Este documento explica os campos de saída show lane client que são úteis para determinar por que um LAN Emulation Client (LEC) não aparecerá no estado operacional. Veja esta saída:
Gambrinus#show lane client LE Client ATM2/0/0 ELAN name: default Admin: up State: operational Client ID: 2 LEC up for 15 minutes 39 seconds ELAN ID: 1 Join Attempt: 691 Last Fail Reason: Control Direct VC being released HW Address: 0060.4750.8402 Type: ethernet Max Frame Size: 1516 ATM Address: 47.009181000000006047508401.006047508402.00 VCD rxFrames txFrames Type ATM Address 0 0 0 configure 47.009181000000006047508401.006047508405.00 256 1 10 direct 47.009181000000006047508401.000000000002.01 257 476 0 distribute 47.009181000000006047508401.000000000002.01 258 0 56 send 47.009181000000006047508401.000000000003.01 259 2 0 forward 47.009181000000006047508401.000000000003.01 263 1 18 data 47.009181000000006047508401.006047508402.00
O campo Admin indica se a interface ou subinterface está administrativamente desligada. O estado é definido de acordo com a especificação LANE. Se o campo Admin estiver inoperante, a primeira ação será ativar a interface. No caso da saída acima e em todo este documento, o campo Admin está ativo.
Não existem requisitos específicos para este documento.
Consulte as Convenções de Dicas Técnicas da Cisco para obter mais informações sobre convenções de documentos.
Se o LEC não estiver operacional, a única coisa a considerar é o último motivo de falha. Embora haja aproximadamente 30 possíveis razões de falha, quase todos os problemas mostram um destes últimos motivos de falha:
O problema está na camada física - verifique a qualidade do cabo. A interface provavelmente está no estado "Down, Down". Você pode verificar isso com o comando show interface atm. Verifique também a qualidade da placa. Uma boa maneira de fazer isso é fazer um loop de volta da interface fisicamente e verificar se a interface fica "Ativo, Ativo". Consulte Entendendo os Modos de Loopback em Cisco Routers para obter mais detalhes.
O sistema detectou que a configuração foi alterada. Nesse caso, você deve reiniciar o cliente. Desligue (ou não desligue) a subinterface para forçar o procedimento de união LEC. Assim que você fizer isso, o LEC se juntará à LAN emulada (ELAN) ou haverá um motivo de falha diferente.
Não é possível estabelecer a configuração Virtual Channel Connection (VCC) diretamente para o LAN Emulation Configuration Server (LECS). A ILMI (Intercalar Local Management Interface, Interface de gerenciamento local temporária) geralmente causa isso. Esse protocolo e seu VC associado devem ser ativados, pelo menos para obter o prefixo ATM. Se o ILMI não funcionar, você não tem conhecimento do prefixo e não pode estabelecer nenhum Circuito Virtual Comutado (SVCs). Isso pode ser verificado com o comando show lane default. A primeira saída mostra uma conexão ILMI funcionando corretamente:
Gambrinus#show lane default interface ATM2/0: LANE Client: 47.00918100000001604799FD01.0050A219F038.** LANE Server: 47.00918100000001604799FD01.0050A219F039.** LANE Bus: 47.00918100000001604799FD01.0050A219F03A.** LANE Config Server: 47.00918100000001604799FD01.0050A219F03B.00
Observação: ** é o byte do número da sub-interface em hexadecimal.
Se ILMI não estiver funcionando corretamente, "pontos" aparecerão no início de cada endereço. Em seguida, a saída é semelhante a esta:
Gambrinus#show lane default interface ATM1/0: LANE Client: ...00000C409820.** LANE Server: ...00000C409821.** LANE Bus: ...00000C409822.** LANE Config Server: ...00000C409823.00
Observação: ** é o byte do número da sub-interface em hexadecimal.
Se a saída não estiver OK, verifique se a Conexão Virtual Permanente (PVC - Permanent Virtual Connection) ILMI está bem definida. Consulte a Configuração dos PVCs de Sinalização e ILMI. Depois de concluir, você pode verificar o resultado com o comando show atm ilmi-status e ver o resultado em show lane default. Se o PVC ILMI tiver sido definido, ative debug atm ilmi para ver qual dispositivo (o dispositivo final ou o switch) está com defeito.
O endereço do LECS (LAN Emulation Configuration Server) está incorreto ou inacessível? Verifique a saída do show lane client para determinar se o endereço LECS enviado para o conhecido endereço ATM pode ser visto.
Se o LEC não pôde entrar em contato com o LECS, a saída será semelhante a esta:
Gambrinus#show lane client LE Client ATM2/0/0 ELAN name: default Admin: up State: initialState Client ID: unassigned Next join attempt in 1 seconds Join Attempt: 14 Last Fail Reason: Config VC being released HW Address: 0000.0c40.9820 Type: ethernet Max Frame Size: 1516 ATM Address: 47.00918100000001604799FD01.00000C409820.09 VCD rxFrames txFrames Type ATM Address 0 0 0 configure 47.007900000000000000000000.00A03E000001.00 0 0 0 direct 00.000000000000000000000000.000000000000.00 0 0 0 distribute 00.000000000000000000000000.000000000000.00 0 0 0 send 00.000000000000000000000000.000000000000.00 0 0 0 forward 00.000000000000000000000000.000000000000.00
Se o switch ATM remoto não for um dispositivo Cisco, lembre-se de que alguns fornecedores não suportam anúncios de endereços LECS através de ILMI. Nesse caso, você pode usar o endereço bem conhecido no LECS.
Se o endereço LECS for aprendido através de ILMI, verifique se os comandos atm lecs-address-default estão configurados corretamente nos switches ATM aos quais os LECs estão conectados. Tente codificar o endereço LECS neste LEC específico. Para obter um exemplo de configuração, consulte Configuração de Exemplo de Emulação de LAN.
Se você codificou o endereço ATM LECS em sua configuração ou se tiver um endereço ATM LECS válido que seja diferente do endereço conhecido na saída show lane client, vá para o dispositivo que hospeda o LECS. Use o comando show lane server para comparar o endereço LECS com o que você vê no cliente e verificar se o servidor está ligado.
O LECS recusa a ligação ao ELAN. Isso geralmente ocorre devido a um erro de configuração. O tipo ou nome da ELAN difere do que foi configurado no banco de dados.
Verifique sua configuração para o tipo (Ethernet/Token Ring) e o nome da ELAN na qual deseja participar. Conecte-se ao dispositivo que hospeda o LECS e verifique se o nome e o tipo do ELAN são idênticos. Lembre-se de que os nomes diferenciam maiúsculas e minúsculas.
Se o seu ELAN for restrito, verifique duas vezes se o endereço ATM do cliente é especificado no banco de dados LANE configurado no LECS.
Verifique se o Servidor de Emulação de LAN (LES) pode se conectar ao LECS. No dispositivo que hospeda o LES, use o comando show lane server e verifique se o LECS está conectado. Para se conectar ao LECS, o LES precisa das mesmas informações que um cliente simples precisaria.
Se você não conseguir se conectar ao LES, o LES estará inacessível ou configurado incorretamente.
A saída do show lane client geralmente se parece com:
Gambrinus#show lane client LE Client ATM2/0/0 ELAN name: default Admin: up State: initialState Client ID: unassigned Next join attempt in 7 seconds Join Attempt: 25 Last Fail Reason: Control Direct VC being released HW Address: 0000.0c40.9820 Type: ethernet Max Frame Size: 1516 ATM Address: 47.00918100000001604799FD01.00000C409820.09 VCD rxFrames txFrames Type ATM Address 0 0 0 configure 47.00918100000001604799FD01.00604799FD05.00 0 0 0 direct 47.00918100000001604799FD01.00604799FD03.09 0 0 0 distribute 00.000000000000000000000000.000000000000.00 0 0 0 send 00.000000000000000000000000.000000000000.00 0 0 0 forward 00.000000000000000000000000.000000000000.00
Se você codificou o endereço LES na configuração, verifique se o endereço na máquina que hospeda o LES é idêntico ao que você configurou.
O LES recusa a conexão.
Se o ELAN ao qual você deseja se conectar for restrito e se você se conectar diretamente ao LES (ignore o LECS), pode haver um problema de segurança. Se você configurou restrições, verifique a configuração do banco de dados LANE no LECS para garantir que ele inclua o endereço ATM do cliente que tenta se conectar.
Se você configurou um LEC e um LES na mesma subinterface e também especificou o endereço ATM para o LES com o comando lane server-atm-address, há a possibilidade de que o LEC tente entrar em contato com um LES de backup (que, em seguida, recusa a conexão). O motivo é que o LEC também usa o comando lane server-atm-address para decidir qual LES deve ser contatado. Em seguida, ele entrará em contato incondicional com o LES local que pode ser o backup no momento. A maneira fácil de corrigir isso é configurar o LES em uma subinterface diferente.
Revisão | Data de publicação | Comentários |
---|---|---|
1.0 |
05-Jun-2005 |
Versão inicial |