New and Changed Information
Feature |
Description |
Changed in Release |
Where Documented |
---|---|---|---|
VXLAN with IPv6 Underlay |
IPv6 Underlay is supported on N9K-X9716D-GX, N9K-X97160YC-EX, N9K-X9736C-FX with N9K-C9508-FM-E2, and N9K-X97160YC-EX, N9K-X97160YC-EX with N9K-C9508-FM-E fabric modules. |
10.2(3)F |
Guidelines and Limitations for VXLAN with IPv6 in the Underlay (VXLANv6) |
Port Multi-VLAN |
The Port Multi-VLAN feature is supported on N9KC9316D-GX, N9K-C93600CD-GX, N9K-C9364C-GX, and Cisco Nexus 9300 GX2 switches. |
10.2(3)F |
|
VXLAN PBR |
The VXLAN PBR feature is supported with VXLANv6 on all TOR switches. |
10.2(3)F |
|
NVE Interface Fabric Readiness Timer |
Configuring the NVE interface fabric readiness timer allows BGP to delay the fabric route advertisement to VRF peers and VRF peer routes to fabric so that there are no transient traffic drops seen when border leaf nodes come up after a switch reload. |
10.2(3)F |
|
Migrating from FabricPath to VXLAN |
NX-OS allows you to migrate workloads from an existing FabricPath network to a new VXLAN BGP EVPN network with minimal traffic impact and coexistence of both DAG and HSRP gateway. |
10.2(3)F |
|
VXLAN OAM |
You do not have to enable the VXLAN feature for configuring the NGOAM feature on intermediate nodes. |
10.2(3)F |
|
VXLAN and GRE co-existence |
Added support on Cisco Nexus 9300-EX/FX/FX2/FX3/GX/GX2 switches. |
10.2(3)F |
|
VXLAN with IPv6 Underlay |
Added support on Cisco Nexus 9300- EX, GX EOR switches. |
10.2(3)F |
Guidelines and Limitations for VXLAN with IPv6 in the Underlay (VXLANv6) |
EVPN multi-homing inter-operability |
Enhanced the support for vPC-based multihoming, where a pair of switches act as a single device for redundancy and both switches function in an active mode. |
10.2(2)F |
Interoperability with EVPN Multi-Homing Using ESI for Multi-Site Anycast BGW |
MLAG BGW support for Cloudsec |
Enhanced multihoming on Cloudsec BGWs for vPC support. |
10.2(2)F |
|
Firewall Clustering with VXLAN EVPN |
Configures a firewall cluster that spans across multiple sites running a VXLAN fabric with a BGP EVPN control plane. |
10.2(2)F |
|
VXLAN Scale Enhancements |
Enhanced the scale limits for Layer 2 VNIs, Extended Layer 2 VNIs, Layer 3 VNIs, SVI with Distributed Anycast Gateway. Enhanced the scale limits for IPv4 and IPv6 host routes in internet-peering mode and the ECMP paths. |
10.2(2)F |
|
VXLAN TRM |
Added support for VXLAN TRM on Cisco Nexus N9KC9332D-GX2B platform switches. |
10.2(1q)F |
|
VXLAN EVPN |
Added support for VXLAN EVPN on Cisco Nexus N9KC9332D-GX2B platform switches. |
10.2(1q)F |
|
EVPN Hybrid IRB Mode |
Introduced support for EVPN Hybrid IRB mode. |
10.2(1)F |
|
EVPN Distributed NAT |
Enables NAT on the leaf and spine in the VXLAN topology. |
10.2(1)F |
|
Tenant Routed Multicast (TRM) with IPv6 Overlay |
Added support for TRM IPv6 in the overlay. |
10.2(1)F |
|
Tenant Routed Multicast (TRM) with vPC BGW and with Anycast BGW |
Added support on Cisco Nexus 9300-GX family switches. |
10.2(1)F |