Contents
This document provides compatibility information and installation procedures for Gigabit Interface Converter (GBIC), Small Form-factor Pluggable (SFP), Enhanced Small-Form-factor Pluggable (SFP+), and10 Gbps Small Form-factor Pluggable (XFP), 120 Gbps 12x Small Form-factor Pluggable (CXP), and C Form-factor Pluggable (CFP) optical modules used with the Cisco ONS 15454 M2, Cisco ONS 15454 M6, ONS 15454, Cisco ONS 15454 SDH, Cisco ONS 15310-CL, Cisco ONS 15310-MA, Cisco ONS 15310-MA SDH, Cisco ONS 15600, and Cisco ONS 15600 SDH Cisco Carrier Packet Transport (CPT)—CPT 600, CPT 200, and CPT 50 nodes. This document also contains removal instructions, cabling, and technical specifications. Use this document in conjunction with platform-specific Cisco user documentation when working with GBICs, SFP, SFP+, XFP, CXP, CFP, or CPAKSFP, SFP+, or XFP modules or any other system components.
The GBICs, SFP, SFP+, XFP, CXP, CFP, or CPAKSFP, SFP+, and XFP modules are referred to as pluggable port modules (PPMs) in Cisco Transport Controller (CTC).
The following table lists new and changed content made to this document since it was first published.
Date |
Change Summary |
---|---|
August 2011 |
Updated the specifications for ONS-SC-OSC-ULH SFP in the section "Single-Mode Fiber SFP Port Cabling Specifications". |
September 2011 |
Updated the specifications for ONS-SC-OSC-ULH SFP in the section "Single-Mode Fiber SFP Port Cabling Specifications". |
November 2011 |
|
February 2012 |
Added a footnote for the ONS-XC-10G-C XFP in the section "Compatibility by Card-Cisco ONS 15454 M2, Cisco ONS 15454 M6, Cisco ONS 15454, and Cisco ONS 15454 SDH". |
April 2012 |
Updated the section "DLP-G723 Install PPM on a Line Card". |
July 2012 |
|
September 2012 |
|
March 2013 |
Release 9.6.0.3 updates
|
June 2013 |
|
July 2013 |
Release 9.8 updates |
November 2013 |
Release 10.0 updates |
November 2014 |
Release 10.1 updates |
March 2015 |
Release 10.3 updates |
June 2015 |
Release 9.7.0.5 updates |
Date |
Change Summary |
---|---|
June 2015 |
|
February 2015 |
|
March 2014 |
Added information about the SFP pluggables, ONS-SC-155-TSOP and ONS-SC-622-TSOP. |
August 2012 |
|
July 2012 |
PPM information related to Cisco CPT 200, Cisco CPT 600, and Cisco CPT 50 units are removed from the Installing the GBIC, SFP, SFP+, XFP, CXP, and CFP Optical Modules in Cisco ONS Platforms document and published this document. |
April 2012 |
Updated the section "DLP-G723 Install PPM on a Line Card". |
The GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP optics modules are hot-swappable I/O devices that plug into a line card port to link the port with the fiber optic network. For all cards, the type of GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP modules that is plugged into the card is displayed in Cisco Transport Controller (CTC) and in Transaction Language 1 (TL1).
Note |
|
The following table lists PPMs with their categories, card supported, descriptions, TAN number and temperature range.
Compatible Pluggable (Cisco Product ID) |
Description |
Card Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-SE-GE-BXU= |
SFP – 1000BASE-BX U – GE Bidirectional Upstream– Ext Temp |
CPT 50 |
- |
0 to +85 |
ONS-SE-GE-BXD= |
SFP – 1000BASE BX D – GE Bidirectional Downstream Ext Temp |
CPT 50 |
- |
0 to +85 |
ONS-SE-100-BX10U= |
SFP – 10/100 BX-U, EXT |
CPT 50 |
10-2353-01 |
–10 to +85 |
ONS-SE-100-BX10D= |
SFP – 10/100 BX-D, EXT |
CPT 50 |
10-2352-01 |
–10 to +85 |
ONS-SI-100-FX= |
SFP – 100 Mbps Short Reach – 1310 nm – MM – LC, I‑TEMP |
CPT 50 |
10-2350-01 |
–40 to +85 |
ONS-SI-100-LX10= |
SFP – 100 Mbps Long Reach – 1310 nm – SM – LC, I‑TEMP |
CPT 50 |
10-2294-01 |
–40 to +85 |
ONS-SI-GE-LX= |
SFP – 1000BASE-LX Gigabit Ethernet, 1310 nm, SM, I‑TEMP |
CPT 50 |
10-2300-01 |
–40 to +85 |
ONS-SI-GE-SX= |
SFP – 1000BASE-SX Gigabit Ethernet, 850 nm, MM, I‑TEMP |
CPT 50 |
10-2295-01 |
–40 to +85 |
ONS-SI-GE-ZX= |
SFP – 1000BASE-ZX Gigabit Ethernet, 1550 nm, SM, I‑Temp |
CPT 50 |
10-2296-01 |
–40 to +85 |
ONS-SI-GE-EX= |
SFP - 1000Base EX - I-Temp |
CPT 50 |
10-2734-01 |
–40 to +85 |
Compatible Pluggable (Cisco Product ID) |
Description |
Card Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-SC-2G-28.7= |
OC-48/STM-16, SFP, 1528.77, 100 GHz, LC |
CPT 50 |
10-2307-02 |
0 to +70 |
ONS-SC-2G-30.3=through ONS-SC-2G-60.6= |
OC-48/STM-16, SFP, 1530.33, 100 GHz, LC through OC-48/STM-16, SFP, 1560.61, 100 GHz, LC |
CPT 50 |
10-2155-02 through 10-2184-02 |
0 to +70 |
ONS-SC-2G-37.4= |
SFP – OC-48/STM16, 1537.40nm, 100 GHz, SM, LC |
CPT 50 |
10-2668-01 |
0 to +70 |
ONS-SC-2G-45.3= |
SFP – OC-48/STM16, 1545.32nm, 100 GHz, SM, LC |
CPT 50 |
10-2670-01 |
0 to +70 |
ONS-SC-2G-53.3= |
SFP – OC-48/STM16, 1553.33nm, 100 GHz, SM, LC |
CPT 50 |
10-2669-01 |
0 to +70 |
ONS-SC-155-TSOP= |
SFP - STM1, OC3 clear channel over GE, I Temp |
CPT 50 |
10-2949-01 |
-40 to +85 |
ONS-SC-622-TSOP= |
SFP - STM4, OC12 clear channel over GE, I Temp |
CPT 50 |
10-2950-01 |
-40 to +85 |
Compatible Pluggable (Cisco Product ID) |
Description |
Card Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-SC+-10G-EP-30.3= through ONS-SC+-10G-EP-61.4= |
10 GB DWDM,SFP+ 1530.33,10G/bs through 1561.83,10G/bs, SFP+ |
Fabric, Line and CPT 50 |
|
0 to +70 |
Compatible Pluggable (Cisco Product ID) |
Description |
Card Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-XC-10G-C= |
10G Multirate Full C Band Tunable DWDM XFP, 50 GHz, LC |
Fabric |
10-2480-01 |
0 to +70 |
ONS-SC+-10G-30.3= through ONS-SC+-10G-61.4= |
10G MR, SFP+ 1530.33, 100 GHz, LC through 10G MR, SFP+ 1561.43, 100 GHz, LC |
Fabric |
10-2690-01 through 10-2721-01 |
0 to +70 |
Compatible Pluggable (Cisco Product ID) |
Description |
Card Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-SE-ZE-EL= |
SFP – 10/100/1000 Ethernet BASE-T Multirate Copper RJ-45 |
CPT 50 |
10-2351-01 |
-10 to +85 |
ONS-SE-100-LX10= |
SFP - 100 Mbps Long Reach - 1310 nm - SM - LC, EXT-TEMP |
CPT 50 |
10-2213-01 |
-10 to +85 |
ONS-SC-E1-T1-CES= |
SFP - E1/DS1 PDH over FE Pseudowire (w / sync-E) - C-Temp |
CPT 50 |
30-1462-01 |
-40 to +75 |
ONS-SC-E3-T3-CES= |
SFP - E1/DS1 PDH over FE Pseudowire (w / sync-E) - C-Temp |
CPT 50 |
30-1463-01 |
-40 to +75 |
ONS-SC-GE-BXD= |
SFP-1000Base BX D- GE Bidirectional Upstream C Temp |
CPT 50 |
10-2731-01 |
0 to +70 |
ONS-SC-GE-BXU= |
SFP-1000Base BX D- GE Bidirectional Downstream C Temp |
CPT 50 |
10-2732-01 |
0 to +70 |
Compatible Pluggable (Cisco Product ID) |
Description |
Card Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-SE-2G-1470= through ONS-SE-2G-1610= |
SFP – OC-48/STM-16/GE, CWDM, 1470 nm Ext Temp through SFP – OC-48/STM-16/GE, CWDM, 1610 nm Ext Temp |
CPT 50 |
10-2461-01 through 10-2468-01 |
0 to +85 |
Compatible Pluggable (Cisco Product ID) |
Description |
Cards Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-XC-10G-1470= through ONS-XC-10G-1610= |
OC192/10GE/OTU2, CWDM, 1470mn, XFP C-Temp, 40km range through OC192/10GE/OTU2, CWDM, 1610nm, XFP C-Temp, 40km range |
CPT 50 |
10-2548-01 through 10-2557-011 |
0 to +70 |
Compatible Pluggable (Cisco Product ID) |
Description |
Cards Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-SC+-10G-LR= |
SFP+ LR – Commercial Temp |
Fabric and Line |
10-2618-01 |
0 to +70 |
ONS-SC+-10G-SR= |
SFP+ SR – Commercial Temp |
Fabric and Line |
10-2620-01 |
0 to +70 |
ONS-SC+-10G-ER= |
SFP+ ER – Commercial Temp |
Fabric and Line |
10-2619-01 |
0 to +70 |
ONS-SC+-10G-ZR= |
SFP+ ZR – Commercial Temp |
Fabric and Line |
10-2730-01 |
0 to +70 |
ONS-SC+-10G-LRM= |
SFP+ LRM - Commercial Temp |
Fabric, Line and CPT 50 |
10-2689-01 |
0 to +70 |
ONS-SE+-10G-LR= (Extended temp LR, SFP+) |
SFP+ LR - EXT Temp |
Fabric, Line and CPT 50 |
10-2733-01 |
–5 to +85 |
Compatible Pluggable (Cisco Product ID) |
Description |
Cards Supported |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-XC-10G-I2= |
XFP – OC-192/STM-64/10GE – 1550 IR2 – SM LC |
Fabric |
10-2193-02 |
0 to +70 |
ONS-XC-10G-L2= |
XFP – OC-192/STM-64 – 1550 LR2 – SM LC |
Fabric |
10-2194-02 |
0 to +70 |
ONS-XC-10G-S1= |
XFP – OC-192/STM-64/10GE – 1310 SR – SM LC |
Fabric |
10-2012-03 |
0 to +70 |
ONS-XC-10G-SR-MM= |
XFP – Ultra Short Reach MM –10GE BASE SR |
Fabric |
10-2420-01 |
0 to +70 |
ONS-XC-10G-EP30.3= through ONS-XC-10G-EP61.4= |
10G MR, XFP,Edge Performance 1530.33, 100 GHz, LC through 10G MR, XFP,Edge Performance 1561.43, 100 GHz, LC |
Fabric |
10-2577-01 through 10-2591-01 |
0 to +70 |
Compatible Pluggable (Cisco Product ID) |
Description |
Card |
Cisco Top Assembly Number (TAN) |
Temperature Range (°C) |
---|---|---|---|---|
ONS-SC+-10G-CU1= |
10GBASE-CU SFP+ Cable 1 Meter |
Fabric and Line |
37-1188-01 |
0 to +70 |
ONS-SC+-10G-CU3= |
10GBASE-CU SFP+ Cable 3 Meter |
Fabric and Line |
37-1197-01 |
0 to +70 |
ONS-SC+-10G-CU5= |
10GBASE-CU SFP+ Cable 5 Meter |
Fabric and Line |
37-1198-01 |
0 to +70 |
ONS-SC+-10G-CU7= |
10GBASE-CU SFP+ Cable 7 Meter |
Fabric and Line |
37-1196-01 |
0 to +70 |
The SFP modules are integrated fiber optic transceivers that provide high speed serial links from a port or slot to the network. The SFP+ transceiver is an enhancement over the SFP optics developed for 1 Gbps Ethernet and 1 Gbps, 2 Gbps, and 4 Gbps Fibre Channel. The SFP+ modules extend the data rate up to 11.10 Gbps. SFP+ modules also provide 2-wire serial, I2C interface. The I2C interface is used for serial ID, digital diagnostics, and module control functions.
Various latching mechanisms can be utilized on the SFP and SFP+ modules. There is no correlation between the type of latch and the model type (such as SX or LX/LH) or technology type (such as Gigabit Ethernet). See the label on the SFP and SFP+ modules for technology type and model. One type of latch available is a mylar tab as shown in Figure 4Figure 1, a second type of latch is an actuator/button (Figure 5Figure 2), and the third type of latch is a bail clasp (Figure 6Figure 3 and Figure 7Figure 4).
SFP and SFP+ module dimensions are:
SFP and SFP+ module temperature ranges are:
COM—Commercial operating temperature range between 23 degrees Fahrenheit to 158 degrees Fahrenheit (–5 degrees Celsius to 70 degrees Celsius)
EXT—Extended operating temperature range between 23 degrees Fahrenheit it to 185 degrees Fahrenheit (–5 degrees Celsius to 85 degrees Celsius)
IND—Industrial operating temperature range between –40 degrees Fahrenheit to 185 degrees Fahrenheit (–40 degrees Celsius to 85 degrees Celsius)
Caution |
Do not add labels or markings to the SFP and SFP+ modules. |
The following table lists specifications for available SFPs.
Important notes for the following table:
The ONS-SC-2G-28.7, ONS-SC-2G-33.4, ONS-SC-2G-41.3, ONS-SC-2G-49.3, and ONS-SC-2G-57.3 SFPs are supported in Cisco ONS Software Release 8.5 and later releases.
The ONS-SC-2G-28.7= through ONS-SC-2G-60.6= SFPs on the TNC and TNCE cards support only GE payload.
The LED based SFPs ( ONS-SI-100-FX) do not support the optical power transmitted (OPT) and laser bias current (LBC) optical parameters.
For ONS-SE-4G-SM SFP, specified Optical Modulation Amplitude (OMA) at 4.25 Gbps is equal to an average power of -7.3 dBm at an ER of 9 dB (transmitter output power) and specified OMA at 4.25 Gbps is equal to an average power of -17.3 dBm at an ER of 9 dB (receiver power input).
For ONS-SE-2G-30.3 through ONS-SE-2G-60.6 SFPs, the power limited performance at bit error rate (BER) = 10e-12 with SONET framed PRBS23, optical signal-to-noise ratio (OSNR) of 21 dB, 0.1 nm bandwidth (BW) and power limited performance at BER = 10e-12 with SONET framed PRBS23, OSNR of 16 dB, 0.1 nm BW.
SFP |
Interface |
Transmitter Output Power Min/Max (dBm) |
Receiver Input Power Min/Max (dBm) |
---|---|---|---|
ONS-SC-2G-28.7= through ONS-SC-2G-60.6= |
OC-48, STM-16, GE |
0 to +4 |
–28 to –9 |
ONS-SC-4G-30.3= through ONS-SC-4G-61.4= |
4G FC |
0 to +4 |
–28 to –9 |
ONS-SE-100-FX= |
100 Mbps long reach - 1310 nm - SM - LC, EXT-TEMP |
–20 to –14 |
–31 to –14 |
ONS-SE-100-LX10= |
100 Mbps long reach - 1310 nm - MM - LC, EXT-TEMP |
–15 to –8 |
–28 to –8 |
ONS-SE-155-1470= through ONS-SE-155-1610= |
OC-3, STM-1 |
0 to +5 |
–34 to –7 |
ONS-SE-4G-MM= |
4G FC/Ficon |
–9 to –2.5 |
–15 –18 to –3 |
ONS-SE-4G-SM= |
4G FC/Ficon |
290 microwatts OMA |
29 microwatts OMA |
ONS-SE-622-1470= through ONS-SE-622-1610= |
OC-12, STM-4 |
0 to +5 |
–28 to –7 |
ONS-SE-2G-30.3= through ONS-SE-2G-60.6= |
OC-48, STM-16 |
0 to +4 |
–28 to –9 |
ONS-SE-2G-L2= |
OC-48, STM-16 |
–2.0 to 3.0 |
–22 to –9 |
ONS-SE-2G-S1= |
OC-48, STM-16 |
–10 to –3 |
–28 to –9 |
ONS-SE-Z1= |
OC-3, OC-12, OC48, STM-1, STM-4, STM-16 |
–5.0 to 0 |
–23 to –3 (155.52/ 622.08 Mbps) –19 to –3 (1250 Mbps) –18 to 0 (2488.32 Mbps) |
ONS-SI-155-I1= |
OC-3, STM-1 |
–15 to –8.0 |
–28 to –8 |
ONS-SI-155-L1= |
OC-3, STM-1 |
–5.0 to 0 |
–34 to –10 |
ONS-SI-155-L2= |
OC-3, STM-1 |
–5.0 to 0 |
–34 to –10 |
ONS-SI-2G-I1= |
OC-48, STM-16 |
–5.0 to 0 |
–18 to –0 |
ONS-SI-2G-L1= |
OC-48, STM-16 |
–2 to +3 |
–27 to –9 |
ONS-SI-2G-L2= |
OC-48, STM-16 |
–2 to +3 |
–28 to –9 |
ONS-SI-2G-S1= |
OC-48, STM-16 |
–10 to –3 |
–18 to –3 |
ONS-SI-622-I1= |
OC-12, OC-3, STM-4, STM-1 |
–15 to –8.0 |
–28 to –8 |
ONS-SI-622-L1= |
OC-12, STM-4 |
–3.0 to 2.0 |
–28 to –8 |
ONS-SI-622-L2= |
OC-12, STM-4 |
–3.0 to 2.0 |
–28 to –8 |
15454-SFP-LC-SX=/ ONS-SC-GE-SX= |
Gigabit Ethernet (GE) |
–9.5 to –4 |
–17 to 0 |
15454-SFP-LC-LX=/ ONS-SC-GE-LX= |
GE |
–9.5 to –3 |
–19 to –3 |
15454-SFP3-1-IR= |
OC-3 |
–15 to –8 |
–28 to –8 |
15454E-SFP-L.1.1= |
STM-1 |
–15 to –8 |
–34 to –10 |
15454-SFP12-4-IR= |
OC-12, D1 Video |
–15 to –8 |
–28 to –7 |
15454E-SFP-L.4.1= |
STM-4, D1 Video |
–15 to –8 |
–28 to –8 |
15454-SFP-OC48-IR= |
OC-48, DV6000 (C-Cor) |
–5 to +0 |
–18 to +0 |
15454E-SFP-L.16.1= |
STM-16, DV6000 (C-Cor) |
–5 to +0 |
–18 to +0 |
15454-SFP-200=/ 15454E-SFP-200= |
Enterprise System Connection (ESCON) |
–20.5 to -15 |
–29 to –14 |
15454-SFP-GEFC-SX=/ 15454E-SFP-GEFC-S=/ ONS-SE-G2F-SX= |
Fibre Channel (1 and 2 Gbps), FICON, GE |
–10 to –3.5 |
–17 to 0 for 1FC, GE –15 for 2FC |
15454-SFP-GE+-LX=/ 15454E-SFP-GE+-LX=/ ONS-SE-G2F-LX |
Fibre Channel (1 and 2 Gbps), FICON, GE, High-definition television (HDTV) |
–9.5 to –3.0 |
–20 to –3 for 1FC, 2FC, and GE |
ONS-SI-155-SR-MM= |
OC-3, STM-1 |
–19 to –14 |
–14 to –5 |
ONS-SI-622-SR-MM= |
OC-12, STM-4 |
–19 to –14 |
–14 to –5 |
ONS-SC-Z3-1470= through ONS-SC-Z3-1610= |
OC48/STM16/GE |
0 to +5 |
–9 (min) |
ONS-SE-2G-1470= through ONS-SE-2G-1610= |
OC48/STM16/GE |
–1 to +4 |
–28 to –9 |
ONS-SE-Z1= |
OC-3/STM-1 OC-12/STM-4 OC-48/STM-16 Fibre Channel (1 and 2 Gbps) GE |
–5 to 0 |
–23 to –3 (OC-3) –23 to –3 (OC-12) –18 to 0 (OC-48) 0 to –21 (Fibre Channel) 0 to –22 (GE) |
ONS-SI-2G-S1 |
OC-48/STM-16 |
–10 to –3 |
–3 (min) |
ONS-SE-155-1470 through ONS-SE-155-1610 |
OC-3/STM-1 |
0 to 5 |
–7 to 0 |
ONS-SI-GE-ZX |
GE |
0 to +5 |
–23 to –3 |
ONS-SE-GE-ZX |
GE |
0 to +5 |
–23 to –3 |
ONS-SE-ZE-EL |
1000 Base-T Ethernet |
— |
— |
ONS-SE-GE-BXD= |
1000Base BXD/GE |
–9 to –3 |
–19.5 to –3 |
ONS-SE-GE-BXU= |
1000Base BXU/GE |
–9 to –3 |
–19.5 to –3 |
ONS-SC-EOP1= |
Fast Ethernet over DS1/E1 |
— |
— |
ONS-SC-EOP3= |
Fast Ethernet over DS3/E3 |
— |
— |
ONS-SC-E1-T1-PW= |
E1/DS1 over Fast Ethernet |
— |
— |
ONS-SC-E3-T3-PW- |
E3/DS3 PDH over Fast Ethernet |
— |
— |
ONS-SI-100-FX= |
Fast Ethernet |
–19.0 to –14 |
–31.0 to –14 |
ONS-SI-100-LX10= |
Fast Ethernet |
–15.0 to –8 |
–28 to –8 |
ONS-SC-OSC-ULH= |
OC3/STM1/FE OSC |
+1 to +5 |
43 to –7 |
ONS-SC-OSC-18.0= |
OC3/STM1/FE OSC for RAMAN 1518.0 nm signal |
+2.5 to +7 |
43 to –7 |
ONS-SE-155-1510= |
OC3/FE TNC OSC |
+1 to +5 |
43 to –7 |
ONS-SC-Z3-1510 |
GE TNC OSC |
0 to +5 |
–29 to –9 |
ONS-SC-HD3GV-TX= |
3G HD Video TX |
–3 to 0 |
–20 |
ONS-SC-HD3GV-RX= |
3G HD Video RX |
–3 to 0 |
–20 |
Important note for the following table:
The LED based SFPs ( ONS-SI-100-FX) do not support the optical power transmitted (OPT) and laser bias current (LBC) optical parameters.
The ONS-SC-155-TSOP, and ONS-SC-622-TSOP SFPs are partially supported in Cisco CPT Software Release 9.5.3 onwards. Following is the list of supported features:
SFP |
Interface |
Transmitter Output Power Min/Max (dBm) |
Receiver Input Power Min/Max (dBm) |
---|---|---|---|
ONS-SC-2G-28.7= through ONS-SC-2G-60.6= |
OC-48, STM-16 |
0 to +4 |
–28 to –9 |
ONS-SE-2G-1470= through ONS-SE-2G-1610= |
OC48/STM16/GE |
–1 to +4 |
–28 to –9 |
ONS-SE-GE-BXD= |
1000Base BXD/GE |
–9 to –3 |
–19.5 to –3 |
ONS-SE-GE-BXU= |
1000Base BXU/GE |
–9 to –3 |
–19.5 to –3 |
ONS-SE-ZE-EL |
1000 Base-T Ethernet |
— |
— |
ONS-SI-100-FX= |
Fast Ethernet |
–19.0 to –14 |
–31.0 to –14 |
ONS-SI-100-LX10= |
Fast Ethernet |
–15.0 to –8 |
–28 to –8 |
ONS-SI-GE-ZX |
GE |
0 to +5 |
–23 to –3 |
ONS-SC-E1-T1-CES= |
E1/DS1 over Gigabit Ethernet (when SyncE clock is used) |
— |
— |
ONS-SC-E3-T3-CES= |
E3/DS3 PDH over Gigabit Ethernet (when SyncE clock is used) |
— |
— |
ONS-SC-155-TSOP |
OC3/STM1 |
-5 to 0 |
-34 to -10 |
ONS-SC-622-TSOP |
OC12/STM4 |
-3 to +2 |
-28 to -8 |
The following table lists specifications for available SFP+ modules.
Table 15 provides cabling specifications for the SMF SFPs, Table 16 provides cabling specifications for MMF SFPs, Table 17 provides cabling specifications of video SFPs, Table 18 provides cabling specifications for SMF SFP+ modules, and Table 19 provides cabling specifications for MMF SFP+ modules that you install into interface cards. The ports of the listed SFP and SFP+ modules have LC-type connectors.
Table 6 provides cabling specifications for the SMF SFPs, Table 7 provides cabling specifications for MMF SFPs, Table 8 provides cabling specifications for SMF SFP+ modules, Table 9 provides cabling specifications for MMF SFP+ modules, and Table 10 provides cabling specifications for copper SFP+ modules that you install into interface cards. The ports of the listed SFP and SFP+ modules have LC-type connectors.
The following table provides cabling specifications for the SMF SFPs.
Important notes for the following table:
Typical loss on a 1310 nm wavelength SMF is 0.6 dB/km.
The ONS-SC-2G-28.7, ONS-SC-2G-33.4, ONS-SC-2G-41.3, ONS-SC-2G-49.3, and ONS-SC-2G-57.3 SFPs are supported in Cisco ONS Software Release 8.5 and later releases.
The ONS-SC-2G-xx.x cable distance varies depending on the DWDM system installation.
The ONS-SC-2G-37.4, ONS-SC-2G-45.3, and ONS-SC-2G-53.3 SFPs are supported in Cisco ONS Software Release 9.4 and later releases.
SFP |
Transmit Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-SC-2G-28.7= |
1528.70 nm |
9 micron SMF |
N/A |
ONS-SC-2G-30.3= |
1530.33 nm |
9 micron SMF |
N/A |
ONS-SC-2G-31.1= |
1531.12 nm |
9 micron SMF |
N/A |
ONS-SC-2G-31.9= |
1531.90 nm |
9 micron SMF |
N/A |
ONS-SC-2G-32.6= |
1532.68 nm |
9 micron SMF |
N/A |
ONS-SC-2G-33.4= |
1533.47 nm |
9 micron SMF |
N/A |
ONS-SC-2G-34.2= |
1534.25 nm |
9 micron SMF |
N/A |
ONS-SC-2G-35.0= |
1535.04 nm |
9 micron SMF |
N/A |
ONS-SC-2G-35.8= |
1535.82 nm |
9 micron SMF |
N/A |
ONS-SC-2G-36.6= |
1536.61 nm |
9 micron SMF |
N/A |
ONS-SC-2G-37.4= |
1537.40 nm |
9 micron SMF |
N/A |
ONS-SC-2G-38.1= |
1538.19 nm |
9 micron SMF |
N/A |
ONS-SC-2G-38.9= |
1538.98 nm |
9 micron SMF |
N/A |
ONS-SC-2G-39.7= |
1539.77 nm |
9 micron SMF |
N/A |
ONS-SC-2G-40.5= |
1540.56 nm |
9 micron SMF |
N/A |
ONS-SC-2G-41.3= |
1541.35 nm |
9 micron SMF |
N/A |
ONS-SC-2G-42.1= |
1542.14 nm |
9 micron SMF |
N/A |
ONS-SC-2G-42.9= |
1542.94 nm |
9 micron SMF |
N/A |
ONS-SC-2G-43.7= |
1543.73 nm |
9 micron SMF |
N/A |
ONS-SC-2G-44.5= |
1544.53 nm |
9 micron SMF |
N/A |
ONS-SC-2G-45.3= |
1545.32 nm |
9 micron SMF |
N/A |
ONS-SC-2G-46.1= |
1546.12 nm |
9 micron SMF |
N/A |
ONS-SC-2G-46.9= |
1546.92 nm |
9 micron SMF |
N/A |
ONS-SC-2G-47.7= |
1547.72 nm |
9 micron SMF |
N/A |
ONS-SC-2G-48.5= |
1548.51 nm |
9 micron SMF |
N/A |
ONS-SC-2G-49.3= |
1549.32 nm |
9 micron SMF |
N/A |
ONS-SC-2G-50.1= |
1550.12 nm |
9 micron SMF |
N/A |
ONS-SC-2G-50.9= |
1550.92 nm |
9 micron SMF |
N/A |
ONS-SC-2G-51.7= |
1551.72 nm |
9 micron SMF |
N/A |
ONS-SC-2G-52.5= |
1552.52 nm |
9 micron SMF |
N/A |
ONS-SC-2G-53.3= |
1553.33 nm |
9 micron SMF |
N/A |
ONS-SC-2G-54.1= |
1554.13 nm |
9 micron SMF |
N/A |
ONS-SC-2G-54.9= |
1554.94 nm |
9 micron SMF |
N/A |
ONS-SC-2G-55.7= |
1555.75 nm |
9 micron SMF |
N/A |
ONS-SC-2G-56.5= |
1556.55 nm |
9 micron SMF |
N/A |
ONS-SC-2G-57.3= |
1557.36 nm |
9 micron SMF |
N/A |
ONS-SC-2G-58.1= |
1558.17 nm |
9 micron SMF |
N/A |
ONS-SC-2G-58.9= |
1558.98 nm |
9 micron SMF |
N/A |
ONS-SC-2G-59.7= |
1559.79 nm |
9 micron SMF |
N/A |
ONS-SC-2G-60.6= |
1560.61 nm |
9 micron SMF |
N/A |
ONS-SE-155-1470= |
1470 nm |
9 micron SMF |
120 km (74.56 miles) |
ONS-SE-155-1490= |
1490 nm |
9 micron SMF |
120 km (74.56 miles) |
ONS-SE-155-1510= |
1510 nm |
9 micron SMF |
120 km (74.56 miles) |
ONS-SE-155-1530= |
1530 nm |
9 micron SMF |
120 km (74.56 miles) |
ONS-SE-155-1550= |
1550 nm |
9 micron SMF |
120 km (74.56 miles) |
ONS-SE-155-1570= |
1570 nm |
9 micron SMF |
120 km (74.56 miles) |
ONS-SE-155-1590= |
1590 nm |
9 micron SMF |
120 km (74.56 miles) |
ONS-SE-155-1610= |
1610 nm |
9 micron SMF |
120 km (74.56 miles) |
ONS-SE-622-1470= |
1470 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1490= |
1490 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1510= |
1510 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1530= |
1530 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1550= |
1550 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1570= |
1570 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1590= |
1590 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1610= |
1610 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-2G-L2= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-2G-S1= Short Reach |
1310 nm |
9 micron SMF |
2 km (1.2 miles) |
ONS-SE-4G-SM= |
1270 – 1355 nm |
9 micron SMF |
10 km (6.2 miles) |
ONS-SE-Z1= |
1310 nm |
9 micron SMF |
15 km (9.3 miles) |
ONS-SI-155-I1= Intermediate Reach |
1310 nm |
9 micron SMF |
21 km (13.05 miles) |
ONS-SI-155-L1= Long Reach |
1310 nm |
9 micron SMF |
50 km (31.07 miles) |
ONS-SI-155-L2= Long Reach |
1550 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SI-2G-I1= |
1310 nm |
9 micron SMF |
15 km (9.3 miles) |
ONS-SI-2G-L1= |
1310 nm |
9 micron SMF |
40 km (25.80 miles) |
ONS-SI-2G-L2= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SI-2G-S1= |
1310 nm |
9 micron SMF |
2 km (1.2 miles) |
ONS-SI-622-I1= Intermediate Reach |
1310 nm |
9 micron SMF |
21 km (13.05 miles) |
ONS-SI-622-L1= Long Reach |
1310 nm |
9 micron SMF |
42 km (26.10 miles) |
ONS-SI-622-L2= Long Reach |
1550 nm |
9 micron SMF |
85 km (52.82 miles) |
15454-SFP-LC-LX=/ 15454E-SFP-LC-LX=/ ONS-SC-GE-LX Long Reach |
1310 nm |
9 micron SMF |
10 km (6.2 miles) |
15454-SFP3-1-IR= Intermediate Reach |
1310 nm |
9 micron SMF |
15 km (9.3 miles) |
15454E-SFP-L.1.1= Short Haul |
1310 nm |
9 micron SMF |
15 km (9.3 miles) |
15454-SFP12-4-IR= Intermediate Reach |
1310 nm |
9 micron SMF |
15 km (9.3 miles) |
15600-SFP-12-4-LR2= |
1530 nm |
9 micron SMF |
80 km (49.71 miles) |
15454E-SFP-L.4.1= Short Haul |
1310 nm |
9 micron SMF |
15 km (9.3 miles) |
15454-SFP-OC48-IR= Intermediate Reach |
1310 nm |
9 micron SMF |
15 km (9.3 miles) |
15454E-SFP-L.16.1= Short Haul |
1310 nm |
9 micron SMF |
15 km (9.3 miles) |
15454-SFP-GE+-LX=/ 15454E-SFP-GE+-LX= Long Reach |
1310 nm |
9 micron SMF |
10 km (6.2 miles) for FC 1G, FC 2G, and GE 5 km (3.1 miles) for HDTV |
ONS-SC-Z3-1470= Long Reach |
1470 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-Z3-1490= Long Reach |
1490 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-Z3-1510= Long Reach |
1510 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-Z3-1530= Long Reach |
1530 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-Z3-1550= Long Reach |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-Z3-1570= Long Reach |
1570 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-Z3-1590= Long Reach |
1590 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-Z3-1610= Long Reach |
1610 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-Z1= Intermediate Reach |
1310 nm |
9 micron SMF |
30 km (18.6 miles) for OC-3/STM1, OC-12/STM-4, OC-48/STM-16, and Fibre Channel (1 and 2 Gbps) 20 km (12.4 miles) for GE |
ONS-SI-2G-S1= Short Reach |
1310 nm |
9 micron SMF |
2 km (1.2 miles) |
ONS-SE-155-1470= Long Reach |
1470 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-155-1490= Long Reach |
1490 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-155-1510= Long Reach |
1510 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-155-1530= Long Reach |
1530 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-155-1550= Long Reach |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-155-1570= Long Reach |
1570 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-155-1590= Long Reach |
1590 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-155-1610= Long Reach |
1610 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-622-1470= Long Reach |
1470 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1490= Long Reach |
1490 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1510= Long Reach |
1510 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1530= Long Reach |
1530 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1550= Long Reach |
1550 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1570= Long Reach |
1570 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1590= Long Reach |
1590 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SE-622-1610= Long Reach |
1610 nm |
9 micron SMF |
100 km (62.14 miles) |
ONS-SI-GE-ZX= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-GE-ZX= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-GE-BXD= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-GE-BXU= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-EOP1= |
— |
9 micron SMF |
2.5 km (1.56 miles) |
ONS-SC-EOP3= |
— |
9 micron SMF |
2.5 km (1.56 miles) |
ONS-SC-E1-T1-PW= |
— |
9 micron SMF |
1.83 km (1.136 miles) |
ONS-SC-E3-T3-PW= |
— |
9 micron SMF |
1.83 km (1.136 miles) |
ONS-SC-E1-T1-CES= |
— |
9 micron SMF |
1.83 km (1.136 miles) |
ONS-SC-E3-T3-CES= |
— |
9 micron SMF |
1.83 km (1.136 miles) |
ONS-SI-100-LX10= |
1310 nm |
9 micron SMF |
2 km (1.24 miles) |
ONS-SC-OSC-ULH= |
1500 – 1520 nm |
9 micron SMF |
160 km (99.41 miles) |
ONS-SC-OSC-18.0= |
1518 nm |
— |
— |
SFP |
Transmit Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-SC-2G-28.7= |
1528.70 nm |
9 micron SMF |
N/A |
ONS-SC-2G-30.3= |
1530.33 nm |
9 micron SMF |
N/A |
ONS-SC-2G-31.1= |
1531.12 nm |
9 micron SMF |
N/A |
ONS-SC-2G-31.9= |
1531.90 nm |
9 micron SMF |
N/A |
ONS-SC-2G-32.6= |
1532.68 nm |
9 micron SMF |
N/A |
ONS-SC-2G-33.4= |
1533.47 nm |
9 micron SMF |
N/A |
ONS-SC-2G-34.2= |
1534.25 nm |
9 micron SMF |
N/A |
ONS-SC-2G-35.0= |
1535.04 nm |
9 micron SMF |
N/A |
ONS-SC-2G-35.8= |
1535.82 nm |
9 micron SMF |
N/A |
ONS-SC-2G-36.6= |
1536.61 nm |
9 micron SMF |
N/A |
ONS-SC-2G-37.4= |
1537.40 nm |
9 micron SMF |
N/A |
ONS-SC-2G-38.1= |
1538.19 nm |
9 micron SMF |
N/A |
ONS-SC-2G-38.9= |
1538.98 nm |
9 micron SMF |
N/A |
ONS-SC-2G-39.7= |
1539.77 nm |
9 micron SMF |
N/A |
ONS-SC-2G-40.5= |
1540.56 nm |
9 micron SMF |
N/A |
ONS-SC-2G-41.3= |
1541.35 nm |
9 micron SMF |
N/A |
ONS-SC-2G-42.1= |
1542.14 nm |
9 micron SMF |
N/A |
ONS-SC-2G-42.9= |
1542.94 nm |
9 micron SMF |
N/A |
ONS-SC-2G-43.7= |
1543.73 nm |
9 micron SMF |
N/A |
ONS-SC-2G-44.5= |
1544.53 nm |
9 micron SMF |
N/A |
ONS-SC-2G-45.3= |
1545.32 nm |
9 micron SMF |
N/A |
ONS-SC-2G-46.1= |
1546.12 nm |
9 micron SMF |
N/A |
ONS-SC-2G-46.9= |
1546.92 nm |
9 micron SMF |
N/A |
ONS-SC-2G-47.7= |
1547.72 nm |
9 micron SMF |
N/A |
ONS-SC-2G-48.5= |
1548.51 nm |
9 micron SMF |
N/A |
ONS-SC-2G-49.3= |
1549.32 nm |
9 micron SMF |
N/A |
ONS-SC-2G-50.1= |
1550.12 nm |
9 micron SMF |
N/A |
ONS-SC-2G-50.9= |
1550.92 nm |
9 micron SMF |
N/A |
ONS-SC-2G-51.7= |
1551.72 nm |
9 micron SMF |
N/A |
ONS-SC-2G-52.5= |
1552.52 nm |
9 micron SMF |
N/A |
ONS-SC-2G-53.3= |
1553.33 nm |
9 micron SMF |
N/A |
ONS-SC-2G-54.1= |
1554.13 nm |
9 micron SMF |
N/A |
ONS-SC-2G-54.9= |
1554.94 nm |
9 micron SMF |
N/A |
ONS-SC-2G-55.7= |
1555.75 nm |
9 micron SMF |
N/A |
ONS-SC-2G-56.5= |
1556.55 nm |
9 micron SMF |
N/A |
ONS-SC-2G-57.3= |
1557.36 nm |
9 micron SMF |
N/A |
ONS-SC-2G-58.1= |
1558.17 nm |
9 micron SMF |
N/A |
ONS-SC-2G-58.9= |
1558.98 nm |
9 micron SMF |
N/A |
ONS-SC-2G-59.7= |
1559.79 nm |
9 micron SMF |
N/A |
ONS-SC-2G-60.6= |
1560.61 nm |
9 micron SMF |
N/A |
ONS-SI-GE-ZX= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-GE-BXD= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SE-GE-BXU= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC-E1-T1-CES= |
— |
9 micron SMF |
1.83 km (1.136 miles) |
ONS-SC-E3-T3-CES= |
— |
9 micron SMF |
1.83 km (1.136 miles) |
ONS-SI-100-LX10= |
1310 nm |
9 micron SMF |
2 km (1.24 miles) |
ONS-SC-155-TSOP |
1310 nm |
9 micron SMF |
40 km (24.85 miles) |
ONS-SC-622-TSOP |
1310 nm |
9 micron SMF |
40 km (24.85 miles) |
The following table provides cabling specifications for the MMF SFPs.
SFP |
Transmit Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-SE-4G-MM= |
830 – 860 nm |
62.5 micron MMF |
300 m (984 ft) |
50.0 micron MMF |
500 m (1640 ft) |
||
ONS-SE-100-FX= |
1270 – 1380 nm |
MMF |
2 km (1.24 miles) |
ONS-SE-100-LX10= |
1260 – 1360 nm |
MMF |
15 km (9.32 miles) |
15454-SFP-LC-SX= Short Reach |
850 nm |
62.5 micron MMF |
220 m (722 ft) 275 m (902 ft) |
50.0 micron MMF |
500 m (1640 ft) 550 m (1804 ft) |
||
15454-SFP-LC-LX= Long Reach |
1310 nm |
62.5 micron MMF |
550 m (1804 ft) |
50.0 micron MMF |
550 m (1804 ft) |
||
15454-SFP-200= Long Reach |
1310 nm |
62.5 micron MMF |
2 km (1.2 miles) |
ONS-SE-200-MM= |
1310 nm |
62.5 micron MMF |
2 km (1.2 miles) |
15454-SFP-GEFC-SX= Short Reach |
850 nm |
62.5 micron MMF |
300 m (984 ft) for FC 1 Gbps and GE 150 m (492 ft) for FC 2 Gbps |
50.0 micron MMF |
550 m (1804 ft) for FC 1 Gbps and GE 300 m (984 ft) for FC 2 Gbps |
||
ONS-SI-155-SR-MM= Intermediate Reach |
1310 nm |
62.5/125 micron MMF |
2 km (1.2 miles) |
ONS-SI-622-SR-MM= Intermediate Reach |
1310 nm |
62.5/125 micron MMF |
2 km (1.2 miles) |
ONS-SI-100-FX= |
1310 nm |
MMF |
2 km (1.24 miles) |
The following table provides cabling specifications for the SMF SFP+ modules.
SFP+ |
Transmit Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-SC+-10G-ER= |
1550 nm |
9 micron SMF |
40 km (24.85 miles) |
ONS-SC+-10G-LR= |
1310 nm |
9 micron SMF |
10 km (6.214 miles) |
ONS-SC+-10G-ZR= |
1550 nm |
9 micron SMF |
80 km (49.71 miles) |
ONS-SC+-10G-1470 |
1471 nm |
9 micron SMF | 40 km (24.9 miles) |
ONS-SC+-10G-1490 |
1491 nm |
9 micron SMF | 40 km (24.9 miles) |
ONS-SC+-10G-1510 |
1511 nm |
9 micron SMF | 40 km (24.9 miles) |
ONS-SC+-10G-1530 |
1531 nm |
9 micron SMF | 40 km (24.9 miles) |
ONS-SC+-10G-1550 |
1551 nm |
9 micron SMF | 40 km (24.9 miles) |
ONS-SC+-10G-1570 |
1571 nm |
9 micron SMF | 40 km (24.9 miles) |
ONS-SC+-10G-1590 |
1591 nm |
9 micron SMF | 40 km (24.9 miles) |
ONS-SC+-10G-1610 |
1611 nm |
9 micron SMF | 40 km (24.9 miles) |
SFP+ |
Transmit Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-SC+-10G-ER= |
1550 nm |
9 micron SMF |
40 km (24.85 miles) |
ONS-SC+-10G-LR= |
1310 nm |
9 micron SMF |
10 km (6.214 miles) |
ONS-SC+-10G-LRM= |
1310 nm |
9 micron SMF |
220 m to 300 m |
ONS-SC+-10G-30.3= through ONS-SC+-10G-61.4= |
1530.3 - 1561.4 nm |
9 micron SMF |
40 km (24.85 miles) |
ONS-SC+-10G-EP30.3 through ONS-SC+-10G-EP61.4 |
1530.33 -1561.83 nm |
G.652 micron |
40km(24.85 miles) |
The following table provides cabling specifications for the MMF SFP+ modules.
SFP+ |
Transmit Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-SC+-10G-SR= |
840-860 nm |
62.5 micron FDDI-Grade |
26 m (85.3 ft) |
62.5 micron OM1 |
33 m (108.27 ft) |
||
50.0 micron |
66 m (216.54 ft) |
||
50.0 micron OM2 |
82 m (269 ft) |
||
50.0 micron OM3 |
300 m (984 ft) |
||
50.0 micron OM4 |
400 m (1312.36 ft) |
SFP+ |
Transmit Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-SC+-10G-SR= |
840-860 nm |
62.5 micron FDDI-Grade |
26 m (85.3 ft) |
62.5 micron OM1 |
33 m (108.27 ft) |
||
50.0 micron |
66 m (216.54 ft) |
||
50.0 micron OM2 |
82 m (269 ft) |
||
50.0 micron OM3 |
300 m (984 ft) |
||
50.0 micron OM4 |
400 m (1312.36 ft) |
The 10 Gbps 1310 nm XFP transceiver is an integrated fiber optic transceiver that provides high-speed serial link at the following signaling rates—9.95 Gbps, 10.31 Gbps, 10.51 Gbps, and 10.66/10.71/11.10 Gbps. These rates apply to 10GBASE-LR (Fibre Channel and Ethernet) as well as OC-192/STM-64 SONET/SDH.
The XFP integrates the receiver and transmit path. The transmit side recovers and retimes the 10 Gbps serial data and passes it to a laser driver. The laser driver biases and modulates a 1310 nm DFB (distributed feedback) laser, enabling data transmission over SMF through an LC connector. The receive side recovers and retimes the 10 Gbps optical data stream from a positive-intrinsic-negative (PIN) photo detector, transimpedance amplifier and passes it to an output driver.
The XFP module uses the bail clasp latching mechanism as shown unlatched in the following figures. See the label on the XFP for technology type and model.
XFP module dimensions are:
XFP temperature ranges are:
COM—Commercial operating temperature range between 23 degrees Fahrenheit to 158 degrees Fahrenheit (-5 degrees Celsius to 70 degrees Celsius)
EXT—Extended operating temperature range between 23 degrees Fahrenheit it to 185 degrees Fahrenheit (-5 degrees Celsius to 85 degrees Celsius)
IND—Industrial operating temperature range between -40 degrees Fahrenheit to 185 degrees Fahrenheit (-40 degrees Celsius to 85 degrees Celsius)
Caution |
Do not add labels or markings to the XFP modules. |
The following table lists specifications for available XFPs.
Important notes for the following table:
The ONS-XC-10G-L2 XFP installed on a transponder card, must be installed in high-speed slots 5, 6, 12, or 13 for power dissipation when FTA-3 or FTA-48V is used. There is no restriction on the slots in which the ONS-XC-10G-L2-FXP is installed when CC-FTA is used.
The IB_5G payload is supported by ONS-XC-10G-S1 XFP P/N version 03 only.
XFP |
Interface |
Transmitter Output Power Min/Max (dBm) |
Receiver Input Power Min/Max (dBm) |
---|---|---|---|
ONS-XC-8G-MM= |
OC192/STM64/8GFC |
–8.2 to –1.5 |
0.151 mW (stressed received in OMA) |
ONS-XC-8G-SM= |
OC192/STM64/8GFC |
–8.4 to +0.5 |
–13.8 (–11.8 stressed) to +0.5 (targeting up to 10 km distance) |
ONS-XC-10G-C= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
0 to +3 |
–24 to –7 |
ONS-XC-10G-I2= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +2 |
–14 to +2 |
ONS-XC-10G-L2= |
OC-192/STM-64/10GE/10GFC/OTU2 |
0 to +4 |
–24 to –7 |
ONS-XC-10G-S1= |
OC-192/STM64/10GE/10GFC/IB_5G |
–6 to –1 –8.2 to +0.5 |
–11 to –1 –14.4 to +0.5 |
ONS-XC-10G-SR-MM= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–7.3 to –1 |
–9.9 to –1 |
ONS-XC-10G-30.3= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-31.1= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-31.9= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-32.6= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-33.4= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-34.2= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-35.0= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-35.8= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-36.6= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-37.4= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-38.1= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-38.9= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-39.7= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-40.5= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-41.3= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-42.1= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-42.9= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-43.7= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-44.5= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-45.3= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-46.1= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-46.9= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-47.7= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-48.5= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-49.3= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-50.1= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-50.9= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-51.7= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-52.5= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-53.3= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-54.1= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-54.9= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-55.7= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-56.5= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-57.3= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-58.1= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-58.9= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-59.7= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-60.6= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-61.4= |
OC-192/STM-64/10GE/10GFC/OTU2/IB_5G |
–1 to +3 |
–23 to –7 |
ONS-XC-10G-1470= |
OC-192/STM-64/10GE/10GFC/OTU2 |
+3 to +7 |
–14 to –0 |
ONS-XC-10G-1490= |
OC-192/STM-64/10GE/10GFC/OTU2 |
+3 to +7 |
–14 to –0 |
ONS-XC-10G-1510= |
OC-192/STM-64/10GE/10GFC/OTU2 |
+3 to +7 |
–14 to –0 |
ONS-XC-10G-1530= |
OC-192/STM-64/10GE/10GFC/OTU2 |
+3 to +7 |
–14 to –0 |
ONS-XC-10G-1550= |
OC-192/STM-64/10GE/10GFC/OTU2 |
+3 to +7 |
–14 to –0 |
ONS-XC-10G-1570= |
OC-192/STM-64/10GE/10GFC/OTU2 |
+3 to +7 |
–14 to –0 |
ONS-XC-10G-1590= |
OC-192/STM-64/10GE/10GFC/OTU2 |
+3 to +7 |
–14 to –0 |
ONS-XC-10G-1610= |
OC-192/STM-64/10GE/10GFC/OTU2 |
+3 to +7 |
–14 to –0 |
ONS-XC-10G-EP30.3= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP31.1= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP31.9= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP32.6= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP33.4= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP34.2= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP35.0= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP35.8= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP36.6= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP37.4= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP38.1= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP38.9= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP39.7= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP40.5= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP41.3= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP42.1= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP42.9= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP43.7= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP44.5= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP45.3= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP46.1= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP46.9= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP47.7= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP48.5= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP49.3= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP50.1= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP50.9= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP51.7= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP52.5= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP53.3= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP54.1= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP54.9= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP55.7= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP56.5= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP57.3= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP58.1= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP58.9= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP59.7= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP60.6= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
ONS-XC-10G-EP61.4= |
OC-192/STM-64/10GE/10GFC/OTU2 |
–1 to +3 |
–27 to –8 |
The following table lists specifications for single-mode fiber XFP port cabling.
Important note for the following table:
In CTC card view, ONS-XC-10G-1530 XFP shows the supported wavelength as 1530.33 nm. When you try to set the wavelength as 1530 nm, the PROV-MISMATCH alarm is raised.
XFP |
Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-XC-8G-SM= |
1550 nm |
SMF |
— |
ONS-XC-10G-C= |
1529.55 nm through 1561.83 nm, with ITU spacing |
SMF |
80 km (49.71 miles) for OC-192/STM64/10GE |
ONS-XC-10G-I2= |
Receiver: 1260 nm to 1565 nm Transmitter: 1530 nm to 1565 nm |
SMF |
40 km (25.80 miles) for OC-192/STM64 |
ONS-XC-10G-L2= |
Transmitter: 1530 nm to 1565 nm Receiver: 1260 nm to 1565 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-S1= |
1310 nm |
SMF |
10 km (6.2 miles) for 10GE/10GFC 2 km (1.2 miles) for OC-192/STM64 |
ONS-XC-10G-29.9= |
1529.95 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-30.3= |
1530.33 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-31.1= |
1531.12 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-31.9= |
1531.90 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-32.6= |
1532.68 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-33.4= |
1533.47 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-34.2= |
1534.25 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-35.0= |
1535.04 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-35.8= |
1535.82 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-36.6= |
1536.61 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-37.4= |
1537.40 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-38.1= |
1538.19 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-38.9= |
1538.98 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-39.7= |
1539.77 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-40.5= |
1540.56 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-41.3= |
1541.35 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-42.1= |
1542.14 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-42.9= |
1542.94 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-43.7= |
1543.73 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-44.5= |
1544.53 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-45.3= |
1545.32 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-46.1= |
1546.12 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-46.9= |
1546.92 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-47.7= |
1547.72 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-48.5= |
1548.51 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-49.3= |
1549.32 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-50.1= |
1550.12 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-50.9= |
1550.92 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-51.7= |
1551.72 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-52.5= |
1552.52 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-53.3= |
1553.33 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-54.1= |
1554.13 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-54.9= |
1554.94 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-55.7= |
1555.75 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-56.5= |
1556.55 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-57.3= |
1557.36 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-58.1= |
1558.17 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-58.9= |
1558.98 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-59.7= |
1559.79 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-60.6= |
1560.61 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-61.4= |
1561.43 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-1470= |
1470 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1490= |
1490 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1510= |
1510 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1530= |
1530 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1550= |
1550 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1570= |
1570 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1590= |
1590 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1610= |
1610 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-EP30.3= |
1530.33 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP31.1= |
1531.12 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP31.9= |
1531.90 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP32.6= |
1532.68 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP33.4= |
1533.47 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP34.2= |
1534.25 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP35.0= |
1535.04 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP35.8= |
1535.82 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP36.6= |
1536.61 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP37.4= |
1537.40 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP38.1= |
1538.19 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP38.9= |
1538.98 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP39.7= |
1539.77 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP40.5= |
1540.56 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP41.3= |
1541.35 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP42.1= |
1542.14 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP42.9= |
1542.94 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP43.7= |
1543.73 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP44.5= |
1544.53 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP45.3= |
1545.32 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP46.1= |
1546.12 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP46.9= |
1546.92 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP47.7= |
1547.72 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP48.5= |
1548.51 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP49.3= |
1549.32 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP50.1= |
1550.12 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP50.9= |
1550.92 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP51.7= |
1551.72 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP52.5= |
1552.52 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP53.3= |
1553.33 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP54.1= |
1554.13 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP54.9= |
1554.94 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP55.7= |
1555.75 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP56.5= |
1556.55 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP57.3= |
1557.36 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP58.1= |
1558.17 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP58.9= |
1558.98 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP59.7= |
1559.79 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP60.6= |
1560.61 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP61.4= |
1561.43 nm |
SMF |
50 km (31.1 miles) |
XFP |
Wavelength |
Fiber Type |
Cable Distance |
---|---|---|---|
ONS-XC-10G-C= |
1529.55 nm through 1561.83 nm, with ITU spacing |
SMF |
80 km (49.71 miles) for OC-192/STM64/10GE |
ONS-XC-10G-I2= |
Receiver: 1260 nm to 1565 nm Transmitter: 1530 nm to 1565 nm |
SMF |
40 km (25.80 miles) for OC-192/STM64 |
ONS-XC-10G-L2= |
Transmitter: 1530 nm to 1565 nm Receiver: 1260 nm to 1565 nm |
SMF |
80 km (49.71 miles) for OC-192/STM64 |
ONS-XC-10G-S1= |
1310 nm |
SMF |
10 km (6.2 miles) for 10GE/10GFC 2 km (1.2 miles) for OC-192/STM64 |
ONS-XC-10G-1470= |
1470 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1490= |
1490 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1510= |
1510 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1530= |
1530 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1550= |
1550 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1570= |
1570 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1590= |
1590 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-1610= |
1610 nm |
SMF |
40 km (25.80 miles) for OTU2 and 10GE 10 km (6.2 miles) for OC192/STM64 |
ONS-XC-10G-EP30.3= |
1530.33 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP31.1= |
1531.12 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP31.9= |
1531.90 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP32.6= |
1532.68 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP33.4= |
1533.47 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP34.2= |
1534.25 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP35.0= |
1535.04 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP35.8= |
1535.82 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP36.6= |
1536.61 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP37.4= |
1537.40 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP38.1= |
1538.19 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP38.9= |
1538.98 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP39.7= |
1539.77 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP40.5= |
1540.56 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP41.3= |
1541.35 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP42.1= |
1542.14 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP42.9= |
1542.94 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP43.7= |
1543.73 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP44.5= |
1544.53 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP45.3= |
1545.32 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP46.1= |
1546.12 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP46.9= |
1546.92 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP47.7= |
1547.72 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP48.5= |
1548.51 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP49.3= |
1549.32 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP50.1= |
1550.12 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP50.9= |
1550.92 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP51.7= |
1551.72 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP52.5= |
1552.52 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP53.3= |
1553.33 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP54.1= |
1554.13 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP54.9= |
1554.94 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP55.7= |
1555.75 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP56.5= |
1556.55 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP57.3= |
1557.36 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP58.1= |
1558.17 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP58.9= |
1558.98 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP59.7= |
1559.79 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP60.6= |
1560.61 nm |
SMF |
50 km (31.1 miles) |
ONS-XC-10G-EP61.4= |
1561.43 nm |
SMF |
50 km (31.1 miles) |
The following table lists specifications for multimode fiber XFP port cabling.
Warning |
GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP modules are Class I laser products. Statement 1008 |
Warning |
Invisible laser radiation could be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm could pose an eye hazard. Statement 1056 |
Warning |
Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 |
Warning |
Use of controls, adjustments, or performing procedures other than those specified may result in hazardous radiation exposure. Statement 1057 |
Warning |
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself. Statement 94 |
Warning |
Before you install, operate, or service the system, read the Site Preparation and Safety Guide. This guide contains important safety information you should know before working with the system. |
Warning |
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 148 |
Warning |
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety, for Ethernet RJ-45 ports, use only shielded Ethernet cables that are grounded on both ends. In a NEBS installation, all Ethernet ports are limited to intra-building wiring. Statement 7012 |
Warning |
Ethernet ports are intra-building ports and are suitable only for connecting to shielded cabling grounded at both ends. Statement 1084 |
Caution |
Do not use GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP modules from third-party vendors. Cisco TAC does not support third-party vendor GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP modules. A third-party vendor GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP modules is any GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, or XFP module that is not sourced from Cisco directly, or via a Cisco Partner, or Cisco authorized seller. Cisco-sourced GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP modules can be identified by the Cisco label and logo. |
Note |
GBICs and SFPs must be matched on either end by type: SX to SX, LX/LH to LX/LH, or ZX to ZX (GBIC). |
Note |
The shelf should be equipped with a CC-FAN if the copper SFP is installed on a MXP_MR_10DME card. |
Purpose |
This task installs, provisions, and deletes PPMs (GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP modules) on the line cards. Because GBICs, SFP, SFP+, XFP, CXP, CFP, and CPAKSFP, SFP+, and XFP modules are hot-swappable, they can be installed and removed while the card/shelf assembly is powered and running. |
Tools/Equipment |
|
Prerequisite Procedures |
"NTP-G179 Install the TXP, MXP, AR_MXP, AR_XP, 100G-LC-C, 10x10G-LC, CFP-LC, ADM-10G, and OTU2_XP Cards" task in the chapter "Provision Transponder and Muxponder Cards" of Cisco ONS 15454 DWDM Configuration Guide "NTP-J19 Install the Fabric and Line Cards" task in the chapter "Hardware" of Cisco CPT Configuration Guide. |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite |
Security Level |
Provisioning or higher |
Purpose |
This task installs PPM on a line card. The PPMs provide a fiber interface to the card. |
Tools/Equipment |
|
Prerequisite Procedures |
"NTP-G179 Install the TXP, MXP, AR_MXP, AR_XP, 100G-LC-C, 10x10G-LC, CFP-LC, ADM-10G, and OTU2_XP Cards" task in the chapter "Provision Transponder and Muxponder Cards" of Cisco ONS 15454 DWDM Line Card Configuration Guide. "NTP-J19 Install the Fabric and Line Cards" task in the chapter "Hardware" of Cisco CPT Configuration Guide. |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite |
Security Level |
Provisioning or higher |
Warning |
GBICs, SFP, SFP+, XFP, CXP, and CFPSFP, SFP+, and XFP modules are Class I laser products. Statement 1008 |
Warning |
Because invisible laser radiation may be emitted from the aperture of the port when no cable is connected, avoid exposure to laser radiation and do not stare into open apertures. Statement 70 |
Warning |
Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 |
Warning |
Use of controls, adjustments, or performing procedures other than those specified may result in hazardous radiation exposure. Statement 1057 |
Warning |
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety, connect the serial high-speed WAN interface ports only to intra-building or unexposed wiring or cable. The intrabuilding cable must be shielded and the shield must be grounded at both ends. The intra-building port(s) of the equipment or subassembly must not be metallically connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring. Statement 7003 |
Note |
In case of a full C-band tunable XFP, it is mandatory to use optical cables that are fully compliant with NEBS Telcordia GR-326-CORE, Issue 3 recommendation. |
Step 1 | Verify that the GBICs, SFP, SFP+, XFP, CXP, or CFPSFP, SFP+, or XFP module is correct for your network. Ensure that you are installing compatible GBICs, SFP, SFP+, XFP, CXP, or CFPSFP, SFP+, or XFP module, for example, SX to SX or LX/LH to LX/LH. | ||
Step 2 | Remove the PPM from its protective packaging. | ||
Step 3 |
Check the label to verify that the PPM is the correct type for your network. Table 1 through Table 1 shows the available GBICs, SFP, XFP, CFP, and CXP modules.
|
||
Step 4 |
Verify the type of PPM you are using:
|
||
Step 5 |
Install GBICs with clips. Perform the following:
|
||
Step 6 |
Install GBICs with a handle. Perform the following:
|
||
Step 7 |
Install the SFP, SFP+, XFP, or CXPSFP, SFP+, or XFP module. Perform the following:
|
||
Step 8 |
Install CFP module. Perform the following:
|
||
Step 9 | Return to your originating procedure (NTP). |
To connect the single-mode or multimode optical fiber, attach the appropriate optical fiber cable directly to the SC-type receptacle on the GBIC or the LC-type connector on the SFP, SFP+, or XFP module. You can use either simplex or duplex connectors for most devices. For simplex connectors, two cables are required, one cable for transmit (Tx) and a second cable for receive (Rx). For duplex connectors, only one cable that has both Tx and Rx connectors is required.
Purpose |
This task preprovisions PPM (GBIC, SFP, SFP+, XFP, CXP, or CFPSFP, SFP+, or XFP) slot. |
Tools/Equipment |
None |
Prerequisite Procedures |
"DLP-G46 Log into CTC" in the Connect the PC and Log into the GUI document. "NTP-J22 Log into CTC" task in the chapter "Understanding the Carrier Packet Transport System" of Cisco CPT Configuration Guide. |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite or remote |
Security Level |
Provisioning or higher |
Note |
GBIC, SFP, SFP+, XFP, CXP, or CFPSFP, SFP+, and XFP modules are generically called PPMs in CTC. After installing multirate GBIC, SFP, SFP+, XFP, CXP, or CFPSFP, SFP+, and XFP modules, multirate PPMs must be provisioned in CTC. To complete the provisioning of the multirate pluggable port, complete the DLP-G726 Preprovisioning a Multirate PPM task. |
Step 1 | In node view (single-shelf mode) or shelf view (multishelf mode), double-click the card where you want to provision PPM settings. | ||
Step 2 | Click the Provisioning > Pluggable Port Modules tabs. | ||
Step 3 | In the Pluggable Port Modules area, click Create. The Create PPM dialog box appears. | ||
Step 4 |
In the Create PPM dialog box, complete the following:
|
||
Step 5 |
Click OK. The newly created port appears in the Pluggable Port Modules pane. The row in the Pluggable Port Modules pane turns light blue. The Actual Equipment Type column remains blank until the actual GBIC, SFP, SFP+, XFP, CXP, or CFPSFP, SFP+, or XFP module is installed. After the GBIC, SFP, SFP+, XFP, CXP, or CFPSFP, SFP+, or XFP module is installed, the row in the pane turns white and the Actual Equipment Type column shows the equipment name.
|
||
Step 6 | Verify that the PPM appears in the list in the Pluggable Port Modules pane. If it does not, repeat Step Step 3 through Step Step 5. | ||
Step 7 | Repeat Step Step 2 through Step Step 5 to provision a second PPM, if needed. If not, continue with Step Step 8. | ||
Step 8 | Click OK. | ||
Step 9 | Return to your originating procedure (NTP). |
Purpose |
This task provisions a multirate PPM on a line card. |
Tools/Equipment |
None |
Prerequisite Procedures |
"DLP-G46 Log into CTC" in the Connect the PC and Log into the GUI document. "NTP-J22 Log into CTC" task in the chapter "Understanding the Carrier Packet Transport System" of Cisco CPT Configuration Guide. |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite or remote |
Security Level |
Provisioning or higher |
Note |
If the PPM was preprovisioned using the DLP-G725 Preprovisioning PPM Slot task, this task is unnecessary, unless the PPM has an Out-of-Service and Autonomous Management, Unassigned (ANSI) or Unlocked-disabled, unassigned (ETSI) service state. |
Step 1 | In node view (single-shelf mode) or shelf view (multishelf view), double-click the line card where you want to provision the multirate PPM settings. |
Step 2 |
If this is the first multirate PPM provisioned for the card, continue with Step 3. If not, complete the following steps.
|
Step 3 | Click the Provisioning > Pluggable Port Modules tabs. |
Step 4 | In the Pluggable Port Modules area, click Create. The Create PPM dialog box appears. |
Step 5 | In the Create PPM dialog box, complete the following: |
Step 6 | Click OK. The newly created port appears in the Pluggable Port Modules area. The row in the Pluggable Port Modules area turns white and the Actual Equipment Type column lists the equipment name. |
Step 7 | If you want to provision a PPM on another port, repeat Step 3 through Step Step 5. |
Step 8 | Return to your originating procedure (NTP). |
Before deleting a PPM, delete the PPM from the provisioning pane.
This task does not apply to the TXP_MR_10G card. To change the TXP_MR_10G data rate, see the section "DLP-G365 Provision the TXP_MR_10G Data Rate" in the chapter "Provision Transponder and Muxponder Cards" of Cisco ONS 15454 DWDM Configuration Guide.
You cannot delete a PPM if the TXP, MXP, AR_MXP, AR_XP, GE_XP, 10GE_XP, GE_XPE, 10GE_XPE, or ADM-10G card is part of a regenerator group. For OTU2_XP card, you cannot delete a PPM if the card configuration is in Standard Regen or Enhanced FEC mode.
Purpose |
This task deletes PPM provisioning for GBICs, SFP, SFP+, XFP, CXP, and CFPSFP, SFP+, and XFP modules installed on the line cards. |
Tools/Equipment |
None |
Prerequisite Procedures |
"DLP-G46 Log into CTC" in the Connect the PC and Log into the GUI document. "NTP-J22 Log into CTC" task in the chapter "Understanding the Carrier Packet Transport System" of Cisco CPT Configuration Guide. |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite or remote |
Security Level |
Provisioning or higher |
Step 1 | In node view (single-shelf mode) or shelf view (multishelf view), double-click the line card where you want to delete PPM settings. |
Step 2 | Verify that the PPM port Service State is OOS,DSBLD. If it is not OOS,DSBLD, follow the tasks in "NTP-G128 Manage Pluggable Port Modules" in the chapter "Provision Transponder and Muxponder Cards" of Cisco ONS 15454 DWDM Configuration Guide to change the Service State of the PPM port to OOS,DSBLD. |
Step 3 | Click the Provisioning > Pluggable Port Modules tabs. |
Step 4 |
To delete a PPM and the associated ports, perform the following:
|
Step 5 |
Verify that the PPM provisioning is deleted:
|
Step 6 | (Optional) If you need to remove the PPM hardware, complete the DLP-G728 Remove PPM from the Line Card. |
Step 7 | Return to your originating procedure (NTP). |
Purpose |
This task removes PPMs from the line cards. |
Tools/Equipment |
|
Prerequisite Procedures |
None |
Required/As Needed |
As needed |
Onsite/Remote |
Onsite |
Security Level |
Provisioning or higher |
Warning |
GBICs, SFP, SFP+, XFP, CXP, and CFPSFP, SFP+, and XFP modules are Class I laser products. Statement 1008 |
Warning |
Because invisible laser radiation may be emitted from the aperture of the port when no cable is connected, avoid exposure to laser radiation and do not stare into open apertures. Statement 70 |
Warning |
Ultimate disposal of this product should be handled according to all national laws and regulations. Statement 1040 |
Note |
|
Step 1 | Disconnect the network fiber cable from the PPM connector. If the GBICs, SFP, SFP+, XFP, CXP, and CFPSFP, SFP+, and XFP connector has a latch securing the fiber cable, pull it upward to release the cable. | ||
Step 2 |
Remove PPM. Perform the following as necessary:
|
||
Step 3 | Remove GBIC with clips. Perform the following: | ||
Step 4 | Remove GBIC with a handle. Perform the following: | ||
Step 5 |
Remove SFP, SFP+, or XFPSFP, SFP+, or XFP module. Perform the following:
|
||
Step 6 |
Remove CFP module. Perform the following:
|
||
Step 7 | Return to your originating procedure (NTP). |
Use this document in conjunction with the following referenced publications as needed:
Cisco ONS 15454 DWDM Configuration Guide
Cisco ONS 15454 DWDM Procedure Guide
Cisco ONS 15454 DWDM Reference Manual
Cisco ONS 15454 DWDM Troubleshooting Guide
Cisco ONS 15454 Procedure Guide
Cisco ONS 15454 Reference Manual
Cisco ONS 15454 Troubleshooting Guide
Cisco ONS 15454 SDH Procedure Guide
Cisco ONS 15454 SDH Reference Manual
Cisco ONS 15454 SDH Troubleshooting Guide
Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide
Cisco ONS 15310-CL and Cisco ONS 15310-MA Reference Manual
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide
Cisco ONS 15310-MA SDH Procedure Guide
Cisco ONS 15310-MA SDH Reference Manual
Cisco ONS 15310-MA SDH Troubleshooting Guide
Cisco ONS 15600 Procedure Guide
Cisco ONS 15600 Reference Manual
Cisco ONS 15600 Troubleshooting Guide
Cisco ONS 15600 SDH Procedure Guide
Cisco ONS 15600 SDH Reference Manual
Cisco ONS 15600 SDH Troubleshooting Guide
Regulatory Compliance and Safety Information for Cisco CPT and Cisco ONS Platforms
For information on obtaining documentation, using the Cisco Bug Search Tool (BST), submitting a service request, and gathering additional information, see What's New in Cisco Product Documentation, at: http://www.cisco.com/c/en/us/td/docs/general/whatsnew/whatsnew.html.
Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical documentation as an RSS feed and delivers content directly to your desktop using a reader application. The RSS feeds are a free service.
Copyright © 2015, Cisco Systems, Inc. All rights reserved.