The show interface command is invoked from the EXEC mode and displays VSAN trunking configurations for a TE port. Without any arguments, this command displays the information for all of the configured interfaces in the switch.
The following example shows how to display the trunk mode of a Fibre Channel interface:
switch# show interface fc3/3
fc3/3 is up
Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)
Port WWN is 20:83:00:0d:ec:6d:78:40
Peer port WWN is 20:0c:00:0d:ec:0d:d0:00
Admin port mode is auto, trunk mode is on
...
The following example shows how to display the trunk protocol of a Fibre Channel interface:
switch# show trunk protocol
Trunk protocol is enabled
The following example shows how to display the VSAN information for all trunk interfaces:
switch# show interface trunk vsan 1-1000
fc3/1 is not trunking
...
fc3/11 is trunking
Belongs to san-port-channel 6
Vsan 1 is up, FCID is 0xef0000
Vsan 2 is up, FCID is 0xef0000
...
san-port-channel 6 is trunking
Vsan 1 is up, FCID is 0xef0000
Vsan 2 is up, FCID is 0xef0000