The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This chapter describes how to configure a Cisco Nexus 2000 Series Fabric Extender using a parent Cisco Nexus 7000 Series device and includes the following sections:
This section describes how to configure the Fabric Extender.
You can install and manage the Fabric Extender feature set.
1.
Installing the Fabric Extender Feature Set
2.
Enabling the Fabric Extender Feature Set
3.
(Optional) Disallowing the Fabric Extender Feature Set
Step 1 | Installing the Fabric Extender Feature Set |
Step 2 | Enabling the Fabric Extender Feature Set |
Step 3 | (Optional)Disallowing the Fabric Extender Feature Set |
Note | You must enable the Fabric Extender feature set in the default virtual device context (VDC). Once enabled in the default VDC, the FEX can belong to any VDC and can be configured from those VDCs. A single Fabric Extender belongs exclusively to a single VDC. |
Ensure that you are in the default VDC.
Ensure that you have disabled the Intrusion Detection System (IDS) reserved addresses check (it is disabled by default). Use the show hardware ip verify command and look for the string "address reserved" in the output. If the IDS reserved addresses check is enabled, disable it with the no hardware ip verify address reserved command.
1.
configure terminal
2.
install feature-set fex
3.
exit
You can enable the installed Fabric Extender feature set in any VDC on the device.
Ensure that you have installed the Fabric Extender feature set in the default VDC.
Ensure that you are in the correct VDC or use the switchto vdc command.
1.
configure terminal
2.
feature-set fex
3.
exit
By default, when you install the Fabric Extender feature set, it is allowed in all VDCs. You can disallow the installed Fabric Extender feature set in a specific VDC on the device.
Ensure that you have installed the feature set in the default VDC.
Ensure that you have not enabled the feature set in the specified VDC.
1.
configure terminal
2.
vdc vdc_ID
3.
no allow feature-set fex
4.
end
Command or Action | Purpose | |
---|---|---|
Step 1 | configure terminal Example: switch# configure terminal switch(config)# | Enters global configuration mode. |
Step 2 | vdc vdc_ID Example: switch(config)# vdc 1 | Specifies a VDC and enters VDC configuration mode. |
Step 3 |
no allow feature-set fex Example: switch(config-vdc)# no allow feature-set fex |
Disallows the feature set in the VDC. You cannot disallow a feature set that is enabled in the specified VDC. By default, the installed Fabric Extender feature set is allowed in all VDCs on the device. You can disallow a feature set in a specific VDC. Subsequently, you can change the status back to allowed with the allow feature-set fex command. |
Step 4 | end Example: switch(config-vdc)# end switch# | Exits VDC configuration mode and returns to EXEC mode. |
A FEX is connected to its parent device through a port channel. By default, the parent device does not allow the attached Fabric Extender to connect until it has been assigned a FEX number and is associated with the connected interface.
Note | You must have installed and enabled the Fabric Extender features with the install feature-set fex and feature-set fex commands before you can configure and use a Fabric Extender that is connected to the parent switch. |
Note | Associating a Fabric Extender to a fabric interface enables the specified port to operate only in shared rate-mode. The port does not support dedicated rate-mode when associated with a Fabric Extender. |
Ensure that you have installed and enabled the Fabric Extender feature set.
1.
configure terminal
2.
interface port-channel
channel
3.
switchport
4.
switchport mode
fex-fabric
5.
fex associate
FEX-number
6.
(Optional)
show interface
port-channel
channel
fex-intf
Command or Action | Purpose | |
---|---|---|
Step 1 |
configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. |
Step 2 |
interface port-channel
channel
Example: switch(config)# interface port-channel 4 switch(config-if)# |
Specifies a port channel to configure. |
Step 3 | switchport
Example: switch(config-if)# switchport |
Sets the interface as a Layer 2 switching port. |
Step 4 |
switchport mode
fex-fabric
Example: switch(config-if)# switchport mode fex-fabric |
Sets the port channel to support an external Fabric Extender. |
Step 5 |
fex associate
FEX-number
Example: switch(config-if)# fex associate 101 |
Associates a FEX number to the Fabric Extender unit attached to the interface. The range is from 101 to 199. |
Step 6 |
show interface
port-channel
channel
fex-intf
Example: switch# show interface port-channel 4 fex-intf | (Optional)
Displays the association of a Fabric Extender to a port channel interface. |
This example shows how to associate the Fabric Extender to a port channel interface on the parent device:
switch# configure terminal switch(config)# interface ethernet 1/28 switch(config-if)# channel-group 4 switch(config-if)# no shutdown switch(config-if)# exit switch(config)# interface ethernet 1/29 switch(config-if)# channel-group 4 switch(config-if)# no shutdown switch(config-if)# exit switch(config)# interface ethernet 1/30 switch(config-if)# channel-group 4 switch(config-if)# no shutdown switch(config-if)# exit switch(config)# interface ethernet 1/31 switch(config-if)# channel-group 4 switch(config-if)# no shutdown switch(config-if)# exit switch(config)# interface port-channel 4 switch(config-if)# switchport switch(config-if)# switchport mode fex-fabric switch(config-if)# fex associate 101
Tip | As a best practice, only enter the fex associate command from the port channel interface, not from the physical interface. |
Note | When adding physical interfaces to port channels, all configurations on the port channel and physical interface must match. |
This example shows how to display the association of the Fabric Extender and the parent device:
switch# show interface port-channel 4 fex-intf Fabric FEX Interface Interfaces --------------------------------------------------- Po4 Eth101/1/48 Eth101/1/47 Eth101/1/46 Eth101/1/45 Eth101/1/44 Eth101/1/43 Eth101/1/42 Eth101/1/41 Eth101/1/40 Eth101/1/39 Eth101/1/38 Eth101/1/37 Eth101/1/36 Eth101/1/35 Eth101/1/34 Eth101/1/33 Eth101/1/32 Eth101/1/31 Eth101/1/30 Eth101/1/29 Eth101/1/28 Eth101/1/27 Eth101/1/26 Eth101/1/25 Eth101/1/24 Eth101/1/23 Eth101/1/22 Eth101/1/21 Eth101/1/20 Eth101/1/19 Eth101/1/18 Eth101/1/17 Eth101/1/16 Eth101/1/15 Eth101/1/14 Eth101/1/13 Eth101/1/12 Eth101/1/11 Eth101/1/10 Eth101/1/9 Eth101/1/8 Eth101/1/7 Eth101/1/6 Eth101/1/5 Eth101/1/4 Eth101/1/3 Eth101/1/2 Eth101/1/1
Ensure that you have installed and enabled the Fabric Extender feature set.
Ensure that you are in the correct VDC (or use the switchto vdc command).
1.
configure terminal
2.
interface {ethernet
slot/port |
port-channel
channel}
3.
no fex associate
Command or Action | Purpose | |
---|---|---|
Step 1 |
configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. |
Step 2 |
interface {ethernet
slot/port |
port-channel
channel}
Example: switch(config)# interface port-channel 4 switch(config-if)# |
Specifies the interface to configure. The interface can be an Ethernet interface or a port channel. |
Step 3 |
no fex associate
Example: switch(config-if)# no fex associate |
Disassociates the Fabric Extender unit attached to the interface. |
You can associate the Fabric Extender to an F2-Series module.
Ensure that you have installed and enabled the Fabric Extender feature set.
Note | F2-Series modules are supported only by the following FEX devices: |
Note | Each port in the ASIC has an index. Allow only ports with similar indices across ASICs to be added to a port channel. For example, if port 1 has an index of 1 and port 2 has an index of 2, the following ports are supported and not supported:
A set of ports from an ASIC that has an index sub-set S, such as {1,2,4}, is allowed to be added to a port channel only if the port channel has an equivalent or an empty set. |
1.
vdc switch
2.
limit-resource module-type f2
3.
interface ethernet mod-number port-range
4.
allocate interface ethernet slot-port
5.
switchport mode fex -fabric
6.
fex associate FEX chassis number
7.
channel-group port-channel number
8.
no shutdown
9.
int po port-channel number
10.
no shutdown
Command or Action | Purpose | |
---|---|---|
Step 1 |
vdc switch Example: switch(config)# vdc switch |
Specifies the VDC. |
Step 2 | limit-resource module-type f2 Example: switch(config)# limit-resource module-type f2 | Specifies the module type. |
Step 3 | interface ethernet mod-number port-range Example: switch(config)# interface ethernet 1/1 | Specifies the interface. |
Step 4 | allocate interface ethernet slot-port Example: switch(config)# allocate interface ethernet 1 | Allocates the F2-Series interfaces to VDC. |
Step 5 | switchport mode fex -fabric Example: switch(config-if)# switchport mode fex -fabric | Specifies the FEX. |
Step 6 | fex associate FEX chassis number Example: switch(config-if)# fex associate 101 | Specifies the chassis. |
Step 7 | channel-group port-channel number Example: switch(config-if)# channel-group 1 | Specifies the port channel number. |
Step 8 | no shutdown Example: switch(config-if)# no shutdown | Brings up the port. |
Step 9 | int po port-channel number Example: switch(config-if)# int po 1 | Specifies the port channel. |
Step 10 | no shutdown Example: switch(config-if)# no shutdown | Brings up the port channel. |
You can configure global features on the Fabric Extender.
Ensure that you have enabled the Fabric Extender feature set.
1.
configure terminal
2.
fex
FEX-number
3.
(Optional)
description
desc
4.
(Optional)
no description
5.
(Optional) type
FEX-type
6.
(Optional) no type
7.
(Optional)
serial
serial
8.
(Optional)
no serial
Command or Action | Purpose | |||
---|---|---|---|---|
Step 1 |
configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. | ||
Step 2 |
fex
FEX-number
Example: switch(config)# fex 101 switch(config-fex)# |
Enters FEX configuration mode for the specified Fabric Extender. The range of the FEX-number is from 101 to 199. | ||
Step 3 |
description
desc
Example: switch(config-fex)# description Rack7A-N2K | (Optional)
Specifies the description. The default is the string FEXxxxx where xxxx is the FEX number. If the FEX number is 123, the description is FEX0123. | ||
Step 4 |
no description
Example: switch(config-fex)# no description | (Optional)
Deletes the description. | ||
Step 5 | type
FEX-type
Example: switch(config-fex)# type N2248T | (Optional)
Specifies the type of Fabric Extender. The FEX-type is one of the following:
The parent Cisco Nexus Series device remembers the type of the Fabric Extender in its binary configuration. When this feature is configured, the Fabric Extender is allowed only to come online if its type matches the configured FEX type. | ||
Step 6 | no type
Example: switch(config-fex)# no type | (Optional)
Deletes the FEX type. When a Fabric Extender is connected to the fabric interfaces and does not match the configured type that is saved in the binary configuration on the parent switch, all configurations for all interfaces on the Fabric Extender are deleted. | ||
Step 7 |
serial
serial
Example: switch(config-fex)# serial JAF1339BDSK | (Optional)
Defines a serial number string. If this command is configured, a switch allows the corresponding chassis ID to associate (using the fex associate command) only if the Fabric Extender reports a matching serial number string.
| ||
Step 8 |
no serial
Example: switch(config-fex)# no serial | (Optional)
Deletes the serial number string. |
For Cisco NX-OS Release 6.2(2) and later releases, the Cisco Fabric Extenders support Layer 3 protocol adjacencies on host interfaces (HIFs) and DSCP to queue mapping. Before Cisco NX-OS Release 6.2(2), you can configure a Fabric Extender (FEX) port as a Layer 3 interface for host connectivity, but not for routing. See the Configuring the Cisco Nexus 2000 Series Fabric Extender for more information about fabric extenders.
1.
configure terminal
2.
hardware qos dscp-to-queue ingress module type
{all |
f-series |
m-series}
3.
(Optional) show hardware qos dscp-to-queue ingress
4.
(Optional) copy running-config startup-config
Command or Action | Purpose | |
---|---|---|
Step 1 |
configure terminal
Example: switch(config)# configure terminal |
Enters global configuration mode. |
Step 2 | hardware qos dscp-to-queue ingress module type
{all |
f-series |
m-series}
Example: switch(config)# hardware qos dscp-to-queue ingress module type m-series |
Enables the dscp-to-queue mapping on the specified module(s). |
Step 3 | show hardware qos dscp-to-queue ingress
Example: switch(config)# show hardware qos dscp-to-queue ingress | (Optional)
Displays information about the status of dscp-to-queue mapping in ingress direction. |
Step 4 | copy running-config startup-config
Example: switch(config)# copy running-config startup-config | (Optional)
Saves the running configuration to the startup configuration. |
This section contains examples of FEX configurations.
This example shows how to configure a Fabric Extender with a Layer 3 host interface (at the interface level, subinterface level, port channel level, and port channel subinterface level):
Layer 3 Configuration | Layer 3 Subinterface Configuration |
---|---|
config t interface ethernet 101/1/1 no switchport ip address 192.0.1.1/24 Mtu 9000 no shutdown |
config t interface ethernet 101/1/1.12 ip address 192.0.2.1/24 encapsulation dot1Q 12 mtu 850 no shutdown |
Layer 3 Host Interface Port Channel Configuration | Layer 3 Host Interface Port Channel Subinterface Configuration |
---|---|
config t interface ethernet 101/1/1-2 no switchport channel-group 12 no shutdown interface port-channel 12 ip address 192.0.3.1/24 mtu 2000 no shutdown |
config t interface ethernet 101/1/1-2 no switchport channel-group 12 no shutdown interface port-channel 12.14 ip address 192.0.4.1/24 encapsulation dot1Q 14 mtu 1700 no shutdown |
Note | The VLAN used in the Layer 3 host interface (HIF) or host interface port channel (HIFPC) subinterface has only local significance to its parent interface. The same VLAN ID can be reused between Layer 3 subinterfaces in the same switch or VDC. |
This example shows how to configure a host vPC with a FEX (host vPC attached to two different FEXs):
Note | The switchport trunk allowed vlan vlan-list command is not supported on FEX fabric interfaces. |
Switch 1 Configuration | Switch 2 Configuration |
---|---|
config t feature lacp int e101/1/1-2 channel-group 12 mode active no shutdown int port-channel10 switchport switchport mode trunk switchport trunk allowed vlan 1-20 vpc 10 |
config t feature lacp int e101/1/1-2 channel-group 12 mode active no shutdown int port-channel10 switchport switchport mode trunk switchport trunk allowed vlan 1-20 vpc 10 |
Note | Cisco Nexus 7000 Series switches do not support dual-homing. |
Enable FabricPath on each switch.
Configure the interfaces that you want to designate as FabricPath interfaces.
Set the STP priority device to 8192 on all FabricPath Layer 2 gateway devices.
(Optional) Set the STP domain ID for each of the separate STP domains that are connected to the FabricPath network.
(Optional) Configure a FEX switch ID.
To configure FabricPath interfaces, follow these steps:
(Optional) Enable FabricPath on each switch.
switch# config terminal switch(config)# feature fabricpath switch(config-lldp)# exit switch(config)#
After you enable FabricPath on the switch, configure the specified interface as FabricPath interfaces.
switch(config)# interface ethernet 1/2 switch(config-if)# switchport mode fabricpath switch(config-if)# exit switch(config)#
Configure the STP priority for all Rapid PVST+ VLANs as 8192.
switch# config terminal switch(config)# spanning-tree vlan 11-20 priority 8192 switch(config)#
Configure the STP priority for all MST instances as 8192.
switch# config terminal switch(config)# spanning-tree mst 1-5 priority 8192 switch(config)#
(Optional) Configure the STP domain ID on each FabricPath Layer 2 gateway switch attached to the FabricPath network.
switch# config terminal switch(config)# spanning-tree domain 5 switch(config)
(Optional) Configure the FEX switch ID.
Note | See the Cisco Nexus 7000 Series NX-OS Interfaces Configuration Guide for information on configuring FEX. |
Note | FEX VPC+ configurations are supported only on F2-Series modules. |
If you are setting up an initial FEX VPC+ configuration on an F2-Series module, follow these steps:
In the VPC domain configuration mode, enable partial DF mode with the fabricpath multicast load-balance command.
If disabled, enable TRILL style mac-address learning with the mac address-table core-port-learning command.
In the VPC domain configuration mode, configure the emulated switch ID with the fabricpath switchid switchid# command.
On each of the VPC/VPC+ peer link interfaces in interface configuration mode, enter theswitchport mode fabricpath command.
On each VPC/VPC+ peer link port channel, enter the VPC peer-link command.
Configure the VPC ID with the vpc vpcid command.
If you are changing an existing FEX VPC configuration to a FEX VPC+ configuration on an F2-Series module, follow these steps:
In the VPC domain configuration mode, enable partial DF mode with the fabricpath multicast load-balance command.
If disabled, enable trill style mac-address learning with the mac address-table core-port-learning command.
In the VPC domain configuration mode, configure the emulated switch ID with the fabricpath switchid switchid# command.
Copy the configuration.
switch(config)# copy running-config startup-config switch(config)#
The following sample output from the show hardware qos dscp-to-queue ingress command displays the status of DSCP-to-queue mapping enabled in ingress direction on F-series modules:
Switch# show hardware qos dscp-to-queue ingress status: Enabled module_type : f-series
This section describes how to display the configuration of the Fabric Extender and verify the chassis hardware status.
Use the following commands to display configuration information about the defined interfaces on a Fabric Extender:
Command or Action |
Purpose |
---|---|
show fex [FEX-number] [detail] | Displays information about a specific Fabric Extender or all attached units. |
show interface type number fex-intf | Displays the Fabric Extender ports that are pinned to a specific switch interface. |
show interface fex-fabric | Displays the switch interfaces that have detected a Fabric Extender uplink. |
show interface ethernet number transceiver [fex-fabric] | Displays the SFP+ transceiver and diagnostic optical monitoring (DOM) information for the Fabric Extender uplinks. |
show feature-set | Displays the status of the feature sets on the device. |
This example shows how to display all the attached Fabric Extender units:
switch# show fex FEX FEX FEX FEX Number Description State Model Serial ------------------------------------------------------------------------ 101 FEX0101 Online N2K-C2248TP-1GE JAF1418AARL
This example shows how to display the detailed status of a specific Fabric Extender:
switch# show fex 101 detail FEX: 101 Description: FEX0101 state: Online FEX version: 5.1(1) [Switch version: 5.1(1)] FEX Interim version: 5.1(0.159.6) Switch Interim version: 5.1(1) Extender Model: N2K-C2248TP-1GE, Extender Serial: JAF1418AARL Part No: 73-12748-05 Card Id: 99, Mac Addr: 54:75:d0:a9:49:42, Num Macs: 64 Module Sw Gen: 21 [Switch Sw Gen: 21] pinning-mode: static Max-links: 1 Fabric port for control traffic: Po101 Fabric interface state: Po101 - Interface Up. State: Active Eth2/1 - Interface Up. State: Active Eth2/2 - Interface Up. State: Active Eth4/1 - Interface Up. State: Active Eth4/2 - Interface Up. State: Active Fex Port State Fabric Port Primary Fabric Eth101/1/1 Up Po101 Po101 Eth101/1/2 Up Po101 Po101 Eth101/1/3 Down Po101 Po101 Eth101/1/4 Down Po101 Po101 Eth101/1/5 Down Po101 Po101 Eth101/1/6 Down Po101 Po101 Eth101/1/7 Down Po101 Po101 Eth101/1/8 Down Po101 Po101 Eth101/1/9 Down Po101 Po101 Eth101/1/10 Down Po101 Po101 Eth101/1/11 Down Po101 Po101 Eth101/1/12 Down Po101 Po101 Eth101/1/13 Down Po101 Po101 Eth101/1/14 Down Po101 Po101 Eth101/1/15 Down Po101 Po101 Eth101/1/16 Down Po101 Po101 Eth101/1/17 Down Po101 Po101 Eth101/1/18 Down Po101 Po101 Eth101/1/19 Down Po101 Po101 Eth101/1/20 Down Po101 Po101 Eth101/1/21 Down Po101 Po101 Eth101/1/22 Down Po101 Po101 Eth101/1/23 Down Po101 Po101 Eth101/1/24 Down Po101 Po101 Eth101/1/25 Down Po101 Po101 Eth101/1/26 Down Po101 Po101 Eth101/1/27 Down Po101 Po101 Eth101/1/28 Down Po101 Po101 Eth101/1/29 Down Po101 Po101 Eth101/1/30 Down Po101 Po101 Eth101/1/31 Down Po101 Po101 Eth101/1/32 Down Po101 Po101 Eth101/1/33 Down Po101 Po101 Eth101/1/34 Down Po101 Po101 Eth101/1/35 Down Po101 Po101 Eth101/1/36 Down Po101 Po101 Eth101/1/37 Down Po101 Po101 Eth101/1/38 Down Po101 Po101 Eth101/1/39 Down Po101 Po101 Eth101/1/40 Down Po101 Po101 Eth101/1/41 Down Po101 Po101 Eth101/1/42 Down Po101 Po101 Eth101/1/43 Down Po101 Po101 Eth101/1/44 Down Po101 Po101 Eth101/1/45 Down Po101 Po101 Eth101/1/46 Down Po101 Po101 Eth101/1/47 Down Po101 Po101 Eth101/1/48 Down Po101 Po101 Logs: 09/21/2010 21:14:26.843850: Module register received 09/21/2010 21:14:26.845778: Registration response sent 09/21/2010 21:14:27.663073: Module Online Sequence 09/21/2010 21:14:30.191121: Module Online
This example shows how to display the Fabric Extender interfaces pinned to a specific switch interface:
switch# show interface port-channel 101 fex-intf Fabric FEX Interface Interfaces --------------------------------------------------- Po101 Eth101/1/2 Eth101/1/1
This example shows how to display the switch interfaces that are connected to a Fabric Extender uplink:
switch# show interface fex-fabric Fabric Fabric Fex FEX Fex Port Port State Uplink Model Serial --------------------------------------------------------------- 101 Eth2/1 Active 1 N2K-C2248TP-1GE JAF1418AARL 101 Eth2/2 Active 2 N2K-C2248TP-1GE JAF1418AARL 101 Eth4/1 Active 3 N2K-C2248TP-1GE JAF1418AARL 101 Eth4/2 Active 4 N2K-C2248TP-1GE JAF1418AARL
This example shows how to display the SFP+ transceiver and diagnostic optical monitoring (DOM) information for Fabric Extender uplinks for an SFP+ transceiver that is plugged into the parent switch interface:
switch# show interface ethernet 1/40 transceiver Ethernet1/40 sfp is present name is CISCO-MOLEX INC part number is 74752-9026 revision is A0 serial number is MOC13321057 nominal bitrate is 12000 MBits/sec Link length supported for copper is 3 m(s) cisco id is -- cisco extended id number is 4
This example shows how to display the SFP+ transceiver and DOM information for Fabric Extender uplinks for an SFP+ transceiver that is plugged into the uplink port on the Fabric Extender:
switch# show interface ethernet 1/40 transceiver fex-fabric Ethernet1/40 sfp is present name is CISCO-MOLEX INC part number is 74752-9026 revision is A0 serial number is MOC13321057 nominal bitrate is 12000 MBits/sec Link length supported for 50/125mm fiber is 0 m(s) Link length supported for 62.5/125mm fiber is 0 m(s) cisco id is -- cisco extended id number is 4
This example shows how to display the status of the feature sets on the device:
switch# show feature-set Feature Set Name ID State -------------------- -------- -------- fcoe 1 installed fabricpath 2 enabled fex 3 enabled switch#
This example shows how to display the services used by the Fabric Extender feature set:
switch# show feature-set services fex vntag_mgr fex 2 services in feature set fex switch#
Use the following to display configuration information used on the switch supervisor to manage the Fabric Extender.
Command or Action |
Purpose |
---|---|
show environment fex {all | FEX-number} [temperature | power | fan] | Displays the environmental sensor status. |
show inventory fex FEX-number | Displays inventory information for a Fabric Extender. |
show module fex FEX-number | Displays module information about a Fabric Extender. |
show sprom fex FEX-number {all | backplane | powersupply ps-num} | all | Displays the contents of the serial PROM (SPROM) on the Fabric Extender. |
This example shows how to display the module information about all connected Fabric Extender units:
switch# show module fex FEX Mod Ports Card Type Model Status. --- --- ----- ---------------------------------- ------------------ ----------- 101 1 48 Fabric Extender 48x1GE + 4x10G M N2K-C2248TP-1GE ok FEX Mod Sw Hw World-Wide-Name(s) (WWN) --- --- -------------- ------ ----------------------------------------------- 101 1 5.1(1) 3.5 -- FEX Mod MAC-Address(es) Serial-Num --- --- -------------------------------------- ---------- 101 1 5475.d0a9.4940 to 5475.d0a9.496f JAF1418AARL
This example shows how to display the inventory information about a specific Fabric Extender:
switch# show inventory fex 101 NAME: "FEX 101 CHASSIS", DESCR: "N2K-C2248TP-1GE CHASSIS" PID: N2K-C2248TP-1GE , VID: V00 , SN: SSI13380FSM NAME: "FEX 101 Module 1", DESCR: "Fabric Extender Module: 48x1GE, 4x10GE Supervisor" PID: N2K-C2248TP-1GE , VID: V00 , SN: JAF1339BDSK NAME: "FEX 101 Fan 1", DESCR: "Fabric Extender Fan module" PID: N2K-C2248-FAN , VID: N/A , SN: N/A NAME: "FEX 101 Power Supply 2", DESCR: "Fabric Extender AC power supply" PID: NXK-PAC-400W , VID: 000, SN: LIT13370QD6
This example shows how to display the environment status for a specific Fabric Extender:
switch# show environment fex 101 Temperature Fex 101: ----------------------------------------------------------------- Module Sensor MajorThresh MinorThres CurTemp Status (Celsius) (Celsius) (Celsius) ----------------------------------------------------------------- 1 Outlet-1 60 50 33 ok 1 Outlet-2 60 50 38 ok 1 Inlet-1 50 40 35 ok 1 Die-1 100 90 44 ok Fan Fex: 101: ------------------------------------------------------ Fan Model Hw Status ------------------------------------------------------ Chassis N2K-C2148-FAN -- ok PS-1 -- -- absent PS-2 NXK-PAC-400W -- ok Power Supply Fex 101: --------------------------------------------------------------------------- Voltage: 12 Volts ----------------------------------------------------- PS Model Power Power Status (Watts) (Amp) ----------------------------------------------------- 1 -- -- -- -- 2 NXK-PAC-400W 4.32 0.36 ok Mod Model Power Power Power Power Status Requested Requested Allocated Allocated (Watts) (Amp) (Watts) (Amp) --- ------------------- ------- ---------- --------- ---------- ---------- 1 N2K-C2248TP-1GE 0.00 0.00 0.00 0.00 powered-up Power Usage Summary: -------------------- Power Supply redundancy mode: redundant Total Power Capacity 4.32 W Power reserved for Supervisor(s) 0.00 W Power currently used by Modules 0.00 W ------------- Total Power Available 4.32 W -------------
This example shows how to display the SPROM for a specific Fabric Extender:
switch# show sprom fex 101 all DISPLAY FEX 101 SUP sprom contents Common block: Block Signature : 0xabab Block Version : 3 Block Length : 160 Block Checksum : 0x1a1e EEPROM Size : 65535 Block Count : 3 FRU Major Type : 0x6002 FRU Minor Type : 0x0 OEM String : Cisco Systems, Inc. Product Number : N2K-C2248TP-1GE Serial Number : JAF1339BDSK Part Number : 73-12748-01 Part Revision : 11 Mfg Deviation : 0 H/W Version : 0.103 Mfg Bits : 0 Engineer Use : 0 snmpOID : 9.12.3.1.9.78.3.0 Power Consump : 1666 RMA Code : 0-0-0-0 CLEI Code : XXXXXXXXXTBDV00 VID : V00 Supervisor Module specific block: Block Signature : 0x6002 Block Version : 2 Block Length : 103 Block Checksum : 0x2686 Feature Bits : 0x0 HW Changes Bits : 0x0 Card Index : 11016 MAC Addresses : 00-00-00-00-00-00 Number of MACs : 0 Number of EPLD : 0 Port Type-Num : 1-48;2-4 Sensor #1 : 60,50 Sensor #2 : 60,50 Sensor #3 : -128,-128 Sensor #4 : -128,-128 Sensor #5 : 50,40 Sensor #6 : -128,-128 Sensor #7 : -128,-128 Sensor #8 : -128,-128 Max Connector Power: 4000 Cooling Requirement: 65 Ambient Temperature: 40 DISPLAY FEX 101 backplane sprom contents: Common block: Block Signature : 0xabab Block Version : 3 Block Length : 160 Block Checksum : 0x1947 EEPROM Size : 65535 Block Count : 5 FRU Major Type : 0x6001 FRU Minor Type : 0x0 OEM String : Cisco Systems, Inc. Product Number : N2K-C2248TP-1GE Serial Number : SSI13380FSM Part Number : 68-3601-01 Part Revision : 03 Mfg Deviation : 0 H/W Version : 1.0 Mfg Bits : 0 Engineer Use : 0 snmpOID : 9.12.3.1.3.914.0.0 Power Consump : 0 RMA Code : 0-0-0-0 CLEI Code : XXXXXXXXXTDBV00 VID : V00 Chassis specific block: Block Signature : 0x6001 Block Version : 3 Block Length : 39 Block Checksum : 0x2cf Feature Bits : 0x0 HW Changes Bits : 0x0 Stackmib OID : 0 MAC Addresses : 00-0d-ec-e3-28-00 Number of MACs : 64 OEM Enterprise : 0 OEM MIB Offset : 0 MAX Connector Power: 0 WWN software-module specific block: Block Signature : 0x6005 Block Version : 1 Block Length : 0 Block Checksum : 0x66 wwn usage bits: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 License software-module specific block: Block Signature : 0x6006 Block Version : 1 Block Length : 16 Block Checksum : 0x86f lic usage bits: ff ff ff ff ff ff ff ff DISPLAY FEX 101 power-supply 2 sprom contents: Common block: Block Signature : 0xabab Block Version : 3 Block Length : 160 Block Checksum : 0x1673 EEPROM Size : 65535 Block Count : 2 FRU Major Type : 0xab01 FRU Minor Type : 0x0 OEM String : Cisco Systems Inc NXK-PAC-400W Product Number : NXK-PAC-400W Serial Number : LIT13370QD6 Part Number : 341 Part Revision : -037 CLEI Code : 5-01 01 000 VID : 000 snmpOID : 12336.12336.12336.12336.12336.12336.12374.12336 H/W Version : 43777.2 Current : 36 RMA Code : 200-32-32-32 Power supply specific block: Block Signature : 0x0 Block Version : 0 Block Length : 0 Block Checksum : 0x0 Feature Bits : 0x0 Current 110v : 36 Current 220v : 36 Stackmib OID : 0
This section includes additional information that is related to configuring the Cisco Nexus 2000 Series Fabric Extender.
Related Topic |
Document Title |
---|---|
Cisco NX-OS Licensing |
Cisco NX-OS Licensing Guide |
Virtual device contexts (VDC) |
Cisco Nexus 7000 Series NX-OS Virtual Device Context Configuration Guide |
Interface configuration |
Cisco Nexus 7000 Series NX-OS Interfaces Configuration Guide |
Command reference |
Cisco Nexus 7000 Series Command References available at the following URL: http://www.cisco.com/en/US/products/ps9402/prod_command_reference_list.html |
Feature Name | Releases | Feature Information |
---|---|---|
Support for the Cisco Nexus 7000 Series |
6.1(1) |
Support was added when the FEX is connected to the 48-port, 100/1000 BASE-T (100-Mb/1-Gigabit) N2248TP-E, and 32-port 10-Gigabit SFP+ N2248TP-E. |
Support for M2 series modules |
6.1(1) |
Support for M2 series modules. |
Support for the Cisco Nexus 7000 Series |
6.0(1) |
Support was added when the FEX is connected to the 48-port, 1/10-Gigabit F2-Series module (N7K-F248XP-25). |
Support for the Cisco Nexus 7000 Series |
5.1(1) |
Support was added when the FEX is connected to the 32-port, 10-Gigabit M1 module (N7K-M132XP-12) or the 32-port, 10-Gigabit M1 XL module (N7K-M132XP-12L). |
Feature set commands |
5.1(1) |
The Fabric Extender is enabled on the parent Cisco Nexus 7000 Series device with the install feature-set and feature-set commands. |
Port channel and vPC support |
5.2(1) |
Support was added for port channels and the integration of vPC on the host interfaces. |
Layer 3 support |
5.2(1) |
Layer 3 capability was added to the Fabric Extender host interface ports including IPv4 and IPv6 and IGMP snooping. |