Release Notes for Cisco ONS 15454
Release 7.0.6Maintenance and Administration
Resolved Caveats for Release 7.0.6
Maintenance and Administration
New Features and Functionality
New Software Features and Functionality
DWDM Alarm Correlation Exceptions
TL1 Support for OCHCC RTRV-PATH-OCH Command
NE Defaults Support for ALS Mode
Obtaining Documentation and Submitting a Service Request
Release Notes for Cisco ONS 15454
Release 7.0.6
June 2008
Release notes address closed (maintenance) issues, caveats, and new features for the Cisco ONS 15454 ANSI MSTP. For detailed information regarding features, capabilities, hardware, and software introduced with this release, refer to the "Release 7.0.1" version of the Cisco ONS 15454 DWDM Reference Manual, Cisco ONS 15454 DWDM Troubleshooting Guide, Cisco ONS 15454 DWDM Procedure Guide, Cisco ONS SONET TL1 Command Guide, and Cisco ONS SONET TL1 Command Quick Reference Guide; and the "Release 7.0" version of the Cisco ONS 15454 Procedure Guide; Cisco ONS 15454 Reference Manual; and Cisco ONS 15454 Troubleshooting Guide. For the most current version of the Release Notes for Cisco ONS 15454 Release 7.0.1, visit the following URL:
http://www.cisco.com/en/US/products/hw/optical/ps2006/prod_release_notes_list.html
Cisco also provides Bug Toolkit, a web resource for tracking defects. To access Bug Toolkit, visit the following URL:
http://tools.cisco.com/Support/BugToolKit/action.do?hdnAction=searchBugs
Note ONS 15454 Release 7.0.6 contains resolution to an issue where OPT Preamplifier units with Firmware version 2.0.6, Hardware version 1.0.0, and Vendor ID 1025 are turning off during startup process. See CSCsh17399 for more details.
Contents
Resolved Caveats for Release 7.0.6
New Features and Functionality
Obtaining Documentation and Submitting a Service Request
Changes to the Release Notes
This section documents supplemental changes that have been added to the Release Notes for Cisco ONS 15454 Release 7.0.6 since the production of the Cisco ONS 15454 System Software CD for Release 7.0.1.
The following change has been made to the Release Notes for Release 7.0.6:
Caveat CSCsh17399 has been added to the list of Resolved Caveats. See CSCsh17399.
Caveat CSCsl22337 has been added to the Interoperability section. See CSCsl22337.
Caveats
Review the notes listed below before deploying the ONS 15454. Caveats with tracking numbers are known system limitations that are scheduled to be addressed in a subsequent release. Caveats without tracking numbers are provided to point out procedural or situational considerations when deploying the product.
Alarms
CSCsj26750
When the card type in CTC is changed from DS1_14 to DS1_E1_56 with DS1-14 physical card in the slot, the LED in DS1_14 card will show Act (Green) LED, instead of Fail (RED) LED. This issue will be resolved in a future release.
Hardware
CSCuk48503
Under specific conditions the 4x2.5G FEC Muxponder unit does not pass the Telcordia GR-253/G.825 Jitter generation mask test on 10G TX Trunk port. The 2.5 G TX Client jitter generation is always within mask and does not exhibit this issue. This occurs only when, in SONET mode, there is no FEC, no G.709, and client interfaces are looped back, with non-synchronous clocking, and the jitter testbox TX connected to Trunk RX port, while the jitter testbox RX is connected to the Trunk TX port. The jitter testbox TX clock recovers from RX with an additional 5 ppm offset added. This issue will not be resolved.
Maintenance and Administration
Caution VxWorks is intended for qualified Cisco personnel only. Customer use of VxWorks is not recommended, nor is it supported by Cisco's Technical Assistance Center. Inappropriate use of VxWorks commands can have a negative and service affecting impact on your network. Please consult the troubleshooting guide for your release and platform for appropriate troubleshooting procedures. To exit without logging in, enter a Control-D (hold down the Control and D keys at the same time) at the Username prompt. To exit after logging in, type "logout" at the VxWorks shell prompt.
CSCsd49163
In a Y cable protection group using TXP_MR_10E or TXT_MR_10DME cards the switch time when you remove a trunk fibre is sometimes longer than 50 ms. This issue will be resolved in a future release.
CSCsd21294
If you disconnect a subtended shelf from a multi-shelf node controller, the Communication failure is not correctly characterized by the LCD and Fan Tray LEDs of the multi-shelf node. You can use CTC or TL1 to get the status of the nodes correctly, however. This issue will be resolved in a future release.
CSCsd22880
The APC regulations when a channel is dropped from an AD4C are not correctly managed. Consider a channel dropped from the first CHAN-TX port of an AD4C card. In the CTC > Maintenance > DWDM tab the APC Last modification date is never changed; it remains N/A. In any case of span aging conditions, the object is always incorrectly referred to the fourth channel of the add/drop card, even if that channel is not active. This issue will be resolved in a future release.
CSCsd32197
Four channel Mux/Demux PM counters on CHAN ports (both TX and RX) fail to update after midnight in both CTM and TL1. This issue will be resolved in a future release.
CSCsd33369
ALS mode can be set to Auto Restart on a TXP_MR_10G trunk port via TL1 when the TXP_MR_10G card is configured for an Ethernet 10G LAN payload. This issue will be resolved in a future release.
CSCed23484
A user might remain in the logged-in state after rebooting the PC while logged into a node running CTC. The user login will time out once the "Idle User Timeout" limit is up. Alternatively, you can log in as a superuser and force the user off. This issue will not be resolved.
CSCef28522
When you inject errors on a splitter protection card in the node's working port, CVL and ESL are incremented for the working and protect far end ports. This issue will not be resolved.
CSCuk49106
The amplifier gain set point shown by CTC and the actual measured amplifier gain differ. The following steps illustrate this issue.
Step 1 Reduce the insertion loss of the span just before the amplifier.
Step 2 Execute the APC procedure.
The APC procedure does not check consistency between the gain set point and the real gain, but rather only verifies the amplifier total output power. As a workaround, manual setting can be performed to align these values, although the discrepancy does not impact the normal functioning of the amplifier. This issue will not be resolved.
CSCef29516
The ALS pulse recovery minimum value is 60 instead of 100. If this occurs, increase the value to 100. This issue will not be resolved.
CSCeb36749
In a Y-Cable configuration, if you remove the client standby RX fiber; a non-service affecting LOS is raised, as expected. However, if you then remove the trunk active RX fiber; a non-service affecting LOS-P is raised, but the previously non-service affecting LOS on the client port is now escalated to a service affecting alarm, in spite of no traffic having been affected. This issue will not be resolved.
Common Control Cards
CSCsd32113
The link status of the front Ethernet port is always reported as "up" by diagnostics. This is true whether or not there is an Ethernet connection to the front panel. This issue applies to TCC2P cards in secure mode. The link status LEDs on the front panel are not affected; they reflect the true state of the link. When examining diagnostics disregard the front-panel link status of TCC2P cards in secure mode. It is not known when or if this issue will be resolved.
DWDM Cards
CSCse07471
An MXP-MR-10DME card in GE mode might not recover from a synchronization loss fault condition. Near end and far end PM Ethernet counters exhibit truncated and errored packets in this case. This has been seen with a particular type of test set sending an invalid order set and truncated packet sequence while in LOS condition. Place the affected client port in OOS-IS state to recover. This issue will be resolved in a future release.
CSCsd47767
TXP_MR_10E transponders can take slightly longer than 50 ms to switch when you place the active trunk port OOS. This issue will be resolved in a future release.
CSCsd00491
On TXP_MR_10G transponders provisioned as terminal loopback on the trunk facility or on a client, the GCC channel is disabled. This issue will be resolved in Release 8.0.
CSCsd14754
After an LOS clears the on trunk port of a transponder, the alarms, ODUk-SD and OTUk-SD, are sometimes raised at the same time; the OTUk-SD should mask the ODUk-SD, but fails to do so. This issue will be resolved in Release 8.0.
CSCsd40399
On a TXP-MR-10E transponder provisioned as Line, Section or Transparent terminated, with OTN ON, FEC set to STD,ENH or disable, and a valid signal (OC192) on the client port, if OTUk-LOF is injected two alarms are raised: PTIM and OTU-LOF. The OTUk-LOF should mask the PTIM, but fails to do so. This issue will be resolved in Release 8.0.
CSCsd33382
A configured default of Ethernet 10G LAN for the TXP_MR_10G port assignment might be ignored. This can be seen when you provision the following default values for a TXP_MR_10G card:
•TXP-MR-10G.config.AlsMode = Auto Restart
•TXP-MR-10G.config.client.mrPortAssignment = 10G Ethernet LAN Phy
This provisioning is invalid as "Auto Restart" ALS (Automatic Laser Shutdown) mode is not valid for Ethernet payloads. However it is accepted by the NE. Now if you provision a TXP-MR-10G card, the configured default payload type of "Ethernet 10G LAN" is ignored, since it is inconsistent with the ALS value. It is not known if or when this issue will be resolved.
CSCeh22604
When an MXP_MR_2.5G card is in MIXED or ESCON mode, TCA and alarm optical thresholds of Tx power for laser bias are configurable for ESCON payload, though not supported. This issue will be resolved in the future release.
CSCei19148
When a port is placed in-service while the conditions necessary to squelch the port are present, as in when the trunk port on a DWDM card is OOS,DSBLD and a client port is placed in-service, the client will momentarily enable, emitting light, before squelching due to the trunk OOS,DSBLD condition. The pulse is approximately 500 ms. This issue will not be resolved.
CSCei87554
When using a 1GE payload over the TXP_MR_2.5G the IfInErrors counter does not report oversized, undersized, or CRC errored frames, but rather, reports frame coding only. This issue will not be resolved.
CSCsb47323
For MXP_MR_10DME-C and MXP_MR_10DME-L cards, an unexpected RFI condition might be raised along with an OTUk-BDI. When there is an LOS downstream, the node receives OTUk-BDI. Because of the placement of dual OTN and SONET wrappers, it can also receive an RFI. This issue will not be resolved.
CSCsb79548
A long traffic hit can occur when an active TCC2/TCC2P resets while an MXP_MR_10DME-C or MXP_MR_10DME-L card is rebooting.
This issue can be reproduced as follows:
Step 1 Set up two MXP_MR_10DME-C or MXP_MR_10DME-L cards, connected back-to-back in two different nodes, A and B.
Step 2 Ensure that Node A has two TCC2 cards; one is active, and the other is standby.
Step 3 Set up any kind of traffic between the two MXP_MR_10DME-C or MXP_MR_10DME-L cards.
Step 4 Soft reset the MXP_MR_10DME card in Node A, then soft reset the active TCC2/TCC2P.
OTUk/ODUk-SD, FEC Uncorrected word alarms are raised on the trunk port. Traffic goes down and does not recover until the MXP_MR_10DME card is able to come up. This issue will be resolved in a future release.
CSCsb94736
After a fault condition (trunk LOS or Y-cable switch) an MXP_MR_10DME card might fail to detect the login message and traffic might not start for some minutes (after multiple login trials). This can occur in an N-F configuration with MDS switch and MXP_MR_10DME distance extension on, where test equipment traffic is set to 2G Fibre channel (FC) full bandwidth occupancy and started. Stop traffic or keep bandwidth occupancy below 80% during the login phase to work around this issue. This issue will not be resolved.
CSCsb95918
All GFP related alarms are raised with their active severities on the standby card after a Y-Cable protection switch. When a DWDM card (with GFP support) in a Y-Cable protection group becomes standby as a result of a Y-Cable protection switch, the GFP alarms raised when the card was active retain their severities instead of assuming standby severities. The alarms can be seen in the alarm pane if not suppressed, or in the condition pane if suppressed. This issue will be resolved in a future release.
CSCsc36494
Manual Y cable switches with squelching turned off can cause a Fibre channel link with Brocade switches to go down.
This issue can be reproduced as follows:
Step 1 Set up MXP_MR_10DME cards so that they are Y cable protected. Squelching is provisioned to be off. Distance extension is turned on.
Step 2 The path between the working pair of Y cable protected cards, has no distance introduced. But the protect path has a delay of 800 km introduced.
Step 3 Start Fibre channel traffic with brocade switches.
Step 4 Perform user-initiated manual Y cable switches from CTC.
After a few switchovers, the FC link will go down. SIGLOSS and GFP-CSF alarms are seen on the CTC.
Cisco recommends you provision squelching to be on when interworking with brocade switches. If for some reason, squelching must be off with brocade switches, Cisco recommends you use a FORCE command to perform Y cable switches. It is not known when or if this issue will be resolved.
CSCsc55771
When two MXP_MR_10DME cards are interconnected through OC-192/STM-64 cross connects and traffic is up, if you hard reset one of the MXP_MR_10DME cards, the traffic might fail to recover. To recover traffic flow, place the client port in OOS,DSBLD state, delete the PPM then recreate it, and re-provision the port. This issue will be resolved in a future release.
CSCsc60472
CTC is not able to discover a TL1 OCHCC circuit provisioned over an ITU-T line card (ITU-T OC48/STM16 and ITU-T OC192/STM64). This issue can occur when, using the TL1 client interface, you create the OCHNC layer that will be used by the OCHCC circuit, then create the OCHCC connections that involve the ITU-T line cards. The result is an OCHNC and two OCHCC partial circuits, instead of an OCHNC and a single OCHCC complete circuit. This issue will not be resolved.
CSCsc62581
A T-TX-PWR-MIN TCA is raised and a wrong receive optical power value (of -40 dB) is displayed after a card is reset. The alert and incorrect Rx value both clear in the next 15 min. sample period. This issue will be resolved in a future release.
CSCsc54518
The OPT-BST amplifier card is in a LASER OFF state, even if input power is provided to all input ports. This issue only occurs with Release 7.0 and can be reproduced on a card with the amplifier turned on, in operating conditions (with lasers on) as follows.
Step 1 From the card-level Maintenance tab set ALS Mode to Manual Restart and click Apply.
Step 2 Set OSRI to ON and click Apply. The amplifier turns off.
Step 3 Set OSRI to OFF and click Apply. The amplifier stays turned off (this is expected, since in Manual Restart the lasers are turned back on by means of a Request Laser Restart command issued in CTC).
Step 4 Select the Request Laser Restart check box in the Maintenance tab and click Apply.
The amplifier goes into APR for 9 seconds (correct), but after this it turns off; it should go into LASER ON state (State 4 at module level). If this issue occurs, change the card from manual restart to auto restart, then toggle OSRI ON and OFF. This issue will be resolved in a future release.
CSCsc14290
LOW communication between two nodes equipped with TXP-MR-10E and AIC-I cards does not work with TXP-MR-10E cards in line termination mode, G.709 enabled, GCC present on the trunk port, and LOW circuits created between the transponders and AIC-I; Cisco recommends that you use EOW instead. This issue will be resolved in a future release.
CSCsc58941
Trunk ports of the TXPP_MR_2.5G and MXPP_MR_2.5G can be in facility and terminal loopback at the same time. This can occur if you provision terminal loopback on the protected trunk port after putting the trunk ports in facility loopback. You can clear this condition by removing loopback provisioning on the trunk ports. This issue will be resolved in a future release.
CSCeh94567
Setting a Terminal loopback on an MXP-2.5G-10G trunk port causes OTUK alarms.
This can occur under the following conditions.
1. Two MXP-2.5G-10G cards are connected via the trunk ports.
2. The client ports are connected to respective STM16 line cards.
3. SDCC is enabled on the client ports and the line cards' STM16 port.
4. A terminal loopback is set on the MXP-2.5G-10G trunk port.
This terminal loopback causes OTUK-LOF and OTUK-IA alarms to be reported on both MXP-2.5G-10G trunk ports. This issue will not be resolved.
CSCef15415
RMON TCAs are not raised on the TXPP_MR_2.5G client port after a hardware reset. To see this issue, provision two nodes with TXPP_MR_2.5G (TXP-1 and TXP-2) as follows.
Step 1 Connect the TXP-1 DWDM-A trunk to the TXP-2 DWDM-A trunk.
Step 2 Connect the TXP-1 DWDM-B trunk to the TXP-2 DWDM-B trunk.
Step 3 Create an external fiber loopback on the TXP-1 client.
Step 4 Connect the TXP-2 client to a traffic generator.
Step 5 Provision 1G FC payload on the TXP-1 and TXP-2.
Step 6 Ensure that traffic is running smoothly.
Step 7 Provision RMON thresholds using TL1 for all TXPP_MR_2.5G ports (client and trunks).
Step 8 Apply a hardware reset to the TXPP_MR_2.5G.
After the card reboots, only DWDM-A and DWDM-B (trunk) port RMON TCAs are raised in the CTC History pane. RMON TCAs for port 1 (client) are not raised. This issue will not be resolved.
CSCef15452
RMON TCAs are not raised when the RMON history is cleared on TXPP_MR_2.5G card. To see this issue, provision two nodes with TXPP_MR_2.5G (TXP-1 and TXP-2) as follows.
Step 1 Connect the TXP-1 DWDM-A trunk to the TXP-2 DWDM-A trunk.
Step 2 Connect the TXP-1 DWDM-B trunk to the TXP-2 DWDM-B trunk.
Step 3 Create an external fiber loopback on the TXP-1 client.
Step 4 Connect the TXP-2 client to a traffic generator.
Step 5 Provision 1G FC payload on the TXP-1 and TXP-2.
Step 6 Ensure that traffic is running smoothly.
Step 7 Provision RMON thresholds using TL1 for all TXPP_MR_2.5G ports (client and trunks).
Step 8 While the traffic is running reset the RMON history by clicking the Clear button in the CTC Payload PM pane.
RMON TCAs are not raised for any port. This issue will not be resolved.
CSCef13304
Incorrect ALS initiation causes a traffic outage on an FC payload. This issue can be seen by performing the following steps.
Step 1 Set up two nodes with TXPP_MR_2.5G (call these nodes TXP-1 and TXP-2).
Step 2 Connect the TXP-1 DWDM-A trunk to the TXP-2 DWDM-A trunk.
Step 3 Connect the TXP-1 DWDM-B trunk to the TXP-2 DWDM-B trunk.
Step 4 Provision the TXP-1 client with an external fiber loopback.
Step 5 Connect the TXP-2 client to a traffic generator.
Step 6 Ensure that TXP-1 and TXP-2 have 1G FC payload provisioned.
Step 7 Enable ALS on TXP-1 trunk port and set it to "Manual Restart."
Step 8 When traffic is running, remove the receive and transmit fibers on TXP1 port 1 (client). Traffic goes down and shutdown on TXP-1 port 2 (trunk) displays "No."
Step 9 Reconnect the fibers for TXP-1 port 1 (client).
ALS is now initiated on TXP-1 port 2 (trunk) and the laser shuts down. Traffic never comes back.
Note This issue is restricted to the TXPP_MR_2.5G card.
To recover from this situation, perform a manual restart or disable the ALS in this configuration. This issue will not be resolved.
CSCec22885
AS-MT is not enabled in Port 3 when a loopback is applied. To see this issue, on the TXPP card, make the following 3 changes before clicking Apply:
Step 1 Change Port 2 to OOS-MT from IS.
Step 2 Change Port 3 to OOS-MT from IS.
Step 3 Change Port 2 to facility or terminal loopback.
Now, when you click Apply, CTC issues the error message: "Error applying changes to row2 peer trunk port must not be IS." Port 3 is still IS and the loopback changes are not applied. You must place Port 3 in the OOS-MT state, apply the changes, and then change the loopback to recover.
This error occurs only when all three of the above changes are attempted at the same time.
To avoid this issue, first change both the trunk ports to OOS-MT, click Apply, and then place port 2 in loopback and click Apply again. This issue will not be resolved.
CSCed76821
With Y-cable provisioned for MXP-MR-2.5G cards, if you remove the client receive fiber on one side, the far end takes greater than 100 ms to switch away from the affected card. This issue will not be resolved.
CSCef44939
Under certain conditions you may be unable to provision an Express Order Wire (EOW) circuit using an MXP_2.5G_10G or TXP_MR_10G card trunk port. This can occurs as follows.
Step 1 Provision an MXP_2.5G_10G or TXP_MR_10G card within a node.
Step 2 Disable OTN.
Step 3 Provision DCC on both client and trunk ports.
Step 4 Go to the Network view Provisioning > Overhead Circuits tab.
During the EOW circuit provisioning only the MXP/TXP client ports are listed for the selection. This issue will not be resolved.
CSCuk51185
After a soft reset of an OSCM or OSC-CSM card, a CONTBUS-IO alarm is raised. This issue will not be resolved.
CSCuk50144
Neither E1 nor E2 circuits are available for EOW circuits on TXP_MR_2.5 TXT in Section and Line Termination mode. This issue will not be resolved.
CSCec40684
After a database restore TXPP trunk ports might report SF, resulting in a traffic outage. The SF occurs when you restore the database and then put the port OOS for DWDM cards; then the operating mode in the database is different from the current operating mode. To avoid this issue, either put the DWDM port OOS before restore the database, or, after restoring the database, reset the DWDM cards. This issue will not be resolved.
CSCec51270
Far end traffic does not switch in line termination mode with .G709 off. This can occur with non-revertive Y-cable, and DCC enabled, using TXP-MR-2.5G cards, under certain specific conditions. To avoid this issue, turn on .G709 when in line mode. This issue will not be resolved.
CSCuk42668
TXP-MR-2.5G F1-UDC may not be passed through in a line-terminated configuration with OTN off. This can occur with clean, OC-3/STM-1, line-terminated traffic, with OTN disabled, when you create a D1-D3 tunnel, a D4-D12 tunnel, and an F1-UDC from client to client. This issue will not be resolved.
CSCuk42752
If you go to the Overhead Circuits Tab in network view and select any User Data, F1 or User Data D4-D12 circuit type, no nXP cards are available for selection in the Endpoints. However, user Data type circuits can still be made end-to-end (where "end-to-end" refers to external cards, such as AIC to AIC) if the nXP cards are put in Transparent mode. This issue will not be resolved.
CSCeb49422
With TXPP cards, a traffic loss up to six seconds can occur during a DWDM protection switch. This behavior may be exhibited during protection switches by certain third-party fiber channel switches due to loss of buffer credits resulting in a reconvergence of the fiber channel link. This issue will not be resolved.
CSCeb53044
The 2G Fiber Channel (FC) payload data type in the TXP_MR_2.5G and TXPP_MR_2.5G cards do not support any 8B/10B Payload PM monitoring. This is as designed.
CSCea78210
The TXP_MR_2.5G and TXPP_MR_2.5G cards do not support TX Optical power performance monitoring on the trunk port. This is as designed.
CSCeb32065
Once engaged, ALR will not restart on the trunk lines of a TXP or TXPP card. This occurs whenever ALR engages on the trunk lines of a TXP or TXPP card and the recover pulse width is provisioned to less than 40 seconds. This is a function of the trunk laser turn-on time, and the limiting recovery pulse width will vary by card. To avoid this issue, provision the pulse width to 40 seconds or more. This issue will not be resolved.
CSCuk42588
With ALS mode configured as "Auto Restart" or "Manual Restart," it is possible the ALS Pulse Duration Recovery time can be set to values out of ITU-T recommendation G.664. You can use values out of the range defined in ITU-T recommendation G.664 only in order to interoperate with equipment that lasers cannot turn on or off within the required pulse time. To stay within the specification, you can set this value to 2 seconds and up to 2.25 seconds.
CSCeb12609
For the TXPP, attenuating Port 2 Rx signal, SD, and SF alarms are not declared before LOS-P is raised. This is due to the intrinsic design of the optical interface, which allows required BER performances with dispersion and OSNR penalties.
This can occur when Port 2 is in back to back or has low dispersions and high OSNR.
CSCea68773
The ACTV/STBY LED shows AMBER when a 2.5G transponder is first connected. The DWDM cards introduced a new design: When all the ports are OOS on a card, the card is considered to be in standby mode.
Interoperability
CSCsl22337
When a DWDM ring or network has to be managed through a Telcordia operations support system (OSS), every node in the network must be set up as multi-shelf. OLA sites and nodes with one shelf must be set up as "multi-shelf stand-alone" to avoid the use of LAN switches.
Resolved Caveats for Release 7.0.6
This section documents caveats resolved in Releases 7.0, 7.0.1, and 7.06.
Maintenance and Administration
CSCsh17399
Sometimes, OPT Preamplifier units with Firmware version 2.0.6, Hardware version 1.0.0, and Vendor ID 1025 turn off during startup process.
The issue occurs because the settling time of the trans-impedance of the PRE photodiode is not enough. This sometimes causes the amplifier turn off during startup process.
This issue has been resolved in Release 7.0.6.
CSCsd55460
When upgrading a network to Release 6.0.1, 6.1, or 7.0, where LOS-P exists on a pass-through port of a WSS for a ROADM node, if you change the circuit state to OOS,DSBLD and then again to IS-AINS, the circuit fails to go up. There are two possible work-arounds:
1. Change the calibration value on the pass-through port of the WSS.
2. When the circuit is in OOS state, relaunch ANS.
This issue is resolved in Releases 6.2 and 7.0.1.
CSCsd31753
After card pre-provisioning, if you launch an ANS default patchcord using CTC or TL1, the TCC resets and internal patchcords are not created. This can occur in an OADM or Flexible terminal MSTP node configured with any possible combination of AD-xC card, but containing wavelength 1560.61 (that is AD-1C-60.6, AD-2C-59.7 and AD-4C-58.1). Any Fiber stage configuration will display this issue. This issue is resolved in Release 7.0.1.
CSCsc61572
Traffic incurs a hit when a Y-cable protection group is created with an IS working facility and OOS,DSBLD protect facility. If a Y-cable protection group is created, and traffic is flowing cleanly over the working facility, and the protect facility is OOS,DSBLD, the working facility will momentarily shutdown and then restart. This behavior is generally not seen when a deleted protection group is recreated, provided that the Y-cable cards and the shelf controller have not been reset since the protection group was deleted. Therefore, to reproduce this issue it is necessary to soft reset the Y-cable cards and the shelf controller before creating the protection group. This issue is resolved in Release 7.0.1.
CSCsd32106
Traffic is lost briefly when a Y-cable group is created and the working facility is preprovisioned. The traffic hit occurs when traffic is flowing over the planned protect path, and the planned working path is only preprovisioned. When the Y-cable group is created, the group selects the working path, interrupting traffic. Within one second the group selects the protect path, restoring traffic. This issue is resolved in Release 7.0.1.
CSCsd18450
A node with TCC2P cards in "Data Comm Secure Mode" and the SOCKS Proxy in ENE mode cannot be reached via its LAN connection. This occurs when the TCC2P cards are placed in Data Comm Secure Mode and the SOCKS Proxy is configured for ENE operation. Under most IP address configurations, the node will become unreachable by its backplane connection. Also, if the front panel Ethernet and the backplane Ethernet are on the same LAN, the node might be unreachable via either interface. When both interfaces are on the same LAN, the ARP cache can become corrupted and will contain incorrect data until the ARP entries expire. To work around this issue you can configure the node as a SOCKS Proxy GNE. This is always permissible, even if the node is not connected to the DCN. Also, avoid making an Ethernet connection to the backplane Ethernet of an ENE in secure mode. This issue is resolved in Release 7.0.1.
DWDM Cards
CSCsd33492
Rarely, pre-amplifiers and booster amplifiers (15454-OPT-BST, 15454-OPT-PRE) might raise an equipment failure alarm for an internal communication issue, even though operating conditions remain unaffected. This alarm will disabled APC control in the network and prevent circuit creation. If this occurs, perform a non-traffic affecting reset using the CTC craft terminal on the line card to clear the alarm. This issue occurs only when the line cards have a component mounted with component vendor ID 1025. This issue is resolved in Releases 6.2 and 7.0.1.
CSCsc56015
Extracting an MSTP card and inserting a different type of card in the same slot will result in an MEA alarm and APC DISABLE condition being raised. The APC DISABLE condition will not clear even if you insert the correct card. The workaround is to send a software reset to the active TCC. This issue is resolved in Release 7.0.1.
CSCei37691
The trunk port service state for the TXPP and TXP cards does not transition to OOS-AU,FLT in the presence of an LOS-P alarm. This can occur when the payload signal for LOS-P is missing for the particular port type. This issue is resolved in Release 7.0.
CSCuk57046
An unexpected Mismatch Equipment Attributes (MEA) transient alarm can occur on rapidly inserting and removing a PPM. This issue can occur with a TXP_MR_10E-L for which you preprovision an OC-192 PPM. The transient alarm is raised on the PPM. This issue is resolved in Release 7.0.
Electrical IO Cards
CSCsd59042
When upgrading the software from Release 6.x.x to Release 7.x.x, the DS3 and EC1-12 cards fail to load if the node name begins with the letters FL. Changing the node name resolves this issue.
TL1
CSCsc62784
The Calibration Tilt is not properly changed using the TL1 interface. The reference tilt is changed instead. This issue can be seen when you try to change the CALTILT parameter on amplifier cards using the ED-OTS command. To avoid this issue, use CTC. This issue is resolved in Release 7.0.1.
New Features and Functionality
This section highlights new features and functionality for Release 7.0.1. For detailed documentation of each of these features, consult the user documentation.
New Software Features and Functionality
Secure Mode on Multishelf
In Release 7.0.1 both single-shelf and multishelf configurations support the use of secure mode and locked secure mode. The procedures for using secure mode in multishelf configurations do not differ from the procedures used in single shelf configurations. The default setting for secure mode is "off." Consult the user documentation prior to using secure mode in any configuration.
NLAC Trunk TCA Suppression
With Release 7.0.1 OTN Based Network Level alarm correlation adds the ability to automatically demote Threshold Crossing Alerts (TCAs), throttling spontaneous multiple notifications of management interfaces when a server alarm is outstanding on the facility or port.
Threshold defaults are defined for near end and/or far end and at 15-minute or one-day intervals. When LOS-P, LOS, or LOF alarms occur on TXP or MXP cards, different TCAs are suppressed depending on how the trunk is configured (G.709, SONET, or SDH). See the user documentation for a table of TCAs for each type of trunk framing and alarm.
TCA suppression does not extend to optical thresholds such as OPR (optical power received). Optical threshold TCAs can effectively be suppressed by setting their thresholds to the maximum value. TCA suppression also does not extend to client ports; it only applies to TXP and MXP trunk ports when they are configured as G.709, SONET, or SDH. TCA suppression does not extend to 10GE payloads.
Because they are preempted from being raised, suppressed TCAs do not show up as Not Reported (NR) conditions in the CTC Conditions tab and they cannot be retrieved with the RTRV-COND TL1 command.
DWDM Alarm Correlation Exceptions
In multishelf correlated alarms the Payload Missing Indication (PMI) condition is raised at the far end to correlate optical multiplex section (OMS) and optical transmission section (OTS) communication failures. A single PMI condition is sent when every channel on the aggregated port is lost; that is, when all pass-through channels are lost and there are no active add channels. If there are add channels on the node, the Forward Defect Indication (FDI) condition is sent downstream to indicate that a given channel has been lost upstream.
In Release 7.0.1, two exceptions apply to DWDM alarm correlation as previously described. In ROADM configurations, if any drop traffic is lost on a WSS COM-TX port, the event does not raise a PMI condition for the COM-TX port; instead, each errored channel associated with the CHAN-(i)-TX port raises an FDI condition. Similarly, if a WSS EXP-RX port loses any pass-through traffic, an FDI condition is raised against each errored channel associated with the PT-(i) port and no PMI is raised on the EXP-RX port.
TL1 Support for OCHCC RTRV-PATH-OCH Command
Release 7.0.1 adds a TL1 command, RTRV-PATH-OCH, to retrieve all OCH terminations inside a specified node. The TL1 RTRV-PATH-OCH command lists in output all OCH Terminations belonging to a single optical connection. The command accepts in input either the wavelength or any OCH Termination. The output lists all the OCH Terminations belonging to the circuit in the TID. For a full description of the command and its application consult the Cisco ONS SONET TL1 Command Guide for Release 7.0.1.
OCH Optical Link Support
Release 7.0.1 add support for optical provisionable patchcords, or virtual links between OCH filter and trunk ports. For the specific situations in which a patchcord is necessary, refer to the "Management Network Connectivity" chapter in the Cisco ONS 15454 DWDM Reference Manual.
CTC Support for OCH Optical Links
If a provisionable patchcord is manually created using CTC, it automatically tunes the TXP or MXP trunk as an OCH filter—provided that the TXP or MXP is set to autoprovisioning at the first tunable wavelength.
TL1 Support for OCH Optical Links
In Release 7.0.1 TL1 the ENT-LNK command is enhanced to support the creation of optical links between optical channel ports of the same wavelength. When the enhanced command is used to create an optical link between two optical channel ports, where the first port belongs to an OCH filter and the second port is an OCH trunk, the second port can be automatically tuned to the same wavelength as that of the OCH filter, if it has not been set yet. The ENT-LNK command From and To Band AIDs are replaced with new Channel AIDs in Release 7.0.1. Channel AIDs access the optical channels (OCH) layer of an optical networking unit. For specific channel values and their descriptions consult the Cisco ONS SONET TL1 Command Guide for Release 7.0.1.
NE Defaults Support for ALS Mode
Release 7.0.1 adds the ability to disable the ALS/APR through an NE default. The Defaults editor and defaults file add an ALS mode entry that can be set to Disabled or Auto Restart for the following cards:
•OPT-BST
•OPT-BST-L
•OSCM
•OSC-CSM
The default value for ALS mode on the OPT-BST, OPT-BST-L, OSCM, and OSC-CSM is Auto Restart (enabled). For information on how ALS card settings achieve network level optical safety consult the "Network Optical Safety--Automatic Laser Shutdown" section in the Cisco ONS 15454 DWDM Reference Manual.
Related Documentation
Release-Specific Documents
•Release Notes for the Cisco ONS 15454, Release 7.0
•Release Notes for the Cisco ONS 15454 SDH, Release 7.0.1
•Cisco ONS 15454 Software Upgrade Guide, Release 7.0.1
Platform-Specific Documents
•Cisco ONS 15454 DWDM Procedure Guide
Provides installation, turn up, test, and maintenance procedures•Cisco ONS 15454 DWDM Reference Manual
Provides technical reference information for DWDM cards, nodes, and networks•Cisco ONS 15454 DWDM Troubleshooting Guide
Provides a list of DWDM alarms and troubleshooting procedures, general troubleshooting information, and hardware replacement procedures•Cisco ONS SONET TL1 Command Guide
Provides a comprehensive list of TL1 commands•Cisco ONS SONET TL1 Command Quick Reference Guide
Provides a quick reference to TL1 commandsObtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.
© 2007 Cisco Systems, Inc. All rights reserved.