Introducción
Este documento describe un problema y una solución acerca de los switches Catalyst serie 9000 que no se inician normalmente y caen en el indicador del cargador de arranque.
Problema
Recarga del chasis 2. El motivo es que la selección Activo/En espera ha fallado en el modo 1+1.
switch: boot
attempting to boot from [flash:packages.conf]
Located file packages.conf
#
##########################################################################################################################
Validate packages: SHA-1 hash:
calculated 550C9730:667B2788:DD6F6B06:D0FFA819:01A315DA
expected 550C9730:667B2788:DD6F6B06:D0FFA819:01A315DA
Both links down, not waiting for other switches
Switch number is 2
Chassis 2 reloading, reason - Active/standby selection failed in 1+1 Mode <<<<<<
Feb 19 20:06:55.572 FP0/0: %PMAN-5-EXITACTION: Process manager is exiting: reload fp action requested
Feb 19 20:06:57
Initializing Hardware...
System Bootstrap, Version 16.6.1r [FC1], RELEASE SOFTWARE (P)
Compiled Sat 07/15/2017 8:31:57.39 by rel
Current image running:
Primary Rommon Image
Last reset cause: SoftwareReload
C9300-48U platform with 8388608 Kbytes of main memory
attempting to boot from [flash:packages.conf]
Located file packages.conf
#
##########################################################################################################################
Validate packages: SHA-1 hash:
calculated 550C9730:667B2788:DD6F6B06:D0FFA819:01A315DA
expected 550C9730:667B2788:DD6F6B06:D0FFA819:01A315DA
Otra manera de identificar este problema es observar la variable del cargador de inicialización STACK 1+1 con el uso del set comando en el modo del cargador de inicialización. Para poner el switch en modo de cargador de arranque, haga clic en el mode botón mientras el switch comienza a arrancar.
switch: set
ABNORMAL_RESET_COUNT=0
AUTOREBOOT_RESTORE=1
BOARDID=20569
BOOT=flash:packages.conf
BSI=0
MAC_ADDR=00:ab:cd:ef:01
MANUAL_BOOT=yes
MODEL_NUM=C9300-48UXM
MODEL_REVISION_NUM=D0
MOTHERBOARD_ASSEMBLY_NUM=73-17959-06
MOTHERBOARD_REVISION_NUM=A0
MOTHERBOARD_SERIAL_NUM=XXXXXXXXXXX
RANDOM_NUM=1901228755
RET_2_RCALTS=
ROMMON_AUTOBOOT_ATTEMPT=3
STACK_1_1=2_0 <<<<<<<
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=2
SYSTEM_SERIAL_NUM=XXXXXXXXXXXX
TEMPLATE=access
VERSION_ID=V01
switch:
Solución
Desactive la variable Stack 1+1. Después, este switch puede arrancar normalmente.
switch:unset STACK_1_1
switch: set
ABNORMAL_RESET_COUNT=0
AUTOREBOOT_RESTORE=1
BOARDID=20569
BOOT=flash:packages.conf
BSI=0
MAC_ADDR=00:ab:cd:ef:01
MANUAL_BOOT=yes
MODEL_NUM=C9300-48UXM
MODEL_REVISION_NUM=D0
MOTHERBOARD_ASSEMBLY_NUM=73-17959-06
MOTHERBOARD_REVISION_NUM=A0
MOTHERBOARD_SERIAL_NUM=XXXXXXXXXXX
RANDOM_NUM=1901228755
RET_2_RCALTS=
ROMMON_AUTOBOOT_ATTEMPT=3
SWITCH_IGNORE_STARTUP_CFG=1
SWITCH_NUMBER=2
SYSTEM_SERIAL_NUM=XXXXXXXXXX
TEMPLATE=access
VERSION_ID=V01
switch:
Una vez que la variable del cargador de inicialización de Stack 1+1 no está establecida, emita el boot comando para que el switch pueda arrancar desde la variable de inicio establecida en el switch.
switch: boot
attempting to boot from [flash:packages.conf]
Located file packages.conf
#
##########################################################################################################################
Validate packages: SHA-1 hash:
calculated 550C9730:667B2788:DD6F6B06:D0FFA819:01A315DA
expected 550C9730:667B2788:DD6F6B06:D0FFA819:01A315DA
Both links down, not waiting for other switches
Switch number is 2
Información Relacionada
Para obtener información sobre el modo Stack 1+1, consulte Redundancia 1:1.