Installing the Cisco uBR10012 Router

This chapter describes the procedures for installing the Cisco uBR10012 universal broadband router in an equipment rack. It also describes how to connect interface and power cables, the proper way to power on the system, and installation troubleshooting procedures.

Installation involves doing the following tasks in the following order:


Warning This equipment must be installed and maintained by service personnel as defined by AS/NZS 3260. Incorrectly connecting this equipment to a general-purpose outlet could be hazardous. The telecommunications lines must be disconnected 1) before unplugging the main power connector or 2) while the housing is open, or both. Statement 1043


Installation Methods

For stability and ease of use, the Cisco uBR10012 router chassis should be mounted in an equipment rack. The chassis can be mounted in a 19-inch (standard) equipment rack (either the 4-post equipment rack or the telco-type equipment rack) or in a 23-inch rack.


Note For 23-inch racks, optional mounting brackets must be ordered from third-party vendors.



Caution The Cisco uBR10012 router chassis should always be secured in the equipment rack for normal use and operations.

The rack-mount kit that is shipped with the Cisco uBR10012 router includes four mounting brackets for mounting the chassis in a standard 19-inch wide equipment rack (4-post equipment rack or telco-type). One set of mounting brackets is sufficient to properly secure the router chassis, but an additional set can also be ordered for mounting the chassis from the front and the back.


Note Although installing the chassis in a rack-mount is preferred for permanent installations, you can mount the router in an alternate location, such as on an equipment shelf or on a tabletop for testing or diagnostic purposes.


Preparing the Cisco uBR10012 Router for Rack-Mounting

The Cisco uBR10012 router chassis can be installed in a standard 19-inch equipment rack or telco rack, either front or rear mounted, and either flush or offset from the rack.

This section describes the following guidelines and steps that must be followed before rack-mounting the Cisco uBR10012 router:


Caution Before performing any of the steps in this section, be certain you have read and understood the guidelines given in Chapter2, “Preparing for Installation”

General Rack Installation Guidelines

When planning your rack installation, consider the following guidelines:

  • The Cisco uBR10012 router chassis requires a minimum of 18 rack units (31.5 in. or 80 cm) of vertical rack space. Measure the proposed rack location before mounting the chassis in the rack.
  • Before using a particular rack, check for obstructions (such as a power strip) that could impair rack-mount installation. If a power strip does impair a rack-mount installation, remove the power strip before installing the chassis, and then replace it after the chassis is installed.
  • Allow sufficient clearance around the rack for maintenance. If the rack is mobile, you can push it back near a wall or cabinet for normal operation and pull it out for maintenance (installing or moving line cards, connecting cables, or replacing or upgrading components). Otherwise, allow 19 in. (48.3 cm) of clearance to remove FRUs.
  • Maintain a minimum clearance of 3 in. (7.62 cm) on the front and back of the chassis for the cooling air inlet and exhaust ports, respectively. Avoid placing the chassis in an overly congested rack or directly next to another equipment rack; otherwise, the heated exhaust air from other equipment can enter the inlet air vents and cause an overtemperature condition inside the router.

Caution To prevent chassis overheating, never install a Cisco uBR10012 router in an enclosed rack or room that is not properly ventilated or air conditioned.

  • If also installing the optional AC-input power shelf, allow at last two rack units below the Cisco uBR10012 chassis for the power shelf installation. Install the AC-input power shelf after you have installed the Cisco uBR10012 chassis to avoid the possibility of accidentally crushing the power shelf during the router’s installation.
  • Cisco recommends installing an optional equipment shelf in the rack for the Cisco uBR10012 chassis because it simplifies installation, but this is not required.
  • Always install heavier equipment in the lower half of a rack to maintain a low center of gravity to prevent the rack from falling over. However, if you are also installing an AC-power shelf, leave enough space for the power shelf plus 2 rack units (RUs) underneath the Cisco uBR10012 chassis.
  • Ensure that cables from other equipment already installed in the rack do not impair access to the cards, or require you to disconnect cables unnecessarily to perform equipment maintenance or upgrades.
  • Install rack stabilizers (if available) before you mount the chassis.
  • Provide an adequate chassis ground (earth) connection for your router chassis.

In addition to the preceding guidelines, review the precautions for avoiding excessive temperature conditions in the “Temperature and Humidity Requirements” section.

Removing the Chassis Components Before Installation

The Cisco uBR10012 router is shipped with all ordered components already installed in the chassis. When fully configured, the Cisco uBR10012 chassis weighs approximately 230 lbs (104.3 kg).


Caution You must use a hydraulic lift or forklift to move a fully populated chassis.

If you have to move a fully populated chassis and you do not have a hydraulic lift or forklift available, you must first remove the following components from the chassis:

  • AC or DC power entry modules (PEMs)
  • Fan assembly module
  • Cable interface line cards
  • Network uplink line cards, Slot splitter, and half-height Gigabit Ethernet line cards

In a fully loaded chassis, these components weigh approximately 170 lbs (77.11 kg), removing the components allows the chassis to be moved ssfely using two people. Reinstall the components after the chassis has been moved and installed. Use the following procedures to remove these components.

Before You Begin

  • Make sure that you have an antistatic surface available for the components that you are removing from the chassis.
  • Make sure that you are wearing antistatic protection such as a wrist strap or heel strap and are properly grounded.

Removing the Half-Height Gigabit Ethernet Line Card and the Slot Splitters

This section describes how to properly remove HHGE line cards and the slot splitter from the chassis. This section includes the following tasks:

Removing a Half-Height Gigabit Ethernet Line Card

Use the following procedure to remove the HHGE line card from the slot splitter:


Step 1 Verify that you are properly grounded.

Step 2 Disconnect any network cables connected to the line card port.

Figure 3-1 Captive Screw Locations

 

 

Step 3 Use a screwdriver to loosen the top and bottom captive screws until they disengage and spring away from the face plate (Figure 3-1).

Step 4 Simultaneously pivot both ejector levers away from each other to disengage the line card from the backplane (Figure 3-2).

Step 5 Slide the line card out of the slot splitter and place it on an antistatic surface or in an antistatic bag.

Step 6 If you are not installing a replacement line card, install a blank faceplate in the slot.

Figure 3-2 Opening the Ejector Levers

 


Caution Do not operate the system unless all slots contain a line card or a blank faceplate. Always install a full-slot blank faceplate into an empty slot. Half-height blank faceplates do not have air dams, and the empty slot will rob cooling air from the other slots. A slot splitter with one half-height line card and one blank faceplate is allowed.


Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement 1029



 

Removing the Slot Splitter

Use the following procedure to remove a slot splitter from the chassis:


Step 1 Attach an antistatic wrist strap to your wrist and to the ESD socket on the chassis, or to a bare metal surface on the chassis or frame).

Step 2 Remove any line cards from the splitter, see the “Removing a Half-Height Gigabit Ethernet Line Card” section.

The slot splitter does not have ejector levers to disengage cards from the backplane, so you must remove any line cards before you remove the splitter.

Step 3 Loosen the top and bottom captive screws on the slot splitter (Figure 3-3).

Figure 3-3 Captive Screw Locations

 

 

Step 4 Slide the splitter out of the slot (Figure 3-4).

Step 5 If you are not installing a replacement splitter or a line card, install a full-slot blank faceplate in the slot.

Figure 3-4 Removing the Slot Splitter

 


 

Attaching the Mounting Brackets

The Cisco uBR10012 router is shipped with four mounting brackets that can be attached to either the front or rear of the chassis, depending on your mounting preferences. The brackets can be mounted either flush with the edge of the chassis or set back to allow the chassis to be offset mounted in the rack.

Figure 3-5 shows the mounting brackets shipped with the Cisco uBR10012 chassis for use with a standard 19-inch equipment or telco rack:

Figure 3-5 Mounting Brackets for the Cisco uBR10012 Router

 


Note The four mounting brackets shipped with the Cisco uBR10012 router are for a standard 19-inch equipment rack or telco rack. Optional mounting brackets are orderable separately from third-party vendors to install the chassis in a 23-inch rack.


Use the following procedure to attach the mounting brackets to the chassis.


Step 1 Determine whether you will be mounting the chassis with the front or rear facing forwards.

Step 2 Determine whether you will flush-mount or offset-mount the chassis. Typically, flush-mounting is used for most equipment racks except for telco racks that require offset-mounting. If either style can be used, choose the one that is most convenient for your site.

Step 3 Attach two mounting brackets to each side of the chassis in the appropriate locations. The large mounting bracket is attached to the top of the chassis, and the smaller bracket is attached to the bottom of the chassis.

Attach the brackets as shown in the following figures, using the screws that are supplied with the brackets:

  • Figure 3-6 shows how to attach the brackets to flush-mount the chassis with the front forwards.
  • Figure 3-7 shows how to attach the brackets to flush-mount the chassis with the rear forwards.
  • Figure 3-8 shows how to attach the brackets to offset-mount the chassis with the front forwards.

Figure 3-6 Bracket Location for Flush Front-Mounting the Chassis

 

Figure 3-7 Bracket Location for Flush Rear-Mounting the Chassis

 

Figure 3-8 Bracket Location for Offset Front-Mounting the Chassis

 


Note You must use three screws to install each large bracket and two screws to install each small bracket.



 

To install the optional cable management brackets, proceed to the next section. Otherwise, proceed to the “Mounting the Chassis in the Rack” section for instructions on mounting the Cisco uBR10012 chassis in the equipment or telco rack.

Installing the Cable Management Brackets (Optional)

The Cisco uBR10012 router is shipped with two cable management brackets that can be installed on the rear of the router’s chassis to route the cables connected to the cable interface line cards.

For installing first-generation cable management brackets see “Installing First-Generation Cable Management Brackets” section and for installing second-generation cable management bracket see “Installing the Second-Generation Cable Management Bracket” section.

Installing First-Generation Cable Management Brackets

Figure 3-9 shows the rear of Cisco uBR10012 chassis with the two first-generation cable management brackets installed.

Figure 3-9 Installing the Optional First-Generation Cable Management Brackets

 

 

Use the following procedure to install the optional first-generation cable management brackets on the rear of the Cisco uBR10012 chassis:


Step 1 Position the first mounting bracket immediately above the cable interface line card installation slots. Make sure that the portion of the bracket with the slots is above the mounting holes, so that the bracket will not interfere with the insertion and removal of the line cards. See Figure 3-9.

Step 2 Align the mounting holes on the far left and far right on the bracket first, so that the center mounting hole will be aligned properly.

Step 3 Use the three screws that are provided in the accessory kit to attach the bracket to the chassis.

Step 4 Attach the bottom cable management bracket in a similar manner, making sure that the slot edge of the bracket is pointing down. See Figure 3-9.


Note Make sure that the slot edge on the bracket is pointed downward, otherwise the bracket interferes with the insertion and removal of the cable interface line cards.


Step 5 Insert cable ties through the slots on the top and bottom of the brackets and use the cable ties as needed to secure the cables for the line card interfaces along the top and bottom of the chassis.


 

Installing the Second-Generation Cable Management Bracket


Note The Cisco uBR10012 chassis now ships with only one second-generation cable management bracket.


Attaching Cable Management Bracket on the Rear Flush-Mounted Chassis

To install the optional second-generation cable management bracket on the rear-side (line-card side) of the flush-mounted Cisco uBR10012 chassis:


Step 1 Attach the cable management bracket rack-rail mounting left adaptor to the left side of the cable management bracket, using two of the four M5 attachment thumb screws supplied with the bracket. See Figure 3-10.

Step 2 Attach the cable management bracket rack-rail mounting right adaptor to the right side of the cable management bracket, using the remaining two M5 attachment thumb screws supplied with the bracket. See Figure 3-10.

 

Figure 3-10 shows the second-generation cable management bracket and the cable management rack-rail mounting adaptors used when the Cisco uBR10012 chassis is rear flush-mounted.

Figure 3-10 Second-Generation Cable Management Bracket and Rack-Rail Mounting Adaptors

 

1

Second-generation cable management bracket rack-rail mounting right adaptor

3

Second-generation cable management bracket

2

M5 attachment thumb screws

4

Second-generation cable management bracket rack-rail mounting left adaptor

Step 3 Attach the cable management assembly to the rack-rails, using screws. See Figure 3-11.

Figure 3-11 shows the rear flush-mounted Cisco uBR10012 chassis in rack-rails with a second-generation cable management bracket installed above the line card slots.

Figure 3-11 Second-Generation Cable Management Bracket on the Rear Flush-Mounted Chassis

 

 

1

Second-generation cable management bracket rack-rail mounting adaptors

4

M5 attachment thumb screws

2

Cisco uBR10012 chassis

5

Second-generation cable management bracket

3

Rack pole

6

Line card slots


 

Attaching Cable Management Bracket on the Rear Offset-Mounted Chassis

To install the optional second-generation cable management bracket on the rear-side (line-card side) of the offset-mounted Cisco uBR10012 chassis:


Step 1 Align the holes of the cable management bracket with holes meant for the mounting bracket on the left and right side of the chassis. See Figure 3-12.

Step 2 Attach the cable management bracket to the chassis, using the four M5 attachment thumb screws that are supplied with the bracket. See Figure 3-12.

 

Figure 3-12 shows the rear offset-mounted Cisco uBR10012 chassis with a second-generation cable management bracket installed above the line card slot.

Figure 3-12 Installing the Second-Generation Cable Management Bracket on the Rear Offset-Mounted Chassis

 

 

1

Cisco uBR10012 chassis

3

Cable management bracket

2

M5 attachment thumb screws

4

Line card slots


 

Mounting the Chassis in the Rack

With the fan assembly, PEMs, and line cards removed from the chassis and the mounting brackets installed on the chassis, the Cisco uBR10012 chassis is ready for installation in a 19-inch equipment rack or telco rack. Use the following procedure to install the chassis.

 


Warning



To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:

  • This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
  • When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
  • If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006


 


Tip (Optional) Install a shelf in the rack to support the Cisco uBR10012 router chassis. This simplifies installation and provides additional support for the chassis. If you are installing an equipment shelf, it must be able to support the weight of a fully loaded chassis which is approximately 230 lbs (104.3 kg).



Tip If you are installing the chassis in an equipment rack, it is helpful to have a third person available to maneuver the chassis into position and attach the brackets to the rack.


Recommended Tools and Supplies

Table 3-1 lists the tools, equipment, and supplies necessary to connect the system ground to the chassis.

 

Table 3-1 Tools and Supplies

Quantity
Description
Comments

1

Number 2 Phillips screwdriver

1

A 3/16-inch flat-blade screwdriver s

1

A 1/4-inch flat-blade screwdriver

12

Mounting bracket screws

Included in accessory kit

1

ESD-preventive wrist strap

Tape measure (optional)

Level (optional)

Installing the Cisco uBR10012 Chassis in the Rack

When you are installing the chassis in a rack, please be aware of the following issues.

  • AC power shelf installation precautions
  • Loaded and unloaded chassis weight

Caution If you are using the optional AC-input power shelf, do not install the shelf until after you have installed the Cisco uBR10012 chassis to avoid the possibility of crushing the shelf during the router’s installation.

For more information about installing the power shelf, see 2400W AC-Input Power Shelf for the Cisco uBR10012 Universal at the following URL:
http://www.cisco.com/en/US/docs/cable/cmts/ubr10012/installation/field_replaceable_units/ub10acsh.html


Caution A fully populated chassis weighs approximately 230 lbs (104.3 kg) and should be lifted only with a forklift or hydraulic lift. A depopulated chassis weighs approximately 55 lbs(24.95 kg) and should be lifted by two people. When handling the chassis, always follow proper lifting practices, as outlined in the “Chassis-Lifting Guidelines” section


Warning Two people are required to lift the chassis. Grasp the chassis underneath the lower edge and lift with both hands. To prevent injury, keep your back straight and lift with your legs, not your back. Statement 210



Warning At least three people are required to mount the shelf in the equipment rack: two people are needed to hold the shelf in place while a third person tightens the mounting screws. Statement 336



Step 1 Verify that you have removed the fan assembly module, DC PEMs, cable interface line cards, and network uplink line cards before attempting to move the chassis (see “Removing the Chassis Components Before Installation” section).


Caution Do not attempt to lift even a depopulated chassis by yourself. Have at least two people to lift the chassis. Three people might be needed to position the chassis into a rack, depending on whether you are using an equipment shelf and on how high you are mounting it.

If you have to lift the chassis to a higher location, have a third person present who can lift the middle of the chassis as the other two people lift it straight up.

Step 2 With each person standing on a side of the chassis, bend straight down at the knees, and grab one of the handles on the side of the chassis.

Step 3 Carefully lift the chassis straight up and walk with slow, deliberate steps to your destination.


Caution To prevent injury, keep your back straight and lift with your legs, not your back.

Step 4 When you reach your destination, bend at the knees to lower the chassis to the ground.

Step 5 Lift the chassis up to the height that it will be positioned in the rack.

Step 6 Maneuver the chassis into position in the rack.

Step 7 Align the mounting bracket holes with the rack post holes (Figure 3-13) and attach the chassis to the rack with the appropriate-sized screws (performed by the third person unless the chassis is resting on a shelf).

Step 8 Go to the Connecting the Chassis to Ground section to continue the installation.


Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024



Note Figure 3-13 shows the chassis flush-mounted at the rear. The procedure is identical for the other mounting methods. This figure also shows two sets of mounting brackets being used, one set at the front and one set at the rear of the chassis. Only one set of brackets is necessary to support the chassis.


Figure 3-13 Installing the Chassis in a Rack using the Rear Mounting Brackets

 

 

1

Rear mounting brackets

 


 

Attaching Ferrite Beads on the Cables

Ferrite beads can be clamped on where the beads are attached without wrapping the wires. Two ferrite beads (part number 36-0219-01) are included in the Cisco uBR10012 router accessory kit, and one ferrite bead is shipped with the spare of AC and DC power entry modules.

Attaching Ferrite Beads on Grounding and Alarm Cables

For Class B emission compliance requirements, one ferrite bead must be installed on the alarm port and chassis ground wire exiting the chassis. This is applicable for UBR10-PWR-AC, UBR10-PWR-AC-PLUS=, and UBR10-PWR-DC-PLUS= PEM modules. The ferrite bead should be installed (within 3 inches) close to the notch where the cables exit the chassis.

Figure 3-14 Ferrite Beads on Ground Cable and Alarm Cable

 

1

Alarm cable

3

Ferrite bead attached to both the ground and alarm cable

2

Ground cable

 

Attaching Ferrite Beads on DC Power Cables

For Class B emission compliance requirements, two ferrite beads must be installed on the DC-input power cables. This is applicable for UBR10-PWR-DC= PEMs. These ferrite beads should be installed (within 6 inches) close to the DC-input power connector (DC-input terminal connector).

Figure 3-15 shows the ferrite beads attached to the DC-input power cables connected to the DC-input terminal connector located beneath the UBR10-PWR-DC= module on the midplane of the chassis.

Figure 3-15 Ferrite Beads Attached on DC-input Power Cables

 

1

Ferrite beads attached to DC-input power cables

3

DC power cables

2

DC-input terminal connector on midplane of the chassis

 

Attaching Ferrite Beads on the Lineage Power Shelf

An additional set of ferrite beads are required if you are using the external Lineage power shelf to supply power to the Cisco uBR10012 router. These ferrite beads must be installed on the DC power cables that are provided in the Lineage accessory kit to meet the Class A compliance requirements. Table 3-2 lists the ferrite beads that should be installed on the different DC power cables.

 

Table 3-2 Ferrite Beads, DC Power Cables, and DC PEM Modules

Ferrite Beads (Type / Part Number)
DC Power Cable
DC PEM Module (Part Number)

Steward 28A5776-0A2

4 DC power cables

UBR-PWR-DC=

Steward 28A5131-0A2

2 DC “Y” power cables

UBR-PWR-DC-PLUS=

The ferrite beads should be installed within 6 inches of the DC terminal blocks on the Lineage power shelf. (See Figure 3-16 .)


Note The ferrite beads must be installed on both sides of the DC power cables (DC-input and DC-output) when Lineage power shelf is connected to the DC PEM modules (UBR-PWR-DC=) on the Cisco uBR10012 router.


Figure 3-16 Ferrite Beads on the Lineage Power Shelf

 

1

DC power cables connected on the Lineage power shelf

3

Alarm cable connected to the J1 connector with built-in ferrite bead

2

Ferrite beads attached on the DC power cables

 

Connecting the Chassis to Ground

Connecting the Cisco uBR10012 router chassis to earth ground is required for all DC powered installations. Have the recommended tools and supplies available before you begin this procedure (see Table 3-3).


Warning The importance of proper grounding cannot be overemphasized. It will minimize the potential for damage to your system and maximize safety at the system site. We recommend you consult a licensed electrician or your local electric utility company if you have any questions. Statement 269



Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046


Recommended Tools and Supplies

Table 3-3 lists the tools, equipment, and supplies necessary to connect the system ground to the chassis.

 

Table 3-3 Tools and Supplies

Quantity
Description
Comments

1

Number 2 Phillips screwdriver

1

Wire stripping tool

1

Crimping tool

Must fit diameter of grounding lugs.

1

2-hole grounding lug

Included in the accessory kit

1

Grounding wire

6 AWG (16 mm2), customer provided.

2

M5 Pan Head screws with captive, lock washers

Included in accessory kit.

 

Antistatic mat and ESD-wrist strap

Attaching the Grounding Cable

The following procedure describes how to attach:

  • The grounding lug to the grounding cable.
  • The grounding cable to the chassis.
  • The grounding cable to the earth grounding point.

Warning Use copper conductors only. Statement 1025



Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position. Statement 7



Step 1 Verify that there is no power going to the Cisco uBR10012 chassis and the PEMs are not installed.

Step 2 Strip about 3/4 inch (2 cm) of the covering from the end of the grounding wire).

Step 3 Insert the stripped end of the grounding wire into the open end of the grounding lug and crimp the grounding lug securely to the wire.

Step 4 Using the two M5 screws provided in the accessory kit, fasten the grounding lug firmly to the bottom of the chassis. Fasten the lug to the chassis. See the location marked “Grounding points” in Figure 3-18).

Step 5 Attach the other end of the ground cable to a suitable grounding location in accordance with local practice at your site.

Step 6 Proceed to the next section, Connecting DC Power to the Cisco uBR10012 Router.

Figure 3-17 Attaching Grounding Wire to the Grounding Lug

 

Figure 3-18 Location of the Ground Lug Connectors

 


 

Connecting the External AC-input Power Shelf to the Cisco uBR10012 Router

The following sections describe how to connect the Lineage AC-DC power shelf to the Cisco uBR10012 router:

For information on cabling, and installation of the external 2400 W AC-input power shelf, see the 2400 W AC-input Power Shelf Installation Guide .

Cabling the Lineage AC-DC Power Shelf

Prerequisites

  • To meet compliance standards, it is recommended that you use the AC-input cables, DC power cables, and alarm monitor cable that are provided in the Lineage AC-DC power shelf accessory kit.
  • To meet Class A compliance standards, the ferrite beads provided in the Lineage AC-DC power shelf accessory kit must be installed on the DC power cables. For more details, see Attaching Ferrite Beads on the Lineage Power Shelf.

Required Tools and Equipment

  • Lineage AC-DC power shelf
  • Alarm monitor cable, provided in Lineage accessory kit
  • DC power cables, provided in Lineage accessory kit
  • AC-input power cables, provided in Lineage accessory kit
  • Ferrite beads, provided in Lineage accessory kit
  • 10 mm hex socket driver

Steps

To attach the cables to the Lineage AC-DC power shelf:


Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. Statement 1003



Caution Do not connect the AC power cables to the facility power source until the DC power cables and the alarm monitor cables are connected to the power shelf, and to the Cisco uBR10012 router.


Step 1 Open the safety cover from above the DC terminal blocks by rotating the safety cover up and off of the DC terminal blocks of the power shelves.

Step 2 Loosen and remove the M6 nuts.

Step 3 Install the DC power cables to both the DC power terminal blocks on the power shelf using the removed M6 nuts, and close the safety cover.


Note If you are connecting two Lineage power shelves to the Cisco uBR10012 router, then connect the DC “Y” power cables only to the left DC terminals block on the two power shelves.


Step 4 Attach the ferrite beads to the DC power cables pairs exiting the power shelf within 6 inches from the DC terminal blocks on the power shelf. See “Attaching Ferrite Beads on the Lineage Power Shelf” section.

Step 5 Connect the alarm monitor cable to the power shelf, see Connecting the Alarm Monitor Cable

Step 6 Proceed to connecting the Lineage power shelf to the Cisco uBR10012 router.

Step 7 Connect the un-energized AC power cables to the power shelf.


Caution The AC power cables must not be connected to the wall socket until, all the DC power cables and alarm monitor cables are connected between the power shelf and the Cisco uBR10012 router.

Step 8 Connect the AC power cables to the facility wall socket to energize the power shelf.


Caution Exercise caution while connecting the AC power cables to the an energized wall socket as the power shelf will start supplying power to the Cisco uBR10012 router.


 

Connecting the Lineage AC-DC Power Shelf to the Cisco uBR10012 Router

The Lineage power shelves are used with the DC PEM modules on the Cisco uBR10012 router. Two DC PEM modules are supported on the Cisco uBR10012 router:

  • DC PEM module (UBR10-PWR-DC=)
  • DC PEM module (UBR10-PWR-DC-PLUS=)

The following sections explain how to connect the Lineage power shelves to the Cisco uBR10012 router:

Connecting the Lineage Power Shelf to the UBR-PWR-DC= Module

Prerequisites

Required Tools and Equipment

  • 2400 W DC PEM module (UBR-PWR-DC=)
  • One Lineage AC-DC power shelf
  • Four DC power cables, provided in Lineage accessory kit
  • One alarm monitor cable, provided in Lineage accessory kit
  • Ferrite beads (part number 36-0219-01), provided in Cisco uBR10012 router accessory kit
  • Ferrite beads, provided in Lineage accessory kit
  • Flat-head screwdriver

Steps

To connect the power shelf to the UBR-PWR-DC= module:


Step 1 Cable the Lineage AC-DC power shelf, see “Cabling the Lineage AC-DC Power Shelf” section.


Caution Do not connect the AC power cables to the standard wall socket.

Step 2 Connect the alarm monitor cable to the Cisco uBR10012 router, see “Connecting the Alarm Monitor Cable” section.

Step 3 Attach the pair of the ferrite beads to the ends of DC power cables that connect to the Cisco uBR10012 router. See “Attaching Ferrite Beads on DC Power Cables” section.

Step 4 Connect into the DC power cables into DC-input terminal connectors at the backplane of the Cisco uBR10012 router. For information connecting the DC power cables to the Cisco uBR10012 router, see DC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .


Caution The DC power cables have joggles at the ends of the cables. While connecting these joggled ends to the Cisco uBR10012 router, ensure that the ends face away from each other. (See Figure 3-19.)

Figure 3-19 shows the Lineage power shelf connected to the UBR-PWR-DC= PEM module on Cisco uBR10012 router.

Figure 3-19 Lineage AC-DC Power Shelf Connected to UBR-PWR-DC= PEM Module

 

 

1

DC power cables connected from the Lineage power shelf to the backplane of the router

4

Joggled ends of the DC-input power cables connected DC-input terminal blocks at the backplane of the router

2

Cisco uBR10012 router

5

Alarm monitor cable

3

Lineage AC-DC power shelf

 

Step 5 Connect the AC power cables to a standard wall socket (facility power source) to provide power to the Cisco uBR10012 router.


 

Connecting the Lineage Power Shelf to the UBR-PWR-DC-PLUS= Module

Prerequisites

  • Two Lineage AC-DC power shelves are required to supply power to the UBR-PWR-DC-PLUS= modules to power on the Cisco uBR10012 router.
  • To meet Class A compliance standards, the ferrite beads must be installed on the DC “Y” power cables exiting the Lineage power shelf within 6 inches from the DC terminal blocks. For more details, see Attaching Ferrite Beads on the Lineage Power Shelf.

Required Tools and Equipment

  • 3300 W DC PEM module (UBR-PWR-DC-PLUS=)
  • Two Lineage AC-DC power shelves
  • Two DC “Y” power cables (Amphenol), provided in Lineage accessory kit
  • Two alarm monitor cables, provided in Lineage accessory kit
  • Ferrite beads, provided in Lineage accessory kit
  • Flat-screw driver
  • 10 mm hex socket driver

Note We recommend that you use the DC “Y” power cables provided in the Lineage accessory kit. If you are using a 4 AWG cable, use a high-flex high strand count power cable for optimal routing of the cables under the front cover of the Cisco uBR10012 router. The 2 AWG wire is not supported on the UBR-DC-PWR-PLUS= DC PEM module.


Steps

To connect the power shelf to the UBR-PWR-DC-PLUS= DC PEM module:


Caution Do not have the AC power cables attached from the Lineage power shelves to the facility power sources, while attempting to connect the DC power cables from the power shelves to the UBR-PWR-DC-PLUS= modules of the Cisco uBR10012 router.


Step 1 Follow the steps to connect cables to the two Lineage power shelves, see Figure 3-21:

a. Open the safety cover from above the DC terminal blocks by rotating the safety cover up and off of the DC terminal blocks of the shelves

b. Loosen and remove the M6 nuts.

c. Attach the lugged ends of the DC “Y” power cables to left DC power terminal blocks of the two power shelves. Secure the cables with the removed M6 nuts using a 10 mm hex socket driver with an installation torque of 45-in lbs. (See Figure 3-20.)

d. Close the safety cover on the DC terminal blocks.

e. Attach the ferrite beads (Steward 28A5131-0A2) to the DC “Y” power cables pairs (both -48 V and RTN cables) exiting the Lineage power shelves within 6 inches from the DC terminal blocks. See “Attaching Ferrite Beads on the Lineage Power Shelf” section.

Figure 3-20 DC Y Power Cable with Lugged Ends

 

 

1

Lugged end of DC Y power cable that connects to Lineage power shelves

3

Lugged end of DC Y power cable that connects to the DC terminal blocks on the UBR-PWR-DC-PLUS= modules.

2

Lugged end of DC Y power cable that connects to the DC terminal blocks on the UBR-PWR-DC-PLUS= modules.

 


Caution Only the left DC power terminals of the two Lineage shelves are used with UBR-PWR-DC-PLUS= modules on the Cisco uBR10012 router. Ensure that the right DC power terminals on the Lineage shelves are covered with the provided plastic covers.

f. Attach the alarm monitor cables to the two Lineage power shelves, see “Connecting the Alarm Monitor Cable” section .


Note Only one cable of alarm monitor cable is connected to each Lineage power shelf. The other end of the cable is unused. (See Figure 3-21.)


g. Connect the un-energized AC power cables to the power shelf.


Caution Do not connect the AC power cables to the facility power sources until the DC power cables and the alarm monitor cables are connected to the power shelf, and to the Cisco uBR10012 router.

Figure 3-21 Cabling Two Lineage Power Shelves with DC Y Power Cables and Alarm Cables

 

 

1

Left DC power terminal blocks

8

Cisco uBR10012 router

2

Alarm monitor cable connected to the J1 connector that connects to external alarm input connector on DC PEM 1

9

Ferrite beads installed on DC power cables

3

Unused end of the alarm monitor cables

10

Red Y cables that connects to –48 V terminals on DC PEM 0

4

Alarm monitor cable connected to the J1 connector that connects to external alarm input connector on DC PEM 0

11

Black Y cables that connects to RTN terminals on DC PEM 0

5

Built-in ferrite beads on alarm cable

12

Red Y cables that connects to –48 V terminals on DC PEM 1

6

Unused right DC power terminal blocks

13

Black Y cables that connects to RTN terminals on DC PEM 1

7

Lineage power shelves

 

Step 2 Connect the DC “Y” power cables to the DC-input terminal blocks on the UBR-PWR-DC-PLUS= modules on the Cisco uBR10012 router. For information on connecting the cables, see 3300 W DC PEM Module for Cisco UBR10012 Broadband Router Chassis .

Step 3 Connect the alarm monitor cables to the external alarm input connectors on the UBR-PWR-DC-PLUS= modules.

Step 4 Route the DC “Y” power cables through the front of the chassis through the three power cord clips.

Figure 3-22 shows the DC “Y” power cables—Black cables are connected to RTN terminals and the red cables are connected to –48 V terminals on the DC PEMs. The alarm monitor cables (marked in grey) are connected to the alarm input connectors on each PEM module.

Figure 3-22 DC Y Power Cables and Alarm Cables Connected from Lineage Power Shelves to UBR-PWR-DC-PLUS= Modules

 

 

1

Alarm monitor cables connected to J1 connectors, which in turn are connected to external alarm input connectors on DC PEMs

5

Red Y cables connected to –48 V terminals on DC PEM 0

2

Black Y cables connected to RTN terminals on DC PEM 0

6

Red Y cables connected to –48 V terminals on DC PEM 1

3

DC PEM 0

7

Black Y cables connected to RTN terminals on DC PEM 1

4

DC PEM 1

8

Unused end of the alarm monitor cables


Note Ensure that you lift the handles and route the cables underneath the handles and through the power cord clips of the PEM modules so that the front cover fits on the Cisco uBR10012 chassis.


Step 5 Connect the AC power cables to a standard wall socket (facility power source) to provide power to the Cisco uBR10012 router.

Connecting the Alarm Monitor Cable

The alarm monitor cable when connected to the Cisco uBR10012 router provides information on whether a power module in the power shelf is missing, reporting a fault, experiencing an over-temperature condition, or is not receiving AC-input power. This alarm monitor cable is connected from the power shelf to the external alarm input connectors on the DC PEM faceplates of the Cisco uBR10012 router. (See Figure 3-23 .)

Figure 3-23 Alarm Monitor Cable

 

 

Prerequisites

  • Install the Lineage power shelf in the rack in a way that the power connections reside facing inside the rack when viewed from the front.
  • Use the alarm monitor cables provided in the Lineage accessory kit.

Required Tools and Equipment

  • Alarm monitor cable, provided in Lineage accessory kit
  • Lineage power shelf

Steps

To connect the alarm monitor cable from the Lineage power shelf to the Cisco uBR10012 router:

1. Connect the PIN end of the alarm monitor cable to the JI housing on the power shelf. (See Figure 3-24 .)

Figure 3-24 Alarm Monitor Cable with PIN and RJ-45 connectors

 

 

1

PIN end of Alarm monitor cable that connects to the Lineage power shelves.

3

RJ-45 connector end that connects to the alarm input connector on the DC PEM modules.

2

RJ-45 connector end that connects to the alarm input connector on the DC PEM modules.

 

2. Connect the two RJ-45 connector ends of the alarm monitor cable into the alarm input connectors on the DC PEM modules of the Cisco uBR10012 router. (See Figure 3-25.)


Note Two alarm monitor cables are required when connecting two Lineage power shelves with the UBR-PWR-DC-PLUS= PEM modules. Use one RJ-45 connector end of each alarm monitor cable to connect to the alarm input connectors on each UBR-PWR-DC-PLUS= PEM modules. (See Figure 3-21).


Figure 3-25 Alarm Monitor Cable Connected From the Lineage AC-DC Power Shelf to UBR-PWR-DC= Module

 

 

1

Alarm input connector on the UBR-PWR-DC= module

2

Alarm monitor cable

Disconnecting Cables from the Lineage AC-DC Power Shelf and the Cisco uBR10012 Router

To disconnect cables from the Lineage AC-DC power shelf and the Cisco uBR10012 router:


Caution Ensure that the power is turned off on the power shelf by disconnecting the power supply at the facility before proceeding to disconnect the other cables.

1. Power off the power shelf by disconnecting the power supply at the facility. Wait a few minutes before disconnecting the power cables so that they discharge.

1. Disconnect the AC cables from the standard wall socket. Disconnect the AC power cables from each of the AC-input power supply sources on the power shelf.

2. Disconnect the alarm monitor cable from the J1 housing on the power shelf, and from the alarm input connectors on the DC PEM modules of the Cisco uBR10012 router.

3. Disconnect the DC power cables on each side of the DC power sources, on the power shelf.

4. Disconnect the other ends of the DC power cable from the DC power terminal blocks of the Cisco uBR10012 router.

Connecting DC Power to the Cisco uBR10012 Router

This section describes how to connect the Cisco uBR10012 router to the two –48/–60 VDC power sources that provide its operating power. The DC power sources can either be already present at the site, or they can be provided by the external AC-input power shelves. If using the external 2400 W AC-input power shelf, be certain you have already installed it, as described in the 2400 W AC-Input Power Shelf Installation Guide .


Note For full power redundancy, each terminal block on the external power shelf must be connected to a separate power source. If using the optional 2400 W AC-input power shelf, full power redundancy also requires that each of the AC power supplies in the shelf be connected to AC power sources that are on separate circuit breakers.



Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. Statement 91



Warning Connect the unit only to DC power source that complies with the safety extra-low voltage (SELV) requirements in IEC 60950 based safety standards. Statement 1033



Warning Secure all power cabling when installing this unit to avoid disturbing field-wiring connections. Statement 38



Warning Care must be given to connecting units to the supply circuit so that wiring is not overloaded.
Statement 51



Warning This product requires short-circuit (overcurrent) protection, to be provided as part of the building installation. Install only in accordance with national and local wiring regulations. Statement 1045



Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position. Statement 7



Caution Be sure that you have connected the chassis to earth ground as described in the previous section before beginning this procedure.

Recommended Tools and Supplies

Table 3-4 lists the tools and supplies that you need to connect the Cisco uBR10012 router to DC power sources.

 

Table 3-4 Tools and Supplies for Connecting DC Power

Quantity
Description
Comments

1

Flat-blade screwdriver

1

Number 2 Phillips Screwdriver

1

Wire stripping tool

1

10 mm hex socket driver

4 (length varies)

6 AWG (16 mm2) wire cables

Cables must reach from the Cisco uBR10012 router to the DC power source. The end of the cable intended to be connected to the chassis needs to have insulation stripped back not more than 5/16-in. (8 mm).

Note The UBR10-PWR-DC-PLUS= module accepts a maximum of 6 AWG wire or 4 AWG high-flex wire for the DC-input cables. If you are using the 4 AWG wire, use a high-flex high strand count power cable for optimal routing of the cables under the front cover. The 2 AWG wire is not supported on the UBR10-PWR-DC-PLUS= module.

4

0.625-inch dual-hole lugs

Prepare the DC-input cables by attaching 0.625-inch center to center dual-hole lugs.

2

Tie wraps

The tie wraps bind the cables together and also bind the cables to the side of the chassis.

 

Antistatic mat and ESD-wrist strap

If necessary

Connecting the Cisco uBR10012 Chassis to a DC Power Source

The DC power sources can be present at the site, or they can be provided by an external AC-input power shelf. If you are using the 2400 W AC-input power shelf, ensure that you have already installed it, as described in the 2400 W AC-input Power Shelf Installation Guide .

For information on connecting the DC-input power cables for the UBR10-PWR-DC= module to the Cisco uBR10012 router, see DC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .

For information on connecting the DC-input power cables for the UBR10-PWR-DC-PLUS= DC PEM module to the Cisco uBR10012 router, see 3300 W DC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .

Connecting Alarm Indicators

The Cisco uBR10012 router provides relay contacts for optional (customer-supplied) audible or visual alarm indicators. Relay contacts are provided for three levels of severity:

  • Minor—This is an informational alarm and does not affect the system operation.
  • Major—A condition that affects system operation and should be investigated as soon as possible.
  • Critical—A condition that affects system operation and requires immediate attention.

Recommended Tools and Supplies

Table 3-5 lists the tools and supplies that you need to connect the alarm indicators.

 

Table 3-5 Tools and Supplies for Connecting Alarm Indicators

Quantity
Description
Comments

1

Flat-blade screwdriver

1

Wire stripping tool

6

14 AWG wire cables

 

ESD-preventive wrist strap

If necessary

Use the following procedure to connect an alarm indicator to the chassis:


Step 1 Obtain sufficient wire for the desired connections. You will need two wires for each set of relays, or six separate wires to connect all three relay contacts. Use the gauge of wire required by the audible or visual alarm indicator equipment you are using (14 AWG maximum gauge).


Warning Use copper conductors only. Statement 1025



Caution The alarm contacts on the Cisco uBR10012 router are only relays and do not provide any power from the unit. These relays are rated for 60 VDC, 1 A maximum—ensure that the connected alarm equipment does not exceed these voltage and current ratings.

Step 2 Strip approximately 0.31 in. (8 mm) of insulation off the ends of the alarm indicator wire (see Figure 3-26).

Figure 3-26 Stripping Insulation

 

Step 3 Connect one set of alarm indicator wires to the alarm terminal block as follows (see Figure 3-27):

a. Connect one lead to the common (COM) terminal.

b. If you are wiring the router in with other equipment for the alarm indicators, wire the other lead to the normally closed (NC) terminal.

c. If you are wiring the router in parallel with other equipment for the alarm indicators, wire the other lead to the normally open (NO) terminal.


Caution Figure 3-27 shows the wiring configuration for NO alarm relays. The wiring configuration for NC alarm relays is similar but uses the NC contacts.

Step 4 Repeat step 3 for the remaining alarm indicators.

Step 5 Secure the power cabling to the chassis by feeding a tie wrap through the square slot on the left front side of the chassis (next to the alarm indicator terminal block) and binding the wires.

Figure 3-27 Alarm Terminal Block Connections

 

Step 6 Go to the next section, Connecting the Console Port and Auxiliary Port, to continue the installation.


 

Installing the Modules

To install the modules in the Cisco uBR10012 router:


Step 1 Remove the front cover by pulling the cover towards you and carefully set it aside.

    • Fan assembly module—Align the module with the slot in the chassis. Push the fan module back firmly into the chassis, making sure that the module securely connects to the backplane. Tighten the captive screws on each side of the fan assembly module.

Note To tighten the captive screws on the fan assembly modules, the installation torque used should be 8 in-lbs.



Caution The total service window for removal and replacement of the fan tray is 3 minutes before possible system shutdown. Ensure that you complete the replacement procedure within this time limit.

For more information on installing the fan assembly module, see Cisco uBR10012 Universal Broadband Router Fan Assembly Module .

    • DC power entry module—Position the DC PEM in the power bay and slide it all the way in and ensure it makes a secure connection with the backplane.

For information on installing the UBR10-PWR-DC= module, see DC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .

For information on installing the UBR10-PWR-DC-PLUS= module, see 3300 W DC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .

    • AC power entry module—Position the AC PEM in the power bay and slide it all the way in and ensure it makes a secure connection with the backplane.

For information on installing the UBR10-PWR-AC= module, see AC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .

For information on installing the UBR10-PWR-AC-PLUS= module, see 3300 W AC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .


 

Installing the Line Cards and Uplink Cards

After the chassis has been firmly attached to the rack, reinstall the cards in the chassis (also see Removing and Replacing a Cable Interface Line Card for details).


Caution The Cisco uBR10012 router supports only the Cisco uBR10-LCP2-MC28C cable interface line card or Cisco uBR10-LCP2-MC16x cable interface line card bundles. Do not install the Cisco uBR10-LCP2 adapter card in the Cisco uBR10012 chassis without either the Cisco MC16x or the Cisco MC28C installed in the adapter card.

Also, do not attempt to remove the Cisco MC28C card or the Cisco MC16x card from their carriers (adapter cards) while the they are installed in the chassis. See the “Removing and Replacing a Cable Interface Line Card” section for information on this procedure.


Step 1 Grasp the faceplate of the first line card with one hand and place your other hand under the card carrier (to support the weight of the card) and position the card in front of the appropriate card cage slot.

Step 2 Carefully align the upper and lower edges of the line card with the upper and lower guides in the chassis, and slide the cable interface line card into the slot until you can feel it begin to seat in the backplane connectors (Figure 3-28).

Step 3 Simultaneously pivot both ejector levers toward each other (until they are parallel to the faceplate) to firmly seat the card in the backplane (Figure 3-29).

Step 4 Finger tighten the captive screws to secure the card in the chassis.


Caution Do not tighten the captive screws until after you insert all the additional cards. Tightening the captive screws before all the line cards are installed, can cause the installation slot for the last line card to be restricted and make it difficult to install the card.

Step 5 Repeat Step 1through Step 4 for each cable interface line card and network uplink card.

Step 6 After all the line cards and network uplink cards are inserted, tighten the captive screws. (Torque 5 to 7 in-lbs.)


Tip Tighten line card 1, then tighten line card 8, tighten line card 2 then line card 7. Alternate back and forth between the line cards until all of them are secure in the chassis.



Tip These screws prevent accidental removal and provide proper grounding for electromagnetic interference (EMI) shielding.


Figure 3-28 Inserting the Cable Interface Line Card

 

Figure 3-29 Closing the Ejector Levers

 


 

Installing the Slot Splitter and Half-Height Gigabit Ethernet Line Card

This section describes how to install the line card in the Cisco uBR10012 router. This section includes the following tasks:


Caution You must use slot 3 or slot 4 when installing the slot splitter and HHGE line card in the Cisco uBR10012 router, using slot 1 or slot 2 will cause the router to shut down those slots.


Caution Do not install two half-height blank faceplates into the same slot in the slot splitter. Instead, install a full-slot blank faceplate into the slot. The half-height blank faceplates do not have air dams, and the empty slot will rob cooling air from the other slots. A slot splitter with one half-height line card and one blank faceplate is allowed.


Caution Do not install a line card into the slot splitter before installing the splitter into the chassis. The slot splitter does not have ejector levers that allow you to seat the line card in the backplane.

Installing the Slot Splitter

You must install the half-height line card into a slot that contains a slot splitter, which can hold two half-height line cards. If both slots of the slot splitter are not used, then you must install a blank faceplate in the empty slot.

Follow these steps to install a slot splitter into slot 3 or slot 4 (Figure 3-30) of the Cisco uBR10012 chassis.


Step 1 Attach an antistatic wrist strap to your wrist and to an ESD socket on the chassis, or to a bare metal surface on the chassis or frame.

Step 2 Grasp the front of the slot splitter with one hand and place your other hand under the splitter. Position the splitter in front of the card cage slot.

Step 3 Carefully align the upper and lower edges of the slot splitter with the upper and lower guides in the chassis, and slide the splitter into the slot until the front is flush with the chassis.


Note The slot splitter shown in Figure 3-31 has one open slot (top) and one slot with a slot cover (bottom)


Secure the slot splitter to the chassis by tightening the top and bottom captive screws (Figure 3-32).

Figure 3-30 HHGE Line Card Locations

 

Figure 3-31 Inserting the Slot Splitter

 

Figure 3-32 Captive Screw Locations

 

 


Warning Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement 1029



 

Installing the Half-Height Gigabit Ethernet Line Card

Use the following procedure to install a HHGE line card into an installed slot splitter. See the “Installing the Slot Splitter” section to install the slot splitter.

If you are replacing a line card, see the “Removing a Half-Height Gigabit Ethernet Line Card” section before you begin this procedure.


Step 1 Attach an antistatic wrist strap to your wrist and to an ESD socket on the chassis, or to a bare metal surface on the chassis or frame.

Figure 3-33 Inserting the Line Card

 

Step 2 Grasp the faceplate of the line card with one hand and place your other hand under the card carrier (to support the weight of the card). Position the card in front of the slot splitter.

Step 3 Carefully align the upper and lower edges of the line card with the upper and lower guides in the slot splitter, and slide the line card about half-way into the splitter.

Step 4 Be sure the ejectors are in the open position (as shown) and continue to push the line card into the splitter until you can feel it begin to seat in the backplane connectors.

Step 5 Verify that the captive screws are properly aligned with the captive screw holes in the splitter. If the captive screws are not properly aligned, the card will not seat properly in the backplane.

Step 6 Simultaneously pivot both ejector levers toward each other (until they are parallel to the faceplate) to firmly seat the card in the backplane (Figure 3-34).

The line card cycles through its power-on self-test. The FAIL LED lights during portions of the POST (Power-On Self Test), but remains off after POST on a properly working line card. If the FAIL LED remains on, go to the “Troubleshooting the HHGE Installation” section.

Figure 3-34 Closing the Ejector Levers

 

Figure 3-35 Captive Screw Locations

 

Step 7 Secure the line card in the slot splitter by tightening the top and bottom captive screws (Figure 3-35).


Caution To ensure that there is adequate space for additional line cards, always tighten the captive screws on each newly installed line card before you insert any additional line cards. These screws prevent accidental removal and provide proper grounding for electromagnetic interference (EMI) shielding.


 

Connecting the Console Port and Auxiliary Port

The PRE module on the Cisco uBR10012 router has two asynchronous serial (EIA/TIA-232) RJ-45 ports that provide connections for a console (an ASCII terminal or PC running terminal emulation software) and modem for remote access.

Recommended Tools and Supplies

The Cisco uBR10012 router arrives with a console and auxiliary cable kit, which contains the cable and adapters you need for the most common connections to these devices.

Table 3-6 lists the tools and supplies that you need to connect the Console and auxiliary ports.

 

Table 3-6 Tools and Supplies for Connecting the Console Port and Auxiliary Port

Quantity
Description
Comments

RJ-45 to RJ-45 crossover cable

RJ-45-to-DB-25 male DCE adapter

labeled MODEM

ESD-preventive wrist strap


Note A crossover cable reverses pin connections from one end to the other. In other words, it connects pin 1 (at one end) to pin 8 (at the other end), pin 2 to pin 7, pin 3 to pin 6, and so on. You can identify a crossover cable by comparing the two modular ends of the cable. Hold the cable ends in your hand, side-by-side, with the tabs at the back. Ensure that the wire connected to the outside (left) pin of the left plug (pin 1) is the same color as the wire connected to the outside (right) pin of the right plug (pin 8).

Also see “How to Identify an RJ-45 Crossover Cable” section.


Use the following procedures to connect to the console and auxiliary ports on a PRE module.


Note For more information about the console port and auxiliary port connectors, see the “Console and Auxiliary Port Cables and Pinouts” section.


Connecting to the Console Port

The console port provides local administrative access to the router and its command-line interface (CLI).


Note Each PRE module must have a console port connection (typically to a terminal server) when running a redundant configuration in the chassis.



Step 1 Connect one end of the RJ-45 crossover cable to the serial RJ-45 port (labelled CONSOLE) on the PRE module (Figure 3-36).

Figure 3-36 Console Port Connection on the PRE Module

 

Step 2 Run the other end of the crossover cable through the square hole at the left front side of the chassis, and connect it to the RJ-45-to-DB-9 adapter (see Figure 3-37):

Figure 3-37 Connecting an RJ-45-to-DB-9 Console Cable Adapter

 

Step 3 Connect the adapter to the appropriate serial port on the PC or terminal to complete the console port cable connection.

Step 4 Power on the PC or terminal.

Step 5 Configure the PC terminal emulation software or the terminal for the following default settings:

  • 9600 baud
  • 8 data bits
  • No parity generation or checking
  • 1 stop bit
  • No flow control

Step 6 If also connecting a modem to the auxiliary port, go to the next section, “Connecting to the Auxiliary Port.” Otherwise, go to the “Connecting Network Management Cables” section to continue the installation.


 

Connecting to the Auxiliary Port

The auxiliary port provides a connection for a modem to allow remote access to the router and its command-line interface (CLI).


Step 1 Connect one end of the RJ-45 crossover cable to the serial RJ-45 port (labelled AUX) on the PRE module (Figure 3-38).

Figure 3-38 Auxiliary Port Connection on the PRE Module

 

Step 2 Run the other end of the crossover cable through the square hole at the left front side of the chassis, and connect it to the RJ-45-to-DB-25 adapter.

Step 3 Connect the adapter to the serial port on the modem to complete the auxiliary port cable connection.

Step 4 Power on the modem.

Step 5 Make sure that the modem and auxiliary port on the router are configured for the same transmission speed (38.4 Kbps and 56 Kbps are typical). Configure the modem for auto-answer and for hardware flow control using the Data Carrier Detect (DCD) and Data Terminal Ready (DTR) signals.

Step 6 Go to the “Connecting Network Management Cables” section to continue the installation.


 

Connecting Network Management Cables

The Cisco uBR10012 router has connections to both the internal Ethernet management network and the external data network. The internal Ethernet management network connections are made through an Ethernet port on the front panel of the PRE module.These connections are described in the Ethernet Network Management Cable Connections.

Keep the following guidelines in mind when connecting external cables to the Cisco uBR10012 router:

  • To reduce the chance of interference, avoid crossing power lines with any interface cables.
  • Verify all cabling limitations (particularly distance) before powering on the system.

Ethernet Network Management Cable Connections

The PRE module provides an Ethernet port to a LAN for a 10Base-T or 100Base-T connection for network management. Use the following procedures to connect the Cisco uBR10012 router to an Ethernet network.


Note Each PRE module must have an Ethernet port connection (typically to the same Ethernet hub) if you are running a redundant configuration in the chassis. However, only the active PRE module has an active Ethernet connection to the network.


Connecting to a 10Base-T Ethernet Network

To make a 10Base-T Ethernet LAN connection, you need the following additional equipment (not included):

  • An Ethernet hub (such as a Cisco Micro Hub)
  • An Ethernet cable that meets the following specifications:

– RJ-45 (male) to RJ-45 (male) straight-through cable

– 100-ohm category 3, 4, or 5, no longer than 328 feet (100 meters)

You can identify a straight-through Ethernet cable either by using a cable tester or by making a visual inspection. To make a visual inspection, hold the two ends of a cable side by side, with the tab for each at the back.

  • The wire connected to the left-most pin (pin 1) on one connector should be the same color as the wire connected to the left-most pin on the other connector.
  • The same rule applies to pins 2 through 8 on each connector. The color of the wire attached to a pin on one connector should match the color of the wire attached to the corresponding pin on the other connector.

Follow these steps to connect the PRE to a 10Base-T Ethernet LAN.


Step 1 Connect one end of the Ethernet cable to the RJ-45 port on the primary PRE, labeled Ethernet (see Figure 3-39).

Step 2 Run the other end of the Ethernet cable through the square hole at the left front side of the chassis, and connect this end of the cable to any unoccupied port on the Ethernet hub.


Tip When power is applied to the chassis, check the LNK (Link) LED on the PRE faceplate port next to the Ethernet port. This LED lights (green) if the PRE is correctly connected to the 10Base-T Ethernet LAN.


Figure 3-39 Connecting 10Base-T to an Ethernet Port

 


 

Connecting to a 100Base-T Ethernet Network

To make a 100Base-T Ethernet LAN connection, you need the following additional equipment (not included):

  • An Ethernet hub (such as a Cisco Micro Hub)
  • An Ethernet UTP cable that meets the following specifications:

– RJ-45 (male) to RJ-45 (male) straight-through cable.

– 100-ohm category 5 cable not longer than 328 feet (100 meters).

You can identify a straight-through Ethernet cable either by using a cable tester or by making a visual inspection. To make a visual inspection, hold the two ends of a cable side by side, with the tab for each at the back.

  • The wire connected to the left-most pin (pin 1) on one connector should be the same color as the wire connected to the left-most pin on the other connector.
  • The same rule applies to pins 2 through 8 on each connector. The color of the wire attached to a pin on one connector should match the color of the wire attached to the corresponding pin on the other connector.

Caution If the Cisco uBR10012 router is used in an environment in which lightning-induced transients are likely to couple to the signal lines, use of shielded interconnection cables for the 100Base-T ports is highly recommended. In addition, use of shielded interconnection cables for the 100Base-T ports is required to meet Telcordia (formerly Bellcore) GR1089 CORE Section 4.5.9 and ETSI Section 5.2.2.2 (intrabuilding lightning surge).

The RJ-45 port on the PRE is configurable for 100-Mbps full-duplex or half-duplex operation (half-duplex is the default) and supports IEEE 802.3, Ethernet, and IEEE 802.3u interfaces compliant with 100Base-T specifications.

Follow these steps to connect the PRE to a 100Base-T Ethernet LAN.


Step 1 Connect one end of the Ethernet cable to the RJ-45 port on the primary PRE, labeled Ethernet (Figure 3-40).

Step 2 Run the cable up and through the cable management bracket and connect the other end of the Ethernet cable to any unoccupied port on the Ethernet hub.


Tip When power is applied to the chassis, check the LNK (Link) LED on the PRE faceplate port next to the Ethernet port. This LED lights (green) if the PRE is correctly connected to the 100Base-T Ethernet LAN.



 

Figure 3-40 Connecting 100Base-T to Ethernet Port

 

Connecting Cable Interface Line Cards and Network Uplink Cards

Because there are very specific requirements for cabling the different line cards and uplink cards used with the Cisco uBR10012 CMTS, please review the documentation for the cards that you are installing in your system.

Cable Interface Line Card Connections

For cabling instructions, refer to the appropriate cable interface line card documentation at the following URL:

http://www.cisco.com/en/US/products/hw/cable/ps2209/prod_installation_guides_list.html

Network Uplink Cable Connections

These cards use fiber optic connections which require specific cleaning and preparation before they are cabled. For cleaning and inspecting instructions for the fiber optic connections, see Inspection and Cleaning Procedures for Fiber-Optic Connections at the following URL:

http://www.cisco.com/en/US/tech/tk482/tk876/technologies_white_paper09186a0080254eba.shtml

For cabling instructions, refer to the appropriate network uplink card documentation at the following URL:

http://www.cisco.com/en/US/products/hw/cable/ps2209/prod_installation_guides_list.html


Warning Class 1 laser product. Statement 1008



Warning Invisible laser radiation present. Statement 1016.



Warning Because invisible laser radiation may be emitted from the aperture of the port when no cable is connected, avoid exposure to laser radiation and do not stare into open apertures. Statement 1056.


Warning Statement for Sweden


Warning Osynlig laserstrålning när denna del är öppen och förregleringen är urkopplad. Rikta inte blicken in mot strålen. Statement 36.


Warning Statement for Finland


Warning Alleviates ja suojalukitus ohitettaessa olet alttiina näkymättömälle lasersäteilylle. Äjä katso säteeseen. Statement 35



Note If you have completed all cable connections, go to the “Replacing the Front Cover” section to continue the installation. If you are using Gigabit Ethernet line cards, go to “Connecting a Single-Port Gigabit Ethernet Line Card” section.


Connecting a Single-Port Gigabit Ethernet Line Card

The single-port Gigabit Ethernet (GE) line card provides a trunk uplink running at 1 Gbps in full duplex mode to devices such as content servers and Web caches. The port uses a Gigabit Interface Converter (GBIC) that supports Gigabit Ethernet rates on a variety of Gigabit Ethernet interface types (SX, LX/LH, ZX). For a list of qualified GBICs and cable lengths, see Table 1-9 .

Use the following procedure to install a GBIC and then connect a fiber cable to the GBIC.


Note If a GBIC is already installed in the GE line card, begin this procedure at Step 2.



Step 1 Review the warnings at the start of the network uplink section.

Step 2 Insert the GBIC into the GE line card port until the tabs lock into place (Figure 3-41).

Figure 3-41 Inserting the GBIC

 


Note The GBIC is “keyed” and can only be fully inserted one way. If you can only insert the GBIC one quarter of the way into the port, remove it, turn it over, and reinsert it into the port.


Step 3 Remove the protective plug from the GBIC by pulling it off.


Caution Make sure your fiber optic connectors are clean and debris free. Refer to Inspection and Cleaning Procedures for Fiber-Optic Connections at the following URL:

http://www.cisco.com/en/US/tech/tk482/tk876/technologies_white_paper09186a0080254eba.shtml

Step 4 Attach the fiber optic cable to the GBIC port (Figure 3-42).

Figure 3-42 Connecting the Cable to the GBIC Port

 

Step 5 Run the cable through the cable bracket on the bottom of the line card and then out to the left or right of the chassis (Figure 3-43).

Figure 3-43 Gigabit Ethernet Cable Management

 

Step 6 If you have completed all cable connections, go to the next section, “Replacing the Front Cover” to continue the installation.


 

Replacing the Front Cover

Use the following procedure to replace the front cover on the chassis:


Step 1 Slide the cover onto the four corner posts of the chassis and then push down so that the posts are seated in the grooves above the cover holes (Figure 3-44).

Figure 3-44 Attaching the Cover to the Chassis

 

Step 2 Continue with the “Powering On the System” section to continue the installation.


 

Powering On the System

After all of the interfaces and other cables are connected, perform a visual check of all connections and then check that:

  • The ejector levers on each line card are in the locked position.
  • All top and bottom line card captive screws are tight.
  • All network interface cables are connected.
  • The console terminal is turned on.
  • A PC media card is installed in the PRE module.

For information on powering up the Cisco uBR10012 router using the UBR10-PWR-DC= DC PEM module, see DC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .

For information on powering up the Cisco uBR10012 router using the UBR10-PWR-DC-PLUS= DC PEM module, see 3300 W DC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .

For information on powering up the Cisco uBR10012 router using the UBR10-PWR-AC= AC PEM module, see AC Power Entry Module for the Cisco uBR10012 Universal Broadband Router .

For information on powering up the Cisco uBR10012 router using the UBR10-PWR-AC-PLUS= AC PEM module, see 3300 W AC Power Entry Module for the Cisco uBR10012 Universal Broadband Router.


 

Configuring the Cisco uBR10012 Router at Startup

This section explains how to create a basic running configuration for your Cisco uBR10012 router using the Cisco uBR10012 router setup facility or the IOS command line interface (CLI). For information on modifying the configuration after you create it, refer to:

  • The online Cisco uBR10012 Router Useful Links document
  • Cisco IOS configuration and command reference guides

To configure a Cisco uBR10012 router from the console, you must connect a terminal or terminal server to the router's console port. To configure the Cisco uBR10012 router over your management Ethernet, you must have available the router’s IP address.

Startup Display

When you power on your Cisco uBR10012 router or execute the reload command, the console screen displays a message similar to the following:

Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
 
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
 
Cisco Internetwork Operating System Software
IOS (tm) 10012 Software (UBR10K-P6-M), Released Version 12.2(1)
Copyright (c) 1986-2001 by cisco Systems, Inc.
Compiled Thu 19-Apr-01 13:47 by samants
Image text-base: 0x60008960, data-base: 0x612B0000
 
ROM: System Bootstrap, Version 12.0(9r)SL1, RELEASE SOFTWARE (fc1)
BOOTFLASH: 10012 Software (C10K-EBOOT-M), Released Version 12.1(5)
 
System returned to ROM by reload at 12:59:35 PDT Thu Apr 19 2001
System restarted at 13:00:51 PDT Thu Apr 19 2001
 
cisco C10012 (PRE-RP) processor with 98304K/32768K bytes of memory.
Processor board ID ABCDEFEDCBA
R7000 CPU at 262Mhz, Implementation 39, Rev 2.1, 256KB L2, 2048KB L3 Cache
Backplane version 1.0, 16 slot
 
Last reset from unexpected value
Toaster processor tmc0 is running.
Toaster processor tmc1 is running.
1 Ethernet/IEEE 802.3 interface(s)
1 FastEthernet/IEEE 802.3 interface(s)
1 Gigabit Ethernet/IEEE 802.3 interface(s)
3 Cable Modem network interface(s)
509K bytes of non-volatile configuration memory.
 
16384K bytes of Flash PCMCIA card at slot 1 (Sector size 128KB).
32768K bytes of Flash internal SIMM (Sector size 256KB).
Press RETURN to get started!

Basic Configuration Using the Setup Facility

The first time you power on a Cisco uBR10012 router, the setup facility starts. You can also initiate the facility by running the setup command in privileged EXEC mode. This facility helps you enhance a default configuration that already exists on the Cisco uBR10012 router. The setup facility uses a question and answer sequence called the System Configuration Dialog to walk you through configuring the router.

You do not have to configure the interfaces immediately; however, you cannot enable the interfaces or connect them to any networks until you have configured them.


Tip Basic configuration setup is often used as a quick way to achieve network connectivity, allowing you to retrieve a configuration file from a TFTP server.


System Configuration Dialog

Use the System Configuration Dialog to help you perform a basic configuration. Proceed through the dialog by answering questions and then pressing the Enter key. In most cases, you can get additional information by entering a question mark (?). Throughout the dialog, default values are shown in square brackets [ ].


Tip If you have experience using Cisco routers, consider configuring the router by using the procedure described in the “Basic Configuration in Global Configuration Mode” section.


To cancel the configuration dialog, press Ctrl-C , or you can let the dialog help you perform one of two configuration types:

  • Basic configuration setup configures only enough connectivity for management of the system.
  • Extended setup asks you to configure each interface and is not appropriate for configuring the Cisco uBR10012 router. For more information, see the Cisco IOS Configuration Fundamentals Configuration Guide.

You can run the setup facility any time you are at the enable prompt (#) by entering the command setup .

Configuring the System Using System Configuration Dialog

Use the following procedure to perform a basic configuration using the System Configuration Dialog:


Step 1 The dialog starts by asking if you want to continue with the configuration dialog. Enter Yes. To return to the enable prompt, enter No.

--- System Configuration Dialog ---
Continue with configuration dialog? [yes/no]: yes
 

Step 2 Enter Yes to perform a basic management setup. Enter No to perform an extended configuration setup.

Would you like to enter basic management setup? [yes/no]: yes
 

Step 3 Specify a hostname. The hostname becomes part of the IOS prompt.

Enter host name [Router]: my-router
 

Step 4 Specify a secret password. It appears in encrypted form in the configuration file.

Enter enable secret: my_secret
 

Step 5 Specify the enable password. It is used if you did not assign a secret one.

Enter enable password: my_password
 

Step 6 Specify the password to use for telnet sessions.

Enter virtual terminal password: my_vt
 

Step 7 At the configure system management prompt, enter No.

Configure System Management? [yes/no]: no
 

Step 8 If you want to access the router using SNMP, enter Yes at the prompt:

Configure SNMP Network Management? [yes]: yes
 

Step 9 Specify an SNMP community string.

Community string [public]: public
 


 

Setting Up the Interface

After you respond to the SNMP questions, the setup script lists the interfaces. The following table lists typical interfaces found on a Cisco uBR10012 router.

 

Interface
IP-Address
OK?
Method
Status
Protocol
Ethernet0/0/0

unassigned

YES

unset

up

up

FastEthernet0/0/0

unassigned

NO

unset

up

up

GigabitEthernet3/0/0

unassigned

NO

unset

up

up

Cable6/1/0

unassigned

NO

unset

up

up

Cable6/1/1

unassigned

NO

unset

up

up

Cable7/0/0

unassigned

NO

unset

up

up


Tip Interfaces that are not okay (NO) do not have a valid configuration.


To set up an interface on the Cisco uBR10012 router:


Step 1 Enter the interface for the FastEthernet interface to achieve network connectivity.

Enter interface name used to connect to the management network from the above interface summary: FastEthernet0/0/0
 

Step 2 Accept the default value for the type of connector. RJ-45 is the only connector that can be used on the Cisco uBR10012 router Ethernet port.

Configuring interface FastEthernet0/0/0:
Use the 100 Base-TX (RJ-45) connector? [yes]: yes
 

Step 3 Configure both the Cisco uBR10012 router and the remote device to use the same mode.

Operate in full-duplex mode? [no]: no
 

Step 4 Enter the IP address to achieve network connectivity.

Configure IP on this interface? [yes]: yes

Step 5 Specify the IP address.

IP address for this interface: 172.27.48.209
 

Step 6 Enter the subnet mask for the IP address.

Subnet mask for this interface [255.255.0.0]: 255.255.0.0
 

The system displays the information you entered as well as several default commands, such as the no shutdown command. For example:

The following configuration command script was created:
hostname c10012
enable secret 5 $$1$uror$EFU0hKOBQXhk975qKFZlL0
enable password <xxx>
line vty 0 4
password <xxx>
no snmp-server
!
no ip routing
!
interface FastEthernet0/0/0
no shutdown
media-type 100BaseX
half-duplex
ip address 172.27.48.209 255.255.0.0
!
end
 

Step 7 Exit the setup script without saving, start the setup script, or save the configuration file:

[0] Go to the IOS command prompt without saving this config.
[1] Return back to the setup without saving this config.
[2] Save this configuration to nvram and exit.
 
Enter your selection [2]:
 

Step 8 Enter global configuration mode after you complete the configuration, and enable ip routing by entering the ip routing command:

router(config)#ip routing


 

Basic Configuration in Global Configuration Mode

The following command sequence allows you to perform a configuration similar to that generated by the setup command.

Router>configure terminal
Router(config) #hostname c10012
Router(config) #enable secret <my_router>
Router(config) #enable password <my_rtr>
Router(config) #snmp-server community public
Router(config) #ip routing
Router(config) #interface FastEthernet0/0/0
Router(config-if) #no shutdown
Router(config-if) #media-type 100BaseX
Router(config-if) #half-duplex
Router(config-if) #ip address 192 255.255.0.0
Router #copy running-config startup-config

You can now configure the line cards. For specific information on system and interface configuration, refer to the Cisco uBR10012Universal Broadband Router Software Configuration Guide at the following URL:

http://www.cisco.com/en/US/docs/cable/cmts/ubr10012/configuration/guide/scg.html

Formatting PC Media Cards

The PC media card that shipped with your PRE contains the default Cisco IOS image for booting your router. This section explains how to format a PC media card, modify its contents, or resolve a problem with the card.


Caution The formatting procedure erases all information on the PC media card.


Note The Cisco uBR10012 router uses PC media cards that are a minimum of 64 MB in size.


Flash memory ATA disks and Flash memory cards use similar commands. The primary syntax change is that disk0: or disk1: refers to Flash memory ATA disks while slot0: or slot1: refers to Flash memory cards.

Use the following procedure to format a Flash memory disk:


Step 1 Ensure there is a PC media card in slot 0 or slot 1 of the PRE.

Step 2 Enter the format disk n : command at the privileged EXEC mode prompt to format the card. The example shows the display after you enter the format disk0: command:

Router# format disk0:
All sectors will be erased, proceed? [confirm]
Enter volume id (up to 30 characters): MyNewdisk
Formatting sector 1
Format device slot0 completed

The PC media card is ready for use.