Node Specifications

This appendix lists the technical specifications for the node and includes the following sections:

Physical Specifications

Table A-1 lists the physical specifications for the node.

Table A-1 Physical Specifications

Description
Specification

Height

3.4 in. (8.70 cm)

Width (including slam latches)

19.0 in. (48.26 cm)

Depth (length)

Depth, including slam latches and power supply handles

29.0 in. (73.70 cm)

31.5 in. (80.00 cm)

Maximum Weight (fully loaded)

62.7 lb. (28.4 Kg)

Power Specifications

The power specifications for the four power supply options are listed in the following sections:

You can get more specific power information for your exact node configuration by using the Cisco UCS Power Calculator:

http://ucspowercalc.cisco.com

650 W AC Power Supply

Table A-2 lists the specifications for each 650 W AC power supply
(Cisco part number UCSC-PSU2V2-650W=).

 

Table A-2 Power Supply Specifications

Description
Specification

AC input voltage

Nominal range: 100–120 VAC, 200–240 VAC

(Range: 90–132 VAC, 180–264 VAC)

AC input frequency

Nominal range: 50 to 60Hz

(Range: 47–63 Hz)

Maximum AC input current

7.6 A at 100 VAC

3.65 A at 208 VAC

Maximum input volt-amperes

760 VA at 100 VAC

Maximum output power per PSU

650 W

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

12 ms at 650 W

Power supply output voltage

12 VDC

Power supply standby voltage

3.3 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP1

Input connector

IEC320 C14

1200 W AC Power Supply

Table A-3 lists the specifications for each 1200 W AC power supply
(Cisco part number UCSC-PSU2V2-1200W=).

 

Table A-3 Power Supply Specifications

Description
Specification

AC input voltage

Nominal range: 100–120 VAC, 200–240 VAC

(Range: 90–132 VAC, 180–264 VAC)

AC input frequency

Nominal range: 50 to 60Hz

(Range: 47–63 Hz)

Maximum AC input current

11 A at 100 VAC

7 A at 200 VAC

Maximum input volt-amperes

1456 VA

Maximum output power per PSU

800 W at 100–120 VAC

1200 W at 200–240 VAC

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

12 ms at 1200 W

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP1

Input connector

IEC320 C14

1400 W AC Power Supply

Table A-4 lists the specifications for each 1400 W AC power supply
(Cisco part number UCSC-PSU2-1400=).

 

Table A-4 1400 W Power Supply Specifications

Description
Specification

AC input voltage

Nominal range: 200–240 VAC

(Range: 180–264 VAC)

AC input frequency

Nominal range: 50 to 60Hz

(Range: 47–63 Hz)

Maximum AC input current

8.5 A at 200 VAC

Maximum input volt-amperes

1700 VA

Maximum output power per PSU

1400 W at 200–240 VAC

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

12 ms at 1200 W

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP1

Input connector

IEC320 C14

930 W DC (Version 1) Power Supply, UCSC-PSU-930WDC

Table A-5 lists the specifications for each 930 W DC power supply
(Cisco part number UCSC-PSU-930WDC=).

 

Table A-5 930 W DC Power Supply Specifications

Description
Specification

DC input voltage range

Nominal range: –48 to –60 VDC nominal

(Range: –40 to –60 VDC)

Maximum DC input current

23 A at –48 VDC

Maximum input W

1104 W

Maximum output power per PSU

930 W

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

8 ms at 930 W

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

> 92% at 50% load

Form factor

RSP1 (2U and 4U systems)

Input connector

Removable connector block UCSC-CONN-930WDC=

Environmental Specifications

Table A-6 lists the environmental specifications for the node.

 

Table A-6 Environmental Specifications

Description
Specification

Temperature, operating

41 to 95°F (5 to 35°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above sea level.

Temperature, nonoperating

(when the node is in storage or is transported)

–40 to 149°F (–40 to 65°C)

Humidity (RH), operating

10 to 90%

Humidity, non-operating

5 to 93%

Altitude, operating

0 to 10,000 feet

Altitude, nonoperating

(when the node is in storage or is transported)

0 to 40,000 feet

Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)

5.8

Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)

43