- attach (virtual switch)
- clear mls acl counters (virtual switch)
- clear mls netflow (virtual switch)
- clear mls statistics (virtual switch)
- dual-active detection (virtual switch)
- dual-active exclude (virtual switch)
- dual-active fast-hello (virtual switch)
- fabric buffer-reserve (virtual switch)
- fabric clear-block (virtual switch)
- fabric error-recovery fabric-switchover (virtual switch)
- fabric required (virtual switch)
- fabric switching-mode allow (virtual switch)
- fabric switching-mode force bus-mode (virtual switch)
- hw-module (virtual switch)
- interface (virtual switch)
- mac-address (virtual switch)
- mac-address-table learning (virtual switch)
- mls ip multicast egress fast-redirect
- module provision (virtual switch)
- monitor session servicemodule (virtual switch)
- platform hardware vsl pfc mode pfc3c
- platform hardware vsl pfc mode non-xl
- port-channel hash-distribution (virtual switch)
- port-channel load-defer
- port-channel port hash-distribution (virtual switch)
- port-channel port load-defer
- power enable (virtual switch)
- power redundancy-mode (virtual switch)
- remote command (virtual switch)
- remote login (virtual switch)
- service issu upgrade staggered
- session slot (virtual switch)
Virtual Switch Commands
attach (virtual switch)
To connect to a specific module from a remote location, use the attach command in privileged EXEC mode.
attach {slot | {switch num module num}}
Syntax Description
slot |
Slot number. |
switch num |
Specifies the switch to access; valid values are 1 and 2. |
module num |
Module number; see the "Usage Guidelines" section for valid values. |
Command Default
This command has no default settings.
Command Modes
Privileged EXEC (#)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
The valid values for module num depend on the chassis that is used. For example, if you have a 13-slot chassis, valid values for the module number are from 1 to 13.
This command is supported on DFC-equipped modules and the supervisor engine only.
When you execute the attach command, the prompt changes to Router-dfcx# or Switch-sp1# or Switch-sp2#, depending on the type of module to which you are connecting.
The attach (virtual switch) command is identical to the remote login (virtual switch) command.
There are two ways to end this session:
•You can enter the exit command as follows:
Router-dfc3# exit
[Connection to Switch closed by foreign host]
Router#
•You can press Ctrl-C three times as follows:
Router-dfc3# ^C
Router-dfc3# ^C
Router-dfc3# ^C
Terminate remote login session? [confirm] y
[Connection to Switch closed by local host]
Router#
Examples
The following example shows how to log in remotely to the DFC-equipped module:
Console (enable)#
attach switch 2 module 3
Trying Switch ...
Entering CONSOLE for Switch
Type "^C^C^C" to end this session
Router-dfc3#
Related Commands
|
|
---|---|
remote login (virtual switch |
Accesses the Catalyst 6500 series switch console or a specific module. |
clear mls acl counters (virtual switch)
To clear the MLS ACL counters, use the clear mls acl counters command in privileged EXEC mode.
clear mls acl counters [{interface interface switch/slot/port.subinterface} | {switch num} [module num]]
Syntax Description
Command Default
This command has no default settings.
Command Modes
Privileged EXEC (#)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
If you do not specify a switch or module number, the command applies to all switches and all modules.
This command is supported on Catalyst 6500 series switches that are configured with a WS-F6K-DFC3B-XL, release 2.1 and later.
Examples
The following example shows how to reset the MLS ACL counters in all interfaces and modules on a specific switch:
Router#
clear mls acl counters switch 1
Router#
Related Commands
|
|
---|---|
show tcam interface (virtual switch) |
Displays information about the interface-based TCAM. |
clear mls netflow (virtual switch)
To clear the MLS NetFlow-shortcut entries, use the clear mls netflow command in privileged EXEC mode.
clear mls netflow {ip | mpls} [switch num] [module mod]
Syntax Description
ip |
Clears IP MLS entries. |
switch num |
(Optional) Specifies the switch to access; valid values are 1 and 2. |
module mod |
(Optional) Specifies a module number. |
mpls |
Clears MPLS software-installed entries. |
Command Default
This command has no default settings.
Command Modes
Privileged EXEC (#)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
Usage Guidelines
If you do not specify a switch or module number, the command applies to both switches and all modules.
Examples
The following example shows how to clear all the entries that are associated with a specific module (2):
Router#
clear mls netflow ip switch 1 module 2
Router#
The following example shows how to clear the MPLS software-installed entries for all switches and modules:
Router#
clear mls netflow mpls
Router#
Related Commands
|
|
---|---|
show mls netflow ip switch (virtual switch) |
Displays information about the hardware NetFlow IP. |
clear mls statistics (virtual switch)
To reset the MLS statistics counters, use the clear mls statistics command in privileged EXEC mode.
clear mls statistics [switch num] [module num]
Syntax Description
switch num |
(Optional) Specifies the switch to access; valid values are 1 and 2. |
module num |
(Optional) Specifies the module number. |
Command Default
This command has no default settings.
Command Modes
Privileged EXEC (#)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
Usage Guidelines
If you do not specify a switch or module number, the command applies to both switches and all modules.
Examples
The following example shows how to reset the MLS statistics counters for all modules:
Router#
clear mls statistics switch 2
Router#
The following example shows how to reset the MLS statistics counters for a specific module:
Router#
clear mls statistics switch 2 module 5
Router#
Related Commands
|
|
---|---|
show mls statistics |
Displays the MLS statistics. |
dual-active detection (virtual switch)
To enable and configure dual-active detection, use the dual-active detection command in virtual switch configuration submode. To disable dual-active detection, use the no form of this command.
dual-active detection {bfd | pagp [trust channel-group num]} | fast-hello}
no dual-active detection {bfd | pagp | fast-hello}
Syntax Description
Command Default
Detection methods (bfd, pagp and fast-hello) are enabled and trust is disabled by default.
Command Modes
Virtual switch configuration submode (config-vs-domain)
Command History
Usage Guidelines
If PAgP is running on the MECs between the VSS and its access switches, the VSS can use enhanced PAgP messaging to detect dual-active scenario. The MEC must have links from both chassis of the VSS to the access switch. By default, PAgP dual-active detection is enabled. However, the enhanced messages are only sent on channel groups with trust mode enabled.
If you configure the fast hello dual-active detection mechanism, you must also configure dual-active interface pairs to act as fast hello dual-active messaging links. See the dual-active fast-hello (virtual switch) command.
When you enter the optional trust channel-group num keywords and argument, the following applies:
•You can configure trust mode on a port channel even if there are no interfaces on the port channel or the port channel is a protocol type other than PAgP. The trust mode status is displayed in the show pagp dual-active command output, but no interfaces are displayed.
•Configuring trust mode requires that the port channel exists. If the port channel does not exist, the following error message is displayed:
Router(config-vs-domain)# dual-active trust pagp channel-group 30
Port-channel 30 not configured
•If a trusted port is deleted, the trust-mode configuration is deleted and the following warning message is displayed:
Port-channel num is a trusted port-channel for PAgP
dual-active detection. Restricting this
port-channel has deleted the dual-active trust
channel-group configuration associated with it.
•If a trusted port is changed to a virtual switch port, the trust mode configuration is deleted when the port becomes restricted and the following warning message is displayed:
Port-channel num is a trusted port-channel for PAgP
dual-active detection. Deletion of this
port-channel has deleted the dual-active trust
channel-group configuration associated with it.
•If you enter the dual-active detection pagp trust port-channel command on a virtual switch port channel, the following error message is displayed:
Cannot configure dual-active trust mode on a virtual switch port-channel
Examples
The following example shows how to configure interfaces for PAgP dual-active detection:
Router(config)# switch virtual domain domain-id
Router (config-vs-domain)# dual-active detection pagp
Router (config-vs-domain)#
The following example shows how to specify that EtherChannel/port bundling to be used for PAgP dual-active detection;
Router(config)# switch virtual domain domain-id
Router (config-vs-domain)# dual-active detection pagp trust port-channel 20
Router (config-vs-domain)#
The following example shows how to configure an interface for fast hello dual-active detection:
Router(config)# switch virtual domain domain-id
Router (config-vs-domain)# dual-active detection fast-hello
Router (config-vs-domain)# exit
Router(config)# interface fastethernet 1/2/40
Router(config-if)# dual-active fast-hello
WARNING: Interface FastEthernet1/2/40 placed in restricted config mode. All extraneous
configs removed!
Router(config-if)# no shutdown
Related Commands
dual-active exclude (virtual switch)
To exclude the interface from shutdown during recovery, use the dual-active exclude command in virtual switch configuration submode. To return to the default settings, use the no form of this command.
dual-active exclude
no dual-active exclude
Syntax Description
This command has no arguments or keywords.
Command Default
Exclusion of the interface from shutdown during recovery is disabled by default.
Command Modes
Virtual switch configuration submode (config-vs-domain)
Command History
Usage Guidelines
When you configure the exclusion list, note the following information:
•The interface must be a physical port with an IP address.
•The interface must not be a VSL port.
•The interface must not be configured as a fast hello dual-active messaging link.
•The interface must not be in use for IP BFD dual-active detection.
•The interface must not be in use for fast hello dual-active detection.
Examples
The following example shows how to exclude the interface from shutdown during recovery:
Router(config)# switch virtual domain domain-id
Router (config-vs-domain)# dual-active exclude interface gigabitethernet 1/9/48
Router (config-vs-domain)#
dual-active fast-hello (virtual switch)
To enable an interface to be a fast hello dual-active messaging link, use the dual-active detection command in interface configuration mode. To disable dual-active detection on an interface, use the no form of this command.
dual-active fast-hello
no dual-active fast-hello
Syntax Description
This command has no arguments or keywords.
Command Default
Fast hello dual-active detection is disabled on all interfaces by default.
Command Modes
Interface configuration mode (config-if)
Command History
|
|
---|---|
12.2(33)SXI |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
This command automatically removes all other configuration from the interface and restricts the interface to dual-active configuration commands.
Examples
The following example shows how to configure an interfaceas a fast hello dual-active messaging link:
Router(config)# switch virtual domain domain-id
Router (config-vs-domain)# dual-active detection fast-hello
Router (config-vs-domain)# exit
Router(config)# interface fastethernet 1/2/40
Router(config-if)# dual-active fast-hello
WARNING: Interface FastEthernet1/2/40 placed in restricted config mode. All extraneous
configs removed!
Router(config-if)# no shutdown
Related Commands
fabric buffer-reserve (virtual switch)
To reserve ASIC buffers, use the fabric buffer-reserve command in global configuration mode. To return to the default settings, use the no form of this command.
[default] fabric {switch num} buffer-reserve [high | low | medium | queue | value]
no fabric {switch num} buffer-reserve
Syntax Description
Command Default
The default settings are as follows:
•Buffer reserve is set to 0x0.
•Two queues.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
Note Use this command only under the direction of Cisco TAC.
The fabric buffer-reserve queue command is supported on Catalyst 6500 series switches that are configured with the following modules:
•WS-X6748-GE-TX
•WS-X6724-SFP
•WS-X6748-SFP
•WS-X6704-10GE
Entering the default fabric buffer-reserve queue command is the same as entering the fabric buffer-reserve queue command.
You can enter the fabric buffer-reserve command to improve the system throughput by reserving ASIC buffers.
This command is supported on the following modules:
•WS-X6704-10GE
•WS-X6748-SFP
•WS-X6748-GE-TX
•WS-X6724-SFP
Examples
The following example shows how to reserve the high (0x5050) ASIC buffer spaces:
Router(config)# fabric switch 1 buffer-reserve high
Router(config)#
The following example shows how to reserve the low (0x3030) ASIC buffer spaces:
Router(config)# fabric switch 1 buffer-reserve low
Router(config)#
Related Commands
|
|
---|---|
show fabric |
Displays the information about the crossbar fabric. |
fabric clear-block (virtual switch)
To enable the clear-block congestion control for the fabric channels, use the fabric clear-block command in global configuration mode. To disable the clear-block congestion control for the fabric channels, use the no form of this command.
fabric {switch num} clear-block
no fabric {switch num} clear-block
Syntax Description
switch num |
Specifies the switch number; valid values are 1 and 2. |
Command Default
The clear-block congestion control for the fabric channels is disabled by default.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
Note Do not enter the fabric clear-block command unless TAC advises you to do so.
Examples
The following example shows how to enable the clear-block congestion control for the fabric channels:
Router(config)# fabric switch 1 clear-block
Router(config)#
The following example shows how to disable the clear-block congestion control for the fabric channels:
Router(config)# no fabric switch 1 clear-block
Router(config)#
Related Commands
|
|
---|---|
show fabric |
Displays the information about the crossbar fabric. |
fabric error-recovery fabric-switchover (virtual switch)
To enable a supervisor engine switchover when excessive fabric synchronization errors are detected on the fabric-enabled module, use the fabric error-recovery fabric-switchover command in global configuration mode. To disable the supervisor engine switchover for excessive fabric synchronization errors, use the no form of this command.
fabric {switch num} error-recovery fabric-switchover
no fabric {switch num} error-recovery fabric-switchover
Syntax Description
switch num |
Specifies the switch number; valid values are 1 and 2. |
Command Default
Excessive fabric synchronization errors initiate a supervisor engine switchover, and the configuration is not saved to the configuration file.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
When a fabric-capable switching module has fabric errors, a supervisor engine switchover is initiated.
You can use the no fabric error-recovery fabric-switchover command to avoid the supervisor engine switchover. This command does not perform the supervisor engine switchover but powers down the module that is experiencing the excessive fabric errors. This command is saved to the configuration file.
Examples
The following example shows how to enable a supervisor engine switchover when excessive fabric synchronization errors are detected on the fabric-enabled module:
Router(config)# fabric switch 2 error-recovery fabric-switchover
Router(config)#
The following example shows how to disable a supervisor engine switchover when excessive fabric synchronization errors are detected on the fabric-enabled module:
Router(config)# no fabric switch 2 error-recovery fabric-switchover
Router(config)#
Related Commands
|
|
---|---|
show fabric |
Displays the information about the crossbar fabric. |
fabric required (virtual switch)
To prevent the Catalyst 6500 series switch from coming online without a Switch Fabric Module, use the fabric required command in global configuration mode. To allow the Catalyst 6500 series switch to come up without a Switch Fabric Module, use the no form of this command.
fabric {switch num} required
no fabric {switch num} required
Syntax Description
switch num |
Specifies the switch number; valid values are 1 and 2. |
Command Default
A Switch Fabric Module is not required in the system to come online.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
If you enter the fabric required command, when you remove or power down the last Switch Fabric Module, all modules except the supervisor engine, power down. When you insert or power on the first Switch Fabric Module, the modules that were previously powered down power up if the Switch Fabric Module configuration is not in conflict with other configurations.
If you enter the no fabric required command, the modules will also power on if a Switch Fabric Module is not present and the configuration allows for it.
Examples
The following example shows how to prevent the Catalyst 6500 series switch from coming online without a Switch Fabric Module:
Router(config)#
fabric switch 1 required
Router(config)#
The following example shows how to allow the Catalyst 6500 series switch to come up without a Switch Fabric Module:
Router(config)#
no fabric switch 1 required
Router(config)#
Related Commands
|
|
---|---|
show fabric |
Displays the information about the crossbar fabric. |
fabric switching-mode allow (virtual switch)
To enable the truncated mode in the presence of two or more fabric-enabled switching modules, use the fabric switching-mode allow command in global configuration mode. To disable truncated mode, use the no form of this command.
fabric {switch num} switching-mode allow {bus-mode | dcef-only | {truncated [{threshold [mod]}]}}
no fabric {switch num} switching-mode allow {bus-mode | {truncated [threshold]}}
Syntax Description
Command Default
The truncated mode is disabled.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
Bus mode—The Catalyst 6500 series switch uses this mode for traffic between nonfabric-enabled modules and for traffic between a nonfabric-enabled module and a fabric-enabled module. In this mode, all traffic passes between the local bus and the supervisor engine bus.
dcef-only mode—Supervisor engines, both active and redundant, operate as nonfabric-capable modules with their Gigabit Ethernet ports relying on the PFC on the active supervisor engine for all forwarding decisions. The dcef-only mode disables the Gigabit Ethernet ports on the supervisor engines so that they do not operate as nonfabric-capable modules. If all other modules are operating in dCEF mode, module OIR is non-disruptive.
Truncated mode—The Catalyst 6500 series switch uses this mode for traffic between fabric-enabled modules when there are both fabric-enabled and non fabric-enabled modules installed. In this mode, the Catalyst 6500 series switch sends a truncated version of the traffic (the first 64 bytes of the frame) over the switch fabric channel.
Compact mode—The Catalyst 6500 series switch uses this mode for all traffic when only fabric-enabled modules are installed. In this mode, a compact version of the DBus header is forwarded over the switch fabric channel, which provides the best possible performance.
To prevent use of non fabric-enabled modules or to prevent fabric-enabled modules from using bus mode, enter the no fabric switching-mode allow bus-mode command.
The fabric switching-mode allow command affects Catalyst 6500 series switches that are configured with a minimum of two fabric-enabled modules.
You can enter the fabric switching-mode allow truncated command to unconditionally allow truncated mode.
You can enter the no fabric switching-mode allow truncated command to allow truncated mode if the threshold is met.
You can enter the no fabric switching-mode allow bus-mode command to prevent any module from running in bus-mode.
To return to the default truncated-mode threshold, enter the no fabric switching-mode allow truncated threshold command.
The valid value for mod is the threshold value.
Examples
The following example shows how to specify truncated mode:
Router(config)#
fabric switch 1 switching-mode allow truncated
Router(config)#
Related Commands
|
|
---|---|
show fabric |
Displays the information about the crossbar fabric. |
fabric switching-mode force bus-mode (virtual switch)
To force fabric-enabled modules into bus switching mode, use the fabric switching-mode force bus-mode command in global configuration mode. To power cycle the module to truncated mode, use the no form of this command.
fabric {switch num} switching-mode force bus-mode
no fabric {switch num} switching-mode force bus-mode
Syntax Description
switch num |
Specifies the switch number; valid values are 1 and 2. |
Command Default
This command has no default settings.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
This command applies to the following modules:
•WS-SVC-NAM-1—Network Analysis Module 1
•WS-SVC-NAM-2—Network Analysis Module 2
After you enter the fabric switching-mode force busmode or the no fabric switching-mode force busmode command, the fabric-enabled service modules power cycle immediately. The mode change occurs as the modules come up after the power cycle.
Examples
The following example shows how to force fabric-enabled modules into flow-through switching mode:
Router(config)#
fabric switch 1 switching-mode force bus-mode
Router(config)#
Related Commands
|
|
---|---|
show fabric |
Displays the information about the crossbar fabric. |
hw-module (virtual switch)
To specify the boot options for the module through the power management bus control register, use the hw-module command in privileged EXEC mode.
hw-module {switch num module num} {boot [value] {config-register | eobc | {flash image} | rom-monitor}}
Syntax Description
Command Default
This command has no default settings.
Command Modes
Privileged EXEC (#)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
The valid values for the boot value argument are as follows:
0—Specifies the module's config-register value.
1—Specifies the first image in the Flash memory.
2—Specifies the second image in the Flash memory.
3—Stays in ROM-monitor mode after the module reset.
4—Specifies the download image through EOBC.
Examples
The following example shows how to reload the module in slot 6 using the module's config-register value:
Router# hw-module slot switch 1 module 6 boot config-register
Router#
The following example shows how to reload the module in slot 3 using an image downloaded through EOBC:
Router# hw-module switch 1 module 6 boot eobc
Router#
interface (virtual switch)
To select an interface to configure and enter interface configuration mode, use the interface global configuration mode command.
interface {interface switch-num/slot/port.subinterface}
Syntax Description
interface |
Type of interface to be configured; see Table 1 for valid values. |
switch-num |
Switch ID |
slot |
Slot number. |
port |
Port number. |
.subinterface |
Port subinterface number to be configured. Range: 0 to 4294967295. |
Command Default
No interface types are configured.
Command Modes
Global configuration (config)
Command History
Usage Guidelines
Table 1 lists the valid values for type.
Examples
The following example shows how to enter the interface configuration mode on the GigabitEthernet interface for switch 1, module 2, port 4:
Router(config)# interface gigabitethernet 1/2/4
Router(config)#
Related Commands
|
|
---|---|
show interfaces (virtual switch) |
Displays the traffic that is seen by a specific interface. |
mac-address (virtual switch)
To specify a Media Access Control (MAC) address to use as the common router MAC address for interfaces on the active and standby chassis, use the mac-address virtual switch configuration submode command. To return to the default setting, use the no form of this command.
mac-address {mac-address | use-virtual}
Syntax Description
mac-address |
MAC address in hexadecimal format. |
use-virtual |
Specifies the MAC address range reserved for the virtual switch system (VSS). |
Command Default
The router MAC address is derived from the backplane of the active chassis.
Command Modes
Virtual switch configuration submode (config-vs-domain)
Command History
|
|
---|---|
12.2(33)SXH2 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
When a virtual switch comes up, the router MAC address is derived from the backplane of the active chassis and is used as the common router MAC address for interfaces on both the active and the standby chassis. Between switchovers, this MAC address is maintained on the new active switch. You can enter the mac-address mac-address command to specify a MAC address to use or the mac-address use-virtual to use the MAC address range reserved for the VSS.
The MAC address range reserved for the VSS is derived from a reserved pool of addresses with the domain ID encoded in the leading 6 bits of the last octet and trailing 2 bits of the previous octet of the mac-address. The last two bits of the first octet is allocated for protocol mac-address which is derived by adding the protocol ID (0 to 3) to the router MAC address.
Note You must reload the virtual switch for the new router MAC address to take effect. If the MAC address you configured is different from the current MAC address, the following message is displayed:Configured Router mac address is different from operational value. Change will take effect
after config is saved and switch is reloaded.
Examples
The following example shows how to specify the MAC address to use in hexadecimal format:
Router(config)# switch virtual domain test-mac-address
Router(config-vs-domain)# mac-address 0000.0000.0000
Router(config-vs-domain)#
The following example shows how to specify the MAC address range reserved for the VSS:
Router(config)# switch virtual domain test-mac-address
Router(config-vs-domain)# mac-address use-virtual
Router(config-vs-domain)#
Related Commands
|
|
---|---|
switch virtual domain |
Assigns a switch number and enters virtual switch domain configuration submode. |
mac-address-table learning (virtual switch)
To enable MAC-address learning on a VLAN, range of VLANs, or an interface, use the mac-address-table learning command in global configuration mode. To disable learning, use the no form of this command.
[default] mac-address-table learning {{vlan vlan-id | range} | {interface interface switch/slot/port}} [switch num] [module num]
no mac-address-table learning {{vlan vlan-id} | {interface interface switch/slot/port}} [switch num] [module num]
Syntax Description
Command Default
If you configure a VLAN on a port in a module, all the supervisor engines and DFCs in the Catalyst 6500 series switch are enabled to learn all the MAC addresses on the specified VLAN.
Command Modes
Global configuration
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
Note When you enable or disable MAC learning for a VLAN, you must also enable or disable MAC learning on any switching modules that hosts VSL ports.
You can use the vlan vlan-id keyword and argument on switch-port VLANs only. You cannot use the vlan vlan-id keyword and argument to configure learning on routed interfaces.
If you specify a range of VLANs, use the following guidelines:
•Enter a hyphen (-) to denote a range of VLANs, for example 24-35.
•Separate each entry with a comma (,), for example, 24, 48, 52-59, 62
You can use the interface interface slot/port keyword and arguments on routed interfaces, supervisor engines, and DFCs only. You cannot use the interface interface slot/port keyword and arguments to configure learning on switch-port interfaces or non-DFC modules.
Examples
The following example shows how to enable MAC-address learning on a switch-port interface on all modules:
Router (config)# mac-address-table learning vlan 100
Router (config)#
The following example shows how to enable MAC-address learning on a range of VLANs on all modules:
Router (config)# mac-address-table learning vlan 100-115,125
Router (config)#
The following example shows how to enable MAC-address learning on a switch-port interface on switch 1:
Router (config)# mac-address-table learning vlan 100 switch 1
Router (config)#
The following example shows how to disable MAC-address learning on a specified switch-port interface for all modules:
Router (config)# no mac-address-table learning vlan 100
Router (config)#
The following example shows how to enable MAC-address learning on a routed interface on all modules:
Router (config)# mac-address-table learning vlan 100
Router (config)#
The following example shows how to enable MAC-address learning on a routed interface for a specific module:
Router (config)# mac-address-table learning interface GigabitEthernet 3/48 switch 2 module
4
Router (config)#
The following example shows how to disable MAC-address learning for all modules on a specific routed interface:
Router (config)# no mac-address-table learning interface GigabitEthernet 3/48
Router (config)#
Related Commands
|
|
---|---|
show mac-address-table learning (virtual switch) |
Displays the MAC-address learning state. |
mls ip multicast egress fast-redirect
To enable fast-redirect optimization on any Layer 2 trunk multichassis EtherChannel or on a Distributed EtherChannel, use the mls ip multicast egress fast-redirect command in interface configuration mode. To disable fast-redirect optimization, use the no form of this command.
mls ip multicast egress fast-redirect
no mls ip multicast egress fast-redirect
Syntax Description
This command has no keywords or attributes.
Defaults
This command has no default settings.
Command Modes
Interface configuration mode (config-interface)
Command History
|
|
12.2(33)SXI4 |
Support for this command was introduced on the Supervisor Engine 720. |
Examples
This example shows how to enable a fast-redirect optimization on a Layer 2 multichassis EtherChannel:
Router(config)#
interface port-channel 4
Router(config-interface)#
mls ip multicast egress fast-redirect
Related Commands
|
|
---|---|
show mmls fast-redirect |
Displays the list of port channels, ports, and VLANs that have fast-redirect optimization enabled. |
module provision (virtual switch)
To provision modules on the virtual switching system (VSS), use the module provision command in global configuration mode. Use the no form of this command to return to the default settings.
module provision {switch num}
no module provision {switch num}
Syntax Description
switch num |
Specifies the number of the virtual switch chassis; valid values are 1 and 2. |
Command Default
first-insert
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
When you convert two standalone chassis into a VSS, modules on the standby chassis are auto-provisioned onto the active chassis. For additional information, see Chapter 4, "Converting Between Standalone Mode and the Virtual Switch Mode" of the Virtual Switch Cisco IOS Software Configuration Guide.
Once you enter the module provisioning configuration submode, the prompt changes to Router (config-prov-switch)# and the following commands are available:
•default—Sets a command to its defaults
•exit—Exits the module provisioning configuration submode and returns to the global configuration mode.
•no—Negates a command or sets its defaults
•slot—Specifies the module number and allows you to configure module provisioning using the following syntax:
slot number slot-type type port-type port-type number total-ports virtual-slot slot-num
slot number slot-type type vdb-type vdb-type port-type port-type number total-ports virtual-slot slot-num
For The following example, slot 3 slot-type 227 port-type 60 number 8 virtual-slot 19, the following applies:
•The slot-type is the VSL module type and the value 227 translates into the 8-port 10GE module (WS-X6708-10G-3C).
•The port-type of 60 indicates 10GE ports found on the 8-port 10GE module.
•The number 8 is the number of ports found on the actual module.
•The virtual-slot slot-num keyword and argument is calculated as (Switch # * 16) + Slot #.
So in this case, 19 is calculated as 1 * 16 + 3 = 19
For additional information, see Chapter 4, "Converting Between Standalone Mode and the Virtual Switch Mode" of the Virtual Switch Cisco IOS Software Configuration Guide for the recommended method for copying the configuration from the active chassis to the standby chassis.
Examples
The following example shows how to enter the module provisioning configuration submode:
Router(config)#
module provision switch 2
Router (config-prov-switch)#
These examples shows how to configure module provisioning:
Router(config)#
module provision switch 2
Router (config-prov-switch)#
slot 3 slot-type 227 port-type 60 number 8 virtual-slot 19
Router (config-prov-switch)#
Related Commands
|
|
---|---|
show module provision switch |
Displays the module provisioning status. |
monitor session servicemodule (virtual switch)
To start a new ERSPAN, SPAN, or RSPAN session, add or delete interfaces or VLANs to or from an existing session, filter ERSPAN, SPAN, or RSPAN traffic to specific VLANs, or delete a session, use the monitor session command in global configuration mode. To remove one or more source or destination interfaces from the session, remove a source VLAN from the session, or delete a session, use the no form of this command.
monitor session servicemodule switch num module mod-list
no monitor session servicemodule switch num module mod-list
Syntax Description
switch num |
Specifies the chassis number; valid values are 1 and 2. |
module mod-list |
Specifies the list of modules to be monitored. |
Command Default
All service modules are allowed to use the SPAN service module session.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
Note Be careful when configuring SPAN-type source ports that are associated to SPAN-type destination ports because you do not configure SPAN on high-traffic interfaces. If you configure SPAN on high-traffic interfaces, you may saturate fabric channels, replication engines, and interfaces. To configure SPAN-type source ports that are associated to SPAN-type destination ports, enter the monitor session session source {{interface type} | {{vlan vlan-id} [rx | tx | both]} | {remote vlan rspan-vlan-id}} command.
The local SPAN, RSPAN, and ERSPAN session limits are as follows:
|
|
|
|
---|---|---|---|
66 |
2 (ingress or egress or both) |
64 |
23 |
The local SPAN, RSPAN, and ERSPAN source and destination limits are as follows:
A particular SPAN session can either monitor the VLANs or monitor individual interfaces—you cannot have a SPAN session that monitors both specific interfaces and specific VLANs. If you first configure a SPAN session with a source interface, and then try to add a source VLAN to the same SPAN session, you get an error. You also get an error if you configure a SPAN session with a source VLAN and then try to add a source interface to that session. You must first clear any sources for a SPAN session before switching to another type of source.
The show monitor command displays the SPAN servicemodule session only if it is allocated in the system. It also displays a list of allowed modules and a list of active modules that can use the servicemodule session.
Only the no form of the monitor session servicemodule command is displayed when you enter the show running-config command.
If no module is allowed to use the servicemodule session, the servicemodule session is automatically deallocated. If at least one module is allowed to use the servicemodule session and at least one module is online, the servicemodule session is automatically allocated.
If you allow or disallow a list of modules that are not service modules from using the servicemodule session, there will be no effect on the allocation or deallocation of the servicemodule session. Only the list of modules is saved in the configuration.
If you disable the SPAN servicemodule session with the no monitor session servicemodule command, allowing or disallowing a list of modules from using the servicemodule session has no effect on the allocation or deallocation of the servicemodule session. Only the list of modules is saved in the configuration.
The monitor session servicemodule command is accepted even if there are no modules physically inserted in any slot.
Examples
The following example shows how to allow a list of modules to use the SPAN servicemodule session:
Router(config)# monitor session servicemodule switch 1 module 1-2
Router(config)#
The following example shows how to disallow a list of modules from using the SPAN servicemodule session:
Router(config)# no monitor session servicemodule switch 1 module 1-2
Router(config)#
Related Commands
|
|
---|---|
remote span |
Configures a VLAN as an RSPAN VLAN. |
show monitor session |
Displays information about the ERSPAN, SPAN, and RSPAN sessions. |
platform hardware vsl pfc mode pfc3c
To configure the system to operate in PFC3C mode after the next reload, use the platform hardware vsl pfc mode pfc3c command in global configuration mode. To return to the default settings, us e the no form of this command.
platform hardware vsl pfc mode pfc3c
no platform hardware vsl pfc mode pfc3c
Syntax Description
This command has no arguments or keywords.
Command Default
The default PFC mode is PFC3CXL.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
After entering this command, you must perform a system reload before the command takes affect.
If both supervisor engines have PFC3Cs installed, the VSS automatically operates in PFC3C mode, even if there are switching modules equipped with (DFC) 3CXL daughter cards.
If both supervisor engines have PFC3CXLs installed and there is a combination of DFC3C and DFC3CXL switching modules, the system PFC mode is dependant on how the 3C and 3CXL switching modules are distributed between the two chassis.
Each chassis in the VSS determines its system PFC mode. If there is a mismatch between the PFC modes on both chassis, the VSS comes up in RPR mode instead of SSO mode.
Examples
The following example shows how to configure the system to operate in PFC3C mode after the next reload;
Router(config)# platform hardware vsl pfc mode pfc3c
Router(config)#
Related Commands
|
|
---|---|
show power |
Displays platform information. |
platform hardware vsl pfc mode non-xl
To configure the system to operate in PFC4C mode when you reload, use the platform hardware vsl pfc mode non-xl command in global configuration mode. To return to the default settings, use the no form of this command.
platform hardware vsl pfc mode non-xl
no platform hardware vsl pfc mode non-xl
Syntax Description
This command has no arguments or keywords.
Command Default
The default PFC mode is PFC4CXL.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(50)SY |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
After entering this command, you must perform a system reload before the command takes affect.
If both supervisor engines have PFC4Cs installed, the VSS automatically operates in PFC4C mode, even if there are switching modules equipped with (DFC) 4CXL daughter cards.
If both supervisor engines have PFC4CXLs installed and there is a combination of DFC4C and DFC4CXL switching modules, the system PFC mode is dependant on how the 4C and 4CXL switching modules are distributed between the two chassis.
Each chassis in the VSS determines its system PFC mode. If there is a mismatch between the PFC modes on both chassis, the VSS comes up in RPR mode instead of SSO mode.
Examples
The following example shows how to configure the system to operate in PFC4C mode when you reload:
Router(config)# platform hardware vsl pfc mode non-xl
Router(config)#
port-channel hash-distribution (virtual switch)
To set the hash distribution algorithm method, use the port-channel hash-distribution command in global configuration mode. To return to the default settings, use the no or default form of this command.
port-channel hash-distribution {adaptive | fixed}
{no | default} port-channel hash-distribution
Syntax Description
Command Default
The default setting is fixed.
In Cisco IOS Release 12.2(50)SY or later releases, the hash distribution algorithm method is set to adaptive.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
The EtherChannel load distribution algorithm uses a register (the bundle select register) in the port ASIC to determine the port for each outgoing packet. When you use the fixed algorithm and you add a port to the EtherChannel or delete a port from the EtherChannel, the switch updates the bundle select register for each port in the EtherChannel. This causes a short outage on each port.
When you use the adaptive algorithm, The adaptive algorithm does not require the bundle select register to be changed for existing member ports.
Note When you change the algorithm, the change is applied at the next member link event. Example events include link down, up, addition, deletion, no shutdown, and shutdown. When you enter the command to change the algorithm, the command console issues a warning that the command does not take effect until the next member link event
Examples
The example shows how to set the hash distribution algorithm method to adaptive:
Router(config)# port-channel hash adaptive
Router(config)#
port-channel load-defer
To configure the port load share deferral interval for all port channels, use the port-channel load-defer command in global configuration mode. To reset the port defer interval to the default setting, use the no form of this command.
port-channel load-defer seconds
no port-channel load-defer seconds
Syntax Description
seconds |
Sets the time interval in seconds by which load sharing will be deferred on the switch. Valid range is from 1 to 1800 seconds. The default deferal interval is 120 seconds |
Defaults
The port defer interval is 120 seconds.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
To reduce data loss following a stateful switchover (SSO), port load share deferral can be enabled by entering the port-channel port load-defer command on a port channel of a switch that is connected by a multichassis EtherChannel (MEC) to a virtual switching system (VSS). Port load share deferral temporarily prevents the switch from forwarding data traffic to MEC member ports on a failed chassis of the VSS while the VSS recovers from the SSO.
The load share deferral interval is determined by a single global timer configurable by the port-channel load-defer command. After an SSO switchover, a period of several seconds to several minutes can be required for the reinitialization of line cards and the reestablishment of forwarding tables, particularly multicast topologies.
The valid range of seconds is 1 to 1800 seconds; the default is 120 seconds.
Examples
This example shows how to set the global port deferral interval to 60 seconds:
Router(config)#
port-channel load-defer 60
Router(config)#
This example shows how to verify the configuration of the port deferral interval on a port channel:
Router# show etherchannel 50 port-channel
Port-channels in the group:
----------------------
Port-channel: Po50 (Primary Aggregator)
------------
Age of the Port-channel = 0d:00h:22m:20s
Logical slot/port = 46/5 Number of ports = 3
HotStandBy port = null
Port state = Port-channel Ag-Inuse
Protocol = LACP
Fast-switchover = disabled
Load share deferral = enabled defer period = 60 sec time left = 57 sec
Router#
Related Commands
port-channel port hash-distribution (virtual switch)
To configure the port hash-distribution method, use the port-channel port hash-distribution command in interface configuration mode. To return to the default settings, use the no or default form of this command.
port-channel port hash-distribution {adaptive | fixed}
{no | default} port-channel port hash-distribution
Syntax Description
Command Default
For non-VSL EtherChannel groups the default setting is fixed.
For VSL EtherChannel groups the default setting is adaptive.
Command Modes
Interface configuration (config-if)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
The adaptive port-channel method is not supported on virtual switch port channels.
The EtherChannel load distribution algorithm uses a register (the bundle select register) in the port ASIC to determine the port for each outgoing packet. When you use the fixed algorithm and you add a port to the EtherChannel or delete a port from the EtherChannel, the switch updates the bundle select register for each port in the EtherChannel. This causes a short outage on each port.
When you use the adaptive algorithm, The adaptive algorithm does not require the bundle select register to be changed for existing member ports.
Note When you change the algorithm, the change is applied at the next member link event. Example events include link down, up, addition, deletion, no shutdown, and shutdown. When you enter the command to change the algorithm, the command console issues a warning that the command does not take effect until the next member link event
Examples
The example shows how to set the hash distribution algorithm method to fixed:
Router(config-if)# port-channel port hash-distribution fixed
Router(config)#
port-channel port load-defer
To enable the temporary deferral of port load sharing during the connection or reconnection of a port channel, use the port-channel port load-defer command in interface configuration mode. To disable the deferral of port load sharing on a port channel, use the no form of this command.
port-channel port load-defer
no port-channel port load-defer
Syntax Description
This command has no keywords or arguments.
Defaults
The port load share deferral feature is not enabled on a port channel.
Command Modes
Interface configuration (config-if)
Command History
|
|
---|---|
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
To reduce data loss following a stateful switchover (SSO), a port load share deferral can be enabled on a port channel of a switch that is connected by a multichassis EtherChannel (MEC) to a virtual switching system (VSS). The load share deferral interval prevents the switch from forwarding data traffic to MEC member ports on a failed chassis of the VSS while the VSS recovers from the SSO.
When load share deferral is enabled on a port channel, the assignment of a member port's load share is delayed for a period that is configurable globally by the port-channel load-defer command. During the deferral period, the load share of a deferred member port is set to 0. In this state, the deferred port is capable of receiving data and control traffic, and of sending control traffic, but the port is prevented from sending data traffic over the MEC to the VSS. Upon expiration of the global deferral timer, the deferred member port exits the deferral state and the port assumes its normal configured load share.
Load share deferral is applied only if at least one other member port of the port channel is currently active with a nonzero load share. If a port enabled for load share deferral is the first member bringing up the EtherChannel, the deferral feature does not apply and the port will forward traffic immediately.
The load share deferral interval is determined by a single global timer configurable from 1 to 1800 seconds by the port-channel load-defer command. The default interval is 120 seconds. After an SSO switchover, a period of several seconds to several minutes can be required for the reinitialization of line cards and the reestablishment of forwarding tables, particularly multicast topologies.
Examples
This example shows how to enable the load share deferral feature on port channel 50 of a switch that is an MEC peer to a VSS:
Router(config)#
interface port-channel 50
Router(config-if)#
port-channel port load-defer
This will enable the load share deferral feature on this port-channel.
The port-channel should connect to a Virtual Switch (VSS).
Do you wish to proceed? [yes/no]:
yes
Router(config-if)#
This example shows how to verify the state of the port deferral feature on a port channel:
Router# show etherchannel 50 port-channel
Port-channels in the group:
----------------------
Port-channel: Po50 (Primary Aggregator)
------------
Age of the Port-channel = 0d:00h:22m:20s
Logical slot/port = 46/5 Number of ports = 3
HotStandBy port = null
Port state = Port-channel Ag-Inuse
Protocol = LACP
Fast-switchover = disabled
Load share deferral = enabled defer period = 120 sec time left = 57 sec
Router#
power enable (virtual switch)
To turn on power for the modules, use the power enable command in global configuration mode. Use the no form of this command to power down a module.
power enable {switch num} {module slot}
no power enable {switch num} {module slot}
Syntax Description
switch num |
Specifies the switch where the module resides; valid values are 1 and 2. |
module slot |
Specifies a module slot number; see the "Usage Guidelines" section for valid values. |
Command Default
Power to the modules is turned on by default.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
When you power down a module, the module's configuration is not saved.
When you power down an empty slot, the configuration is saved.
The slot argument designates the module number. Valid values for slot depend on the switch that is used. For example, if you have a 13-slot switch, valid values for the module number are from 1 to 13.
Examples
The following example shows how to turn on the power for a module that was previously powered down:
Router(config)#
power enable switch 1 module 5
Router(config)#
The following example shows how to power down a module:
Router(config)#
no power enable switch 2 module 5
Router(config)#
Related Commands
|
|
---|---|
show power |
Displays information about the power status |
power redundancy-mode (virtual switch)
To set the power-supply redundancy mode, use the power redundancy-mode command in global configuration mode.
power redundancy-mode {combined | redundant} switch num
Syntax Description
Command Default
The default setting is redundant.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Examples
The following example shows how to set the power supplies to the no-redundancy mode:
Router(config)#
power redundancy-mode combined switch 1
Router(config)#
The following example shows how to set the power supplies to the redundancy mode:
Router(config)#
power redundancy-mode redundant switch 2
Router(config)#
Related Commands
|
|
---|---|
show power |
Displays information about the power status |
remote command (virtual switch)
To execute a Catalyst 6500 series switch command directly on the switch console or a specified module without having to log into the Catalyst 6500 series switch first, use the remote command command in privileged EXEC mode.
remote command switch num {module num} command
remote command {{module num} | standby-rp | standby-sp | switch} command
Syntax Description
switch num |
Specifies the switch to access; valid values are 1 and 2. |
module num |
Specifies the module to access; see the "Usage Guidelines" section for valid values. |
command |
Command to be executed. |
Command Default
This command has no default settings.
Command Modes
Privileged EXEC (#)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
The module num keyword and argument designate the module number. Valid values depend on the chassis that is used. For example, if you have a 13-slot chassis, valid values are from 1 to 13.
When you execute the remote command switch-id command, the prompt changes to Switch-sp1# or Switch-sp2#.
This command is supported on DFC-equipped modules and the supervisor engine only.
This command does not support command completion, but you can use shortened forms of the command (for example, entering sh for show).
Examples
The following example shows how to execute the show calendar command from the standby route processor:
Router#
remote command standby-sp show calendar
Switch-sp1#
09:52:50 UTC Mon Feb 12 2007
Router#
Related Commands
|
|
---|---|
remote login (virtual switch) |
Accesses the Catalyst 6500 series switch console or a specific module. |
remote login (virtual switch)
To access the Catalyst 6500 series switch console or a specific module, use the remote login command in privileged EXEC mode.
remote login switch num {module num}
remote login {{module num} | standby-rp | standby-sp | switch | {switch num}}
Syntax Description
Command Default
This command has no default settings.
Command Modes
Privileged EXEC (#)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
The module num keyword and argument designate the module number. Valid values depend on the chassis that is used. For example, if you have a 13-slot chassis, valid values are from 1 to 13. The module num keyword and argument are supported on DFC-equipped modules and the standby supervisor engine only.
When you execute the remote login module num command, the prompt changes to Router-dfcx# or Switch-sp1# or Switch-sp2#, depending on the type of module to which you are connecting.
When you execute the remote login standby-rp command, the prompt changes to Router-sdby#.
When you execute the remote login switch-id command, the prompt changes to Switch-sp1# or Switch-sp2#.
The remote login module num command is identical to the attach (virtual switch) command.
There are two ways to end the session:
•You can enter the exit command as follows:
Switch-sp# exit
[Connection to Switch closed by foreign host]
Router#
•You can press Ctrl-C three times as follows:
Switch-sp1# ^C
Switch-sp1# ^C
Switch-sp1# ^C
Terminate remote login session? [confirm] y
[Connection to Switch closed by local host]
Router#
Examples
The following example shows how to perform a remote login to a specific module:
Router# remote login switch-id 1 module 1
Trying Switch ...
Entering CONSOLE for Switch
Type "^C^C^C" to end this session
Switch-sp1#
The following example shows how to perform a remote login to the Catalyst 6500 series active chassis switch processor:
Router# remote login switch
Trying Switch ...
Entering CONSOLE for Switch
Type "^C^C^C" to end this session
Switch-sp1#
The following example shows how to perform a remote login to the standby route processor:
Router# remote login switch-id 1 module 4
Trying Switch ...
Entering CONSOLE for Switch
Type "^C^C^C" to end this session
Router-sdby1#
Related Commands
|
|
---|---|
attach |
Connects to a specific module from a remote location. |
service issu upgrade staggered
To stop using the staggered upgrade mode, use the no service issu upgrade staggered command in Global configuration mode.
service issu upgrade staggered
no service issu upgrade staggered
Syntax Description
This command has no keywords or arguments.
Command Default
The default setting is staggered.
Command Modes
Global configuration (config)
Command History
|
|
---|---|
15.1(1)SY |
Support for this command was introduced. |
Usage Guidelines
The no service issu upgrade staggered command allows you to opt-out of the staggered mode upgrade process.
Examples
The following example shows how to stop using the staggered upgrade mode:
Router# no service issu upgrade staggered
Router#
session slot (virtual switch)
To open a session with a module (for example, the NAM), use the session slot command in EXEC mode.
session switch num slot num processor processor-id
Syntax Description
switch num |
Specifies the switch to access; valid values are 1 and 2. |
slot num |
Slot number of the module. |
processor processor-id |
Specifies the processor ID number. Range: 0 to 9. |
Command Default
This command has no default settings.
Command Modes
EXEC (>)
Command History
|
|
---|---|
12.2(33)SXH1 |
Support for this command was introduced. |
12.2(50)SY |
Support for this command was introduced. |
15.0(1)SY |
Support for this command was introduced. |
Usage Guidelines
To end the session, enter the quit command.
This command allows you to use the module-specific CLI.
Examples
The following example shows how to open a session with module 4:
Router# session switch-id 2 slot 4 processor 2
Router#