If at least one sFlow data source is configured, the SPAN sessions cannot be brought up.
-
If at least one SPAN session is configured as
no shut
, sFlow data sources cannot be added.
-
The sampling mode that is used for sFlow is based on an algorithm that is known as LFSR. Due to the use of LFSR, it is not
guaranteed that one in every few packets are sampled with the sampling rate of n. However, the number of packets that are
sampled is equal to the total packets over a period of time.
-
When sFlow is used to sample the Rx traffic from FEX HIF ports, additional VNTAG and 802.1q tags are present in the sampled
traffic.
-
In Cisco Nexus 9300-EX and 9300-FX platform switches, the FEX, HIF, and NIF ports cannot be configured as sFlow data-source
interfaces.
-
When sFlow and SPAN are configured on the same interface, and the hardware rate-limiter is configured for sFlow, the Rate-Limiter
Drops counter in the output of the show hardware rate-limiter command displays more drops than expected.
-
sFlow is a software-driven feature, hardware only sends copies of traffic from the sFlow source interfaces to the CPU for
further processing. Elevated CPU usage is expected. sFlow traffic sent to the CPU by hardware is rate-limited to protect the
CPU.
-
When you enable sFlow for an interface, it is enabled for both ingress and egress. You cannot enable sFlow for only ingress
or only egress.
For Cisco Nexus 9508 switches with Cisco Nexus 9636C-R and 9636Q-R line cards, sFlow can be enabled for an interface only
in the ingress direction.
-
The storm control feature does not work if you enable storm control on an interface where sFlow is also enabled.
-
sFlow is not supported on the SVIs.
-
Subinterfaces are not supported for sFlow.
-
We recommend you configure the sampling rate that is based on the sFlow configuration and traffic in the system.
-
The switch supports only one sFlow collector.
-
sFlow and Network Address Translation (NAT) are not supported on the same port.
-
sFlow supports sampling IPv6 traffic.
-
sFlow does not support egress sampling for multicast, broadcast, or unknown unicast packets.
-
sFlow counters increment even for control packets that ingress on the sFlow data-source interfaces. These packets may be sampled
and send out as sFlow datagrams (similar to data plane traffic).
-
The following Cisco Nexus switches support sFlow and SPAN together:
-
N9336C-FX2
-
N93240YC-FX2
-
N93360YC-FX2
-
Beginning with Cisco NX-OS Release 9.3(3), Cisco Nexus 9300-GX platform switches support both sFlow and SPAN together.
-
Nexus 9000-EX, FX, GX family of switches only support sampling at the following values: 4096, 8192, 16384, 32768, 65536. Configuring
values other than these results in the value being rounded off to the next supported value.
-
When sFlow is configured on N9K-C9508-FM-G with the N9K-X9716D-GX line card, disable sFlow before configuring SPAN sessions.
-
Beginning with Cisco NX-OS Release 10.1(1), sFlow and SPAN are supported on Cisco N9K-C93180YC-FX3 platform switches.
-
Beginning with Cisco NX-OS Release 10.1(2), sFlow is supported on the Cisco Nexus N9K-X9624D-R2 line card.
-
Beginning with Cisco NX-OS Release 10.1(2), sFlow supports VXLAN traffic on the Cisco Nexus N9K-C9508-FM-G cloud-scale fabric
module with the N9K-X9716D-GX line card.
-
Beginning with Cisco NX-OS Release 10.2(1), sFlow Extended BGP (Gateway) is supported on the Cisco Nexus N9K-C93600CD-GX,
N9K-C93240YC-FX2, N9K-C93180YC-EX, N9K-C93180YC-FX, N9K-C93180YC-FX3S, N9K-93600CD-GX, and N9K-X9716D-GX platform switches.
-
NX-OS provides flexible forwarding templates to utilize the hardware resources according to customer needs. For sFlow ingress
IPv6 sampling to fill BGP information correctly in the sFlow record, a template which has all IPv6 routes on the line-card
has to be selected. For example, customers can configure system routing template-mpls-heavy. For more information, please refer to the Cisco Nexus 9000 Series NX-OS Command Reference (Configuration Commands), Release
9.3(x). For command to take effect, system needs to be rebooted. This is applicable on GX modular chassis.
-
When ECMP is configured in BGP and in case of ECMP destination routes, the next-hop information in the extended gateway record
of the exported sFlow record will be 0. Other BGP information like Autonomous System will be derived from the first path.
The output interface in the sFlow record will be set to 0 (unknown) to indicate that the flow could be through any of the
paths.
-
Beginning with Cisco NX-OS Release 10.2(1q)F, sFlow is supported on the Cisco N9K-C9332D-GX2B platform switches.
-
Beginning with Cisco NX-OS Release 10.2(1), extended BGP data can now be collected. In order for sFlow to collect this data,
a non-SVI Layer 3 interface such as a physical interface or port-channel must be configured as the sFlow source.
-
Beginning with Cisco NX-OS Release 10.2(3)F, sFlow flow-cache size is increased from 3k route entries in earlier releases
to 30k v4 and 30k v6 route entries. This feature is supported on Cisco Nexus C93600CD-GX, C93240YC-FX2, C93180YC-EX, C93180YC-FX,
C93180YC-FX3S, 93600CD-GX, and X9716D-GX platform switches.
-
Beginning with Cisco NX-OS Release 10.3(1)F, sFlow is supported on the Cisco Nexus 9808 platform switches.
-
For egress sampled packet, re-written information is not available in sFlow record.
-
Egress sFlow is not supported for directly connected host.
-
sFlow is not supported on the sub-interface traffic.
-
Beginning with Cisco NX-OS Release 10.3(1)F, sFlow supports IPv6 collector. However, at a time, only one collector can be
configured, either IPv4 or IPv6. Also, the source ip address and the collector ip address must belong to the same address
family, that is, either IPv4 or IPv6 address family.