E Show Commands

show ecp

show ecp [ detail ] [ __readonly__ <ecp_rte> <ecp_retries> [ <ecp_mode> ] <ecp_cnt_rx_pkt> <ecp_cnt_tx_pkt> [ { TABLE_ecp_plugin <plugin_id> <plugin_desc> <plugin_status> } ] [ { TABLE_ecp_session <session_id> <session_interface> <session_svlan> [ <session_peer_mac> ] <session_rx_seq> <session_tx_seq> [ <session_cnt_rx_pkt> ] [ <session_cnt_rx_dup> ] [ <session_cnt_rx_drop> ] [ <session_cnt_tx_pkt> ] [ <session_cnt_tx_retry> ] [ <session_cnt_tx_err> ] } ] ]

Syntax Description

show

Show running system information

ecp

ECP (Edge Control Protocol)

detail

(Optional) Detailed information

__readonly__

(Optional)

ecp_rte

(Optional) Retransmission timer init exponent

ecp_retries

(Optional) Maximal number of retransmissions

ecp_mode

(Optional) ECP mode

ecp_cnt_rx_pkt

(Optional) No. received packet

ecp_cnt_tx_pkt

(Optional) No. trasmitted packet

TABLE_ecp_plugin

(Optional) ECP plugin table

plugin_id

(Optional) Plugin id

plugin_desc

(Optional) Plugin description

plugin_status

(Optional) Plugin status

TABLE_ecp_session

(Optional) ECP session table

session_id

(Optional) Session id

session_svlan

(Optional) S-Vlan

session_peer_mac

(Optional) Peer mac

session_interface

(Optional) Interface

session_rx_seq

(Optional) Receive sequence

session_tx_seq

(Optional) Transmit sequence

session_cnt_rx_pkt

(Optional) No. receive packet

session_cnt_rx_dup

(Optional) No. receive duplicate

session_cnt_rx_drop

(Optional) No. receive drop

session_cnt_tx_pkt

(Optional) No. transmit packet

session_cnt_tx_retry

(Optional) No. transmit retry

session_cnt_tx_err

(Optional) No. transmit error

Command Mode

  • /exec

show elam report

show elam report [ l2 | l3 | l4 | aclqos | mcast | mpls ]

Syntax Description

show

Show running system information

elam

elam

report

Show ELAM report

l2

(Optional) Layer 2 header report

l3

(Optional) Layer 3 header report

l4

(Optional) Layer 4 header report

aclqos

(Optional) Aclqos report

mcast

(Optional) Multicast report

mpls

(Optional) MPLS report

Command Mode

  • /exec/elamtah/outsel2

show email

show email [ __readonly__ [ <ipv4> ] [ <ipv6> ] [ <host> ] [ <port> ] [ <reply> ] [ <from> ] [ <vrfname> ] ]

Syntax Description

show

Show running system information

email

Pipe email configuration

__readonly__

(Optional)

ipv4

(Optional)

ipv6

(Optional)

host

(Optional)

port

(Optional)

reply

(Optional)

from

(Optional)

vrfname

(Optional)

Command Mode

  • /exec

show encryption service status

show encryption service status [ __readonly__ [ <encryptionService> <MasterKeyEncryption> <Type6Encryption> ] ]

Syntax Description

show

Show running system information

encryption

Encryption service

service

Encryption service

status

Encryption service status

__readonly__

(Optional)

encryptionService

(Optional) Encryption service status

MasterKeyEncryption

(Optional) Master key status

Type6Encryption

(Optional) Is type 6 encryption used?

Command Mode

  • /exec

show environment

show environment [ fan [ detail1 ] | power [ detail ] [ ampere ] [ input ] | temperature [ module <module> | <s0> <santa-cruz-range> | psu ] ] [ __readonly__ [ { TABLE_clockinfo <clockname> <clkmodel> <clkhwver> <clkstatus> <act_standby> } ] [ { fandetails [ { TABLE_faninfo <fanname> <fanmodel> <fanhwver> <fandir> <fanstatus> } ] { TABLE_fan_zone_speed <zone> <zonespeed> } [ <fan_filter_status> ] [ { TABLE_fantray <fanname> <trayfannum> <fandir> <fanperc> <fanrpm> } ] [ { TABLE_psufan <fanname> <fan1rpm> <fan2rpm> } ] } ] [ { powersup [ <voltage_level> ] [ { TABLE_psinfo <psnum> <psmodel> [ <actual_out> ] [ <actual_input> ] [ <tot_capa> ] [ <input_type> ] [ <watts> ] [ <amps> ] [ <ps_status> ] [ <ps_status_3k> ] } ] [ { TABLE_mod_pow_info <modnum> <mod_model> [ <actual_draw> ] [ <allocated> ] [ <watts_requested> ] [ <amps_requested> ] [ <watts_alloced> ] [ <amps_alloced> ] [ <modstatus> ] [ <modstatus_3k> ] } ] [ { power_summary [ <ps_redun_mode> ] [ <ps_redun_mode_3k> ] [ <ps_oper_mode> ] [ <ps_redun_op_mode> ] <tot_pow_capacity> [ <tot_gridA_capacity> ] [ <tot_gridB_capacity> ] [ <cumulative_power> ] [ <tot_pow_out_actual_draw> ] [ <tot_pow_input_actual_draw> ] [ <tot_pow_alloc_budgeted> ] [ <reserve_sup> ] [ <pow_used_by_mods> ] <available_pow> } ] [ { powersup_detail [ <reserve_sup> ] [ <reserve_xbar> ] [ <reserve_fan> ] [ <reserve_supxbarfan> ] [ <pow_used_by_mods> ] } ] [ <all_inlets_connected> ] [ { TABLE_ps_detail_info <det_name> <det_total_cap> <det_volt> <det_pintot> [ <det_pina> ] <det_vin> <det_iin> <det_pout> <det_vout> <det_iout> [ <det_pinb> ] [ <det_iinb> ] [ <det_vinb> ] [ <det_cord> ] <det_sw_alarm> [ { TABLE_det_hw_alarm_regval <regnum> <regval> } ] [ { TABLE_det_hw_alarm_str <regnumstr> <bitnumstr> <alarm_str> } ] } ] [ { TABLE_psinputinfo_n3k <ps_slot> <ps_input_voltage> <ps_input_current> [ <ps_in_power> ] [ <ps_output_voltage> ] [ <ps_output_current> ] <ps_state> } ] } ] [ { fandetails_3k [ { TABLE_faninfo <fanname> <fanmodel> <fanhwver> <fandir> <fanstatus> } ] { TABLE_fan_zone_speed <zone> <speed> } <fan_filter_status> [ { TABLE_fantray <fanname> <fannum> <fandir> <fanperc> <fanrpm> } ] [ { TABLE_psufan <fanname> <fan1rpm> <fan2rpm> } ] } ] [ { TABLE_tempinfo <tempmod> <sensor> <majthres> <minthres> <curtemp> <alarmstatus> [ <temptype> ] } ] [ { TABLE_psutempinfo <psumod> <inlet_temp> <outlet_temp> <heatsink_temp> } ] ]

Syntax Description

show

Show running system information

environment

system environment information

fan

(Optional) Fan information

power

(Optional) Power capacity and power distribution information

detail

(Optional) Detail Fan-tray information when used with Fan. Detail Power capacity and power distribution information when used with Power

detail1

(Optional) Detail Fan-tray information when used with Fan

ampere

(Optional) Ampere Power capacity and power distribution information

input

(Optional) Power supply power input

temperature

(Optional) temperature sensor information

module

(Optional) enter a module number

module

(Optional) please enter the module number

s0

(Optional) xbar

santa-cruz-range

(Optional) please enter the xbar number

psu

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

__readonly__

(Optional)

TABLE_clockinfo

(Optional) Environment Clock

clockname

(Optional) Clock Instance (A or B)

clkmodel

(Optional) Model number of clock

clkhwver

(Optional) Hardware version of the clock

clkstatus

(Optional) Present/Absent Status of the clock

act_standby

(Optional) Active/Standby Status of clock

fandetails

(Optional) Environment Fan

TABLE_faninfo

(Optional) Fan Info

fanname

(Optional) Fan Instance

fanmodel

(Optional) Model number of fan

fanhwver

(Optional) Hardware version of the fan

fandir

(Optional) Air-flow direction of the fan-tray

fanstatus

(Optional) Present/Absent Status of the fan

TABLE_fan_zone_speed

(Optional) Fan Zone Speeds

zone

(Optional) Zone Number

zonespeed

(Optional) Zone Speed

fan_filter_status

(Optional) Present/Absent Status of fan filter

TABLE_fantray

(Optional) Fan Tray Details table

fanname

(Optional) Fan Tray Instance

trayfannum

(Optional) Fan number in the tray

fandir

(Optional) Air-flow direction of the fan-tray

fanperc

(Optional) FAN Speed percentage

fanrpm

(Optional) FAN Speed RPM

TABLE_psufan

(Optional) PSU Fan Details table

fanname

(Optional) PSU Fan Instance

fan1rpm

(Optional) FAN1 Speed RPM

fan2rpm

(Optional) FAN2 Speed RPM

fandetails_3k

(Optional) Environment Fan

TABLE_faninfo

(Optional) Fan Info

fanname

(Optional) Fan Instance

fanmodel

(Optional) Model number of fan

fanhwver

(Optional) Hardware version of the fan

fandir

(Optional) Air-flow direction of the fan-tray

fanstatus

(Optional) Present/Absent Status of the fan

TABLE_fan_zone_speed

(Optional) Fan Zone Speeds

zone

(Optional) Zone Number

speed

(Optional) Zone Speed

fan_filter_status

(Optional) Present/Absent Status of fan filter

TABLE_fantray

(Optional) Fan Tray Details table

fanname

(Optional) Fan Tray Instance

fannum

(Optional) Fan number in the tray

fandir

(Optional) Air-flow direction of the fan-tray

fanperc

(Optional) FAN Speed percentage

fanrpm

(Optional) FAN Speed RPM

TABLE_psufan

(Optional) PSU Fan Details table

fanname

(Optional) PSU Fan Instance

fan1rpm

(Optional) FAN1 Speed RPM

fan2rpm

(Optional) FAN2 Speed RPM

powersup

(Optional) Environment Power

voltage_level

(Optional) Voltage Level

TABLE_psinfo

(Optional) Power Supply Info

psnum

(Optional) Power Supply Number

psmodel

(Optional) Power Supply Model

actual_out

(Optional) Actual Output

actual_input

(Optional) Actual Input

tot_capa

(Optional) Total Capacity

input_type

(Optional) Power Supply Input Type

watts

(Optional) Power in Watts

amps

(Optional) Power in Amps

ps_status

(Optional) Power Supply Status

ps_status_3k

(Optional) Power Supply Status

TABLE_mod_pow_info

(Optional) Module Power Info

modnum

(Optional) Module number

mod_model

(Optional) Model ProductID number

actual_draw

(Optional) Actual Draw

allocated

(Optional) Power allocated

watts_requested

(Optional) Power requested in Watts

amps_requested

(Optional) Power requested in Amps

watts_alloced

(Optional) Power allocated in Watts

amps_alloced

(Optional) Power allocated in Amps

modstatus

(Optional) Module Status

modstatus_3k

(Optional) Module status

power_summary

(Optional) Power Usage Summary

ps_redun_mode

(Optional) Mode: Redundant or Non-redundant

ps_redun_mode_3k

(Optional) Mode: Redundant or Non-redundant

ps_redun_op_mode

(Optional) Operational mode: Redundant or Non-redundant

ps_oper_mode

(Optional) Operational Mode

tot_pow_capacity

(Optional) Total Power Capacity

tot_gridA_capacity

(Optional) Total Grid-A Capacity

tot_gridB_capacity

(Optional) Total Grid-B Capacity

cumulative_power

(Optional) Total Power of all Inputs

tot_pow_out_actual_draw

(Optional) Total Power Output, Actuals

tot_pow_input_actual_draw

(Optional) Total Power Input, Actuals

tot_pow_alloc_budgeted

(Optional) Total Power Allocated/budgeted

reserve_sup

(Optional) Power reserved for Supervisors

pow_used_by_mods

(Optional) Power currently used by Modules

available_pow

(Optional) Remaining Power Available

powersup_detail

(Optional) PowerSupply Details

reserve_sup

(Optional) Power reserved for Supervisors

reserve_xbar

(Optional) Power reserved for Xbars

reserve_fan

(Optional) Power reserved for Fans

reserve_supxbarfan

(Optional) Total Power reserved for Sups,Xbars,Fans

pow_used_by_mods

(Optional) Power currently used by Modules

all_inlets_connected

(Optional) Are all inlet cords connected

TABLE_ps_detail_info

(Optional) Power supply detail information

det_name

(Optional) Power supply name

det_total_cap

(Optional) Power supply total capacity

det_volt

(Optional) Power supply voltage

det_pintot

(Optional) Power supply pin A total power

det_pina

(Optional) PS pin A

det_vin

(Optional) PS Vin

det_iin

(Optional) PS Iin

det_pout

(Optional) PS Power out

det_vout

(Optional) PS voltaget out

det_iout

(Optional) PS current in

det_pinb

(Optional) PS pin B

det_iinb

(Optional) PS Iin B

det_vinb

(Optional) PS Vin B

det_cord

(Optional) PS cord

det_sw_alarm

(Optional) PS software alarm

TABLE_det_hw_alarm_regval

(Optional) PS hardware alarm

regnum

(Optional) HW alarm register

regval

(Optional) Alarm reg value

TABLE_det_hw_alarm_str

(Optional) PS Hardware alarm string

regnumstr

(Optional) Alarm reg number

bitnumstr

(Optional) Alarm register bit

alarm_str

(Optional) Alarm cause

TABLE_psinputinfo_n3k

(Optional) Power Supply power input

ps_slot

(Optional) Power Supply Number

ps_input_voltage

(Optional) Power Supply input volatage

ps_input_current

(Optional) Power Supply input current

ps_in_power

(Optional) Power Supply input power

ps_output_voltage

(Optional) Power Supply output volatage

ps_output_current

(Optional) Power Supply output current

ps_state

(Optional) Power Supply status

TABLE_tempinfo

(Optional) Environment Temperature

tempmod

(Optional) Module

sensor

(Optional) Sensor name

majthres

(Optional) Major Threshold

minthres

(Optional) Minor Threshold

curtemp

(Optional) Current temperature

alarmstatus

(Optional) Alarm Status

temptype

(Optional) Control or Monitor temparature

TABLE_psutempinfo

(Optional) PSU temperature info table

psumod

(Optional) PSU Module

inlet_temp

(Optional) Inlet Temperature

outlet_temp

(Optional) Outlet Temperature

heatsink_temp

(Optional) Heatsink Temperature

Command Mode

  • /exec

show epbr policy

show epbr policy [ <policy-name> ] [ reverse ] [ __readonly__ TABLE_pmap <pname> [ { TABLE_pmap_match <match_type> <match_stmt> <action> [ { TABLE_pmap_s_chain <seq> <sname> <action> [ { TABLE_pmap_s_chain_entry <ip_type> <svc_ep> [ <track_id> ] [ <probe_state> ] } ] } ] } ] [ <intf_name> ] + ]

Syntax Description

show

Show running system information

epbr

Show information about epbr

policy

EPBR policy name

policy-name

(Optional) Policy name

reverse

(Optional) Apply the policy in reverse dir

__readonly__

(Optional) Read Only

TABLE_pmap

(Optional)

pname

(Optional) Policy Name

TABLE_pmap_match

(Optional)

match_type

(Optional) Match Type

match_stmt

(Optional) Match Statement

action

(Optional) Traffic action

TABLE_pmap_s_chain

(Optional)

seq

(Optional) Sequence Number

sname

(Optional) Service Name

action

(Optional) Action

TABLE_pmap_s_chain_entry

(Optional)

ip_type

(Optional) IP type

svc_ep

(Optional) Service Endpoint

track_id

(Optional) Track ID

probe_state

(Optional) Probe State

intf_name

(Optional) Interface Name

Command Mode

  • /exec

show epbr statistics policy

show epbr statistics policy <policy-name> [ reverse ] [ __readonly__ TABLE_pmap <pname> <match_stmt> <bcount> [ { TABLE_pmap_t_match <bname> [ { TABLE_pmap_b_stats <sname> <pval> <action> } ] } ] ]

Syntax Description

show

Show running system information

epbr

Show information about epbr

statistics

EPBR Statistics

policy

EPBR Policy

policy-name

Policy name

reverse

(Optional) Apply the policy in reverse dir

__readonly__

(Optional) Read Only

TABLE_pmap

(Optional)

pname

(Optional) Policy Name

match_stmt

(Optional) Match Statement

bcount

(Optional) Bucket Count

TABLE_pmap_t_match

(Optional)

bname

(Optional) Bucket Name

TABLE_pmap_b_stats

(Optional)

sname

(Optional) Service Name

pval

(Optional) Packet Value

action

(Optional) Action

Command Mode

  • /exec

show errdisable detect

show errdisable { detect | recovery } [ __readonly__ TABLE_errdisable <cause> <state> [ <time_interval> ] ]

Syntax Description

show

Show running system information

errdisable

Error disable

detect

Show errdisable detect

recovery

Show errdisable recovery

__readonly__

(Optional) Read Only

TABLE_errdisable

(Optional) show errdisable

cause

(Optional) errdisable cause

state

(Optional) Interface state

time_interval

(Optional) err revovery time interval

Command Mode

  • /exec

show errdisable flap

show errdisable flap

Syntax Description

show

Show running system information

errdisable

Error disable

flap

linkstate flapping

Command Mode

  • /exec

show esmc counters interface

show esmc counters { interface <if0> | all } [ __readonly__ [ TABLE_esmc <intf_name> <esmc_infos_sent> <esmc_events_sent> <esmc_dnus_sent> <esmc_infos_rcvd> <esmc_events_rcvd> <esmc_dnus_rcvd> <esmc_malformed_rcvd> <esmc_rcvd_error> ] <esmc-end> ]

Syntax Description

show

Show running system information

esmc

Ethernet Synchronization Messaging Channel

__readonly__

(Optional) Read Only

counters

Display ESMC packet counters

interface

Enter the port interface

if0

all

Displays all information

TABLE_esmc

(Optional) Start of table

intf_name

(Optional) Interface name

esmc_infos_sent

(Optional) esmc infos sent

esmc_events_sent

(Optional) esmc events sent

esmc_dnus_sent

(Optional) esmc dnus sent

esmc_infos_rcvd

(Optional) esmc infos rcvd

esmc_events_rcvd

(Optional) esmc events rcvd

esmc_dnus_rcvd

(Optional) esmc dnus recvd

esmc_malformed_rcvd

(Optional) esmc malformed rcvd frames

esmc_rcvd_error

(Optional) esmc recv frame errors

esmc-end

(Optional) End of table

Command Mode

  • /exec

show esmc packet-trace

show esmc packet-trace [ __readonly__ <esmc-header> [ TABLE_esmc <intf-name> <sup-time> <pkt_dir> <pkt_type> <pkt_info> ] <esmc-end> ]

Syntax Description

show

Show running system information

esmc

Ethernet Synchronization Messaging Channel

__readonly__

(Optional) Read Only

packet-trace

Display last few packet traces

esmc-header

(Optional) start of table

TABLE_esmc

(Optional) ESMC table

intf-name

(Optional) interface name

sup-time

(Optional) sup time

pkt_dir

(Optional) packet direction

pkt_type

(Optional) packet type

pkt_info

(Optional) packet information

esmc-end

(Optional) end of table

Command Mode

  • /exec

show evb

show evb [ __readonly__ <evb_role> <evb_vdp_mac> [ <evb_cisco_mac> ] [ <evb_user_mac> ] <evb_rwd> <evb_rka> <evb_cnt_recv_vdpdu> <evb_cnt_drop_vdpdu> <evb_cnt_recv_tlv> <evb_cnt_recv_mgr_tlv> <evb_cnt_recv_assoc_tlv> <evb_cnt_recv_cmd> ]

Syntax Description

show

Show running system information

evb

EVB (Edge Virtual Bridge)

__readonly__

(Optional)

evb_role

(Optional) EVB role

evb_vdp_mac

(Optional) VDP Mac address

evb_cisco_mac

(Optional) Cisco Mac address

evb_user_mac

(Optional) User mac address

evb_rwd

(Optional) Resource wait init exponent

evb_rka

(Optional) Keep-alive init exponent

evb_cnt_recv_vdpdu

(Optional) No. received vdpdu

evb_cnt_drop_vdpdu

(Optional) No. dropped vdpdu

evb_cnt_recv_tlv

(Optional) No. received tlv

evb_cnt_recv_mgr_tlv

(Optional) No. received mgr tlv

evb_cnt_recv_assoc_tlv

(Optional) No. received assoc tlv

evb_cnt_recv_cmd

(Optional) No. received commands

Command Mode

  • /exec

show evb hosts

show evb hosts [ { summary | detail | internal-info } ] [ { [ mac <mac-addr> | interface <intf-name> | vlan <vlan-id> | vni <vni-id> | ip <ip-addr> | ipv6 <ipv6-addr> | name <host-name> ] + } ] [ __readonly__ <evb_cnt_host> <evb_cnt_assoc_vsi> [ { TABLE_evb_host <host_row_id> <host_name> [ <host_uuid> ] [ { TABLE_evb_vsi <vsi_row_id> <mgr_id> <vsi_id> [ <vsi_host_name> ] <interface> [ <vpc> ] [ <s_channel> ] [ <station_mac> ] [ <m_state> ] [ <e_state> ] [ <reason> ] [ <timer> ] [ <profile_id> ] [ { TABLE_evb_vsi_filter <filter_row_id> [ <filter_group> ] [ <filter_vid> ] [ <filter_bd> ] [ <filter_mac> ] [ <filter_ip> ] } ] } ] } ] ]

Syntax Description

show

Show running system information

evb

EVB (Edge Virtual Bridge)

hosts

Host information

summary

(Optional) Display summary information

detail

(Optional) Display detailed information

internal-info

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

mac

(Optional) Display hosts by MAC address

mac-addr

(Optional) MAC Address

interface

(Optional) Display hosts by interface

intf-name

(Optional) Interface name

vlan

(Optional) Display hosts by VLAN

vlan-id

(Optional) VLAN ID

vni

(Optional) Display hosts by Virtual Network Identifier

vni-id

(Optional) VNI

ip

(Optional) Display hosts by IP address

ipv6

(Optional) Display hosts by IPv6 address

ip-addr

(Optional) IP address

name

(Optional) Display hosts by host name

host-name

(Optional) Host name substring

__readonly__

(Optional)

evb_cnt_host

(Optional) No. host entries

evb_cnt_assoc_vsi

(Optional) No. associated VSI entires

TABLE_evb_host

(Optional) EVB host table

host_row_id

(Optional) Host row id

host_name

(Optional) Host name

host_uuid

(Optional) Host uuid

TABLE_evb_vsi

(Optional) EVB vsi table

vsi_row_id

(Optional) VSI row id

mgr_id

(Optional) Manager id

vsi_id

(Optional) VSI id

vsi_host_name

(Optional) Host name

interface

(Optional) Interface

vpc

(Optional) VPC

s_channel

(Optional) S-Channel

station_mac

(Optional) Station mac address

profile_id

(Optional) Profile id

m_state

(Optional) Machine state

e_state

(Optional) Entry state

reason

(Optional) State reaon

timer

(Optional) Countdown timer

TABLE_evb_vsi_filter

(Optional) EVB filter table

filter_row_id

(Optional) Filter row id

filter_group

(Optional) Group id

filter_vid

(Optional) Vlan id

filter_bd

(Optional) Bridge-domain id

filter_mac

(Optional) Mac address

filter_ip

(Optional) IP address

Command Mode

  • /exec

show evb vsi

show evb vsi [ { summary | detail | internal-info } ] [ { [ mac <mac-addr> | interface <intf-name> | vlan <vlan-id> | vni <vni-id> | ip <ip-addr> | ipv6 <ipv6-addr> ] + } ] [ __readonly__ <evb_cnt_vsi> <evb_cnt_assoc_vsi> [ { TABLE_evb_vsi <vsi_row_id> <mgr_id> <vsi_id> [ <vsi_host_name> ] <interface> [ <vpc> ] [ <s_channel> ] [ <station_mac> ] [ <m_state> ] [ <e_state> ] [ <reason> ] [ <timer> ] [ <profile_id> ] [ { TABLE_evb_vsi_filter <filter_row_id> [ <filter_group> ] [ <filter_vid> ] [ <filter_bd> ] [ <filter_mac> ] [ <filter_ip> ] } ] } ] ]

Syntax Description

show

Show running system information

evb

EVB (Edge Virtual Bridge)

vsi

Virtual Station Interface (VSI) information

summary

(Optional) Display summary information

detail

(Optional) Display detailed information

internal-info

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

mac

(Optional) Display VSI by MAC address

mac-addr

(Optional) MAC Address

interface

(Optional) Display VSI by interface

intf-name

(Optional) Interface name

vlan

(Optional) Display VSI by VLAN

vlan-id

(Optional) VLAN ID

vni

(Optional) Display VSI by Virtual Network Identifier

vni-id

(Optional) VNI

ip

(Optional) Display VSI by IP address

ipv6

(Optional) Display VSI by IPv6 address

ip-addr

(Optional) IP address

__readonly__

(Optional)

evb_cnt_vsi

(Optional) No. VSI entries

evb_cnt_assoc_vsi

(Optional) No. associated VSI entires

TABLE_evb_vsi

(Optional) EVB vsi table

vsi_row_id

(Optional) VSI row id

mgr_id

(Optional) Manager id

vsi_id

(Optional) VSI id

vsi_host_name

(Optional) Host name

interface

(Optional) Interface

vpc

(Optional) VPC

s_channel

(Optional) S-Channel

station_mac

(Optional) Station mac address

profile_id

(Optional) Profile id

m_state

(Optional) Machine state

e_state

(Optional) Entry state

reason

(Optional) State reaon

timer

(Optional) Countdown timer

TABLE_evb_vsi_filter

(Optional) EVB filter table

filter_row_id

(Optional) Filter row id

filter_group

(Optional) Group id

filter_vid

(Optional) Vlan id

filter_bd

(Optional) Bridge-domain id

filter_mac

(Optional) Mac address

filter_ip

(Optional) IP address

Command Mode

  • /exec

show event manager environment

show event manager environment { all | <varname> } [ __readonly__ <environment-details> ]

Syntax Description

show

Show running system information

event

Event Manager commands

manager

Event Manager commands

environment

Show information about environment variables

all

Show information about all the configured environment variables

varname

The environment variable name on which information is required

__readonly__

(Optional)

environment-details

(Optional) Show information about environment variables

Command Mode

  • /exec

show event manager event-types

show event manager event-types [ all | <event-type-name> ] [ module <module-id> ] [ __readonly__ { <event-types> } ]

Syntax Description

show

Show running system information

event

Event Manager commands

manager

Event Manager commands

event-types

Show information about registered event types

all

(Optional) Show information about advanced event types as well

event-type-name

(Optional) Show information about the specified event type

module

(Optional) Show information about event types on other modules

module-id

(Optional) Module Id

__readonly__

(Optional)

event-types

(Optional) Show information about registered event types

Command Mode

  • /exec

show event manager events action-log

show event manager events action-log [ policy <policy-name> | event-type <event-type-name> ] [ __readonly__ { <action-log-data> } ]

Syntax Description

show

Show running system information

event

Event Manager commands

manager

Event Manager commands

events

Show information about the history of past events

action-log

Show policy action logs

policy

(Optional) Name of policy

policy-name

(Optional) Enter policy name

event-type

(Optional) Name of event

event-type-name

(Optional) Enter event type

__readonly__

(Optional)

action-log-data

(Optional) Show information about the policy action logs

Command Mode

  • /exec

show event manager history events

show event manager history events [ detail ] [ maximum <n-events> ] [ severity <sev> ] [ __readonly__ { <history-events> } ]

Syntax Description

show

Show running system information

event

Event Manager commands

manager

Event Manager commands

history

Show information about the history of past activity

events

Show information about the history of past events

detail

(Optional) Show information about the event parameters as well

maximum

(Optional) Specify an upper limit on the number of events to be shown

n-events

(Optional) Specify the maximum number of events to be shown

severity

(Optional) Show only those events whose severity is >= specified severity

sev

(Optional) Enter the severity threshold

__readonly__

(Optional)

history-events

(Optional) Show information about the history of past events

Command Mode

  • /exec

show event manager policy-state

show event manager policy-state <name> [ module <module-id> ] [ __readonly__ { <policy-state> } ]

Syntax Description

show

Show running system information

event

Event Manager commands

manager

Event Manager commands

policy-state

Show information about the state of a policy

name

Name of the policy

module

(Optional) Get the information from a module

module-id

(Optional) Module Id

__readonly__

(Optional)

policy-state

(Optional) Show information about the state of a policy

Command Mode

  • /exec

show event manager script system

show event manager script system { all | <script-name> } [ __readonly__ <script_system_details> ]

Syntax Description

show

Show running system information

event

Event Manager commands

manager

Event Manager commands

script

Show information about a script policy

system

Show information about a system script policy

all

Show all the available system script policies

script-name

Name of the system script policy

__readonly__

(Optional)

script_system_details

(Optional) Show Information about system script policies

Command Mode

  • /exec

show event manager system-policy

show event manager system-policy [ all | <policy-name> ] [ __readonly__ { [ TABLE_eem [ <thresh_min> ] [ <thresh_max> ] <event_name> <event_description> <event_overridable> <event_type> ] } ]

Syntax Description

show

Show running system information

event

Event Manager commands

manager

Event Manager commands

system-policy

Show information about default system policies

all

(Optional) Show all policies (including advanced and non-overridable ones)

policy-name

(Optional) Show detailed information about the specified policy

__readonly__

(Optional)

TABLE_eem

(Optional)

thresh_min

(Optional)

thresh_max

(Optional)

event_name

(Optional)

event_description

(Optional)

event_overridable

(Optional)

event_type

(Optional)

Command Mode

  • /exec