Cisco ASA 5512-X, ASA 5515-X, ASA 5525-X, ASA 5545-X, and ASA 5555-X Quick Start Guide
3. Modify the Initial Configuration for the ASA FirePOWER Module (Optional)
6. Run Other ASDM Wizards and Advanced Configuration
7.Configure the ASA FirePOWER Module
Last Updated: October 28, 2020
The Cisco ASA 5500-X series is a powerful desktop firewall with the integrated FirePOWER software module. The ASA FirePOWER module supplies next-generation firewall services, including Next-Generation Intrusion Prevention System (NGIPS), Application Visibility and Control (AVC), URL filtering, and Advanced Malware Protection (AMP).
Note: ASA 9.14(x) was the final version for the ASA 5525-X, 5545-X, and 5555-X.
Note: ASA 9.12(x) was the final version for the ASA 5512-X and 5515-X.
Note: The ASA 5512-X does not support the FirePOWER module in Version 9.10 and later.
The ASA 5512-X includes the Base or Security Plus license, depending on the version you ordered. The ASA 5515-X through 5555-X includes the Base license. You can optionally purchase the following licenses:
They also come pre-installed with the Strong Encryption (3DES/AES) license if you qualify for its use. If you need to manually request the Strong Encryption license (which is free), see http://www.cisco.com/go/license.
If you want to upgrade from the Base license to the Security Plus license (ASA 5512-X), or purchase other licenses, see http://www.cisco.com/go/ccw. See also the Cisco AnyConnect Ordering Guide and the AnyConnect Licensing Frequently Asked Questions (FAQ). You will then receive an email with a Product Authorization Key (PAK) so you can obtain the license activation key. For the AnyConnect licenses, you receive a multi-use PAK that you can apply to multiple ASAs that use the same pool of user sessions.
Note: The serial number used for licensing is different from the chassis serial number printed on the outside of your hardware. The chassis serial number is used for technical support, but not for licensing. To view the licensing serial number, enter the show version | grep Serial command or see the ASDM Configuration > Device Management > Licensing Activation Key page.
The ASA FirePOWER module uses a separate licensing mechanism from the ASA. No licenses are pre-installed, but the box includes a PAK on a printout that lets you obtain a license activation key for the following licenses:
The Control (AVC) updates are included with a Cisco support contract.
The Protection (IPS) updates require you to purchase the IPS subscription from http://www.cisco.com/go/ccw. This subscription includes entitlement to Rule, Engine, Vulnerability, and Geolocation updates. Note: This right-to-use subscription does not generate or require a PAK/license activation key for the ASA FirePOWER module; it just provides the right to use the updates.
Other licenses that you can purchase include the following:
These licenses do generate a PAK/license activation key for the ASA FirePOWER module. See the Cisco Firepower System Feature Licenses for more information.
To install the Control and Protection licenses and other optional licenses, see Install the Licenses.
1. Attach the power cable to the ASA and connect it to an electrical outlet.
The power turns on automatically when you plug in the power cable; do not press the power button on the front panel. (For older models, the power does not turn on automatically; check the hardware installation guide for more information).
2. Check the Power LED on the front of the ASA; if it is solid green, the device is powered on.
3. Check the Status LED on the front of the ASA; after it is solid green, the system has passed power-on diagnostics.
The ASA ships with a default configuration that enables Adaptive Security Device Manager (ASDM) connectivity to the Management 0/0 interface. When you use a software module such as the ASA FirePOWER module, we recommend that you do not use the default configuration, which can preclude the ASA FirePOWER module from reaching the Internet for updates. This section describes how to apply a new configuration so the ASA FirePOWER can access the Internet. This configuration also enables a basic usable configuration for an inside and outside network.
The following figure shows the recommended network deployment for the ASA 5500-X with the ASA FirePOWER module. This deployment includes an inside bridge group that includes all but the outside interface so you can use these interfaces as an alternative to an external switch.
Note: The ASA 5525-X, 5545-X, and 5555-X include interfaces GigabitEthernet 0/0 through GigabitEthernet 0/7.
This procedure lets you connect to the ASA console port and paste in a new configuration that configures the following behavior:
Note: Do not configure an IP address for this interface in the ASA configuration. Only configure an IP address in the FirePOWER configuration. You should consider this interface as completely separate from the ASA in terms of routing.
Note: If you want to deploy a separate router on the inside network, then you can route between management and inside. In this case, you can manage both the ASA and ASA FirePOWER module on Management 0/0 with the appropriate configuration changes.
1. Connect your computer to the ASA console port with the supplied console cable. You might need to use a third party serial-to-USB cable to make the connection.
2. Launch a terminal emulator and connect to the ASA.
3. Press the Enter key to see the following prompt:
4. Access privileged EXEC mode:
5. Press Enter. By default, the password is blank.
6. Access global configuration mode:
8. Copy and paste the following configuration at the prompt. Omit commands with GigabitEthernet0/6 and GigabitEthernet0/7 and inside_6 and inside_7 for the ASA 5512-X and 5515-X.
9. Save the new configuration:
a. Cable Management 0/0 (for the ASA FirePOWER module) directly to one of: GigabitEthernet 0/1 through GigabitEthernet 0/5 (through 0/7 for the ASA 5525-X, 5545-X, and 5555-X).
Note: You can connect inside and management on the same network because the management interface acts like a separate device that belongs only to the ASA FirePOWER module.
b. Cable your computer to one of: GigabitEthernet 0/1 through GigabitEthernet 0/5 (through 0/7 for the ASA 5525-X, 5545-X, and 5555-X).
c. Cable GigabitEthernet 0/0 (outside) to your WAN device, for example, your cable modem.
Note: If the cable modem supplies an outside IP address that is on 192.168.1.0/24 or 192.168.10.0/24, then you must change the ASA configuration to use a different IP address. Interface IP addresses, HTTPS (ASDM) access, and DHCP server settings can all be changed using the Startup Wizard. If you change the IP address to which you are connected to ASDM, you will be disconnected when you finish the wizard. You must reconnect to the new IP address.
The following figure shows the suggested network deployment for the ASA 5500-X with the ASA FirePOWER module:
Note: If you have an inside router instead of a switch, you can skip this section and instead configure the ASA to route between management and an inside network. In this case, configure the ASA and the ASA FirePOWER Management 0/0 IP addresses to be on the same network. Be sure to configure appropriate routes on the ASA and on the ASA FirePOWER so the management network can reach the inside network, and vice versa.
This procedure lets you connect to the ASA console port and paste in a new configuration that configures the following behavior:
Note: Do not configure an IP address for this interface in the ASA configuration. Only configure an IP address in the module configuration. You should consider this interface as completely separate from the ASA in terms of routing.
To achieve the above configuration, perform the following steps.
1. Connect your computer to the ASA console port with the supplied console cable. You might need to use a third party serial-to-USB cable to make the connection.
2. Launch a terminal emulator and connect to the ASA.
3. Press the Enter key to see the following prompt:
4. Access privileged EXEC mode:
5. Press Enter. By default, the password is blank.
6. Access global configuration mode:
8. Copy and paste the following configuration at the prompt:
9. Save the new configuration:
a. Cable the following to a Layer 2 Ethernet switch:
–GigabitEthernet 0/1 interface (inside)
–Management 0/0 interface (for the module)
Note: You can connect inside and management on the same network because the management interface acts like a separate device that belongs only to the ASA FirePOWER module.
b. Connect the outside GigabitEthernet 0/0 interface to your upstream router or WAN device.
Note: If the cable modem supplies an outside IP address that is on 192.168.1.0/24 or 192.168.10.0/24, then you must change the ASA configuration to use a different IP address. Interface IP addresses, HTTPS (ASDM) access, and DHCP server settings can all be changed using the Startup Wizard. If you change the IP address to which you are connected to ASDM, you will be disconnected when you finish the wizard. You must reconnect to the new IP address.
See the ASDM release notes on Cisco.com for the requirements to run ASDM.
This procedure assumes you want to use ASDM to manage the ASA FirePOWER Module. If you want to use the Firepower Management Center, then you need to connect to the module CLI and run the setup script; see the ASA FirePOWER quick start guide.
1. On the computer connected to the ASA, launch a web browser.
2. In the Address field, enter the following URL: https://192.168.1.1/admin. The Cisco ASDM web page appears.
3. Click one of the available options: Install ASDM Launcher, Run ASDM, or Run Startup Wizard.
4. Follow the onscreen instructions to launch ASDM according to the option you chose. The Cisco ASDM-IDM Launcher appears.
If you click Install ASDM Launcher, in some cases you need to install an identity certificate for the ASA and a separate certificate for the ASA FirePOWER module according to Install an Identity Certificate for ASDM.
5. Leave the username and password fields empty, and click OK. The main ASDM window appears.
6. If you are prompted to provide the IP address of the installed ASA FirePOWER module, cancel out of the dialog box. You must first set the module IP address to the correct IP address using the Startup Wizard.
ASDM can change the ASA FirePOWER module IP address settings over the ASA backplane; but for ASDM to then manage the module, ASDM must be able to reach the module (and its new IP address) on the Management 0/0 interface over the network. The recommended deployment allows this access because the module IP address is on the inside network. If ASDM cannot reach the module on the network after you set the IP address, then you will see an error.
7. Choose Wizards > Startup Wizard.
8. Configure additional ASA settings as desired, or skip screens until you reach the ASA FirePOWER Basic Configuration screen.
Set the following values to work with the default configuration:
9. Click I accept the agreement, and click Next or Finish to complete the wizard.
10. Quit ASDM, and then relaunch. You should see ASA FirePOWER tabs on the Home page.
ASDM includes many wizards to configure your security policy. See the Wizards menu for all available wizards.
To continue configuring your ASA, see the documents available for your software version at Navigating the Cisco ASA Series Documentation.
Use ASDM to install licenses, configure the module security policy, and send traffic to the module.
Note: You can alternatively use the Firepower Management Center to manage the ASA FirePOWER module. See the ASA FirePOWER Module Quick Start Guide for more information.
The Control and Protection licenses are provided by default and the Product Authorization Key (PAK) is included on a printout in your box. If you ordered additional licenses, you should have PAKs for those licenses in your email.
1. Obtain the License Key for your chassis by choosing Configuration > ASA FirePOWER Configuration > Licenses and clicking Add New License.
The License Key is near the top; for example, 72:78:DA:6E:D9:93:35.
2. Click Get License to launch the licensing portal. Alternatively, in your browser go to http://www.cisco.com/go/license.
3. Enter the PAKs separated by commas in the Get New Licenses field, and click Fulfill.
4. You will be asked for the License Key and email address among other fields.
5. Copy the resulting license activation key from either the website display or from the zip file attached to the licensing email that the system automatically delivers.
6. Return to the ASDM Configuration > ASA FirePOWER Configuration > Licenses > Add New License screen.
7. Paste the license activation key into the License box.
8. Click Verify License to ensure that you copied the text correctly, and then click Submit License after verification.
1. Choose Configuration > ASA FirePOWER Configuration to configure the ASA FirePOWER security policy.
Use the ASA FirePOWER pages in ASDM for information. You can click Help in any page, or choose Help > ASA FirePOWER Help Topics, to learn more about how to configure policies.
See also the ASA FirePOWER module user guide.
1. To send traffic to the module, choose Configuration > Firewall > Service Policy Rules.
2. Choose Add > Add Service Policy Rule.
3. Choose whether to apply the policy to a particular interface or apply it globally and click Next.
4. Configure the traffic match. For example, you could match Any Traffic so that all traffic that passes your inbound access rules is redirected to the module. Or, you could define stricter criteria based on ports, ACL (source and destination criteria), or an existing traffic class. The other options are less useful for this policy. After you complete the traffic class definition, click Next.
5. On the Rule Actions page, click the ASA FirePOWER Inspection tab.
6. Check the Enable ASA FirePOWER for this traffic flow check box.
7. In the If ASA FirePOWER Card Fails area, click one of the following:
– Permit traffic —Sets the ASA to allow all traffic through, uninspected, if the module is unavailable.
– Close traffic —Sets the ASA to block all traffic if the module is unavailable.
8. (Optional) Check Monitor-only to send a read-only copy of traffic to the module, i.e. passive mode.
9. Click Finish and then Apply.