The recovery upgrade procedure can only be performed on a SPA that has been powered off by the system after it has failed
all of the retries attempted to initialize the SPA.
The following example displays the output of an attempt to perform a recovery upgrade before all the initialization retries
have been attempted for the SPA in subslot 0/1.
Note |
Because a recovery upgrade is done at a more conservative speed, it may take more than the estimated upgrade time.
|
Note |
Other factors can cause the system to ask “Do you want to perform the recovery upgrade operation?” Only answer y to this question if you have attempted an FPD upgrade that has failed due to a power failure or a SPA removal.If you are
prompted for this question without having previously had a failed upgrade attempt for one of the aforementioned reasons, contact
Cisco Technical Support.
|
Nov.28 11:29:55:%SPA_OIR-3-RECOVERY_RELOAD:subslot 0/1:Attempting
recovery by reloading SPA
Nov.28 11:30:10:%SPA_OIR-3-HW_INIT_TIMEOUT:subslot 0/1
Nov.28 11:30:15:%SPA_OIR-3-RECOVERY_RELOAD:subslot 0/1:Attempting
recovery by reloading SPA
Nov.28 11:30:31:%SPA_OIR-3-HW_INIT_TIMEOUT:subslot 0/1
Router# upgrade hw-module subslot 0/1 fpg bundled
% Cannot get FPD version information for version checking. If a previous
upgrade attempt has failed for the target card, then a recovery upgrade
would be required to fix the failure.
% The following FPD(s) will be upgraded for SPA-4XOC3-POS (H/W ver =
1.0) in subslot 0/1:
================== =========== =========== ============
Field Programmable Current Upgrade Estimated
Device:"ID-Name" Version Version Upgrade Time
================== =========== =========== ============
1-I/O FPGA ?.? 3.4 00:00:50
================== =========== =========== ============
% Do you want to perform the recovery upgrade operation? [no]:y
% Cannot perform recovery upgrade operation because the target card is
not in a failed state. Please try again later.
Once the following error message is displayed, you can perform the recovery upgrade:
Nov.28 11:31:31:%SPA_OIR-3-SPA_POWERED_OFF:subslot 0/1:SPA 4xOC3 POS SPA powered off after 5 failures within 600 seconds
Note |
You must wait to see this error message before you attempt the upgrade.
|
Perform the manual FPD image upgrade method using the upgrade hw-module subslot command to recover from a corrupted image after the SPA has been powered off by the system. In this command, slot-number
is the slot where the SIP is installed, subslot-number
is the subslot of the SIP where the SPA is located.
The following example displays the console output of a recovery upgrade operation:
Router# upgrade hw-module subslot 0/1 fpd bundled
% Cannot get FPD version information from SPA-4XOC3-POS in subslot 0/1.
If a previous upgrade attempt on the target card was interrupted, then the
corruption of FPD image might have prevented the card from coming online.
If this is the case, then a recovery upgrade would be required to fix the
failure.
(Hit ENTER to proceed with recovery upgrade operation) [confirm]
% The following FPD will be upgraded for SPA-4XOC3-POS (H/W ver = 1.0) in subslot 0/1:
================== =========== =========== ============
Field Programmable Current Upgrade Estimated
Device: "ID-Name" Version Version Upgrade Time
================== =========== =========== ============
1-I/O FPGA ?.? 3.4 00:00:50
================== =========== =========== ============
% NOTES:
- Use 'show upgrade fpd progress' command to view the progress of the FPD
upgrade.
- Since the target card is currently in disabled state, it will be
automatically reloaded after the upgrade operation for the changes to
take effect.
% Do you want to perform the recovery upgrade operation? [no]: y
% Starting recovery upgrade operation in the background ...
(Use "show upgrade fpd progress" command to see upgrade progress)
Router#
*Nov 28 17:46:10.191:%FPD_MGMT-6-UPGRADE_TIME: Estimated total FPD image upgrade time for SPA-4XOC3-POS card in subslot 0/1 = 00:00:50.
*Nov 28 17:46:10.233:%FPD_MGMT-6-UPGRADE_START: I/O FPGA (FPD ID=1) image upgrade in progress for SPA-4XOC3-POS card in subslot 0/1. Updating to version 3.4. PLEASE DO NOT INTERRUPT DURING THE UPGRADE PROCESS (estimated upgrade completion time = 00:00:50) ...
*Nov 28 17:46:55.948:%FPD_MGMT-6-UPGRADE_PASSED: I/O FPGA (FPD ID=1) image in the SPA-4XOC3-POS card in subslot 0/1 has been successfully updated from version ?.? to version 3.4. Upgrading time = 00:00:45.715
*Nov 28 17:46:55.948:%FPD_MGMT-6-OVERALL_UPGRADE: All the attempts to upgrade the required FPD images have been completed for SPA-4XOC3-POS card in subslot 0/1. Number of successful/failure upgrade(s): 1/0.
*Nov 28 17:46:55.949:%FPD_MGMT-5-CARD_POWER_CYCLE: SPA-4XOC3-POS card in subslot 0/1 is being power cycled for the FPD image upgrade to take effect.