DLT-<MOD1PAYLOAD>:[<TID>]:<AID>:<CTAG>[::::]; Deletes the specified port (support limited to ports with pluggable port modules [PPMs]). |
DLT-NNI-ETH:[<TID>]:<AID>:<CTAG>::<SVLANID>[::]; Deletes the network-to-network interface (NNI) SVLAN ID for the NNI of an L2 Ethernet port. |
DLT-QNQ-ETH:[<TID>]:<AID>:<CTAG>::<FIRSTCEVLANID>,<LASTCEVLANID>, <SVLANID>[::]; Deletes the IEEE 802.1Q tunneling (QinQ) relationship between the CE-VLAN and the S-VLAN for Gigabit Ethernet uniport provisioning associated to an L2 Ethernet port. |
DLT-VLAN:[<TID>]:<AID>:<CTAG>[::::]; Deletes a virtual LAN from the VLAN database. |
ED-<GIGE_TYPE>:[<TID>]:<AID>:<CTAG>:::[ADMINSTATE=<ADMINSTATE>], [LINKSTATE=<LINKSTATE>],[MTU=<MTU>],[MFS=<MFS>],[FLOW=<FLOW>], [FLOWCTRL=<FLOWCTRL>],[AUTONEG=<AUTONEG>],[HIWMRK=<HIWMRK>], [LOWMRK=<LOWMRK>],[OPTICS=<OPTICS>],[DUPLEX=<DUPLEX>],[SPEED=<SPEED>], [NAME=<NAME>],[CMDMDE=<CMDMDE>],[MACADDR=<MACADDR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],[SUPPRESS=<SUPPRESS>],[SOAK=<SOAK>],SQUELCH=<SQUELCH>], [CIR=<CIR>],[CBS=<CBS>],[EBS=<EBS>],[LIENABLE=<LIENABLE>],[LITIMER=<LITIMER>]: [<PST>[,<SST>]]; Edits the Gigabit Ethernet Facility attributes. |
ED-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],[DISTEXTN= <DISTANCE_EXTENSION>],[AUTODETECTION=<AUTO_DETECTION>], [LINKCREDITS=<CREDITS>],[FASTSWITCH=<FASTSWITCH>],[MFS=<MAXFRMSIZE>] ,[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>], [LOSSB=<LOSSB>],[SQUELCH=<SQUELCH>][:<PST>[,<SST>]]; Edits the attributes related with the fibre channel facility (ONS 15454, ONS 15454 M2, and ONS 15454 M6). |
ED-<MOD1FICONPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],[DISTEXTN= <DISTANCE_EXTENSION>],[AUTODETECTION=<AUTO_DETECTION>], [LINKCREDITS=<CREDITS>],[FASTSWITCH=<FASTSWITCH>],[MFS=<MAXFRMSIZE>] ,[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>], [LOSSB=<LOSSB>],[SQUELCH=<SQUELCH>][:<PST>[,<SST>]]; Edits the attributes related with the fiber connection payload facility (ONS 15454, ONS 15454 M2, and ONS 15454 M6). |
ED-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[DCC=<DCC>],[AREA=<AREA>], [SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>], [SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[MUX=<MUX>], [SOAK=<SOAK>],[OSPF=<OSPF>],[LDCC=<LDCC>],[NAME=<NAME>], [CMDMDE=<CMDMDE>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>], [TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>],[SENDDUSFF=<SENDDUSFF>], [AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>],[LOSSB=<LOSSB>], [FOREIGNFEND=<FOREIGNFEND>],[FOREIGNIP=<FOREIGNIP>],OPRNOMINAL=<OPRNOMINAL>]:[<PST>[,<SST>]]; Edits the attributes and state of an OC-N facility. |
ED-ALS:[<TID>]:<AID>:<CTAG>[:::ALSMODE=<ALSMODE>],[ALSRCINT=<ALSRCINT>], [ALSRCPW=<ALSRCPW>],[OSRI=<OSRI>],[:]; Modifies the Automatic Laser Shutdown (ALS) attributes for all facilities that support the ALS feature (Not supported on ONS 15600). |
ED-COS-ETH:[<TID>]:<AID>:<CTAG>:::[QOSENABLED=<QOSENABLED>],[BW0=<BWO>], [WEIGHT0=<WEIGHT0>],[BW1=<BW1>],[WEIGHT1=<WEIGHT1>],[BW2=<BW2>], [WEIGHT2=<WEIGHT2>],[BW3=<BW3>],[WEIGHT3=<WEIGHT3>],[BW4=<BW4>], [WEIGHT4=<WEIGHT4>],[BW5=<BW5>],[WEIGHT5=<WEIGHT5>],[BW6=<BW6>], [WEIGHT6=<WEIGHT6>],[BW7=<BW7>],[WEIGHT7=<WEIGHT7>][:]; Edits the egress parameter of a cost-of-service table associated to an L2 Ethernet port. |
ED-DS1:[<TID>]:<AID>:<CTAG>:::[TACC=<TACC>],[TAPTYPE=<TAPTYPE>], [AISONLPBK=<AISONLPBK>],[MODE=<MODE>],[FMT=<FMT>], [BERTMODE=<BERTMODE>],[BERTPATTERN=<BERTPATTERN>], [BERTERRCOUNT=<BERTERRCOUNT>]; Edits the test access attributes for DS-1 access on a DS3XM-12 card (ONS 15454 only). |
ED-EC1:[<TID>]:<AID>:<CTAG>:::[PJMON=<PJMON>],[LBO=<LBO>],[SOAK=<SOAK>], [SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[EXPTRC=<EXPTRC>], [TRC=<TRC>],[TRCMODE=<TRCMODE>],[<TRCFORMAT>],[AISONLPBK=<AISONLPBK>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]]; Edits the attributes of an EC1 facility (ONS 15454, ONS 15454 M2, and ONS 15454 M6). |
ED-ETH:[<TID>]:<SRC>:<CTAG>:::[FLOW=<FLOW>],[EXPDUPLEX=<EXPDUPLEX>], [SELECTIVEAUTO=<SELECTIVEAUTO>],[EXPSPEED=<EXPSPEED>], [VLANCOS=<VLANCOS>],[IPTOS=<IPTOS>],[NAME=<NAME>],[CMDMDE=<CMDMDE>], [SUPPRESS=<SUPPRESS>],[SOAK=<SOAK>],[LITIMER=<LITIMER>]:[<PST>[,<SST>]]; Edits the front-end port information of a 10/100/1000 Mbps Ethernet card. |
ED-FAC:[<TID>]:<SRC>:<CTAG>:::[PAYLOAD=<PAYLOAD>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]]; Provisions the payload (or signal) type of facility. |
ED-EFM:[<TID>]:<AID>:<CTAG>:::[EFMSTATE=<EFMSTATE>],[EFMMODE=<EFMMODE>], [MAXPDUS=<MAXPDUS>],[MAXIDLINTRVL=<MAXIDLINTRVL>], [RMTTMOUT=<RMTTMOUT>],[LNKMNTR=<LNKMNTR>],[OPRLNKMNTR= <OPRLNKMNTR>],[EF=<EF>],[EFTH=<EFTHRSLD>],[EFP=<EFP>],[EFPTH=<EFPTH>], [EFS=<EFS>],[EFSTH=<EFSTH>]; Edits the ethernet OAM parameters on the front end port of the fast (10/100 Mbps) ethernet card. |
ED-FSTE:[<TID>]:<SRC>:<CTAG>[:::FLOW=<FLOW>],[EXPDUPLEX=<EXPDUPLEX>], [EXPSPEED=<EXPSPEED>],[SELECTIVEAUTO=<SELECTIVEAUTO>], [VLANCOS=<VLANCOSTHRESHOLD>],[IPTOS=<IPTOSTHRESHOLD>],[NAME=<NAME>], [CMDMDE=<CMDMDE>],[SUPPRESS=<SUPPRESS>],[SOAK=<SOAK>], [LIENABLE=<LIENABLE>],[LITIMER=<LITIMER>],[FREQ=<FREQ>],[LOSSB=<LOSSB>], [CIR=<CIR>],[CBS=<CBS>],[EBS=<EBS>],[OSC=<OSC>][:<PST>[,<SST>]]; Edits the front-end port information of fast Ethernet (10/100 Mbps) cards (ONS 15454, ONS 15454 M2, and ONS 15454 M6). |
ED-G1000:[<TID>]:<AID>:<CTAG>:::[MFS=<MFS>],[FLOW=<FLOW>], [LOWMRK=<LOWMRK>],[HIWMRK=<HIWMRK>],[AUTONEG=<AUTONEG>], [NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]]; Edits the attributes related to a G1000-4 port (ONS 15454, ONS 15454 M2, and ONS 15454 M6). |
ED-GFP:[<TID>]:<AID>:<CTAG>:::[FCS=<FCS>],[AUTOTHGFPBUF=<AUTOTHGFPBUF>], [GFPBUF=<GFPBUF>],[FILTER=<FILTER>]; Edits the Generic Framing Procedure (GFP) port on the ONS 15454 CE-100T-8, FC_MR-4, and CE-1000-4 card; and the ONS 15600 ASAP-4 card. |
ED-L2-ETH:[<TID>]:<AID>:<CTAG>[:::NIMODE=<NIMODE>], [MACLEARNING=<MACLEARNING>],[INGRESSCOS=<INGRESSCOS>], [ETHERCETYPE=<ETHER_CE_TYPE>],[ETHERSTYPE=<ETHER_S_TYPE>], [ALWMACADDR=<ALW_MAC_ADDR>],[INHMACADDR=<INH_MAC_ADDR>], [BPDU=<BPDU>],[BRIDGESTATE=<BRIDGE_STATE>],[QNQMODE=<QNQMODE>], [TRNSPSVLAN=<TRNSP_SVLAN>],[NAME=<NAME>],[IGMPROUTER=<IGMPROUTER>], [AISACTION=<AISACTION>],[PROTACTION=<PROTACTION>],[CMDMDE=<CMDMD>], [IGMPCVLAN=<IGMPCVLAN>],[DLF=<DLF>],[DLFTHRES=<DLFTHRES>], [MCAST=<MCAST>],[MCASTTHRES=<MCASTTHRES>],[BCAST=<BCAST>], [BCASTTHRES=<BCASTTHRES>],[CLRCRCALM=<CLRCRCALM>][:]; Edits the Layer 2 port information of GE-XP, GE_XPE, 10GE-XP, and 10GE_XPE Ethernet cards. |
ED-POS:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>],[NAME=<NAME>], [CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]]; Edits the back-end virtual port information on the ONS 15454 CE-100T-8 and CE-1000-4 cards; and the ONS 15600 ASAP-4 card. |
ED-QNQ-ETH:[<TID>]:<AID>:<CTAG>::<FIRSTCEVLANID>,<LASTCEVLANID>, <SVLANID>:[RULE=<RULE>][:]; Modifies the IEEE 802.1Q tunneling (QinQ) relationship between the customer CE-VLAN and the S-VLAN for Gigabit Ethernet uniport provisioning associated to an L2 Ethernet port. |
ED-T1:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>], [TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],[SFBER=<SFBER>], [SDBER=<SDBER>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>], [NAME=<NAME>],[CMDMDE=<CMDMDE>],[AISONLPBK=<AISONLPBK>], [MODE=<MODE>],[SYNCMAP=<SYNCMAP>],[ADMSSM=<ADMSSM>], [VTMAP=<VTMAP>],[AISVONAIS=<AISVONAIS>],[AISONLOF=<AISONLOF>], [INHFELPBK=<INHFELPBK>],[INHFEBPLPBK=<INHFEBPLPBK>], [BERTMODE=<BERTMODE>],[BERTPATTERN=<BERTPATTERN>], [BERTERRCOUNT=<BERTERRCOUNT>]:[<PST>[,<SST>]]; Edits the attributes related a DS1/T1 port (not supported on the ONS 15600). |
ED-T3:[<TID>]:<AID>:<CTAG>:::[FMT=<FMT>],[LINECDE=<LINECDE>],[LBO=<LBO>], [INHFELPBK=<INHFELPBK>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>], [SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[AISONLPBK=<AISONLPBK>], [CMDMDE=<CMDMDE>],[BERTMODE=<BERTMODE>], [BERTPATTERN=<BERTPATTERN>],[BERTERRCOUNT=<BERTERRCOUNT>]: [<PST>[,<SST>]]; Edits the attributes related to a DS3/T3 port (not supported on the ONS 15600). |
ED-VLAN:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],[PROTN=<PROTN>][:]; Modifies a VLAN entry in the VLAN database. |
ENT-<MOD1PAYLOAD>:[<TID>]:<AID>:<CTAG>[::::]; Provisions the specified port (support limited to ports with pluggable port modules [PPMs]). |
ENT-NNI-ETH:[<TID>]:<AID>:<CTAG>::<SVLANID>[::]; Adds a new network-to-network interface service provider VLAN ID to the NNI interface of an L2 Ethernet port. |
ENT-QNQ-ETH:[<TID>]:<AID>:<CTAG>::<FIRSTCEVLANID>,<LASTCEVLANID>, <SVLANID>:[RULE=<RULE>][:]; Enters a new IEEE 802.1Q tunneling (QinQ) relationship between the CE-VLAN and S-VLAN for Gigabit Ethernet uniport provisioning associated to an L2 Ethernet port. |
ENT-VLAN:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],[PROTN=<PROTN>]; Adds a new VLAN entry to the VLAN database. |
OPR-ALS:[<TID>]:<AID>:<CTAG>[::::]; Restarts the laser of an OC-N facility and all the facilities that support the ALS feature. (ONS 15454, ONS 15454 M2, and ONS 15454 M6). |
RMV-<MOD2>:[<TID>]:<AID>:<CTAG>[::]; Removes a facility from service. |
RST-<MOD2>:[<TID>]:<AID>:<CTAG>::::[<PST>],[<SST>]; Provisions a facility in service. |
RTRV-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the attributes related with the fibre channel (FC) port (ONS 15454, ONS 15454 M2, and ONS 15454 M6). Output format: SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:LINKRATE=<LINKRATE>,LINKSTATE=<LINKSTATE>, [LINKRCVRY=<LINKRCVRY>],[DISTEXTN=<DISTEXTN>], [LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[ENCAP=<ENCAP>],[NAME=<NAME>], [SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]: <PST_PSTQ>,[<SST>]" ; |
RTRV-<MOD1FICONPAYLOAD>:[<TID>]:<AID>:<CTAG>; Retrieves the fibre-channel-specific settings for ports which have been configured to carry FICON traffic (ONS 15454, ONS 15454 M2, and ONS 15454 M6). Output format: SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[LINKRATE=<LINKRATE>],[LINKSTATE=<LINKSTATE>], [LINKRCVRY=<LINKRCVRY>],[DISTEXTN=<DISTEXTN>], [LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[ENCAP=<ENCAP>],[NAME=<NAME>], [SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]: <PST_PSTQ>,<SST>" ; |
RTRV-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the attributes and state of an OC-N facility. Output format: SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[DCC=<DCC>],[AREA=<AREA>],[TMGREF=<TMGREF>], [SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>], [SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[WVLEN=<WVLEN>], [RINGID=<RINGID>],[BLSRTYPE=<BLSRTYPE>],[MUX=<MUX>],[UNIC=<UNIC>], [CCID=<CCID>],[NBRIX=<NBRIX>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>], [SSMRCV=<SSMRCV>],[OSPF=<OSPF>],[LDCC=<LDCC>],[NAME=<NAME>], [LBCL=<LBCL>],[OPT=<OPT>],[OPR=<OPR>],[EXPTRC=<EXPTRC>],[TRC=<TRC>], [TRCMODE=<TRCMODE>],[TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>], [SENDDUSFF=<SENDDUSFF>],[AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>], [LOSSB=<LOSSB>],[FOREIGNFEND=<FOREIGNFEND>], [FOREIGNIPADDRESS=<FOREIGNIPADDRESS>],:<PSTPSTQ>,[<SSTQ>]" ; |
RTRV-10GIGE:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the 10 Gigabit per second specific parameters for the port (ONS 15454, ONS 15454 M2, and ONS 15454 M6). Output format: SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[NAME=<NAME>],[MACADDR=<MACADDR>], [LBCL=<LBCL>],[OPT=<OPT>],[OPR=<OPR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]: <PSTPSTQ>,[<SST>]" ; |
RTRV-ALS:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the ALS attributes of an OC-N facility and all facilities that support the ALS feature. Output format: SID DATE TIME M CTAG COMPLD "<AID>,[<AIDTYPE>]:[<ALSMODE>],[<ALSRCINT>],[<ALSRCPW>],[<LSRSTAT>],[<OSRI>]" ; |
RTRV-COS-ETH:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the egress parameters of a CoS table associated to an L2 Ethernet port. Output format: SID DATE TIME M CTAG COMPLD "<AID>::[QOSENABLED=<QOSENABLED>],[BW0=<BWO>], [WEIGHT0=<WEIGHT0>],[BW1=<BW1>],[WEIGHT1=<WEIGHT1>],[BW2=<BW2>], [WEIGHT2=<WEIGHT2>],[BW3=<BW3>],[WEIGHT3=<WEIGHT3>],[BW4=<BW4>], [WEIGHT4=<WEIGHT4>],[BW5=<BW5>],[WEIGHT5=<WEIGHT5>],[BW6=<BW6>], [WEIGHT6=<WEIGHT6>],[BW7=<BW7>],[WEIGHT7=<WEIGHT7>][:]" ; |
RTRV-DS1:[<TID>]:<DS1AID>:<CTAG>[::::]; Retrieves the test access attributes on a DS-1 layer of DS3XM card (ONS 15454, ONS 15454 M2, and ONS 15454 M6). Output format: SID DATE TIME M CTAG COMPLD "<DS1AID>::[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[AISONLPBK=<AISONLPBK>], [MODE=<MODE>],[FMT=<FMT>],[BERTMODE=<BERTMODE>], [BERTPATTERN=<BERTPATTERN>],[BERTERRCOUNT=<BERTERRCOUNT>], [BERTERRRATE=<BERTERRRATE>], [BERTSYNCSTATUS=<BERTSYNCSTATUS>]" ; |
RTRV-EC1:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the facility status of an EC-1 port (ONS 15454, ONS 15454 M2, and ONS 15454 M6). Output format: SID DATE TIME M CTAG COMPLD "<AID>::[PJMON=<PJMON>],[LBO=<LBO>],[RXEQUAL=<RXEQUAL>],[SOAK=<SOAK>], [SOAKLEFT=<SOAKLEFT>],[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>], [EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>], [TRCFORMAT=<TRCFORMAT>],[AISONLPBK=<AISONLPBK>]:<PSTPSTQ>,[<SSTQ>]" ; |
RTRV-ESCON:[<TID>]:<AID>:<CTAG>; Retrieves fibre-channel-specific settings for ports that have been configured to carry ESCON traffic (ONS 15454, ONS 15454 M2, and ONS 15454 M6). Output format: SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[ENCAP=<ENCAP>]" ; |
RTRV-FAC:[<TID>]:<SRC>:<CTAG>[::::]; Retrieves the payload type of the facility. Only applicable to a facility with a provisionable type. Output format: SID DATE TIME M CTAG COMPLD "<SRC>::PAYLOAD=<PAYLOAD>:<PST_PSTQ>,[<SSTQ>]" ; |
RTRV-FSTE:[<TID>]:<AID>:<CTAG>; Retrieves the front end port information of Fast Ethernet (10/100 Mbps) cards (ONS 15454, ONS 15454 M2, and ONS 15454 M6). Output format: SID DATE TIME M CTAG COMPLD "<AID>:[<ROLE>],[<STATUS>]:[<ADMINSTATE>],[<LINKSTATE>],[<MTU>], [<FLOWCTRL>],[<OPTICS>],[<DUPLEX>],[<SPEED>],[<FLOW>],[<EXPDUPLEX>], [<EXPSPEED>],[<VLANCOSTHRESHOLD>],[<IPTOSTHRESHOLD>],[<NAME>], [<SUPPRESS>],[<SOAK>],[<SOAKLEFT>],[<SELECTIVEAUTO>],[<LIENABLE>], [<LITIMER>],[<LBCL>],[<OPT>],[<OPR>],[<FREQ>],[<LOSSB>],[<ACTFLOW>], [<ACTDUPLEX>],[<ACTSPEED>],[<CIR>],[<CBS>],[<EBS>],[<OSC>]:<PST>,[<SST>]" ; |
RTRV-G1000:[<TID>]:<AID>:<CTAG>; Retrieves the G1000-4 facility configuration (ONS 15454, ONS 15454 M2, and ONS 15454 M6). Output format: SID DATE TIME M CTAG COMPLD "<AID>::[MFS=<MFS>],[FLOW=<FLOW>],[LAN=<LAN>],[OPTICS=<OPTICS>], [TRANS=<TRANS>],[TPORT=<TPORT>],[LOWMRK=<LOWMRK>], [HIWMRK=<HIWMRK>],[AUTONEG=<AUTONEG>],[ENCAP=<ENCAP>], [NAME=<NAME>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>]:<PST_PSTQ>,[<SSTQ>]" ; |
RTRV-GFP:[<TID>]:<SRC>:<CTAG>; Retrieves the GFP port information on the ONS 15454 CE-100T-8, FC_MR-4, CE-MR-10, and CE-1000-4 cards; and the ONS 15600 ASAP-4 card. Output format: SID DATE TIME M CTAG COMPLD "<AID>::[FCS=<FCS>],[AUTOTHGFPBUF=<AUTOTHGFPBUF>],[GFPBUF=<GFPBUF>], [FILTER=<FILTER>]" ; |
RTRV-GIGE:[<TID>]:<AID>:<CTAG>; Retrieves the front-end port information for the ONS 15454 ML1000-2 and CE-1000-4 cards; and the ONS 15600 ASAP-4 card. Output format: SID DATE TIME M CTAG COMPLD "<AID>:[<ROLE>],[<STATUS>]:[<ADMINSTATE>],[<LINKSTATE>],[<MTU>],[<MFS>], [<FLOW>],[<FLOWCTRL>],[<AUTONEG>],[<HIWMRK>],[<LOWMRK>],[<OPTICS>], [<DUPLEX>],[<SPEED>],[<NAME>],[<MACADDR>],[<LBCL>],[<OPT>],[<OPR>],[<FREQ>], [<LOSSB>],[<SUPPRESS>],[<SOAK>],[<SOAKLEFT>],[<SQUELCH>],[<CIR>],[<CBS>],[<EBS>], [<LIENABLE>],[<LITIMER>],[<ACTFLOW>],[<ACTDUPLEX>],[<ACTSPEED>],[<OSC>], [<ENCAP>],[<PAUSEFRAME>],[<CLNTDST>]:<PST>,[<SST>]" ; |
RTRV-L2-ETH:[<TID>]:<AID>:<CTAG>[:::]; Retrieves the Layer 2 port information of the Ethernet card. Output format: SID DATE TIME M CTAG COMPLD "<AID>::[<NIMODE>],[<MACLEARNING>],[<INGRESSCOS>],[<ETHERCETYPE>], [<ETHERSTYPE>],[<ALWMACADDR>],[<INHMACADDR>],[<BPDU>],[<BRIDGESTATE>], [<ACTBRIDGESTATE>],[<QNQMODE>],[<TRNSPSVLAN>],[<NAME>],[<IGMPROUTER>], [<AISACTION>],[<PROTACTION>],[<IGMPCVLAN>],[<DLF>],[<DLFTHRES>],[<MCAST>], [<MCASTTHRES>],[<BCAST>],[<BCASTTHRES>]:" ; |
RTRV-NNI-ETH:[<TID>]:<AID>:<CTAG>::[<SVLANID>][::]; Retrieves the NNI selective S-VLAN-ID table associated to an L2 Ethernet port. Output format: SID DATE TIME M CTAG COMPLD "<AID>:<S_VLAN_ID>[::]" ; |
RTRV-POS:[<TID>]:<AID>:<CTAG>; Retrieves the back-end port information for the ML-Series Ethernet cards when the back-end port is working in POS mode (not supported on the ONS 15600). Output format: SID DATE TIME M CTAG COMPLD "<AID>::[ADMINSTATE=<ADMINSTATE>],[LINKSTATE=<LINKSTATE>],[MTU=<MTU>], [ENCAP=<ENCAP>],[NAME=<NAME>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>]: <PST_PSTQ>,[<SST>]" ; |
RTRV-QNQ-ETH:[<TID>]:<AID>:<CTAG>::<FIRSTCEVLAN_ID>,<LASTCEVLANID>, <SVLANID>[:]; Retrieves the IEEE 802.1Q tunneling (QinQ) relationship between the CE-VLAN and the S-VLAN for Gigabit Ethernet uniport provisioning associated to an L2 Ethernet port. Output format: SID DATE TIME M CTAG COMPLD "<AID>:<FIRSTCEVLANID>,<LASTCEVLANID>,<SVLANID>:RULE=<RULE>[:]" ; |
RTRV-T1:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the DS-1 facilities configuration (not supported on the ONS 15600). Output format: SID DATE TIME M CTAG COMPLD "<AID>::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>],[TACC=<TAP>], [TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[SFBER=<SFBER>], [SDBER=<SDBER>],[NAME=<NAME>],[SYNCMSG=<SYNCMSG>], [SENDDUS=<SENDDUS>],[RETIME=<RETIME>],[AISONLPBK=<AISONLPBK>], [AISVONAIS=<AISVONAIS>],[AISONLOF=<AISONLOF>],[MODE=<MODE>], [SYNCMAP=<SYNCMAP>],[ADMSSM=<ADMSSM>],[PROVIDESYNC=<PROVIDESYNC>], [VTMAP=<VTMAP>],[INHFELPBK=<INHFELPBK>],[BERTMODE=<BERTMODE>], [BERTPATTERN=<BERTPATTERN>],[BERTERRCOUNT=<BERTERRCOUNT>], [BERTERRRATE=<BERTERRRATE>],[BERTSYNCSTATUS=<BERTSYNCSTATUS>]: <PST>,[<SST>]" ; |
RTRV-T3:[<TID>]:<AID>:<CTAG>[::::]; Retrieves the facilities properties of a DS3, DS3I, or DS3 transmux card (not supported on the ONS 15600). Output format: SID DATE TIME M CTAG COMPLD "<AID>::[FMT=<FMT>],[LINECDE=<LINECDE>],[LBO=<LBO>], [INHFELPBK=<INHFELPBK>],[TACC=<TAP>],[TAPTYPE=<TAPTYPE>], [SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[SFBER=<SFBER>],[SDBER=<SDBER>], [NAME=<NAME>],[AISONLPBK=<AISONLPBK>][BERTMODE=<BERTMODE>], [BERTPATTERN=<BERTPATTERN>],[BERTERRCOUNT=<BERTERRCOUNT>], [BERTERRRATE=<BERTERRRATE>],[BERTSYNCSTATUS=<BERTSYNCSTATUS>]: <PST>,[<SST>]" ; |
|
RTRV-VLAN:[<TID>]:<AID>:<CTAG>[::::]; Retrieves a virtual LAN entry from the VLAN database. Output format: SID DATE TIME M CTAG COMPLD "<AID>::[NAME=<NAME>],[PROTN=<PROTN>]:" ; |
TST-INSERRBITS-<MOD2>:[<TID>]:<AID>:<CTAG>:::BITERRS=<BITERRS>; Tests the connectivity and error count on the traffic line, running on a port of an electrical card. |