Technical Specifications

Switch Specifications

This section contains physical and environmental information about the switch.

Table 1. Physical Specifications

Switch

Weight

Dimensions (H x W x D)

IE9310 GE Fiber

12.2 lbs (5.53 kg)

Note

 

Weight is without power supply and blank filler.

  • 1.72 x 17.5 x 14.0 in. (4.36 x 44.45 x 35.56 cm) with PWR-RGDAC-DC-H / PWR-RGD-LOW-DC-H

  • 1.72 x 17.5 x 15.18 in. (4.36 x 44.45 x 38.55 cm) with PWR-RGDAC-DC-250

IE9320 GE Fiber

12.2 lbs (5.53 kg)

Note

 

Weight is without power supply and blank filler.

  • 1.72 x 17.5 x 14.0 in. (4.36 x 44.45 x 35.56 cm) with PWR-RGDAC-DC-H / PWR-RGD-LOW-DC-H

  • 1.72 x 17.5 x 15.18 in. (4.36 x 44.45 x 38.55 cm) with PWR-RGDAC-DC-250

IE9320 10GE Copper Data (IE-9320-24T4X)

9.5 lb (4.3 kg)

Note

 

Weight is without power supply and blank filler.

1.72 x 17.5 x 14.0 in. (4.36 x 44.45 x 35.56 cm) with PWR-RGD-AC-DC-H / PWR-RGD-LOW-DC-H

IE9320 10GE PoE

(IE-9320-24P4X)

9.7 lb (4.4 kg)

Note

 

Weight is without power supply and blank filler.

1.72 x 17.5 x 14.0 in. (4.36 x 44.45 x 35.56 cm) with PWR-RGD-AC-DC-H / PWR-RGD-LOW-DC-H

IE9320 10G mGig 4PPoE (IE-9320-16P8U4X)

9.9 lb (4.5 kg)

Note

 

Weight is without power supply and blank filler.

  • 1.72 x 17.5 x 14.0 in. (4.36 x 44.45 x 35.56 cm) with PWR-RGD-AC-DC-H / PWR-RGD-LOW-DC-H

  • 1.72 x 17.5 x 15.18 in. (4.36 x 44.45 x 38.55 cm) with PWR-RGD-AC-DC-250

  • 1.72 x 17.5 x 15.57 in. (4.36 x 44.45 x 39.55 cm) with PWR-RGD-AC-DC-400

IE9320 GE PoE (IE-9320-24P4S)

9.7 lb (4.4 kg)

Note

 

Weight is without power supply and blank filler.

  • 1.72 x 17.5 x 14.0 in. (4.36 x 44.45 x 35.56 cm) with PWR-RGD-AC-DC-H / PWR-RGD-LOW-DC-H

  • 1.72 x 17.5 x 15.18 in. (4.36 x 44.45 x 38.55 cm) with PWR-RGD-AC-DC-250

  • 1.72 x 17.5 x 15.57 in. (4.36 x 44.45 x 39.55 cm) with PWR-RGD-AC-DC-400

Table 2. Environmental Ranges
Measure Range

Operating temperature

  • –40° C to +75°C (blower equipped cabinet)

  • –40° C to +70° C (vented cabinet)

  • –40° C to +60° C (sealed cabinet)

Storage temperature

–40°C to +85°C

Relative humidity

5 percent to 95 percent noncondensing

Operating altitude

  • Up to 15,000 feet (4572 m) with no temperature derating

  • Up to 40,000 feet (12,192 m) with temperature derating down to 25° C

Storage altitude

Up to 40,000 feet (12,192 m)

Thermal spacing

1.75 in (4.4 cm) clearance top, sides, and bottom

Operational shock

50G at 11ms, half sine and 200G ar 2.11ms, half sine
Nonoperational shock 65 to 80G at 9ms, trapezoidal

Power-Supply Module Specifications

PSU Module

Weight

Dimensions

PWR-RGD-AC-DC-H

2.55 lb (1.15 kg)

1.58 x 7 x 5 in. (4 x 17.8 x 12.7 cm) (without mounting flanges)

PWR-RGD-LOW-DC-H

2.5 lb (1.13 kg)

PWR-RGD-LOW-DC-250

3.2 lb (1.45 kg)

1.58 x 7 x 6.18 in. (4 x 17.8 x 15.7 cm) (without mounting flanges)

PWR-RGD-AC-DC-400 3.55 lb (1.61 kg) 1.58 x 7 x 6.58 in. (4 x 17.8 x 16.7 cm) (without mounting flanges)

Blank cover

.8 lbs

N/A


Note


The safety certifications apply only to ambient temperatures under 140 F (60 C).


Table 3. Switch Power Requirements
Measure Requirement

Nominal input voltage

  • PWR-RGD-AC-DC-H:

    100 to 240 VAC, 50 to 60 Hz

    100 to 250 VDC

  • PWR-RGD-AC-DC-250:

    100 to 240 VAC, 50 to 60 Hz

    100 to 250 VDC

  • PWR-RGD-LOW-DC-H:

    24 to 60 VDC

  • PWR-RGD-AC-DC-400:

    100 to 240 VAC, 50 to 60Hz

    100 to 250 VDC

The 400W power supplies are required to support 4PPoE Type 4 (PoE Class 7 and 8). Any of the supported power supplies can be used for PoE+ and 4PPoE Type 3 (PoE Class 1 through 6).

Table 4. Cisco IE9300 Rugged Series PoE and PoE+ Power Budget

PID

Available PoE Power

One 150W PSU

Two 150W PSUs

One 250W PSU

One 150W PSU + one 250W PSU

Two 250W PSUs

400W

Two 400W PSUs

IE-9320-24P4S

70W

190W

170W

280W

370W

320W

385W

IE-9320-24P4X-E

70W

190W

170W

280W

370W

320W

720W

IE-9320-16P8U4X

70W

190W

170W

280W

370W

320W

720W


Note


150W and 250W power supplies cannot be used with the 400W power supply in a load-sharing configuration.


Alarm Ratings

Specification Description

Alarm input electrical specification

Senses an external dry contact. The open circuit voltage between any alarm input (1 to 4) and alarm input common is 3.3 VDC. The loop current is 3 mA max per input.

Do not apply external power to the alarm input.

Alarm output electrical specification

30VDC @ 1A, 60VDC @ 0.5A (resistive load only)


Caution


To reduce risk of electric shock and fire, the alarm ports must be connected to an IEC 60950/IEC 62368-compliant limited power source (LPS).

Attention :

Pour réduire les risques d’incendie et de décharge électrique, les ports d’alarme doivent être connectés à une source d’alimentation limitée (LPS) conforme aux normes IEC 60950/IEC 62368.