Wide Area Virtualization Engine Hardware Specifications
This appendix provides hardware specifications for the Wide Area Virtualization Engine (WAVE) 274 and 474 appliances. It contains the following sections:
•Inline Adapter Specifications
Appliance Specifications
Table A-1 provides a summary of the features and specifications of the WAVE-274 and WAVE-474.
|
|
---|---|
Microprocessor |
•Intel Core2 Duo E6400 Processor, 2.13-GHz •2 MB Level 2 cache •1066-MHz front-side bus (FSB) |
Memory |
•3 GB DDR2 Synch DRAM |
Drives standard |
•DVD-ROM/CD-RW combination drive •250 GB SATA 3.0 Gb/s, 7200 rpm |
Size |
•Height: 3.94 in. (10.0 cm) •Depth: 15.0 in. (38.0 cm) •Width: 13.4 in. (34.0 mm) |
Weight |
18.6 lb (8.4 kg) typical |
Ports |
•USB: 6 USB 2.0 (2 front, 4 rear) •Console: 2 RS232 serial ports individually configurable to power 5 V and 12 V. COM1 can be configured for 5 V, 9 V, and 12 V •Parallel: 1 •PS/2: 2 •Video: 1 •Audio: 2, line in and line out •NIC: RJ-45 •Inline Network Adapter: 2 (see Inline Adapter Specifications) |
Power |
•Operating Voltage Range: 90 to 264 VAC •Rated Voltage Range: 100 to 240 VAC •Rated Line Frequency: 50/60 Hz •Operating Line Frequency Range: 47 - 63 Hz •Rated Input Current: 5 A @ 90 VAC (3.5 A at 90 VAC with 80% efficient power supply) •Heat Dissipation: typical 273 btu/hr (69 kg-cal/hr), maximum 1024 btu/hr (258 kg-cal/hr) •Power Supply Fan: 80 mm variable speed fan |
Environment |
•Air temperature: –Device on: 50 to 104×F (10 to 40×C); altitude: 0 to 2000 m (6500 ft) –Device off: -22 to 140×F (-30 to 60×C); maximum altitude: 9144 m (30000 ft) •Humidity –Device on: 20 to 80% (noncondensing at ambient) –Device off: 5 to 90% (noncondensing at ambient) |
1 Acoustical noise emissions |
•Declared sound power, idle: 3.8 bel2 •Declared sound power, operating: 4.9 bel |
3 Heat Output |
•Minimum configuration: 1230 Btu4 (360 watts) •Maximum configuration: 3390 Btu (835 watts) |
1 These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual sound-pressure levels in a given location might exceed the average values stated because of room reflections and other nearby noise sources. The declared sound-power levels indicate an upper limit, below which a large number of computers will operate. 2 In acoustics, the logarithm of the ratio of a quantity to a reference quantity of the same kind is called a level. The base of the logarithm (always ten, unless otherwise specified), the reference quantity, and the kind of level shall be specified. bel is a unit of level when the base of the logarithm is ten, and the quantities concerned are proportional to power. 3 Power consumption and heat output vary depending on the number and type of optional features installed and the power-management optional features in use. 4 BTU = British Thermal Unit. |
Inline Adapter Specifications
Table A-2 describes the inline network adapter technical and general specifications.