACL and reconfigure it

FMFP_ACL-3-ACL_OBJECT_DOWNLOAD

3-Error

[chars][chars] fail to download because [chars].

The access control list (ACL) object has failed to download. This could be due to a hardware or software resource limitation or a software defect.

iosxe-fwdmgr

Check the logs for information on the relevant object download states. Remove the ACL attachment to the interface or delete the ACL. Reboot the forwarding processor (FP).

FMFP_ACL-3-ACL_PROTOCOL_CHECK

3-Error

ACL [chars] protocol does not match what was previously configured

The error occurs for one of two reasons. An access control list (ACL) reference was made to an ACL of a different protocol; or an ACL was added or edited when there were similarly named ACL references of a different protocol

iosxe-fwdmgr

Remove the conflicting ACL or the conflicting ACL references.

FMFP_ACL-3-OGACL_BINCODE_CHECK

3-Error

[chars] OGACL request failed in bincode check: required bits ([dec]) max available bits ([dec]).

The scaled OGACL failed to download due to the hardware or software resource limitation on bincode.

asr1k-acl

Check the logs for information on the relevant object download states. Remove the OGACL configuration and binding, reduce the scaling and reconfigure it

FMFP_ACL-3-OGACL_PD_RESOURCE

3-Error

[chars] OGACL runs out of PD resources.

The scaled OGACL failed to download due to PD hardware or software resource limitation.

asr1k-acl

Check the logs for information on the relevant object download states. Remove the OGACL configuration and binding, reduce the scaling and reconfigure it

FMFP_ACL-3-SGACL_OBJECT_DOWNLOAD

3-Error

SGACL Cell ([dec] [dec]) policy [chars] fail to download because [chars].

The SGACL policy has failed to download. This could be due to a hardware or software resource limitation or a software defect.

iosxe-fwdmgr

Check the logs for information on the relevant object download states. Remove the SGACL policy for that cell, correct the error and reconfigure it

FMFP_CCK-4-INCONSISTENCY_FOUND

4-Warning

Consistency Checker(CCK) detected inconsistency for [chars]. Check 'show consistency-checker run-id [dec] detail'.

CCK has detected the inconsistency between the IOSD and fmanFP tables.

iosxe-fwdmgr

Find out the entry using the show consistency-checker <> command

FMFP_CXSC-3-CXSC_DEINITIALIZATION

3-Error

[chars] Returned: [chars]

The CXSC DEINITIALIZATION has FAILED. This could be due to a hardware or software resource limitation or a software defect.

iosxe-cxsc

Check memory usage and router configuration and try to re-activate virtual service again. If it shows the same results then please contact TAC.

FMFP_CXSC-3-CXSC_DOMAIN_CONFIG

3-Error

[chars] Returned: [chars]

The CXSC DOMAIN CONFIG DOWNLOAD has FAILED. This could be due to a hardware or software resource limitation or a software defect.

iosxe-cxsc

Check memory usage and router configuration and try to re-activate virtual service again. If it shows the same results then please contact TAC.

FMFP_CXSC-3-CXSC_INITIALIZATION

3-Error

[chars] Returned: [chars]

The CXSC INITIALIZATION has FAILED. This could be due to a hardware or software resource limitation or a software defect.

iosxe-cxsc

Check memory usage and router configuration and try to re-activate virtual service again. If it shows the same results then please contact TAC.

FMFP_CXSC-3-CXSC_POLICY_DOWNLOAD

3-Error

[chars] Returned: [chars]

The CXSC POLICY DOWNLOAD has FAILED. This could be due to a hardware or software resource limitation or a software defect.

iosxe-cxsc

Check memory usage and router configuration and try to re-activate virtual service again. If it shows same results then please contact TAC.

FMFP_CXSC-6-CXSC_POLICY_DOWNLOAD_SUCCESS

6-Information

New policy version: [dec] has now been installed and is active

The CXSC POLICY DOWNLOAD of the numbered version has succeeded.

iosxe-cxsc

This an informational message only, no action is required. Note that policy version is not monotonically increasing so there is nothing to be concerned about if the current installed policy version is less than the previous installed policy version.

FMFP_QOS-4-QOS_WITHOUT_UPDATING

4-Warning

Warning, Qos download AOM without updating [chars]

qos download aom wihtout updating action.

iosxe-fwdmgr

No action is required.

FMFP_QOS-6-QOS_STATS_PROGRESS

6-Information

statistics are progressing

QoS statistics are now progressing normally. This is an informational message.

iosxe-fwdmgr

No action is required.

FMFP_QOS-6-QOS_STATS_STALLED

6-Information

statistics stalled

QoS statistics are temporarily stalled. This is an informational message.

iosxe-fwdmgr

No action is required.

FMFP_URPF-3-LIST_DOWNLOAD

3-Error

Unicast RPF list [chars] for list [dec] fail to download because [chars].

The unicast reverse path forwarding (URPF) list failed to download. This can be caused by a hardware or software resource limitation or software defect.

iosxe-fwdmgr

Check the logs for information on the relevant download states. Reboot the forwarding processor (FP).

FMFP_URPF-3-OBJECT_DOWNLOAD

3-Error

Unicast RPF [chars] on inteface [chars] fail to download because [chars].

The unicast reverse path forwarding (URPF) operation failed to download. This can be caused by a hardware or software resource limitation or a software defect.

iosxe-fwdmgr

Check the logs for information on the relevant download states. Remove the uRPF feature enabled on any interface. Reboot the forwarding processor (FP).

FMRP_CCK-4-INCONSISTENCY_FOUND

4-Warning

Consistency Checker(CCK) detected inconsistency for [chars]. Check 'show consistency-checker run-id [dec] detail'.

CCK has detected the inconsistency between the IOSD and fmanRP tables.

iosxe-fwdmgr

Find out the entry using the show consistency-checker <> command

FPGA_DRV-1-CRC_ERR

1-Alert

SEU [chars] errors are detected in FPGA, [chars]\n

SEU errors are detected in FPGA

INVALID

LOG_STD_ACTION

FPMD-3-ACL_PROGRAM_FAILURE

3-Error

Failed to associate access-list: [chars]. Reason: [chars]

This syslog is generated when FPMD cannot program or partially programmed given access-list in datapath. This error can result into packets flowing through the network without applying access-list as intended

vip-cedge-policy

Check btrace for any error logs, collect tech-support and share with Cisco TAC

FPMD-3-MAX_FILTER_EXCEEDED

3-Error

Filter count exceeded Max ([dec]) filters per class for class_id [dec] at filter_id [dec]

This syslog is generated when maximum number of filters have already been reached for given class

vip-cedge-policy

Remove any unused filters from given class

FPMD-3-POLICY_PROGRAM_FAILURE

3-Error

Failed to associate data-policy [chars] with vpn-list: [chars]. Reason: [chars]

This syslog is generated when FPMD cannot program or partially programmed given data-policy in datapath. This error can result into packets flowing through the network without applying data-policy as intended

vip-cedge-policy

Check btrace for any error logs, collect tech-support and share with Cisco TAC

FPMD-3-SDWAN_POLICE_CONFIRM_BURST_INCREASED

3-Error

SDWAN Policer [chars] Conform burst [dec] increased to [dec]

This syslog is generated when FPMD receives policer config but configured policer burst is less than the default burst tolerance for the CIR

vip-cedge-policy

Check btrace for any error logs, collect tech-support and share with Cisco TAC

FPMD-5-FLOW_LOG

5-Notice

FLOW LOG device-vpn: [dec] tenant-vpn: [dec] src: [chars]/[dec] dst: [chars]/[dec] proto: [dec] tos: [dec] direction: [chars], policy: [chars], sequence: [dec], Result: [chars] Pkt count: [dec] bytes: [dec] Ingress-Intf: [chars] Egress-intf: [chars] Tenant: [chars]

This syslog is generated for every flow that matches data-policy, app-route policy and/or access-list. The log contains information about L3 and L4 headers, along with direction and result

vip-cedge-policy

No action is required

FPMD-6-ACL_PROGRAM_SUCCESS

6-Information

Successfully associated access-list: [chars]

This informative log is generated when access-list is successfully programmed in data-path

vip-cedge-policy

No action is required

FQDN_MESSAGE-3-FQDN_FLEX_ERR

3-Error

Error in [chars]

ewlc fqdn flex push error message.

iosxe-binos-utils

LOG_STD_ACTION

FQDN_MESSAGE-3-FQDN_LISTNAME_ERR

3-Error

Error in [chars]

ewlc FQDN url list name error message.

iosxe-binos-utils

LOG_STD_ACTION

FQDN_MESSAGE-3-FQDN_LOCAL_ERR

3-Error

Error in [chars]

ewlc fqdn urllist forwarding push error message.

iosxe-binos-utils

LOG_STD_ACTION

FTMD-3-FIB_ROUTE_ADD_FAIL

3-Error

Route addition failed for prefix [chars], reason [chars]

This syslog is typically generated when the system is under stress and a route cannot be added in forwarding base

cedge-forwarding

Please collect tech-support and share with Cisco TAC, a support ticket should be created to debug this

FTMD-3-TLOC_ADD_FAIL

3-Error

TLOC ([chars]/[chars]) addition failed, reason: [chars]

This syslog is typically generated when the system is under stress and a TLOC cannot be added in forwarding base or encountered a error

cedge-forwarding

No action is required

FTMD-5-FLOW_LOG

5-Notice

**HSL-LOGGING IMPLICIT-ACL** vpn: [dec], source: [chars]/[dec], destination: [chars]/[dec], protocol: [dec], tos: [dec], reason: [chars], packets: [dec], bytes: [dec], ingress-interface: [chars], egress-interface: [chars]

This syslog is generated whenever a packet hits implicit ACL

cedge-forwarding

No action is required

GEOFENCE-2-DEVICE_LOCATION_INSIDE

2-Critical

Device location is inside Geofencing range ([chars]) current latitude/longitude: (%.6f, %.6f)

This syslog is generated when the device location is inside configured Geofencing range

geo-fencing

No action is required

GEOFENCE-2-DEVICE_LOCATION_LOST

2-Critical

Device location unavailable [chars]

This syslog is generated when the device location is lost

geo-fencing

No action is required

GEOFENCE-2-DEVICE_LOCATION_OUTSIDE

2-Critical

Device location is outside Geofencing range, current latitude/longitude: (%.6f, %.6f)

This syslog is generated when the device location is outside configured Geofencing range

geo-fencing

No action is required

GEOFENCE-5-DEVICE_LOCATION_UPDATE

5-Notice

Device location changed by more than 20 meters from last report, current latitude/longitude: (%.6f, %.6f)

This syslog is generated when the device moves within configured Geofencing range

geo-fencing

No action is required

GEOFENCE-6-DEVICE_TRACKING_STARTED

6-Information

Device Tracking started in Geofencing mode ([chars])

This syslog is generated when device tracking is started

geo-fencing

No action is required

GEOFENCE-6-DEVICE_TRACKING_STOPPED

6-Information

Device Tracking stopped in Geofencing mode

This syslog is generated when device tracking is stopped while Geofencing feature is enabled

geo-fencing

No action is required

GEO_CLOUDM-5-EXEC_CLI

5-Notice

Exec CLI : [chars]

Information message related to exec cli

ewlc-ap-location

LOG_STD_NO_ACTION

GEO_CLOUDM-5-RANGING_REQUEST

5-Notice

Ranging request : [chars]

Information message related to ranging request

ewlc-ap-location

LOG_STD_NO_ACTION

GNMIB-5-SRV_ADMIN_SCN

5-Notice

Component [ [chars] ] administrative state: [chars]

gnmib component administrative state

polaris-gnmi-infra

ACTION_NONE_REQUIRED

GNMIB-5-SRV_OPER_SCN

5-Notice

Component [ [chars] ] operational status: [chars]

gnmib component operational status

polaris-gnmi-infra

ACTION_NONE_REQUIRED

GNMIB-6-GRPC_CON_STATE

6-Information

Received gRPC [chars] from [chars] for RPC [chars]

gRPC Connection state logging

polaris-gnmi-infra

ACTION_NONE_REQUIRED

GNMIB-6-GRPC_CON_STATE_AUTH

6-Information

Received gRPC [chars] from [chars] for RPC [chars] for user [chars] group [chars]

gRPC Connection state logging with user authentication

polaris-gnmi-infra

ACTION_NONE_REQUIRED

GNMIB-6-GRPC_TUNN_SESS

6-Information

Received gRPC Tunnel session request from [chars] for Target Type [chars]

gRPC Tunnel state logging

polaris-gnxi-infra

ACTION_NONE_REQUIRED

GNMIB-6-GRPC_TUNN_STATE

6-Information

Connected to gRPC Destination [chars] ([chars]) with Targets[[chars]] using [chars]:[chars]

gRPC Tunnel state logging

polaris-gnxi-infra

ACTION_NONE_REQUIRED

GREENLIB-6-SUBSCRIPTION_RECORD_NOT_SENT

6-Information

Subscription record from DB [[chars]] and table [[chars]] was not sent out due to [[chars]]

A record for an On-change Subscription was not sent due to the size of the record being too large

iosxe-p-db

LOG_STD_ACTION

HFSLIB-3-HFSINOFAILED

3-Error

Inotify failed to initialize : [chars]

This error occurs when the inotify sub-system is misbehaving

iosxe-chassismgr

LOG_STD_NO_ACTION

HFSLIB-3-HFSINOWATCH

3-Error

Inotify failed to add a watch: [chars]

This error occurs when the inotify sub-system is misbehaving

iosxe-chassismgr

LOG_STD_NO_ACTION

HFSLIB-3-HFSOPEN

3-Error

Problem accessing the udev generated file: [chars]

No explanation.

iosxe-chassismgr

LOG_STD_NO_ACTION

HL_CORE-3-MAY_DEFER_WRAPPER_RESCHEDULE_FAILED

3-Error

Failed to (re)schedule CPUHOG protected loop. Operation will be aborted. Please check the logs for more details.

Hyperlocation was interrupted while trying to defer a looping operation and can not continue.

iosxe-binos-utils

LOG_STD_NO_ACTION

HL_MGR-3-CMX_IPV6_IN_FABRIC

3-Error

CMX [chars] connected over IPv6 which is not currently supported for Hyperlocation in Fabric mode.

Currently the Fabric mode only operates over IPv4.

iosxe-binos-utils

Please connect the CMX over IPv4, or change the mode to flex/local.

HL_MGR-3-NEXTHOP_OUTPUT_INTERFACE_NOT_SVI

3-Error

CMX [chars] is reachable through a routed port with MAC address %pM. This deployment configuration is not supported for Hyperlocation

CMX should be reachable via a SVI (VLAN) interface for traffic forwarding to be operational

iosxe-binos-utils

Please rejoin CMX.

HMAN-2-INITIALIZATION_FAILED

2-Critical

Host Manager initialization failed.

Initialization of the host manager failed.

iosxe-hostmgr

Review Host Manager logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

HMAN-3-CONSOLE_SETUP_FAILED

3-Error

Failed to setup console service. It should be enabled on [chars]

Setup of a console service failed.

iosxe-hostmgr

Check the host manager launch parameters and correct as required.

HMAN-3-HOSTNAME_SET_FAILED

3-Error

Failed to set hostname: [chars]

The host manager received notification that the system hostname has been set. The host manager failed to pass this value to the ASR kernel.

iosxe-hostmgr

Repeat the process to configure the hostname. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

HMAN-3-VRF_API_FAILED

3-Error

[chars], vrf ([chars]) - ret ([dec])

The host manager has received notification that the VRF information needs to be modified. The host manager failed to perform the operation due to the error indicated in the log.

iosxe-hostmgr

Collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

HMAN_CPU-3-PAGE_FAULT_HIGH

3-Error

CPU Usage due to Memory Pressure exceeds threshold on [chars]. Below are the top 5 memory consuming processes: [chars] (PID=[dec]; RSS=[dec] KB), [chars] (PID=[dec]; RSS=[dec] KB), [chars] (PID=[dec]; RSS=[dec] KB), [chars] (PID=[dec]; RSS=[dec] KB), [chars] (PID=[dec]; RSS=[dec] KB)

When CPU usage due to Major Page Fault exceeds a pre-defined threshold for a CPU core, this error message is emitted.

iosxe-hostmgr

No action is needed if system continues to perform as expected. If sytem performance deteriorate (and eventually, system reloads due to unspecified reason) around the time when this message is observed, open a case with the Technical Assistance Center via the following Internet link, or contact your Cisco technical support representative: http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl

HW_IDPROM_ENVMON-2-ACT2_UDI_DATA_INVALID

2-Critical

The act2 udi secure area format mismatch with unsecure area

This Router may not have been manufactured by Cisco or with Cisco's authorization. This product may contain software that was copied in violation of Cisco's license terms. If your use of this product is the cause of a support issue, Cisco may deny operation of the product, support under your warranty or under a Cisco technical support program such as Smartnet. Please contact Cisco's Technical Assistance Center for more information.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

HW_IDPROM_ENVMON-3-HW_IDPROM_CHECKSUM_INVALID

3-Error

The idprom contains an invalid checksum in a sensor entry. Expected: %x, calculated: %x

If this error occurs then parsing of the environmental monitoring data is aborted. Environmental monitoring will be either incomplete or absent entirely.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

HW_IDPROM_ENVMON-3-HW_IDPROM_FIELD_INVALID

3-Error

The idprom contains an invalid environmental monitoring field.

If this error occurs then parsing of the environmental monitoring data is aborted. Environmental monitoring will be either incomplete or absent entirely.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

HW_IDPROM_ENVMON-3-PS_IDPROM_INVALID_PID

3-Error

[chars] in slot PFU[dec] has INVALID PID [chars] and it needs to be replaced immediately

The PID read from the PEM IDPROM is not supported in this hardware configuration. It will be allowed to continue but immediate replacement is required

iosxe-chassismgr

LOG_STD_RECUR_ACTION

HW_PFU-3-PFU_IDPROM_CORRUPT

3-Error

The PEM/FM idprom could be read, but is corrupt in slot P[dec] The system will run without environmental monitoring for this component

The idprom contains information required in order to properly operate the environmental monitoring subsystems. The idprom could not be read, therefore no monitoring will take place.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

HW_PFU-3-PFU_IDPROM_INVALID_PID

3-Error

The PEM/FM idprom has invalid PID in slot PFU[dec] The system will run without environmental monitoring for this component

The idprom contains PID information required in order to properly operate the environmental monitoring subsystems. The idprom PID is invalid , therefore no monitoring will take place.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

HW_PFU-3-PFU_IDPROM_READ_ERR

3-Error

Could not read the PEM/FM idprom in slot P[dec].The system will run without environmental monitoring for this component

The idprom contains information required in order to properly operate the environmental monitoring subsystems. The idprom could not be read, therefore no monitoring will take place.

iosxe-chassismgr

LOG_STD_RECUR_ACTION

HW_PFU-3-PFU_UNSUPPORTED_PID

3-Error

The PEM/FM in slot P[dec] is not supported. The system will run without environmental monitoring for this component

The PEM/FM inserted in not supported by this platform. Replace with a supported module.

asr900-system-rsp3

LOG_STD_RECUR_ACTION

ID_MANAGER-3-ID_MANAGER_INTERNAL_ERROR

3-Error

Internal erorr occurred: [chars]

Internal Error occured with ID Manager

iosxe-binos-utils

LOG_STD_ACTION

ID_MANAGER-3-INVALID_ID

3-Error

bad id in [chars] (id: 0x%08X)

An ID Manager error occurred

iosxe-binos-utils

LOG_STD_ACTION

ID_MANAGER-3-INVALID_ID_TABLE_SIZE

3-Error

bad new ID table size

A bad new table request to ID Manager occurred

iosxe-binos-utils

LOG_STD_ACTION

IFM-3-RSRC_L3_LE_ERR

3-Error

Interface [chars] creation failed due to L3 Interface hardware resource exhaustion

Hardware resource for L3 Interface exhausted and the requested interface will not be created.

INVALID

Collect output of show platform hardware fed switch <switch number> fwd-asic resource utilization command. Check if RSC_L3IF_LE has exhausted. If yes, free up any unused L3 Interfaces by doing no interface <interface> and retry creating the failed interface.

ILET-2-AUTHENTICATION_FAIL

2-Critical

The system integrity check has failed during the boot-up sequence. Please contact Cisco's Technical Assistance Center for more information.

Trusted Anchor module detected an invalid SUDI.

iosxe-hostmgr

Please contact Cisco's Technical Assistance Center for more information

IM-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

polaris-infra

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

IM-0-UIPEER_CREATE

0-Emergency

Failed to create user interface peer.

The system failed to create a user interface peer.

polaris-infra

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

IM-2-ACTIVATION_STATE

2-Critical

[chars] '[chars]' [chars] [chars]

The activation state of the named virtualization service has changed as notified by IOx-manager.

polaris-infra

In the failed case, check IOx-manager's logs for the cause of the failure. In the successful case, this notification can be ignored.

IM-2-ALLOC_VIRT_INST_RCS

2-Critical

Virtualization Service[chars]

A memory allocation request failed to allocate a data structure required to activate the virtualization service.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-CPUSHARES_LIMIT

2-Critical

Virtualization Service[chars]

The virtualization service machine definition file is requesting more CPU shares than the system has available for virtualization services.

polaris-infra

Deactivate any other virtualization services to free up CPU share resources and activate this virtualization service. If that does not address the problem, then enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-DEACT_FOR_ISSU

2-Critical

[chars] Max ([dec]s)

An ISSU event is pending. Any active VMs will be automatically deactivated to allow ISSU preprocessing to validate the environment. Any ISSU-deactivated VMs will be automatically restarted if the ISSU is cancelled.

polaris-infra

None. Allow the ISSU to continue and the VMs will restart when the ISSU completes; or cancel the ISSU and IOx-manager will automatically restart the VMs.

IM-2-DISK_IMAGE_PATH

2-Critical

Virtualization Service[chars]

The virtualization service machine definition file contains an invalid disk image path for one of the disk devices. This may be a Harddisk, CDROM or USB storage device.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-FIND_VIRT_INST_ENTRY

2-Critical

Failed to find virtualization service with id [dec] in the IOx-manager list

The virtualization service with the ID named could not be located in the IOx-manager list.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-GENERAL_FAILURE

2-Critical

Virtualization Service[chars]

The named virtualization service has triggered the log. Please interpret the log in the context of the virtualization services.

polaris-infra

No action is required

IM-2-GUESTSHELL_ENABLED

2-Critical

The guest shell has been enabled. The command '[chars]' may be used to access it, '[chars] destroy' to remove it.

Informs the user that the guest shell virtualization service has been enabled (which is done by default).

polaris-infra

The user may use or remove the guest shell with the commands specified.

IM-2-HA_STATE

2-Critical

[chars] [chars] [chars] [chars]

IOx-manager tries to detect the role/slot of various nodes on HA events from the platform. If any of those event callbacks fail, this notification would be raised.

polaris-infra

In the failed case, check IOx-manager's logs for the cause of the failure. Check for the HA event error msg and root cause the same.

IM-2-HA_SWITCHOVER_STATE

2-Critical

[chars] [chars] [chars] [chars]

IOx-manager HA switchover state related messages for a virtual-service whilst it is being recovered on newly active RP after a HA switchover.

polaris-infra

In the failed case, check IOx-manager's logs for the cause of the failure. Check for the HA event error msg and root cause the same.

IM-2-HA_SYNC_ERR

2-Critical

[chars] '[chars]' [chars]

The ha-sync persistent storage disk for the virtualization service cannot be watched for sync to standby RP.

polaris-infra

Collect the IOx-manager logs and scan them for the cause.

IM-2-HA_SYNC_THREAD_STATE

2-Critical

HA remote sychronize thread has failed and exited.

IOx-manager tries to remote sync the OVA repository to all online nodes using a separate thread. If that thread fails, this notification would be raised.

polaris-infra

In the failed case, check IOx-manager's logs for the cause of the failure. Check for the pthread error msg and root cause the same.

IM-2-INITIALIZATION_FAILED

2-Critical

Initialization of [chars] failed for IOx Manager

Initialization of IOx Manager process failed.

polaris-infra

Review ioxman logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log.

IM-2-INSTALL_FAILURE

2-Critical

Virtualization Service[chars]

The installation of the virtualization service failed.

polaris-infra

Enable the IOx-manager trace logs and repeat the installation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-INSTALL_LOG

2-Critical

[chars] [chars] [chars] [chars]

The installation log of the named virtualization service, is to provide more information about long running operation, that could affect the control of CLI

polaris-infra

No action is required

IM-2-INSTALL_MEDIA_RETRY

2-Critical

VM install media still unavailable.[chars]

The install media was not detected. Waiting for udev to complete install media(harddisk) detection.

polaris-infra

After IOx-manager exceeds the maximum retry limit, verify if install media (harddisk) is accessible and retry the installation again.

IM-2-INSTALL_STATE

2-Critical

[chars] '[chars]'[chars] [chars]

The installation state of the named virtualization service has changed as notified by IOx-manager.

polaris-infra

In the failed case, check IOx-manager's logs for the cause of the failure. In the successful case, this notification can be ignored.

IM-2-INVALID_ACT_MSG

2-Critical

Virtualization Service[chars]

The virtualization service activate message was received, however, the data it contained could not be interpreted

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-INVALID_DEACT_MSG

2-Critical

Failed to process virtualization service deactivate message

The virtualization service deactivate message was received, however, the data it contained could not be interpreted

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-INVALID_UNPROV_MSG

2-Critical

Failed to process virtualization service unprovision message

The virtualization service unprovision message was received, however, the data it contained could not be interpreted

polaris-infra

Enable the IOx-manager trace logs and repeat the activation followed by deactivation and then unprovision of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-IOX_INST_CRIT

2-Critical

IOX SERVICE [chars] LOG: [chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

polaris-infra

No action is required

IM-2-IOX_INST_LOG_UNTHROTTLE

2-Critical

Failed to unthrottle the log for IOX service [chars]

The named IOX service had sent overwhelming sys log messages and its log had been throttled as a result, but system has failed to unthrottle it for some reason.

polaris-infra

For debugging collect the ioxman logs and scan them for the cause.

IM-2-MEMORY_LIMIT

2-Critical

Virtualization Service[chars]

The virtualization service machine definition file is requesting more memory than the system has available for virtualization services.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-MOVE_STATE

2-Critical

[chars] '[chars]' [chars] [chars]

The move of the core or log file of the named virtualization service has as been successful or failed as notified by IOx-manager.

polaris-infra

In the failed case, check IOx-manager's logs for the cause of the failure. In the successful case, this notification can be ignored.

IM-2-NETWORK_CONFIG_ERROR

2-Critical

Virtualization Service[chars]

A network configuration error has been detected for the named virtualization service.

polaris-infra

No action is required

IM-2-RESET_FORCE

2-Critical

Virtualization Services non-recoverable reset command processed

A 'virtualization service reset force' command has been entered and processed. This action initiates a cleanup of last resort. Occasionally a VM will get into an unrecoverable state that prevents it from activating but also from uninstalling. This is a rare event but when it happens the only resort may be to remove the .conf control file and reboot, which forces a cleanup of all previously installed VM files and artifacts. Note that once this command is used, current VMs are considered to be in an unstable or unpredictable state, and all future install, uninstall, upgrade, and activation commands will be blocked.

polaris-infra

Once the command is entered and accepted, there is no recourse but to restart the system.

IM-2-RESIZE_OPER_STATE

2-Critical

Virtualization service '[chars]' [chars][chars] to '[dec]' [chars]

IOx-manager attempts to resize various VM parameters like rootfs size, CPU share, memory if requested by user. Success/failure status messages for these resize operations are communicated by this syslog.

polaris-infra

In the failed case, check IOx-manager's logs for the cause of the failure. Check for the HA event error msg and root cause the same.

IM-2-RSYNC_STATE

2-Critical

[chars] [chars] [chars] [chars]

IOx-manager tries to remote sync the virtual-instance configuration file and the OVA repository to all online nodes. If rsync fails even after consecutive retries, this notification would be raised.

polaris-infra

In the failed case, check IOx-manager's logs for the cause of the failure. Check for the rsync error code and root cause the same.

IM-2-START_FAILED

2-Critical

Virtualization Service[chars]

The named virtualization service failed to start.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-UNINSTALL_ALL_VMS

2-Critical

All Virtualization Services are being uninstalled [chars][chars] [chars]

All virtualization services are being uninstalled by IOx-manager.

polaris-infra

Examine the reason given as to why all virtualization services are being uninstalled for more information. If the reason indicated is due to some error condition, check IOx-manager's logs for the cause of the failure.

IM-2-UPGRADE_LOG

2-Critical

[chars] [chars] [chars] [chars]

The upgrade log of the named virtualization service, is to provide more information about long running operation, that could affect the control of CLI

polaris-infra

No action is required

IM-2-VCPU_INVALID

2-Critical

Virtualization Service[chars]

The virtualization service machine definition file is requesting invalid VCPU value.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-VCPU_LIMIT

2-Critical

Virtualization Service[chars]

The virtualization service machine definition file is requesting more VCPUs than the system has reserved for virtualization services.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-VIRT_INST_DISK

2-Critical

Virtualization Service[chars]

The virtualization service requires Disk Storage in excess of the Free Disk Storage available to virtualization services.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-VIRT_INST_LOG_UNTHROTTLE

2-Critical

Failed to unthrottle the log for virtualization service [chars]

The named virtualization service had sent overwhelming sys log messages and its log had been throttled as a result, but system has failed to unthrottle it for some reason.

polaris-infra

For debugging collect the iox-manager logs and scan them for the cause.

IM-2-VIRT_INST_MEMORY

2-Critical

Virtualization Service[chars]

The virtualization service requires physical memory in excess of the free memory available to virtualization services.

polaris-infra

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause.

IM-2-VIRT_INST_MGMT_INTERFACE

2-Critical

Virtualization service [chars] has no management interface defined but it is configured in CLI.

A management interface is configured but none is defined.

polaris-infra

Deactivate the virtualization service, remove the management interface configuration CLI, and reactivate the virtual-service.

IM-2-VIRT_INST_STATE

2-Critical

Virtualization Service[chars]

The named virtualization service has failed. It is no longer running either because the guest OS has failed, the guest OS has shut down the machine or the emulator has failed.

polaris-infra

An attempt at restarting the virtualization service can be made from the IOS configuration by doing a no activate/activate. For debugging collect the IOx-manager logs and scan them for the cause.

IM-3-IOX_INST_ERR

3-Error

IOX SERVICE [chars] LOG: [chars]

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.

polaris-infra

No action is required

IM-3-IOX_NETMASK_ERR

3-Error

app configuration has wrong [chars] netmask.

The netmask configuration is wrong.

polaris-infra

Configure guest-ipaddress with IPV4 or IPV6 netmask.

IM-3-PSS_ERR

3-Error

Purpose: [chars], URI: [chars], errcode: [dec]

Persistent Storage Service handling error

polaris-infra

Collect the IOx-manager logs and scan them for the cause.

IM-3-PSS_SNAPSHOT_ERR

3-Error

Source URI: [chars], Destination URI: [chars], errcode: [dec]

Persistent Storage Service snapshot error

polaris-infra

Collect the IOx-manager logs and scan them for the cause.

IM-3-SDWRAP_ERR

3-Error

Description: [chars], errcode: [dec]

Debug infrastructure error

polaris-infra

Collect the IOx-manager logs and scan them for the cause.

IM-4-HA_SYNC_NEEDED

4-Warning

If using the guest shell, please use 'guestshell sync' if you want to preserve state on standby in case of supervisor switchover

Message notifying user that he needs to manually synchronize the Virtualization service contents to standby supervisor in order to preserve these contents in case of a supervisor switchover. Currently only applicable to the guest shell

polaris-infra

User can type the 'guestshell sync' command on active supervisor to synchronize it's contents to the standby supervisor if desired.

IM-4-IOX_INST_WARN

4-Warning

IOX SERVICE [chars] LOG: [chars]

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.

polaris-infra

No action is required

IM-4-WATCHDOG_TIMER

4-Warning

[chars] '[chars]' [chars] [chars]

The watchdog timer configured for the named virtual service has expired.

polaris-infra

Check any logs produced by the virtualization service to determine the cause.

IM-5-AUX

5-Notice

Virtualization Service[chars]

The AUX login to a virtualization service may allow the user access to system functions that may not have been tested or may interact with the system in unintended ways. Use with caution.

polaris-infra

No action is required

IM-5-IOX_INST_NOTICE

5-Notice

IOX SERVICE [chars] LOG: [chars]

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.

polaris-infra

No action is required

IM-5-IOX_IPV6_NOTICE

5-Notice

guest-interface([dec]), IPV6 address configured with guest-ipaddress is ignored

The IPV6 address configuration with guest-ipaddress is ignored. 'ipv6-address' has been configured and multiple static IPV6 addresses are not supported

polaris-infra

Configure guest-ipaddress with IPV4 address.

IM-5-IOX_NOTICE

5-Notice

app-hosting: [chars]

The generic IOX notice. Please interpret the log in the context of the information provided.

polaris-infra

No action is required

IM-5-IOX_URL_COPY_MSG

5-Notice

URL Copy: [chars]

Copy a package file from URL

polaris-infra

Check if 'ip name-server', 'ip name-server vrf Mgmt-vrf' and 'ip http' are configured properly for the device

IM-5-IOX_VPG_IPV6_MSG

5-Notice

no IPv6 address for VirtualPortGroup[dec] in IOS_Oper_DB

VirtualPortGroup IPv6 address is not present in IOS_Oper_DB

polaris-infra

Check if 'show ip interface brief' displays IPv6 for the VirtualPortGroup

IM-5-PERMISSION_DENIED

5-Notice

Virtualization Service '[chars]' is not owned by client IOSd

An attempt was made to modify a virtual-service that is not owned by by the client. The request was rejected.

polaris-infra

No action is required.

IM-6-ACTIVATE_MSG

6-Information

app-hosting: [chars]

Message for activating an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-6-DEACTIVATE_MSG

6-Information

app-hosting: [chars]

Message for deactivating an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-6-INSTALL_MSG

6-Information

app-hosting: [chars]

Message for installing an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-6-IOX_ENABLEMENT

6-Information

IOX is ready.

Message for IOX enablement.

polaris-infra

No action is required

IM-6-IOX_INST_INFO

6-Information

IOX SERVICE [chars] LOG: [chars]

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.

polaris-infra

No action is required

IM-6-IOX_MEDIA_MSG

6-Information

dynamic media: [chars]

Message for IOX shared median

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-6-IOX_RECONCILE_INFO

6-Information

App-hosting application reconcile process [chars]

Indicates stage of reconcile (application recovery) process.

polaris-infra

No action is required

IM-6-IOX_START_FAIL

6-Information

[chars] failed to start

Indicates starting an app after installation.

polaris-infra

No action is required

IM-6-IOX_START_INFO

6-Information

[chars] cannot be started because it is not installed

Indicates starting an app before installation.

polaris-infra

No action is required

IM-6-IOX_START_SUCCESS

6-Information

[chars] is in RUNNING state

Indicates starting an app after installation.

polaris-infra

No action is required

IM-6-START_MSG

6-Information

app-hosting: [chars]

Message for starting an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-6-STOP_MSG

6-Information

app-hosting: [chars]

Message for stopping an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-6-UNINSTALL_MSG

6-Information

app-hosting: [chars]

Message for uninstalling an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-6-UPGRADE_MSG

6-Information

app-hosting: [chars]

Message for upgrading an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-6-VERIFICATION_MSG

6-Information

app-hosting: [chars]

Message for signature verification

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IM-7-IOX_INST_DEBUG

7-Debug

IOX SERVICE [chars] LOG: [chars]

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.

polaris-infra

No action is required

IMGR-0-FIPS_CPP_CLIENT_BYPASS_TEST

0-Emergency

CPP Client FIPS bypass test failed for [chars]\n.

Forwarding Manager CPP client IPSEC bypass test failed. This could be due to a hardware malfunction or a software defect.

iosxe-fwdmgr

If the problem persists reboot the forwarding processor (ESP).

IMGR-0-FIPS_FMFP_BYPASS_TEST

0-Emergency

NIST bypass test failed for [chars].\n

Forwarding Manager IPsec component detected a discrepancy when adding or deleting a security sensitive object. This could be due to a hardware or software resouce limitation or a software defect.

iosxe-fwdmgr

Check the logs for information on the relevant object download states. Remove the object or a parent object in question. If the problem persists reboot the forwarding processor (ESP).

IMGR-0-FIPS_FMFP_N2_SEVERE_ERR_FAIL

0-Emergency

Cryptographic coprocessor severe failure: [chars]\n.

Cryptographic coprocessor critical operation failed. Further data processing on ESP is halted

iosxe-fwdmgr

forwarding processor (ESP) is rebooted automatically. no action needed

IMGR-6-FIPS_FMFP_CRNG_TEST

6-Information

continuous [chars]approved RNG test failed.\n

Forwarding Manager IPsec component detected two identical random number sequences. This could be due to a hardware mulfunction or a software defect.

iosxe-fwdmgr

If the problem persists reboot the forwarding processor (ESP).

IMGR-6-FIPS_FMFP_KAT_TEST

6-Information

power up cryptographic self-test did not run to completion: [chars]\n.

Forwarding Manager power up known answer self-test (KAT) failed. This could be due to a hardware malfunction or a software defect.

iosxe-fwdmgr

If using ipsec, reboot the forwarding processor (ESP).

IMGR-6-FIPS_FMFP_N2_ERR_FAIL

6-Information

Cryptographic coprocessor non-critical failure: [chars]\n.

Cryptographic coprocessor non-critical operation failed. If the problem persists reboot the forwarding processor(ESP)

iosxe-fwdmgr

If the problem persists reboot the forwarding processor (ESP).

IMGR-6-FIPS_FMFP_OLAP_TEST

6-Information

FIPS-approved RNG key seed and state overlap.\n

Forwarding Manager IPsec component detected an overlap in FIPS-approved RNG key seed and state. This could be due to a hardware mulfunction or a software defect.

iosxe-fwdmgr

If the problem persists reboot the forwarding processor (ESP).

IMGR-6-FMFP_CRYPTO_DEVICE_BUSY

6-Information

All Crypto Device cores are busy with data packets.\n

All ESP crypto device are busy.

qfp-ipsec

May need to lower crypto traffic rate.

IMGR-6-FMFP_IPSEC_CRYPTO_CTRL_THROTTLED

6-Information

IPsec Control Plane Overload Crypto Device: [chars].

This ESP crypto device is overloaded.

qfp-ipsec

May need to config platform ipsec control-plane medium|heavy

IMGR-6-FMFP_IPSEC_MIN_MTU_INFO

6-Information

MTU smaller than minimum IPSec MTU, [chars]\n.

Minimum MTU supported by crypto processor is 256B, MTU lower than 256B is set to 256B

iosxe-fwdmgr

No action needed

IMGR-6-FMFP_IPSEC_UNSUPPORTED_CIPHER

6-Information

Cipher [chars] is not supported on this ESP.

This ESP does not support this IPSec cipher

iosxe-fwdmgr

No action needed

IMGR-6-FMFP_KAT_TEST_RESULT

6-Information

crypto self-test for algorithm: ([chars] ... passed)\n.

Forwarding Manager power up known answer self-test (KAT) success. This is not an error message

iosxe-fwdmgr

No action needed.

INSTALL-3-INSTANT_ERROR_MESSAGE

3-Error

Error Message: [chars]

This message is used to send a instant erorr message.

iosxe-binos-utils

No action required.

INSTALL-3-OPERATION_ERROR_MESSAGE

3-Error

Failed to [chars] package [chars], Error: [chars]

This message is used to inform the failure reason.

iosxe-binos-utils

Please refer to the error message to analyze the cause of failure.

INSTALL-5-INSTALL_AUTO_ABORT

5-Notice

Install auto abort timer expired: initiating abort

An install operation has been aborted because the auto abort timer has expired.

iosxe-binos-utils

No user action is needed. If you want to commit the ISSU upgrade, redo the upgrade. Otherwise, this is an informational message only.

INSTALL-5-INSTALL_AUTO_ABORT_TIMER_PROGRESS

5-Notice

Install auto abort timer will expire in [dec] seconds

An install operation will be aborted after specified seconds of time.

iosxe-binos-utils

No user action is needed. If you want to commit the ISSU upgrade, redo the upgrade. Otherwise, this is an informational message only.

INSTALL-5-INSTALL_COMPLETED_INFO

5-Notice

Completed [chars] [chars] [chars]

This message is used to indicate the completion of install operations.

iosxe-p-install

No action required. This is not an error, it is an indication that the system completed this operation.

INSTALL-5-INSTALL_SCHEDULE_TIMER_PROGRESS

5-Notice

Install schedule timer will expire in [dec] seconds

An install operation will be started after specified seconds of time.

iosxe-p-install

No user action is needed. This is an informational message only.

INSTALL-5-INSTALL_START_INFO

5-Notice

Started [chars] [chars] [chars]

This message is used to indicate the beginning of install operations.

iosxe-p-install

No action required. This is not an error, it is an indication that the system is starting this operation.

INSTALL-5-OPERATION_COMPLETED_INFO

5-Notice

Completed [chars] package [chars]

This message is used to indicate the completion of operations.

iosxe-binos-utils

No action required. This is not an error, it is an indication that the system completed the operation.

INSTALL-5-OPERATION_START_INFO

5-Notice

Started [chars] package [chars]

This message is used to indicate the beginning of operations.

iosxe-binos-utils

No action required. This is not an error, it is an indication that the system is starting the operation.

IOMD_ETHER_GEIM-2-MAX_LIMIT_XCVR

2-Critical

Number of [chars] that can be supported has reached the max limit of [dec], transceiver is err-disabled. Unplug the transceiver in interface [chars]

Because of power constraints, we can support only limited number of high power transceivers in certain platforms. If we insert more than the limit, it will be disabled. It is recommended to unplug the transceiver

INVALID

Unplug the transceiver once the max limit is reached

IOMD_ETHER_GEIM-3-FIFO_OVERFLOW

3-Error

[chars] fifo overflow occurred for port [dec]

A hardware error in phy has occurred

asr900-im

Examine the IOMD logs for Phy driver or hardware errors. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_ETHER_GEIM-3-INTERRUPT_ERR

3-Error

interrupt handling error [chars]

Interrupt could not be handled because of internal sw error

INVALID

Examine the IOMD logs. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_ETHER_GEIM-4-LC_OIR_REQD

4-Warning

Found mismatch between the line card Phy firmware versions bundled in software and programmed in hardware in slot [dec]. To upgrade the Phy firmware to version bundled in software, perform physical OIR of the line card or run the CLI: hw-module subslot [dec]/[dec] oir power-cycle. If ISSU is in progress, firmware upgrade should be done only after the completion of ISSU. To check the firmware versions, use the CLI: show firmware version all

During ISSU the software does not upgrade the PHY firmware. PHY firmware upgrade needs a reset and will lead to data path down time. Hence software avoids PHY firmware upgrade. This causes a mismatch between the firmware bundled in the image and that programmed in the PHY. Due to this mismatch any new features claimed by the new software will not be automatically enabled and needs a manual upgrade via power-cycle of the line card

INVALID

To upgrade to latest phy firmware, do physical OIR or soft OIR of the line card using CLI: hw-module subslot <slot>/<bay> oir power-cycle. To view the present phy firmware version, use the CLI: show platform hardware iomd <slot>/<bay> ethernet_controllers phy <port number> api-version or show firmware version all

IOMD_ETHER_GEIM-4-NOT_SUPPORTED

4-Warning

1G Transceiver is inserted in slot [dec] for ports [chars]. The current linecard phy firmware does not support 1G capability. To upgrade the firmware, perform physical OIR of the line card or use the CLI: hw-module subslot [dec]/0 oir power-cycle. If ISSU is in progress, firmware upgrade should be done only after the completion of ISSU

During ISSU the software does not upgrade the PHY firmware. PHY firmware upgrade needs a reset and will lead to data path down time. Hence software avoids PHY firmware upgrade. This causes a mismatch between the firmware bundled in the image and that programmed in the PHY. Due to this mismatch any new features claimed by the new software like 1G will not be automatically enabled and needs a manual upgrade via power-cycle of the line card

INVALID

To upgrade to latest phy firmware, do physical OIR or soft OIR of the line card using CLI: hw-module subslot <slot>/<bay> oir power-cycle. To view the present phy firmware version, use the CLI: show platform hardware iomd <slot>/<bay> ethernet_controllers phy <port number> api-version or show firmware version all

IOMD_ETHER_GEIM-4-NOT_SUPPORTED_XCVR

4-Warning

1G Transceiver is inserted in slot [dec] for port [dec]. The current linecard phy firmware does not support 1G capability. To upgrade the firmware, perform physical OIR of the line card or use the CLI: hw-module subslot [dec]/0 oir power-cycle

During ISSU the software does not upgrade the PHY firmware. PHY firmware upgrade needs a reset and will lead to data path down time. Hence software avoids PHY firmware upgrade. This causes a mismatch between the firmware bundled in the image and that programmed in the PHY. Due to this mismatch any new features claimed by the new software like 1G will not be automatically enabled and needs a manual upgrade via power-cycle of the line card

INVALID

To upgrade to latest phy firmware, do physical OIR or soft OIR of the line card using CLI: hw-module subslot <slot>/<bay> oir power-cycle. To view the present phy firmware version, use the CLI: show platform hardware iomd <slot>/<bay> ethernet_controllers phy <port number> api-version or show firmware version all

IOMD_ETHER_GEIM-4-QSA28_UNSUPPORTED_MODE

4-Warning

On SLOT [dec], QSA28 transceiver plugged into port [dec] configured in 40G mode is not supported. Please remove QSA28 from the port or configure the port as 100G.

QSA28 is supported only on 100G ports.

INVALID

Unplug QSA28 from the port or change the port configuration to 100G.

IOMD_ETHER_GEIM-4-QSA_UNSUPPORTED_MODE

4-Warning

On SLOT [dec], QSA transceiver plugged into port [dec] configured in 100G mode is not supported. Please remove QSA from the port or configure the port as 40G.

QSA is supported only on 40G ports.

INVALID

Unplug QSA from the port or change the port configuration to 40G.

IOMD_ETHER_GEIM-4-REMOVE_XCVR

4-Warning

Unplug the transceiver in interface [chars], keeping transceiver can have impact on other transceiver in the same port-group

Inserting an incompatible transceiver is not recommended since it can have impact on other transceiver in the same port-group

INVALID

Unplug the incompatible transceiver

IOMD_ETHER_GEIM-4-UNSUPPORTED_TRANSCEIVER

4-Warning

On SLOT [dec], Transceiver plugged into port [dec] is not supported. Please remove the transceiver.

It's not recommended to insert unsupported transceivers.

INVALID

Unplug the transeiver.

IOMD_ETHER_GEIM-5-LINK_INCONSISTENCY

5-Notice

Inconsistency detected between hardware and software parameters in slot [dec] for ports [chars], restoring the consistency. Link flap or traffic drop might be observed on these ports during this process

During switchover or ISSU, if the serdes parameters are different in active and standby, these parameters will be reprogrammed. This may result in link flap or traffic drop momentarily

INVALID

No action is required

IOMD_ETHER_GEIM-5-MODULE_REINIT_REQUIRED

5-Notice

Hardware parameters on PHY for slot [dec] need modification, Which may have an impact on link and traffic during switchover. User intervention is required to fix the problem by reloading slot [dec]. Use the command 'hw-module subslot [dec]/0 oir power-cycle' to reset the slot during maintainance

Hardware parameters need to be updated on PHY. Due to hardware limitation these parameters cannot be applied dynamically. For applying these parameters we need reload linecard

INVALID

Perform Linecard reload by using below command so that parameter changes get commited to hardware. If this step is not performed then you may face a link flap and traffic loss during switchover Command : hw-module subslot <slot>/0 oir power-cycle

IOMD_ETHER_GEIM-6-STBY_PORTS_INITIALIZED

6-Information

Interfaces on slot [dec] are initialized on standby and ready for switchover

All the interfaces on standby for particular slot is initialized and Interface are ready for switchover.

INVALID

No action is required.

IOMD_ETHER_GEIM-6-UNSUPPORTED_MODE

6-Information

On SLOT [dec] QSFP transceiver plugged into 40G port [dec] and a QSA module plugged into port [dec] is unsupported combination. To linkup the desired connections, please remove QSFP transceiver from port [dec] as well as QSA module from port [dec] and then insert only the required QSFP transceiver or QSA module in the respective port.

Due to a hardware limitation in PHY, QSFP Optics on top port and QSA module on bottom port is not supported

INVALID

Unplug the error disabled transceiver

IOMD_INFRA-3-I2C_READ

3-Error

An I2C read has failed because [chars]

An I2C read has failed. This could be due to a hardware or software defect.

asr900-im

Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

IOMD_INFRA-3-I2C_WRITE

3-Error

An I2C write has failed because [chars]

An I2C write has failed. This could be due to a hardware or software defect.

asr900-im

Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

IOMD_INFRA-3-INTR_EVENT

3-Error

IOMd fast thread event ([dec]).

IOMd fast thread event

asr900-im

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA-3-INVALID_BAY_NUM

3-Error

An invalid bay number is specified in one of the internal APIs. bay=[dec] max_bay=[dec]

Invalid bay number to find the TDL domain

asr900-im

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA-3-INVALID_SLOT_NUM

3-Error

An invalid slot number is specified in one of the internal APIs. slot=[dec] max_slot=[dec]

Invalid slot number to find the TDL domain

asr900-im

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA-3-IPCALLOCFAIL

3-Error

Failed to allocate IPC buffer [chars]

The IM failed to allocate a buffer for communication with RSP

asr900-im

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA-3-IPCSENDFAIL

3-Error

IOMD failed to send a message [chars] reason: [chars]

IOMD failed to send message to the RP

asr900-im

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA-3-LINECARDDIAGSFAILED

3-Error

Module [chars] in Slot [dec] failed online diagnostics. Please use 'show post' for more details

Online Diag has failed. This could be due to a hardware or software defect.

asr900-im

Note the time of the error message and examine the logs for errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

IOMD_INFRA-3-SVL_SPEED_MISMATCH

3-Error

Speed of SVL Port [dec] in Slot [dec] does not match with other SVL Links. Please take neccessary action.

Speed of this SVL Link does not match with the speed of other SVL Links This can be due to replacement of a cable with different Speed on SVL port.

asr900-im

Please check the operating speed of this SVL Link and the operating speed of the other SVL Links.If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

IOMD_INFRA-4-BADPOINTER

4-Warning

Function [chars] detected an invalid [chars] pointer of %08lX, ignoring

A software error has occurred, this message is displayed when an invalid pointer is detected.

asr900-im

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA-4-FAN_ALARM

4-Warning

Interface [chars], fan alarm [chars]

Fan alarm due to temperature

INVALID

For MINOR, action is <fill minor action> For MAJOR, action is <fill major action> For CRITICAL, action is <fill critical action>

IOMD_INFRA-4-INTR_OVER_LIMIT

4-Warning

IOMd main thread disabled interrupt for [dec] msec.

IOMd main thread process disabled interrupt too long

asr900-im

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA-4-LC_OIR_REQD

4-Warning

Found mismatch between the line card Phy firmware versions bundled in software and programmed in hardware in slot [dec]. To upgrade the Phy firmware to version bundled in software, perform physical OIR of the line card or run the CLI: hw-module subslot [dec]/[dec] oir power-cycle. If ISSU is in progress, firmware upgrade should be done only after the completion of ISSU. To check the firmware versions, use the CLI: show firmware version all

During ISSU the software does not upgrade the PHY firmware. PHY firmware upgrade needs a reset and will lead to data path down time. Hence software avoids PHY firmware upgrade. This causes a mismatch between the firmware bundled in the image and that programmed in the PHY. Due to this mismatch any new features claimed by the new software will not be automatically enabled and needs a manual upgrade via power-cycle of the line card

INVALID

To upgrade to latest phy firmware, do physical OIR or soft OIR of the line card using CLI: hw-module subslot <slot>/<bay> oir power-cycle. To view the present phy firmware version, use the CLI: show platform hardware iomd <slot>/<bay> ethernet_controllers phy <port number> api-version or show firmware version all

IOMD_INFRA-6-BEACON_LED_TURNED

6-Information

Slot [dec] Port [dec] Beacon LED turned [chars]

Beacon LED turned ON/OFF. This is a notification message only.No action is required.

INVALID

This is a notification message only. No action is required.

IOMD_INFRA-6-HIGH_POWER_OPTICS_DETECTED

6-Information

The port [chars] supports optics with a max power of [dec].[dec] W, but inserted optics max power is [dec].[dec] W. This can lead to operational issues for these and neighbouring ports. To identify allocated port max power, please execute the CLI: [chars]

Due to a thermal limitation, insertion of High power QSFP/SFP Optics in this port is not suggested.

INVALID

Unplug the high power XCVR.

IOMD_INFRA-6-HIGH_POWER_OPTICS_PRESENT

6-Information

The line card [dec] has optic(s) inserted in port(s) that has power limitations. The optics max power is more than the power recommended. This can lead to operational and thermal issues for these and neighbouring ports. To identify allocated port max power, please execute the CLI: [chars]

Due to a thermal limitation, insertion of High power QSFP/SFP Optics in some ports is not advised.

INVALID

Unplug the high power XCVR.

IOMD_INFRA-6-STBY_PORTS_INITIALIZED

6-Information

Interfaces on slot [dec] are initialized on standby and ready for switchover

All the interfaces on standby for particular slot is initialized and Interface are ready for switchover.

INVALID

No action is required.

IOMD_INFRA-6-TDLMSG_INCOMPATIBLE

6-Information

Failed to copy message [chars] to buffer, not allowed for current domain.

Failure to marshal a message indicates an incompatibility with the intended recipient.

asr900-im

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA-6-UNSUPPORTED_MODE

6-Information

Transceiver module in [chars] going in err-disabled state.

Breakout optics is not supported in non-breakout port; Non-breakout optics is not supported in breakout port

INVALID

Unplug the error disabled transceiver

IOMD_INFRA-6-UNSUPPORTED_MODE_BREAKOUT

6-Information

Transceiver module in [chars] going in err-disabled state.

Breakout optics is not supported in non-breakout port; Non-breakout optics is not supported in breakout port

INVALID

Unplug the error disabled transceiver

IOMD_INFRA-6-UNSUPPORTED_SPEED_COMBINATION

6-Information

On SLOT [dec] QSFP 100G/40G transceiver plugged into port [dec] and a QSA module plugged into port [dec] is unsupported combination. To linkup the desired connections, please remove QSFP transceiver from port [dec] as well as QSA module from port [dec] and then insert only the required QSFP transceiver or QSA module in the respective port.

Due to a hardware limitation in PHY, QSFP Optics on top port and QSA module on bottom port is not supported

INVALID

Unplug the error disabled transceiver

IOMD_STARFLEET-5-LINK_RECOVERY

5-Notice

Interface [chars] link recovery mechanism triggered [Reason: System Side Signal down]

Link recovery mechanism detected a system side signal issue on UADP transmit. Recovery mechanism was triggered for correcting it.

INVALID

No action is required.

IOSD-3-BIPC_REJECT

3-Error

Could not accept ipc connection: [chars]

This error occurs if shell-manager has denied an ipc connection request from IOS.

iosxe-shellmgr

Check the connection request parameters.

IOSD-3-TDL_PROPERTIES

3-Error

Could not set message properties for connection: [chars]

This error occurs if shell-manager is unable to set message properties for the IOS-sman connection

iosxe-shellmgr

Check the connection request parameters.

IOSXE_UPGRADE_ROMMON-0-ROMMON_LOADTEST_FAIL

0-Emergency

ROMMON FIPS_140-3 Load test *FAILED*: file [chars]

FIPS 140-3 Related Load test failed for the ROMmon.

iosxe-binos-utils

Check the system messages to see if any messages appeared that might indicate the source of the ROMmon Load test problem. If you do not find any additional information indicating a correctable problem, collect all output on the screen, in particular the console port output after the upgrade rom-monitor command was entered and the output of show rom-monitor, and provide the collected information to a Cisco technical support representative.

IOSXE_UPGRADE_ROMMON-0-ROMMON_UPGRADE_FAIL

0-Emergency

ROMMON upgrade failed: partition [chars]

An attempt to upgrade the ROMmon failed.

iosxe-binos-utils

Check the system messages to see if any messages appeared that might indicate the source of the ROMmon problem. If you do not find any additional information indicating a correctable problem, collect all output on the screen, in particular the console port output after the upgrade rom-monitor command was entered and the output of show rom-monitor, and provide the collected information to a Cisco technical support representative.

IOXCAF-5-GUESTSHELL_IPV4_NOTICE

5-Notice

guestshell ip address([chars]) of Mgmt-Intf is ignored.

The ipv4 address configured for guestshell's Mgmt-Intf is ignored. When guestshell is on Mgmt-Intf it is natted and has an internal 192.168 ipv4 address.

polaris-infra

No action is required

IOXCAF-5-GUESTSHELL_IPV6_NOTICE

5-Notice

guestshell ipv6 address([chars]) of Mgmt-Intf is ignored.

The ipv6 address configured for guestshell Mgmt-Intf is ignored. When guestshell is on Mgmt-Intf it is natted and has an internal 192.168 ipv4 address. Therefore there is no need to provide a static ipv6 address to guestshell interfaces.

polaris-infra

No action is required

IOXCAF-6-INSTALL_MSG

6-Information

app-hosting: [chars]

Message for installing an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IOXCAF-6-UPGRADE_MSG

6-Information

app-hosting: [chars]

Message for upgrading an app.

polaris-infra

In the failed case, check Ioxman's trace log for the cause of the failure. In the successful case, this notification can be ignored.

IOXMGR-2-DNAC_EGRESS_INTF_NOT_SVI

2-Critical

Not supported: egress interface ([chars]) towards Cisco-DNAC server [chars] is not an SVI

Egress interface to reach the Cisco-DNAC server is restricted to be an SVI

ewlc-iot-gw

If this message occurs, the egress interface towards the Cisco-DNAC server needs to be configured as an SVI

IOXMGR-2-DNAC_EGRESS_INTF_NO_GLOB_IPV6_ADDR

2-Critical

Cisco-DNAC configured address is IPv6, but no global IPv6 address configured on egress interface [chars]

At least one local IPv6 global/routable address is needed to reach the Cisco-DNAC server

ewlc-iot-gw

If this message occurs, at least one IPv6 global address needs to be configured on the egress interface towards the Cisco-DNAC server.

IPC_ERRMSG-4-IPC_WARNING_TRACE

4-Warning

Warning, [chars]

General warning message with traceback

ewlc-app-infra

LOG_STD_ACTION

IPC_LOG-3-IPC_LOGWRITE_FAILED

3-Error

ipc log write [dec] bytes failed because [chars]

An internal logging mechanism failed to write a message.

iosxe-binos-utils

No action is required. However, if router performance is noticeably degraded, contact Cisco Technical Assistance. Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information.

ISSU-0-BOOT_SYNC_FAIL

0-Emergency

Problem with sync of ISSU boot state - [chars]

The ISSU state between two FRUs is not properly synchronized as a result of a boot error.

iosxe-binos-utils

This message will automatically appear during certain events, such as during a FRU removal or if the FRU loses connectivity. In most cases, the router will resynchronize the ISSU state between the FRUs without any user intervention. If the ISSU state is not resynchronized after multiple attempts, the problem is likely a result of another problem. Monitor the other system messages to see if a more serious issue has occurred on your router. If you are unable to resolve this other issue and this message persists, gather the output of show tech-support and provide it to a Cisco technical support representative.

ISSU-0-PKG_INCONSIST

0-Emergency

Reason: [chars]

A software consolidated package or sub-package has an error that indicates the sub-package should not be installed or used.

iosxe-binos-utils

If this message is received, the desired consolidated package or sub-package should not be used. Upgrade using a different consolidated package or sub-package, and report the problem consolidated package or sub-package to Cisco technical support.

ISSU-0-PKG_MNT_SCRIPT_FAIL

0-Emergency

Package: [chars]

A consolidated package or sub-package has encountered an error indicating it is not usable.

iosxe-binos-utils

Upgrade your software using a different consolidated package or sub-package.

ISSU-0-RESET_FRU_FAIL

0-Emergency

Problem with ISSU reset of remote FRU - [chars]

After a sub-package installation, one or more FRUs that were upgraded failed to initialize within the timeout period.

iosxe-binos-utils

This problem is more likely to occur in routers with larger configurations, so if your router has a large configuration, you may want to wait a few more minutes to see if your hardware initializes. If the hardware continues to not initialize, reset the FRUs which failed to initialize. If resetting the FRUs fails to resolve the issue, gather the output of show tech-support and contact a Cisco technical support representative.

ISSU-0-SOFTWARE_INVALID

0-Emergency

Package for location [chars]: [chars]

The sub-packages have encountered an error related to the structure of the loaded software.

iosxe-binos-utils

This error is likely caused by a failure of the boot or installation process or a corrupted provisioning file. If the system displays error messages related to the boot that can be addressed, address those messages. Downloading new software, if possible, may also help with the problem. If the problem persists, gather the output of show tech-support and provide it to a Cisco technical support representative.

ISSU-3-BOOT_SYNC

3-Error

Problem with sync of ISSU boot state - [chars]

The ISSU state between two FRUs is not properly synchronized as a result of a boot error.

iosxe-binos-utils

This message will automatically appear during certain events, such as during a FRU removal or if the FRU loses connectivity. In most cases, the router will resynchronize the ISSU state between the FRUs without any user intervention. If the ISSU state is not resynchronized after multiple attempts, the problem is likely a result of another problem. Monitor the other system messages to see if a more serious issue has occurred on your router. If you are unable to resolve this other issue and this message persists, gather the output of show tech-support and provide it to a Cisco technical support representative.

ISSU-3-BOOT_UNCLEAN

3-Error

Found reload log file, moved to [chars]

A log file was found at bootup indicating that all shutdown tasks were not performed on a previous reload.

iosxe-binos-utils

No user action is necessary. The system will automatically resolve most issues related to the shutdown task as part of the bootup procedure. If a problem related to the tasks that did not shutdown occurs, another error message will occur providing information about that problem.

ISSU-3-INCOMPAT

3-Error

The packages in [chars] are not consistent

The sub-packages specified for running on the chassis are not compatible with one other.

iosxe-binos-utils

Install a compatible set of packages to allow normal operation. This will require booting a known-good package set.

ISSU-3-ISSU_COMP_CHECK_FAILED

3-Error

ISSU compatibility check failed for [chars]

The image is not ISSU compatible

polaris-issu-infra

Please add another ISSU compatible image to start ISSU

ISSU-3-SYNC_ERR

3-Error

Problem with sync of state - [chars]

The software state between two FRUs or switches is not properly synchronized as a result of a boot error.

iosxe-binos-utils

This message may appear during certain events, such as during a FRU or switch removal or if the FRU or switch loses connectivity. In most cases, the router will resynchronize the software state between the FRUs or switches without any user intervention. If the software state is not resynchronized after multiple attempts, the problem is likely a result of another problem. Monitor the other system messages to see if a more serious issue has occurred on your router. If you are unable to resolve this other issue and this message persists, gather the output of show tech-support and provide it to a Cisco technical support representative.

ISSU-3-UCODE_INCOMPAT

3-Error

Found mismatch for ucode feature - [chars]

During boottime microcode feature version check, a version mismatch was found for this feature.

iosxe-binos-utils

Please ensure that versions of features in microcode are compatible by provisioning a different set of microcode files.

ISSU-5-ISSU_AUTO_ROLLBACK

5-Notice

ISSU rollback timer expired: initiating rollback

An ISSU upgrade has been rolled back because the rollback timer has expired.

iosxe-binos-utils

No user action is needed. If you want to commit the ISSU upgrade, redo the upgrade. Otherwise, this is an informational message only.

ISSU-5-ISSU_STAGE_INFO

5-Notice

STAGE [chars]: [chars] [chars]\n

This message is used to indicate the start/completion of ISSU stages.

polaris-issu-infra

No action required. This is an indication that ISSU stage has started or completed

ISSU-5-ISSU_STATE_INVALID

5-Notice

ISSU stored state found invalid and cleaned up: [chars]

The RP has corrected a failed ISSU install state that was detected at bootup.

iosxe-binos-utils

No user action is necessary. This is an informative message indicating that the failed ISSU state has been corrected.

K to O

Facility-Severity-Mnemonic

Severity-Meaning

Message

Message-Explanation

Component

Recommended-Action

LA_ACL_ERRMSG-3-ACL_EDIT_ERROR

3-Error

Failed to program modified [chars] [chars] [chars] [chars] ACL in hardware. The number of ACEs exceeded hardware limit.\n

The configuration is too large.

INVALID

You have exceeded the system limit of ACE entries. Delete the ACL first and then modify the acl by reducing number of ACEs and re-configure the ACL on the box.\n

LA_ACL_ERRMSG-3-ACL_NOT_SUPPORTED

3-Error

ACL is not supported on this interface [chars].\n

Unsupported configuration

INVALID

ACL is not supported on this interface %s.Remove the ACL from interface on IOS\n

LA_ACL_ERRMSG-3-EPC_EOMPLS_ERROR

3-Error

EPC is not supported on EOMPLS port. To recover, stop the capture from [chars] interface.\n

Unsupported configuration

INVALID

Stop the capture from %s interface..\n

LA_ACL_ERRMSG-3-OGACL_EGRESS_ERROR

3-Error

OGACL is not supported in egress dir. To recover, Delete [chars] ACL [chars] proto , correct mistake and re-create ACL.\n

Invalid configuration

INVALID

Delete ACL , correct mistake and re-create ACL.\n

LA_ACL_ERRMSG-4-UNLOADED

4-Warning

[chars] [chars] [chars] [chars] ACL on interface [chars] could not be programmed in hardware.Either number of ACLs or number of ACES in acl exceeded hardware limit. All the packets will be dropped.\n

The configuration is too large.

INVALID

You have exceeded the system limit of entries, use a simpler configuration which uses less entries.It can be either number of ACLs or number of ACES in the acl.\n

LA_ACL_ERRMSG-6-SUB_INTF_BIND_WARNING

6-Information

[chars] [chars] [chars] ACL on interface [chars] could not be programmed in hardware. VLAN is not ready in hardware. Once VLAN is ready, ACL will be attached to vlan automatically in hardware.\n

Invalid configuration.

INVALID

VLAN is not ready in hardware.Once VLAN is ready, ACL will be attached to vlan automatically in hardware. Worst case, first detach ACL from sub-interface. Configure vlan on this sub-interface if not already done and then reattach ACL \n

LA_FNF_ARGON_ERRMSG-4-OOR

4-Warning

[chars] [chars] FNF mon_id [dec] on interface [chars] could not be programmed in hardware.Either number of ACLs or number of ACES in flow monitor or netflow profile exceeded hardware limit.\n

The configuration is too large.

INVALID

You have exceeded the system limit of entries, use a simpler configuration which uses less entries. It can be either number of ACLs or number of ACES in the acl.\n

LA_L2_ERRMSG-3-MCID_EMDB_RSC_ERR

3-Error

Failed to allocate replication entry to do flooding for vlan: [dec], vp_if_id: 0x%lx - reason: [chars]

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

LA_L2_MCAST_ERRMSG-3-MCID_EMDB_RSC_ERR

3-Error

Failed to allocate replication entry for vlan: [dec], Group: [chars], vp_if_id: 0x%lx - reason: [chars]

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

LA_L2_MCAST_ERRMSG-3-MCID_RSC_ERR

3-Error

Failed to allocate mcid for vlan: [dec], Group: [chars] - reason: [chars]

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

LA_L3TUNNEL_ERRMSG-3-EXIST_ERROR

3-Error

Duplicate Tunnel config not supported\n

Same tunnel source and destination

INVALID

Delete the tunnel and move to unique src/dst combination\n

LA_L3TUNNEL_ERRMSG-3-OOR_ERROR

3-Error

Unique 16 sources and 1K Tunnels only supported\n

Too many tunnels

INVALID

Delete unwanted tunnels\n

LA_L3TUNNEL_ERRMSG-3-TUN_MOD_ERROR

3-Error

Please delete the tunnel and recreate it. Set the tunnel mode first and then configure the tunnel src and tunnel destination. Dynamic change to Tunnel mode not allowed.\n

Dynamic Tunnel mode change not allowed

INVALID

Delete Tunnel. Set the correct mode and then configure tunnel src and tunnel dst\n

LA_L3_ERRMSG-6-UNSUPPORTED_LB

6-Information

Mixed Mode of Tunnel and Normal ADJ Unsupported in LB, lbal_obj_id: 0x%x.\n

Mixed Mode of Tunnel and Normal ADJ is Unsupported in LB. We are printing the lbal_obj_id which is effected

INVALID

Normal Adj will be removed from LB if Tunnel is present. Only Tunnel adj will be present for LB

LA_QOS_ERRMSG-3-LA_QOS_SCH_BANDWIDTH_REMAINING_RATIO_IGNORED

3-Error

Ignoring Non-default[Ratio=1], Interface level Bandwidth remaining ratio([dec]) on Main-interface [chars] for policy [chars]. Reason: No support\n

Interface level(HQOS) Bandwidth remaining ratio is supported only across sub-interface on same main-interface or among main-interface with sub-interface priority propagation mode enabled and its sub-interface.

bigbang-qos

No Specific action required. However, for clarity user can consider installing different policy without Bandwidth remaining ratio in parent policy.

LA_QOS_ERRMSG-3-LA_QOS_TCAM_OOR

3-Error

No TCAM availabe to program policy [chars] on interface [chars] on [chars] direction.\n

TCAM is full on the slice where the interface is on.

bigbang-qos

Reduce the number of ACE in the policy. Remove the policy and attach again.

LA_QOS_ERRMSG-3-LA_QOS_VOQ_CGM_PROFILE_EXHAUSTED

3-Error

VOQ Congestion Mangement(CGM) profiles exhausted.\n

All the available 32 VOQ CGM Profiles have been used up and a new profile creation was attempted

bigbang-qos

Check all queueing policies for unique CGM Configuration. See if some can be combined to free some CGM Profiles

LA_QOS_ERRMSG-4-LA_QOS_SCH_PORT_SHAPER_GREATER_THAN_INTERFACE_SPEED

4-Warning

For [chars], User configured port shaper speed[[dec]] is greater than physical port speed [[dec]]. Limiting the same to physical port speed\n

User configured port shaper in H-QOS policy is higher than physical interface speed. User needs to revisit the policy.

bigbang-qos

No Specific action required. However, user needs to revisit the policy.

LA_SGACL_ERRMSG-3-SGACL_CELL_BIND_ERROR

3-Error

SGACL [chars] on cell ([dec] [dec]) is not allowed. SGACL policy of default cell is not allowed to be shared with any other cells \n

Invalid configuration.

INVALID

SGACL policy associated with default cell is non-sharable with other cells. Maintain a separate policy for default permission. \n

LA_SGACL_ERRMSG-3-SGACL_CELL_MONITOR_WARNING

3-Error

This platform supports only one counter per cell. User attached both V4 & V6 policies to cell [[dec], [dec]] but monitor mode is set to only one protocol. This may lead to inaccurate Hw-Deny, HW-Monitor cell counters. There will be no effect on functionality\n

Invalid configuration.

INVALID

Configure monitor mode for both IPv4 & IPV6 \n

LA_SGACL_ERRMSG-3-SGACL_DEFAULT_CONFIG_ERROR

3-Error

TCAM Resource Error. Default permission configuration failed. Delete default sgacl permissib ons, free up some TCAM resources and configure default permission again\n

Configuration is too big

INVALID

Delete sgacl default permissions. Free up some TCAM resources and configure default permissions again\n

LA_SGACL_ERRMSG-3-SGACL_EDIT_ERROR

3-Error

Failed to program modified [chars] [chars] [chars] [chars] ACL in hardware. The number of ACEs exceeded hardware limit.\n

The configuration is too large.

INVALID

You have exceeded the system limit of ACE entries. Delete the ACL first and then modify the acl by reducing number of ACEs and re-configure the ACL on the box.\n

LISP_AGENT_MESSAGE-3-LISP_AGENT_DB_ERROR

3-Error

DB-Error: [chars]

An internal error occurred due to which unable to update the oper DB records

ewlc-wlss-lisp

LOG_STD_ACTION

LISP_AGENT_MESSAGE-3-LISP_AGENT_MAP_REGISTER_MSG_SEND_FAIL

3-Error

Error: Failed to send [chars] to MAP Server for [chars]: %02x%02x.%02x%02x.%02x%02x

An internal error occurred due to which unable to send Map Register message to MAP server

ewlc-wlss-lisp

LOG_STD_ACTION

LISP_AGENT_MESSAGE-3-LISP_AGENT_MAP_REGISTRATION_REJECT_MSG

3-Error

Error: [chars] %02x%02x.%02x%02x.%02x%02x with rejection code [dec] - [chars], MS IP: [chars], VNID: [chars]

Received MAP Registration Reject Message

ewlc-wlss-lisp

LOG_STD_ACTION

LISP_AGENT_MESSAGE-3-LISP_AGENT_MAP_REPLY_NACK_MSG

3-Error

Error: [chars] %02x%02x.%02x%02x.%02x%02x

Received MAP reply NACK Message

ewlc-wlss-lisp

LOG_STD_ACTION

LISP_AGENT_MESSAGE-3-LISP_AGENT_MAP_REQUEST_MSG_SEND_FAIL

3-Error

Error: Failed to send [chars] to MAP Server for [chars]: %02x%02x.%02x%02x.%02x%02x

An internal error occurred due to which unable to send Map Request message to MAP server

ewlc-wlss-lisp

LOG_STD_ACTION

LISP_AGENT_MESSAGE-3-LISP_AGENT_MS_IP_ERROR

3-Error

LISP AGENT clear [chars]

Map Server msg stats not exists error

ewlc-wlss-lisp

LOG_STD_ACTION

LISP_AGENT_MESSAGE-3-LISP_AGENT_RECEIVE_ERROR_NOTIFICATION_MSG

3-Error

Error: Received reliable error notification msg with [chars] [dec]

the Error Notification message received from the MAP Server

ewlc-wlss-lisp

LOG_STD_ACTION

LISP_AGENT_MESSAGE-6-LISP_AGENT_TRANSPORT_MS_CONNECTION

6-Information

[chars] with map server IP [chars]

re-establishment of connection with map server got success

ewlc-wlss-lisp

LOG_STD_ACTION

LI_CORE-2-EGRESS_INTF_NOT_SVI

2-Critical

Not supported: egress interface ([chars]) towards LI host [chars] is not an SVI

Egress interface to reach the LI host is restricted to be an SVI

ewlc-spwifi

If this message occurs, the egress interface towards the LI host server needs to be configured as an SVI

LI_CORE-2-EGRESS_INTF_NO_GLOB_IPV6_ADDR

2-Critical

LI host address configured is IPv6, but no global IPv6 address configured on egress interface [chars]

At least one local IPv6 global/routable address is needed to reach the LI host server

ewlc-spwifi

If this message occurs, at least one IPv6 global address needs to be configured on the egress interface towards the LI host server.

LMLIB_RTU_LICENSE-1-AP_INSUFFICIENT_PERM_APCOUNT

1-Alert

APs connected exceed the permanent licenses available by [dec].

The number of APs connected is greater than the number of permanent licenses.

iosxe-fwdmgr

Purchase adder licenses to add to your existing permanent licenses.

LMLIB_RTU_LICENSE-1-AP_USAGE_EXCEEDED

1-Alert

AP-count license usage has exceeded the available AP-count by [dec].

AP-count license usage has exceeded the available AP-count.

iosxe-fwdmgr

Remove the excess APs from the controller.

LMLIB_RTU_LICENSE-1-EVAL_EXP

1-Alert

Evaluation period of [chars] license expired [dec] days ago. Purchase a permanent license.

The evaluation license has expired.

iosxe-fwdmgr

Purchase a permanent license.

LMLIB_RTU_LICENSE-1-EXCESS_AP_LIC

1-Alert

Total AP-count licenses available have exceeded the maximum supported AP-count by [dec].

The number of AP-count licenses available is greater than the maximum number of supported AP-count.

iosxe-fwdmgr

The extra AP-count licenses can be moved to another controller.

LMLIB_RTU_LICENSE-1-PRIMARY_REMOVED

1-Alert

The current stack does not support the applied AP License Count. Reconnect a Catalyst 5760 SKU running valid AP License Count within 90 days.

AIR-CT5760-HA-K9 does not support the same licensing as AIR-CT5760-HA-K9. So an AIR-CT5760-HA-K9 SKU is needed in the stack to support this licensing.

iosxe-fwdmgr

Reconnect a Catalyst 5760 SKU running valid AP License Count within 90 days.

LMLIB_RTU_LICENSE-1-RTU_DISABLED

1-Alert

Cannot proceed. Right-to-use Licensing is diabled. Switch is in Smart Licensing mode.

RTU functionality is disabled when switch in SL mode.

iosxe-fwdmgr

Enable RTU licensing with CLI: no license smart enable.

LMLIB_RTU_LICENSE-1-SKU_INCOMPAT

1-Alert

Both the switches in the stack are AIR-CT5760-HA-K9 SKUs. Replace one of the switches with another Catalyst 5760 SKU running valid AP License Count

Two AIR-CT5760-HA-K9 SKUs are not supposed to stack.

iosxe-fwdmgr

Replace the license mismatch switch with a Catalyst 5760 SKU running valid AP License Count.

LMLIB_RTU_LICENSE-1-TERM_EXP

1-Alert

Subscription term period of [chars] license expired [dec] days ago. Please renew your license.

The subscription license has expired.

iosxe-fwdmgr

Renew your subscription license.

LMLIB_RTU_LICENSE-3-FILE_ERR

3-Error

[chars]: License file update failed. Reapply the configuration.

Failed to update the license file.

iosxe-fwdmgr

Reapply the configuration.

LMLIB_RTU_LICENSE-3-FILE_READ_ERR

3-Error

[chars]: License file read failed.

Failed to read the license file.

iosxe-fwdmgr

Reapply the configuration.

LMLIB_RTU_LICENSE-4-EVAL_WARN

4-Warning

Evaluation period of [chars] license is about to expire in [dec] days. Purchase a permanent license.

The evaluation license is about to expire.

iosxe-fwdmgr

Purchase a permanent license.

LMLIB_RTU_LICENSE-4-TERM_WARN

4-Warning

Subscription term period of [chars] license is about to expire in [dec] days. Please renew your license.

The subscription license is about to expire.

iosxe-fwdmgr

Renew your subscription license.

LMLIB_RTU_LICENSE-6-AP_ADD

6-Information

[dec] adder AP-count licenses are added

AP-count licenses have been added.

iosxe-fwdmgr

More APs can be supported.

LMLIB_RTU_LICENSE-6-AP_DEL

6-Information

[dec] adder AP-count licenses are removed.

AP-count licenses have been removed.

iosxe-fwdmgr

Fewer APs are supported.

LMLIB_RTU_LICENSE-6-DISABLE_RTU

6-Information

[chars]: Right-to-use Licensing is disabled. Switch is in Smart Licensing mode.

User enables Smart Licensing.

iosxe-fwdmgr

Request image license license if needed.

LMLIB_RTU_LICENSE-6-ENABLE_RTU

6-Information

[chars]: Right-to-use Licensing is enabled. Switch is in RTU mode.

User configures RTU licensing by disabling Smart Licensing.

iosxe-fwdmgr

Configure image license and ap count license if needed.

LMLIB_RTU_LICENSE-6-FACTORY_DEFAULT_ERROR

6-Information

Factory Default License File [chars] on [chars].

An error occured when trying to create the factory default file.

iosxe-fwdmgr

Fix the issue and try again.

LMLIB_RTU_LICENSE-6-IOSD_LIC_MISMATCH

6-Information

Switch #[dec]: Current IOSd runs on [chars] license while RTU active license is [chars]. Please configure RTU license to current IOSd license.

When customer switches license mode from Smart Licensing to RTU Licensing, current IOSd license might mismatch with RTU active license.

iosxe-fwdmgr

Configure RTU license level to current IOSd license.

LMLIB_RTU_LICENSE-6-LIC_ACT

6-Information

[chars] license is activated successfully on [chars].

The license level is activated.

iosxe-fwdmgr

Reboot the switch to invoke the activated license.

LMLIB_RTU_LICENSE-6-LIC_ACTVED

6-Information

[chars] license was already activated.

The license level was already activated.

iosxe-fwdmgr

Reboot the switch to invoke the activated license.

LMLIB_RTU_LICENSE-6-LIC_CHANGE

6-Information

[chars] reboot license level changed from [chars] to [chars]. Reboot the switch to invoke the new license level.

Reboot license level has been changed.

iosxe-fwdmgr

Reboot the switch to invoke the activated license level.

LMLIB_RTU_LICENSE-6-LIC_EULA_CLEAR

6-Information

EULA for [chars] license has been cleared on [chars].

License level has been deactivated.

iosxe-fwdmgr

The end user license agreement (EULA) needs to be accepted while activating this license level.

LMLIB_RTU_LICENSE-6-LIC_EVAL_TO_PERM

6-Information

License level upgraded from [chars] [chars] to [chars]; [chars] license is in-use without reboot

A license has been upgraded to a permanent or subscription license. A reboot is NOT required for the new license level to be effective.

iosxe-fwdmgr

No action is required

LMLIB_RTU_LICENSE-6-LIC_EXPED

6-Information

[chars] evaluation license has expired; you cannot activate it again.

You cannot use an expired evaluatoin license.

iosxe-fwdmgr

Purchase a permanent license level or activate another license level.

LMLIB_RTU_LICENSE-6-LIC_IMAGE_INVALID

6-Information

Switch #[dec]: The license boot level string is invalid. Boot up with the highest activated license.

The license boot level string is invalid. The RTU highest activated license is used.

iosxe-fwdmgr

Use 'license boot level' to configure a valid license level

LMLIB_RTU_LICENSE-6-LIC_INCOMPAT

6-Information

Switch [dec] has an incompatible license level. Activate a compatible license on the switch so that the switch can join the stack.

The added switch has an incompatible license level.

iosxe-fwdmgr

Activate a new license and reboot the switch.

LMLIB_RTU_LICENSE-6-LIC_INVALID_DEACT

6-Information

[chars] license is not active on [chars]; therefore, it cannot be deactivated.

The license level is not activated.

iosxe-fwdmgr

No need to deactivate this license.

LMLIB_RTU_LICENSE-6-PLAT_INCOMPAT

6-Information

Switch [dec] has an incompatible platform level. Activate a compatible platform on the switch so that the switch can join the stack.

The added switch has an incompatible platform level.

iosxe-fwdmgr

Run in compatible scaled mode and reboot the switch.

LMRP-0-CHASFS_LOCATION_TRANSLATE

0-Emergency

Failed to translate a location to a chasfs object name because [chars]

The license manager failed to translate a location to a chasfs object name.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASFS_OBJECT_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] because [chars]

The hardware failed to create a chassis filesystem object.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASFS_OBJECT_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] not present.

A chassis filesystem object expected to be present is not. This could be due to a software defect or filesystem failure.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASFS_OBJECT_WATCH

0-Emergency

Failed to watch chassis filesystem object [chars] because [chars]

A chassis filesystem object was not watched because of the reason stated in the error message.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASFS_PROPERTY_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly created.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASFS_PROPERTY_GET

0-Emergency

Failed to read chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly read by the system.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASFS_PROPERTY_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] property [chars] not present.

A chassis filesystem object property expected to be present is not. This could be due to a software defect or filesystem failure.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASFS_PROPERTY_SET

0-Emergency

Failed to write chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property failed to write.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASSIS_STATUS

0-Emergency

Failed to get chassis hardware status because [chars]

The system failed to get the chassis hardware status.

iosxe-csl

Note the time of the error message and examine the logs for CPLD driver or hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-CHASSIS_TYPE

0-Emergency

The chassis type [chars] is invalid.

The chassis type is invalid. This could be due to a hardware defect, software defect or incorrect IDPROM content.

iosxe-csl

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-INVALID_ARGUMENT

0-Emergency

A system function was given an invalid argument.

A system function was given an invalid argument. This is due to a software defect.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-IPC_CONNECTION_INVALID

0-Emergency

An IPC connection has invalid state.

An IPC connection has an invalid state. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-IPC_CONNECT_MASTER

0-Emergency

IPC connection to the active RP failed because [chars]

IPC connection to the active RP failed. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-IPC_INITIALIZATION

0-Emergency

IPC initialization failed because [chars]

IPC initialization failed. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-MESSAGE_REGISTER

0-Emergency

Failed to register with active RP because [chars]

The active RP failed to register.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-MESSAGE_RELAY

0-Emergency

Failed to relay a message because [chars]

Failed to relay a message. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-MESSAGE_RESPONSE

0-Emergency

An invalid message response was received because [chars]

An invalid message response was received. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-MQIPC_ADVANCE

0-Emergency

Failed to advance MQIPC queue because [chars]

The MQIPC initialization failed.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-MQIPC_INITIALIZATION

0-Emergency

MQIPC initialization failed because [chars]

MQIPC initialization failed. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-PEER_TABLE

0-Emergency

A peer table initialization or maintenance function failed because [chars]

A peer table initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-PLATFORM_FAMILY_TYPE

0-Emergency

The platform family type [chars] is invalid.

The platform family type is invalid. This could be due to a hardware defect, software defect or incorrect IDPROM content.

iosxe-csl

Note the time of the error message and examine the logs for IDPROM and hardware errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-RESOLVE_FRU

0-Emergency

Failed to determine [chars] card because [chars]

The router failed to determine a FRU state.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-SERVICES_INITIALIZATION

0-Emergency

Failed to initialize general application services because [chars]

The system failed to initialize application services.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-SIGNAL_INITIALIZATION

0-Emergency

Failed to initialize signals because [chars]

The system failed to initialize signals.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-SLOTS_INITIALIZATION

0-Emergency

Failed to initialize chassis slot information because [chars]

The system failed to initialize the chassis slot information.

iosxe-csl

Note the time of the error message and examine the logs for IDPROM or software errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-SLOT_INVALID

0-Emergency

A card absolute slot number cannot be determined for this chassis type

An absolute slot number is invalid. This could be due to a software defect or incorrect IDPROM content.

iosxe-csl

Note the time of the error message and examine the logs for IDPROM or software errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-0-UIPEER_CREATE

0-Emergency

Failed to create user interface peer.

The system failed to create a user interface peer.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-3-CHASFS_OBJECT_DESTROY

3-Error

Failed to destroy chassis filesystem object [chars] because [chars]

A chassis filesystem object that should have been destroyed was not destroyed.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-3-CHASFS_PROPERTY_DESTROY

3-Error

Failed to destroy chassis filesystem proprty [chars]/[chars] because [chars]

A chassis filesystem property that should have been destroyed was not destroyed.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-3-LICENSE_SERVICE_SETUP

3-Error

Failed to setup the licensing proxy service

License Manager failed to set itself up as a proxy for licensable features.

iosxe-csl

Collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-3-PEER_INVALID

3-Error

A peer table entry has invalid state.

A peer table entry has an invalid state. This could be due to a software defect or system resource exhaustion.

iosxe-csl

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

LMRP-3-RTU_UNINITIALIZED

3-Error

RTU not yet initialized: stack enabled [dec]

License manager has not initialized RTU, but manager got RTU enable/disable request

iosxe-csl

No user action is necessary. Reloading might work

LMRP-3-THROUGHPUT_LICENSE_APPLY_FAILED

3-Error

Throughput license look-up failed due to '[chars]'

This message is to notify the user that a license look-up did not succeed because license manager process could not be contacted. This is a rare case but is due to either a crashed license daemon(licensed) or it encountered an internal error.

iosxe-csl

No user action is necessary. However, it is possible that a re-boot of the box may correct this behavior.

LMRP-3-UDI_AUTH

3-Error

Quack Unique Device Identifier authentication failed

This chassis seems to be compromised or tampered with. UDI burned on to the Quack chip and the one read from chassis EEPROM do not match. It can also be a case of either EEPROM or Quack device failure. More details about which specific field failed to match are logged in license daemon log file (licensed_R0.log).

iosxe-csl

User immediately needs to contact Cisco support. This device appears to be tampered with or is a counterfeit device or had a system failure.

LMRP-6-THROUGHPUT_LICENSE

6-Information

Throughput license [chars], throughput set to [chars]

Status indicating whether throughput license is found and the corresponding througput the CPP hardware is configured to provide.

iosxe-csl

No user action is necessary. This is an informational message indicating throughput configured.

LOADBALANCE_TRACE_MESSAGE-3-AP_SW_UPDATE_ERR_LOG_MSG

3-Error

AP SW update [chars]

AP Software Update logging

ewlc-ap

AP software update failed. ISSU image upgrade or SMU patching could be aborted. The user needs to initiate ISSU upgrade/SMU patch again. If the error occured during manual operation, operation can be initiated again

LOADBALANCE_TRACE_MESSAGE-5-AP_SW_UPDATE_LOG_MSG

5-Notice

AP SW update [chars]

AP Software Update logging

ewlc-ap

No action required

LOADBALANCE_TRACE_MESSAGE-5-LB_LOG_MSG

5-Notice

Loadbalancer Log : [chars]

Generic loadbalancer message

ewlc-ap

No action required

LOADBALANCE_TRACE_MESSAGE-5-LB_NOTICE_MSG

5-Notice

Loadbalancer : [chars]

Loadbalancer informational message

ewlc-app-infra

LOG_STD_ACTION

LUA_VM-2-INITIALIZATION

2-Critical

Cannot initialize the Lua Virtual Machine

The Lua Virtual Machine is a critical component of the shell-manager process. It is used to render responses to user commands. If this component cannot be initialized then the shell-manager will be unable to process any commands directed at the IOS-XE daemons.

iosxe-shellmgr

The shell-manager process could not be started. Check the trace log files for more details as to why the virtual machine failed to initialize correctly. This may be an out of memory condition so rebooting the chassis may resolve the problem.

MAB-5-FAIL

5-Notice

Authentication failed for client ([chars]) with reason ([chars]) on Interface [chars] AuditSessionID [chars]

MAB Authentication was unsuccessful.

polaris-smd

No action is required.

MAB-5-RESULT_OVERRIDE

5-Notice

Authentication result overridden for client ([chars]) on Interface [chars] AuditSessionID [chars]

Authentication result was overridden

polaris-smd

No action is required.

MAB-5-SUCCESS

5-Notice

Authentication successful for client ([chars]) on Interface [chars] AuditSessionID [chars]

MAB Authentication was successful.

polaris-smd

No action is required.

MATM-3-CONSISTENCY_CHECK_RESULT

3-Error

No Inconsistency detected for Address %02x:%02x:%02x:%02x:%02x:%02x, vlan [dec]

Consistency checker execution completed

polaris-l2

No Inconsistency detected

MATM-3-HWERROR

3-Error

Hardware [chars] failed

A hardware API access error message occurred.

polaris-l2

Find out more about the error by using the commands show platform matm recon_state and show tech-support and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

MATM-3-INVALID_EVENT

3-Error

An invalid event :[dec] received in [chars], expected event:[dec]

MATM feature received invalid event on it's event handler

polaris-l2

The condition is being recovered, no action is required

MATM-3-MAC_INCONSISTENCY

3-Error

Inconsistency detected: Address :%02x:%02x:%02x:%02x:%02x:%02x, Vlan [dec]

There is a difference between mac address entry in software and hardware

polaris-l2

Try clearing the mac or run recovery mechanism

MATM-3-MAX_ENTRIES

3-Error

The maximum number of MAC addresses has been reached:[dec]

The maximum number of MAC entries that can be programmed has been reached.

polaris-l2

New MAC addresses will not be learned. Stop any redundant MAC incrementing traffic for extra streams.

MATM-3-RECONCILIATION

3-Error

Reconciliation post switchover failed : [chars]

Consistency check across modules shows inconsistency in data.

polaris-l2

Find out more about the error by using the commands show platform matm recon_state and show tech-support and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

MCAST_ERROR_MESSAGE-3-MCAST_AVL_DB_MISMATCH

3-Error

DB Mismatch: [chars]

Previous joins and leaves have corrupted the database.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_CLIENT_DATA_ERR

3-Error

Client %02X%02X.%02X%02X.%02X%02X multicast data is NULL.

Internal multicast database client entry should contain multicast data when a multicast join request comes from below service layer

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_CLIENT_ENTRY_ERR

3-Error

Client %02X%02X.%02X%02X.%02X%02X does not exist in internal database.

internal multicast database must contain the client entry when a multicast join request comes from below service layer

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_CLNT_ENT_ERR

3-Error

(S,G) count is zero whereas multicast data of client %02X%02X.%02X%02X.%02X%02X is not NULL

when client disassociates (S,G) count is zero but client's multicast entry is not NULL.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_CLTMAC_LOOKUP_ERR

3-Error

Mismatch between two database while [chars] mgid = [dec] client mac = %02X%02X.%02X%02X.%02X%02X

Two different databases have different values for the client. Multicast functionality will be affected due to mismatch of database values.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_DETELE_AVL_MGID

3-Error

Deletion of mgid [dec] from internal multicast databases failed

Mgid entry deletion from the internal database fails

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_GRP_JOIN_LEAVE_FAILED

3-Error

[chars] for client %02X%02X.%02X%02X.%02X%02X multicast group [chars], mgid [dec]

Failure occurred while handling multicast group join or leave.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_INSERT_MGID_FAIL

3-Error

insertion of mgid into database failed for some unknown reason - for source [chars] - group [chars] - vlan [dec]

Internal multicast database corrupted.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_IP_MISMATCH

3-Error

[chars] IP Value already inserted for mgid [dec] mismatches. saved value [chars] expected [chars]

the IP of the stored database and incoming database mismatches

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_MGID_CLIENT_TREE_DESTROY_FAIL

3-Error

Mgid [dec] client tree destroy in internal multicast database failed

Mgid client tree destroy in internal database failed

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_MGID_CLIENT_TREE_WALK_FAIL

3-Error

Mgid [dec] client tree walk in internal multicast database failed

Mgid client tree walk in internal database failed

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_MGID_DATA_MISMATCH

3-Error

There is some data mismatch between two databases for mgid [dec].

some database in multicast code is having unexpected null data

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_MGID_MISMATCH

3-Error

mgid value mismatch in database value found [dec] - expected mgid [dec]

the stored mgid value in the database is not same as expected.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_MGID_NULL_DATA

3-Error

multicast database is having unexpected [chars] NULL value for mgid [dec]

some database in multicast code is having unexpected null data

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_MGID_SGV_DATA_MISMATCH

3-Error

There is some data mismatch between two databases for source [chars] group [chars] vlan [dec] mgid [dec]

some database in multicast code is having unexpected null data

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_MOBILITY_HANDOFF_FAILED

3-Error

[chars] [chars] mobility multicast handoff for client %02X%02X.%02X%02X.%02X%02X

Failure occurred while handling mobility multicast handoff.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_SG_MAXMGID_ERR

3-Error

Multicast group count [dec] is greater than maximum mgids [dec] per client for client %02X%02X.%02X%02X.%02X%02X

This and further new mgid entries for this client will be ignored Multicast functionality will be affected for those mgids.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_SG_NONZERO_ERR

3-Error

[chars] (S,G) count [dec] is greater than zero whereas client %02X%02X.%02X%02X.%02X%02X multicast data is NULL

Two different databases have different values for the client. Multicast functionality will be affected due to mismatch of database values.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-MCAST_SPAM_UPDATE_FAILED

3-Error

[chars] for mgid type [dec], client %02X%02X.%02X%02X.%02X%02X multicast group info [chars] to AP %02X%02X.%02X%02X.%02X%02X

Failure occurred while sending multicast info to AP.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-3-TASK_CREATE_ERR

3-Error

ERROR: Failed to create client-multicast library

An internal error occurred due to which the client multicast subsystem could not be initialized. APs may not be able to join the controller.

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-4-MCAST_MOM_NOT_CONFIGURED_ON_MOM_ONLY_PLATFORM

4-Warning

Multicast-over-Multicast (wireless multicast <ipv4Addr>/ipv6 <ipv6Addr>) is not configured on Multicast-over-Multicast Only platform. Wireless multicast will not work until MOM is configured

Wireless multicast is configured without MOM on MOM-Only platform

ewlc-multicast

LOG_STD_ACTION

MCAST_ERROR_MESSAGE-6-MCAST_MOM_CONFIG_CHANGE

6-Information

Capwap multicast mode [chars] [chars]. IPv4 [[chars]:[chars]] and IPv6 [[chars]:[chars]] with Wireless multicast status [chars]. [chars]

Wireless capwap multicast mode changed

ewlc-multicast

LOG_STD_ACTION

MCG_APMGR_MESSAGE-3-APMGR_ERROR

3-Error

Error : [chars]

APMGR error

mcg-ap

LOG_STD_ACTION

MCG_APMGR_MESSAGE-5-AP_DISJOIN

5-Notice

AP Name : [chars], MAC : [chars], Session : [chars]

AP disjoin information

mcg-ap

LOG_STD_NO_ACTION

MCG_APMGR_MESSAGE-5-AP_JOIN

5-Notice

AP Name : [chars], MAC : [chars], Session : [chars]

AP Join information

mcg-ap

LOG_STD_NO_ACTION

MCP_SYS-0-ASSERTION_FAILED

0-Emergency

Assertion failed: [chars]

An internal state consistency check failed.Correct operation cannot be guaranteed, and the system has been halted.

INVALID

LOG_STD_ACTION

MDNS_SYSLOG-3-EXCESS_SERVICE

3-Error

number of responses([dec]) for query ([chars]) is limited to ([dec]) due to query response threshold

An MDNS Service Query resulted in too many services in the response, user experience for MDNS may be suboptimal. This may also consume more CPU cycles

mdns-binos

Check the service policy configuration and consider moving to a more restrictive location if the problem persists

MDNS_SYSLOG-3-EXCESS_SERVICE_WIDE_AREA_BONJOUR

3-Error

Number of services in the response ([dec]) for query [chars] has exceeded threshold [dec]

An MDNS Service Query resulted in too many services in the response, user experience for MDNS may be suboptimal and may take up more CPU

mdns-binos

re-check the service policy on the Wide area bonjour side and Controller. Move to more restrictive location filter if problem persists

MDR-3-NODE_ISSU_SIP_WAIT

3-Error

Could not wait for [chars] to complete Minimal Disruptive Restart

An unexpected error has occured where the specified linecard was performing a Minimal Disruptive Restart using node ISSU, however Minimal Disruptive Restart did not complete before the next operation needed to commence. This linecard was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-3-NODE_ISSU_SPA_WAIT

3-Error

Could not wait for [chars] in [chars] to complete Minimal Disruptive Restart

An unexpected error has occured where the specified module was performing a Minimal Disruptive Restart using node ISSU, however Minimal Disruptive Restart did not complete before the next operation needed to commence. This module was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-3-NO_ACTIVE_ESP

3-Error

No active ESP was found when initiating Minimal Disruptive Restart

An unexpected error has occured where no active ESP was found to continue forwarinding traffic during the Minimal Disruptive Restart. All requested linecards and or modules were reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or linecard OIR.

MDR-3-NO_SPAS_IN_SIP

3-Error

No Minimal Disruptive Restart compatible SPAs found in [chars]

An unexpected error has occured where the specified linecard that was to undergo Minimal Disruptive Restart did not contain any compatible SPAs. This linecard was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-3-READ_COMPAT_INFO

3-Error

Failed to read valid Minimal Disruptive Restart compatibility information for [chars]

An unexpected error has occured where either modules in or the specified linecard itself, was to undergo Minimal Disruptive Restart however valid compatibility information could not be read prior to commencing Minimal Disruptive Restart. If the linecard itself was to go through Minimal Disruptive Restart, it and the modules within it were reset as normal. If only modules were going through Minimal Disruptuve Restart, all modules were reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors.

MDR-3-READ_SIP_RESET

3-Error

Failed to read a valid Minimal Disruptive Restart reset value for [chars]

An unexpected error has occured where either modules in or the specified linecard itself, was to undergo Minimal Disruptive Restart however a valid SIP reset value could not be read. This linecard was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors.

MDR-3-RESTART_FAILED

3-Error

Failed to perform Minimal Disruptive Restart on [chars]

An unexpected error has occured where the specified linecard or module failed to undergo a Minimal Disruptive Restart. This linecard or module was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors.

MDR-3-SIP_OFFLINE

3-Error

[chars] is not online to perform Minimal Disruptive Restart

An unexpected error has occured where the specified linecard was to undergo Minimal Disruptive Restart however the linecard was not found to be online. The linecard was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or linecard OIR.

MDR-3-SOFTWARE_TRANSFER

3-Error

Failed to receive upgrade software for [chars]

An unexpected error has occured where the specified linecard was to undergo Minimal Disruptive Restart however the linecard was not able to receive the upgrade software prior to commencing Minimal Disruptive Restart. The linecard was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors.

MDR-3-SPA_BAY_INVALID

3-Error

Could not perform Minimal Disruptive Restart on invalid [chars] in [chars]

An unexpected error has occured where the specified module was to undergo Minimal Disruptive Restart however the module was invalid.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-3-SPA_IS_NOT_READY

3-Error

[chars] in [chars] is not ready to perform Minimal Disruptive Restart

An unexpected error has occured where the specified module was to undergo Minimal Disruptive Restart however the module was not found to be ready. The module was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-3-SPA_NOT_FOUND

3-Error

[chars] in [chars] could not be found to perform Minimal Disruptive Restart

An unexpected error has occured where the specified module was to undergo Minimal Disruptive Restart however the module was not found. The module was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-3-SPA_OFFLINE

3-Error

[chars] in [chars] is not online to perform Minimal Disruptive Restart

An unexpected error has occured where the specified module was to undergo Minimal Disruptive Restart however the module was not found to be online. The module was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-3-SPA_TYPE_MISMATCH

3-Error

Could not perform Minimal Disruptive Restart on [chars] in [chars] due to a SPA type mismatch

An unexpected error has occured where the specified module was to undergo Minimal Disruptive Restart however the module's SPA type was found to be different to what was expected. The module was reset as normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-3-SPA_WAS_NOT_READY

3-Error

[chars] in [chars] was not ready to perform Minimal Disruptive Restart

An unexpected error has occured where the specified module was to undergo Minimal Disruptive Restart however the module was not found to be ready at the time it was checked. The module was reset was normal.

iosxe-binos-utils

Review the IOSd, RP and CC chassis manager logs for errors or module OIR.

MDR-5-CARD_RESTART

5-Notice

Minimal Disruptive Restart [chars] to acquire provisioned software

The FRU specified was not running the currently provisioned software, which it will acquire on Minimal Disruptive Restart.

iosxe-binos-utils

No user action is necessary. This message indicates the system is functioning normally and is provided for informational purposes only.

MDR-5-SIP_UNSUPPORTED

5-Notice

[chars] does not support Minimal Disruptive Restart

The linecard specified was restarted during an Minimal Disruptive Restart, however it does not support this feature either because of its type or there are no SPA's that support Minimal Disruptive Restart inserted. This linecard was reset as normal.

iosxe-binos-utils

No user action is necessary.

MDR-5-SPA_UNSUPPORTED

5-Notice

[chars] does not support Minimal Disruptive Restart

The module specified was restarted during an Minimal Disruptive Restart, however it does not support this feature either because of its type or software version. This module was reset as normal.

iosxe-binos-utils

No user action is necessary.

MDT_CONNECTION-6-STATE_CHANGED

6-Information

Connection state changed (id [chars] - [chars]): [chars]

The connection state has been changed.

polaris-mdt-infra

Notification for connection state changed. No action required.

MDT_SUBSCRIPTION-4-EXCEEDED_ACTIVE_SUB_LIMIT

4-Warning

Active subscription limit exceeded (stream [chars], id [chars], client [chars]): [chars]

The specified subcription will not be connected due to exceeding the maximum number of active subscriptions on this platform.

polaris-mdt-infra

Reduce the number of active subscriptions by either removing configured subscriptions or terminating dynamic subscriptions that are not needed.

MDT_SUBSCRIPTION-4-INVALID_ARGUMENTS

4-Warning

Subscription creation failed (stream [chars], id [chars], client [chars]): [chars]

The value of the given parameter is invalid or not specified.

polaris-mdt-infra

Correct the invalid parameter and try the subscription again.

MDT_SUBSCRIPTION-4-NOT_SUPPORTED

4-Warning

Subscription creation failed (stream [chars], id [chars], client [chars]): [chars]

The value of the given parameter is not supported.

polaris-mdt-infra

Try the subscription again with a supported value.

MDT_SUBSCRIPTION-4-OUTSIDE_LIMIT

4-Warning

Subscription creation failed (stream [chars], id [chars], client [chars]): [chars]

The value of the parameter is outside of the allowable range.

polaris-mdt-infra

Try the subscription again with a value within the allowable range.

MDT_SUBSCRIPTION-4-RESUMED

4-Warning

Subscription resumed (stream [chars], id [chars], client [chars]): [chars]

The specified subscription was resumed from run-time error.

polaris-mdt-infra

Try to slow down the data source or check if the connection is stable.

MDT_SUBSCRIPTION-4-TERMINATED

4-Warning

Subscription terminated (stream [chars], id [chars], filter [chars], client [chars]): [chars]

The specified subscription was terminated due to run-time error.

polaris-mdt-infra

Try the subscription again

MDT_SUBSCRIPTION-4-XPATH_INVALID

4-Warning

Subscription creation failed (stream [chars], id [chars], client [chars]): [chars]

The specified XPath filter is invalid.

polaris-mdt-infra

Correct the XPath filter and try the subscription again.

MERAKI_MGRD-3-MERAKI_INTFC_SETUP_ERR

3-Error

Meraki interface setup error: [dec]

Initial meraki interface setup failed - cannot bringup config updater

polaris-aurora

Retry reconfiguring service meraki connect

MERAKI_MGRD-5-CONFIG_MONITOR_ERR

5-Notice

Config Monitor ERR: [chars]

Config monitor err message

polaris-aurora

No action is required

MERAKI_MGRD-5-CONFIG_MONITOR_NOTIF

5-Notice

Config Monitor: [chars]

Config monitor message

polaris-aurora

No action is required

MERAKI_MGRD-5-CONFIG_UPDATER_ERR

5-Notice

Config Updater ERR: [chars]

Config Updater err message

polaris-aurora

No action is required

MERAKI_MGRD-5-CONFIG_UPDATER_NOTIF

5-Notice

Config Updater: [chars]

Config Updater message

polaris-aurora

No action is required

MERAKI_MGRD-5-CURL_FETCH_ERR

5-Notice

Curl Fetch ERR: [chars]

Curl Fetch error message

polaris-aurora

No action is required

MERAKI_MGRD-5-MERAKI_FSM_START_FAILED

5-Notice

Meraki FSM failed to start

Meraki mgrd FSM failed to start

polaris-aurora

No action is required

MERAKI_MGRD-5-MERAKI_RESET_NOTIFICATION

5-Notice

: Reset Notification [chars]

Reset recovery message

polaris-aurora

No action is required

MERAKI_MGRD-5-MERAKI_RESET_RECOVERY

5-Notice

: Reset recovery [chars]

Reset recovery message

polaris-aurora

No action is required

MERAKI_MGRD-5-PRI_TUNNEL_STATE

5-Notice

Primary Tunnel State: [chars]

Primary tunnel state change notification

polaris-aurora

No action is required

MERAKI_MGRD-5-SEC_TUNNEL_STATE

5-Notice

Secondary Tunnel State: [chars]

Secondary tunnel state change notification

polaris-aurora

No action is required

MERAKI_NCMD-5-NODE_CERT_RENEW_STATE

5-Notice

Node Cert Renew State: [chars]

Node Cert renew state change notification

polaris-aurora

No action is required

MERAKI_NCMD-5-NODE_CERT_STATE

5-Notice

Node Cert State: [chars]

Node Cert state change notification

polaris-aurora

No action is required

MERAKI_NCMD-5-NODE_CLOUD_ID_STATE

5-Notice

Node Cloud_ID State: [chars]

Node Cloud_ID state change notification

polaris-aurora

No action is required

MERAKI_NCMD-5-NODE_TOKEN_STATE

5-Notice

Node Token State: [chars]

Node Token state change notification

polaris-aurora

No action is required

MESH_DB_TRACE_MESSAGE-3-EWLC_MESH_DB_EXEC_MSG

3-Error

%% Error: [chars]

Improper arguments or config

iosxe-binos-utils

Arguments to be changed

MESH_DB_TRACE_MESSAGE-6-EWLC_MESH_DB_INFO_MSG

6-Information

%% Info: [chars]

Info level logs

iosxe-binos-utils

No action required

MESH_TRACE_MESSAGE-3-EWLC_MESH_AP_DISCONNECT_MSG

3-Error

%% Error: [chars]

Failed to Disconnect AP for Mesh config changes

iosxe-binos-utils

Reboot the AP for the mesh configs to be applied

MESH_TRACE_MESSAGE-3-EWLC_MESH_AP_RESET_MSG

3-Error

%% Error: [chars]

Failed to reboot AP for Mesh config changes

iosxe-binos-utils

Reboot the AP for the mesh configs to be applied

MESH_TRACE_MESSAGE-3-EWLC_MESH_EXEC_MSG

3-Error

%% Error: [chars]

Improper arguments or config

iosxe-binos-utils

Arguments to be changed

MESH_TRACE_MESSAGE-3-EWLC_MESH_PROFILE_CHANGE_MSG

3-Error

%% Error: [chars]

Mesh profile change for AP did not get Applied

iosxe-binos-utils

Reboot the AP for the mesh configs to be applied

MESH_TRACE_MESSAGE-4-EWLC_MESH_DCA_INTERVAL_MSG

4-Warning

DCA interval is too long. Configure it to 10min to make sure algorithm will run

The DCA algorithm might not run during that channel update period

iosxe-binos-utils

Configure DCA interval to a 10min period to make sure that the algorithm will run

ME_APMGR_TRACE_MESSAGE-2-EWC_APMGR_CFG_SYNC_FAIL

2-Critical

Failed to synchronize configuration to EWC-capable APs on the network

Failed to synchronize configuration to EWC-capable APs on the network

ewcap-image

A switchover to the standby followed by reconfiguration is recommended.

ME_APMGR_TRACE_MESSAGE-6-EWC_APMGR_RESET

6-Information

AP Event: Controller Image Download is successful, reset AP mac [chars]

Controller Image Download is successful, reset AP

ewcap-image

LOG_STD_NO_ACTION

MMIF_LOG-2-WLAN_CRIT_ERR

2-Critical

WLAN Error : [chars]

Critical issue seen with WLAN config. Make a note of any recent changes made to the network or the device configuration which may have triggered this and proceed to the suggested action.

ewlc-mobility

Copy the error message exactly as it appears on the console or in the system log. Open a case with the Technical Assistance Center via the Internet http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information. It is suggested to collect archive traces and live process core to analyse the error.

MMIF_LOG-3-BUFF_ALLOC_FAILED

3-Error

Failed to allocate memory for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MMIF_LOG-3-BUFF_DEALLOC_FAILED

3-Error

Failed to deallocate memory for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MMIF_LOG-3-MSG_PAYLOAD_ALLOCATE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot allocate [chars] for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MMIF_LOG-3-MSG_PAYLOAD_BUILD_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot build [chars] for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MMIF_LOG-3-MSG_PAYLOAD_BUILD_GENERAL_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Failed to build [chars]: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MMIF_LOG-3-MSG_PAYLOAD_PROCESS_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot process [chars] for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MMIF_LOG-3-MSG_PAYLOAD_RECEIVE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: [chars] received is missing payload [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MMIF_LOG-4-ANCHOR_RESP_LOCAL_DELETE

4-Warning

Export anchor required but internal error occurred (e.g.: out of resources), sending export anchor deny for: Wlan-Profile: [chars], Policy Profile: [chars], client mac: %02x:%02x:%02x:%02x:%02x:%02x

Export anchor required but internal error occurred (e.g.: out of resources)

ewlc-guest

If this message occurs, it implies that internal error occurred and needs further debugging.

MMIF_LOG-4-ANCHOR_RESP_PROFILE_MISMATCH

4-Warning

Export anchor required but config is incorrect, sending export anchor deny mismatch for: Wlan-Profile: [chars], Policy Profile: [chars], client mac: %02x:%02x:%02x:%02x:%02x:%02x

Export anchor required but config is incorrect: sending export anchor deny mismatch

ewlc-guest

If this message occurs, it implies that configuration should be checked for wlan and policy profile

MMIF_LOG-7-MSG_PAYLOAD_SIZE_ERROR

7-Debug

The payload size has exceeded the limit. [chars]

Available buffer cannot hold IPV6 NDP pkt payload.

ewlc-mobility

LOG_STD_NO_ACTION

MM_APLIST_LOG-3-APENTRY_DEL_FAILED

3-Error

Could not delete an AP from the AP list.

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_APLIST_LOG-3-INVALID_APLISTUPD_RECVD

3-Error

Received an invalid ap-list-update from [chars]. Entries: [dec], Expected: [dec]. [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_APLIST_LOG-3-MSG_PAYLOAD_RECEIVE_ERROR

3-Error

[chars] message received is missing payload [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_APLIST_LOG-4-APENTRY_ADD_FAILED

4-Warning

Unable to create an ApList entry for AP %02x%02x.%02x%02x.%02x%02x. ApList table is full

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-0-MOBILITY_TASK_FAILED_TO_START

0-Emergency

[chars] task could not be started. The system will be rebooted

LOG_EXPL_SYSERR

ewlc-mobility

The mobility services failed to start correctly

MM_INFRA_LOG-0-MSG_RECV_FAILED

0-Emergency

[chars]: msg revd failed

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-0-QUEUE_CREATE_FAILED

0-Emergency

[chars]: queue creation failed

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-1-MOBILITYUSER_STATECREATE_FAILED

1-Alert

Unable to create mobility state for user [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-1-USER_NOT_ALLOWED

1-Alert

Unable to allow user [chars] into the system. [chars]

Unable to allow the user into the system for the reported reason

ewlc-mobility

LOG_STD_NO_ACTION

MM_INFRA_LOG-2-INIT_FAILED

2-Critical

Error while initializing mobility daemon. [chars]

Error while initializing mobility daemon

ewlc-mobility

If this error is seen, it is recommended that the controller's mobility configuration be redone as it may have been lost. If you still require assistance, open a case with the Technical Assistance Center via the Internet or contact your Cisco technical support

MM_INFRA_LOG-3-BUFF_ALLOC_FAILED

3-Error

Failed to allocate memory for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-BUFF_DEALLOC_FAILED

3-Error

Failed to deallocate memory for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-CONFIGDOWNLOAD_FAILED

3-Error

Failed to send a config download [chars] paket to [dec].[dec].[dec].[dec]

Failed to send a configdownload packet

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-DGRAM_SEND_FAILED

3-Error

%02x%02x.%02x%02x.%02x%02x: Unable to send [chars] to [chars].

Unable to send a mobility packet

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-INVALID_PKT_RECVD

3-Error

Received an invalid packet from source endpoint: [chars]. [chars]

LOG_EXPL_SYSERR

ewlc-mobility

Please check mobility configuration to see if it needs correction. If the problem persists, open a case with the TAC via the Internet action, or contact your Cisco technical support representative and provide the representative with the gathered information.

MM_INFRA_LOG-3-MSG_PAYLOAD_ALLOCATE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot allocate [chars] for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PAYLOAD_BUILD_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot build [chars] for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PAYLOAD_BUILD_GENERAL_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Failed to build [chars]: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PAYLOAD_DECODE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: [chars] cannot decode mobility payload/s for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PAYLOAD_ENCODE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: [chars] cannot encode mobility payload/s for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PAYLOAD_PROCESS_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot process [chars] for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PAYLOAD_RECEIVE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: [chars] received is missing payload [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PROC_FAILED

3-Error

%02x%02x.%02x%02x.%02x%02x: Unable to process the received mobility message [chars] from [chars]. reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PROC_FAILED_GROUP_NAME_HASH

3-Error

Pkt group name hash: [chars] Peer group name hash: [chars] [chars]. reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_PROC_FAILED_MAC_ADDR

3-Error

Pkt MAC: %02x%02x.%02x%02x.%02x%02x Peer MAC: %02x%02x.%02x%02x.%02x%02x [chars]. reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-MSG_TIMER_ERROR

3-Error

Timer error: failed to [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-RECV_FAILED

3-Error

Unable to receive mobility message [chars] from [chars]. reason: [chars]

Unable to receive a mobility packet

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-3-SEND_FAILED

3-Error

%02x%02x.%02x%02x.%02x%02x: Unable to send [chars] to [chars]. Reason: [chars].

Unable to send a mobility packet

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-4-MOBILITY_OUTGOING_MSG_ERROR

4-Warning

Invalid outgoing msg

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_INFRA_LOG-7-MSG_PAYLOAD_SIZE_ERROR

7-Debug

The payload size has exceeded the limit. [chars]

Available buffer cannot hold IPV6 NDP pkt payload.

ewlc-mobility

LOG_STD_NO_ACTION

MM_INFRA_LOG-7-MSG_PROC_UNEXISTING_CLIENT

7-Debug

%02x%02x.%02x%02x.%02x%02x: Unable to process the received mobility message [chars] from [chars]. reason: [chars]

LOG_STD_NO_ACTION

ewlc-mobility

LOG_STD_NO_ACTION

MM_LOG-2-MAX_SUPPORTED_CLIENTS_90PCT_EXCEEDED

2-Critical

90%% ([dec]) of maximum supported number of joined client [dec] exceeded

Exceeded 90% of maximum supported client join limit

ewlc-mobility

LOG_STD_NO_ACTION

MM_LOG-2-MAX_SUPPORTED_CLIENTS_EXCEEDED

2-Critical

Maximum supported number of joined clients [dec] exceeded

Maximum supported number of joined clients exceeded.

ewlc-mobility

LOG_STD_NO_ACTION

MM_LOG-3-ANCHOR_GENERIC_ERR

3-Error

Anchor: [chars]. client mac: %02x:%02x:%02x:%02x:%02x:%02x

Anchor has detected and error.

ewlc-guest

LOG_STD_RECUR_ACTION

MM_LOG-3-BUFF_ALLOC_FAILED

3-Error

Failed to allocate memory for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-BUFF_DEALLOC_FAILED

3-Error

Failed to deallocate memory for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-MIP_READ_ERROR

3-Error

[chars]. Encountered memory error, please report the error if you experience a crash.

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-MSG_PAYLOAD_ALLOCATE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot allocate [chars] for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-MSG_PAYLOAD_BUILD_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot build [chars] for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-MSG_PAYLOAD_BUILD_GENERAL_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Failed to build [chars]: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-MSG_PAYLOAD_ENCODE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: cannot encode mobility payload/s for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-MSG_PAYLOAD_PROCESS_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: Cannot process [chars] for [chars]. Reason: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-MSG_PAYLOAD_RECEIVE_ERROR

3-Error

%02x%02x.%02x%02x.%02x%02x: [chars] received is missing payload [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-3-MSG_TIMER_ERROR

3-Error

[chars] Timer: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_LOG-4-EXPORT_ANCHOR_DENY

4-Warning

Export anchor required, but received export anchor deny for: WLAN Profile: [chars], Client MAC: %02x:%02x:%02x:%02x:%02x:%02x, Error: [chars]

Export anchor required: received export anchor deny

ewlc-guest

If this message occurs, depending on the error code appropriate action is required.

MM_LOG-4-RETRIES_FAILED

4-Warning

MAC: %02x:%02x:%02x:%02x:%02x:%02x: All retries of [chars] (XID: [dec]) to [chars] have been exhausted

All retries for packet are exhaused

ewlc-mobility

LOG_STD_ACTION

MM_LOG-6-ANCHOR_GENERIC_INFO

6-Information

Anchor: [chars]. client mac: %02x:%02x:%02x:%02x:%02x:%02x

Anchor has detected a protocol issue and recovered.

ewlc-guest

LOG_STD_NO_ACTION

MM_LOG-6-MAX_CLIENTS_PER_WLAN_REACHED

6-Information

Maximum number of Clients on wlan [chars] with Limit: [dec] Reached

Maximum number of Clients per wlan Join Limit Reached.

ewlc-mobility

LOG_STD_NO_ACTION

MM_LOG-6-MAX_CLIENTS_THRESHOLD_REACHED

6-Information

Maximum number of Client Join Limit: [dec] Reached

Maximum number of Client Join Limit Reached.

ewlc-mobility

LOG_STD_NO_ACTION

MM_LOG-6-MM_EXPORT_ANCHOR_FULL

6-Information

Export Anchor not responding, back off condition set (Client MAC: %02x:%02x:%02x:%02x:%02x:%02x, AnchorIP: [chars])

LOG_EXPL_SYSINFO

ewlc-guest

LOG_STD_NO_ACTION

MM_LOG-6-WLAN_CLIENT_LIMIT

6-Information

Client limit reached on [chars]. Denied client mac: %02x:%02x:%02x:%02x:%02x:%02x

Client limit reached on wlan on anchor.

ewlc-mobility

LOG_STD_ACTION

MM_LOG-7-EXPORT_ANCHORS_DOWN

7-Debug

MAC:%02x:%02x:%02x:%02x:%02x:%02x: All Export-Anchors are down.

All Export-Anchors are down.

ewlc-guest

If this message occurs, it implies that there is loss of network connectivity between the WLC and the export anchors for this guest LAN. It is recommended that the network and the status of the anchors be debugged for connectivity issues.

MM_LOG-7-MSG_PAYLOAD_SIZE_ERROR

7-Debug

The payload size has exceeded the limit. [chars]

Available buffer cannot hold IPV6 NDP pkt payload.

ewlc-mobility

LOG_STD_NO_ACTION

MM_NODE_LOG-0-MULTICAST_GROUP_IP_SET_ERROR

0-Emergency

Error in [chars] while setting local mobility group multicast IP address [dec].[dec].[dec].[dec]. Please disable mobility multicast-mode if this error continues

Mobility is unable to use multicast for messaging

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-1-ANCHORS_DOWN

1-Alert

All Export-Anchors are down

All Export-Anchors are down on WLAN

ewlc-guest

If this message occurs, it implies that there is loss of network connectivity between the WLC and the export anchors for this WLAN. It is recommended that the network and the status of the anchors be debugged for connectivity issues.

MM_NODE_LOG-1-KEEP_ALIVE

1-Alert

Mobility [chars] tunnel to peer [chars] changed state to [chars]

Mobility tunnel state change message.

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-3-BUFF_ALLOC_FAILED

3-Error

Failed to allocate memory for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-BUFF_DEALLOC_FAILED

3-Error

Failed to deallocate memory for [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-INTFCHANGE_REGISTER_FAILED

3-Error

Failed to register callback for interface changes

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-3-INVALID_NONCE_RECVD

3-Error

Received an invalid Nonce-update from [chars]. [chars].

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-INVALID_PMKDEL_RECVD

3-Error

Received PMK-delete from [chars] with no Station address TLV.

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-INVALID_PMKUPD_RECVD

3-Error

Received an invalid PMK-update from [chars]. [chars].

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-MEMBER_ADD_FAILED

3-Error

Could not add Mobility Member. Reason: [chars], IP: [chars]

Could not add Mobility Member for the given reason.

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-MEMBER_DEL_FAILED

3-Error

Could not delete Mobility Member. Reason: [chars], IP: [chars]

Mobility Member deletion from the list failed

ewlc-mobility

Please check if the mobility member to be deleted exists

MM_NODE_LOG-3-MEMBER_UPDATE_FAILED

3-Error

Could not update Mobility Member. Reason: [chars], IP: [chars]

Could not update Mobility Member for the given reason.

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-MSG_PAYLOAD_RECEIVE_ERROR

3-Error

[chars] message received is missing payload [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-MULTICAST_GROUP_SEND_ERROR

3-Error

Unable to send multicast mobility message. [chars]

Mobility is unable to use multicast for messaging

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-3-PEER_PING_FAILED

3-Error

Mobility ping to [chars] rejected. [chars]

Mobility ping rejected

ewlc-mobility

Please check the ping command issued

MM_NODE_LOG-3-PEER_PING_VERSION_UNKNOWN

3-Error

Mobility ping to [chars] rejected. [chars]

Mobility ping version unknown

ewlc-mobility

Please check if the controllers in the mobility list can interOp and

MM_NODE_LOG-3-PING_DROPPED

3-Error

Drop [chars] ping from [chars]. [chars]

Mobility ping response Dropped

ewlc-mobility

LOG_STD_NO_ACTION

MM_NODE_LOG-3-PING_SEND_FAILED

3-Error

Failed to send a [chars] ping to [chars] . Reason: [chars].

Failed to send a ping

ewlc-mobility

Please check mobility configuration to see if it needs correction

MM_NODE_LOG-3-SOCK_INVALID_MULTICAST_ADDRESS

3-Error

Mobility group local multicast address has invalid setting: [dec].[dec].[dec].[dec]. Resetting it to 0.0.0.0 and disabling mobility multicast

Mobility multicast group address configuration was found invalid. It may have been corrupted during config transfer

ewlc-mobility

Configure the address again by using cmd: config mobility multicast-mode enable multicast_address

MM_NODE_LOG-3-SOCK_OPER_FAILED

3-Error

Failed to [chars] a socket. [chars]

A Socket operation is failed

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-3-SOCK_SET_ADDRESS_OPTION_FAILED

3-Error

Failed to [chars] a socket. Reason: [chars].

A Socket operation is failed. Multicast mode will not work for mobility

ewlc-mobility

Try setting the local group multicast address again. If the same error is seen, disable the multicast-mode for mobility and

MM_NODE_LOG-3-SYSTEM_IP

3-Error

Peer IP conflicts with system IP [chars]

Peer Ip is conflicting with System Management Ip.

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-3-SYSTEM_MAC

3-Error

Member [chars] is configured with a MAC that conflicts with system mobility MAC addres (%02x%02x.%02x%02x.%02x%02x)

Peer MAC is conflicting with System Mobility MAC.

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-4-DTLS_HANDSHAKE_FAIL

4-Warning

[chars] handshake failed for [chars] HB is down, need to re-initiate DTLS handshake

Error during DTLS handshake

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-4-HB_MEMBER_ADD_BY_IP_ERROR

4-Warning

Error adding Mobility member to heartbeat list (IP: [chars])

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-4-HB_MEMBER_ADD_ERROR

4-Warning

Error adding Mobility member to heartbeat list (MAC: %02x:%02x:%02x:%02x:%02x:%02x, IP: [chars])

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-4-HB_MEMBER_DELETE_BY_IP_ERROR

4-Warning

Error deleting Mobility member from heartbeat list (IP: [chars])

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-4-HB_MEMBER_DELETE_ERROR

4-Warning

Error deleting Mobility member from heartbeat list (MAC: %02x:%02x:%02x:%02x:%02x:%02x, IP: [chars])

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-4-HEARTBEAT_LIST_MEMBER_UPDATE_ERROR

4-Warning

Error updating Mobility member IP in heartbeat list (MAC: %02x:%02x:%02x:%02x:%02x:%02x,, oldIP: [chars], newIP: [chars])

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_ACTION

MM_NODE_LOG-4-MEMBER_DOWN

4-Warning

[chars] path to mobility member [chars] is DOWN

A path to mobility member is DOWN

ewlc-mobility

If this message occurs, it implies that there is loss of network connectivity between the WLC and one of its mobility peers. It is recommended that the network and the status of the peers be debugged for connectivity issues.

MM_NODE_LOG-4-PMTU_FAILED

4-Warning

Capwap path MTU discovery error: [chars]

Mobility path MTU discovery failure

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-4-PMTU_SET_FAILED

4-Warning

Failed to set path MTU to fast path for peer IP: [chars]

LOG_EXPL_SYSERR

ewlc-mobility

LOG_STD_RECUR_ACTION

MM_NODE_LOG-6-HEARTBEAT_LIST_MEMBER_UPDATED

6-Information

Updating Mobility member IP in heartbeat list (MAC: %02x:%02x:%02x:%02x:%02x:%02x,, oldIP: [chars], newIP: [chars])

LOG_EXPL_SYSINFO

ewlc-mobility

LOG_STD_NO_ACTION

MM_NODE_LOG-6-MEMBER_ADDED

6-Information

Adding Mobility member (IP: [chars]: [chars])

LOG_EXPL_SYSINFO

ewlc-mobility

LOG_STD_NO_ACTION

MM_NODE_LOG-6-MEMBER_DELETED

6-Information

Deleting Mobility member (IP: [chars])

LOG_EXPL_SYSINFO

ewlc-mobility

LOG_STD_NO_ACTION

MM_NODE_LOG-6-MEMBER_UP

6-Information

[chars] path to mobility member [chars] is UP

A path to mobility member is UP

ewlc-mobility

LOG_STD_NO_ACTION

MM_NODE_LOG-6-MEMBER_UPDATED

6-Information

Updating Mobility member (IP: [chars]: [chars])

LOG_EXPL_SYSINFO

ewlc-mobility

LOG_STD_NO_ACTION

MM_NODE_LOG-6-MM_EXPORT_ANCHOR_FULL_RESET

6-Information

Export Anchor back off condition cleared (AnchorIP: [chars])

LOG_EXPL_SYSINFO

ewlc-guest

LOG_STD_NO_ACTION

MM_NODE_LOG-6-PING_RECEIVER_ENTRY_DELETED

6-Information

Deleted ping receiver entry ([chars]) from heartbeat list for WLAN ([dec])

LOG_EXPL_SYSINFO

ewlc-mobility

LOG_STD_NO_ACTION

MM_NODE_LOG-6-SOCK_SET_ADDRESS_OPTION

6-Information

Setting [chars] multicast group [chars] on the mobility sockets.

Multicast group membership was set on the socket.

ewlc-mobility

LOG_STD_NO_ACTION

MOBILITYD_LOG-2-INIT_FAILED

2-Critical

Error while initializing mobility daemon. [chars]

Error while initializing mobility daemon

ewlc-mobility

If this error is seen, it is recommended that the controller's mobility configuration be redone as it may have been lost. If you still require assistance, open a case with the Technical Assistance Center via the Internet or contact your Cisco technical support

NDBMAN-3-CONFIG_COMMIT_FAIL

3-Error

Commit failed for feature '[chars]' from [chars]:[dec] via [chars] user [chars] session [dec], transaction-id [dec]i error [chars]

A failed attempt to change running configuration was made via one of the model-based interfaces NETCONF/RESTCONF/GNMI. Configuration was successfully validated by the feature during the validation phase of the transaction but failed during the commit phase

ddmi-infra

Check the device cnfiguration. Collect device logs. Reinitialize the model-based component

NDBMAN-4-CONFIG_REJECT_W

4-Warning

Config rejected by feature '[chars]' from [chars]:[dec] via [chars] user [chars] session [dec], transaction-id [dec] error [chars]

A failed attempt to change running configuration was made via one of the model-based interfaces NETCONF/RESTCONF/GNMI. Either the feature validation logic rejected the config change as invalid or an error occured during an attempt to validate the config modification

ddmi-infra

Informational only. No action required.

NDBMAN-5-ACTIVE

5-Notice

All data providers active.

All data providers active.

ddmi-infra

Informational only. No action required.

NDBMAN-5-CONFIG_I

5-Notice

Configured feature '[chars]' from [chars]:[dec] via [chars] user [chars] session [dec], transaction-id [dec]

A change to the running configuration was performed via one of the model-based interfaces NETCONF/RESTCONF/GNMI.

ddmi-infra

Informational only. No action required.

NDBMAN-5-MODEL_RPC_I

5-Notice

RPC '[chars]:[chars]' invoked from [chars]:[dec] via [chars] user [chars] session [dec]

A model remote procedure call was performed via one of the model-based interfaces NETCONF/RESTCONF/GNMI.

ddmi-infra

Informational only. No action required.

NDBMAN-5-RESET

5-Notice

A data provider has stopped.

At least one data provider has stopped.

ddmi-infra

Informational only. No action required.

NDBUTIL-4-OUT_OF_RANGE_FOR_DECIMAL64_AND_FD

4-Warning

Double (%1$s) with value (%2$lf) is out-of-range (-%3$ld to %3$ld, exclusive) for a Decimal64 with fraction-digits = %4$d.

The value of the EI double cannot be reliably converted to Yang Decimal64 with the specified fraction-digits with the proper precision, so the EI to Yang conversion is intentionally failing. The EI value should not be this big, so there's an error with the module setting the attribute's value.

ddmi-infra

Report an error to the Cisco engineering team responsible for the module that's setting the attribute.

NEIGHBORHOOD_LOG-5-AP_NEIGHBORHOOD_APPLY

5-Notice

AP neighborhood based algorithm applied. [dec] number of APs have been load-balanced across WNCd instances.

RF based AP neighborhood algorithm is applied

ewlc-ap

If this message occurs, it implies that number of APs required load-balanced as per the load-balancing output

NEIGHBORHOOD_LOG-5-AP_NEIGHBORHOOD_DONE

5-Notice

AP clustering and WNCD assignment algorithm completed. [dec] number of AP neighborhoods formed and ready to load-balance across WNCD instances.

RF based AP clustering formation is done and sub-neighborhoods have been allocated the WNCD instances

ewlc-ap

If this message occurs, it implies that all AP can be loadbalanced by using exec apply CLI or reload of the controller

NEIGHBORHOOD_LOG-5-AP_NEIGHBORHOOD_START

5-Notice

Starting AP clustering and WNCD assignment algorithm. Total number of APs collected for calculation: [dec].

Notification to start the neighborhood calcultion

ewlc-ap

If this message occurs, Neighborhood algorithm is in progress.

NEIGHBORHOOD_LOG-5-AP_NEIGHBORHOOD_TIMER_EVENT

5-Notice

RRM based AP neighborhood algorithm cannot be started within 1 hour of system boot on calendar profile timer expiry event.

Calander profile start timer expiry event is ignored

ewlc-ap

If this message occurs, it implies that AP neighborhood algorithm is not started on timer expiry event.

NEIGHBORHOOD_LOG-5-AP_NEIGHBORHOOD_UNSUPPORTED

5-Notice

RF based AP neighborhood load-balancing is not applicable to this platform. Please unconfigure calendar profile from ap neighborhood global configuration.

Calander profile timer event callback handling error

ewlc-ap

If this message occurs, it implies that a calander profile is attached to ap neighborhood config on an unsupported platform

NIF_MGR-6-DAD

6-Information

Dual Active detected: [chars]\n

Dual Active detected print on console.

iosxe-fwdmgr

No action. Action is only after recovery mode

NIF_MGR-6-DAD_RECOVERY_MODE

6-Information

Dual Active detected: Switch going into recovery mode [chars].\n

Dual Active detected print on console.

iosxe-fwdmgr

This switch need to be reloaded once user finishes debugging

NIF_MGR-6-DAD_RECOVERY_RELOAD_ALERT

6-Information

Switch is in recovery mode, needs Reload now. [chars].\n

Switch is in recovery mode, needs Reload now

iosxe-fwdmgr

This switch need to be reloaded since some correction is noticed

NIF_MGR-6-DOMAIN_NUMBER_MISMATCH

6-Information

Stackwise virtual domain number mismatch on stackwise virtual link [dec]\n

A port associated with a stackwise virtual link is connected to a peer with a different domain number than the local switch

iosxe-fwdmgr

For the switch to form a stack please configure same domain numbers on both the switches

NIF_MGR-6-PORT_CONNECTION_STATUS_CHANGE

6-Information

PORT:[chars] changed state from [chars] to [chars].\n

FSS Stack Port status change message.

iosxe-fwdmgr

No action is required

NIF_MGR-6-PORT_CONN_DISCONNECTED

6-Information

[chars] on front side stack link [dec] connection has DISCONNECTED: [chars]\n

A port associated with a front side stack link has disconnected connection.

iosxe-fwdmgr

No action is required

NIF_MGR-6-PORT_CONN_ERR

6-Information

[chars] on front side stack link [dec] connection is in ERR-DISABLE: [chars]\n

A port associated with a front side stack link has reached err-disable state.

iosxe-fwdmgr

No action is required

NIF_MGR-6-PORT_CONN_PENDING

6-Information

[chars] on front side stack link [dec] connection is PENDING.\n

A port associated with a front side stack link has a pending connection.

iosxe-fwdmgr

No action is required

NIF_MGR-6-PORT_CONN_READY

6-Information

[chars] on front side stack link [dec] connection is READY.\n

A port associated with a front side stack link has a ready connection.

iosxe-fwdmgr

No action is required

NIF_MGR-6-PORT_CONN_TIMEOUT

6-Information

[chars] on front side stack link [dec] connection has TIMEOUT: [chars]\n

A port associated with a front side stack link has disconnected connection.

iosxe-fwdmgr

No action is required

NIF_MGR-6-PORT_LINK_DOWN

6-Information

[chars] on front side stack link [dec] is DOWN.\n

A port associated with a front side stack link has come up.

iosxe-fwdmgr

No action is required

NIF_MGR-6-PORT_LINK_UP

6-Information

[chars] on front side stack link [dec] is UP.\n

A port associated with a front side stack link has come up.

iosxe-fwdmgr

No action is required

NIF_MGR-6-STACK_LINK_DOWN

6-Information

Front side stack link [dec] is DOWN.\n

A port associated with a front side stack link has come up.

iosxe-fwdmgr

No action is required

NIF_MGR-6-STACK_LINK_UP

6-Information

Front side stack link [dec] is UP.\n

A port associated with a front side stack link has come up.

iosxe-fwdmgr

No action is required

NIM_XXD-3-DISK_ERROR

3-Error

Error detected on disk [dec] in module [chars] in subslot [dec]/[dec]. [chars].

Disk error detected in the SPA (NIM-SSD/NIM-HDD). Refer to comment for details.

iosxe-chassismgr

Back-up any data and replace the disk.

NIM_XXD-3-DISK_REMOVAL

3-Error

One or more disks in SPA ([chars]) in subslot [dec]/[dec] can not be detected. Please power down this SPA and insert disk(s).

Disks have been removed from SPA

iosxe-chassismgr

Power down the SPA, insert disks and power up the SPA.

NIM_XXD-5-DISK_MONITOR

5-Notice

Disk [dec] in module [chars] in subslot [dec]/[dec] is detected but monitoring is not available.

Monitoring of disk in SPA (NIM-SSD/NIM-HDD) is unavailable.

iosxe-chassismgr

Add a database file with monitoring information for this disk model and manufacturer.

NMSP_SYSLOG-3-NMSP_DB_LOCK_NOT_ACQUIRED

3-Error

NMSP client application is expected to acquire lock for NMSP local database before calling NMSP API: [chars]

Locking sequence for the DB's is defined in this application. The locking order of DB's needs to be followed as per the application set order, where local DB come first. NMSP client application must acquire local DB lock before calling NMSP API

ewlc-nmsp

LOG_STD_ACTION

NMSP_SYSLOG-3-NMSP_HTTPS_ERROR_CONFIG

3-Error

nmspd cloud service config error: [chars]

Configuration error prevented successful connection to CMX cloud service.

ewlc-nmsp

Check configuration of cmx cloud service, e.g. server URL and token.

NMSP_SYSLOG-3-NMSP_HTTPS_ERROR_CRYPTO

3-Error

nmspd HTTPS error: [chars]

Peer verification of CMX cloud service failed.

ewlc-nmsp

Check that server certificate can be verified by root CA certificates in trustpool of crypto PKI.

NMSP_SYSLOG-3-NMSP_SSL_ERROR_CERT

3-Error

nmspd TLS certificate error: [chars]

Error validating TLS certificate for incoming CMX connection

ewlc-nmsp

Check that certificates and SHA2 key are properly setup on eWLC. Contact TAC if issue persists.

NMSP_SYSLOG-3-NMSP_SSL_ERROR_DISCONNECT

3-Error

nmspd TLS disconnection: [chars]

Remote CMX connection over TLS protocol had been dropped.

ewlc-nmsp

Check connectivity with CMX, CMX service status and AAA configuration.

NMSP_SYSLOG-3-NMSP_SSL_ERROR_INTERNAL

3-Error

nmspd internal error occured when handling TLS connection: [chars]

Internal eWLC error prevented successful establishment of CMX connection over TLS protocol

ewlc-nmsp

Check availability of the system resources of the eWLC controller: memory, open files, sockets. Contact TAC if issue persists

NMSP_SYSLOG-5-NMSP_HTTPS_INTERFACE_NOTICE

5-Notice

nmspd HTTPS info: [chars]

Wireless management interface notification.

ewlc-nmsp

No action required.

NMSP_SYSLOG-5-NMSP_HTTPS_NOTICE

5-Notice

nmspd HTTPS info: [chars]

This is an informational message.

ewlc-nmsp

No action required.

NMSP_SYSLOG-5-NMSP_SSL_NOTICE

5-Notice

nmspd TLS notice: [chars]

This is an informational message.

ewlc-nmsp

No action required.

NODE_HDLR-1-DUAL_ACTIVE_CFG_MSG

1-Alert

Dual Active Detection [chars]\n

Switch detected availability or unavailability of Dual Active Detection ports.

iosxe-fwdmgr

No action is required

NODE_HDLR-1-EPA_MISMATCH

1-Alert

[chars]. The mis-match may caused by hardware failure or different EPA types.\n

The Standby EPA mismatch with Active EPA.

iosxe-fwdmgr

Need to make them match

NODE_HDLR-1-FATAL_ERR

1-Alert

Stack manager encountered an unrecoverable error. [chars]\n

The stack manager process has encountered an unrecoverable error and the switch is being reloaded.

iosxe-fwdmgr

Please ensure valid switch numbers are being used. If you still believe there is an error in the system, please send the system report to a TAC representative

NODE_HDLR-1-LIC_MISMATCH

1-Alert

License level is [chars] and needs to be upgraded to [chars] for Stackwise Virtual to function.\n

Current Licnese level on active switch does not support Stackwise Virtual.

iosxe-fwdmgr

Need to be upgraded to supported license level

NODE_HDLR-1-RELOAD

1-Alert

Reloading due to reason [chars]\n

The specified switch has received a reload request and is being reloaded.

iosxe-fwdmgr

No action is required

NODE_HDLR-1-RELOAD_REQUEST

1-Alert

Received reload request for [chars], reason [chars]\n

The specified switches are being reloaded.

iosxe-fwdmgr

No action is required

NODE_HDLR-1-STACK_MERGE_IGNORE

1-Alert

Stack Merge Ignored [chars]\n

Switch detected multiple Active switches. But stack-merge is being ignored.

iosxe-fwdmgr

No action is required

NODE_HDLR-4-SWITCH_ADDED

4-Warning

[chars] [dec] has been added to the stack.\n

The specified switch has been added to the stack.

iosxe-fwdmgr

No action is required

NODE_HDLR-4-SWITCH_REMOVED

4-Warning

[chars] [dec] has been removed from the stack.\n

The specified switch has been removed from the stack.

iosxe-fwdmgr

No action is required

NODE_HDLR-5-CHASSIS_ROLE_UPDATE_FAIL

5-Notice

Failed to Set [chars] Chassis [dec] chassis_role [chars]

This is used to indicate that update to new role failed

iosxe-fwdmgr

This is a rare failure condition. Please reach out to TAC

NODE_HDLR-5-FAST_RELOAD_DONE

5-Notice

Fast reload operation completed successfully on entire stack

This is used to indicate that the fast reload on stack is complete.

accsw-p-fsu

No action needed. This is not an error.

NODE_HDLR-6-ACTIVE_ELECTED

6-Information

[chars] [dec] has been elected ACTIVE.\n

The specified switch has been elected active.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-ACTIVE_READY

6-Information

Active [chars] [dec] is ready.\n

The active switch is ready.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-CHASSIS_ADDED

6-Information

[chars] [dec] has been added to the stack.\n

The specified chassis has been added to the stack.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-CHASSIS_READY

6-Information

[chars] [dec] is ready.\n

The specified chassis is ready.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-CHASSIS_REMOVED

6-Information

[chars] [dec] has been removed from the stack.\n

The specified chassis has been removed from the stack.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-CHASSIS_REMOVED_KA

6-Information

[chars] [dec] has been removed from the stack due to keepalive failure. \n

Chassis has been removed due to the keepalive failure.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-DISC_DONE

6-Information

[chars] [dec] has finished stack discovery.\n

The specified switch has completed stack discovery and is moving to the election phase.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-DISC_START

6-Information

[chars] [dec] is starting stack discovery.\n

The specified switch is starting stack discovery.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-KA_MISSED

6-Information

Keepalive missed for [dec] times for [chars] [dec] \n

Chassis has been removed due to the keepalive failure.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-STACK_LINK_CHANGE

6-Information

Stack port [dec] on [chars] [dec] is [chars]\n

The specified stack port has changed status.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-STANDBY_ELECTED

6-Information

[chars] [dec] has been elected STANDBY.\n

The specified switch has been elected standby.

iosxe-fwdmgr

No action is required

NODE_HDLR-6-SWITCH_READY

6-Information

[chars] [dec] is ready.\n

The specified switch is ready.

iosxe-fwdmgr

No action is required

NPI_L3TUNNEL_ERRMSG-3-MAX_TUNNEL

3-Error

The maximum number of Tunnel has been reached\n

Hardware resource allocation has failed and the entry will not be programmed.

INVALID

New Tunnels will not be working as expected.

ODM_SERVER_ERRMSG-3-ODM_TABLE_REGISTER_DB_NOT_CONFIG

3-Error

Client ([chars]/[dec]) table [[chars]/[chars]] registration DB [[chars]] is not found in server configuration

ODM client is registering its monitored TDL database tables to ODM server daemon. But ODM server daemon doesn't have requested (consolidated) database information.

iosxe-p-db

LOG_STD_ACTION

ODM_SERVER_ERRMSG-3-ODM_TABLE_REGISTER_TABLE_NOT_CONFIG

3-Error

Client ([chars]/[dec]) table [[chars]/[chars]] registration table is not found in server DB [[chars]] configuration

ODM client is registering its monitored TDL database tables to ODM server daemon. But ODM server daemon doesn't have requested table information in consolidated database.

iosxe-p-db

LOG_STD_ACTION

ODM_SERVER_ERRMSG-4-ODM_TABLE_REGISTER_CONFIG_MISMATCH

4-Warning

Client ([chars]/[dec]) table [[chars]/[chars]] registration table configuration (0x%x) mis-matched with server configuration (0x%x)

ODM client is registring its monitored TDL database tables to ODM server daemon. But ODM table configuration is not matched between client and server.

iosxe-p-db

LOG_STD_ACTION

OMPD-3-PEER_STATE_INIT

3-Error

[chars] peer [chars] state changed to Init

This syslog is generated when OMP peer state changes to INIT

vip-omp

No action is required

OMPD-3-STATE_DOWN

3-Error

Operational state changed to [chars]

This syslog is generated when Cisco SD-WAN Overlay Management Protocol (OMP) goes DOWN

vip-omp

No action is required

OMPD-5-PEER_STATE_UP

5-Notice

[chars] peer [chars] state changed to Up

This syslog is generated when OMP peer state changes to UP

vip-omp

No action is required

OMPD-5-STATE_UP

5-Notice

Operational state changed to [chars]

This syslog is generated when Cisco SD-WAN Overlay Management Protocol (OMP) comes UP

vip-omp

No action is required

OMPD-6-NUMBER_OF_VSMARTS

6-Information

Number of vSmarts connected : [dec]

This info log is generated whenever SD-WAN edge device either establishes (or) looses connection with SD-WAN Controller nodes

vip-omp

No action is required

OMPD-6-PEER_STATE_HANDSHAKE

6-Information

[chars] peer [chars] state changed to Handshake

This syslog is generated when OMP peer state changes to HANDSHAKE

vip-omp

No action is required

OOM-0-NO_MEMORY_RESET

0-Emergency

The system is completely out of available memory. The board will be reset.

The system has exhausted all available memory and the hardware component will be reset.

iosxe-binos-utils

Review other messages related to low memory states and see if those messages contain any information about an issue that can be addressed. If this problem persists, copy all the output from the console as well as the output of show tech-support, and provide the gathered information to your Cisco technical support representative.

OOM-3-NO_MEMORY_AVAIL

3-Error

The system is very low on available memory. Operations will begin to fail.

The system has exhausted all available memory. It is not possible to continue stable operation.

iosxe-binos-utils

The system has exhausted all available memory and stable operation is no longer possible.

P to T

Facility-Severity-Mnemonic

Severity-Meaning

Message

Message-Explanation

Component

Recommended-Action

PAE_CORE_TEST-6-REPORT_ID

6-Information

Created report id: [chars]

Result of the test report request

iosxe-ui

LOG_STD_NO_ACTION

PAM_UPDB-3-NOENVIRONMENT_SET

3-Error

Error setting user in application environment: [chars]

The user has succesfully authenticated, but the user information could not be saved to the application environment. The user session will not proceed.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

PAM_UPDB-3-NOPROMPT_READ

3-Error

Error reading [chars] prompt: [chars]

The authentication module was unable to read the specified prompt file. The default prompt will be used.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

PCGW_HA_LIB_MESSAGE-3-BULK_SYNC_STATE_ERR

3-Error

Error: Bulk sync status : [chars]

Bulk sync status Error message. TERMINATED - Bulk-sync terminated

pcgw-ha

LOG_STD_NO_ACTION

PCGW_HA_LIB_MESSAGE-3-PCGW_CONFIG_SYNC_FAIL

3-Error

Error: pcgw config sync not complete. Reloading the PCGW!

Switchover happens before pcgw config sync is complete!

pcgw-ha

LOG_STD_ACTION

PCGW_HA_LIB_MESSAGE-6-BULK_SYNC_STATE_INFO

6-Information

INFO: Bulk sync status : [chars]

Bulk sync status INFO message. COLD - Bulk-sync ongoing. CONFIG_DONE - critical DB sync complete. WARM - Most of the DB's synced. HOT - Bulk-sync completed

pcgw-ha

LOG_STD_NO_ACTION

PEER_SELECTION-5-EWC_PEER_SELECTION_ADD_EV

5-Notice

ADD event: [chars]

Reports an important HA peer (a.k.a. standby) selection ADD event

iosxe-binos-utils

LOG_STD_NO_ACTION

PEER_SELECTION-5-EWC_PEER_SELECTION_PREFER_EV

5-Notice

Preferred master event: [chars]

Reports an important HA peer (a.k.a. standby) selection preferred master event

iosxe-binos-utils

LOG_STD_NO_ACTION

PEER_SELECTION-5-EWC_PEER_SELECTION_REMOVE_EV

5-Notice

REMOVE event: [chars]

Reports an important HA peer (a.k.a. standby) selection REMOVE event

iosxe-binos-utils

LOG_STD_NO_ACTION

PEER_SELECTION-5-EWC_PEER_SELECTION_SELECT_EV

5-Notice

SELECT event: [chars]

Reports an important HA peer (a.k.a. standby) selection SELECT event

iosxe-binos-utils

LOG_STD_NO_ACTION

PLATFORM-2-S1_ASIC_FABRIC_BW_ABOVE_THRESHOLD

2-Critical

S1 ASIC EVENT: The number of fabric ports in the S1 ASIC [dec] are above the system threshold.\n

Silicon one ASIC fabric port threshold event

INVALID

Check the fabric info for the S1 ASIC

PLATFORM-2-S1_ASIC_FABRIC_BW_BELOW_THRESHOLD

2-Critical

S1 ASIC EVENT: The number of fabric ports in the S1 ASIC [dec] are below the system threshold.\n

Silicon one ASIC fabric port threshold event

INVALID

Check the fabric info for the S1 ASIC

PLATFORM-2-S1_ASIC_THROTTLING_DISABLE

2-Critical

S1 ASIC EVENT: S1 ASIC [dec] temperature is back to normal. Traffic throttling is disabled now.\n

Silicon one ASIC overheating event

INVALID

Copy the message exactly as it appears on the console or in the system log

PLATFORM-2-S1_ASIC_THROTTLING_ENABLE

2-Critical

S1 ASIC EVENT: A high temperature condition is detected in S1 ASIC [dec]. The system will automatically enable traffic throttling in an attempt to restore temperatures and prevent permanent damage to the ASIC. Traffic drops are expected in this scenario and normal traffic behaviour will resume after the ambient ASIC temperatures are restored.\n

Silicon one ASIC overheating event

INVALID

Check the ambient temperature of the room and check for blockages in airflow

PLATFORM-3-ELEMENT_CRITICAL

3-Error

[chars]: [chars] value [chars] [chars] critical level [chars]

The Shell Manager monitors the health of each board and emits an error message when a value has passed a critical level.

iosxe-shellmgr

Reduce static and dynamic loads on the system by reducing the number of elements in the configuration or by limiting the capacity for dynamic services.

PLATFORM-3-ELEMENT_TMPFS_CRITICAL

3-Error

[chars]: TMPFS value [dec]%% above critical level [dec]%%

The Shell Manager monitors the tmpfs usage of each board and emits an error message when a value has passed warning level. The critical level is computed based on total DRAM memory. Currently the critical level is 50% of total DRAM memory

iosxe-shellmgr

Emit syslog message with current tmpfs usage, warning level along with location of the board in which the error is happening

PLATFORM-3-ELEMENT_TMPFS_WARNING

3-Error

[chars]: TMPFS value [dec]%% above warning level [dec]%%

The Shell Manager monitors the tmpfs usage of each board and emits an error message when a value has passed warning level.The warning level is computed based on total DRAM memory. Currently the warning level is 40% of total DRAM memory

iosxe-shellmgr

Emit syslog message with current tmpfs usage, warning level along with location of the board in which the error is happening

PLATFORM-4-ELEMENT_WARNING

4-Warning

[chars]: [chars] value [chars] [chars] warning level [chars]. [chars]

The Shell Manager monitors the health of each board and emits a warning message when a value has passed a critical level.

iosxe-shellmgr

Reduce static and dynamic loads on the system by reducing the number of elements in the configuration or by limiting the capacity for dynamic services.

PLATFORM-5-RESETCARD

5-Notice

[chars] reset to acquire provisioned software

The linecard specified was not running the currently provisioned software, which it will acquire on restart.

iosxe-binos-utils

No user action is necessary. This message indicates the system is functioning normally and is provided for informational purposes only.

PLATFORM_MGR-1-PLATMGR_INIT_FAIL

1-Alert

Platform Manager: [chars]\n

Platform Manager Initialization has failed.

polaris-platform_mgr

Find out more about the error by using the show tech-support privileged EXEC command and by copying the error message exactly as it appears on the console or system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems.

PMAN-0-PROCESS_NOTIFICATION

0-Emergency

The process lifecycle notification component failed because [chars]

The process lifecycle notification component failed, preventing proper detection of a process start and stop. This problem is likely the result of a software defect in the software sub-package.

iosxe-chassismgr

Note the time of the message and investigate the kernel error message logs to learn more about the problem and see if it is correctable. If the problem cannot be corrected or the logs are not helpful, copy the error message exactly as it appears on the console along with the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PMAN-0-PROCFAILCRIT

0-Emergency

A critical process [chars] has failed (rc [dec])

A process important to the functioning of the router has failed.

iosxe-chassismgr

Note the time of the message and investigate the error message logs to learn more about the problem. If the problem persists, copy the error message and the output of show platform software tech-support into a plaintext file and contact Cisco technical support with the gathered information.

PMAN-3-PROCFAIL

3-Error

The process [chars] has failed (rc [dec])

The process has failed as the result of an error.

iosxe-chassismgr

This message will appear with other messages related to the process. Check the other messages to determine the reason for the failures and see if corrective action can be taken. If the problem persists, copy the error messages and the output of show platform software tech-support into a plaintext file and contact Cisco technical support.

PMAN-3-PROCFAILOPT

3-Error

An optional process [chars] has failed (rc [dec])

A process that does not affect the forwarding of traffic has failed.

iosxe-chassismgr

Note the time of the message and investigate the kernel error message logs to learn more about the problem. Although traffic will still be forwarded after receiving this message, certain functions on the router may be disabled as a result of this message and the error should be investigated. If the logs are not helpful or indicate a problem you cannot correct, copy the error message as it appears on the console and the output of show tech-support and provide the information to a Cisco technical support representative.

PMAN-3-PROCFAIL_IGNORE

3-Error

[chars] process exits and failures are being ignored due to debug settings. Normal router functionality will be affected. Critical router functions like RP switchover, router reload, FRU resets, etc. may not function properly.

A process exit or failure is being ignored due to the user-configured debug settings.

iosxe-chassismgr

If this behavior is desired and the debug settings are set according to the user's preference, no action is needed. If the appearance of this message is viewed as a problem, change the debug settings. The router is not expected to behave normally with this debug setting. Functionality like SSO switchover, router reloads, FRU resets, etc. will be affected. This setting should only be used in a debug scenario. It is not normal to run the router with this setting

PMAN-3-PROCHOLDDOWN

3-Error

The process [chars] has been helddown (rc [dec])

The process was restarted too many times with repeated failures and has been placed in the holddown state.

iosxe-chassismgr

This message will appear with other messages related to the process. Check the other messages to determine the reason for the failures and see if corrective action can be taken. If the problem persists, copy the error messages and the output of show platform software tech-support into a plaintext file and contact Cisco technical support.

PMAN-3-PROC_BAD_COMMAND

3-Error

Non-existent executable or bad library used for process [chars]

The executable file used for the process is missing or a dependent library is bad

iosxe-chassismgr

Make sure that the named executable is present and dependent libraries are good

PMAN-3-PROC_BAD_EXECUTABLE

3-Error

Bad executable or permission problem with process [chars]

The executable file used for the process is bad or has permission problem

iosxe-chassismgr

Make sure that the named executable is replaced with correct executable

PMAN-3-PROC_EMPTY_EXEC_FILE

3-Error

Empty executable used for process [chars]

The executable file used for the process is empty

iosxe-chassismgr

Make sure that the named executable is of non-zero size

PMAN-3-PROC_RESTART_CNT_EXCEEDED

3-Error

The process [chars] restart count ([dec]) has exceeded the configured limit ([dec])

The process was restarted many times and has exceeded the configured limit.

iosxe-chassismgr

This message will appear with other messages related to the process. Check the other messages to determine the reason for the failures and see if corrective action can be taken. If the problem persists, copy the error messages and the output of show platform software tech-support into a plaintext file and contact Cisco technical support.

PMAN-3-RELOAD_FRU_IGNORED

3-Error

All [chars]/[dec] reloads are being ignored. This is being done for debugging purposes and will be changed at a later time to allow the reload. Critical router functions like RP switchover, router reload, FRU resets, etc. may not function properly.

A supervisor failure is being ignored due to debugging purposes.

iosxe-chassismgr

This will be removet at a later point in time

PMAN-3-RELOAD_RP

3-Error

Reloading: [chars]

The RP is being reloaded

iosxe-chassismgr

Make sure this is not due to an error condition. If it is due to an error condition, collect information requested by the other log messages

PMAN-3-RELOAD_RP_SB_NOT_READY

3-Error

Reloading: [chars]

The RP is being reloaded since there is no ready standby instance

iosxe-chassismgr

Make sure this is not due to an error condition

PMAN-3-RELOAD_SYSTEM

3-Error

Reloading: [chars]

The system is being reloaded

iosxe-chassismgr

Make sure this is not due to an error condition. If it is due to an error condition, collect information requested by the other log messages

PMAN-3-RPSWITCH

3-Error

RP switch initiated. Critical process [chars] has failed (rc [dec])

A RP switchover has been initiated due to a critical fault

iosxe-chassismgr

Make sure this is not due to an error condition. If it is due to an error condition, collect debug information like all console output and log files

PMAN-5-EXITACTION

5-Notice

Process manager is exiting: [chars]

The process manager is exiting

iosxe-chassismgr

Make sure this is not due to an error condition. If it is due to an error condition, collect information requested by the other log messages

PMAN-6-PROCSHUT

6-Information

The process [chars] has shutdown

The process has gracefully shutdown.

iosxe-chassismgr

No user action is necessary. This message is provided for informational purposes only.

PMAN-6-PROCSTART

6-Information

The process [chars] has started

The process has launched and is operating properly.

iosxe-chassismgr

No user action is necessary. This message is provided for informational purposes only.

PMAN-6-PROCSTATELESS

6-Information

The process [chars] is restarting stateless

The process has requested a stateless restart.

iosxe-chassismgr

No user action is necessary. This message is provided for informational purposes only.

PMAN-6-PROC_PATCH

6-Information

Process [chars] restarted to apply/remove a patch

Process will be relaunched to apply/remove a patch

iosxe-chassismgr

No user action is necessary. This message is provided for informational purposes only.

POLICY-3-DATA_POLICY_COMMIT_FAILURE

3-Error

Data policy commit failure error, reason: [chars] ([chars])

This error syslog is generated when OMP daemon is not able to commit data policies config, received from SD-WAN Controller, into config database. This can happen when there multiple commits (writes) happening in parallel. SD-WAN edge device will not be able to apply centralized data policies to traffic

vip-omp

No action is required, the system should recover after sometime when OMP daemon would retry committing data policy config into CDB

POLICY-3-TAG_INSTANCES_COMMIT_FAILURE

3-Error

Tag instances commit failure error, reason: [chars] ([chars])

This error syslog is generated when OMP daemon is not able to commit tag instances config, received from SD-WAN Controller, into config database. This can happen when there multiple commits (writes) happening in parallel SD-WAN edge device will not be able to apply centralized data policies to traffic

vip-omp

No action is required, the system should recover after sometime when OMP daemon would retry committing tag instance config into CDB

POLICY-5-EMPTY_POLICY_FROM_PEER

5-Notice

Using empty policy from peer [chars]

This syslog is generated when Cisco SD-WAN Controller does not push (or) removes centralized data policy from cEdge device

vip-omp

No action is required

POLICY-5-NO_POLICY

5-Notice

Not using any policy

This syslog is generated when there are no OMP connections to Cisco SD-WAN Controller and Graceful Restart timer has also expired. Existing centralized data policy is removed

vip-omp

No action is required

POLICY-5-POLICY_FROM_PEER

5-Notice

Using policy from peer [chars]

This syslog is generated whenever data-policy config received from Cisco SD-WAN Controller is programmed into data path

vip-omp

No action is required

PRELIB_DL-3-UNREGISTERED_DLOPEN

3-Error

Unregistered request to dlopen library [chars]

The program is attempting to dynamically open a library that has not been explicitly listed on its list of dynamically opened libraries. This represents a potential security threat as well as creates potential run-time instabilities

iosxe-binos-utils

File a DDTS against the listed program to register the library in question. If this was an unexpected call to dlopen then the source of the call should be root-caused and closed

PSD_MOD-3-DMI_DIR_CREATE_FAIL

3-Error

PSD/DMI: Failed to create directory: [chars] ([chars])

An error has occurred when attempting to create a directory.

ddmi-infra

Log a message

PSD_MOD-3-DMI_DIR_DELETE_FAIL

3-Error

PSD/DMI: Failed to delete directory: [chars] ([chars])

An error has occurred when attempting to delete a directory.

ddmi-infra

Log a message

PSD_MOD-3-DMI_FILE_CREATE_FAIL

3-Error

PSD/DMI: Failed to create file: [chars] ([chars])

An error has occurred when attempting to create a file.

ddmi-infra

Log a message

PSD_MOD-3-DMI_FILE_DELETE_FAIL

3-Error

PSD/DMI: Failed to delete file: [chars] ([chars])

An error has occurred when attempting to delete a file.

ddmi-infra

Log a message

PSD_MOD-3-SD_ROUTING_DMI_REQUIRED

3-Error

PSD/SD-ROUTING: Please configure netconf-yang to activate the sd-routing feature

SD-Routing depends upon DMI

cntrl-mng-rtg

Not applicable

PSD_MOD-5-DMI_NOTIFY_NETCONF_START

5-Notice

PSD/DMI: netconf-yang server has been notified to start

A specific informational message from psd_mod

ddmi-infra

Not applicable

PSD_MOD-5-DMI_NOTIFY_NETCONF_STOP

5-Notice

PSD/DMI: netconf-yang server has been notified to stop

A specific informational message from psd_mod

ddmi-infra

Not applicable

PSD_MOD-5-DMI_NOTIFY_RESTARTING

5-Notice

PSD/DMI: netconf-yang and/or restconf will now be restarted, and any sessions in progress will be terminated

A specific informational message from psd_mod

ddmi-infra

Not applicable

PSD_MOD-5-DMI_NOTIFY_RESTCONF_START

5-Notice

PSD/DMI: restconf server has been notified to start

A specific informational message from psd_mod

ddmi-infra

Not applicable

PSD_MOD-5-DMI_NOTIFY_RESTCONF_STOP

5-Notice

PSD/DMI: restconf server has been notified to stop

A specific informational message from psd_mod

ddmi-infra

Not applicable

PSD_MOD-5-DMI_NOTIFY_USER

5-Notice

PSD/DMI: [chars]

An informational message from psd_mod

ddmi-infra

Not applicable

PSD_MOD-5-PSID_NOTIFY_SYSTEM_INTEGRITY_START

5-Notice

SYSTEM INTEGRITY: pistis daemon has been notified to start

A specific informational message from psd_mod

polaris-infra

Not applicable

PSD_MOD-5-PSID_NOTIFY_SYSTEM_INTEGRITY_STOP

5-Notice

SYSTEM INTEGRITY: pistis daemon has been notified to stop

A specific informational message from psd_mod

polaris-infra

Not applicable

PSD_MOD-5-SD_ROUTING_NOTIFY_START

5-Notice

PSD/SD-ROUTING: SD-Routing server has been notified to start

A specific informational message from psd_mod

cntrl-mng-rtg

Not applicable

PSD_MOD-5-SD_ROUTING_NOTIFY_STOP

5-Notice

PSD/SD-ROUTING: SD-Routing server has been notified to stop

A specific informational message from psd_mod

cntrl-mng-rtg

Not applicable

PTHUTIL-3-EVENT_HANDLER

3-Error

Task [chars] has no [chars] event handler

The task specified has failed to install a handler for the specified event. This implies that the event has been dropped.

iosxe-binos-utils

LOG_STD_ACTION

PTHUTIL-3-SCHED_EMPTY

3-Error

Scheduler has no tasks available

The Pth scheduler has detected that there is no task available to run. This is an error condition for the process itself is a task.

iosxe-binos-utils

LOG_STD_ACTION

PTHUTIL-3-SCHED_FD_OVERFLOW

3-Error

Scheduler has more than [dec] FDs

The are too many FDs for the Pth scheduler. This is an error condition for the process itself.

iosxe-binos-utils

LOG_STD_ACTION

PTHUTIL-3-STACK_OVERFLOW

3-Error

Task [chars] stack overflow

A Pth task has overflowed its stack. This has been detected by the Pth scheduler and reported.

iosxe-binos-utils

LOG_STD_ACTION

PTHUTIL-3-TIMER_THRASHING

3-Error

Timer [chars] is thrashing on [chars]

The Pth scheduler has detected that an event has remained on the ready queue after being notified of requiring processing.

iosxe-binos-utils

LOG_STD_ACTION

PTHUTIL-3-TIMER_UPDATE

3-Error

Timer [chars] update of [chars] not updated [dec]

The attempt to update a watched timer has failed due to either the timer not existing or the inability to move the timer to its new position post update.

iosxe-binos-utils

LOG_STD_ACTION

PTPD-0-CHASFS_OBJECT_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] because [chars]

The hardware failed to create a chassis filesystem object.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-CHASFS_OBJECT_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] not present.

A chassis filesystem object expected to be present is not. This could be due to a software defect or filesystem failure.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-CHASFS_OBJECT_WATCH

0-Emergency

Failed to watch chassis filesystem object [chars] because [chars]

A chassis filesystem object was not watched because of the reason stated in the error message.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-CHASFS_PROPERTY_CREATE

0-Emergency

Failed to create chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly created.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-CHASFS_PROPERTY_GET

0-Emergency

Failed to read chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property was not properly read by the system.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-CHASFS_PROPERTY_NOT_PRESENT

0-Emergency

Expected chassis filesystem object [chars] property [chars] not present.

A chassis filesystem object property expected to be present is not. This could be due to a software defect or filesystem failure.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-CHASFS_PROPERTY_SET

0-Emergency

Failed to write chassis filesystem object [chars] property [chars] because [chars]

A chassis filesystem property failed to write.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-IPC_CONNECTION_INVALID

0-Emergency

An IPC connection has invalid state.

An IPC connection has an invalid state. This could be due to a software defect or system resource exhaustion.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-IPC_CONNECT_MASTER

0-Emergency

IPC connection to the active RSP failed because [chars]

IPC connection to the active RSP failed. This could be due to a software defect or system resource exhaustion.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-IPC_INITIALIZATION

0-Emergency

IPC initialization failed because [chars]

IPC initialization failed. This could be due to a software defect or system resource exhaustion.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-MESSAGE_REGISTER

0-Emergency

Failed to register with active RSP because [chars]

The active RSP failed to register.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-MESSAGE_RELAY

0-Emergency

Failed to relay a message because [chars]

Failed to relay a message. This could be due to a software defect or system resource exhaustion.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-MESSAGE_RESPONSE

0-Emergency

An invalid message response was received because [chars]

An invalid message response was received. This could be due to a software defect or system resource exhaustion.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-MQIPC_ADVANCE

0-Emergency

Failed to advance MQIPC queue because [chars]

The MQIPC initialization failed.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-MQIPC_INITIALIZATION

0-Emergency

MQIPC initialization failed because [chars]

MQIPC initialization failed. This could be due to a software defect or system resource exhaustion.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-PEER_TABLE

0-Emergency

A peer table initialization or maintenance function failed because [chars]

A peer table initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-0-RESOURSE

0-Emergency

Resource allocation failed in [chars] because [chars]

The system is unable to allocate the requested resource.

asr900-ptp

In most cases, this message is seen as a result of a temporary resource issue. Retry the request for the resource when the system is experiencing lower traffic volumes. If the message persists, reload the router using the reload command.

PTPD-3-CHASFS_OBJECT_DESTROY

3-Error

Failed to destroy chassis filesystem object [chars] because [chars]

A chassis filesystem object that should have been destroyed was not destroyed.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

PTPD-3-CHASFS_PROPERTY_DESTROY

3-Error

Failed to destroy chassis filesystem proprty [chars]/[chars] because [chars]

A chassis filesystem property that should have been destroyed was not destroyed.

asr900-ptp

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

QOS_ERROR_MESSAGE-3-QOS_CLIENT_POLICY_AP_INSTALL_FAIL

3-Error

ERROR: Failed to install policy: [chars] for Client: %02x%02x.%02x%02x.%02x%02x on AP: [chars] with status: [chars]

Client policy install on AP failed.

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_CLIENT_POLICY_AP_SEND_FAIL

3-Error

ERROR: For Client mac %02x%02x.%02x%02x.%02x%02x, failed to send policy [chars] to AP due to reason: [chars]

Error Binding Client Policy. Policy not sent to AP

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_CLIENT_POLICY_AP_UNINSTALL_FAIL

3-Error

ERROR: Failed to uninstall policy: [chars] for Client: %02x%02x.%02x%02x.%02x%02x on AP: [chars] with status: [chars]

Client policy unbind operation on AP failed.

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_CREATE_POLICY_DB_FAIL

3-Error

ERROR: Unable to allocate resources for QoS Policy Content DB

Internal Error. Unable to allocate resources for QoS Policy Content DB

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_DOT11_CLIENT_RECORD_NOT_FOUND

3-Error

ERROR: Failed to get dot11 client record for Client: %02x%02x.%02x%02x.%02x%02x

QoS get function for dot11 client record failed.

ewlc-client

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_INVALID_POLICY

3-Error

ERROR: Policy [chars] is invalid in [chars] direction for vapid:[dec]

QoS policy validation failed. Policy will not be installed

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_MEM_ALLOC_FAIL

3-Error

Error: Failed to allocate memory [chars]

An internal error occurred due to which memory allocation failed

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_MODIFY_POLICY_DB_FAIL

3-Error

ERROR: Unable to modify QoS Policy due to Reason:[chars]

Internal Error. Unable to modify QoS Policy Content in DB

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_MSG_BLKLIST_CLIENT

3-Error

Blacklisting client %02x%02x.%02x%02x.%02x%02x. Error installing client QOS policy: [chars] in [chars] direction.

Failure occured while installing QoS client policy. Client will be deleted.

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_POLICY_EXCEED_MAX

3-Error

[dec] policy maps sent to AP [chars], exceeds the recommended [dec]

Number of policies exceeds limit warning.

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_POLICY_MISSING

3-Error

ERROR: Policy [chars] in [chars] direction for vapid:[dec] has no content

QoS policy validation failed. Policy will not be installed

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_SSID_INVALID_POLICY

3-Error

ERROR: Policy [chars] is invalid in [chars] direction for vapid:[dec]. Once the policy is modified, the bssid needs to be reset before the new policy-map definition can take effect

QoS BSSID policy validation failed. Policy will not be installed

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_SSID_POLICY_BIND_ON_AP_FAIL

3-Error

ERROR: Failed to bind SSID policy on AP: [chars] for wlan: [dec], Slot id: [dec] in [chars] direction with status: [chars]

SSID policy bind operation failed.

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-3-QOS_SSID_POLICY_UNBIND_ON_AP_FAIL

3-Error

ERROR: Failed to unbind SSID policy on AP: [chars] for wlan: [dec], Slot id: [dec] in [chars] direction with status: [chars]

SSID policy unbind operation on AP failed.

ewlc-qos

LOG_STD_ACTION

QOS_ERROR_MESSAGE-6-QOS_HA_NO_BSSID_RECORD_SYNC_AP_DELETE

6-Information

Deleting AP %02x%02x.%02x%02x.%02x%02x because BSSID record sync for slotId [dec] wlan_id [dec] pm_dir [chars] failed

QoS BSSID record sync pre-switchover failed. Hence deleting the AP.

ewlc-qos

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-3-ALL_SOURCE_PORT_EXHAUSTED

3-Error

[chars] : Dynamic socket pool limit reached Max : [dec]

All Source ports are exhausted

polaris-aaa

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-3-ALL_SOURCE_PORT_EXHAUSTED_AFTER_CLEANUP

3-Error

[chars] : Dynamic socket pool limit is still at Maximmum [dec] after clean up

All Source port are exhausted even after cleanup

polaris-aaa

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-3-BUFFER_OVERFLOW

3-Error

Radius I/O buffer has overflowed for [chars] with length [dec]

An unusually large number of RADIUS attributes has caused AAA to overflow its RADIUS I/O buffer.

polaris-aaa

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-3-RADIUS_PARSE_FAIL

3-Error

Radius Parse FAIL due to op decode/bad packet

When Radius Parse response op decode/bad packet

polaris-aaa

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-3-RADIUS_TIMER_FAILED_TO_START

3-Error

Failed to start radius timer.

Radius timer failed to start

polaris-aaa

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-3-RADIUS_TIMER_FAILED_TO_STOP

3-Error

Failed to stop radius timer.

Radius timer failed to stop

polaris-aaa

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-3-SECRETDEFINEFAILED

3-Error

Key definition ignored.

The user is attempting to store either a corrupted shared secret or memory allocation failed during secret definition. Any existing shared secret will be preserved.

polaris-aaa

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-3-SOCKET_OPERATION_FAILURE

3-Error

Cannot open UDP socket for service [chars]

The router is unable to open a socket for UDP communications by the indicated service. Most of the time another service might be using the same port.

polaris-aaa

LOG_STD_ACTION

RADIUS_AUDIT_MESSAGE-6-ALLDEADSERVER

6-Information

Group [chars]: No active radius servers found. Id [dec].

This error message occurs when all the servers configured in a server group are found to be unresponsive.

polaris-aaa

LOG_STD_NO_ACTION

RADIUS_AUDIT_MESSAGE-6-BADATTRLIST

6-Information

Unable to process attribute list.

The attribute list is syntactically incorrect.

polaris-aaa

LOG_STD_NO_ACTION

RADIUS_AUDIT_MESSAGE-6-INVALID_PACKET

6-Information

Invalid packet posted to RADIUS.

Radius not able to process a packet as it is invalid

polaris-aaa

LOG_STD_NO_ACTION

RADIUS_AUDIT_MESSAGE-6-RADIUS_ALIVE

6-Information

RADIUS server [chars]:[dec],[dec] is being marked alive.

A RADIUS server that previously was not responding has responded to a new request or the deadtimer has expired.

polaris-aaa

LOG_STD_NO_ACTION

RADIUS_AUDIT_MESSAGE-6-RADIUS_DEAD

6-Information

RADIUS server [chars]:[dec],[dec] is not responding.

The server might not be available to serve request. server has not responded to repeated requests.

polaris-aaa

LOG_STD_NO_ACTION

RADSEC_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_DTLSC_DTLS_REPLAY_ATTACK

3-Error

DTLS replay attack for hostname: [chars]

Detected DTLS replay attack

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_DTLSC_EXT_2_DTLS_SESSION_ESTABLISHED_FAILURE

3-Error

User ID: [chars] Failure to establish a DTLS session with RadSec server, reason: [chars]

Failure to establish a DTLS session with RadSec server

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_RADSEC_SERVER_CERTIFICATE_VALIDATION_FAILURE

3-Error

RADSEC server certificate validation failed with server [chars]

RADSEC server certificate validation failed

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_RADSEC_SERVER_IDENTITY_CHECK_FAILURE

3-Error

RADSEC server identity check failed with server [chars]

RADSEC server identity Check failed

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-3-FIPS_AUDIT_FCS_TLSC_EXT_2_TLS_SESSION_ESTABLISHED_FAILURE

3-Error

User ID: [chars] Failure to establish a TLS session with RadSec server, reason: [chars]

Failure to establish a TLS session with RadSec server

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-6-FIPS_AUDIT_FCS_DTLSC_DTLS_NEGOTIATED_CIPHER

6-Information

Negotiated Cipher is [chars]

Negotiated Cipher during RADSEC HS SUCCESS

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-6-FIPS_AUDIT_FCS_DTLSC_DTLS_SESSION_CLOSED

6-Information

RADSEC DTLS connection closed with peer [chars]

RADSEC DTLS connection closed

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-6-FIPS_AUDIT_FCS_DTLSC_DTLS_SESSION_ESTABLISHED

6-Information

RADSEC DTLS connection established with peer [chars]

DTLS session established message after RADSEC HS SUCCESS

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-6-FIPS_AUDIT_FCS_TLSC_TLS_SESSION_CLOSED

6-Information

RADSEC TLS connection closed with peer [chars]

RADSEC TLS connection closed

ewlc-qos

LOG_STD_ACTION

RADSEC_AUDIT_MESSAGE-6-FIPS_AUDIT_FCS_TLSC_TLS_SESSION_ESTABLISHED

6-Information

RADSEC TLS connection established with peer [chars]

TLS session established message after RADSEC HS SUCCESS

ewlc-qos

LOG_STD_ACTION

REGISTRY-3-FASTCASE_OUT_OF_BOUNDS

3-Error

Attempt made in [chars] to register with out of bounds key

In the FASTCASE registry the key has to be smaller than the size specified when the registry was created. This message indicates that an attempt was made to register with a key which is out of bounds.

iosxe-binos-utils

LOG_STD_ACTION

REGISTRY-3-SEQ_LIST_OVERWRITE

3-Error

Attempt to overwrite a set sequence function ([chars])

A single function can be set as a callback for a specified sequence number for a sequenced list registry. This message indicates that an attempt to set a new callback has failed because a callback function has already been set for this sequence number.

iosxe-binos-utils

LOG_STD_ACTION

REGISTRY-3-STUB_CHK_OVERWRITE

3-Error

Attempt made to overwrite a set stub function in [chars]

A single function can be set as a callback for when a stub with check registry is invoked. This message indicates that an attempt to set a new callback has failed because a callback function has already been set.

iosxe-binos-utils

LOG_STD_ACTION

RFMGR_SYSLOG-4-DCA_CHANNEL_LIST_EMPTY

4-Warning

The DCA Channel list is empty for rf profile [chars]

DCA Channel list is empty It affects Channel Assignment to AP

ewlc-rrm

Please add channels to DCA List

RFMGR_SYSLOG-4-MULTI_BSSID_PROFILE_NOT_FOUND

4-Warning

Invalid Multi bssid profile [chars], applying default-multi-bssid-profile

Invalid multi-bssid-profile is applied, 802.11ax specific payloads are not pushed to AP

ewlc-rrm

Please assign a valid Multi bssid profile

RFMGR_SYSLOG-4-NO_REM_NON_AUTO_RF_CHAN_DCA

4-Warning

WARNING: RF Profile [chars] - Deleting channel [dec] from remove channel list, please add the channel to allowed channel list directly for adding it to DCA Used/Allowed channel list.

Deleting channel from remove channel list adds it to DCA Used/Allowed channel list, but the right way of adding a channel to DCA Used/Allowed channel list is to add the channel directly to allowed channel list by not adding it to remove channel list and then deleting.

ewlc-rrm

Please add the channel directly to allowed channel list for making it part of DCA Used/Allowed channel list

RIF_MGR_FSM-6-GW_REACHABLE_ACTIVE

6-Information

Gateway reachable from Active

Gateway reachable from Active

ewlc-ha

No action is required

RIF_MGR_FSM-6-GW_REACHABLE_STANDBY

6-Information

Gateway reachable from Standby

Gateway reachable from Standby

ewlc-ha

No action is required

RIF_MGR_FSM-6-GW_UNREACHABLE_ACTIVE

6-Information

Gateway not reachable from Active

Gateway not reachable from Active

ewlc-ha

No action is required

RIF_MGR_FSM-6-GW_UNREACHABLE_STANDBY

6-Information

Gateway not reachable from Standby

Gateway not reachable from Standby

ewlc-ha

No action is required

RIF_MGR_FSM-6-RMI_ACTIVE_RECOVERY_MODE

6-Information

Going to Active(Recovery) from Active state

Going to Active(Recovery) From Active

ewlc-ha

No action is required

RIF_MGR_FSM-6-RMI_GW_DECISION_DEFERRED

6-Information

High CPU utilisation on active or standby, deferring action on gateway-down event

High CPU utilisation on active or standby, deferring action on gateway-down event

ewlc-ha

No action is required

RIF_MGR_FSM-6-RMI_LINK_DOWN

6-Information

The RMI link is DOWN.

The redundancy mgmt intf link was down.

ewlc-ha

No action is required

RIF_MGR_FSM-6-RMI_LINK_UP

6-Information

The RMI link is UP.

The redundany mgmt intf link came up

ewlc-ha

No action is required

RIF_MGR_FSM-6-RMI_STBY_REC_TO_STBY

6-Information

Going from Standby(Recovery) to Standby state

Going from Standby(Recovery) to Standby on GW reachable

ewlc-ha

No action is required

RIF_MGR_FSM-6-RMI_STBY_TO_STDBY_REC

6-Information

Going from Standby to Standby(Recovery) state

Going from Standby to Standby(Recovery) on GW unreachable

ewlc-ha

No action is required

RIF_MGR_FSM-6-RMI_STBY_TO_STDBY_REC_REASON

6-Information

Going from Standby to Standby(Recovery) state, Reason: [chars]

Going from Standby to Standby(Recovery) on RP Down event

ewlc-ha

No action is required

RIF_MGR_FSM-6-RMI_STDBY_REC_TO_ACTIVE

6-Information

Going from Standby(Recovery) to Active state

Going from Standby(Recovery) to Active on RP DOWN

ewlc-ha

No action is required

RIF_MGR_FSM-6-RP_LINK_DOWN

6-Information

Setting RP link status to DOWN

RP link status set to DOWN

ewlc-ha

No action is required

RIF_MGR_FSM-6-RP_LINK_UP

6-Information

The RP link is UP.

The redundany port link came up

ewlc-ha

No action is required

RLDP_INITIATE_MESSAGE-6-EWLC_RLDP_INITIATE

6-Information

RLDP initiate [chars]

General ewlc RLDP initiate startup status

iosxe-binos-utils

LOG_STD_ACTION

RM_ERRS-2-ERR_FREE_MEM_CRITICAL

2-Critical

Insufficient free memory for service to work: [dec]

Insufficient free memory for service to handle new connection.

polaris-htx

Disable not required features.

RM_ERRS-4-ERR_INSUFFICIENT_FREE_MEM

4-Warning

Insufficient free memory [dec]

Free memory is lesser than configured for service.

polaris-htx

Disable not required features.

RM_ERRS-6-ERR_RECOVERED_FREE_MEM

6-Information

Recovered, sufficient free memory available [dec]

Required free memory is available now for the service.

polaris-htx

No action is requried

ROGUE_SYSLOG-6-ADHOC_AUTOCONTAIN

6-Information

Adhoc rogue AP with MAC address [chars] has been automatically contained as per WPS policies.

Adhoc Rogue has been automatically contained

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-ADHOC_AUTOCONTAIN_CLEAR

6-Information

Auto-containment for adhoc rogue AP with MAC address [chars] has been stopped.

Adhoc Rogue auto-containment has been stopped

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-AP_AUTOCONTAINED

6-Information

Rogue AP with MAC address [chars] has been automatically contained as per WPS policies

Rogue AP has been auto-contained

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-AP_AUTOCONTAINED_CLEARED

6-Information

Automatic containment for rogue AP with MAC address [chars] has been cleared.

Rogue AP autocontainment has been stopped

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-AP_BEING_CONTAINED

6-Information

Managed AP [chars] with radio MAC [chars] slot [dec] is contained by another AP.

A managed AP is contained by another AP

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-AP_BEING_CONTAINED_CLEAR

6-Information

Managed AP [chars] with radio MAC [chars] slot [dec] is no longer contained by another AP.

A managed AP is no longer contained by another AP

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-AP_CONTAINED_BY_RULE

6-Information

Rogue AP with MAC address [chars] has been contained due to rule [chars] with containment level [dec]

Rogue AP has been contained due to a rule match

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-AP_HONEYPOT

6-Information

Potential Honeypot AP detected with Rogue AP MAC [chars] with SSID [chars] by AP with Radio MAC [chars], slot [dec].

Potential Honeypot AP detected

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-AP_HONEYPOT_CLEAR

6-Information

Potential Honeypot AP MAC address [chars] is cleared. This Rogue AP is no longer advertising an SSID that is configured on this controller.

Potential Honeypot AP cleared

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-AP_IMPERSONATION

6-Information

Impersonation of AP with Radio MAC [chars] using source MAC address [chars] has been detected by AP [chars] with Radio MAC [chars], Slot [dec]

AP impersonation attack has been detected

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-MAX_NUM_ROGUE_AP

6-Information

Rogue AP count for the system has reached the maximum limit of [dec] entries.

Rogue AP maximum scale has been reached

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-MAX_NUM_ROGUE_AP_CLEAR

6-Information

Rogue AP count for the system is within the limit of [dec] entries.

Number of Rogue APs is below system limit

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-MAX_ROGUE_PER_AP

6-Information

The average number of Rogue APs per detecting AP radio has crossed the threshold of [dec] on AP [chars] with radio MAC [chars].

The average number of Rogue APs per detecting AP radio has crossed the threshold.

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-MAX_ROGUE_PER_AP_CLEAR

6-Information

The average number of Rogue APs per detecting AP radio is below the threshold of [dec] on AP [chars] with radio MAC [chars].

The average number of Rogue APs per detecting AP radio is below the threshold.

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-RLDP_ASSOC_FAIL

6-Information

RLDP failed with error code [dec] while trying to associate to Rogue AP [chars] using AP [chars] with Radio MAC [chars], slot [dec].

RLDP failed while trying to associate to Rogue AP

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-ROGUE_AP_CLEARED

6-Information

Rogue AP [chars] removed from Radio MAC [chars], Slot [dec]

The Rogue AP has been removed

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-ROGUE_AP_DETECTED

6-Information

Rogue AP [chars] detected on Radio MAC [chars], Slot [dec], band [chars], Channel [dec], RSSI [dec], SNR [dec], Classification: [chars], State: [chars][chars]

A new Rogue AP has been detected

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-ROGUE_AP_ON_WIRED_NETWORK

6-Information

Rogue AP with MAC address [chars] has been detected on the wired network.

A Rogue AP has been detected on the wired network

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-ROGUE_AP_ON_WIRED_NETWORK_CLEAR

6-Information

Rogue AP with MAC address [chars] is no longer on the wired network.

Rogue AP is not anymore on the wired network

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-ROGUE_CLIENT_DETECTED

6-Information

Rogue client with MAC address [chars] has been detected by [dec] APs, rogue client BSSID [chars], state [chars], last detecting AP [chars], rogue client gateway MAC [chars].

Rogue client detected

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-ROGUE_CLIENT_THRESHOLD_CLEAR

6-Information

Rogue Client [chars] removed from Rogue AP [chars], state [chars], channel [dec], detected by AP [chars], slot [dec], current channel [dec], band [chars]. Rogue client count is now below the threshold for this Rogue AP.

Number of rogue clients per Rogue AP is below the threshold

ewlc-wips

LOG_STD_NO_ACTION

ROGUE_SYSLOG-6-ROGUE_CLIENT_THRESHOLD_EXCEED

6-Information

Rogue Client count threshold exceeded for Rogue AP [chars] by client address [chars] detected by AP [chars], slot [dec], current channel [dec], band [chars], state [chars], rogue AP channel [dec].

Number of rogue clients per Rogue AP threshold has been exceeded

ewlc-wips

LOG_STD_NO_ACTION

ROMMON-5-CPLD_UPGRADE_STATUS

5-Notice

CPLD upgrade: [chars], install-id: [chars], message: [chars]

This syslog provides the result of the CPLD upgrade

cedge-srvcability

No action is required

ROMMON-5-ROMMON_UPGRADE_STATUS

5-Notice

ROMMON upgrade: [chars], install-id: [chars], message: [chars]

This syslog provides the result of the ROMMON upgrade

cedge-srvcability

No action is required

RRM_CLIENT-0-FAILEDTIMERCREATE

0-Emergency

RRM failed to create [chars] timer

Failed to create timer

ewlc-rrm

LOG_STD_ACTION

RRM_CLIENT-3-CHD_INV_RF_PROF

3-Error

Coverage message received profile from [chars]

CHD message was received for a radio which has a non existent RF Profile Configured.

ewlc-rrm

Can be seen during configuration changes,if seen otherwise LOG_STD_ACTION

RRM_CLIENT-3-EWLC_EXEC_ERR

3-Error

%% Error: AP [chars] MAC: %02x%02x.%02x%02x.%02x%02x Slot-id [dec] - [chars]

Improper arguments or config

ewlc-rrm

Arguments to be changed

RRM_CLIENT-3-FAILEDCOVERAGEPROFILE

3-Error

Coverage profile violation on [chars] AP %02x%02x.%02x%02x.%02x%02x Slot: [dec] Failed client count: [dec] Total client count: [dec]

Coverage profile violation

ewlc-rrm

LOG_STD_ACTION

RRM_CLIENT-3-FAILEDINTPROFILE

3-Error

Interference profile violation on [chars] AP %02x%02x.%02x%02x.%02x%02x Slot: [dec] Interference in percentage: [dec] On channel: [dec]

Interference profile violation

ewlc-rrm

LOG_STD_ACTION

RRM_CLIENT-3-FAILEDLOADPROFILE

3-Error

Load profile violation on [chars] AP %02x%02x.%02x%02x.%02x%02x Slot: [dec] Channel load in percentage: [dec] Number of stations: [dec]

Load profile violation

ewlc-rrm

LOG_STD_ACTION

RRM_CLIENT-3-FAILEDNOISEPROFILE

3-Error

Noise profile violation on [chars] AP %02x%02x.%02x%02x.%02x%02x Slot: [dec] Noise: [dec] dBm On channel: [dec]

Noise profile violation

ewlc-rrm

LOG_STD_ACTION

RRM_CLIENT-3-HA_CONFIG_SYNC

3-Error

RRM HA Config tables not yet synced: [chars]

Some critical RRM configuration was found to be missing, immediately after switchover.

ewlc-rrm

If the message appears persistently, RRM may not function as configured. System reboot will be required to restore RRM function

RRM_CLIENT-3-RRM_AP_DB_ERR

3-Error

Unable to find AP %02x%02x.%02x%02x.%02x%02x entry in the database, could not process [chars]

The operation being performed for the AP failed because the internal entry for the AP was not found. It is possible that the AP has been removed from the controller.

ewlc-rrm

Use the 'show ap summary' command to determine if the AP is still joined to the controller. If it is not, the message may be ignored. If it is still joined, restart the AP to ensure that it has the latest configuration and contact technical assistance if the problem recurs.

RRM_CLIENT-3-RRM_AP_INV_SLOT

3-Error

Invalid slot number [dec] for AP %02x:%02x:%02x:%02x:%02x:%02x could not process [chars]

AP included wrong slot number

ewlc-rrm

LOG_STD_ACTION

RRM_CLIENT-3-RRM_AP_TBL_ERR

3-Error

Unable to find AP %02x%02x.%02x%02x.%02x%02x slot [dec] [chars] entry in the database, could not process [chars] event

The operation being performed for the AP failed because the measurement or coverage entry for the radio was not found. recreating the records.

ewlc-rrm

Collect the controller logs and contact technical assistance.

RRM_CLIENT-3-RRM_CHANNEL

3-Error

RRM Channel Config Notification: Radio Role is AUTO. So, channel change is not allowed for AP [chars] on slot [dec].

Channel configuration is not allowed.

ewlc-rrm

LOG_STD_NO_ACTION

RRM_CLIENT-3-RRM_CONFIG

3-Error

RRM Config Notification: [chars]

Some critical RRM configuration still not populated.

ewlc-rrm

If the message appears persistently, for more than 8 times for each phy type, RRM may not function as configured. System reboot will be required to restore RRM function

RRM_CLIENT-5-PASSEDCOVERAGEPROFILE

5-Notice

Coverage profile recovery on [chars] AP %02x%02x.%02x%02x.%02x%02x Slot: [dec]

Coverage profile recovery

ewlc-rrm

LOG_STD_NO_ACTION

RRM_CLIENT-5-PASSEDINTPROFILE

5-Notice

Interference profile recovery on [chars] AP %02x%02x.%02x%02x.%02x%02x: Slot: [dec]

Interference profile recovery

ewlc-rrm

LOG_STD_NO_ACTION

RRM_CLIENT-5-PASSEDNOISEPROFILE

5-Notice

Noise profile recovery on [chars] AP %02x%02x.%02x%02x.%02x%02x Slot: [dec]

Noise profile recovery

ewlc-rrm

LOG_STD_NO_ACTION

RRM_CLIENT-5-RRM_CAC_IN_PROG

5-Notice

AP [chars] slot [dec] [chars] is deferred, till pre-CAC is complete

Setting channel/channel width/channel mode are deferred until pre-CAC is done.

ewlc-rrm

LOG_STD_NO_ACTION

RRM_CLIENT-5-RRM_NON_PSC_CHANNEL

5-Notice

RRM Channel Config Notification: Non-PSC channel [dec] is configured for 6 GHz radio on slot [dec], Clients might fail to connect.

When non PSC channel is used for 6GHz radio, it is possible that 6GHz clients may not be able to join the AP.

ewlc-rrm

LOG_STD_NO_ACTION

RRM_CLIENT-6-MODE_SWITCH_LPI_TO_SP

6-Information

6GHZ Power mode switch from LPI to SP AP %02x%02x.%02x%02x.%02x%02x Slot: [dec] Channel: [dec] Channel Width: [dec]

6GHZ Power mode switch from LPI to SP

ewlc-afc-rrm

LOG_STD_NO_ACTION

RRM_CLIENT-6-MODE_SWITCH_SP_TO_LPI

6-Information

6GHZ Power mode switch from SP to LPI AP %02x%02x.%02x%02x.%02x%02x Slot: [dec] Channel: [dec] Channel Width: [dec]

6GHZ Power mode switch from SP to LPI

ewlc-afc-rrm

LOG_STD_NO_ACTION

RRM_CLIENT-6-PASSEDLOADPROFILE

6-Information

Load profile recovery on [chars] AP %02x%02x.%02x%02x.%02x%02x Slot: [dec]

Load profile recovery

ewlc-rrm

LOG_STD_NO_ACTION

RRM_COMMON_TRACE_MESSAGE-3-RRM_COMMON_INVALID_SLOT

3-Error

Error encountered: [chars]

Invalid slot identifier is found while processing RRM packet

ewlc-rrm

Please report the error to technical support representative

RRM_MGR_DB-5-DUPLICATE_IP_WLC

5-Notice

WLC: [chars] having duplicate IP: [dec].[dec].[dec].[dec] detected while processing RRM pkt. IP address of the conflicting WLC: [chars] should be changed immediately to avoid impact on RRM functionality

Another WLC in the rf-network is having duplicate IP, it will impact RRM functionality for the conflicting controllers

ewlc-rrm

IP address of the conflicting controller should be changed immediately

RRM_MGR_TRACE_MESSAGE-0-FAILEDTIMERCREATE

0-Emergency

RRM failed to create [chars] timer

Failed to create timer

ewlc-rrm

LOG_STD_ACTION

RRM_MGR_TRACE_MESSAGE-3-EWLC_EXEC_ERR

3-Error

%% Error: [chars]

Improper arguments or config

ewlc-rrm

Arguments to be changed

RRM_MGR_TRACE_MESSAGE-3-EWLC_GEN_ERR

3-Error

Error in [chars]

General ewlc Error Message.

iosxe-binos-utils

LOG_STD_ACTION

RRM_MGR_TRACE_MESSAGE-3-HA_CONFIG_SYNC

3-Error

RRM HA Config tables not yet synced: [chars]

Some critical RRM configuration was found to be missing, immediately after switchover.

ewlc-rrm

If the message appears persistently, RRM may not function as configured. System reboot will be required to restore RRM function

RRM_MGR_TRACE_MESSAGE-3-REG_IP_CHG_NOTIFY_FAIL

3-Error

Unable to register with platform to get Management IP Address Change Notification - error [dec].

Unable to register with platform to get Management Interface IP Address Change Notification.

ewlc-rrm

LOG_STD_ACTION

RRM_MGR_TRACE_MESSAGE-3-REG_RX_PKT_FAIL

3-Error

Unable to register with platform to receive packets - error [dec]

Unable to register with platform to receive packets

ewlc-rrm

LOG_STD_ACTION

RRM_MGR_TRACE_MESSAGE-3-RRM_IPC_EP_ERR

3-Error

IPC Failure: [chars]

Failed to find IPC endpoint for AP

ewlc-rrm

If the message appears persistently, RRM will not function as expected. AP should be disconnected to restore RRM function

RRM_MGR_TRACE_MESSAGE-5-RRM_DUPLICATE_IP_WLC

5-Notice

WLC: [chars] having duplicate IP: [chars] detected while processing RRM Hello pkt. IP address of the conflicting WLC: [chars] should be changed immediately to avoid impact on RRM functionality

Another WLC in the rf-network is having duplicate IP, it will impact RRM functionality for the conflicting controllers

ewlc-rrm

IP address of the conflicting controller should be changed immediately

RRM_UTIL-4-INVALIDCHANNELCONFIG

4-Warning

Warning: Update of the channel list caused invalid pair in DCA list for [chars] band

Invalid channel configuration

ewlc-rrm

LOG_STD_NO_ACTION

RRM_UTIL-6-SETCHANNEL

6-Information

Set channel on cell %02x%02x.%02x%02x.%02x%02x: [dec] to [chars] chanwidth [dec] to reduce co-channel interference from [dec] to [dec] Reason [chars]

Set channel to reduce co-channel interference

ewlc-rrm

LOG_STD_NO_ACTION

RRM_UTIL-6-SETCHANNELWIDTH

6-Information

Set channel width on 802.11a for AP %02x%02x.%02x%02x.%02x%02x: failed 160MHz channel width supported only for 4x4 antenna mode

Channel width configuration change

ewlc-rrm

LOG_STD_NO_ACTION

RRM_UTIL-6-SETCHANNEL_DUALBAND

6-Information

Set channel [chars] for AP %02x%02x.%02x%02x.%02x%02x on dual band radio slot: [dec] due to [chars]

Set channel because of Dualband Radio Role/band change

ewlc-rrm

LOG_STD_NO_ACTION

RRM_UTIL-6-SETCHANNEL_ED

6-Information

Set channel on cell %02x%02x.%02x%02x.%02x%02x: [dec] to [chars] due to Air Quality voilation reason [chars]

Set channel because of Air Quality Violation

ewlc-rrm

Investigate the cause of bad air quality on the channel and eliminate if possible

RRM_UTIL-6-SETCHANNEL_NONOPTIMAL

6-Information

Set non-optimal channel on cell %02x%02x.%02x%02x.%02x%02x: [dec] to [chars] because of lack of information

Set channel on user input (non-optimal)

ewlc-rrm

LOG_STD_NO_ACTION

RRM_UTIL-6-SETTXPOWER

6-Information

Tx power changed from [dec] to [dec] for AP %02x%02x.%02x%02x.%02x%02x slot [dec] band [chars] due to [chars]

Set transmit power

ewlc-rrm

LOG_STD_NO_ACTION

RRM_UTIL-6-UPDATECHANNEL

6-Information

Set channel on [chars] AP %02x%02x.%02x%02x.%02x%02x: [dec] to [chars] by configuration change due to [chars]

Channel configuration change

ewlc-rrm

LOG_STD_NO_ACTION

RRM_UTIL-6-UPDATETXPOWER

6-Information

Tx power changed from [dec] to [dec] for AP %02x%02x.%02x%02x.%02x%02x slot [dec] band [chars] due to [chars]

Transmit power configuration change

ewlc-rrm

LOG_STD_NO_ACTION

RULE_ENGINE-3-EWLC_GEN_ERR

3-Error

Error in [chars]

General Wireless LAN Controller Error Message.

iosxe-binos-utils

LOG_STD_ACTION

RULE_ENGINE-3-EWLC_RULE_ENGINE_REGEX_CREATE_ERR

3-Error

Error in [chars]

Rule regular expression error

iosxe-binos-utils

Recreate regular expression correctly

RULE_ENGINE-4-EWLC_RULE_ENGINE_PRIORITY_UPDATE_WARN

4-Warning

Warning: [chars]

rule_engine priorities are overridden, old rule_engine will be invalid

iosxe-binos-utils

LOG_STD_ACTION

SCOOBY-0-SERIAL_BRIDGE_CRITICAL_ERROR

0-Emergency

Reloading [chars] due critical event %#x in block [chars]/[dec] of serial bridge [dec]

A critical serial bridge I/O event has occurred.

asr1k-infra-intrnl

The system automatically reloads the hardware component experiencing the error. If the problem persists, copy the message exactly as it appears on the console or in the system log, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

SCOOBY-0-SERIAL_BRIDGE_CRITICAL_ERROR_RATE

0-Emergency

Reloading [chars] due to critically high serial bridge error rate.

A Serial Bridge has experienced a persistently high error rate. The condition is serious and the card must be reloaded. This could be due to a hardware or software driver defect.

asr1k-infra-intrnl

Copy the message exactly as it appears on the console or in the system log, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

SCOOBY-0-SERIAL_BRIDGE_DRIVER_ERROR

0-Emergency

Kernel Module failed in [chars]

A Serial Bridge has experienced a Init failure. The condition is serious and the card must be reloaded. This could be due to a hardware or software driver defect.

asr1k-infra-intrnl

Copy the message exactly as it appears on the console or in the system log, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

SCOOBY-2-FPGA_VERSION_CHECK_ERR

2-Critical

LEDA FPGA version does not meet minimum required version. [chars]

LEDA FPGA minimum version requirement not met.

asr1k-ether-lc

Copy the message exactly as it appears on the console or in the system log, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

SCOOBY-5-SERIAL_BRIDGE_BLOCK_EVENT

5-Notice

Block [chars]/[dec] of serial bridge [dec] had I/O event %#x

A serial bridge I/O event has occurred. This event is not serious but is logged for diagnostic purposes.

asr1k-infra-intrnl

No user action is required.

SCOOBY-5-SERIAL_BRIDGE_EVENT_RATE

5-Notice

The [chars] event rate of [dec] has exceeded the threshold of [dec] on serial bridge [dec] interconnect [dec]

A Serial Bridge has experienced a high event rate. This condition is not considered serious, but is logged for diagnostic purposes. This could be due to a hardware or software driver defect.

asr1k-infra-intrnl

No user action is required. If this message persists, a serial bridge critical message that needs to be addressed will appear.

SERDES-3-SERDES_CRITICAL_ERROR

3-Error

Critial error [chars] in FRU [chars] when [chars]

A critical error was occurred. The condition is serious and the card must be reloaded. This could be due to bad or unknown hardware (chassis or modules). Chassis Manager could also initialize the Serdes library with incorrect input parameters.

asr1k-infra-intrnl

Copy the message exactly as it appears on the console or in the system log. Collect the output of show platform, show verson, show log, sh diag chassis eeprom detail, show diagnostic slot <slot#> eeprom detail, and any other relevant logs. Contact your Cisco technical support representative.

SERDES-5-SERDES_NOTICE

5-Notice

from FRU [chars], [chars].

CMAN sends a significant Serdes event to IOSD to log it

asr1k-infra-intrnl

No action is required for this notice.

SERVICES-0-INVALID_OWNERSHIP

0-Emergency

Error using service handle %p - invalid ownership (%p, %p)

A multi-thread application is trying to incorrectly use the services library. Applications must follow thread confinement strategy with the services library. Each thread of the application must initialize private managed context of the service library.

iosxe-binos-utils

Copy the error message, tracebacks and version information and contact a Cisco representative.

SERVICES-2-NOINIT

2-Critical

Error initializing services: [chars]

An application failed to initialize the core services library. The application will not be able to communicate with other modules on the system.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

SERVICES-2-NORESOLVE_ACTIVE

2-Critical

Error resolving active FRU: [chars]

An application was not able to determine the active FRU. The application was likely started incorrectly.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

SERVICES-2-NORESOLVE_LOCAL

2-Critical

Error resolving local FRU: [chars]

An application was not able to determine its local FRU. The application was likely started incorrectly.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

SERVICES-2-NORESOLVE_STANDBY

2-Critical

Error resolving standby FRU: [chars]

An application was not able to determine the standby FRU. The application was likely started incorrectly.

iosxe-binos-utils

LOG_STD_RECUR_ACTION

SERVICES-3-INVALID_CHASFS

3-Error

Thread %p has no global chasfs context

A multi-thread application is trying to incorrectly use the services library. Applications must follow thread confinement strategy with the services library. Each thread of the application must initialize private managed context of the service library.

iosxe-binos-utils

Copy the error message, tracebacks and version information and contact a Cisco representative.

SESSION_MGR-0-CONFIG_CORRUPT

0-Emergency

Checksummed interface configuration corruption detected.

Interface configuration field was modified unexpectedly.

polaris-smd

No action is required.

SESSION_MGR-4-ILLEGAL_TRACE_REQ

4-Warning

Component ID [dec] not registered.

Component ID %d not registered.

polaris-smd

No action is required.

SESSION_MGR-4-TERMINATE

4-Warning

Authentication session terminated for client ([chars]) on Interface [chars] AuditSessionID [chars] Reason [chars]

Session is being terminated.

polaris-smd

No action is required.

SESSION_MGR-4-UNAUTH_MOVE

4-Warning

[chars] MAC address ([chars]) from [chars] to [chars]

Move while not authenticated on old IDB

polaris-smd

No action is required.

SESSION_MGR-5-FAIL

5-Notice

Authorization failed or unapplied for client ([chars]) on Interface [chars] AuditSessionID [chars]. [chars] [chars]

Authorization was unsuccessful.

polaris-smd

Authorization was unsuccessful for the client. Collect the smd logs and system console logs

SESSION_MGR-5-MACMOVE

5-Notice

MAC address ([chars]) moved from Interface [chars] to Interface [chars] AuditSessionID [chars]

Client has moved to a new interface without logging off on the previous one.

polaris-smd

No action is required.

SESSION_MGR-5-MACREPLACE

5-Notice

MAC address ([chars]) on Interface [chars] is replaced by MAC ([chars]) AuditSessionID [chars]

A new client has triggered a violation causing an existing client to be replaced

polaris-smd

No action is required.

SESSION_MGR-5-SECURITY_VIOLATION

5-Notice

Security violation on the interface [chars], new MAC address ([chars]) is seen. AuditSessionID [chars]

A host on the specified interface is attempting to gain access into the network or is trying to authenticate in a host mode that does not support the number of hosts attached. This is treated as a security violation and the port has been error-disabled.

polaris-smd

Ensure that the port is configured to support the host count attached. Enter the <cmdbold>shutdown<nocmdbold> command followed by <cmdbold>no shutdown<nocmdbold> command to restart the port.

SESSION_MGR-5-START

5-Notice

Starting '[chars]' for client ([chars]) on Interface [chars] AuditSessionID [chars]

Starting an authentication method

polaris-smd

Message notification informing about the session manager client is being started to authenticate the endpoint attached to the interface

SESSION_MGR-5-SUCCESS

5-Notice

Authorization succeeded for client ([chars]) on Interface [chars] AuditSessionID [chars]

Authorization was successful.

polaris-smd

Client connected to the switch has been successfully authorized by the session manager framework

SESSION_MGR-5-VLANASSIGN

5-Notice

VLAN [dec] assigned to Interface [chars] AuditSessionID [chars]

VLAN assignment to an interface for the session

polaris-smd

No action is required.

SESSION_MGR-7-NOMOREMETHODS

7-Debug

Exhausted all authentication methods for client ([chars]) on Interface [chars] AuditSessionID [chars]

All available authentication methods have been tried

polaris-smd

No action is required.

SESSION_MGR-7-STOPPING

7-Debug

Stopping [chars] for client [chars] on Interface [chars] AuditSessionID [chars]

Stopping the current authentication method

polaris-smd

No action is required.

SHFWD-6-PACKET_TRACE_DONE

6-Information

Packet Trace Complete: [chars]

Packet trace cmd initiated by admin is complete

polaris-platform_mgr

No action is required

SHFWD-6-PACKET_TRACE_FAIL

6-Information

Show fwd is failed at [chars]

Packet trace cmd initiated by admin is fail

polaris-platform_mgr

Collect the trace from all the switch using the cli (show platform software trace fed switch <> )

SHFWD-6-PACKET_TRACE_FLOW_ID

6-Information

Packet Trace Flow id is [dec]

Packet trace instance can be tracked by flowid

polaris-platform_mgr

No action is required

SIF_MGR-1-FAULTY_CABLE

1-Alert

High hardware interrupt seen on switch [dec]\n

The specified stack cable is experiencing high hardware interrupts

iosxe-fwdmgr

Replace the stack cable connected to the stack port.

SIF_MGR-1-FAULTY_STACK_CABLE

1-Alert

High hardware interrupt seen on switch [dec] on stack port [dec]\n

The specified stack cable is experiencing high hardware interrupts

iosxe-fwdmgr

Replace the stack cable connected to the stack port.

SIF_MGR-6-STACK_ADAPTER_INSERTED

6-Information

stack_mgr: Stack adapter [dec] on switch [dec] is inserted

The specific adapter has been inserted from the mentioned switch.

iosxe-fwdmgr

No action is required

SIF_MGR-6-STACK_ADAPTER_REMOVED

6-Information

stack_mgr: Stack adapter [dec] on switch [dec] is removed

The specific adapter has been removed from the mentioned switch.

iosxe-fwdmgr

No action is required

SIG-2-SIG_TUNNEL_EVENT_FAILURE

2-Critical

Cisco Umbrella SIG tunnel: [chars] event failure, [chars]

This syslog is generated when a IPSEC tunnel to Cisco Umbrella Secure Internet Gateway runs into failure(s) during state transition

cedge-sig

No action is required

SIG-2-TUNNEL_TRACKER_STATUS_DOWN

2-Critical

Tracker associated with SIG tunnel [chars] is [chars]

This syslog is generated when tracker(s) associated with SIG tunnel goes DOWN

cedge-sig

No action is required

SIG-2-ZIA_LOCATION_EVENT_FAILURE

2-Critical

Zscaler location: [chars] event failure, [chars] (additional info: [chars])

This syslog is generated when various REST API(s) to setup ZIA encounter errors

cedge-sig

No action is required

SIG-2-ZIA_TUNNEL_EVENT_FAILURE

2-Critical

Zscaler SIG tunnel: [chars] event failure, [chars] (additional info: [chars])

This syslog is generated when a IPSEC/GRE tunnel to Zscaler Secure Internet Gateway runs into failure(s) during state transition

cedge-sig

No action is required

SIG-5-SIG_TUNNEL_EVENT_SUCCESS

5-Notice

Cisco Umbrella SIG tunnel: [chars] event success, [chars]

This syslog is generated when a IPSEC tunnel to Cisco Umbrella Secure Internet Gateway transitions to different states successfully

cedge-sig

No action is required

SIG-5-TUNNEL_TRACKER_STATUS_UP

5-Notice

Tracker associated with SIG tunnel [chars] is [chars]

This syslog is generated when tracker(s) associated with SIG tunnel comes UP

cedge-sig

No action is required

SIG-5-ZIA_LOCATION_EVENT_SUCCESS

5-Notice

Zscaler location: [chars] event success, [chars]

This syslog is generated when various REST API(s) to setup ZIA location succeed

cedge-sig

No action is required

SIG-5-ZIA_TUNNEL_EVENT_SUCCESS

5-Notice

Zscaler SIG tunnel: [chars] event success, [chars]

This syslog is generated when a IPSEC/GRE tunnel to Zscaler Secure Internet Gateway transitions through different states successfully

cedge-sig

No action is required

SIMULATION_ERRMSG-3-rw_err

3-Error

Cosim simualation failed to [chars] %zu bytes. ret: [chars]

An error occurred during cosim rw operation.

INVALID

Check if Cima memory io socket is over subscribbed.

SISF_LOG-3-SISF_TRACEBACK

3-Error

Error in [chars]

General SISF Error Message.

ewlc-sisf

LOG_STD_ACTION

SM-2-INITIALIZATION_FAILED

2-Critical

Session Manager initialization for [chars] failed.

Initialization of session manager process failed.

polaris-infra

Review SM logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log.

SMAN-2-NO_MEMORY

2-Critical

Cannot allocate memory for an internal data structure

An out-of-memory condition occurred when attempting to create an internal data structure. The daemon encountering the problem will exit, after which the process manager will restart.

iosxe-shellmgr

Check the log files for the associated daemon. Monitor processes for excessive memory consumption.

SMAN-2-TDL_MESSAGE

2-Critical

Cannot construct an IPC message for library. The message name is [chars] and the reason is: [chars]

A problem occurred while constructing a type definition language (TDL) message or setting a field in a TDL message. If the problem occurred during construction of a TDL message, the system is out of memory. If the problem occurred while setting a field in the TDL message, there is a library mismatch issue.

iosxe-shellmgr

Check [uipeer] ERR entries in the log files for message reporting problems.

SMAN-3-CRDU_PATCH_REPLY_TIMEOUT

3-Error

Failed to receive patch response from peer process [chars]

During patch operation the Shell Manager broadcasts a request to all affected processes (peers). If a peer does not respond in time then the patch process cannot be completed correctly

polaris-crdu

Check that the process(es) that failed to respond are still active and check their trace files for any potential errors that could prevent them from responding to a patch request in a timely manner

SMAN-3-CRFT_CLEARCOUNTERS_REQUEST_FAIL

3-Error

CRFT clear counters request finished with one or more failures. Check tracelogs for further details.

After a request to clear CRFT counters if any program reports an error or fails to respond within the timeout period this message will be emitted.

polaris-crft

Inspect btrace logs for information about which programs failed and why

SMAN-3-CRFT_COLLECT_REQUEST_FAIL

3-Error

CRFT collection request finished with one or more failures. Check tracelogs for further details.

After a request to collect CRFT data if any program reports an error or fails to respond within the timeout period this message will be emitted.

polaris-crft

Inspect btrace logs for information about which programs failed and why

SMAN-3-CRFT_EXPORT_REQUEST_FAIL

3-Error

CRFT export request finished with one or more failures. Check tracelogs for further details.

After a request to export CRFT data if an error or failure during the export stage occurs this message will be emitted.

polaris-crft

Inspect btrace logs for information about which operation failed and why

SMAN-3-CRFT_RELOAD_REQUEST_FAIL

3-Error

CRFT reload request capture finished with one or more failures. Check tracelogs for further details.

After a request to capture CRFT data on reload if an error or failure during the reload stage occurs this message will be emitted.

polaris-crft

Inspect btrace logs for information about which operation failed and why

SMAN-3-CRFT_UNSUPPORTED_REMOTE_PATH_FAIL

3-Error

CRFT remote requested using an unsupported remote path. Check tracelogs for further details.

After a request to remotely capture CRFT data an error or failure during the remote stage occurs this message will be emitted.

polaris-crft

Inspect btrace logs for information about which operation failed and why

SMAN-3-CRFT_UNSUPPORTED_REMOTE_SCHEME_FAIL

3-Error

CRFT remote requested using an unsupported scheme. Check tracelogs for further details.

After a request to remotely capture CRFT data an error or failure during the remote archive stage occurs this message will be emitted.

polaris-crft

Inspect btrace logs for information about which operation failed and why

SMAN-3-CRFT_UNSUPPORTED_REMOTE_TAG_FAIL

3-Error

CRFT remote requested using an unsupported tag format. Check tracelogs for further details.

After a request to remotely capture CRFT data an error or failure during the remote archive stage occurs this message will be emitted.

polaris-crft

Inspect btrace logs for information about which operation failed and why

SMAN-3-HOSTINFO_MONITOR_FAILURE

3-Error

Error initializing host info monitoring: [chars]

During initialization, the Shell Manager monitors changes to host-related information, such as the hostname. This error occurs if initialization fails.

iosxe-shellmgr

Check the Shell Manager trace file for related details.

SMAN-3-HOSTINFO_READ_FAILURE

3-Error

Error reading host info ([chars]): [chars]

During process startup and when changes occur, the Shell Manager reads host-related information, such as the hostname. This error occurs if there is a failure reading information.

iosxe-shellmgr

Check the Shell Manager trace file for related details.

SMAN-3-INVALID_EPOCH_FILE

3-Error

An upgrade or installation has produced an invalid messaging configuration file [chars], [chars]

During an upgrade or installation of a new package, an invalid messaging configuration file was produced. The file is either empty or has invalid permissions and cannot be read.

iosxe-shellmgr

Repeat the installation or upgrade. If the problem persists, revert to a previous known good package.

SMAN-3-NO_CDL_FILE

3-Error

Could not access command definition file [chars]: [chars]

During initialization, the Shell Manager loads a XML CDL file to load all the CLI structure. This file is for some reason not found.

iosxe-shellmgr

Check the Shell Manager trace file for related details.

SMAN-3-PTL_RENDERER_FAILURE

3-Error

Rendering error with [chars].[chars]. Transform is missing or invalid for data.

The Shell Manager process attempted to render a command response but the transformation failed due to an internal error. The failure may have been caused by a missing transform file or an included file cannot be found. The transformation may also fail if the data returned in the response is binary and has not been processed correctly. In this case, the rendering engine is unable to interpret the data resulting in a failure. The transformation may also fail if there is a mismatch of packages installed on the system. In this case, incompatible messages are exchanged between the Shell Manager and the daemon servicing the command request and incorrect data is passed to the rendering engine.

iosxe-shellmgr

This error indicates a configuration issue resulting from bad or mismatched packages. Review the Shell Manager trace files and log files. Uninstall, then reinstall, any new packages.

SMAN-5-CRFT_CLEARCOUNTERS_REQUEST_SUCCESS

5-Notice

CRFT clear counters completed successfully.

This message serves to inform the user of exactly when the clearcounters operation completes and they are no longer waiting for additional processes

polaris-crft

No action required. This message is expected

SMAN-5-CRFT_COLLECT_REQUEST_INPROGRESS

5-Notice

CRFT collection already in progress. Please try again later

CRFT collection is something that should happen infrequently so if there is already a collection request in progress we reject the incoming request and emit a message to the user informing them that their request is rejected.

polaris-crft

Try the request again later if necessary

SMAN-5-CRFT_COLLECT_REQUEST_NOT_SUPPORTED

5-Notice

CRFT collection request not supported on peer [chars]

Some processes may not support CRFT collection for any of a number of reasons. This message serves to alert the user so that they do not go searching for CRFT stats for the process in question and determine an error has occurred when they cannot find them

polaris-crft

None. Information only.

SMAN-5-CRFT_COLLECT_REQUEST_SUCCESS

5-Notice

CRFT collection completed successfully.

This message serves to inform the user of exactly when the collection completes and they are no longer waiting for additional processes

polaris-crft

No action required. This message is expected

SMAN-5-CRFT_EXPORT_REQUEST_SUCCESS

5-Notice

CRFT export completed successfully.

This message serves to inform the user of exactly when the export operation completes and they are no longer waiting for additional output/feedback

polaris-crft

No action required. This message is expected

SMAN-5-CRFT_RELOAD_REQUEST_SUCCESS

5-Notice

CRFT reload collection completed successfully.

This message serves to inform the user of exactly when the export operation completes and they are no longer waiting for additional output/feedback

polaris-crft

No action required. This message is expected

SPECTRUM-3-EWLC_EXEC_ERR

3-Error

%% Error: AP %02x%02x.%02x%02x.%02x%02x: [chars]

Improper configuration for dual band AP

ewlc-rrm

please check the requested configuration against ap type

SS-2-INITIALIZATION_FAILED

2-Critical

Initialization of [chars] failed for IOx Secure Storage

Initialization of IOx Secure storage process failed.

polaris-infra

Review ioxss logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log.

SSLMGR-0-ASYMMETRIC_KEY_FAIL

0-Emergency

Asymmetric key failure: [chars].

Asymmetric key failure.

iosxe-ssl

No action required - forwarding processor (ESP) rebooted automatically.

SSLMGR-0-N2_VSERVER_FAIL

0-Emergency

Virtual server context failure: [chars].

Cryptographic coprocessor critical operation failed. Further data processing on ESP is halted

iosxe-ssl

forwarding processor (ESP) is rebooted automatically. no action needed

SSLMGR-0-SYMMETRIC_KEY_FAIL

0-Emergency

Symmetric key failure: [chars].

Symmetric key failure.

iosxe-ssl

No action required - forwarding processor (ESP) rebooted automatically.

SSLMGR-3-N2_CONTEXT_FAIL

3-Error

Context failure: [chars].

Coprocessor context operation failed due to resource limit

iosxe-ssl

Monitoring required

SSLMGR-5-GATEWAY_UPDOWN

5-Notice

sslvpn gateway : [chars] changed state to [chars]

sslvpn gateway changed state

iosxe-ssl

ACTION_NONE_REQUIRED

SSLVPNMGR-5-HTTP_REQUEST_NOT_AUTHORIZED

5-Notice

HTTP request without login cookie. [chars]\n

This message indicates that HTTP request doesn't have valid login cookie and is not authorized to access the resource

iosxe-ssl

ACTION_NONE_REQUIRED

SSLVPNMGR-5-LOGIN_AUTH_FAILED

5-Notice

Failed to contact authentication server. [chars]\n

Authentication server is unavailable because it is down or unreachable

iosxe-ssl

Verify if routes are configured correctly to reach authentication and the server is configured correctly

SSLVPNMGR-5-LOGIN_AUTH_PASSED

5-Notice

Authentication successful, user logged in. [chars]\n

This message indicates that login authentication succeeded for user

iosxe-ssl

ACTION_NONE_REQUIRED

SSLVPNMGR-5-LOGIN_AUTH_REJECTED

5-Notice

Failed to authenticate user credentials. [chars]\n

Authentication server failed to validate credentials provided by the user to login under webvpn context

iosxe-ssl

Check username and password configured on authentication server

SSLVPNMGR-5-SSL_CONNECT_OK

5-Notice

SSL/TLS connection successful with client [chars]\n

This message indicates that SSL/TLS handshake with peer was successful

iosxe-ssl

ACTION_NONE_REQUIRED

SSLVPNMGR-6-CONTEXT_MAX_USERS_LOGIN_DENIED

6-Information

Login denied for user [chars]. Max users exceeded for context [chars]\n

This message indicates that user was denied to login because the the max users for the context has been exceeded

iosxe-ssl

Check the gateway configuration and reconfigure the maximum allowed users in the context

SSLVPNMGR-6-GLOBAL_MAX_USERS_LOGIN_DENIED

6-Information

Login denied for user [chars]. Global max users limit reached\n

This message indicates that user was denied to login because the the max users limit reached

iosxe-ssl

ACTION_NONE_REQUIRED

SSLVPNMGR-6-SESSION_TERMINATE

6-Information

Session terminated. [chars]\n

SSLVPN session was terminated

iosxe-ssl

ACTION_NONE_REQUIRED

STACKMGR-1-DUAL_ACTIVE_CFG_MSG

1-Alert

Dual Active Detection [chars]\n

Switch detected availability or unavailability of Dual Active Detection ports.

iosxe-fwdmgr

No action is required

STACKMGR-1-EPA_MISMATCH

1-Alert

[chars]. The mis-match may caused by hardware failure or different EPA types.\n

The Standby EPA mismatch with Active EPA.

iosxe-fwdmgr

Need to make them match

STACKMGR-1-FATAL_ERR

1-Alert

Stack manager encountered an unrecoverable error. [chars]\n

The stack manager process has encountered an unrecoverable error and the switch is being reloaded.

iosxe-fwdmgr

Please ensure valid switch numbers are being used. If you still believe there is an error in the system, please send the system report to a TAC representative

STACKMGR-1-LIC_MISMATCH

1-Alert

License level is [chars] and needs to be upgraded to [chars] for Stackwise Virtual to function.\n

Current Licnese level on active switch does not support Stackwise Virtual.

iosxe-fwdmgr

Need to be upgraded to supported license level

STACKMGR-1-RELOAD

1-Alert

Reloading due to reason [chars]\n

The specified switch has received a reload request and is being reloaded.

iosxe-fwdmgr

No action is required

STACKMGR-1-RELOAD_REQUEST

1-Alert

Received reload request for [chars], reason [chars]\n

The specified switches are being reloaded.

iosxe-fwdmgr

No action is required

STACKMGR-1-STACK_MERGE_IGNORE

1-Alert

Stack Merge Ignored [chars]\n

Switch detected multiple Active switches. But stack-merge is being ignored.

iosxe-fwdmgr

No action is required

STACKMGR-4-SWITCH_ADDED

4-Warning

[chars] [dec] has been added to the stack.\n

The specified switch has been added to the stack.

iosxe-fwdmgr

No action is required

STACKMGR-4-SWITCH_REMOVED

4-Warning

[chars] [dec] has been removed from the stack.\n

The specified switch has been removed from the stack.

iosxe-fwdmgr

No action is required

STACKMGR-5-CHASSIS_ROLE_UPDATE_FAIL

5-Notice

Failed to Set [chars] Chassis [dec] chassis_role [chars]

This is used to indicate that update to new role failed

iosxe-fwdmgr

This is a rare failure condition. Please reach out to TAC

STACKMGR-5-FAST_RELOAD_DONE

5-Notice

Fast reload operation completed successfully on entire stack

This is used to indicate that the fast reload on stack is complete.

accsw-p-fsu

No action needed. This is not an error.

STACKMGR-6-ACTIVE_ELECTED

6-Information

[chars] [dec] has been elected ACTIVE.\n

The specified switch has been elected active.

iosxe-fwdmgr

No action is required

STACKMGR-6-ACTIVE_READY

6-Information

Active [chars] [dec] is ready.\n

The active switch is ready.

iosxe-fwdmgr

No action is required

STACKMGR-6-CHASSIS_ADDED

6-Information

[chars] [dec] has been added to the stack.\n

The specified chassis has been added to the stack.

iosxe-fwdmgr

No action is required

STACKMGR-6-CHASSIS_READY

6-Information

[chars] [dec] is ready.\n

The specified chassis is ready.

iosxe-fwdmgr

No action is required

STACKMGR-6-CHASSIS_REMOVED

6-Information

[chars] [dec] has been removed from the stack.\n

The specified chassis has been removed from the stack.

iosxe-fwdmgr

No action is required

STACKMGR-6-CHASSIS_REMOVED_KA

6-Information

[chars] [dec] has been removed from the stack due to keepalive failure. \n

Chassis has been removed due to the keepalive failure.

iosxe-fwdmgr

No action is required

STACKMGR-6-DISC_DONE

6-Information

[chars] [dec] has finished stack discovery.\n

The specified switch has completed stack discovery and is moving to the election phase.

iosxe-fwdmgr

No action is required

STACKMGR-6-DISC_START

6-Information

[chars] [dec] is starting stack discovery.\n

The specified switch is starting stack discovery.

iosxe-fwdmgr

No action is required

STACKMGR-6-KA_MISSED

6-Information

Keepalive missed for [dec] times for [chars] [dec] \n

Chassis has been removed due to the keepalive failure.

iosxe-fwdmgr

No action is required

STACKMGR-6-STACK_LINK_CHANGE

6-Information

Stack port [dec] on [chars] [dec] is [chars]\n

The specified stack port has changed status.

iosxe-fwdmgr

No action is required

STACKMGR-6-STANDBY_ELECTED

6-Information

[chars] [dec] has been elected STANDBY.\n

The specified switch has been elected standby.

iosxe-fwdmgr

No action is required

STACKMGR-6-SWITCH_READY

6-Information

[chars] [dec] is ready.\n

The specified switch is ready.

iosxe-fwdmgr

No action is required

SUBSYS-3-SUBSYS_CLASS

3-Error

[chars] subsystem [chars] has class [chars]

The task has detected a subsystem which has an unsupported class in its header.

iosxe-binos-utils

LOG_STD_ACTION

SUBSYS-3-SUBSYS_RECURSION

3-Error

[chars] subsystem [chars] maxiumum sequence depth [dec] exceeded

The task has detected that a subsystem upon insertion has exceeded the depth of insertion.

iosxe-binos-utils

LOG_STD_ACTION

SUBSYS-3-SUBSYS_VERSION

3-Error

[chars] subsystem [chars] has unsupported version: [dec]

The task has detected a subsystem which has an unsupported version in its header.

iosxe-binos-utils

LOG_STD_ACTION

SUBSYS-6-SUBSYS_SEQUENCE

6-Information

[chars] subsystem [chars] has cross class sequence for [chars]

The task has detected a subsystem which has an incorrect class for which it is being considered for.

iosxe-binos-utils

LOG_STD_ACTION

SUBSYS-6-SUBSYS_UNORDERED

6-Information

Subsystem class [dec] ([chars]) has no order

The task has detected a class which has an unknown order upon initialization.

iosxe-binos-utils

LOG_STD_ACTION

SWITCH-3-L2_L3_CONVERT

3-Error

Failed to convert interface [chars] into an [chars] port

An error occured while changing the port mode from L2 to L3 or vice versa.

iiot-rtr-platform

Try reloading the device. If the reload fails to correct the problem, collect the output of the error message, the logs and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

SYSHW-3-SYSHW_READ

3-Error

A read operation has failed for device: [chars] error: [chars]

A syshw read operation failed for the mentioned device

polaris-infra

The error message indicates a read failure for the device. No action is needed from the user. However, if these errors come continuously or frequently, it may indicate permanent fault with the specific device/component.

SYSHW-3-SYSHW_REG_READ

3-Error

A register read operation has failed for device: [chars] register: [chars] error: [chars]

A syshw register read operation failed for the mentioned device

polaris-infra

The error message indicates a read failure for the device. No action is needed from the user. However, if these errors come continuously or frequently, it may indicate permanent fault with the specific device/component.

SYSHW-3-SYSHW_REG_WRITE

3-Error

A register write operation has failed for device: [chars] register: [chars] error: [chars]

A syshw register read operation failed for the mentioned device

polaris-infra

The error message indicates a read failure for the device. No action is needed from the user. However, if these errors come continuously or frequently, it may indicate permanent fault with the specific device/component.

SYSHW-3-SYSHW_WRITE

3-Error

A write operation has failed for device: [chars] error: [chars]

A syshw write operation failed for the mentioned device

polaris-infra

The error message indicates a write failure for the device. No action is needed from the user. However, if these errors come continuously or frequently, it may indicate a permanent fault with the specific device/component.

SYSPLAT-3-PLIM_BRIDGE_CRITICAL_ERROR

3-Error

Reloading [chars] due critical event %#x in block [chars]/[dec] of PLIM device

A critical PLIM device I/O event has occurred.

asr1k-infra-intrnl

The system automatically reloads the hardware component experiencing the error. If the problem persists, copy the message exactly as it appears on the console or in the system log, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

SYSPLAT-3-PLIM_CRITICAL_ERROR_RATE

3-Error

Reloading [chars] due to critically high PLIM device error rate.

A Serial Bridge has experienced a persistently high error rate. The condition is serious and the card must be reloaded. This could be due to a hardware or software driver defect.

asr1k-infra-intrnl

Copy the message exactly as it appears on the console or in the system log, collect the output of show tech-support and any other relevant logs, and contact your Cisco technical support representative.

SYSPLAT-5-PLIM_BLOCK_EVENT

5-Notice

Block [chars]/[dec] of PLIM device had I/O event %#x

A PLIM device I/O event has occurred. This event is not serious but is logged for diagnostic purposes.

asr1k-infra-intrnl

No user action is required.

SYSPLAT-5-PLIM_EVENT_RATE

5-Notice

The [chars] event rate of [dec] has exceeded the threshold of [dec] on interconnect [dec]

A Serial Bridge has experienced a high event rate. This condition is not considered serious, but is logged for diagnostic purposes. This could be due to a hardware or software driver defect.

asr1k-infra-intrnl

No user action is required. If this message persists, a PLIM device critical message that needs to be addressed will appear.

SYSTEM-2-REBOOT_ABORTED

2-Critical

System reboot aborted due to [chars]

This syslog is generated when system reboot is aborted due to an error

cedge-install

If reboot is aborted due to software error, please contact Cisco TAC

SYSTEM-4-SSL_CERT_WARNING

4-Warning

SSL certificate warning: [chars] (code: [chars])

This syslog is generated when self-signed certificates are used for communication. Self signed certificates are not considered secure and must be replaced with certificates provided by verified distributors

cedge-install

Customers are expected to delete self-signed certificates and replace with them Enterprise certificates

SYSTEM-5-REBOOT_ISSUED

5-Notice

System reboot issued, reason: [chars]

This syslog is generated when system reboot is issued

cedge-install

No action is required

SYSTEM-5-SOFTWARE_INSTALL_STATUS

5-Notice

Software install stage: [chars], install-id: [chars], message: [chars]

This syslog is generated during software installation which goes through multiple stages

cedge-install

No action is required

SYSTEM-6-CLI_COMMIT

6-Information

CLI commit done by user [chars]

This info syslog is generated when a user alters config via CLI. CLI is usually locked when a device is managed by Cisco SD-WAN Manager, however when the control connection is down, CLI session is unlocked for users and user can commit via CLI

vip-vdaemon

No action is required

SYSTEM_CONFIG_MESSAGE-2-AP_FILE_TRANSFER_HTTPS_CUST_PORT

2-Critical

CRITICAL, [chars]

General WLC critical message

iosxe-binos-utils

LOG_STD_ACTION

SYSTEM_CONFIG_MESSAGE-3-ACL_FLEX_ERR

3-Error

Error in [chars]

ewlc ACL flex push error message.

iosxe-binos-utils

LOG_STD_ACTION

SYSTEM_CONFIG_MESSAGE-3-ACL_INDEX_ERR

3-Error

Error in [chars]

ewlc ACL flex index error message.

iosxe-binos-utils

LOG_STD_ACTION

SYSTEM_CONFIG_MESSAGE-5-UNSUPPORTED_FLEX_ACL_RULE

5-Notice

Unsupported rule: [chars], in flex acl: [chars]

unsupported rule in flex acl

iosxe-binos-utils

LOG_STD_ACTION

TAGMGR_DB_SYSLOG-3-TAGMGR_RF_TAG_CREATE_ERROR

3-Error

Failure during RF tag [chars] creation, could not add to rf profile tag list

Failed to add RF tag to RF profile tag list

ewlc-rrm

Please delete the RF tag and configure again

TAGMGR_TRACE_MSG-3-TAG_EASY_PSK_CONFIG_WARNING

3-Error

Easy-PSK config validation error: [chars]

Easy-PSK CONFIG warning message

ewlc-spwifi

LOG_STD_ACTION

TAGMGR_TRACE_MSG-3-TAG_MPSK_CONFIG_WARNING

3-Error

MPSK config validation error: [chars]

MPSK CONFIG warning message

ewlc-ap

LOG_STD_ACTION

TAGMGR_TRACE_MSG-4-TAG_CONFIG_WARNING

4-Warning

Warning: [chars]

General Wireless LAN Controller warning message

ewlc-ap

LOG_STD_ACTION

TAGMGR_TRACE_MSG-5-WLC_MODE_CHANGE

5-Notice

Mode Change: [chars]

Msg indicating AP reboot during Mode Change

ewlc-ap

LOG_STD_ACTION

TDLDB-3-DATABASE_MEMORY_LEAK

3-Error

Database memory leak detected in [chars] database, [chars]/[chars]/[chars] size: [dec] bytes

A memory leak has been detected in the database memory. The leaked object is identified by name

iosxe-p-db

LOG_STANDARD_ACTION

TDLDB-3-DBPERSIST_OPERATION_FAILURE

3-Error

Operation: [chars], DB: [chars], Failure reason: [chars]

Database persistent operation can be triggered by 1. Persist : write memory or reload CLI 2. Delete : write erase CLI 3. Restore : During boot time, when database is first opened When error occurs, it can impact the customer in this way 1. Persist : DB content can not be persisted, data will be lost after system reload. If reload CLI command fails, it does not allow the system getting reloaded. 2. Delete : There may be database residue in the persistent storage media. 3. Restore : Persistent content cab be lost

iosxe-p-db

LOG_STD_ACTION

TDLDB-3-INVALID_TABLE_FREE

3-Error

Invalid table free by process [chars] in [chars] on table with luid [chars]

In shared databases, only the garbage collector should be performing table and record deletes on tables that have read cursors enabled. A non-gc process has performed a table deletion.

iosxe-p-db

LOG_STD_ACTION

TDLDB-3-SESSION_LOCK_TIMEOUT

3-Error

Owner: user-proc: [chars], DB: [chars]. Lock expired [chars] ago.

An application running in a process wishes to have an exclusive write access to DB. It acquires a session lock with for a specific period and is expected to release or renew the session lock. The appication has failed to do so and hence the unexpected timeout has occured

polaris-infra

This is unexpected. Report this to Cisco TAC.

TDLDB-3-WRITE_ON_SNAPSHOT

3-Error

Process writing on snapshotted DB [[chars]]

Application is trying to write on a snapshotted DB. A snapshotted DB is read-only and any write operation is not effective.

polaris-mdt-infra

LOG_STD_ACTION

TDLDB-4-LONG_READ_WRITE_LOCK_HELD

4-Warning

Process held [chars] lock on DB [[chars]] for [[dec]] ns

Application has held the read/write lock for fairly long time. If this error is thrown, it means that the lock has been held for more than 1 sec.

iosxe-p-db

LOG_STD_ACTION

TDLDB-6-DBPERSIST_OPERATION_INFO

6-Information

Cancelled [chars] operation and is intended - DB: [chars], Reason: [chars]

When this message is observed, the reason can be 1. DB format version mismatched - database format definition can be changed. If mismatched, the operation is cancelled and this is an intended behavior. 2. DB base pointer mismatched - database base pointer can be modified. If changed, the operation is cancelled and this is an intended behavior.

iosxe-p-db

LOG_STD_ACTION

TDLDB-6-SUBSCRIPTION_DAMPENING_INACTIVE

6-Information

Subscription dampening inactive for DB [chars] on table [chars]. All on-change updates for the table will be sent. Consider re-adjusting the dampening period

On-change Subscription enabled with dampening will be temporarily in-active due to load on system or due to incorrect dampening interval configured.

iosxe-p-db

LOG_STD_ACTION

TDLDB-6-SUBSCRIPTION_DAMPENING_REACTIVATE

6-Information

Dampening subscription re-activated for DB [chars] on table [chars]

On-change Subscription re-activated with dampening resumed after it got paused

iosxe-p-db

LOG_STD_ACTION

THERMAL-1-THERMAL_GREEN_THRESHOLD

1-Alert

Hotspot temperature has exceeded GREEN threshold\n

The switch is too cold.

polaris-platform_mgr

Check the switch's environment is a safe operating temperature. If problem persists, replace the switch.

THERMAL-1-THERMAL_RED_THRESHOLD

1-Alert

Hotspot temperature has exceeded RED threshold. Switch will shutdown soon.\n

The hotspot temperature is critically overheated. The switch will soon shutdown to prevent permanent damage.

polaris-platform_mgr

Check the switch's environment is a safe operating temperature. If problem persists, replace the switch.

THERMAL-2-THERMAL_YELLOW_THRESHOLD

2-Critical

Hotspot temperature has exceeded YELLOW threshold\n

The hotspot temperature is too high. Improve cooling immediately.

polaris-platform_mgr

Check the switch's environment is a safe operating temperature. If problem persists, replace the switch.

TH_WARN_MGR-2-WIRELESS_CLIENTS_THRESHOLD_CLEAR

2-Critical

Current percentage of joined wireless clients ([dec]) returned below the configured threshold ([dec])

The number of clients currently joined to the wireless controller returned below the configured threshold for the device

iosxe-binos-utils

If this message occurs, you need to carefully check if you need a more capable controller for the number of wireless clients you are trying to serve

TH_WARN_MGR-2-WIRELESS_CLIENTS_THRESHOLD_HIT

2-Critical

Current percentage of joined wireless clients ([dec]) exceeded the configured threshold ([dec])

The number of clients currently joined to the wireless controller has exceeded the configured threshold for the device

iosxe-binos-utils

If this message occurs, you need to carefully check if you need a more capable controller for the number of wireless clients you are trying to serve

TIMINGD-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-IPC_CONNECTION_INVALID

0-Emergency

An IPC connection has invalid state.

An IPC connection has an invalid state. This could be due to a software defect or system resource exhaustion.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-IPC_CONNECT_MASTER

0-Emergency

IPC connection to the active RSP failed because [chars]

IPC connection to the active RSP failed. This could be due to a software defect or system resource exhaustion.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-IPC_INITIALIZATION

0-Emergency

IPC initialization failed because [chars]

IPC initialization failed. This could be due to a software defect or system resource exhaustion.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-MESSAGE_REGISTER

0-Emergency

Failed to register with active RSP because [chars]

The active RSP failed to register.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-MESSAGE_RELAY

0-Emergency

Failed to relay a message because [chars]

Failed to relay a message. This could be due to a software defect or system resource exhaustion.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-MESSAGE_RESPONSE

0-Emergency

An invalid message response was received because [chars]

An invalid message response was received. This could be due to a software defect or system resource exhaustion.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-MQIPC_ADVANCE

0-Emergency

Failed to advance MQIPC queue because [chars]

The MQIPC initialization failed.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-MQIPC_INITIALIZATION

0-Emergency

MQIPC initialization failed because [chars]

MQIPC initialization failed. This could be due to a software defect or system resource exhaustion.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-PEER_TABLE

0-Emergency

A peer table initialization or maintenance function failed because [chars]

A peer table initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

iiot-rtr-timing

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

TIMINGD-0-RESOURSE

0-Emergency

Resource allocation failed in [chars] because [chars]

The system is unable to allocate the requested resource.

iiot-rtr-timing

In most cases, this message is seen as a result of a temporary resource issue. Retry the request for the resource when the system is experiencing lower traffic volumes. If the message persists, reload the router using the reload command.

TLSCD-4-DNS_RESOLVER_FAILURE

4-Warning

DNS resolver failed for url [chars] session [chars].

The TLS Client daemon attempted to resolve the server url and API is failing/timing out. The failure may have been caused by a miss configuration of nameserver or url string in crypto tls-tunnel configuration. Daemon shall be retrying to resolve the url periodically.

iosxe-p-tlscdinfra

This error indicates a configuration issue for url resolution.

TLSCD-4-TPS_CERT_RESP_FAILURE

4-Warning

TPS certificate response failed for session session [chars].

The TLS Client daemon process attempted to get the ceritificate from IOSd and API is failing/timing out. The failure may have been caused by a miss configuration of pki trustpoint crypto tls-tunnel configuration.

iosxe-p-tlscdinfra

This error indicates a configuration issue for pki trustpoint.

TLSCD-5-SESSION_UPDOWN

5-Notice

Session [[chars]] to TLSGW: [[chars]] is [chars].

The TLS Client daemon process session status notification.

iosxe-p-tlscdinfra

The TLS Client daemon process session status.

TTYMON-3-AGETTY

3-Error

Cannot initiate a switch in console ownership. A required program could not be launched successfully.

The Host Manager process on the Route Processor, and only the Route Processor, is responsible for determining which process has control of the console port, either IOSd or an IOSXE process. A user can initiate a switch in ownership by by entering the 'send break' command at a telnet prompt to switch from IOSd to a shell instance. Control is returned to IOSd by exiting the shell instance. Switching ownership of the console port is initiated by the user entering a 'send break' command at a telnet prompt. The Host Manager launches one or more programs to authenticate users and to provide a shell instance. One or more of these programs has not been configured correctly.

iosxe-binos-utils

Some required programs are either not available or not configured correctly or are failing for some reason. If this occurs after a recent upgrade it is possible that the upgrade has corrupted the current installation.

TTYMON-3-CHASFS

3-Error

The software which monitors ownership of the console port cannot [chars] a filesystem configuration value.

The Host Manager process on the Route Processor, and only the Route Processor, is responsible for determining which process has control of the console port, either IOSd or an IOSXE process. A user can initiate a switch in ownership by by entering the 'send break' command at a telnet prompt to switch from IOSd to a shell instance. Control is returned to IOSd by exiting the shell instance. The component within the Host Manager responsible for monitoring a change of console ownership uses the filesystem to store various settings. This error indicates that the daemon encountered a problem either reading or writing a value from/to the filesystem.

iosxe-binos-utils

Check the log files for the Host Manager and search for entries related to 'ttymon' and 'chasfs' and this should give an indication as to why the operation failed. Check available resources and see if other daemons are also experiencing problems with the chassis filesystem since this may indicate a more pervasive problem. If so the reboot the box.

TTYMON-3-INIT

3-Error

The software which monitors ownership of the console port cannot be initialized correctly

The Host Manager process on the Route Processor, and only the Route Processor, is responsible for determining which process has control of the console port, either IOSd or an IOSXE process. A user can initiate a switch in ownership by by entering the 'send break' command at a telnet prompt to switch from IOSd to a shell instance. Control is returned to IOSd by exiting the shell instance. The component within the Host Manager responsible for this has encountered an initialization error and console monitoring is no longer available.

iosxe-binos-utils

Check the status of the Host Manager process. Check the Host Manager log files for further indications as to why the initialization failed and if necessary restart the machine.

U to Z

Facility-Severity-Mnemonic

Severity-Meaning

Message

Message-Explanation

Component

Recommended-Action

UBD-0-EVENT_LIBRARY

0-Emergency

An event facility initialization or maintenance function failed because [chars]

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion.

polaris-infra

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered inforation to a Cisco technical support representative.

UBD-0-MQIPC_ADVANCE

0-Emergency

Failed to advance MQIPC queue because [chars]

The MQIPC initialization failed.

polaris-infra

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

UBD-0-MQIPC_INITIALIZATION

0-Emergency

MQIPC initialization failed because [chars]

MQIPC initialization failed. This could be due to a software defect or system resource exhaustion.

polaris-infra

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

UBD-2-INITIALIZATION_FAILED

2-Critical

URSA Bootstrap initialization for [chars] failed.

Initialization of ursa bootstrap process failed.

polaris-infra

Review UBOOTD logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log.

UICFGEXP-3-LIBRARY_ERROR

3-Error

Error loading library '[chars]': [chars]

A configuration message was received which required a library to be loaded. The library failed to load.

iosxe-ui

LOG_STD_ACTION

UICFGEXP-3-MESSAGE_ERROR

3-Error

Unable to process message for '[chars]': [chars]

A message was received by the configuration export module which could not be processed. The message has been discarded.

iosxe-ui

LOG_STD_ACTION

UICFGEXP-3-SYMBOL_ERROR

3-Error

Error loading library symbol '[chars]' from '[chars]': [chars]

A configuration message was received which required a library to be loaded. The library failed to load all required symbols.

iosxe-ui

LOG_STD_ACTION

UICFGEXP-3-WRITE_FAILED

3-Error

Unable to write configuration for '[chars]': [chars]

The configuration export module failed to write the server configuration files. The server configuration change has not occurred.

iosxe-ui

LOG_STD_ACTION

UICFGEXP-6-SERVER_NOTIFIED_START

6-Information

Server [chars] has been notified to start

The server has been notified to start.

iosxe-ui

LOG_STD_NO_ACTION

UICFGEXP-6-SERVER_NOTIFIED_STOP

6-Information

Server [chars] has been notified to stop

The server has been notified to stop.

iosxe-ui

LOG_STD_NO_ACTION

UIPEER-2-TDL_MESSAGE

2-Critical

Cannot construct an IPC message for library. The message name is [chars] and the reason is: [chars]

A problem occurred while constructing a type definition language (TDL) message or setting a field in a TDL message. If the problem occurred during construction of a TDL message, then the system is out of memory. If the problem occurred while setting a field in the TDL message, there is a library mismatch issue.

iosxe-binos-utils

Check [uipeer] ERR entries in the log files for message reporting problems.

UIPEER-3-INVALID_DEBUG_MESSAGE

3-Error

The peer process was unable to process an incoming message for 'debug all' from the shell-manager

When the 'debug all' command is issued, the Shell Manager broadcasts a notification of the command request to its peers. If the notification message has been corrupted or incorrectly created, the peers cannot complete the requested operation.

iosxe-binos-utils

Check the trace files for the Shell Manager failed process. Restart the system.

UIPEER-3-INVALID_EPOCH_MESSAGE

3-Error

The peer process was unable to process an incoming epoch update message from the shell-manager

For each new type definition language (TDL) epoch, the Shell Manager broadcasts a change notification message to its peers. If the Shell Manager's message is incorrect or corrupt, the peers are unable to identify the new epoch. In this case, the peers reject the proposed epoch.

iosxe-binos-utils

Check the trace files for the Shell Manager failed process. Check or undo any recently installed packages, then restart the system.

UIPEER-3-INVALID_HOSTINFO_MESSAGE

3-Error

The peer process was unable to process an incoming message for host info from the shell-manager

When host information, such as the hostname, changes, the Shell Manager broadcasts a notification of the change to its peers. If the notification message has been corrupted or incorrectly created, the peers cannot complete the requested operation.

iosxe-binos-utils

Check the trace files for the Shell Manager failed process. Restart the system.

UIPEER-3-NO_PEER

3-Error

A process was unable to retrieve a shell-manager peer handle.

A process was attempting to communicate with the Shell Manager daemon using the integrated [uipeer] component. The error occurred because the peer instance could not be found.

iosxe-binos-utils

Check [uipeer] ERR entries in the log files for message reporting problems.

UIPEER-3-SET_LOG_TRACELOG_NUM

3-Error

Tracelog number for process [chars] changed to [dec]

Tracelog number to keep for a process is changed using set logging tracelog-number .. CLI

polaris-trace

No action is required. This is informational message

UIPEER-5-TIMER_ACCURACY_TEST

5-Notice

Timer Accuracy Test [chars].

Test result of Timer Accuracy Test

iosxe-binos-utils

No action is required. This is informational message

UPGRADE-3-AP_SW_UPDATE_ERR_LOG_MSG

3-Error

AP SW update [chars]

AP Software Update logging

ewlc-upgrade

AP software update failed. ISSU image upgrade or SMU patching could be aborted. The user needs to initiate ISSU upgrade/SMU patch again. If the error occured during manual operation, operation can be initiated again

UPGRADE-3-AP_UPGRADE_CLEAR_REPORT_NAME_ERROR

3-Error

AP Upgrade clear report error, failed to find upgrade report name : <[chars]> from upgrade report table

Error occured in deleting record from upgrade report table. Operation aborted.

ewlc-upgrade

LOG_STD_ACTION

UPGRADE-3-AP_UPGRADE_CLEAR_REPORT_NAME_IN_PROGRESS_ERROR

3-Error

Staggered AP Upgrade in progress, failed to delete upgrade record with report name : <[chars]> from upgrade report table

Error occured in deleting record from upgrade report table. Operation aborted.

ewlc-upgrade

LOG_STD_ACTION

UPGRADE-3-AP_UPGRADE_FALLBACK_ERROR

3-Error

AP Upgrade fallback error

Error occured in upgrade fallback process. Operation aborted.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-3-AP_UPGRADE_FALLBACK_INIT_TIMEOUT

3-Error

Timeout occurred either source controller is not responding or has responded with invalid software version. Aborting fallback process

Timeout occurred. Source controller is not responding to the upgrade fallback version request message or it has responded with an invalid software version. Aborting fallback process

ewlc-upgrade

Please reload source controller with valid image and initiate upgrade process from destination controller by using CLI: 'ap image move destination <Destination Name> <Destination IPv4/IPv6 address> <Report name>'

UPGRADE-3-AP_UPGRADE_FALLBACK_TYPE_MSG_ERROR

3-Error

AP upgrade process aborted. Failed to send fallback type message to peer

Error occured while sending fallback type message to peer. Operation aborted.

ewlc-upgrade

Please restore the mobility status between source and destination controller

UPGRADE-3-AP_UPGRADE_FALLBACK_VERSION_VALIDATION_FAILURE

3-Error

Source controller is not responding or has responded with invalid software version

Source controller is not responding to the upgrade fallback version request message or it has responded with an invalid software version

ewlc-upgrade

Please reload source controller with valid image

UPGRADE-3-DESTINATION_NOT_READY

3-Error

Destination controller not ready. Aborting upgrade process

Destination controller may be going through another AP upgrade or move

ewlc-upgrade

Please wait for the current ap upgrade to finish before triggering this command.

UPGRADE-3-DESTINATION_NOT_RESPONDING

3-Error

AP upgrade process aborted. Destination controller is not responding

Destination controller is not responding to the upgrade request message

ewlc-upgrade

Destination Controller may be down or unreachable. Please restore the mobility status between source and destination controllers before initiation of AP move/upgrade to destination

UPGRADE-3-MOBILITY_TUNNEL_DOWN

3-Error

AP upgrade process aborted. Mobility tunnel is down for more than the permissible amount of time

If the mobility tunnel with the peer is down for more than the permissible amount of time, the current upgrade process is aborted

ewlc-upgrade

Please restore the mobility status between source and destination controllers before initiation of AP move/upgrade to destination

UPGRADE-3-STAGGERED_UPGRADE_ABORT_DEST_ERROR

3-Error

Trigger abort CLI from source WLC, fail to abort AP upgrade

AP upgrade abort CLI should be triggered from source WLC.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-3-STAGGERED_UPGRADE_ABORT_ERROR

3-Error

Staggered AP Upgrade not in progress, fail to abort AP upgrade

Error occured in AP upgrade abort process. Operation aborted.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-3-STAGGERED_UPGRADE_ERROR

3-Error

Staggered AP Upgrade error: [chars]

Error occured in upgrade reset process. Operation aborted.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-3-STAGGERED_UPGRADE_IN_PROGRESS

3-Error

AP upgrade is in progress. New ap upgrade process is not allowed

If an ap upgrade process is already running, either in source or destination mode, new ap upgrade process is not allowed

ewlc-upgrade

Please wait for the current ap upgrade to finish before triggering this command.

UPGRADE-3-STAGGERED_UPGRADE_MOVE_REPORT_ERROR

3-Error

Invalid ap upgrade report name

Upgrade report name entered is invalid

ewlc-upgrade

Please enter a valid ap upgrade report name.

UPGRADE-5-AP_SW_UPDATE_LOG_MSG

5-Notice

AP SW update [chars]

AP Software Update logging

ewlc-upgrade

No action required

UPGRADE-5-AP_UPGRADE_AP_RESET_FAILURE

5-Notice

AP with MAC: [chars] has not rejoined after software upgrade. No longer accounting for this AP

AP has not rejoined the controller

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-5-AP_UPGRADE_EVENT

5-Notice

Staggered AP upgrade event: [chars]

Staggered AP upgrade event message

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-5-AP_UPGRADE_SITE_FILTER_ANY_IGNORE

5-Notice

Site-filters for any-image will be ignored for APSP/APDP.

Site-filters added with any-image are only applicable for N+1 upgrades.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-5-AP_UPGRADE_SSO_FAILURE

5-Notice

Staggered AP upgrade was interrupted due to SSO. The upgrade process will continue shortly.

Staggered AP upgrade was interrupted due to SSO. The process should restart automatically

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-AP_UPGRADE_ANY_IMAGE_DB_DELETE

6-Information

Site-filters added with image name 'any' deleted.

Existing site-filters with image name 'any' are deleted.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-AP_UPGRADE_AP_RESET

6-Information

AP: [chars] has incorrect software. AP is going for reset.

AP is going for a software upgrade

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-AP_UPGRADE_CLEAR_REPORT_NAME

6-Information

AP Upgrade record deleted successfully

Deleted AP upgrade record.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-AP_UPGRADE_DB_DELETE

6-Information

Site filters for APSP deleted for the image version [chars]; new image version is [chars]

Existing site-filters for APSP are deleted since the base image is upgraded.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-AP_UPGRADE_FALLBACK_COMPLETE

6-Information

AP Upgrade fallback process completed succesfully

AP Upgrade fallback process completed

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-AP_UPGRADE_FALLBACK_START

6-Information

AP Upgrade fallback process started

Starting AP upgrade fallback process

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-STAGGERED_UPGRADE_ABORT

6-Information

Aborted AP Upgrade successfully

Aborted AP upgrade process.

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-STAGGERED_UPGRADE_ABORT_DEST

6-Information

Aborted AP Upgrade forcibly on destination controller

AP upgrade was forcibly stopped on destination controller by the user

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-STAGGERED_UPGRADE_COMPLETE

6-Information

Staggered AP Upgrade completed succesfully

All APs in current upgrade process rebooted with the new version

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-STAGGERED_UPGRADE_START

6-Information

Staggered AP Upgrade reboot process started

Rebooting given APs in staggered way

ewlc-upgrade

LOG_STD_NO_ACTION

UPGRADE-6-STAGGERED_UPGRADE_WITH_RESET_FALLBACK_COMPLETE

6-Information

Staggered AP Upgrade with fallback type as either reset or reset with fallback completed succesfully

All APs in current upgrade process rebooted with the new version

ewlc-upgrade

LOG_STD_NO_ACTION

VDAEMON-3-NO_ACTIVE_VBOND

3-Error

Device does not have an active connection to SD-WAN validator

This error syslog is generated when there are no active control connections to Cisco SD-WAN Validator. This could be a temporary situation where control connections flap because of some network issue. This could also imply some issue with SD-WAN Validator

vip-vdaemon

If the issue persists, i.e. control connections to SD-WAN Validator do not come up for long, use vdiagnose utility to identify the reason

VDAEMON-3-NO_ACTIVE_VSMART

3-Error

Device does not have an active connection to SD-WAN Controller

This error syslog is generated when there are no active control connections to Cisco SD-WAN Controller. This could be a temporary situation where control connections flap because of some network issue. This could also imply some issue with SD-WAN Controller(s)

vip-vdaemon

If the issue persists, i.e. control connections to SD-WAN Controller(s) do not come up for long, use vdiagnose utility to identify the reason

VDAEMON-3-NO_SDWAN_MODE

3-Error

Device does not suppport SD-WAN control mode

This error syslog is generated when SD-WAN Edge virtual machine is instantiated on an unsupported hypervisor

vip-vdaemon

Please check SD-WAN documentation on which all hypervisors are supported for SD-WAN mode

VDAEMON-5-CONTROL_CONN_STATE_CHANGE

5-Notice

Control connection to [chars] [chars] (TLOC: [chars]/[dec]/[chars] via [chars]) is [chars]

This notice syslog is generated when control connection to Cisco SD-WAN Validator, Controller or Manager goes down or comes back up

vip-vdaemon

No action is required

VDAEMON-5-PEER_AUTH_FAILED

5-Notice

Auth failed for [chars] ([chars]), reason: [chars]. Control connection attempt via [chars] (color: [chars])

This notice syslog is generated when control connection to peer device (Cisco SD-WAN Validator, Manager or Controller) cannot be established due to various reasons

vip-vdaemon

Please refer to https://www.cisco.com/c/en/us/support/docs/routers/sd-wan/214509-troubleshoot-control-connections.html for troubleshooting control connection failures

VDAEMON-6-DOMAIN_ID_CHANGED

6-Information

Domain id changed from [dec] to [dec] via config

This info syslog is generated when domain-id is changed via config

vip-vdaemon

No action is required

VDAEMON-6-IPSEC_REKEY

6-Information

IPSec SA [chars] rekey done for tunnel established via [chars] (color: [chars])

This info syslog is generated when auto/manual IPSEC rekey is initiated for tunnels established over a WAN interface

vip-vdaemon

No action is required

VDAEMON-6-ORG_NAME_CHANGED

6-Information

Organization name changed from [chars] to [chars]

This info syslog is generated when organization name is changed via config

vip-vdaemon

No action is required

VDAEMON-6-SITE_ID_CHANGED

6-Information

Site id changed from [dec] to [dec] via config

This info syslog is generated when site-id is changed via config

vip-vdaemon

No action is required

VDAEMON-6-SYSTEM_IP_CHANGED

6-Information

System IP changed from [chars] to [chars] via config

This info syslog is generated when system IP is changed via config

vip-vdaemon

No action is required

VDAEMON-6-SYSTEM_LICENSE_MISMATCH

6-Information

There is a license association mismatch. [chars] instance is being associated to [chars] license

This info syslog is generated when there is a license association mismatch. Pay As You Go instance cannot be associated with Bring Your Own instance or vice versa

vip-vdaemon

Contact Cisco TAC for assistance

VDAEMON-6-TLOC_IP_CHANGE

6-Information

Control connection TLOC changed from [chars]:[dec] to [chars]:[dec]

This info syslog is generated when TLOC IP and port changes as a result of static configuration change, DHCP renewal or when the edge device learns about public IP/port via Cisco SD-WAN Catalyst validator (which behaves as STUN server in such cases)

vip-vdaemon

No action is required

VDAEMON-6-VMANAGE_CONNECTION_PREF_CHANGED

6-Information

vManage connection preference for interface: [chars] (color: [chars]) changed to [dec]

This info syslog is generated when vmanage connection prefernce value for a WAN interface is changed via config

vip-vdaemon

No action is required

VIP_CONFD-3-VIP_CONFD_ERR_LOG

3-Error

vip-confd logging : [chars]

vip-confd error log:

cedge-bootstrap

The vip-confd process console logging.

VIP_CONFD-5-VIP_CONFD_NOTICE_LOG

5-Notice

vip-confd logging : [chars]

vip-confd notice log:

cedge-bootstrap

The vip-confd process console logging.

VMAN-2-ACTIVATION_STATE

2-Critical

[chars] '[chars]' [chars] [chars]

The activation state of the named virtual service has changed as notified by Virt-manager.

vman

In the failed case, check Virt-manager's logs for the cause of the failure. In the successful case, this notification can be ignored.

VMAN-2-ALLOC_VIRT_INST_RCS

2-Critical

Virtual Service[chars]

A memory allocation request failed to allocate a data structure required to activate the virtual service.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-COMMIT_VIRT_INST_RCS

2-Critical

Virtual Service[chars]

The request to commit the resources required by the named virtual service failed.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-CPUSHARES_LIMIT

2-Critical

Virtual Service[chars]

The virtual service machine definition file is requesting more CPU shares than the system has available for virtual services.

vman

Deactivate any other virtual services to free up CPU share resources and activate this virtual service. If that does not address the problem, then enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-CPUTUNES_INTERNAL_ERROR

2-Critical

Virtual Service[chars]

Virt-manager and its associated infrastructure experienced an internal error.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-CPUTUNES_SHARES_LIMIT

2-Critical

Virtual Service[chars]

The virtual service machine definition file is requesting more CPU shares than the system has available for virtual services.

vman

Deactivate any other virtual services to free up CPU share resources and activate this virtual service. If that does not address the problem, then enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-CREATE_VIRT_INST_ENTRY

2-Critical

Virtual Service[chars]

The request to create a DB entry for the named virtual service failed.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-DEACT_FOR_ISSU

2-Critical

[chars] Max ([dec]s)

An ISSU event is pending. Any active VMs will be automatically deactivated to allow ISSU preprocessing to validate the environment. Any ISSU-deactivated VMs will be automatically restarted if the ISSU is cancelled.

vman

None. Allow the ISSU to continue and the VMs will restart when the ISSU completes; or cancel the ISSU and vman will automatically restart the VMs.

VMAN-2-DEFER_VIRT_INST_PROC

2-Critical

Virtual Service[chars]

The final activation processing failed to successfully defer.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-DISK_IMAGE_PATH

2-Critical

Virtual Service[chars]

The virtual service machine definition file contains an invalid disk image path for one of the disk devices. This may be a Harddisk, CDROM or USB storage device.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-FIND_VIRT_INST_ENTRY

2-Critical

Failed to find virtual service with id [dec] in the Virt-manager DB

The virtual service with the ID named could not be located in the Virt-manager DB.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-GENERAL_FAILURE

2-Critical

Virtual Service[chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

VMAN-2-GUESTSHELL_ENABLED

2-Critical

The guest shell has been enabled. The command '[chars]' may be used to access it, '[chars] destroy' to remove it.

Informs the user that the guest shell virtual service has been enabled (which is done by default).

vman

The user may use or remove the guest shell with the commands specified.

VMAN-2-HA_STATE

2-Critical

[chars] [chars] [chars] [chars]

VMAN tries to detect the role/slot of various nodes on HA events from the platform. If any of those event callbacks fail, this notification would be raised.

vman

In the failed case, check Virt-manager's logs for the cause of the failure. Check for the HA event error msg and root cause the same.

VMAN-2-HA_SWITCHOVER_STATE

2-Critical

[chars] [chars] [chars] [chars]

VMAN HA switchover state related messages for a virtual-service whilst it is being recovered on newly active RP after a HA switchover.

vman

In the failed case, check Virt-manager's logs for the cause of the failure. Check for the HA event error msg and root cause the same.

VMAN-2-HA_SYNC_ERR

2-Critical

[chars] '[chars]' [chars]

The ha-sync persistent storage disk for the virtual service cannot be watched for sync to standby RP.

vman

Collect the Virt-manager logs and scan them for the cause.

VMAN-2-HA_SYNC_THREAD_STATE

2-Critical

HA remote sychronize thread has failed and exited.

VMAN tries to remote sync the OVA repository to all online nodes using a separate thread. If that thread fails, this notification would be raised.

vman

In the failed case, check Virt-manager's logs for the cause of the failure. Check for the pthread error msg and root cause the same.

VMAN-2-INCONSISTENT_CPUTUNES_CONFIG

2-Critical

Virtual Service[chars]

The virtual service machine definition file is requesting invalid CPU tunes parameter.

vman

Use a different valid machine definition file for the virtual service. If the problem persists, then enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-INCONSISTENT_MEM_CONFIG

2-Critical

Virtual Service[chars]

The virtual service machine definition file is inconsistent in the specification of required memory via the <memory> and <currentMemory> nodes.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-INSERT_VIRT_INST_ENTRY

2-Critical

Virtual Service[chars]

Inserting the named virtual service into the virtual service DB tracked by Virt-manager failed.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-INSTALL_FAILURE

2-Critical

Virtual Service[chars]

The installation of the virtual service failed.

vman

Enable the Virt-manager trace logs and repeat the installation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-INSTALL_LOG

2-Critical

[chars] [chars] [chars] [chars]

The installation log of the named virtual service, is to provide more information about long running operation, that could affect the control of CLI

vman

No action is required

VMAN-2-INSTALL_MEDIA_RETRY

2-Critical

VMAN, VM install media still unavailable.[chars]

The install media was not detected. Waiting for udev to complete install media(harddisk) detection.

vman

After VMAN exceeds the maximum retry limit, verify if install media (harddisk) is accessible and retry the installation again.

VMAN-2-INSTALL_STATE

2-Critical

[chars] '[chars]'[chars] [chars]

The installation state of the named virtual service has changed as notified by Virt-manager.

vman

In the failed case, check Virt-manager's logs for the cause of the failure. In the successful case, this notification can be ignored.

VMAN-2-INVALID_ACT_MSG

2-Critical

Virtual Service[chars]

The virtual service activate message was received, however, the data it contained could not be interpreted

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-INVALID_DEACT_MSG

2-Critical

Failed to process virtual service deactivate message

The virtual service deactivate message was received, however, the data it contained could not be interpreted

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-INVALID_PACKAGE

2-Critical

Virtual Service[chars]

The package definition file for the named virtual service has failed to be validated and the virtual service will not run

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause. The most likely cause would be that the package file has been corrupted during file transfer. The suggested action would be to redo the file transfer.

VMAN-2-INVALID_UNPROV_MSG

2-Critical

Failed to process virtual service unprovision message

The virtual service unprovision message was received, however, the data it contained could not be interpreted

vman

Enable the Virt-manager trace logs and repeat the activation followed by deactivation and then unprovision of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-MACHINE_TYPE_NOT_SUPPORTED

2-Critical

Virtual Service[chars]

The virtual service cannot be activated as the machine type specified is not supported

vman

Enable the support for the machine type and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-MACH_PARSE_FAILURE

2-Critical

Virtual Service[chars]

The named virtual service has an invalid parameter specified in the .xml file inside the .ova package

vman

Fix the .xml file inside the .ova package to have valid values. Then retry installing and activating it

VMAN-2-MEMORY_LIMIT

2-Critical

Virtual Service[chars]

The virtual service machine definition file is requesting more memory than the system has available for virtual services.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-MEMORY_LIMIT_WARN

2-Critical

Virtual service ([chars])[chars] defines [dec] MB of Memory exceeding the maximum [dec] MB.

The virtual service machine definition file is requesting more memory for the specified profile, than the system has available for virtual services.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-MORETHANONE_CPUTUNES_CONFIG

2-Critical

Virtual Service[chars]

The virtual service machine definition file is requesting more than one CPU tunes parameter.

vman

Use a different valid machine definition file for the virtual service. If the problem persists, then enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-MOVE_STATE

2-Critical

[chars] '[chars]' [chars] [chars]

The move of the core or log file of the named virtual service has as been successful or failed as notified by Virt-manager.

vman

In the failed case, check Virt-manager's logs for the cause of the failure. In the successful case, this notification can be ignored.

VMAN-2-NETWORK_CONFIG_ERROR

2-Critical

Virtual Service[chars]

A network configuration error has been detected for the named virtual service.

vman

No action is required

VMAN-2-PROCESS_PKG_DEF

2-Critical

Virtual Service[chars]

The virtual service package for the named virtual service has failed to be validated and the virtual service will not run.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-PROC_INT_LIST

2-Critical

Virtual Service[chars]

The interface list embedded in the activate request for the named virtual service could not be processed.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-REMOVE_VIRT_INST_ENTRY

2-Critical

Virtual Service[chars]

Removing the named virtual service from the virtual service DB tracked by Virt-manager failed.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-RESET_FORCE

2-Critical

Virtual Services non-recoverable reset command processed

A 'virtual service reset force' command has been entered and processed. This action initiates a cleanup of last resort. Occasionally a VM will get into an unrecoverable state that prevents it from activating but also from uninstalling. This is a rare event but when it happens the only resort may be to remove the .conf control file and reboot, which forces a cleanup of all previously installed VM files and artifacts. Note that once this command is used, current VMs are considered to be in an unstable or unpredictable state, and all future install, uninstall, upgrade, and activation commands will be blocked.

vman

Once the command is entered and accepted, there is no recourse but to restart the system.

VMAN-2-RESIZE_OPER_STATE

2-Critical

Virtual service '[chars]' [chars][chars] to '[dec]' [chars]

VMAN attempts to resize various VM parameters like rootfs size, CPU share, memory if requested by user. Success/failure status messages for these resize operations are communicated by this syslog.

vman

In the failed case, check Virt-manager's logs for the cause of the failure. Check for the HA event error msg and root cause the same.

VMAN-2-RSYNC_STATE

2-Critical

[chars] [chars] [chars] [chars]

VMAN tries to remote sync the virtual-instance configuration file and the OVA repository to all online nodes. If rsync fails even after consecutive retries, this notification would be raised.

vman

In the failed case, check Virt-manager's logs for the cause of the failure. Check for the rsync error code and root cause the same.

VMAN-2-SET_VTX_ROMVAR_SPACE

2-Critical

Failed to set ROM monitor variable ENABLE_VTX: No space in table

Failed to set ENABLE_VTX ROM monitor variable due to no space in Monitor Variable Table.

vman

Verify number of entries in Monitor Variable Table.

VMAN-2-SET_VTX_ROMVAR_STRING

2-Critical

Failed to set ROM monitor variable ENABLE_VTX: Invalid string format: [chars]

Failed to set ENABLE_VTX rom monitor variable due to invalid string format.

vman

Verify format of string from error message.

VMAN-2-START_FAILED

2-Critical

Virtual Service[chars]

The named virtual service failed to start.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-UNINSTALL_ALL_VMS

2-Critical

All Virtual Services are being uninstalled [chars][chars] [chars]

All virtual services are being uninstalled by Virt-manager.

vman

Examine the reason given as to why all virtual services are being uninstalled for more information. If the reason indicated is due to some error condition, check Virt-manager's logs for the cause of the failure.

VMAN-2-UPGRADE_LOG

2-Critical

[chars] [chars] [chars] [chars]

The upgrade log of the named virtual service, is to provide more information about long running operation, that could affect the control of CLI

vman

No action is required

VMAN-2-VCPU_INVALID

2-Critical

Virtual Service[chars]

The virtual service machine definition file is requesting invalid VCPU value.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-VCPU_LIMIT

2-Critical

Virtual Service[chars]

The virtual service machine definition file is requesting more VCPUs than the system has reserved for virtual services.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-VIRT_INST_CRIT

2-Critical

VIRTUAL SERVICE [chars] LOG: [chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

VMAN-2-VIRT_INST_DISK

2-Critical

Virtual Service[chars]

The virtual service requires Disk Storage in excess of the Free Disk Storage available to virtual services.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-VIRT_INST_INTERFACE

2-Critical

Virtual Service[chars]

The number of configured virtual port group interfaces must match the number of Ethernet Network Interfaces defined in the machine definition file

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-VIRT_INST_LOG_UNTHROTTLE

2-Critical

Failed to unthrottle the log for virtual service [chars]

The named virtual service had sent overwhelming sys log messages and its log had been throttled as a result, but system has failed to unthrottle it for some reason.

vman

For debugging collect the virt-manager logs and scan them for the cause.

VMAN-2-VIRT_INST_MEMORY

2-Critical

Virtual Service[chars]

The virtual service requires physical memory in excess of the free memory available to virtual services.

vman

Enable the Virt-manager trace logs and repeat the activation of the virtual service. Collect the Virt-manager logs and scan them for the cause.

VMAN-2-VIRT_INST_MGMT_INTERFACE

2-Critical

Virtual service [chars] has no management interface defined but it is configured in CLI.

A management interface is configured but none is defined.

vman

Deactivate the virtual service, remove the management interface configuration CLI, and reactivate the virtual-service.

VMAN-2-VIRT_INST_STATE

2-Critical

Virtual Service[chars]

The named virtual service has failed. It is no longer running either because the guest OS has failed, the guest OS has shut down the machine or the emulator has failed.

vman

An attempt at restarting the virtual service can be made from the IOS configuration by doing a no activate/activate. For debugging collect the Virt-manager logs and scan them for the cause.

VMAN-3-PSS_ERR

3-Error

Purpose: [chars], URI: [chars], errcode: [dec]

Persistent Storage Service handling error

vman

Collect the Virt-manager logs and scan them for the cause.

VMAN-3-PSS_SNAPSHOT_ERR

3-Error

Source URI: [chars], Destination URI: [chars], errcode: [dec]

Persistent Storage Service snapshot error

vman

Collect the Virt-manager logs and scan them for the cause.

VMAN-3-SDWRAP_ERR

3-Error

Description: [chars], errcode: [dec]

Debug infrastructure error

vman

Collect the Virt-manager logs and scan them for the cause.

VMAN-3-VIRT_INST_ERR

3-Error

VIRTUAL SERVICE [chars] LOG: [chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

VMAN-4-HA_SYNC_NEEDED

4-Warning

If using the guest shell, please use 'guestshell sync' if you want to preserve state on standby in case of supervisor switchover

Message notifying user that he needs to manually synchronize the Virtual service contents to standby supervisor in order to preserve these contents in case of a supervisor switchover. Currently only applicable to the guest shell

vman

User can type the 'guestshell sync' command on active supervisor to synchronize it's contents to the standby supervisor if desired.

VMAN-4-PACKAGE_SIGNING_LEVEL_CHANGED

4-Warning

Package signing level changed from allow '[chars]' to allow '[chars]'

The package certificate signing level global setting has been changed via configuration under the virtual-service global sub-mode.

vman

Ensure that this setting has been changed as expected by an authorized user.

VMAN-4-UPDATE_WARNING

4-Warning

Virtual Service[chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

VMAN-4-VIRT_INST_WARN

4-Warning

VIRTUAL SERVICE [chars] LOG: [chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

VMAN-4-VIRT_SERV_LIBVIRTD_WARN

4-Warning

VMAN not able to connect to the libvirt daemon after '[dec]' attempts

VMAN has been unable to connect to the libvirt daemon. Virtualization services will not be available until this connection is made.

vman

Collect the logs produced by 'show virt tech'

VMAN-4-WATCHDOG_TIMER

4-Warning

[chars] '[chars]' [chars] [chars]

The watchdog timer configured for the named virtual service has expired.

vman

Check any logs produced by the virtual service to determine the cause.

VMAN-5-AUX

5-Notice

Virtual Service[chars]

The AUX login to a virtual service may allow the user access to system functions that may not have been tested or may interact with the system in unintended ways. Use with caution.

vman

No action is required

VMAN-5-PACKAGE_SIGNING_LEVEL_ON_INSTALL

5-Notice

Package '[chars]' for service container '[chars]' is '[chars]', [chars] '[chars]'

A service container software package with the certificate signing level described is being installed.

vman

Take note of the service container and software package. Verify the software package is expected to be (un)signed as described and has the appropriate contents. Uninstall the package if unsure of the package origins.

VMAN-5-PERMISSION_DENIED

5-Notice

Virtual Service '[chars]' is not owned by client IOSd

An attempt was made to modify a virtual-service that is not owned by by the client. The request was rejected.

vman

No action is required.

VMAN-5-VIRT_INST

5-Notice

LOG FROM VIRTUAL SERVICE [chars]: [chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

VMAN-5-VIRT_INST_NOTICE

5-Notice

VIRTUAL SERVICE [chars] LOG: [chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

VMAN-6-VIRT_INST_INFO

6-Information

VIRTUAL SERVICE [chars] LOG: [chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

VMAN-7-VIRT_INST_DEBUG

7-Debug

VIRTUAL SERVICE [chars] LOG: [chars]

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.

vman

No action is required

WDAD_TRACE_MESSAGE-3-WLC_REGULATORY_FILE_PROCESS_ERR

3-Error

Error : [chars]

Error in regulatory file processing

ewlc-rrm

LOG_STD_ACTION

WDAD_TRACE_MESSAGE-4-WLC_REGULATORY_FILE_PROCESS_WARN

4-Warning

Warning: [chars]

Regulatory file processing warning message

ewlc-rrm

LOG_STD_ACTION

WDAD_TRACE_MESSAGE-5-WLC_REGULATORY_FILE_PROCESS_NOTICE

5-Notice

Notice : [chars]

Regulatory file processing notice message

ewlc-rrm

LOG_STD_ACTION

WEBSERVER-5-CONNECTION_FAILED

5-Notice

connection failed from host [chars] - [chars]

Failure reason for SSL connection

ng-web-infra

No action is required

WEBSERVER-5-LOGIN_FAILED

5-Notice

Login Un-Successful from host [chars]

Login unsuccessful when user/password is invalid

ng-web-infra

No action is required

WEBSERVER-5-LOGIN_PASSED

5-Notice

Login Successful from host [chars] by user '[chars]'

Login successful

ng-web-infra

No action is required

WEBSERVER-5-MAX_CONNECTION_REACHED

5-Notice

HTTP server maximum connection reached '[dec]'

Maximum HTTP connection reached.

ng-web-infra

No action is required

WEBSERVER-5-SESS_LOGOUT

5-Notice

Successfully logged out from host [chars] by user '[chars]'

Logout successful

ng-web-infra

No action is required

WEBSERVER-5-SESS_TIMEOUT

5-Notice

Session timeout from host [chars] by user '[chars]'

Session Timeout

ng-web-infra

No action is required

WEBSOCKET_SPACES-3-WS_ONBOARDING_DISCONNECTING

3-Error

Onboarding websocket to cisco-spaces is disconnecting for reason:[chars]

Onboarding websocket to cisco-spaces is disconnecting

spaces-oa

If this message occurs, it means onboarding websocket to cisco-spaces is disconnecting

WEBSOCKET_SPACES-3-WS_ONBOARDING_ERR

3-Error

Onboarding websocket to cisco-spaces could not be established for error:[chars]

Onboarding websocket to cisco-spaces could not be established due to errors

spaces-oa

If this message occurs, it means onboarding websocket to cisco-spaces could not be established due to errors

WEBSOCKET_SPACES-6-WS_ONBOARDING_DISCONNECTED

6-Information

Onboarding websocket to cisco-spaces is disconnected

Onboarding websocket to cisco-spaces is disconnected

spaces-oa

If this message occurs, it means Onboarding websocket to cisco-spaces is disconnected

WEBSOCKET_SPACES-6-WS_ONBOARDING_SUCCESS

6-Information

Onboarding websocket to cisco-spaces is successfully established

Onboarding websocket to cisco-spaces is successfully established

spaces-oa

If this message occurs, it means onboarding websocket to cisco-spaces is successfully established

WEBUI-6-INSTALL_OPERATION_INFO

6-Information

User: [chars], Install Operation: [chars] [chars]

This message is used to indicate that an install operation is being performed via WebUI

web-ui-wireless

No action required. This is not an error, it is a log message that an install operation is being performed via WebUI

WLANMGR_TRACE_MESSAGE-2-EWLC_WLANMGR_CRIT_ERR

2-Critical

Wlanmgr Error: [chars]

Wlanmgr ewlc Error Message.

iosxe-binos-utils

LOG_STD_ACTION

WLANMGR_TRACE_MESSAGE-2-EWLC_WLANMGR_CRIT_ERR_TRACE

2-Critical

WLANMGR Error: [chars]

WLAN configs are not getting pushed to Access points. Make a note of any recent changes made to the network or the device configuration which may have triggered this and proceed to the suggested action.

iosxe-binos-utils

Copy the error message exactly as it appears on the console or in the system log. Open a case with the Technical Assistance Center via the Internet http://www.cisco.com/cgi-bin/front.x/case_tools/caseOpen.pl, or contact your Cisco technical support representative and provide the representative with the gathered information. It is suggested to collect archive traces and live process core to analyse the error.

WLANMGR_TRACE_MESSAGE-3-EWLC_WLANMGR_SCHEDULED_WLAN_DISABLE

3-Error

WLANs associated with policy profile [chars] are disabled by calendar profile [chars]

Wlanmgr scheduled WLAN disable message.

iosxe-binos-utils

LOG_STD_ACTION

WLANMGR_TRACE_MESSAGE-3-EWLC_WLANMGR_SCHEDULED_WLAN_ENABLE

3-Error

WLANs associated with policy profile [chars] are enabled by calendar profile [chars]

Wlanmgr scheduled WLAN enable message.

iosxe-binos-utils

LOG_STD_ACTION

WLANMGR_TRACE_MESSAGE-4-EWLC_WLANMGR_WARN

4-Warning

Wlanmgr Warning: [chars]

Wlanmgr ewlc Warning Message.

iosxe-binos-utils

LOG_STD_ACTION

WNCD_ERROR_MESSAGE-3-WNCD_CONFIG_DONE_IPC_FAILURE

3-Error

Error: IPC failure to notify wncmgrd on config_done event.

Critical notification to allow AP join

ewlc-app-infra

LOG_STD_ACTION

WNCD_EWC_ERRMSG-6-INSTALL_CLEANUP_INFO

6-Information

INSTALL cleanup after switchover: [chars]

General EWC WNCD message

ewcap-image

LOG_STD_ACTION

WNCMGRD_ERROR_MESSAGE-3-BULK_SYNC_FAIL

3-Error

Error: Bulk sync not complete. Reloading the WLC!

Switchover happened before bulk sync is complete!

ewlc-ha

LOG_STD_ACTION

WNCMGRD_ERROR_MESSAGE-3-HA_PAIR_ERROR

3-Error

Error: Number of wncd instances mismatched between active and standby; HA function will not function correctly.

Resource provision is different on active and standby

ewlc-ha

LOG_STD_ACTION

WSA_ICAP_MESSAGE-3-EWLC_WSA_ICAP

3-Error

%% Error: ICap: [chars]

General ewlc ICap config failure

iosxe-binos-utils

LOG_STD_ACTION

WUILOGIN-2-AUTHENTICATION_SYSTEM_FAILED

2-Critical

WebUI standalone authentication process failed. Reason: [chars]

During the id and password validation phase of the wuilogin access module authentication attempt, an exception occurred. This message usually occurs as a result of a failure of the underlying PAM authentication module.

iosxe-binos-utils

Note the time of the error and check the web user interface log (wuilogin-*.log) for additional information on why the attempt to access the web user interface failed.

WUILOGIN-2-INITIALIZATION_FAILED

2-Critical

WebUI standalone login initialization failed.

The attempt to access the web user interface using the wuilogin access module failed. The wuilogin access module is used to authenticate web user interface access only when the IOS integrated webserver, which is enabled using the ip http server command, or the IOS process is down or disabled.

iosxe-binos-utils

Note the time of the error and check the web user interface log (wuilogin-*.log) for additional information on why the attempt to access the web user interface failed.

Additional References

Technical Assistance

When the recommended action of an error message advises that you contact Cisco technical support, open a case with the Cisco Technical Assistance Center (TAC).

Description

Link

The Cisco Support website provides extensive online resources, including documentation and tools for troubleshooting and resolving technical issues with Cisco products and technologies.

To receive security and technical information about your products, you can subscribe to various services, such as the Product Alert Tool (accessed from Field Notices), the Cisco Technical Services Newsletter, and Really Simple Syndication (RSS) Feeds.

Access to most tools on the Cisco Support website requires a Cisco.com user ID and password.

https://www.cisco.com/c/en/us/support/index.html