Overview

Overview

The Cisco Nexus 9364D-GX2A switch (N9K-C9364D-GX2A) is a 2-rack unit (RU), fixed-port switch designed for deployment in data centers.

This switch includes the following ports:

  • 400-Gigabit QSFP-DD ports (64)

  • 10-Gigabit SFP+ ports (2)

  • Management ports (one RJ-45 port and one SFP port)

  • Console port

  • USB port


Note


Dust covers (NXA-ACC-QDD-DC) are suggested for unused ports, to protect the connectors and help divert airflow for thermal dispensation.


This switch includes the following high power optics and MACsec:

  • 16 ports of MACsec with no ports of 20-W optics

  • 8 ports of MACsec with 8 ports of 20-W optics

  • No ports of MACsec with 16 ports of 20-W optics


    Note


    For this switch, 20-W optics can go in any of the 32 odd numbered QSFP-DD ports.


This switch includes the following user-replaceable components:

  • Fan modules (four) with the following airflow choices:

    • Port-side intake fan module with burgundy coloring (NXA-FAN-160CFM2-PI)


      Note


      If a fan fails, the other fans are automatically increased to 100% capacity to compensate. If two fans fail, then multi fan failure policy kicks in, the switch will issue a warning, and power down in 2 minutes.


  • Power supply modules (two—One for operations and one for redundancy [1+1]) with the following choices:

    • 3200-W port-side intake AC/HVDC power supply with burgundy coloring (NXA-PAC-3200W-PI)

    • 3200-W port-side intake DC/HVDC power supply with burgundy coloring (NXA-PDC-3200W-PI)


    Note


    Both power supplies are the same type. Do not mix AC, and DC, power supplies.


The following figure shows the switch features on the port side of the chassis.

1

SFP optical management port (1)

4

USB port (1)

2

Console port (1)

5

10-Gigabit SFP+ ports (2)

3

RJ-45 copper management port (1)

6

400-Gigabit QSFP-DD ports (64)

To determine which transceivers, adapters, and cables are support this switch, see the Cisco Transceiver Modules Compatibility Information document.

The following figure shows the switch features on the power supply side of the chassis.

1

Fan modules (4) with slots numbered from 1 (left) to 4 (right)

2

Power supply modules (1 or 2) (AC power supplies shown) with slots numbered 1 (top) and 2 (bottom)

The following figure shows the side of the chassis.

1

Grounding pad

The fan and power supply modules are field replaceable. You can replace one fan module or one power supply module during operations so long as the other modules are installed and operating. If you have only one power supply installed, you can install the replacement power supply in the open slot before removing the original power supply.


Note


All fan and power supply modules must have the same direction of airflow. Otherwise, the switch can overheat and shut down. If you are installing a dual-direction power supply, that module automatically uses the same airflow direction as the other modules in the switch.



Caution


The switch has port-side intake airflow (burgundy coloring for fan modules), so you must locate the ports in the cold aisle. If you locate the air intake in a hot aisle, the switch can overheat and shut down.