サーバー上でサポートされている Cisco IMC 障害
障害コード |
障害名 |
メッセージ |
重大度 |
原因 |
---|---|---|---|---|
F0174 |
fltProcessorUnitInoperable |
Processor [id] on server [chassisId]/[slotId] operability: [operability] |
メジャー |
機器が動作不能 |
F0176 |
fltProcessorUnitThermalThreshold 重大 |
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal] |
メジャー |
温度の問題 |
F0177 |
fltProcessorUnitThermalThreshold NonRecoverable |
Processor [id] on server [chassisId]/[slotId] temperature: [thermal]Processor [id] on server [id] temperature: [thermal] |
重大 |
温度の問題 |
F0185 |
fltMemoryUnitInoperable |
DIMM [location] on server [chassisId]/[slotId] operability: [operability]DIMM [location] on server [id] operability: [operability] |
メジャー |
機器が動作不能 |
F0187 |
fltMemoryUnitThermalThreshold 重大 |
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal] |
メジャー |
温度の問題 |
F0188 |
fltMemoryUnitThermalThreshold NonRecoverable |
DIMM [location] on server [chassisId]/[slotId] temperature: [thermal]DIMM [location] on server [id] temperature: [thermal] |
重大 |
温度の問題 |
F0203 |
fltAdaptorUnitMissing |
Adapter [id] in server [id] presence: [presence]Adapter [id] in server [chassisId]/[slotId] presence: [presence] |
警告 |
機器の欠落 |
F0310 |
fltComputeBoardPowerError |
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [operPower]Motherboard of server [id] (service profile: [assignedToDn]) power: [operPower] |
メジャー |
電源に関する問題 |
F0313 |
fltComputePhysicalBiosPostTimeout |
Server [id] (service profile: [assignedToDn]) BIOS failed power-on self testServer [chassisId]/[slotId] (service profile: [assignedToDn]) BIOS failed power-on self test |
重大 |
機器が動作不能 |
F0409 |
fltEquipmentChassisThermalThreshold 重大 |
シャーシの温度の問題 [id] 原因: [thermalStateQualifier] |
メジャー |
温度の問題 |
F0411 |
fltEquipmentChassisThermalThreshold NonRecoverable |
シャーシの温度の問題 [id] 原因:[thermalStateQualifier] |
重大 |
温度の問題 |
F0842 |
fltProcessorUnitDisabled |
Processor [id] on server [chassisId]/[slotId] operState: [operState]Processor [id] on server [id] operState: [operState] |
[情報(Info)] |
機器が無効です |
F0844 |
fltMemoryUnitDisabled |
DIMM [location] on server [chassisId]/[slotId] operState: [operState]DIMM [location] on server [id] operaState: [operState] |
メジャー |
機器が無効です |
F0868 |
fltComputeBoardPowerFail |
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) power: [power]Motherboard of server [id] (service profile: [assignedToDn]) power: [power] |
重大 |
電源に関する問題 |
F0869 |
fltComputeABoardThermalProblem |
Motherboard of server [chassisId]/[slotId] (service profile: [assignedToDn]) thermal: [thermal]Motherboard of server [id] (service profile: [assignedToDn]) thermal: [thermal] |
Minor |
温度の問題 |
F0918 |
fltComputeABoardMotherBoardVoltage ThresholdUpperNonRecoverable |
Motherboard input voltage in server [id] is [voltage]Motherboard [faultQualifier] input voltage in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/ [slotId]/[serverInstanceId] は [voltage] です |
メジャー |
電圧の問題 |
F0920 |
fltComputeABoardMotherBoardVoltage UpperThresholdCritical |
Motherboard input voltage in server [id] is [voltage]Motherboard [faultQualifier] input voltage in server [chassisId]/[slotId] is [voltage]Motherboard input voltage(12V/5V/3V) in server [chassisId]/ [slotId]/[serverInstanceId] は [voltage] です |
Minor |
電圧の問題 |
F1257 |
fltStorageFlexFlashControllerInoperable |
FlexFlash Controller [id] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is inoperable. Reason: [operQualifierReason] Status: [controllerHealth] |
メジャー |
機器が動作不能 |
F1258 |
fltStorageFlexFlashCardInoperable |
FlexFlash Card [slotNumber] on server [chassisId]/[slotId] is inoperable. Reason: [operQualifierReason] FlexFlash カード [slotNumber] がオン サーバー [id] は操作不能です。 Reason: [operQualifierReason] |
メジャー |
機器が動作不能 |
F1259 |
fltStorageFlexFlashCardMissing |
FlexFlash Card [slotNumber] missing on server [chassisId]/[slotId]FlexFlash Card [slotNumber] missing on server [id] |
[情報(Info)] |
機器の欠落 |
F1260 |
fltStorageFlexFlashVirtual DriveDegraded |
FlexFlash Virtual Drive RAID degraded on server [chassisId]/[slotId]. Reason: [raidState]FlexFlash Virtual Drive RAID degraded on server [id]. Reason: [raidState] |
Minor |
機器の劣化 |
F1261 |
fltStorageFlexFlashVirtualDrive 操作不能 |
FlexFlash Virtual Drive on server [chassisId]/[slotId] is inoperable. Reason: [raidState]FlexFlash Virtual Drive on server [id] is inoperable. Reason: [raidState] |
メジャー |
機器が動作不能 |
F1262 |
fltStorageFlexFlashControllerUnhealthy |
FlexFlash Controller [id] on server [chassisId]/[slotId] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth]FlexFlash Controller [id] on server [id] is unhealthy. Reason: [operQualifierReason] Status: [controllerHealth] |
Minor |
機器が動作不能 |
F1004 |
fltStorageControllerInoperable |
サーバー [chassisId]/[slotId] のコントローラ [id] が動作不能です。Reason: [operQualifierReason] Status: [controllerHealth] |
メジャー |
機器が動作不能 |
F1003 |
fltStorageControllerPatrolReadFailed |
サーバー [chassisId]/[slotId] のストレージ コントローラ [id] patrolReadFailed 理由: [operQualifierReason] ステータス: [controllerHealth] |
警告 |
設備不健康 |
F181 |
fltStorageLocalDiskInoperable |
サーバー [chassisId]/[slotId] のストレージ ローカル ディスク slotNumber] が動作不能です。Reason: [operQualifierReason] サーバー [id] の StorageLocalDisk [slotNumber] は操作できません。 |
メジャー |
機器が動作不能 |
F996 |
fltStorageLocalDiskDegraded |
StorageLocalDisk [slotNumber] サーバー [chassisId]/ で劣化 [slotId]StorageController [slotNumber] サーバー [id] で劣化 |
警告 |
機器の劣化 |
F1256 |
fltStorageLocalDiskMissing |
サーバー [chassisId]/[slotId] の StorageLocalDiskMissing。理由: StorageLocalDisk がありません |
警告 |
機器の欠落 |
F1005 |
fltStorageLocalDiskRebuildFailed |
StorageLocalDiskon サーバー [chassisId]/[slotId] が再構築に失敗しました。理由: サーバー [id] の StorageLocalDisk が再構築に失敗しました |
警告 |
設備不健康 |
F1006 |
fltStorageLocalDiskCopybackFailed |
StorageLocalDiskon サーバー [chassisId]/[slotId] が再構築に失敗しました。理由: サーバー [[id] の StorageLocalDisk が copyback に失敗しました。 |
警告 |
設備不健康 |
F1007 |
fltStorageVirtulDriveInoperable |
サーバー [chassisId]/[slotId] の slotNumber] のストレージ VirtualDrive が動作不能です。Reason: [operQualifierReason] StorageLocalDisk [slotNumber] サーバー [id] は操作不能です |
メジャー |
機器が動作不能 |
F1008 |
fltStorageVirtualDriveDegraded |
Virtual drive [id] on [serverid] の仮想ドライブ [id] の動作能力:[operability] |
警告 |
機器の劣化 |
F1010 |
fltStorageVirtualDriveConsistency CheckFailed |
Virtual drive [id] on [serverid] の仮想ドライブ [id] の動作能力:[operability] |
警告 |
設備不健康 |
F997 |
fltStorageRaidBatteryDegraded |
サーバー [chassisId]/[slotId] のストレージ コントローラ [id] RaidBattery が劣化している 理由: [operQualifierReason] ステータス: [controllerHealth] |
警告 |
機器の劣化 |
F999 |
fltStorageRaidBatteryRelearnFailed |
サーバー [chassisId]/[slotId] のストレージ コントローラ [id] RelearnFailed が劣化している 理由: [operQualifierReason] ステータス: [controllerHealth] |
警告 |
設備不健康 |
F1783 |
fltEquipmentTpmTpmMismatch |
インストールされている TPM は、サーバー構成では現在動作していません |
警告 |
機器が動作不能 |
F1934 |
fltComputeBoardFailedSecure FuseValidation |
Intel PCH セキュア ヒューズの検証に失敗しました。Cisco TAC までお問い合わせください。 |
重大 |
設備不健康 |
F1935 |
fltBiosUnitFD0FailedSecurity 検証 |
BIOS FD0 の検証失敗BIOS を更新して再アクティブ化してください。 |
重大 |
BIOS-Image-Corrupted |
F0305 |
fltComputePhysicalInsufficiently Equipped |
Server [id] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adaptersServer [chassisId]/[slotId] (service profile: [assignedToDn]) has insufficient number of DIMMs, CPUs and/or adapters |
重大 |
機器が不十分 |
F0470 |
fltFirmwareUpdatableImageUnusable |
backup image is unusable. reason: [operStateQual] |
メジャー |
使用できない画像 |
F0744 |
fltPowerBudgetPowerCapReached コミット |
P-State lowered as consumption hit power cap for server [chassisId]/[slotId]P-State lowered as consumption hit power cap for server [id] |
[情報(Info)] |
消費電力が制限に達しました |
F1707 |
fltMgmtHealthStatusHealthCriticalIssue |
Intel ME ノード マネージャが異常または応答していません。 |
重大 |
設備不健康 |
F531 |
fltStorageRaidBatteryInoperable |
ストレージ RAID バッテリ %s は動作不能です。コントローラのバッテリを確認してください。 |
Minor |
機器が動作不能 |
F1003 |
fltStorageLocalDiskPatrolReadFailed |
%s ローカル ディスク %s PatrolRead に失敗しました。ストレージ ドライブ %s を確認してください |
警告 |
機器が動作不能 |
F1009 |
fltStorageVirtualDriveReconstruction 失敗(Failed) |
%s 仮想ドライブ %s の再構築に失敗しました。構成が一致しないため、再構築に失敗しました |
メジャー |
機器の劣化 |
F2012 |
fltStorageControllerPciEquipSlot 安全でない |
ストレージ コントローラ %s はクリティカルを保護できません: SPDM 通信が保護されていません |
メジャー |
安全でない機器 |