Cable and Port Specifications

This appendix provides cable and port specifications for the Fabric Extender (FEX) and includes the following sections:

Supported Power Cords and Plugs

Each power supply has a separate power cord. Standard power cords or jumper power cords are available for connection to a power distribution unit that has IEC 60320 C19 outlet receptacles. The jumper power cords, for use in cabinets, are available as an optional alternative to the standard power cords.

note.gif

Noteblank.gif For N2200-PDC-350W-B or N2200-PDC-400W DC power supplies:

- The terminal block that is used (2-position) accepts wire sizes 22AWG-14AWG.

- For the maximum input current of approximately 15A, a 18AWG wire meets minimum requirements. 16AWG adds some margin, and this is recommended.

- There is no earth ground connection on this input terminal block, thus the earth grounding is provided by the system being grounded.


Power Cords

The standard power cords have an IEC C19 connector on the end that plugs into the device. The optional jumper power cords have an IEC C19 connector on the end that plugs into the device and an IEC C20 connector on the end that plugs into an IEC C19 outlet receptacle.

note.gif

Noteblank.gif Only the regular power cords or jumper power cords provided with the device are supported.


note.gif

Noteblank.gif If you do not order the optional power cord with the system, you are responsible for selecting the appropriate power cord for the product. Using a non-compatible power cord with this product may result in electrical safety hazard. Orders delivered to Argentina, Brazil, and Japan must have the appropriate power cord ordered with the system.


Table C-1 lists the AC power cords for the Cisco Nexus Fabric Extender and provides their lengths in feet and meters.

 

Table C-1 AC Power Cords for the Cisco Nexus Fabric Extender

Description
Length
Power Cord Reference Illustration
Feet
Meters

CAB-250V-10A-AR
Power Cord, 250 VAC 10 A IRAM 2073 Plug
Argentina

8.2

2.5

Figure C-1

CAB-9K10A-AU
250 VAC 10 A 3112 Plug,
Australia

8.2

2.5

Figure C-2

CAB-250V-10A-CN
Power Cord, 250 VAC 10 A GB 2009 Plug
China

8.2

2.5

Figure C-3

CAB-9K10A-EU
Power Cord, 250 VAC 10 A M 2511 Plug
Europe

8.2

2.5

Figure C-4

CAB-250V-10A-ID
Power Cord, 250 VAC 16A EL-208 Plug
South Africa, United Arab Emirates, India

8.2

2.5

Figure C-5

CAB-250V-10A-IS
Power Cord, 250 VAC 10 A SI32 Plug
Israel

8.2

2.5

Figure C-6

CAB-9K10A-IT
Power Cord, 250 VAC 10 A CEI 23-16 Plug
Italy

8.2

2.5

Figure C-7

CAB-9K10A-SW
Power Cord, 250 VAC 10 A MP232 Plug
Switzerland

8.2

2.5

Figure C-8

CAB-9K10A-UK
Power Cord, 250 VAC 10 A BS1363 Plug (13 A fuse)
United Kingdom

8.2

2.5

Figure C-9

CAB-AC-250V/13A
Power Cord, 250 VAC 13 A IEC60320 Plug
North America

6.6

2.0

Figure C-10

CAB-N5K6A-NA
Power Cord, 250 VAC 13 A NEMA 6-15 Plug,
North America

8.2

2.5

Figure C-11

CAB-9K12A-NA
Power Cord, 125VAC 15A NEMA 5-15 Plug, North America

8.2

2.5

Figure C-12

CAB-C13-CBN
Cabinet Jumper Power Cord, 250 VAC 16A, C14-C13 Connectors

2.25

0.686

Figure C-13

CAB-IND-10A(=)
10A Power cable for India

8.2

2.5

Figure C-14

CAB-C13-CBN
Cabinet Jumper Power Cord, 250 VAC 16A, C14-C13 Connector

2.25

0.686

Figure C-15

CAB-C13-C14-JMPR
Cabinet Jumper Power Cord, 250 VAC 10 A, C14-C15 Connector

2.2

0.7

Figure C-16

CAB-C13-C14-2M(=)
Power Cord Jumper, C13-C14 Connectors, 2 Meter Length

6.6

2.0

 

CAB-C13-C14-AC(=)
Power Cord Jumper, C13-C14 Connectors, 3 Meter Length

 

3.0

 

Figure C-1 CAB-250V-10A-AR

 

186571.eps

Figure C-2 CAB-9K10A-AU

 

186581.eps

Figure C-3 CAB-250V-10A-CN

 

186573.eps

Figure C-4 CAB-9K10A-EU

 

186576.eps

Figure C-5 CAB-250V-10A-ID

 

187490.eps

Figure C-6 CAB-250V-10A-IS

 

186574.eps

Figure C-7 CAB-9K10A-IT

 

186575.eps

Figure C-8 CAB-9K10A-SW

 

186578.eps

Figure C-9 CAB-9K10A-UK

 

186580.eps

Figure C-10 CAB-AC-250V/13A

 

186568.eps

Figure C-11 CAB-N5K6A-NA

 

186570.eps

Figure C-12 CAB-9K12A-NA

 

192260.eps

Figure C-13 CAB-C13-CBN

 

186569.eps

Figure C-14 CAB-IND-10A

 

192259.eps

Figure C-15 CAB-C13-CBN

 

192532.eps

Table C-2 lists the AC power cords for the Cisco Nexus 2232TM.

 

Table C-2 AC Power Cords for the Cisco Nexus 2232TM

Power Cords
Description

CAB-3KX-AC=

AC power card for North America

CAB-3KX-AC-AP=

AC power card for Australia

CAB-3KX-AC-AR=

AC power card for Argentina

CAB-3KX-AC-SW=

AC power card for Switzerland

CAB-3KX-AC-UK=

AC power card for United Kingdom

CAB-3KX-AC-JP=

AC power card for Japan

CAB-3KX-AC-EU=

AC power card for Europe

CAB-3KX-AC-IT=

AC power card for Italy

CAB-3KX-AC-IN=

AC power card for India

CAB-3KX-AC-CN=

AC power card for China

CAB-3KX-AC-DN=

AC power card for Denmark

CAB-3KX-AC-IS=

AC power card for Israel

Table C-3 lists the power cables for the HVAC/HVDC power supplies (NXA-PHV-500W and NXA-PHV-500W-B).

 

Table C-3 Power Cable Specifications for HVAC/HVDC Power Supplies

Power Type
Power Cord
Description

HVAC

CAB-HVAC-SD-0.6M

2-foot (0.6 m) cable with Saf-D-Grid and SD connectors (LS-25 straight)

HVAC

CAB-HVAC-C14-2M

6.6-foot (2.0 m) cable with Saf-D-Grid and C14 connector (use for up to 240 V)

HVAC

CAB-HVAC-RT-0.6M

2-foot (0.6 m) cable with Saf-D-Grid and RT connector (LS-25 right angle)

HVDC

CAB-HVDC-3T-2M

6.6-foot (2.0 m) cable with Saf-D-Grid and three terminal connectors

Jumper Power Cord

Figure C-16 shows the plug connector on the optional jumper power cord for the Cisco Nexus Fabric Extender. The plug plugs into the Cisco Nexus Fabric Extender power supply, while the connector plugs into the receptacle of a power distribution unit for a cabinet.

Figure C-16 CAB-C13-C14-JMPR, Jumper Power Cord

 

186569.eps