Safety and Installation Warnings
WarningRead the safety warnings and installation instructions before using, installing or connecting the system to the power source.
Personnel
Only a skilled person or an instructed person should be allowed to install, replace, or service this equipment.
Environment
Access
This unit is intended for installation in restricted access areas. A restricted access area can only be accessed by skilled, instructed or qualified personnel.
GPS
To reduce the risk of electric shock, the shield of the coaxial cable must be connected to the building earth.
Ambient temperature
Make sure the ambient temperature does not exceed the maximum ambient temperature allowed for the Cisco Nexus 3550-T Programmable Switch Platform (104F, 40C). If installed in a closed or multi-unit rack assembly, the ambient temperature of the rack during operation will be greater than room ambient.
Air flow
Install the Nexus 3550-T in the rack in a way that provides sufficient air flow for safe operation.
Mechanical loading
Mount the Nexus 3550-T in the rack with a mechanical load that is evenly distributed and not excessive.
Circuit overloading
Ensure that no overloading of the circuits occurs which might affect overcurrent protection and supply wiring. The ratings are provided on the unit.
Earthing
Ensure that the rack-mounted equipment is earthed reliably. Consider using supply connections other than direct connections to the branch circuit (e.g. use of power strips).
Power
Check that your Nexus 3550-T is rated to be used with the mains power in your country.
Total Nexus 3550-T rating: - 90-264V AC @ 6A max, 47/63 Hz
Before Servicing
Disconnect the two power supply cables before servicing.
Power Cables
Ensure the Nexus 3550-T uses mains power cables approved in the country of operation.
Clock Battery
Laser Safety
21 CFR 1040
Pluggable optical modules comply with IEC 60825-1 Ed. 3 and 21 CFR 1040.10 and 1040.11 with or without exception for conformance with IEC 60825-1 Ed. 3 as described in Laser Notice No. 56, dated May 8, 2019.
Conforme à la norme 21 CFR 1040.10 et 1040.11, sauf conformité avec la norme IEC 60825-1 Ed. 3., comme décrit dans l’avis relatif au laser no. 56, daté du 8 mai 2019.
Caution
To reduce risk of electric shock or fire, installation of the equipment must comply with local and national electrical codes. This equipment must be grounded. To reduce the risk of electric shock, the power cord, plug or combination must be connected to a properly grounded electrode, outlet or terminal. Verification of the protective earthing of the socket outlet should be carried out by a skilled person.
Warranty Void if Opened
Do not open the case of the Nexus 3550-T. The warranty of the Nexus 3550-T will be void if the case is opened.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.