TORSwitch Information mandatory table if you want to enter ToR information
|
Click + to add information for ToR Switch.
Name
|
Description
|
Host Name
|
ToR switch name.
|
VPC Peer Keepalive
|
Peer Management IP.
|
VPC Domain
|
Do not define if there is no
|
Node ID
|
Integer, unique across all switches |
Click Save
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
NFVBench
|
Enable check box which by default is false.
Add ToR information connected to switch:
-
Select a ToR Switch and enter the Switch name.
-
Enter the port number. For example: eth1/5
-
NIC Ports: INT1 and INT2 optional input, enter the two port numbers of the 4-port 10G Intel NIC at the management node used for NFVBench.
For mechanism driver VPP, there are two optional fields in NFVBENCH if network option is available:
-
VTEP IPs: Mandatory for NFVBench with VXLAN. It must be comma separated IP pair in vxlan-tenant network, but not in the tenant pool.
-
VNIs: Mandatory for NFVBench with VXLAN, and must be comma separated vnid_id pairs.
For mechanism driver VTS:
VTEP IPs: Mandatory for VTS/VXLAN only. It must be comma separated IP pair belonging to tenant network segment, but not in the tenant
network pool.
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
Note
|
If ToR is already present in setup-data or already deployed, Tor info need not be added. By default ToR information switch
name is mapped in NFV bench.
|
|
Swiftstack
SwiftStack is only supported with Keystone v2. If you select Keystone v3, swiftstack will not be available for configuration.
|
Cluster End Point
|
IP address of PAC (proxy-account-container) endpoint.
|
Admin User
|
Admin user for swift to authenticate in keystone.
|
Admin Tenant
|
The service tenant corresponding to the Account-Container used by Swiftstack.
|
Reseller Prefix
|
Reseller_prefix as configured for Keystone Auth,AuthToken support in Swiftstack E.g KEY_
|
Admin Password
|
swiftstack_admin_password
|
Protocol drop-down list
|
http or https
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
LDAP with Keystone v3
|
Domain Name field
|
Enter the Domain name.
|
Object Class for Users field
|
Enter a string as input.
|
Object Class for Groups
|
Enter a string.
|
Domain Name Tree for Users
|
Enter a string.
|
Domain Name Tree for Groups field
|
Enter a string.
|
Suffix for Domain Name field
|
Enter a string.
|
URL field
|
Enter a URL with port number.
|
Domain Name for Bind User field
|
Enter a string.
|
Password field
|
Enter Password as string format.
|
User Filter
|
Enter filter name as string.
|
User ID Attribute
|
Enter a string.
|
User Name Attribute
|
Enter a string.
|
User Mail Attribute
|
Enter a string.
|
Group Name Attribute
|
Enter a string.
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
NFVI Monitoring
|
Followings are the field values for NFVI monitoring:
Master Admin IP field.
|
Enter Input as IP format.
|
Collector Management IP field
|
Enter Input as IP format.
|
Collector VM1 info |
|
Host Name field
|
Enter Host Name as a string.
|
CCUSER password field
|
Enter Password.
|
Password field
|
Enter password.
|
Admin IP field
|
Enter Input as IP format.
|
Management IP field
|
Enter Input as IP format.
|
|
|
Collector VM2 info |
|
Host Namefield
|
Enter a string.
|
CCUSER field
|
Enter Password.
|
Management IP field
|
Enter Input as IP format.
|
|
|
Dispatcher
|
|
Rabbit MQ Username Field
|
Enter a string.
|
|
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
VTS Parameter
|
Following are the fields to reconfigure for VTS parameters
VTC SSH Username field.
|
Enter the string.
|
VTC SSH Username field.
|
Enter the password.
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
VMTP
|
Check one of the check boxes to specify a VMTP network:
-
Provider Network
-
External Network
For the Provider Network complete the following:
Network Name field.
|
Enter the name for the external network.
|
IP Start field.
|
Enter the starting floating IPv4 address.
|
IP End field.
|
Enter the ending floating IPv4 address.
|
Gateway field
|
Enter the IPv4 address for the Gateway.
|
DNS Server field.
|
Enter the DNS server IPv4 address.
|
Segmentation ID field.
|
Enter the segmentation ID.
|
Subnet
|
Enter the Subnet for Provider Network.
|
|
|
For External Network fill in the following details:
Network Name field.
|
Enter the name for the external network.
|
Network IP Start field.
|
Enter the starting floating IPv4 address.
|
Network IP End field.
|
Enter the ending floating IPv4 address.
|
Network Gateway field
|
Enter the IPv4 address for the Gateway.
|
DNS Server field.
|
Enter the DNS server IPv4 address.
|
Subnet
|
Enter the Subnet for External Network.
|
-
Click Offline Validation .
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Networking
In Reconfigure optional services networking, you can reconfigure IP tables, or add http_proxy/https_proxy.
|
To reconfigure networking, update the relevant information:
IP Tables
|
Click Add(+) to add a table. Enter input as subnet format.
E.g. 12.1.0.1/2
|
http_proxy_server
|
Enter HTTP_PROXY_SERVER
E.g. <a.b.c.d:port>
|
https_proxy_server
|
Enter HTTP_PROXY_SERVER
E.g. <a.b.c.d:port>
|
Head-end replication
|
Add VTEP IP address and comma separated VNI IDs. Multiple entries are allowed. You can change VTEP IP for individual compute/control
servers.
Note
|
Whenever HER is removed from both vxlan-tenant and vxlan-tenant, all the vtep ips associated with the computes are removed.
|
|
Layer 3 BGP Adjacency
|
Applicable to control servers only when VXLAN is enabled in NETWORK OPTIONS.IPs are picked up from management subnet, but
not from IP pool. You can change the existing IP values if required.
|
-
Click Save.
-
Click Offline Validation.
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
APICINFO
Note
|
Reconfigure optional services only APIC hosts can be reconfigure.
|
|
To reconfigure APICINFO, follow the process:
-
Enter input for APIC hosts format. <ip1|host1>:[port] or eg.12.1.0.12
-
Click Save.
-
Click Offline Validation.
-
When Offline Validation is successful, click Reconfigure to commence the process.
Note
|
APIC hosts can be reconfigure minimum 1 host and max 3 but not 2 hosts.
|
|
Vim_admins
|
To reconfigure vim_admins, follow the process:
-
To add a new root user, Click + and add the Username and admin hash password (Starting with $6). At least, one Vim Admin must be configured, when Permit
root login is false.
-
To remove the existing user, Click -.
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
Cobbler
|
To reconfigure Cobbler, follow the process:
-
Generate the admin password hash by executing the below command:
python -c 'import crypt; print crypt.crypt
("<plaintext_strong_password>")'
on the management node.
-
Validate that the admin_password_hash starts with '$6'
-
Enter Admin Password Hash.
-
Click Offline Validation.
-
When Offline Validation is successful, click Reconfigure to commence the process.
|
ES Remote Backup
|
To reconfigure Elastic Search Remote Backup:
Service field displays NFS by default, if the remote NFS server is used.
-
Enter the Remote Host, which is IP of the NFS server.
-
Enter the Remote Path. . It is the path of the backup location in the remote server.
-
Click Offline Validation.
-
If Offline Validation is successful, click Reconfigure to commence the process.
|
CVIMMON
|
To reconfigure CVIMMON, enter the following details:
-
Enter the Low Frequency, such that it is higher than medium frequency. Minimum value is 1 minute. By default, it is set to 1 minute.
-
Enter the Medium Frequencysuch that it is more than high frequency. Minimum value is 30 seconds. By default, it is set to 30 seconds.
-
Enter the High Frequency such that the minimum value is 10 seconds. By default, it is set to 10 seconds.
-
Click Offline Validation.
-
If Offline Validation is successful, click Reconfigure to commence the process.
|
NETAPP_SUPPORT
|
To reconfigure NETAPP_SUPPORT, enter the following details:
-
Select the Server Port. It is the port of NetApp management or API server. Select 80 for HTTP and 443 for HTTPS.
-
Select the Transport Type of the NetApp management or API server. It can be HTTP or HTTPS.
-
Select the NetApp Cert Path. It is the root ca path for NetApp cluster, only if protocol is HTTPS.
-
Click Offline Validation.
-
If Offline Validation is successful, click Reconfigure to commence the process.
|