本文說明為什麼在配置中沒有入侵防禦系統(IPS)模組策略時,思科自適應安全裝置(ASA)可能會將流量傳送到嵌入式服務模組進行檢查。
A.
當配置了ASA時,可能會建立連線以將流量傳送到IPS模組進行檢查,並且該連線仍然處於活動狀態。
例如,具有ASA5515-IPS的客戶在策略對映中沒有配置策略以將流量傳送到軟體IPS模組;但是,流量從ASA到達模組。
當您在IPS上使用資料包顯示功能時,可以看到從ASA進入IPS的流量:
14:34:38.341927 IP 192.168.1.2.1719 > 192.168.10.39.1888: UDP, length 128
14:34:38.341992 IP 192.168.1.2.1719 > 192.168.10.39.1888: UDP, length 128
14:34:38.345031 IP 192.168.1.2.1719 > 192.168.110.39.1888: UDP, length 34
14:34:38.345068 IP 192.168.1.2.1719 > 192.168.110.39.1888: UDP, length 34
已清除IPS感應介面上的介面統計資訊,並接收資料包:
sensor# show interfaces portChannel
MAC statistics from interface PortChannel0/0
Interface function = Sensing interface
Description =
Media Type = backplane
Default Vlan = 0
InlineMode = Unpaired
Pair Status = N/A
Hardware Bypass Capable = No
Hardware Bypass Paired = N/A
Link Status = Up
Admin Enabled Status = Enabled
Link Speed = N/A
Link Duplex = N/A
Missed Packet Percentage = 0
Total Packets Received = 128
Total Bytes Received = 17904
Total Packets Transmitted = 128
Total Bytes Transmitted = 17904
問題的原因在於,在過去的某個時間,向ASA新增了一個配置以將流量傳送到IPS模組,而在ASA上刪除了IPS配置後,連線未清除。這種情況在持續傳遞流量的非TCP協定中很常見。
在ASA上,輸入show conn命令以確定您在IPS模組上看到的資料包是否具有連線條目。要檢視正常運行時間,請輸入show conn detail命令。為了確保連線不會重定向到IPS,您可能必須在ASA上輸入clear conn <address>命令以清除這些特定連線:
ASA# clear conn address 192.168.1.2
3 connection(s) deleted.
ASA#
修訂 | 發佈日期 | 意見 |
---|---|---|
1.0 |
07-Jun-2013 |
初始版本 |