Show Commands
This chapter describes the Cisco NX-OS Fibre Channel, virtual Fibre Channel, and Fibre Channel over Ethernet (FCoE) show commands.
show cfs
To display Cisco Fabric Services (CFS) information, use the show cfs command.
show cfs { application [ name app-name ] | lock [ name app-name [ vsan vsan-id ]] | merge status [ name app-name [ vsan vsan-id ]] | peers [ name app-name [ vsan vsan-id ]] | regions | status }
Syntax Description
application |
Displays locally registered applications. |
name app-name |
(Optional) Specifies a local application information by name. The name can be a maximum of 64 characters. |
lock |
Displays the state of application logical or physical locks. |
vsan vsan-id |
(Optional) Specifies the VSAN ID. The range is from 1 to 4093. |
merge status |
Displays CFS merge information. |
peers |
Displays logical or physical CFS peers. |
regions |
Displays the CFS regions. |
status |
Displays if CFS distribution is enabled or disabled. Enabled is the default configuration. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The show cfs application command displays only those applications that are registered with CFS. Conditional services that use CFS do not appear in the output unless those services are running.
Examples
This example shows how to display the CFS physical peer information for all applications:
This example shows how to display the CFS information for all applications on the switch:
switch# show cfs application
This example shows how to display the status of the CFS distribution:
Related Commands
|
|
cfs |
Configures Cisco Fabric Services (CFS) information. |
show debug npv
To display the N Port Virtualization (NPV) debug commands configured on the switch, use the show debug npv command.
show debug npv
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The show debug npv command is available only when the switch is in NPV mode.
Examples
This example shows how to display all the NPV debug commands available on the switch:
Related Commands
|
|
debug npv |
Enables the debugging of NPV configurations. |
show device-alias
To display the device name information, use the show device-alias command.
show device-alias { database | merge status | name device-name [ pending ] | pending | pending-diff | pwwn pwwn-id [ pending ] | session status | statistics | status }
Syntax Description
database |
Displays the entire device name database. |
merge status |
Displays the device merge status. |
name device-name |
Displays device name database information for a specific device name. |
pending |
(Optional) Displays the pending device name database information. |
pending-diff |
Displays pending differences in the device name database information. |
pwwn pwwn-id |
Displays device name database information for a specific pWWN. The format is hh : hh : hh : hh : hh : hh : hh : hh, where h is a hexadecimal digit. |
session status |
Displays the device name session status. |
statistics |
Displays device name database statistics. |
status |
Displays the device name database status. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
To use fcaliases as device names instead of using the cryptic device name, add only one member per fcalias.
Examples
This example shows how to display the contents of the device alias database:
switch# show device-alias database
This example shows how to display all global fcaliases and all Virtual SAN (VSAN) dependent fcaliases:
switch# show device-alias name efg
This example shows how to display all global fcaliases and all VSAN dependent fcaliases:
switch# show device-alias statistics
Related Commands
|
|
device-alias name |
Configures device alias names. |
device-alias database |
Configures device alias information. |
device-alias distribute |
Enables device alias CFS distribution. |
show fabric-binding
To display configured fabric binding information, use the show fabric-binding command.
show fabric-binding { database [ active ] [ vsan vsan-id ] | efmd statistics [ vsan vsan-id ] | statistics [ vsan vsan-id ] | status [ vsan vsan-id ] | violations [ last number ]}
Syntax Description
database |
Displays configured database information. |
active |
(Optional) Displays the active database configuration information. |
vsan vsan-id |
(Optional) Specifies the FICON-enabled Virtual SAN (VSAN) ID. The range is from 1 to 4093. |
efmd statistics |
Displays Exchange Fabric Membership Data (EFMD) statistics. |
statistics |
Displays fabric binding statistics. |
status |
Displays fabric binding status. |
violations |
Displays violations in the fabric binding configuration. |
last number |
(Optional) Specifies recent violations. The range is from 1 to 100. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the configured fabric binding database information:
switch# show fabric-binding database
This example shows how to display the active fabric binding information:
switch# show fabric-binding database active
This example shows how to display the active VSAN-specific fabric binding information:
switch# show fabric-binding database active vsan 61
This example shows how to display the configured VSAN-specific fabric binding information:
switch# show fabric-binding database vsan 4
This example shows how to display the fabric binding statistics:
switch# show fabric-binding statistics
This example shows how to display the fabric binding status for each VSAN:
switch# show fabric-binding status
This example shows how to display the EFMD statistics:
switch# show fabric-binding efmd statistics
This example shows how to display the EFMD statistics for a specified VSAN:
switch# show fabric-binding efmd statistics vsan 4
This example shows how to display the fabric binding violations:
switch# show fabric-binding violations
Related Commands
|
|
fabric-binding |
Configures fabric binding in a VSAN. |
show fc2
To display FC2 information, use the show fc2 command.
show fc2 { bind | classf | exchange | exchresp | flogi | nport | plogi | plogi_pwwn | port [ brief ] | socket | sockexch | socknotify | socknport | vsan }
Syntax Description
bind |
Displays FC2 socket bindings. |
classf |
Displays FC2 classf sessions. |
exchange |
Displays FC2 active exchanges. |
exchresp |
Displays FC2 active responder exchanges. |
flogi |
Displays FC2 FLOGI table. |
nport |
Displays FC2 local N ports. |
plogi |
Displays FC2 PLOGI sessions. |
plogi_pwwn |
Displays FC2 PLOGI pWWN entries. |
port |
Displays FC2 physical port table. |
brief |
(Optional) Displays FC2 physical port table in a brief format. |
socket |
Displays FC2 active sockets. |
sockexch |
Displays FC2 active exchanges for each socket. |
socknotify |
Displays FC2 local N port PLOGI/LOGO notifications for each socket. |
socknport |
Displays FC2 local nports per each socket. |
vsan |
Displays the FC2 VSAN table. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the FC2 active socket information:
This example shows how to display the FC2 socket binding information:
This example shows how to display the FC2 local N port information:
This example shows how to display the FC2 PLOGI session information:
This example shows how to display the FC2 physical port information:
This example shows how to display the FC2 local N port PLOGI notifications for each socket:
switch# show fc2 socknotify
This example shows how to display the FC2 local N ports for each socket:
switch# show fc2 socknport
This example shows how to display the FC2 VSAN table:
show fc-port-security
To display configured port security feature information, use the show fc-port-security command.
show fc-port-security { database [ active [ vsan vsan-id ]] | fwwn fwwn-id vsan vsan-id | interface { fc slot / port | san-port-channel port } vsan vsan-id | vsan vsan-id | pending [ vsan vsan-id ] | pending-diff [ vsan vsan-id ] | session status [ vsan vsan-id ] | statistics [ vsan vsan-id ] | status [ vsan vsan-id ] | violations [ last count | vsan vsan-id ]}
Syntax Description
database |
Displays database-related port security information. |
active |
(Optional) Displays the activated database information. |
vsan vsan-id |
(Optional) Displays information for the specified database. |
fwwn fwwn-id |
Displays information for the specified fabric WWN. |
interface |
Displays information for an interface. |
fc slot / port |
Displays information for the specified Fibre Channel interface. |
san-port-channel port |
Displays information for the specified SAN port channel interface. The range is from 1 to 128. |
pending |
Displays the server address pending configuration. |
pending-diff |
Displays the server address pending configuration differences with the active configuration. |
session status |
Displays the port security session status on a per VSAN basis. |
statistics |
Displays port security statistics. |
status |
Displays the port security status on a per VSAN basis. |
violations |
Displays violations in the port security database. |
last count |
(Optional) Displays the last number of lines in the database. The range is from 1 to 100. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The access information for each port can be individually displayed. If you specify the fabric world wide name (fWWN) or interface options, all devices that are paired in the active database (at that point) with the given fWWN or the interface are displayed.
When you enter the show fc-port-security command with the last number option, only the specified number of entries that appear first are displayed.
Examples
This example shows how to display the contents of the port security database:
switch# show fc-port-security database
This example shows how to display the output of the active port security database in VSAN 1:
switch# show fc-port-security database vsan 1
This example shows how to display the active database:
switch# show fc-port-security database active
This example shows how to display the wildcard fWWN port security in VSAN 1:
switch# show fc-port-security database fwwn 20:85:00:44:22:00:4a:9e vsan 1
This example shows how to display the configured fWWN port security in VSAN 1:
switch# show fc-port-security database fwwn 20:01:00:05:30:00:95:de vsan 1
This example shows how to display the interface port information in VSAN 2:
switch# show fc-port-security database interface fc 2/1 vsan 2
This example shows how to display the port security statistics:
switch# show fc-port-security statistics
This example shows how to display the status of the active database and the autolearn configuration:
switch# show fc-port-security status
This example shows how to display the previous 100 violations:
switch# show fc-port-security violations
Related Commands
|
|
fc-port-security |
Configures port security parameters. |
show fcalias
To display the member name information in a Fibre Channel alias (fcalias), use the show fcalias command.
show fcalias [ name fcalias-name ] [ pending ] [ vsan vsan-id ]
Syntax Description
name fcalias-name |
(Optional) Displays fcalias information for a specific name. The maximum length is 64. |
pending |
(Optional) Displays pending fcalias information. |
vsan vsan-id |
(Optional) Displays fcalias information for a VSAN. The range is from 1 to 4093. |
Command Default
Displays a list of all global fcaliases and all VSAN-dependent fcaliases.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
To make use of fcaliases as device names instead of using the cryptic device name, add only one member per fcalias.
Examples
This example shows how to display the fcalias configuration information:
switch# show fcalias vsan 1
Related Commands
|
|
fcalias name |
Configures fcalias names. |
show fcdomain
To display the Fibre Channel domain (fcdomain) information, use the show fcdomain command.
show fcdomain [ address-allocation [ cache ] | allowed | domain-list | fcid persistent [ unused ] | pending [ vsan vsan-id ] | pending-diff [ vsan vsan-id ] | session-status [ vsan vsan-id ] | statistics [ interface { fc slot / port [ vsan vsan-id ] } | san-port-channel port [ vsan vsan-id ] ] | status | vsan vsan-id ]
Syntax Description
address-allocation |
(Optional) Displays statistics for the FC ID allocation. |
cache |
(Optional) Reassigns the FC IDs for a device (disk or host) that exited and reentered the fabric for the principal switch. In the cache content, Virtual SAN (VSAN) refers to the VSAN that contains the device, WWN refers to the device that owned the FC IDs, and mask refers to a single or entire area of FC IDs. |
allowed |
(Optional) Displays a list of allowed domain IDs. |
domain-list |
(Optional) Displays a list of domain IDs provided by the principal switch. |
fcid persistent |
(Optional) Displays persistent FC IDs (across reboot). |
unused |
(Optional) Displays unused persistent FCIDs (across reboot). |
pending |
(Optional) Displays the pending configuration. |
vsan vsan-id |
(Optional) Specifies a VSAN ID. The range is from 1 to 4093. |
pending-diff |
(Optional) Displays the difference between the running configuration and the pending configuration. |
session-status |
(Optional) Displays the last action performed by an FC domain. |
statistics |
(Optional) Displays the statistics of an FC domain. |
interface |
(Optional) Specifies an interface. |
fc slot / port |
(Optional) Specifies a Fibre Channel interface. |
san-port-channel port |
(Optional) Specifies a SAN port channel interface. The range is from 1 to 128. |
status |
(Optional) Displays all VSAN-independent information in an FC domain. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
When you enter the show fcdomain with no arguments, all VSANs appear. The VSANs should be active or you will get an error.
Examples
This example shows how to display the fcdomain information for VSAN 1:
switch# show fcdomain vsan 1
This example shows how to display the fcdomain domain-list information for VSAN 76:
switch# show fcdomain domain-list vsan 76
--------- -----------------------
0xc8(200) 20:01:00:05:30:00:47:df [Principal]
0x63(99) 20:01:00:0d:ec:08:60:c1 [Local]
0x61(97) 50:00:53:0f:ff:f0:10:06 [Virtual (IVR)]
Table 1 describes the significant fields shown in the show fcdomain domain-list command output.
Table 1 show fcdomain Field Descriptions
|
|
Domain ID |
Lists the domain IDs corresponding to the WWN. |
WWN |
Indicates the WWN of the switch (physical or virtual) that requested the corresponding domain ID. |
Principal |
Indicates which row of the display lists the WWN and domain ID of the principal switch in the VSAN. |
Local |
Indicates which row of the display lists the WWN and domain ID of the local switch (the switch where you entered the show fcdomain domain-list command). |
Virtual (IVR) |
Indicates which row of the display lists the WWN of the virtual switch used by the Inter-VSAN Routing (IVR) manager to obtain the domain ID. |
This example shows how to display the allowed domain ID lists:
switch# show fcdomain allowed vsan 1
This example shows how to display the status of the CFS distribution for allowed domain ID lists:
switch# show fcdomain status
This example shows how to display the pending configuration changes:
switch# show fcdomain pending vsan 10
This example shows how to display the differences between the pending configuration and the current configuration:
switch# show fcdomain pending-diff vsan 10
This example shows how to display the status of the distribution session:
switch# show fcdomain session-status vsan 1
Related Commands
|
|
fcdomain |
Configures the Fibre Channel domain feature. |
show fcdroplatency
To display the configured Fibre Channel latency parameters, use the show fcdroplatency command.
show fcdroplatency [ network | switch ]
Syntax Description
network |
(Optional) Displays the network latency in milliseconds. |
switch |
(Optional) Displays the switch latency in milliseconds. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the configured Fibre Channel latency parameters:
switch# show fcdroplatency
Related Commands
|
|
fcdroplatency |
Configures the network and switch Fibre Channel drop latency time. |
show fcflow stats
To display the configured Fibre Channel flow (fcflow) information, use the show fcflow stats command.
show fcflow stats [ aggregated | usage ] [ index flow-index ]
Syntax Description
aggregated |
(Optional) Displays aggregated fcflow statistics. |
usage |
(Optional) Displays flow index usage. |
index flow-index |
(Optional) Specifies an fcflow index. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the aggregated fcflow details:
switch# show fcflow stats aggregated
This example shows how to display the fcflow details:
switch# show fcflow stats
This example shows how to display the fcflow index usage:
switch# show fcflow stats usage
Related Commands
|
|
fcflow stats |
Configures fcflow statistics. |
show fcid-allocation
To display the Fibre Channel area list of company IDs, use the show fcid allocation command.
show fcid-allocation area | company-id-from-wwn wwn [ company-id ]
Syntax Description
area |
Displays the auto area list of company IDs. |
company-id-from-wwn wwn |
Displays the company ID from the specified world wide name (WWN). |
company-id |
(Optional) Company ID (also know as Organizational Unit Identifier, or OUI) to display. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the Fibre Channel area company list of company IDs:
switch# show fcid-allocation area
Fcid area allocation company id info:
+ - Additional user configured company ids.
* - Explicitly deleted company ids from default list.
Table 2 describes the significant fields shown in the display.
Table 2 show fcid-allocation area company Field Descriptions
|
|
+ |
Indicates a company ID added to the default list. |
– |
Indicates a company ID deleted from the default list. |
Related Commands
|
|
fcid-allocation |
Adds a FCID to the default area company ID list. |
show fcns database
To display the results of the discovery, or to display the name server database for a specified Virtual SAN (VSAN) or for all VSANs, use the show fcns database command.
show fcns database { detail [ vsan vsan-id ] | domain domain-id [ detail ] [ vsan vsan-range ] | fcid fcid-id [ detail ] vsan vsan-range | local [ detail ] [ vsan vsan-range ] | vsan vsan-id }
Syntax Description
detail |
Displays all objects in each entry. |
vsan vsan-id |
(Optional) Displays entries for a specified VSAN ID. The range is from 1 to 4093. |
domain domain-id |
Displays entries in a domain. |
detail |
(Optional) Displays detailed entries for the domain. |
fcid fcid-id |
Displays entry for the given port. |
local |
Displays local entries. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The discovery can take several minutes to complete, especially if the fabric is large or if several devices are slow to respond.
Virtual enclosure ports can be viewed using the show fcns database command.
Examples
This example shows how to display the contents of the FCNS database:
switch# show fcns database
This example shows how to display the detailed contents of the FCNS database:
switch# show fcns database detail
This example shows how to display the management VSAN (VSAN 2):
switch# show fcns database vsan 2
This example shows how to display the database for all configured VSANs:
switch# show fcns database
Related Commands
|
|
fcns |
Specifies the configuration mode command for name server configuration. |
show fcns statistics
To display the statistical information for a specified Virtual SAN (VSAN) or for all VSANs, use the show fcns statistics command.
show fcns statistics [ detail ] [ vsan vsan-id ]
Syntax Description
detail |
(Optional) Displays detailed statistics. |
vsan vsan-id |
(Optional) Displays statistics for the specified VSAN ID. The range is from 1 to 4093. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the statistical information for a specified VSAN:
switch# show fcns statistics
Related Commands
|
|
fcns |
Specifies the configuration mode command for name server configuration. |
show fcoe
To display the status of Fibre Channel over Ethernet (FCoE) parameters on the switch, use the show fcoe command.
show fcoe
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the FCoE status:
FCF-MAC is 00:0d:ec:a3:9d:80
FKA Advertisement period for FCF is 8 seconds
Related Commands
|
|
fcoe fcf-priority |
Configures the FCoE Initialization Protocol (FIP) priority value. |
fcoe fcmap |
Configures the FCoE MAC Address Prefix (FC MAP) used to associate the FCoE node (ENode). |
fcoe fka-adv-period |
Configures the time interval at which FIP keep alive (FKA) messages are transmitted to the MAC address of the ENode. |
show fcoe database |
Displays the FCoE database information. |
show fcoe-npv issu-impact
To display the configuration issues caused by the Fibre Channel over Ethernet (FCoE) N-Port Virtualizer (NPV) during a nondisruptive in-service software upgrade (ISSU), use the show fcoe-npv issu-impact command.
show fcoe-npv issu-impact
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(3)N2(1) |
This command was introduced. |
Usage Guidelines
Before you use this command, make sure that you enable Fibre Channel over Ethernet (FCoE) N-Port Virtualizer (NPV) on the switch by using the feature fcoe-npv command.
This command requires the FCoE NPV license.
Examples
This example shows how to display the configuration issues caused by the FCoE NPV feature:
switch# show fcoe-npv issu-impact
show fcoe-npv issu-impact
-------------------------
Please make sure to enable "disable-fka" on all logged in VFCs
Please increase the FKA duration to 60 seconds on FCF
Active VNP ports with no disable-fka set
----------------------------------------
ISSU downgrade not supported as feature fcoe-npv is enabled
Related Commands
|
|
feature fcoe-npv |
Enables FCoE NPV on the switch. |
show running-config fcoe_mgr |
Displays the FCoE running configuration information. |
show tech-support fcoe |
Displays troubleshooting information about FCoE. |
show fcoe database
To display information about the Fibre Channel over Ethernet (FCoE) database, use the show fcoe database command.
show fcoe database
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the FCoE database:
switch# show fcoe database
-------------------------------------------------------------------------------
INTERFACE FCID PORT NAME MAC ADDRESS
-------------------------------------------------------------------------------
vfc1 0x580016 10:00:00:00:07:f8:0e:45 00:00:00:13:05:01
vfc1 0x580017 10:00:00:00:07:f8:21:bf 00:00:00:13:05:01
vfc2 0x580020 10:00:00:00:07:f8:0e:46 00:00:00:13:05:02
vfc2 0x580033 10:00:00:00:07:f8:21:c0 00:00:00:13:05:02
vfc4 0x58001e 10:00:00:00:07:f8:0e:48 00:00:00:13:05:04
vfc4 0x580031 10:00:00:00:07:f8:21:c2 00:00:00:13:05:04
vfc5 0x58001d 10:00:00:00:07:f8:0e:49 00:00:00:13:05:05
vfc5 0x580030 10:00:00:00:07:f8:21:c3 00:00:00:13:05:05
vfc6 0x58001c 10:00:00:00:07:f8:0e:4a 00:00:00:13:05:06
vfc6 0x58002f 10:00:00:00:07:f8:21:c4 00:00:00:13:05:06
vfc7 0x58001b 10:00:00:00:07:f8:0e:4b 00:00:00:13:05:07
vfc7 0x58002e 10:00:00:00:07:f8:21:c5 00:00:00:13:05:07
vfc8 0x58001a 10:00:00:00:07:f8:0e:4c 00:00:00:13:05:08
vfc8 0x58002d 10:00:00:00:07:f8:21:c6 00:00:00:13:05:08
vfc9 0x580019 10:00:00:00:07:f8:0e:4d 00:00:00:13:05:09
vfc9 0x58002c 10:00:00:00:07:f8:21:c7 00:00:00:13:05:09
vfc10 0x580018 10:00:00:00:07:f8:0e:4e 00:00:00:13:05:0a
vfc10 0x58002a 10:00:00:00:07:f8:21:c8 00:00:00:13:05:0a
vfc11 0x580023 10:00:00:00:07:f8:0e:4f 00:00:00:13:05:0b
vfc11 0x580036 10:00:00:00:07:f8:21:c9 00:00:00:13:05:0b
vfc12 0x580022 10:00:00:00:07:f8:0e:50 00:00:00:13:05:0c
vfc12 0x580035 10:00:00:00:07:f8:21:ca 00:00:00:13:05:0c
vfc13 0x580021 10:00:00:00:07:f8:0e:51 00:00:00:13:05:0d
vfc13 0x580034 10:00:00:00:07:f8:21:cb 00:00:00:13:05:0d
vfc14 0x58002b 10:00:00:00:07:f8:0e:52 00:00:00:13:05:0e
vfc14 0x58003d 10:00:00:00:07:f8:21:cc 00:00:00:13:05:0e
vfc15 0x580029 10:00:00:00:07:f8:0e:53 00:00:00:13:05:0f
vfc15 0x58003c 10:00:00:00:07:f8:21:cd 00:00:00:13:05:0f
vfc16 0x580028 10:00:00:00:07:f8:0e:54 00:00:00:13:05:10
vfc16 0x58003b 10:00:00:00:07:f8:21:ce 00:00:00:13:05:10
vfc17 0x580027 10:00:00:00:07:f8:0e:55 00:00:00:13:05:11
vfc17 0x580039 10:00:00:00:07:f8:21:cf 00:00:00:13:05:11
vfc18 0x580026 10:00:00:00:07:f8:0e:56 00:00:00:13:05:12
vfc18 0x58003a 10:00:00:00:07:f8:21:d0 00:00:00:13:05:12
vfc19 0x580025 10:00:00:00:07:f8:0e:57 00:00:00:13:05:13
vfc19 0x580038 10:00:00:00:07:f8:21:d1 00:00:00:13:05:13
vfc20 0x580024 10:00:00:00:07:f8:0e:58 00:00:00:13:05:14
Related Commands
|
|
fcoe fcf-priority |
Configures the FCoE Initialization Protocol (FIP) priority value. |
fcoe fcmap |
Configures the FCoE MAC Address Prefix (FC MAP) used to associate the FCoE node (ENode). |
fcoe fka-adv-period |
Configures the time interval at which FIP keep alive (FKA) messages are transmitted to the MAC address of the ENode. |
show fcoe |
Displays the status of the FCoE parameters. |
show fcroute
To view specific information about existing Fibre Channel and Fabric Shortest Path First (FSPF) configurations, use the show fcroute command.
show fcroute { distance | label [ label ] vsan vsan-id | multicast [ fc-id vsan vsan-id | vsan vsan-id ] | summary [ vsan vsan-id ] | unicast [[ host ] fc-id fc-mask vsan vsan-id | vsan vsan-id ]}
Syntax Description
distance |
Displays the FC route preference. |
label |
Displays label routes. |
label |
(Optional) Label routes for the specified label. |
vsan vsan-id |
(Optional) Specifies the ID of the VSAN (from 1 to 4093). |
multicast |
Displays FC multicast routes. |
fc-id |
(Optional) Fibre Channel ID. |
summary |
Displays the FC routes summary. |
unicast |
Displays FC unicast routes. |
host |
Unicast routes for the specified host. |
fc-mask |
Unicast routes for hosts that match the range of FCIDs that are specified by the mask. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
When the number of routes are displayed in the command output, both visible and hidden routes are included in the total number of routes.
Examples
This example shows how to display the administrative distance:
switch# show fcroute distance
This example shows how to display the multicast routing information:
switch# show fcroute multicast
This example shows how to display the FCID information for a specified VSAN:
switch# show fcroute multicast vsan 3
This example shows how to display the FCID and interface information for a specified VSAN:
switch# show fcroute multicast 0xffffff vsan 2
This example shows how to display the unicast routing information:
switch# show fcroute unicast
This example shows how to display the unicast routing information for a specified VSAN:
switch# show fcroute unicast vsan 4
This example shows how to display the unicast routing information for a specified FCID:
switch# show fcroute unicast 0x040101 0xffffff vsan 4
This example shows how to display the route database information:
switch# show fcroute summary
This example shows how to display the route database information for a specified VSAN:
switch# show fcroute summary vsan 4
Related Commands
|
|
fcroute |
Configures Fibre Channel routes and activates policy routing. |
show fcs
To display the status of the fabric configuration, use the show fcs commands.
show fcs { database [ vsan vsan-id ] | ie [ nwwn wwn | vsan vsan-id ] | platform { name string | vsan vsan-id } | port { pwwn wwn | vsan vsan-id } | statistics vsan vsan-id | vsan }
Syntax Description
database |
Displays local database of frame check sequence (FCS). |
vsan vsan-id |
(Optional) Specifies a Virtual SAN (VSAN) ID. The range is from 1 to 4093. |
ie |
Displays interconnect element objects information. |
nwwn wwn |
(Optional) Specifies a node WWN ID. The format is hh : hh : hh : hh : hh : hh : hh : hh. |
platform |
Displays platform objects information. |
name string |
(Optional) Specifies a platform name. The name can be a maximum of 255 characters. |
port |
Displays port objects information. |
pwwn wwn |
Specifies a port WWN ID. The format is hh : hh : hh : hh : hh : hh : hh : hh. |
statistics |
Displays statistics for FCS packets. |
vsan |
Displays list of all the VSANs. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the FCS database information:
switch# show fcs database
This example shows how to display the interconnect element object information for a specific VSAN:
switch# show fcs ie vsan 1
This example shows how to display the interconnect element object information for a specific WWN:
switch# show fcs ie nwwn 20:01:00:05:30:00:16:df vsan 1
This example shows how to display the platform information:
switch# show fcs platform name SamplePlatform vsan 1
This example shows how display to the platform information within a specified VSAN:
switch# show fcs platform vsan 1
This example shows how to display the FCS port information within a specified VSAN:
switch# show fcs port vsan 24
This example shows how to display the ports within a specified WWN:
switch# show fcs port pwwn 20:51:00:05:30:00:16:de vsan 24
This example shows how to display the FCS statistics:
switch# show fcs statistics
Related Commands
|
|
fcs |
Configures FCS platform attributes. |
show fcsp
To display the status of the Fibre Channel Security Protocol (FC-SP) configuration, use the show fcsp commands.
show fcsp [ asciiwwn ascii-wwn | dhchap [ database ] | interface { fc slot / port | vfc vfc-id } [ statistics | wwn ]]
Syntax Description
asciiwwn ascii-wwn |
(Optional) Displays the ASCII representation of the WWN used with authentication, authorization, and accounting (AAA) server. |
dhchap |
(Optional) Displays the DHCHAP hash algorithm status. |
database |
(Optional) Displays the contents of the local DHCHAP database. |
interface |
(Optional) Displays the FC-SP settings for a Fibre Channel or Fibre Channel interface. |
fc slot / port |
Specifies a Fibre Channel interface. |
vfc vfc-id |
(Optional) Specifies a virtual Fibre Channel interface. |
statistics |
(Optional) Displays the statistics for the specified interface. |
wwn |
(Optional) Displays the FC-SP identity of the other device. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the DHCHAP configurations in FC interfaces:
switch# show fcsp interface fc2/3
This example shows how to display the DHCHAP statistics for an FC interface:
switch# show fcsp interface fc2/3 statistics
This example shows how to display the FC-SP WWN of the device connected through a specified interface:
switch# show fcsp interface fc 2/1 wwn
This example shows how to display the hash algorithm and DHCHAP groups configured for the local switch:
This example shows how to display the DHCHAP local password database:
switch# show fcsp dhchap database
This example shows how to display the ASCII representation of the device WWN:
switch# show fcsp asciiwwn 30:11:bb:cc:dd:33:11:22
Related Commands
|
|
fcsp enable |
Enables the FC-SP feature for this switch. |
show fctimer
To display the Fibre Channel timers (fctimer), use the show fctimer command.
show fctimer [ d_s_tov [ vsan vsan-id ] | e_d_tov [ vsan vsan-id ] | f_s_tov [ vsan vsan-id ] | r_a_tov [ vsan vsan-id ] | last action status | pending | pending-diff | session status | status | vsan vsan-id ]
Syntax Description
d_s_tov |
(Optional) Displays the distributed services time out value (D_S_TOV) in milliseconds. |
vsan vsan-id |
(Optional) Displays information for a Virtual SAN (VSAN). The range is from 1 to 4093. |
e_d_tov |
(Optional) Displays the error detection timeout value (E_D_TOV) in milliseconds. |
f_s_tov |
(Optional) Displays the fabric stability timeout value (F_S_TOV) in milliseconds. |
r_a_tov |
(Optional) Displays the resource allocation time out value (R_A_TOV) in milliseconds. |
last action status |
(Optional) Displays the status of the last Cisco Fabric Services (CFS) commit or discard operation. |
pending |
(Optional) Displays the status of pending fctimer commands. |
pending-diff |
(Optional) Displays the difference between the pending database and running configuration. |
session status |
(Optional) Displays the state of the fctimer CFS session. |
status |
(Optional) Displays the Fibre Channel timer status. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the configured global TOVs:
This example shows how to display the configured TOVs for a specified VSAN:
switch# show fctimer vsan 10
Related Commands
|
|
fctimer |
Configures fctimer parameters. |
show fdmi
To display the Fabric-Device Management Interface (FDMI) database information, use the show fdmi command.
show fdmi database [ detail [ hba-id { hba-id vsan vsan-id } | vsan vsan-id ] | vsan vsan-id ] | suppress-updates
Syntax Description
database |
Displays the FDMI database contents. |
detail |
(Optional) Specifies detailed FDMI information. |
hba-id hba-id |
(Optional) Displays detailed information for the specified host bus adapter (HBA) entry. |
vsan vsan-id |
(Optional) Specifies FDMI information for the specified Virtual SAN (VSAN). The range is from 1 to 4093. |
suppress-updates |
Displays the VSANs that are configured to suppress updates. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display all HBA management servers:
switch# show fdmi database
This example shows how to display the VSAN1-specific FDMI information:
switch# show fdmi database detail vsan 1
This example shows how to display the details for the specified HBA entry:
switch# show fdmi database detail Hba-id 21:01:00:e0:8b:2a:f6:54 vsan 1
Related Commands
|
|
fdmi suppress-updates |
Suppresses FDMI updates. |
show fex
To display information about a specific Fabric Extender or all attached chassis, use the show fex command.
show fex [ chassis_ID [ detail ]]
Syntax Description
chassis_ID |
(Optional) Fabric Extender chassis ID. The chassis ID range is from 100 to 199. |
detail |
(Optional) Displays a detailed listing. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display information about all attached Fabric Extender chassis:
Number Description State Model Serial
------------------------------------------------------------------------
100 FEX0100 Online N5K-C5110T-BF-1GE JAF1237ABSE
101 FEX0101 Online N2K-C2248TP-1GE JAF11223333
102 FEX0102 Online N5K-C5110T-BF-1GE JAF1241BLHQ
105 FEX0105 Online N2K-C2232P-10GE JAF1331AKBM
This example shows how to display information about a specific Fabric Extender chassis:
FEX: 101 Description: FEX0101 state: Online
FEX version: 4.2(1)N1(1) [Switch version: 4.2(1)N1(1)]
Extender Model: N2K-C2248TP-1GE, Extender Serial: JAF11223333
pinning-mode: static Max-links: 1
Fabric port for control traffic: Eth3/5
Po5 - Interface Up. State: Active
Eth3/5 - Interface Up. State: Active
Eth3/6 - Interface Up. State: Active
Related Commands
|
|
fex |
Creates a Fabric Extender and enters fabric extender configuration mode. |
show flogi
To list all the fabric login (FLOGI) sessions through all interfaces across all Virtual SAN (VSANs), use the show flogi command.
show flogi { auto-area-list } | database { fcid fcid-id | interface { fc slot / port | vfc vfc-id } | vsan vsan-id }
Syntax Description
auto-area-list |
Displays the list of Organizational Unit Identifiers (OUIs) that are allocated areas. |
database |
Displays information about FLOGI sessions. |
fcid fcid-id |
Displays FLOGI database entries based on the FCID allocated. The format is 0xhhhhhh. |
interface |
Displays FLOGI database entries based on the logged in interface. |
fc slot / port |
Specifies the Fibre Channel or virtual Fibre Channel interface by slot and port number. |
vfc vfc-id |
Specifies a virtual Fibre Channel interface. |
vsan vsan-id |
Displays FLOGI database entries based on the VSAN ID. The range is from 1 to 4093. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The output of this command is sorted by interface numbers and then by VSAN IDs.
In a Fibre Channel fabric, each host or disk requires an FCID. Use the show flogi database command to verify if a storage device is displayed in the fabric login (FLOGI) table as in the examples below. If the required device is displayed in the FLOGI table, the fabric login is successful. Examine the FLOGI database on a switch that is directly connected to the host HBA and connected ports.
Examples
This example shows how to display the details on the FLOGI database:
switch# show flogi database
This example shows how to display the FLOGI interface:
switch# show flogi database interface fc 2/3
This example shows how to display the FLOGI VSAN:
switch# show flogi database vsan 1
This example shows how to display the FLOGI for a specific FCID:
switch# show flogi database fcid 0xef02e2
Related Commands
|
|
show fcns database |
Displays all the local and remote name server entries. |
show fspf
To display global Fibre Shortest Path First (FSPF) routing information, use the show fspf command.
show fspf [ database [ vsan vsan-id ] [ detail | domain domain-id detail ] | interface | vsan vsan-id interface { fc slot / port | san-port-channel port-channel }]
Syntax Description
database |
(Optional) Displays the FSPF link state database. |
vsan vsan-id |
(Optional) Specifies the Virtual SAN (VSAN) ID. The range is from 1 to 4093. |
detail |
(Optional) Displays detailed FSPF information. |
domain domain-id |
(Optional) Specifies the domain of the database. The range is from 0 to 255. |
interface |
(Optional) Specifies the FSPF interface. |
fc slot / port |
Specifies the Fibre Channel interface to configure. |
san-port-channel port-channel |
Specifies the port channel interface. The range is from 1 to 256. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
If you enter the command without parameters, all the entries in the database are displayed.
Examples
This example shows how to display the FSPF interface information:
switch# show fspf vsan 1 fc2/1
This example shows how to display the FSPF database information:
switch# show fspf database vsan 1
FSPF Link State Database for VSAN 1 Domain 0xc6(198)
Advertising domain ID = 0xc6(198)
LSR Incarnation number = 0x800007c5
NbrDomainId IfIndex NbrIfIndex Link Type Cost
-----------------------------------------------------------------------------
This command shows how to display the FSPF information for a specified VSAN:
FSPF routing administration status is enabled
FSPF routing operational status is UP
It is an intra-domain router
MinLsArrival = 1000 msec, MinLsInterval = 2000 msec
Local Domain is 0xc6(198)
Number of LSRs = 1, Total Checksum = 0x000035d2
LS_REFRESH_TIME = 30 minutes (1800 sec)
MAX_AGE = 60 minutes (3600 sec)
Number of LSR that reached MaxAge = 0
Number of SPF computations = 0
Number of Checksum Errors = 0
Number of Transmitted packets : LSU 0 LSA 0 Hello 0 Retranmsitted LSU 0
Number of received packets : LSU 0 LSA 0 Hello 0 Error packets 0
This command shows how to display the FSPF information for all interfaces:
switch# show fspf interface
FSPF interface vfc5 in VSAN 1
FSPF routing administrative state is active
Timer intervals configured, Hello 20 s, Dead 80 s, Retransmit 5 s
show in-order-guarantee
To display the present configured state of the in-order delivery feature, use the show in-order-guarantee command.
show in-order-guarantee
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the present configuration status of the in-order delivery feature:
switch# show in-order-guarantee
Related Commands
|
|
in-order-guarantee |
Enables in-order delivery. |
show interface fcoe
To display information about the Fibre Channel over Ethernet (FCoE) for an interface, use the show interface fcoe command.
show interface [ interface number ] fcoe
Syntax Description
interface |
(Optional) Interface, either Ethernet or EtherChannel. |
number |
Interface number. The number can be one of the following:
- The Ethernet interface slot and the port number within the slot. The slot number range is from 1 to 255, and the port number range is from 1/255.
- The EtherChannel number. The range is from 1 to 4096.
|
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the FCoE information for Ethernet interfaces:
switch# show interface fcoe
Ethernet1/11 is FCoE down
Ethernet1/12 is FCoE down
Ethernet1/15 is FCoE down
Ethernet1/16 is FCoE down
Ethernet1/18 is FCoE down
PWWN is 10:00:00:00:07:f8:0e:45
MAC addr is 00:00:00:13:05:01
PWWN is 10:00:00:00:07:f8:21:bf
MAC addr is 00:00:00:13:05:01
PWWN is 10:00:00:00:07:f8:0e:46
MAC addr is 00:00:00:13:05:02
PWWN is 10:00:00:00:07:f8:21:c0
MAC addr is 00:00:00:13:05:02
PWWN is 10:00:00:00:07:f8:0e:48
MAC addr is 00:00:00:13:05:04
PWWN is 10:00:00:00:07:f8:21:c2
MAC addr is 00:00:00:13:05:04
PWWN is 10:00:00:00:07:f8:0e:49
MAC addr is 00:00:00:13:05:05
PWWN is 10:00:00:00:07:f8:21:c3
MAC addr is 00:00:00:13:05:05
PWWN is 10:00:00:00:07:f8:0e:4a
MAC addr is 00:00:00:13:05:06
PWWN is 10:00:00:00:07:f8:21:c4
MAC addr is 00:00:00:13:05:06
Ethernet1/34 is FCoE down
This example shows how to display the FCoE information for a specific Ethernet interface:
switch# show interface ethernet 1/21 fcoe
This example shows how to display the FCoE information for a specific EtherChannel interface:
switch# show interface port-channel 3 fcoe
Related Commands
|
|
show fcoe |
Displays the status of the FCoE parameters. |
show interface san-port-channel
To display the configuration information of SAN port channel interfaces, use the show interface san-port-channel command.
show interface san-port-channel port-num [ brief | counters [ brief ] | trunk vsan [ vsan-range ]]
Syntax Description
port-num |
SAN port channel interface ID. The range is from 1 to 256. |
brief |
(Optional) Displays brief information about the SAN port channel interfaces. |
counters |
(Optional) Displays the SAN port channel interface counters. |
trunk |
(Optional) Displays the SAN port channel interface trunk information. |
vsan |
(Optional) Displays the per VSAN information for the SAN port channel interface trunk. |
vsan-range |
(Optional) VSAN range. The range is from 1 to 4093. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the configuration information for a specified SAN port channel interface:
switch# show interface san-port-channel 101
san-port-channel 101 is down (No operational members)
Hardware is Fibre Channel
Port WWN is 24:65:00:05:9b:74:a6:c0
Admin port mode is NP, trunk mode is off
snmp link state traps are enabled
1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
0 input OLS, 0 LRR, 0 NOS, 0 loop inits
0 output OLS, 0 LRR, 0 NOS, 0 loop inits
last clearing of "show interface" counters never
This example shows how to display the summary information of the counters of a specified SAN port channel interface:
switch# show interface san-port-channel 101 counters brief
-------------------------------------------------------------------------------
Interface Input (rate is 1 min avg) Output (rate is 1 min avg)
--------------------------- -----------------------------
-------------------------------------------------------------------------------
san-port-channel 101 0 0 0 0
Related Commands
|
|
interface san-port-channel |
Configures a SAN port channel interface. |
show interface |
Displays an interface configuration for a specified interface. |
show running-config interface san-port-channel |
Displays the running configuration information for SAN port channels. |
show interface vfc
To display the configuration information of virtual Fibre Channel interfaces, use the show interface vfc command.
show interface vfc vfc-id [ brief ] [ counters ]
Syntax Description
vfc-id |
Virtual Fibre Channel interface ID. The range is from 1 to 8192. |
brief |
(Optional) Displays brief information about the virtual Fibre Channel interfaces. |
counters |
(Optional) Displays the virtual Fibre Channel interface counters. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the configuration information for a specified virtual Fibre Channel interface:
switch# show interface vfc 1
vfc1 is down (Administratively down)
Bound MAC is 00:50:3e:8d:64:00
Hardware is Virtual Fibre Channel
Port WWN is 20:00:00:05:9b:23:40:7f
Admin port mode is F, trunk mode is on
snmp link state traps are enabled
1 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
1 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
last clearing of "show interface" counters never
This example shows how to display a brief information for a specified virtual Fibre Channel interface:
switch# show interface vfc 5 brief
-------------------------------------------------------------------------------
Interface Vsan Admin Admin Status SFP Oper Oper Port
Mode Trunk Mode Speed Channel
-------------------------------------------------------------------------------
vfc5 1 E on down -- -- --
This example shows how to display the counters for a specified virtual Fibre Channel interface:
switch# show interface vfc 5 counters
5 minute input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minute output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
0 discards, 0 errors, 0 CRC
0 input OLS, 0 LRR, 0 NOS, 0 loop inits
0 output OLS, 0 LRR, 0 NOS, 0 loop inits
0 link failures, 0 sync losses, 0 signal losses
0 BB credit transitions from zero
Related Commands
|
|
interface vfc |
Configures a virtual Fibre Channel interface. |
show lldp
To display information about the Link Layer Discovery Protocol (LLDP) configuration on the switch, use the show lldp command.
show lldp { interface { ethernet slot / port | mgmt intf-no } | neighbors [ detail | interface ] | timers | traffic [ interface { ethernet slot / port | mgmt intf-no }]}
Syntax Description
interface |
Displays LLDP interface information, or LLDP neighbor information on an interface. |
ethernet slot / port |
Displays the configuration information of the Ethernet IEEE 802.3z interface. The slot number is from 1 to 255, and the port number is from 1 to 128. |
mgmt intf-no |
Displays the configuration information of the management interface. The management interface number is 0. |
neighbors |
Displays information about LLDP neighbors. |
detail |
(Optional) Displays the detailed information about LLDP neighbors. |
timers |
Displays information about LLDP timers. |
traffic |
Displays the LLDP counters configured on the switch. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display LLDP interface information:
switch# show lldp traffic interface ethernet 1/1
LLDP interface traffic statistics:
Total frames transmitted: 7490
Total frames received: 7458
Total frames received in error: 0
Total frames discarded: 0
Total unrecognized TLVs: 0
This example shows how to display LLDP management interface information:
switch# show lldp traffic interface mgmt 0
LLDP interface traffic statistics:
Total frames transmitted: 0
Total frames received in error: 0
Total frames discarded: 0
Total unrecognized TLVs: 0
This example shows how to display LLDP timers configured on the switch:
Reinit-time in seconds: 2
Transmit interval in seconds: 30
This example shows how to display LLDP neighbor information:
switch# show lldp neighbors
(R) Router, (B) Bridge, (T) Telephone, (C) DOCSIS Cable Device
(W) WLAN Access Point, (P) Repeater, (S) Station, (O) Other
Local Intf Chassis ID Port ID Hold-time Capability
Eth1/1 000d.eca3.6080 Eth1/1 120 B
Eth1/2 000d.eca3.6080 Eth1/2 120 B
Eth1/3 000d.eca3.6080 Eth1/3 120 B
Eth1/4 000d.eca3.6080 Eth1/4 120 B
Eth1/7 000d.ecf2.0880 Eth1/7 120 B
Eth1/8 000d.ecf2.0880 Eth1/8 120 B
Eth1/9 000d.ecf2.0b40 Eth1/9 120 B
Eth1/10 000d.ecf2.0b40 Eth1/10 120 B
This example shows how to display LLDP information for a specified interface:
switch# show lldp interface ethernet 1/1
Enable (tx/rx/dcbx): Y/Y/Y Port Mac address: 00:0d:ec:b2:30:c8
004 009 4e354b2d 506f7274 00
005 013 45756765 6e652d4e 354b2d32 00
006 010 4e354b2d 53776974 6368
008 012 05010ac1 8303021a 00000000
128 055 001b2102 020a0000 00000001 00000001 06060000 80000808 080a0000
80008906 001b2108 04110000 80000001 00003232 00000000 000002
This example shows how to display LLDP traffic information:
switch# show lldp traffic
Total frames transmitted: 89743
Total frames received: 59300
Total frames received in error: 0
Total frames discarded: 0
Total unrecognized TLVs: 0
Related Commands
|
|
lldp |
Configures the global LLDP options on the switch. |
lldp (Interface) |
Configures the LLDP feature on an interface. |
show loadbalancing
To display load balancing status for specific unicast flows, use the show loadbalancing command.
show loadbalancing vsan vsan-id source-fcid dest-fcid [ exchange-id ]
Syntax Description
vsan vsan-id |
Displays Fabric login (FLOGI) database entries based on the FCID allocated. The format is 0xhhhhhh. |
source-fcid |
Displays the load balancing status for the specified source FCID. The format is 0xhhhhhh. |
dest-fcid |
Displays the load balancing status for the specified destination FCID. The format is 0xhhhhhh. |
exchange-id |
(Optional) Displays the load balancing status for the specified exchange. The format is 0xhhhhhh. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the load-balancing information for the specified source and destination in VSAN 3:
switch# show loadbalancing vsan 3 0x3345 0x2546
Related Commands
|
|
vsan |
Configures VSAN information or membership. |
show npv flogi-table
To display the information about N port virtualization (NPV) Fabric login (FLOGI) session, use the show npv flogi-table command.
show npv flogi-table
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The show npv flogi-table command is available only when the switch is in NPV mode.
Examples
This example shows how to display the information on NPV FLOGI session:
switch# show npv flogi-table
Related Commands
|
|
show npv status |
Displays the NPV current status. |
show npv status
To display the N port virtualization (NPV) current status, use the show npv status command.
show npv status
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The show npv status command is available only when the switch is in NPV mode.
Examples
This example shows how to display the current status of NPV :
Related Commands
|
|
show npv flogi-table |
Displays the information about NPV FLOGI session. |
show npv traffic-map
To display N port virtualization (NPV) traffic maps, use the show npv traffic-map command.
show npv traffic-map
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The show npv traffic-map command is available only when the switch is in NPV mode.
Examples
This example shows how to display the current status of NPV :
switch# show npv traffic-map
Related Commands
|
|
show npv flogi-table |
Displays the information about an NPV FLOGI session. |
show port index-allocation
To display port index allocation information, use the show port index-allocation command.
show port index-allocation [ startup ]
Syntax Description
startup |
(Optional) Displays port index allocation information at startup. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
On a switch where the maximum number of port indexes is 256, any module that exceeds that limit does not power up. There is no startup module index distribution for the Cisco Nexus 5500 Series switch.
Examples
This example shows how to display port index allocation information:
switch# show port index-allocation
show rlir
To display Registered Link Incident Report (RLIR) information, use the show rlir command.
show rlir { erl [ vsan vsan-id ] | history | recent { interface fc slot / port | portnumber port } | statistics [ vsan vsan-id ]}
Syntax Description
erl |
Displays the Established Registration List. |
vsan vsan-id |
(Optional) Specifies a VSAN ID. The range is from 1 to 4093. |
history |
Displays the link incident history. |
recent |
Displays recent link incidents. |
interface fc slot / port |
Specifies a Fibre Channel interface. |
portnumber port |
Displays RLIR information for the specified port number. |
statistics |
Displays RLIR statistics for all VSANs or the specified VSAN. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the RLIR information for VSAN 1:
switch# show rlir erl vsan 1
This example shows how to display the RLIR statistics:
switch# show rlir statistics vsan 1
Related Commands
|
|
rlir preferred-cond fcid |
Specifies a preferred host to receive RLIR frames. |
show rscn
To display Registered State Change Notification (RSCN) information, use the show rscn command.
show rscn { event-tov vsan vsan-id | pending vsan vsan-id | pending-diff vsan vsan-id | scr-table [ vsan vsan-id ] | session status vsan vsan-id | statistics [ vsan vsan-id ]}
Syntax Description
event-tov |
Displays the event timeout value. |
vsan vsan-id |
Specifies a VSAN ID. The range is from 1 to 4093. |
pending |
Displays the pending configuration. |
pending-diff |
Displays the difference between the active and the pending configuration. |
scr-table |
Displays the State Change Registration (SCR) table. |
session status |
Displays the RSCN session status. |
statistics |
Displays RSCN statistics. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
The SCR table cannot be configured. It is only populated if one or more N ports send SCR frames to register for RSCN information. If the show rscn scr-table command does not return any entries, no N port is interested in receiving RSCN information.
Examples
This example shows how to display the RSCN information:
switch# show rscn scr-table vsan 1
This example shows how to display the RSCN statistics:
switch# show rscn statistics vsan 1
This example shows how to display the RSCN event timeout value configured on VSAN 1:
switch# show rscn event-tov vsan 1
This example shows how to display the difference between the active RSCN configuration and the pending RSCN configuration on VSAN 1:
switch# show rscn pending-diff vsan 1
Related Commands
|
|
rscn |
Configures a registered state change notification (RSCN). |
show running-config fcoe_mgr
To display the running configuration information about Fibre Channel over Ethernet (FCoE), use the show running-config fcoe_mgr command.
show running-config fcoe_mgr [ all ]
Syntax Description
all |
(Optional) Displays the full operating information including default settings. |
Command Modes
EXEC mode
Command History
|
|
5.0(3)N2(1) |
This command was introduced. |
Examples
This example shows how to display the FCoE running configuration information:
switch# show running-config fcoe_mgr
!Command: show running-config fcoe_mgr
!Time: Fri Jan 2 06:33:11 2009
bind mac-address 00:50:3e:8d:64:00
This example shows how to display detailed information on the running configuration:
switch# show running-config fcoe_mgr all
!Command: show running-config fcoe_mgr all
!Time: Fri Jan 2 05:36:52 2009
bind mac-address 00:50:3e:8d:64:00
Related Commands
|
|
copy running-config startup-config |
Copies the running configuration information to the startup configuration file. |
show tech-support fcoe |
Displays troubleshooting information about FCoE. |
show running-config interface san-port-channel
To display the runninf system configuration information of SAN port channel interfaces, use the show running-config interface san-port-channel command.
show running-config interface san-port-channel port-num [ all | expand-port-profile ]
Syntax Description
all |
(Optional) Displays configured and default information. |
expand-port-profile |
(Optional) Displays the configuration information of port profiles. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the running configuration information for a specified SAN port channel interface:
switch# show running-config interface san-port-channel 101
!Command: show running-config interface san-port-channel 101
!Time: Mon Apr 11 09:14:20 2005
interface san-port-channel 101
Related Commands
|
|
interface san-port-channel |
Configures a SAN port channel interface. |
copy running-config startup-config |
Copies the running configuration information to the startup configuration file. |
show san-port-channel
To view information about existing SAN port channel configurations, use the show san-port-channel command.
show san-port-channel { compatibility-parameters | consistency [ detail ] | database [ interface san-port-channel port ] | summary | usage }
Syntax Description
compatibility-parameters |
Displays compatibility parameters. |
consistency |
Displays the database consistency information of all modules. |
detail |
(Optional) Displays detailed database consistency information. |
database |
Displays SAN port channel database information. |
interface san-port-channel port |
(Optional) Specifies the SAN port channel number. The range is from 1 to 256. |
summary |
Displays the SAN port channel summary. |
usage |
Displays the SAN port channel number usage. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the SAN port channel summary:
switch# show san-port-channel summary
This example shows how to display the SAN port channel compatibility parameters:
switch# show san-port-channel compatibility-parameters
This example shows how to display the SAN port channel database:
switch# show san-port-channel database
This example shows how to display the consistency status of the SAN port channel database:
switch# show san-port-channel consistency
This example shows how to display detailed information about the consistency status of the SAN port channel database:
switch# show san-port-channel consistency detail
This example shows how to display details of the used and unused SAN port channel numbers:
switch# show san-port-channel usage
Related Commands
|
|
san-port-channel persistent |
Converts an autocreated SAN port channel to a persistent SAN port channel. |
show scsi-target
To display information about existing SCSI target configurations, use the show scsi-target command.
show scsi-target { auto-poll | custom-list | devices [ vsan vsan-id ] [ fcid fcid-id ] | disk [ vsan vsan-id ] [ fcid fcid-id ] | lun [ vsan vsan-id ] [ fcid fcid-id ] [ os [ aix | all | hpux | linux | solaris | windows ] | pwwn | status | tape [ vsan vsan-id ] [ fcid fcid-id ] | vsan vsan-id }
Syntax Description
auto-poll |
Displays SCSI target auto polling information. |
custom-list |
Displays customized discovered targets. |
devices |
Displays discovered SCSI target devices information. |
vsan vsan-id |
(Optional) Specifies the Virtual SAN (VSAN) ID. The range is from 1 to 4093. |
fcid fcid-id |
(Optional) Specifies the FCID of the SCSI target to display. |
disk |
Displays discovered disk information. |
lun |
Displays discovered SCSI target logical unit number (LUN) information. |
os |
(Optional) Discovers the specified operating system. |
aix |
(Optional) Specifies the AIX operating system. |
all |
(Optional) Specifies all operating systems. |
hpux |
(Optional) Specifies the HPUX operating system. |
linux |
(Optional) Specifies the Linux operating system. |
solaris |
(Optional) Specifies the Solaris operating system. |
windows |
(Optional) Specifies the Windows operating system. |
pwwn |
Displays discovered pWWN information for each operating system. |
status |
Displays the SCSI target discovery status. |
tape |
Displays discovered tape information. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
Use the show scsi-target auto-poll command to verify automatic discovery of online SCSI targets.
Examples
This example shows how to display the status of a SCSI discovery:
switch# show scsi-target status
This example shows how to display the customized discovered targets:
switch# show scsi-target custom-list
This example shows how to display the discovered disk information:
switch# show scsi-target disk
This example shows how to display the discovered LUNs for all operating systems:
switch# show scsi-target lun os all
This example shows how to display the discovered LUNs for the Solaris operating system:
switch# show scsi-target lun os solaris
This example shows how to display the auto-polling information:
switch# show scsi-target auto-poll
This example shows how to display the port WWN that is assigned to each operating system (Windows, AIX, Solaris, Linux, or HPUX):
switch# show scsi-target pwwn
Related Commands
|
|
scsi-target |
Configures SCSI target discovery. |
show startup-config fcoe_mgr
To display the startup configuration information about Fibre Channel over Ethernet (FCoE), use the show startup-config fcoe_mgr command.
show startup-config fcoe_mgr
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(3)N2(1) |
This command was introduced. |
Examples
This example shows how to display the FCoE startup configuration information:
switch# show startup-config fcoe_mgr
!Command: show startup-config fcoe_mgr
!Time: Fri Jan 2 05:41:38 2009
!Startup config saved at: Thu Jan 1 00:04:46 2009
bind mac-address 00:50:3e:8d:64:00
Related Commands
|
|
copy running-config startup-config |
Copies the running configuration information to the startup configuration file. |
show tech-support fcoe |
Displays troubleshooting information about FCoE. |
show tech-support fcoe
To display troubleshooting information about Fibre Channel over Ethernet (FCoE), use the show tech-support fcoe command.
show tech-support fcoe
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(3)N2(1) |
This command was introduced. |
Examples
This example shows how to display Cisco technical support information for FCoE interfaces:
switch# show tech-support fcoe
******************** FCOE MGR tech-support start *****************
`show platform software fcoe_mgr event-history errors`
1) Event:E_DEBUG, length:71, at 269945 usecs after Fri Jan 2 06:35:17 2009
[102] fcoe_mgr_demux(535): (Warning) unexpected mts msg (opcode - 7972)
2) Event:E_DEBUG, length:64, at 269136 usecs after Fri Jan 2 06:35:17 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5428): fka-adv-period: 60
3) Event:E_DEBUG, length:64, at 269107 usecs after Fri Jan 2 06:35:17 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5427): fcf-priority : 128
4) Event:E_DEBUG, length:68, at 269076 usecs after Fri Jan 2 06:35:17 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5426): fcmap : 0xefc00
5) Event:E_DEBUG, length:100, at 269036 usecs after Fri Jan 2 06:35:17 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5425): fcoe_mgr_pss_add_global_cfg_da
6) Event:E_DEBUG, length:88, at 268788 usecs after Fri Jan 2 06:35:17 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5400): fcoe_mgr_pss_add_global_cfg_data: Entering
7) Event:E_DEBUG, length:63, at 567997 usecs after Fri Jan 2 06:30:27 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5428): fka-adv-period: 8
8) Event:E_DEBUG, length:64, at 567965 usecs after Fri Jan 2 06:30:27 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5427): fcf-priority : 128
9) Event:E_DEBUG, length:68, at 567932 usecs after Fri Jan 2 06:30:27 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5426): fcmap : 0xefc00
10) Event:E_DEBUG, length:100, at 567891 usecs after Fri Jan 2 06:30:27 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5425): fcoe_mgr_pss_add_global_cfg_da
11) Event:E_DEBUG, length:88, at 567732 usecs after Fri Jan 2 06:30:27 2009
[102] fcoe_mgr_pss_add_global_cfg_data(5400): fcoe_mgr_pss_add_global_cfg_da
12) Event:E_DEBUG, length:88, at 567667 usecs after Fri Jan 2 06:30:27 2009
[102] fcoe_mgr_cli_set_ve_loopback(1562): Enabling VE loopback (will disable
13) Event:E_DEBUG, length:129, at 177534 usecs after Fri Jan 2 06:25:17 2009
[102] fcoe_mgr_mts_vfc_bind_check_resp_handler(2488): Bind Check Resp: if_in
dex: 0x0, status: (null): success (err_id 0x00000000)
14) Event:E_DEBUG, length:71, at 176687 usecs after Fri Jan 2 06:25:17 2009
[102] fcoe_mgr_demux(535): (Warning) unexpected mts msg (opcode - 7972)
15) Event:E_DEBUG, length:71, at 392038 usecs after Fri Jan 2 06:16:00 2009
[102] fcoe_mgr_mac_pool_bmp_to_tlv(143): mac_pool->mac_usage_bmp = NULL
16) Event:E_DEBUG, length:63, at 89603 usecs after Fri Jan 2 06:16:00 2009
[102] fcoe_mgr_get_eth_fcoe_info(58): sending lls down Eth1/31
17) Event:E_DEBUG, length:63, at 89509 usecs after Fri Jan 2 06:16:00 2009
[102] fcoe_mgr_get_eth_fcoe_info(58): sending lls down Eth1/29
18) Event:E_DEBUG, length:63, at 89405 usecs after Fri Jan 2 06:16:00 2009
[102] fcoe_mgr_get_eth_fcoe_info(58): sending lls down Eth1/18
19) Event:E_DEBUG, length:63, at 89310 usecs after Fri Jan 2 06:16:00 2009
[102] fcoe_mgr_get_eth_fcoe_info(58): sending lls down Eth1/17
20) Event:E_DEBUG, length:63, at 89212 usecs after Fri Jan 2 06:16:00 2009
[102] fcoe_mgr_get_eth_fcoe_info(58): sending lls down Eth1/15
21) Event:E_DEBUG, length:62, at 89101 usecs after Fri Jan 2 06:16:00 2009
[102] fcoe_mgr_get_eth_fcoe_info(58): sending lls down Eth1/8
Related Commands
|
|
show running-config fcoe_mgr |
Displays the running configuration information about FCoE. |
show topology
To display topology information for connected SAN switches, use the show topology command.
show topology [ vsan vsan-id ]
Syntax Description
vsan vsan-id |
(Optional) Displays information for a VSAN. The range is from 1 to 4093. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display topology information:
Related Commands
|
|
cfs ipv4 mcast-address |
Configures an IPv4 multicast address for Cisco Fabric Services (CFS) distribution over IPv4. |
cfs ipv6 distribute |
Enables CFS distribution over IPv6 for applications using CFS. |
cfs ipv6 mcast-address |
Configures an IPv6 multicast address for CFS distribution over IPv6. |
show trunk protocol
To display the trunk protocol status, use the show trunk protocol command.
show trunk protocol
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the trunk protocol status:
switch# show trunk protocol
Related Commands
|
|
trunk protocol enable |
Configures the trunking protocol for Fibre Channel interfaces. |
show vlan fcoe
To display information about the Fibre Channel over Ethernet (FCOE) VLAN to Virtual SAN (VSAN) mappings, use the show vlan fcoe command.
show vlan fcoe
Syntax Description
This command has no arguments or keywords.
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the FCoE VLAN to VSAN mappings on the switch:
-------- -------- --------
Related Commands
|
|
fcoe vsan |
Maps a FCoE VLAN to a VSAN. |
show vsan
To display information about a configured Virtual SAN (VSAN), use the show vsan command.
show vsan [ vsan-id [ membership ] | membership [ interface { fc slot / port | san-port-channel port | vfc vfc-id }] | usage ]
Syntax Description
vsan-id |
(Optional) Information for the specified VSAN ID. The range is from 1 to 4094. |
membership |
(Optional) Displays membership information. |
interface |
(Optional) Specifies the interface type. |
fc slot / port |
Specifies a Fibre Channel interface. |
san-port-channel port |
Specifies a SAN port channel interface specified by the port channel number. |
vfc vfc-id |
Specifies a virtual Fibre Channel interface. |
usage |
(Optional) Displays VSAN usage in the system. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Usage Guidelines
When you enter the show vsan membership interface command, interface information appears for interfaces that are configured in this VSAN.
The interface range must be in ascending order and nonoverlapping. You can specify a range using a hyphen and several interfaces using commas:
- The interface range format for a Fibre Channel interface range is
fcslot/port - port, fcslot/port, fcslot/port:
For example, show int fc2/1 - 3, fc2/4, fc3/2
Examples
This example shows how to display the configured VSAN information:
name:VSAN0001 state:active
interoperability mode:default
loadbalancing:src-id/dst-id/oxid
This example shows how to display the membership information for all VSANs:
switch # show vsan membership
fc2/3 fc2/4 san-port-channel 14 vfc1
san-port-channel 8 san-port-channel 9 vfc21 vfc22
fc2/1 fc2/2 san-port-channel 13
vsan 4079(evfp_isolated_vsan) interfaces:
vsan 4094(isolated_vsan) interfaces:
This example shows how to display the membership information for a specified interface:
switch# show vsan membership interface fc2/1
allowed list:1-4078,4080-4093
show wwn
To display the status of the WWN configuration, use the show wwn command.
show wwn { status [ block-id number ] | switch | vsan-wwn }
Syntax Description
status |
Displays a summary of the WWN usage and alarm status. |
block-id number |
(Optional) Displays the WWN usage and alarm status for a block ID. The range is from 34 to 1793. |
switch |
Displays the switch WWN. |
vsan-wwn |
Displays all user-configured VSAN WWNs. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the WWN of the switch:
This example shows how to display a user-configured VSAN WWN:
switch# show wwn vsan-wwn
Related Commands
|
|
wwn vsan |
Configures a WWN for a suspended VSAN that has interop mode 4 enabled. |
show zone
To display zone information, use the show zone command.
show zone [ active [ vsan vsan-id ] | analysis { active vsan vsan-id | vsan vsan-id | zoneset zoneset-name } | ess [ vsan vsan-id ] | member { fcalias alias-name | fcid fc-id [ active | lun lun-id | vsan vsan-id ] | pwwn wwn [ active | lun lun-id | vsan vsan-id ]} | name string [ active ] [ pending ] [ vsan vsan-id ] | pending [ active ] [ vsan vsan-id ] | pending-diff [ vsan vsan-id ] | policy [ pending ] [ vsan vsan-id ] | statistics [ vsan vsan-id ] | status [ vsan vsan-id ]]
Syntax Description
active |
(Optional) Displays zones that are part of active zone set. |
vsan vsan-id |
(Optional) Displays zones belonging to the specified VSAN ID. The range is from 1 to 4093. |
analysis |
(Optional) Displays the analysis of the zone database. |
active |
Displays the analysis of the active zone database. |
vsan |
Displays the analysis of the zone database for the specified VSAN. |
zoneset zoneset-name |
Displays the analysis of the specified zone set. |
ess |
(Optional) Displays the exchange switch support (ESS) information. |
member |
(Optional) Displays all zones in which the given member is part of. |
fcalias alias-name |
Displays member information for a specific fcalias. |
fc-id fc-id |
Displays member information for a specific Fibre Channel ID. |
lun lun-id |
Displays the logical unit ID. |
pwwn wwwn |
Displays device name information for a specific pWWN. The format is hh : hh : hh : hh : hh : hh : hh : hh, where h is a hexadecimal number. |
name string |
Displays members of a specified zone. |
pending |
Displays members of a specified zone in the current session. |
pending-diff |
Displays pending changes to the zone database. |
statistics |
Displays zone server statistics. |
status |
Displays the zone server current status. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the configured zone information:
This example shows how to display the zone information for a specific VSAN:
This example shows how to display the members of a specific zone:
switch# show zone name Zone1
This example shows how to display all zones to which a member belongs using the FCID:
switch# show zone member pwwn 21:00:00:20:37:9c:48:e5
This example shows how to display the number of control frames exchanged with other switches:
switch# show zone statistics
This example shows how to display the status of the configured zones:
This example checks the status of the zoneset distribute vsan command and displays the default zone attributes of a specific VSAN or all active VSANs:
switch# show zone status vsan 1
VSAN:1 default-zone:deny distribute:active only Interop:default
mode:basic merge-control:allow session:none
qos:low broadcast:disabled ronly:disabled
Zonesets:0 Zones:0 Aliases:0
Table 3 describes the significant fields shown in the show zone status vsan display.
Table 3 show zone status Field Descriptions
|
|
VSAN: |
VSAN number displayed. |
default-zone: |
Default-zone policy, either permit or deny. |
Default zone: |
Field that displays the attributes for the specified VSAN. The attributes include Qos level, broadcast zoning enabled/disabled, and read-only zoning enabled/disabled. |
distribute: |
Distribute full-zone set (full) or active-zone set (active only). |
Interop: |
I nterop mode. 100 = default, 1 = standard, 2 and 3 = Non-Cisco vendors. |
mode: |
Zoning mode, either basic or enhanced. |
merge control: |
Merge policy, either allow or restrict. |
Hard zoning is enabled |
If hardware resources (TCAM) becomes full, hard zoning is automatically disabled. |
Full Zoning Database: |
Values of zone database. |
Active Zoning Database: |
Values of active zone database. |
Status: |
Status of last zone distribution. |
Related Commands
|
|
zone |
Configures zone information. |
show zone analysis
To display detailed analysis and statistical information about the zoning database, use the show zone analysis command.
show zone analysis { active vsan vsan-id | vsan vsan-id | zoneset name vsan vsan-id }
Syntax Description
active |
Displays analysis information for the active zone set. |
vsan vsan-id |
Displays analysis information for the specified VSAN ID. The range is from 1 to 4093. |
zoneset name |
Displays zone set analysis information for the specified zone set. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the detailed statistics and analysis of the active zoning database:
switch# show zone analysis active vsan 1
This example shows how to display the detailed statistics and analysis of the full zoning database:
switch# sh zone analysis vsan 1
Zoning database analysis vsan 1
Last updated at: 14:36:56 UTC Oct 04 2005
Last updated by: Local [CLI / SNMP / GS / CIM / INTERNAL] or
Remote [Domain, IP-Address]
Formatted database size: < 1 Kb / 2000 kb ( < 1% usage)
Table 4 describes the fields displayed in the output of a show zone analysis command for the full zoning database.
Table 4 show zone analysis Field Descriptions for the Full Zoning Database
|
|
Last updated at |
Time stamp that shows when the full zoning database was last updated. |
Last Updated by |
Agent that most recently modified the full zoning database. The agent can be one of the following three types:
- Local—Indicates that the full database was last modified locally through a configuration change from one of the following applications:
– CLI—The full zoning database was modified by the user from the command line interface. – SNMP—The full zoning database was modified by the user through the Simple Network Management Protocol (SNMP). – GS—The full zoning database was modified from the Generic Services (GS) client. – CIM—The full zoning database was modified by the applications using the Common Information Model (CIM). – INTERNAL—The full zoning database was modified as a result of an internal activation either from Inter-VSAN Routing (IVR) or from the IP storage services manager.
- Merge—Indicates that the full database was last modified by the Merge protocol. In this case, the interface on which the merge occurred is also displayed.
- Remote—Indicates that the full database was last modified by the Change protocol, initiated by a remote switch, when the full zone set distribution was enabled. The domain, IP address, and switch name of the switch initiating the change are also displayed.
Note The switch name is displayed on the next line, aligned with the domain, only if the switch name is set. The default switch name switch and the ip-address are not displayed. |
Num zonesets |
Total number of zone sets in the database. |
Num zones |
Total number of zones in the database, including unassigned zones. |
Num aliases |
Total number of aliases in the database, including unassigned FC aliases. |
Num attribute groups |
Total number of attribute groups in the database. This field applies only when enhanced zoning is used. |
Formatted database size |
Total size of the full database when formatted to be sent over the wire. The formatted database size is displayed in kilobytes in this format: < X KB / Y KB, as in the following example: Formatted database size: < 1 KB/2000 KB In this example, the formatted database size is less than 1 KB out of the maximum size of 2000 KB. |
Unassigned zones |
All the unassigned zones in the VSAN. Only the names of the zones are displayed. The details about the members of the zone are not displayed in this section. |
This example shows how to display the zone set analysis information:
switch# show zone analysis zoneset zs1 vsan 1
Related Commands
|
|
zone compact database |
Compacts a zone database in a VSAN. |
show zoneset
To display the configured zone sets, use the show zoneset command.
show zoneset [ active [ vsan vsan-id ] | brief [ active [ vsan vsan-id ] | vsan vsan-id ] | name zoneset-name [ active [ vsan vsan-id ] | brief [ active [ vsan vsan-id ] | vsan vsan-id ] | vsan vsan-id ] | pending [ active [ vsan vsan-id ] | brief [ active [ vsan vsan-id ] | vsan vsan-id ] | vsan vsan-id ] | vsan vsan-id
Syntax Description
active |
(Optional) Displays only active zone sets. |
vsan vsan-id |
(Optional) Displays the VSAN. The range is from 1 to 4093. |
brief |
(Optional) Displays zone set members in a brief list. |
name zoneset-name |
(Optional) Displays members of a specified zone set. |
pending |
(Optional) Displays zone sets members that are in session. |
Command Modes
EXEC mode
Command History
|
|
5.0(2)N1(1) |
This command was introduced. |
Examples
This example shows how to display the configured zone set information:
switch# show zoneset vsan 1
This example shows how to display the configured zone set information for a specific VSAN:
switch# show zoneset vsan 2-3
Related Commands
|
|
zoneset (Global configuration mode) |
Groups zones under one zone set. |
zoneset (EXEC mode) |
Merges zone set databases. |