The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This document describes a specific hardware issue on Fabric and storage Card (FSC) on Cisco Aggregrated Service Routers (ASR) 5500.
******** Show alarm outstanding verbose ******* Severity Object Timestamp Alarm ID -------- ---------- ---------------------------------- --------------------- Alarm Details ------------------------------------------------------------------------------------------------------------------------------------ Minor Card 14 Sunday August 21 07:16:34 A 3610743104839221248 The Fabric & 2x200GB Storage Card in slot 14 is a single point of failure. Another Fabric & 2x200GB Storage Card of the same type is needed. Minor Card 15 Sunday August 21 07:16:34 A 3610743104839221249 The Fabric & 2x200GB Storage Card in slot 15 is a single point of failure. Another Fabric & 2x200GB Storage Card of the same type is needed. Minor Card 17 Sunday August 21 07:16:34 A 3610743104839221250 The Fabric & 2x200GB Storage Card in slot 17 is a single point of failure. Another Fabric & 2x200GB Storage Card of the same type is needed.
******** show card table all ******* Slot Card Type Oper State SPOF Attach ----------- -------------------------------------- ------------- ---- ------ 1: DPC Data Processing Card Active No 2: DPC Data Processing Card Active No 3: DPC Data Processing Card Active No 4: DPC Data Processing Card Active No 5: MMIO Management & 20x10Gb I/O Card Active No 6: MMIO Management & 20x10Gb I/O Card Standby - 7: DPC Data Processing Card Active No 8: DPC Data Processing Card Active No 9: DPC Data Processing Card Active No 10: DPC Data Processing Card Standby - 11: SSC System Status Card Active No 12: SSC System Status Card Active No 13: FSC None - - 14: FSC Fabric & 2x200GB Storage Card Active Yes 15: FSC Fabric & 2x200GB Storage Card Active Yes 16: FSC Fabric & 2x200GB Storage Card Active No 17: FSC Fabric & 2x200GB Storage Card Active Yes
******** show hd raid verbose ******* HD RAID: State : Available (active) Degraded : Yes <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< UUID : 59a7ebf0:7f798af6:68869614:3210b2c6 Size : 1.2TB (1200000073728 bytes) Action : Idle Card 16 State : Faulty card <<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Description : FSC16 SAD17160089 Size : 400GB (400096755712 bytes) Disk hd16a State : In-sync component Created : Fri May 23 23:05:53 2014 Updated : Fri May 23 23:05:53 2014 Events : 0 Model : STEC Z16IZF2E-200UCU E4TC Serial Number : STM000171E75 Size : 200GB (200049647616 bytes) Disk hd16b State : In-sync component Created : Fri May 23 23:05:53 2014 Updated : Fri May 23 23:05:53 2014 Events : 0 Model : STEC Z16IZF2E-200UCU E4TC Serial Number : STM000171E8B Size : 200GB (200049647616 bytes)
These errors are reported when you start the troubleshoot with syslogs.
[local-60sec34.188] [hdctrl 132011 critical] [5/0/7135 <hdctrl:0> rl_fsm_mirror.c:5938] [software internal system critical-info syslog] hd16, FSC16 SAD17160089 failed from RAID 59a7ebf0:7f798af6:68869614:3210b2c6, MIO5 SAD1716021N. [local-60sec34.188] [hdctrl 132016 error] [5/0/7135 <hdctrl:0> rl_fsm_mirror.c:3399] [software internal system critical-info syslog] Error detected on hd16a (STEC Z16IZF2E-200UCU E4TC STM000171E75), FSC16 SAD17160089: ioerr_cnt increased from 25 to 27 [local-60sec34.221] [alarmctrl 65201 info] [5/0/7072 <evlogd:0> alarmctrl.c:192] [software internal system critical-info syslog] Alarm condition: id 321befb92b220000 (Minor): The Fabric & 2x200GB Storage Card in slot 14 is a single point of failure. Another Fabric & 2x200GB Storage Card of the same type is needed. [local-60sec34.222] [alarmctrl 65201 info] [5/0/7072 <evlogd:0> alarmctrl.c:192] [software internal system critical-info syslog] Alarm condition: id 321befb92b220002 (Minor): The Fabric & 2x200GB Storage Card in slot 17 is a single point of failure. Another Fabric & 2x200GB Storage Card of the same type is needed. [local-60sec34.222] [alarmctrl 65201 info] [5/0/7072 <evlogd:0> alarmctrl.c:192] [software internal system critical-info syslog] Alarm condition: id 321befb92b220001 (Minor): The Fabric & 2x200GB Storage Card in slot 15 is a single point of failure. Another Fabric & 2x200GB Storage Card of the same type is needed.
If you see this error log:
Aug 21 07:16:34 evlogd: [local-60sec34.188] [hdctrl 132016 error] [5/0/7135 <hdctrl:0> rl_fsm_mirror.c:3399] [software internal system critical-info syslog] Error detected on hd16a (STEC Z16IZF2E-200UCU E4TC STM000171E75), FSC16 SAD17160089: ioerr_cnt increased from 25 to 27
It is always advisable to run the smart test and check if this issue is not related to high temperature.
[local]# show hd smart hd16a smartctl 6.1 2013-03-16 r3800 [x86_64-linux-2.6.38-staros-v3-hw-64] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: STEC Product: Z16IZF2E-200UCU Revision: E4TC User Capacity: 200,049,647,616 bytes [200 GB] Logical block size: 512 bytes LU is resource provisioned, LBPRZ=1 Rotation Rate: Solid State Device Form Factor: 2.5 inches Logical Unit id: 0x5000a72030079304 Serial number: STM000171E75 Device type: disk Transport protocol: SAS Local Time is: Mon Aug 22 16:49:11 2016 AST SMART support is: Available - device has SMART capability. SMART support is: Enabled Temperature Warning: Enabled === START OF READ SMART DATA SECTION === SMART Health Status: OK SS Media used endurance indicator: 0% Current Drive Temperature: 52 C Drive Trip Temperature: 75 C local]SAE-G168A-1# show hd smart hd16b smartctl 6.1 2013-03-16 r3800 [x86_64-linux-2.6.38-staros-v3-hw-64] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Vendor: XXXX Product: Z16IZF2E-200UCU Revision: E4TC User Capacity: 200,049,647,616 bytes [200 GB] Logical block size: 512 bytes LU is resource provisioned, LBPRZ=1 Rotation Rate: Solid State Device Form Factor: 2.5 inches Logical Unit id: 0x5000a7203007932c Serial number: STM000171E8B Device type: disk Transport protocol: SAS Local Time is: Mon Aug 22 16:49:21 2016 AST SMART support is: Available - device has SMART capability. SMART support is: Enabled Temperature Warning: Enabled === START OF READ SMART DATA SECTION === SMART Health Status: OK SS Media used endurance indicator: 0% Current Drive Temperature: 50 C Drive Trip Temperature: 75 C
Since the smart test is ok you can conclude its not related to high temperature issue.
Sometimes one or both the drives on a single FSC moves to Invalid Partition or image state.
This could happen if Super Capacitor is failed which is in the drive of a single FSC. This failure cannot be recovered as it is a permanent drive failure where either the drive is replaced or the FSC.
Please contact Cisco TAC for further assistance.
If this is seen for any drive, there is a super capacitor failure on that drive.
These logs are seen in the debug console logs of active Management Input/Output card (MIO).
2016-Aug-21+07:16:34.038 card 5-cpu0: [974499.606697] sd 0:0:2:0: [sde] Unhandled sense code^M 2016-Aug-21+07:16:34.139 card 5-cpu0: [974499.611565] sd 0:0:2:0: [sde] Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE^M 2016-Aug-21+07:16:34.139 card 5-cpu0: [974499.618877] sd 0:0:2:0: [sde] Sense Key : Data Protect [current] ^M 2016-Aug-21+07:16:34.139 card 5-cpu0: [974499.625214] sd 0:0:2:0: [sde] Add. Sense: Write protected^M 2016-Aug-21+07:16:34.139 card 5-cpu0: [974499.630840] sd 0:0:2:0: [sde] CDB: Write(10): 2a 00 00 00 08 08 00 00 08 00^M 2016-Aug-21+07:16:34.139 card 5-cpu0: [974499.638173] end_request: I/O error, dev sde, sector 2056^M 2016-Aug-21+07:16:34.139 card 5-cpu0: [974499.643558] md: super_written gets error=-5, uptodate=0^M 2016-Aug-21+07:16:34.139 card 5-cpu0: [974499.648872] md/raid:md0: Disk failure on md16, disabling device.^M 2016-Aug-21+07:16:34.139 card 5-cpu0: [974499.648873] md/raid:md0: Operation continuing on 3 devices.^M 2016-Aug-21+07:16:34.238 card 5-cpu0: [974499.712047] sd 0:0:2:0: [sde] Sense Key : Recovered Error [current] ^M 2016-Aug-21+07:16:34.238 card 5-cpu0: [974499.718637] sd 0:0:2:0: [sde] <<vendor>> ASC=0x80 ASCQ=0x0ASC=0x80 ASCQ=0x0^M 2016-Aug-21+07:21:37.112 card 5-cpu0: [974802.605115] sd 0:0:2:0: [sde] Sense Key : Recovered Error [current] ^M 2016-Aug-21+07:21:37.112 card 5-cpu0: [974802.611712] sd 0:0:2:0: [sde] <<vendor>> ASC=0x80 ASCQ=0x0ASC=0x80 ASCQ=0x0^M 2016-Aug-21+07:26:37.099 card 5-cpu0: [975102.612464] sd 0:0:2:0: [sde] Sense Key : Recovered Error [current] ^M
Please check particular error logs in
And this confirms supercapacitor failure.
**** debug console card <Active MIO card> cpu 0 tail 10000 only ***** [sde] <> ASC=0x80 ASCQ=0x0ASC=0x80 ASCQ=0x0 ******** debug hdctrl history ******* Thursday March 31 02:29:03 EDT 2016 Primary HDCTRL: 2016-Mar-31+02:13:38.632 move fsm=hd15#6 src=DISK_CHECK dst=DISK_FAILED arg=disk I/O error # hdctrl/hdctrl_fsm_disk.c : 4354 @ disk_fsm_enter()
Below is the mapping of the disks to device name:
******** debug hdctrl mapping ******* Local card (5): Disk Device Number SCSI Size ---------- ------ ------ ------- ------ hd14a sdb 8:16 0:0:0:0 186 GB hd15a sdd 8:48 0:0:1:0 186 GB hd16a sde 8:64 0:0:2:0 186 GB hd17a sdg 8:96 0:0:3:0 186 GB hd14b sda 8:0 1:0:0:0 186 GB hd15b sdc 8:32 1:0:1:0 186 GB hd16b sdf 8:80 1:0:2:0 186 GB hd17b sdh 8:112 1:0:3:0 186 GB
Below highlated logs indicating a failure of the super capacitor on the solid state drive of FSC card disk 16a.
hd16a <==>sde
-------------
2016-Aug-21+07:21:37.112 card 5-cpu0: [974802.611712] sd 0:0:2:0: [sde] <<vendor>> ASC=0x80 ASCQ=0x0ASC=0x80 ASCQ=0x0^M
2016-Aug-21+07:26:37.099 card 5-cpu0: [975102.612464] sd 0:0:2:0: [sde] Sense Key : Recovered Error [current] ^M