Monitoring SD-Routing Alarms and Events
Information about Alarms and Events on SD-Routing Devices
SD-Routing Devices record, and store various events generated by control components and routers whenever a state or condition changes in the network. When an event is generated, the device reports it by sending a notification to the Cisco SD-WAN Manager. The SD-WAN manager processes them and runs a correlation algorithm using the correlating engine or alarms engine to determine whether an event indicates a problem, evaluates its severity, and determines if it warrants creating an alarm. While not all events escalate to alarms, every alarm originates from an event.
The SD-WAN Manager then sends a Remote Procedure Call (RPC) to retrieve these alarms once generated and the device replays those notifications to the Manager once the control connection is up. The system subsequently filters these notifications, correlates related events, and consolidates them by severity levels. These alarms not only assist in monitoring and troubleshooting the network but can also be used for further root cause analysis of the underlying issues.
Limitations for Alarms and Events on SD-Routing Devices
SD-Routing Devices can maintain a circular buffer for storing 256 alarms only.
Types of Alarms and Events
Cisco SD-WAN Manager groups the alarms and events based on its severity:
-
Critical (red) - Serious events that impair or shut down the operation of a network function.
-
Major (yellow) - Serious events that affect, but do not shut down, the operation of a network function.
-
Medium (orange) - Events that might impair the performance of a network function.
-
Minor (blue) - Events that might diminish the performance of a network function.
View and Manage Alarms on Cisco SD-WAN Manager
Use the alarms screen to display detailed information about alarms generated by control components and routers in the network. Navigate to
to open the Alarm window which displays alarms in graphical and tabular format along with the heatmap view of the alarm.When you click the Bell icon located at the top-right corner of the title bar, the Notifications pane appears. To filter or group alarms by Object, Severity, Type, and time (24 or 72 hours), click the Gear icon in this pane. By default, alarms are displayed for the last 24 hours.
View Alarm Details
To view alarm details such as alarm name, severity, and alarm description follow the below steps.
Customize Alarms Table
To view the probable cause of the alarm, impacted entities, and other details in the table displayed on the screen, click the Gear icon and select the preferred columns to display. The specifics of the available columns are listed below.
Parameters |
Description |
---|---|
Impacted entities |
Impacted entities specify the host used for network communication and identification within the IP address space of the local network. |
Impacted entities details |
Impacted entity details specifies the network component on the host with the IP address and the interface. |
Severity |
The severity indicates the seriousness of the alarm. There are four types of severity: critical, major, medium, minor. |
Object |
Alarms are grouped based on either the device or site for which the alarm is generated. |
Alarm Type |
Indicates that the alarms are categorized according to their type. |
Message |
Specifies the description of the alarm. |
Related Events |
Displays events, related to an alarm, that occurs around the time the alarm is generated. |
Date and Time |
Displays the Date and Time when the alarm was generated. |
Cleared Date and Time |
Displays the Date and Time when the alarm was cleared. |
Action |
Displays an ellipsis, which, when clicked, opens a menu providing you with detailed information about the alarm. |
Set Alarm Time Range
Click on the 24 Hours icon at the top-left of the screen to select the Time Range and customize the range by selecting the preferred start day, time and end date, time. By default, alarms and events are displayed for the last 24 hours.
Setup Advanced Alarm Filters
You can use the following steps to filter alarms and view details of a specific/multiple alarms
Procedure
Step 1 | Click Advanced Filter and select Site or Device for which you want to view alarms and choose the following fields.
| ||||||||
Step 2 | Click Apply Filters to view alarms that match the filter criteria. |
Export Alarm Details
Procedure
Step 1 | Click Export to export data for all alarms to a file in CSV format. Cisco SD-WAN Manager downloads data from the alarms table to the default download location of your browser. The data is downloaded as a CSV file with the name alarms-mm-dd-yyyy.csv. (Here mm, dd, and yyyy refer to the month, day, and year the file was downloaded). |
Step 2 | Open the downloaded file to view alarm details. |
Configure Email Notifications for Alarms
You can configure Cisco SD-WAN Manager to enable, send, edit and delete email notifications.
Enable Email Notifications
Configure SMTP and email recipient parameters to enable email notifications for alarms. Follow these steps to complete the configuration.
Procedure
Step 1 | From the Cisco SD-WAN Manager menu, choose . |
Step 2 | In Alarm Notifications, choose Enabled. |
Step 3 | Check the Email Settings check box. |
Step 4 | Choose the security level for sending the email notifications. The security level can be None, SSL, or TLS. |
Step 5 | In the SMTP Server field, enter the name or the IP address of the SMTP server to receive the email notifications. |
Step 6 | In the SMTP Port field, enter the SMTP port number. For no security, the default port is 25; for SSL it is 465; and for TLS it is 587. |
Step 7 | In the From address field, enter the email address to include as the sender in email notifications. |
Step 8 | In the Reply to address field, enter the email address to include in the Reply-To field of the email. This address can be a no-reply address, such as noreply@cisco.com. |
Step 9 | Check the Use SMTP Authentication check box to enable SMTP authentication to the SMTP server. |
Step 10 | Enter the username and password to use for SMTP authentication. The default user email suffix is appended to the username. Note, the password that you type is hidden. |
Step 11 | Click Save |
Send Email Notifications
To send email notifications, click Add Alarm Notification or click the bell icon at the top-right corner of the title bar and follow the below steps.
Before you begin
Ensure that Email Notifications are enabled under Alarm Notifications is enabled and, Email Settings check box is checked. For more details, see Enable Email Notifications.
, check whetherProcedure
Step 1 | In the Notification Name field, enter a name for the email notification. The name can be up to 128 characters and can contain only alphanumeric characters. |
Step 2 | In the Object Type field, select Site or Device for which you want to view alarms. |
Step 3 | In the Object List field, choose either Site ID or Device for which you want to view alarms. You can choose more than one site or device |
Step 4 | In the Severity field, choose one or more alarm severity levels from the drop-down list. |
Step 5 | In the Type field, choose one or more alarms. |
Step 6 | In the Delivery Method field, enter the following: |
Step 7 | Click Add Notification. |
Edit Email Notifications
To edit email notifications, navigate toAlarm Notifications to view a list of configured notifications. Select the Edit icon next to the preferred notification and click Update when done.
. ClickDelete Email Notifications
To delete email notifications, navigate to Alarm Notifications to view a list of configured notifications. Choose the Trash Bin icon next to the preferred notification and Click OK in the dialog box to confirm.
. ClickView and Manage Events on Cisco SD-WAN Manager
Use the events screen to display detailed information about events generated by SD-Routing Devices. Navigate to
to open the Event window which displays events in graphical and tabular format along with the heatmap view of the alarm.View Event Details
To view event details such as event time, severity, and hostname follow the below steps.
Customize Events Table
To view the component, hostname and other details in the table displayed on the screen, click the Gear icon and select the preferred columns to display. The specifics of the available columns are listed below.
Parameters |
Description |
---|---|
Message |
Specifies the description of the alarm. |
Event Time |
Displays the time of the event. |
Hostname |
Specifies the name of the host. |
System IP |
Displays the system IP of the devices. |
Name |
Specifies the event name. |
Severity |
Indicates the seriousness of the event. There are three types of event severity: critical, major, minor. |
Component |
Specifies the components that caused the event. |
Details |
Displays the event details. |
Action |
Displays an ellipsis, which, when clicked, opens a menu providing you with detailed information about the alarm. |
Set Event Time Range
Click on the 24 Hours icon at the top-left of the screen to select the Time Range and customize the range by selecting the preferred start day, time and end date, time. By default, events are displayed for the last 24 hours.
Setup Advanced Event Filters
You can use the following steps to filter Events and view details of a specific/multiple events.
Procedure
Step 1 | Click Advanced Filter and select Site or Device for which you want to view events and choose the following fields.
| ||||||||
Step 2 | Click Apply Filters to view events that match the filter criteria. |
Export Event Details
Procedure
Step 1 | Click Export to export data for all events to a file in CSV format. Cisco SD-WAN Manager downloads data from the events table to the default download location of your browser. The data is downloaded as a CSV file with the name alarms-mm-dd-yyyy.csv. (Here mm, dd, and yyyy refer to the month, day, and year the file was downloaded). |
Step 2 | Open the downloaded file to view event details. |