Limitations and Compatible Characteristics of Ethernet Link Bundles
This list describes the properties and limitations of ethernet link bundles:
-
Any type of Ethernet interfaces can be bundled, with or without the use of LACP (Link Aggregation Control Protocol).
-
A single router can support a maximum of 256 bundle interfaces. Link bundles of only physical interfaces are supported.
-
Physical layer and link layer configuration are performed on individual member links of a bundle.
-
Configuration of network layer protocols and higher layer applications is performed on the bundle itself.
-
IPv4 and IPv6 addressing is supported on ethernet link bundles.
-
A bundle can be administratively enabled or disabled.
-
Each individual link within a bundle can be administratively enabled or disabled.
-
Ethernet link bundles are created in the same way as Ethernet channels, where the user enters the same configuration on both end systems.
-
The MAC address that is set on the bundle becomes the MAC address of the links within that bundle.
-
Load balancing (the distribution of data between member links) is done by flow instead of by packet. Data is distributed to a link in proportion to the bandwidth of the link in relation to its bundle.
-
QoS is supported and is applied proportionally on each bundle member.
-
All links within a single bundle must terminate on the same two systems.
-
Bundled interfaces are point-to-point.
-
A link must be in the up state before it can be in distributing state in a bundle.
-
Only physical links can be bundle members.
-
Multicast traffic is load balanced over the members of a bundle. For a given flow, internal processes select the member link and all traffic for that flow is sent over that member.