Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


The error dialog box in Figure 4-1 consists of three parts: the error title, error ID, and the error message.

Figure 4-1 Error Dialog Box

Table 4-1 Error Messages 

Error ID
Error Message
Description

EID-0000

Invalid Error ID.

The error ID is invalid.

EID-0001

Null pointer encountered in {0}.

Cisco Transport Controller (CTC) encountered a null pointer in the area described by the specified item.

EID-1000

The host name of the network element cannot be resolved to an address.

Refer to error message text.

EID-1001

Unable to launch CTC due to applet security restrictions. Please review the installation instructions to make sure that the CTC launcher is given the permissions it needs. Note that you must exit and re-start your browser in order for the new permissions to take effect.

Refer to error message text.

EID-1002

The host name (e.g., for the network element) was successfully resolved to its address, but no route can be found through the network to reach the address.

Refer to error message text.

EID-1003

General exception. {0}

Unexpected exception/error while launching CTC from the applet.

Failed to rollback card provisioning while cancelling a span upgrade.

Unexpected error while assigning east or west protect port of a bidirectional line switched ring (BLSR).

EID-1004

Problem Deleting CTC Cache:
{0}
{1}

CTC encountered a problem deleting the cache.

EID-1005

IOException writing batch file to launch CTC.

CTC could not write the launching batch file.

EID-1006

Malformed URL trying to download LAUNCHER.jar.

The URL used to download the Launcher.jar file is malformed.

EID-1007

IO Exception trying to download LAUNCHER.jar.

An input/output exception was encountered when CTC tried to download the GUI launcher.

EID-1008

Malformed URL trying to download ORB.

The URL used to download the ORB.jar file is malformed.

EID-1009

IO Exception trying to download ORB.

There was a problem trying to download the ORB.jar file. It has not been downloaded.

EID-1010

Alias Exists.

The alias already exists.

EID-1011

KeyStoreException

CTC encountered a keystore exception trying to complete this task.

EID-1012

Can not find file. FileNotFoundException

The file could not be found.

EID-1013

IOException

CTC encountered an input/output exception.

EID-1014

NoSuchAlgortihmException

The algorithm does not exist.

EID-1015

CertificateException

CTC encountered a certificate exception.

EID-1016

Null Keystore

CTC encountered a null keystore while trying to complete this task.

EID-1017

The policy file was not changed due to an error writing the {0} file.

The policy file was not changed due to an error writing the specified file.

EID-1018

Password must contain at least 1 alphabetic, 1 numeric, and 1 special character (+, # or %).

Password shall not contain the associated user-ID

The password is invalid.

EID-1019

Could not create {0}.

Please enter another filename to save file as.

CTC could not create the file due to an invalid filename.

EID-1020

Fatal exception occurred, exiting CTC.

Unable to switch to the Network view.

CTC was unable to switch from the node or card view to the network view, and is now shutting down.

EID-1021

Unable to navigate to {0}.

Failed to display the indicated view—node or network.

EID-1022

A session cannot be opened right now with this slot. Most likely someone else (using a different CTC) already has a session opened with this slot.

Please try again later.

Refer to error message text.

EID-1023

This session has been terminated. This can happen if the card resets, the session has timed out, or if someone else (possibly using a different CTC) already has a session open with this slot.

Refer to error message text.

EID-1024

Error writing to {0}.

An error occurred while exporting an HTML report.

EID-1025

Unable to create Help Broker

CTC was unable to create the help broker for the online help.

EID-1026

Unable to locate HelpSet.

CTC was unable to locate the help set for the online help.

EID-1027

Unable to locate Help ID: {0}

CTC was unable to locate the help ID for the online help.

EID-1028

Error saving table {0}.

There was an error saving the specified table.

EID-1029

Malformed URL trying to download {0}.jar.

The URL used to download the JavaHelp JAR file is malformed.

EID-1030

IO Exception trying to download {0}.jar.

An input/output error occurred while CTC was downloading the specified JAR file.

EID-2001

No rolls selected.

No rolls were selected for the bridge and roll.

EID-2002

The Roll must be completed or cancelled before it can be deleted.

You cannot delete the roll unless it has been completed or cancelled.

EID-2003

Error deleting roll.

There was an error when CTC tried to delete the roll.

EID-2004

No IOS slot selected.

You did not select a Cisco IOS slot.

EID-2005

CTC cannot find the online help files for {0}. The files may have been moved, deleted, or not installed. To install online help, run the setup program on the software or documentation CDs.

CTC cannot find the online help files for the specified window. The files might have been moved, deleted, or not installed. To install online help, run the setup program on the software or documentation CDs.

EID-2006

Error editing circuit(s).
{0}
{1}.

An error occurred when CTC tried to open the circuit for editing.

EID-2007

Unable to save preferences.

CTC cannot save the preferences.

EID-2008

Unable to store circuit preferences. File not found.

CTC cannot find the file needed to save the circuit preferences.

EID-2009

Unable to store circuit preferences. I/O error.

An input/output error is preventing CTC from saving the circuit preferences.

EID-2010

Delete destination failed.

CTC could not delete the destination.

EID-2011

Circuit destroy failed.

CTC could not destroy the circuit.

EID-2012

Reverse circuit destroy failed.

CTC could not reverse the circuit destroy.

EID-2013

Circuit creation error. Circuit creation cannot proceed due to changes in the network which affected the circuit(s) being created. The dialog will close. Please try again.

Refer to error message text.

EID-2014

No circuit(s) selected.

You must select a circuit to complete this function.

EID-2015

Cannot delete circuit.
{0}

CTC cannot delete the circuit.

EID-2016

Circuit deletion error.

There was an error deleting the circuit.

EID-2017

Error mapping circuit.
{0}

There was an error mapping the circuit.

EID-2018

Circuit roll failure. The circuit has to be in the ACTIVE state in order to perform a roll.

Refer to error message text.

EID-2019

Circuit roll failure. The current version does not support bridge and roll on a VT tunnel.

Refer to error message text.

EID-2020

Circuit roll failure. The two circuits must have the same direction.

Refer to error message text.

EID-2021

Circuit roll failure. The two circuits must have the same size.

Refer to error message text.

EID-2022

Circuit roll failure. A maximum of two circuits can be selected for a bridge and roll operation.

Refer to error message text.

EID-2023

Error deleting circuit.
{0}

There was an error deleting the circuit.

EID-2024

Node selection error.

There was an error during node selection.

EID-2025

This feature cannot be used. Verify that each of the endpoints of this circuit are running software that supports this feature.

This error is generated from the AnsOpticsParamsPane to indicate that the selected ring type is not supported by the endpoints of the circuit. In the VLAN pane it indicates that the backend spanning tree protocol (STP) disabling is not supported.

EID-2026

Request failed.
{0}

Error occurred while attempting to switch a path protection circuit away from a span.

EID-2027

Error deleting circuit drop.

CTC could not delete the circuit drop.

EID-2028

Error removing circuit node.

CTC could not remove the circuit node.

EID-2029

The requested operation is not supported.

The task you are trying to complete is not supported by CTC.

EID-2030

Provisioning error.

There was an error during provisioning.

EID-2031

Error adding node.

There was an error while adding a node.

EID-2032

Error renaming circuit.
{0}

CTC could not rename the circuit.

EID-2033

Cannot verify table data.
{0}
{1}

There was an internal error while validating the user changes during Apply. This error can occur in the Edit Circuit dialog box or in the BLSR table in the shelf view (rare condition).

EID-2034

Cannot verify table data.
{0}

There was an internal error while validating the user changes during Apply. This error occurs in the Edit Circuit dialog box.

EID-2035

The source and destination nodes are not connected.

Refer to error message text.

EID-2036

Error deleting circuit drop.

There was an error deleting the circuit drop.

EID-2037

Application error. Cannot find attribute for {0}.

CTC cannot find an attribute for the specified item.

EID-2038

Invalid protection operation.

There was an invalid protection operation.

EID-2039

Internal communication error.

CTC experienced an internal communication error.

EID-2040

Please select a node first.

You must select a node before performing the task.

EID-2041

No paths are available on this link. Please make another selection.

Refer to error message text.

EID-2042

This span is not selectable. Only the green spans with an arrow may be selected.

Refer to error message text.

EID-2043

This node is not selectable. Only the source node and nodes attached to included spans (blue) are selectable. Selecting a selectable node will enable its available outgoing spans.

Refer to error message text.

EID-2044

This link may not be included in the required list. Constraints only apply to the primary path.

Refer to error message text.

EID-2045

This link may not be included in the required list. Only one outgoing link may be included for each node.

Refer to error message text.

EID-2046

No paths are available on this link. Please make another selection.

Refer to error message text.

EID-2047

Error validating slot number. Please enter a valid value for the slot number.

Refer to error message text.

EID-2048

Error validating port number. Please enter a valid value for the port number.

Refer to error message text.

EID-2049

Delete destination failed.

CTC could not delete the destination.

EID-2050

New circuit destroy failed.

CTC could not destroy the new circuit.

EID-2051

Circuit cannot be downgraded.
{0}

The specified circuit cannot be downgraded.

EID-2052

Error during circuit processing.

There was an error during the circuit processing.

EID-2053

No rolls selected.
{0}

You did not select a roll for this task.

EID-2054

Endpoint selection error.

There was an error during the endpoint selection.

EID-2055

No endpoints are available for this selection. Please make another selection.

This error occurs in the circuit creation dialog only during a race conditionthat has incorrectly allowed entities without endpoints to be displayed in the combo boxes.

EID-2056

Communication error.

An internal error occurred while synchronizing alarms with the nodes. Network Alarm pane.

EID-2058

Node deletion error.
{0}

There was an error during the node deletion.

EID-2059

Node deletion Error.
{0}

There was an error during the node deletion.

EID-2060

No PCA circuits found.

CTC could not find any protection channel access (PCA) circuits for this task.

EID-2061

Error defining VLAN.

There was an error defining the VLAN.

EID-2062

Cannot delete VLAN. No VLAN(s) are selected. Please select a VLAN.

Cannot delete VLAN. No VLAN(s) are selected. Please select a VLAN.

EID-2063

Cannot delete default VLAN.

The selected VLAN is the default VLAN, and cannot be deleted.

EID-2064

Error deleting VLANs.
{0}

There was an error deleting the VLAN.

EID-2065

Cannot import profile. Profile "{0}" exists in the editor and the maximum number of copies (ten) exists in the editor. Aborting the import. The profile has already been loaded eleven times.

Cannot import profile. The specified profile exists in the editor and the maximum number of copies (ten) exists in the editor. Aborting the import. The profile has already been loaded eleven times.

EID-2066

Unable to store profile. Error writing to {0}.

CTC encountered an error while trying to store the profile.

EID-2067

File write error.
{0}

CTC encountered a file write error.

EID-2068

ProvAlarmsPanedoImportNode error.

CTC encountered a ProvAlarmsPanedoImportNode error.

EID-2069

File not found or I/O exception.
{0}

Either the file was not found, or there was an input/output exception.

EID-2070

Failure deleting profile.
{0}

The profile deletion failed.

EID-2071

Only one column may be highlighted.

Refer to error message text.

EID-2072

Only one profile may be highlighted.

Refer to error message text.

EID-2073

This column is permanent and may not be removed.

Refer to error message text.

EID-2074

Select one or more profiles.

Refer to error message text.

EID-2075

This column is permanent and may not be reset.

Refer to error message text.

EID-2076

Error in reset refresh.
{0}

CTC encountered an error during the view reset/refresh.

EID-2077

This column is permanent and may not be renamed.

Refer to error message text.

EID-2078

At least two columns must be highlighted.

Refer to error message text.

EID-2079

Cannot load alarmables into table. There are no reachable nodes from which the list of alarmables may be loaded. Please wait until such a node is reachable and try again.

Refer to error message text.

EID-2080

Node {0} does not have deletable profiles.

The specified node does not have any deletable profiles.

EID-2081

Error removing profile {0} from node {1}.

There was an error removing the specified profile from the node.

EID-2082

Cannot find profile {0} on node {1}.

CTC cannot find the specified profile from the specified node.

EID-2083

Error adding profile {0} to node {1}.

There was an error adding the specified profile to the specified node.

EID-2084

Node {0} has no profiles.

The specified node has no profiles.

EID-2085

Invalid profile selection. No profiles were selected.

Refer to error message text.

EID-2086

Invalid node selection. No nodes were selected.

Refer to error message text.

EID-2087

No profiles were selected. Please select at least one profile.

Refer to error message text.

EID-2088

Invalid profile name.

Refer to error message text.

EID-2089

Too many copies of {0} exist. Please choose another name.

Too many copies of the specified item exist.

EID-2090

No nodes selected. Please select the node(s) on which to store the profile(s).

Refer to error message text.

EID-2091

Unable to switch to node {0}.

CTC is unable to switch to the specified node.

EID-2092

General exception error.

CTC encountered a general exception error while trying to complete the task.

EID-2093

Not enough characters in name.
{0}

There are not enough characters in the name.

EID-2094

Password and confirmed password fields do not match.

You must make sure the two fields have the same password.

EID-2095

Illegal password.
{0}

The password you entered is not allowed.

EID-2096

The user must have a security level.

You must have an assigned security level to perform this task.

EID-2097

No user name specified.

You did not specify a user name.

EID-2098

Ring switching error.

There was an error during the ring switch.

EID-2099

Ring switching error.

There was an error during the ring switch.

EID-2100

Please select at least one profile to delete.

Refer to error message text.

EID-2101

Protection switching error.

There was an error during the protection switch.

EID-2102

{0}
The forced switch could not be removed for some circuits. You must switch these circuits manually.

The forced switch could not be removed for some circuits. You must switch these circuits manually.

EID-2103

Span upgrade error.

There was an error during the span upgrade.

EID-2104

Unable to switch circuits back as one or both nodes are not reachable.

This error occurs during the path protection span upgrade procedure.

EID-2105

Span upgrade error.

There was an error during the span upgrade.

EID-2106

The node name cannot be empty.

You must supply a name for the node.

EID-2107

Error adding {0}, unknown host.

There was an error adding the specified item.

EID-2108

{0} is already in the network.

The specified item is already in the network.

EID-2109

The node is already in the current login group.

Refer to error message text.

EID-2110

Please enter a number between 0 and {0}.

You must enter a number in the range between 0 and the specified value.

EID-2111

This node ID is already in use. Please choose another.

Refer to error message text.

EID-2112

You must enter a number and it must be between 0 and {0}.

You must enter a number and it must be between 0 and the specified number.

EID-2113

Cannot set extension byte.
{0}

CTC cannot set the extension byte.

EID-2114

Card communication failure. Error applying operation.

This error can occur during an attempt to apply a BLSR protection operation to a line.

EID-2115

Error applying operation.
{0}

There was an error applying the specified operation.

EID-2116

Invalid extension byte setting.
{0}

The extension byte set is invalid.

EID-2118

Cannot delete ring. There is a protection operation set. All protection operations must be clear for ring to be deleted.

Refer to error message text.

EID-2119

Cannot delete {0} because a protection switch is in effect. Please clear any protection operations, make sure that the reversion time is not "never" and allow any protection switches to clear before trying again.

Refer to error message text.

EID-2120

The following nodes could not be unprovisioned
{0}
Therefore you will need to delete this {1} again later.

The specified nodes could not be unprovisioned.

EID-2121

Cannot upgrade ring.
{0}

CTC cannot upgrade the ring.

EID-2122

Inadequate ring speed for upgrade. Only {0} (or higher) {1} can be upgraded to 4-fiber.

You have selected an incorrect ring speed for upgrade. Only rings within the specified parameters can be upgraded to 4-fiber.

EID-2123

Non-upgradable nodes. Verify that the following nodes have at least two in-service ports with the same speed as the 2-fiber
{0}.
The ports cannot serve as a timing reference, and they cannot have DCC terminations or overhead circuits.
{1}

Nonupgradable nodes. Verify that the specified nodes have at least two in-service ports with the same speed as the 2-fiber.
The specified ports cannot serve as a timing reference, and they cannot have data communications channel (DCC) terminations or overhead circuits.

EID-2124

You cannot add this span because it is connected to a node that already has the east and west ports defined.

Refer to error message text.

EID-2125

You cannot add this span as it would cause a single card to host both the east span and the west span. A card cannot protect itself.

Refer to error message text.

EID-2126

OSPF area error.

There is an Open Shortest Path First (OSPF) area error.

EID-2127

You cannot add this span. It would cause some circuits to occupy different STS regions on different spans.

Refer to error message text.

EID-2128

Illegal state error.

An internal error occurred while trying to remove a span from a BLSR.

This alarm occurs in the network-level BLSR creation dialog box.

EID-2129

This port is already assigned. The east and west ports must be different.

Refer to error message text.

EID-2130

The ring ID value is not valid. Please enter a valid number between 0 and 9999.

Refer to error message text.

EID-2131

Cannot set reversion to INCONSISTENT.

You must select another reversion type.

EID-2132

Invalid ring ID.
{0}

The ring ID you entered is invalid. Please use another ID.

EID-2133

Node selection error.

There is an error selecting the node.

EID-2134

File not found. Unable to store overhead circuit preferences.

File not found. Unable to store overhead circuit preferences.

EID-2135

I/O error. Unable to store overhead circuit preferences.

Input/Output error. Unable to store overhead circuit preferences.

EID-2136

Circuit rename failed.
{0}

CTC could not rename the circuit.

EID-2137

Merge circuits error.

There was an error merging the circuits.

EID-2138

Cannot delete all destinations. Please try again.

Refer to error message text.

EID-2139

Error updating destinations.

There was an error updating the circuit destinations.

EID-2140

Merge circuits error.

There was an error merging the circuits.

EID-2141

No circuits selected.
{0}

You did not select a circuit.

EID-2142

Circuit deletion error.

There was an error deleting the circuit.

EID-2143

No online help version selected. Cannot delete the online help book.

You cannot delete the online help.

EID-2144

Error deleting online help book(s).
{0}

You cannot delete the online help.

EID-2145

Unable to locate a node with an IOS card.

Unable to locate a node with a Cisco IOS card.

EID-2146

Security violation. You may only logout your own account.

Refer to error message text.

EID-2147

Security violation. You may only change your own account.

Refer to error message text.

EID-2148

Security violation. You may not delete the account under which are currently logged in.

Refer to error message text.

EID-2173

Port unavailable. The desired CTC CORBA (IIOP) listener port, {0}, is already in use or you do not have permission to listen on it. Please select an alternate port.

The port is unavailable. The desired CTC Common Object Request Broker Architecture (CORBA) Internet Inter-ORB Protocol (IIOP) listener port is already in use or you do not have permission to listen on it. Please select an alternate port.

EID-2174

Invalid number entered. Please check it and try again.

You entered an invalid firewall port number.

EID-2175

Extension byte mismatch.
{0}

There is a mismatch with the extension byte.

EID-2176

Not all spans have the same OSPF Area ID. This will cause problems with protection switching. To determine the OSPF Area for a given span, place the cursor mouse over the span and the OSPF Area will be displayed.

Refer to error message text.

EID-2177

Extension byte mismatch.
{0}

There is a mismatch with the extension byte.

EID-2178

Only one edit pane can be opened at a time. The existing pane will be displayed.

Refer to error message text.

EID-2179

There is no update as the circuit has been deleted.

Because the circuit has been deleted, there is no update for it.

EID-2180

CTC initialization failed in step {0}.

CTC initialization failed in the specified step.

EID-2181

This link may not be included as it originates from the destination.

Refer to error message text.

EID-2182

The value of {0} is invalid.

The value of the specified item is invalid.

EID-2184

Cannot enable the Spanning Tree Protocol (STP) on some ports because they have been assigned an incompatible list of VLANs. You can view the VLAN/Spanning Tree table or reassign ethernet ports VLANs

Refer to error message text.

EID-2185

Cannot assign the VLANs on some ports because they are incompatible with the STP. You can view the VLAN/Spanning Tree table or reassign VLANs

Refer to error message text.

EID-2186

Software download failed on node {0}.

The software could not be downloaded onto the specified node.

EID-2187

The maximum length for the ring name that can be used is {0}. Please try again.

You must shorten the length of the ring name.

EID-2188

The nodes in this ring do not support alphanumeric IDs. Please use a ring ID between {0} and {1}.

The nodes in this ring do not support alphanumeric IDs. Please use a ring ID within the specified range.

EID-2189

TL1 keyword "all" can not be used as the ring name. Please provide another name.

Refer to error message text.

EID-2190

Adding this span will cause the ring to contain more nodes than allowed.

Refer to error message text.

EID-2191

Ring name must not be empty

You must supply a ring name.

EID-2192

Cannot find a valid route for the circuit creation request.

Refer to error message text.

EID-2193

Cannot find a valid route for the circuit drop creation request.

Refer to error message text.

EID-2194

Cannot find a valid route for the roll creation request.

Refer to error message text.

EID-2195

The circuit VLAN list cannot be mapped to one spanning tree.

You can view the VLAN/Spanning Tree table or reassign VLANs.

Refer to error message text.

EID-2196

Unable to relaunch the CTC. {0}

There is an error relaunching CTC.

EID-2197

CORBA failure. Unable to proceed.

There was a CORBA failure, and the task cannot proceed.

EID-2198

Unable to switch to the {0} view.

CTC is unable to switch to the specified view.

EID-2199

Login failed on {0} {1}

The login failed on the specified task.

EID-2200

CTC has detected a jar file deletion. The jar file was used to manage one or more nodes. This CTC session will not be able to manage those nodes and they will appear gray on the network map. It is recommended that you exit this CTC session and start a new one.

Refer to error message text.

EID-2201

{0}

CTC encountered an error.

EID-2202

Intra-node circuit must have 2 sources to be Dual Ring Interconnect.

Intra-node circuit must have two sources to be a dual-ring interconnect (DRI).

EID-2203

No member selected.

You must select a member.

EID-2204

Number of circuits must be a positive integer

The number of circuits cannot be negative.

EID-2205

Circuit Type must be selected

You must select a circuit type.

EID-2206

Unable to autoselect profile! Please select profile(s) to store and try again.

Refer to error message text.

EID-2207

You cannot add this span. Either the ring name is too big (i.e., ring name length is greater than {0}) or the endpoints do not support alphanumeric IDs.

You cannot add this span. Either the ring name is too big (that is, the ring name length is greater than the specified length) or the endpoints do not support alphanumeric IDs.

EID-2208

This is an invalid or unsupported JRE

The version of Java Runtime Environment (JRE) is either invalid or unsupported.

EID-2209

The user name must be at least {0} characters long.

The user name must be at least the specified character length.

EID-2210

No package name selected

You must select a package name.

EID-2211

No node selected for upgrade

You must select a node for the upgrade.

EID-2212

Protected Line is not provisionable

The protected line cannot be provisioned.

EID-2214

The node is disconnected. Please wait till the node reconnects.

Refer to error message text.

EID-2215

Error while leaving {0} page.

There was an error while leaving the specified page.

EID-2216

Error while entering {0} page.

There was an error entering the specified page.

EID-2217

Some conditions could not be retrieved from the network view

Refer to error message text.

EID-2218

Bandwidth must be between {0} and {1} percent.

The bandwidth must be within the specified parameters.

EID-2219

Protection operation failed, XC loopback is applied on cross-connection

Protection operation failed; a cross-connect (XC) loopback will be applied on cross-connection.

EID-2220

The tunnel status is INCOMPLETE. CTC will not be able to change it.

Please try again later

Refer to error message text.

EID-2990

Ethernet circuits must be bidirectional.

You attempted to make an Ethernet circuit unidirectional.

EID-2991

Error while creating connection object at {0}.

There was an error creating a connection object at the specified location.

EID-2992

DWDM Link can be used only for Optical Channel circuits.

The dense wavelength division multiplexing (DWDM) link can be used only for optical channel network connection (OCHNC) circuits.

EID-2993

Ochnc circuit link excluded - wrong direction.

The OCHNC circuit link is excluded because it is in the wrong direction.

EID-2994

DWDM Link does not have Wavelength available.

Refer to error message text.

EID-2995

Laser already ON.

Refer to error message text.

EID-3001

An Ethernet RMON threshold with the same parameters already exists. Please change one or more of the parameters and try again.

An Ethernet remote monitoring (RMON) threshold with the same parameters already exists. Please change one or more of the parameters and try again.

EID-3002

Error retrieving defaults from the node {0}

There was an error retrieving the defaults from the specified node.

EID-3003

Cannot load file {0}

CTC cannot load the specified file.

EID-3004

Cannot load properties from the node

Refer to error message text.

EID-3005

Cannot save NE Update values to file {0}

CTC cannot save the network element (NE) update values to the specified file.

EID-3006

Cannot load NE Update properties from the node

Refer to error message text.

EID-3007

Provisioning Error for {0}

There was a provisioning error for the specified item.

EID-3008

Not a Barolo Card

You cannot perform DWDM automatic node setup (ANS) from the Card view. Please navigate to the Shelf view and try again.

EID-3009

No {0} selected

No item selected.

EID-3010

Unable to Create Bidirectional Optical Link

Refer to error message text.

EID-3011

The file {0} doesn't exist or cannot be read

The specified file does not exist or cannot be read.

EID-3012

The size of {0} is zero

The size of the item is zero.

EID-3013

{0} encountered while restoring DB

The specified item was encountered while restoring the database (DB).

EID-3014

Job terminated, {0} was encountered

The job terminated because the specified item was encountered.

EID-3015

{0} encountered while performing DB backup

The specified item was encountered while performing the DB backup.

EID-3016

Invalid subnet address

Refer to error message text.

EID-3017

Subnet address already exists

Refer to error message text.

EID-3018

Standby TSC not ready

The standby Timing and Shelf Control card (TSC) not ready.

EID-3019

Incomplete internal subnet address

There is an incomplete internal subnet address.

EID-3020

TSC One and TSC Two subnet addresses cannot be the same

Refer to error message text.

EID-3021

{0}

CTC encountered an error.

EID-3022

Requested action not allowed

The requested action is not allowed.

EID-3023

Unable to retrieve Low Order Cross Connect Mode

Refer to error message text.

EID-3024

unable to switch Low Order Cross Connect Mode

Refer to error message text.

EID-3025

Error in getting thresholds

The was an error retrieving the thresholds.

EID-3026

Cannot modify Send DoNotUse

CTC cannot modify Send DoNotUse.

EID-3027

Cannot modify EnableSyncMsg

CTC cannot modify EnableSyncMsg.

EID-3028

Cannot change port type

CTC cannot change the port type.

EID-3029

Unable to switch to the byte because an overhead change is present on this byte of the port

Refer to error message text.

EID-3031

Error hard-resetting card

There was an error hard-resetting card.

EID-3032

Error resetting card

There was an error resetting the card.

EID-3033

The lamp test is not supported on this shelf

Refer to error message text.

EID-3034

Communication failure

There was a communication failure.

EID-3035

The Cross Connect Diagnostics cannot be performed

Refer to error message text.

EID-3036

The Cross Connect Diagnostics test is not supported on this shelf/CORBA.BAD_OPERATION

The cross-connect diagnostics test is not supported on this shelf.

EID-3037

A software downgrade cannot be performed to the selected version while a SSXC card is inserted in this shelf. Please follow the steps to replace the SSXC with a CXC card before continuing the software downgrade.

A software downgrade cannot be performed to the selected version while a Single-Shelf Cross-Connect (SSXC) card is inserted in this shelf. Please follow the steps to replace the SSXC with a Core Cross-Connect card (CXC) card before continuing the software downgrade.

EID-3038

A software downgrade cannot be performed at the present time.

Refer to error message text.

EID-3039

Card change error

There was a card change error.

EID-3040

Invalid card type

The card type is invalid.

EID-3041

Error Applying Changes

There was an error applying the changes.

EID-3042

The Flow Ctrl Lo value must be less than the Flow Ctrl Hi value for all ports in the card.

Refer to error message text.

EID-3043

Error in getting Line Info settings

Refer to error message text.

EID-3044

Error in getting Line Admin Info settings

Refer to error message text.

EID-3045

Error in getting Transponder Line Admin Info settings

Refer to error message text.

EID-3046

The flow control water mark value must be between {0} and {1}, inclusive.

The flow control watermark value must be between the specified values.

EID-3047

The file named {0} could not be read. Please check the name and try again.

The specified file could not be read. Please check the name and try again.

EID-3048

There is no IOS startup config file available to download.

There is no Cisco IOS startup configuration file available to download.

EID-3049

There was a software error attempting to download the file. Please try again later.

Refer to error message text.

EID-3050

An exception was caught trying to save the file to your local file system

Refer to error message text.

EID-3051

The maximum size for a config file in bytes is {0}

The maximum size for a configuration file in bytes is the value specified in the message.

EID-3052

There was an error saving the config file to the TCC.

Refer to error message text.

EID-3053

The value of {0} must be between {1} and {2}

The value of the item must be between the specified values.

EID-3054

Cannot remove provisioned input/output ports or another user is updating the card, please try later.

Cannot remove provisioned input/output ports or another user is updating the card. Please try later.

EID-3055

Can't Create Soak Maintance Pane

CTC cannot create Soak Maintenance Pane.

EID-3056

Cannot save defaults to file {0}

Cannot save defaults to the specified file.

EID-3057

Cannot load default properties from the node

Refer to error message text.

EID-3058

File {0} does not exist

The specified file does not exist.

EID-3059

Error in refreshing

There was an error in refreshing.

EID-3060

The ALS Recovery Interval must be between 100 seconds and 300 seconds.

The automatic laser shutdown (ALS) Recovery Interval must be between 100 seconds and 300 seconds.

EID-3061

The ALS Recovery Pulse Width must be between 2.00 seconds and 100.0 seconds.

The ALS Recovery Pulse Width must be between 2.00 seconds and 100.0 seconds.

EID-3062

Error in setting values

Refer to error message text.

EID-3063

Error in getting Bridge Port settings

Refer to error message text.

EID-3064

Not a G1000 Card

This card is not a G1000 card.

EID-3065

Create Ether Threshold

You must create an Ethernet threshold.

EID-3066

Minimum sample period must be greater than or equal to 10

Refer to error message text.

EID-3067

Rising Threshold Invalid Entry, valid range is from 1 to {0}

This is an invalid rising threshold entry. The valid range is from 1 to the specified value.

EID-3068

Falling Threshold Invalid Entry, valid range is from 1 to {0}

This is an invalid falling threshold entry. The valid range is from 1 to the specified value.

EID-3069

Rising Threshold must be greater than or equal to Falling Threshold

Refer to error message text.

EID-3070

Error in Data For Ports {0} Exactly one VLAN must be marked Untagged for each port. These changes will not be applied.

There was an error in the data for the specified ports. Exactly one VLAN must be marked Untagged for each port. These changes will not be applied.

EID-3071

Get Learned Address

Unable to retrieve the learned MAC address from the NE..

EID-3072

Clear Learned Address

Failure attempting to clear the learned MAC address from a specific card or ethergroup.

EID-3073

Clear Selected Rows

Failure attempting to clear the learned MAC address from a specific card or ethergroup.

EID-3074

Clear By {0}

Error encountered trying to clear the learned MAC address from either a VLAN or a port.

EID-3075

At least one row in Param column needs to be selected.

Refer to error message text.

EID-3076

CTC lost its connection with this node. The NE Setup Wizard will exit.

Refer to error message text.

EID-3077

No Optical Link Selected

Refer to error message text.

EID-3078

Unable to Create Optical Link

Refer to error message text.

EID-3079

Cannot apply defaults to node {0}

Cannot apply defaults to the specified node.

EID-3080

Cannot go to the target tab
{0}

Cannot go to the target tab.

EID-3081

Port type can't be changed

Refer to error message text.

EID-3082

Cannot modify the {0} extension byte

Cannot modify the extension byte.

EID-3083

Error in getting stats

Error in getting statistics.

EID-3084

OSC termination is in use. Error deleting OSC Termination

Optical service channel (OSC) termination is in use. Error deleting OSC termination.

EID-3085

No OSC Terminations selected

Refer to error message text.

EID-3086

One or more Osc terminations could not be created

Refer to error message text.

EID-3087

OSC termination could not be edited

Refer to error message text.

EID-3088

No {0} card to switch

No card of the specified type to switch.

EID-3089

Can't use/change {0} state when {0} is failed or missing.

Cannot use/change the specified state when it is failed or missing.

EID-3090

Can't perform operation as {0} is {1}LOCKED_ON/LOCKED_OUT.

Cannot perform operation.

EID-3091

Can't perform the operation as protect is active.

Refer to error message text.

EID-3092

Can't perform the operation in module's current state.

Refer to error message text.

EID-3093

Can't perform the operation as duplex pair is {0}locked.

Refer to error message text.

EID-3094

Can't perform the operation as no XC redundancy is available.

Refer to error message text.

EID-3095

Deletion failed since the circuit is in use

Refer to error message text.

EID-3096

The Ring ID could not be created

Refer to error message text.

EID-3097

The ring termination is in use.

Refer to error message text.

EID-3098

No Ring Terminations selected

Refer to error message text.

EID-3099

Sorry, entered key does not match existing Authentication key.

The entered key does not match existing authentication key.

EID-3100

Error in authentication

There was an error in authentication.

EID-3101

DCC Metric is not in the range 1 - 65535.

The DCC Metric is not in the range 1 to 65535.

EID-3102

Invalid DCC Metric

There was an Invalid DCC Metric.

EID-3103

Invalid IP Address {0}

The IP Address is Invalid.

EID-3104

Router priority is not in the range of 0 - 255

The Router priority is not in the range of 0 to 255.

EID-3105

Invalid Router Priority

The Router Priority is Invalid.

EID-3106

Hello Interval is not in the range of 1 - 65535

The Hello Interval is not in the range of 1 to 65535.

EID-3107

Invalid Hello Interval

The Hello Interval is Invalid.

EID-3108

Dead Interval is not in the range 1 - 0x7fffffff

The Dead Interval is not in the range 1 to 0x7fffffff.

EID-3109

Invalid Dead Interval

The Dead Interval is invalid.

EID-3110

Dead Interval must be larger than Hello Interval

Refer to error message text.

EID-3111

LAN transit delay is not in the range of 1 - 3600 seconds

The LAN transit delay is not in the range of 1 to 3600 seconds.

EID-3112

Invalid Transit Delay

The transmit delay is invalid.

EID-3113

Retransmit Interval is not in the range 1 - 3600 seconds

The retransmit interval is not in the range 1 to 3600 seconds.

EID-3114

Invalid Retransit Int

The retransmit interval is invalid.

EID-3115

LAN Metric is not in the range 1 - 65535.

The LAN Metric is not in the range 1 to 65535.

EID-3116

Invalid LAN Metric

The LAN Metric is invalid.

EID-3117

If OSPF is active on LAN, no DCC Area Ids may be 0.0.0.0. Please change all DCC Area Ids to non-0.0.0.0 values before enabling OSPF on the LAN.

Refer to error message text.

EID-3118

If OSPF is active on LAN, LAN Area ID may not be the same as DCC Area Id.

Refer to error message text.

EID-3119

Validation Error

There is a validation error.

EID-3120

No object of type {0} selected to delete

No object of the selected type selected to delete.

EID-3121

Error Deleting {0}

There is an error deleting the item.

EID-3122

No object of type {0} selected to edit

No object of the specified type selected to edit.

EID-3123

Error Editing {0}

There was an error editing the item.

EID-3124

{0} termination is in use. Check if {0} is used by IPCC.

The specified termination is in use.

EID-3125

No {0} Terminations selected

No specified terminations are selected.

EID-3126

{0} termination could not be edited

The specified termination could not be edited.

EID-3127

Unable to provision orderwire because E2 byte is in use by BLSR.

Refer to error message text.

EID-3128

The authentication key may only be {0} characters maximum

The authentication key can only be the specified characters maximum.

EID-3129

The authentication keys do not match!

Refer to error message text.

EID-3130

Error creating Area Virtual Link

CTC encountered an error creating the Area Virtual Link.

EID-3131

Error creating Virtual Link

CTC encountered an error creating the Virtual Link.

EID-3132

Error setting area range {0}, {1}, false.

CTC encountered an error setting the area range for the specified values.

EID-3133

Max number Of Area Ranges Exceeded

The maximum number of area ranges has been exceeded.

EID-3134

Invalid Area ID. Use DCC OSPF Area ID, LAN Port Area ID, or 0.0.0.0.

Refer to error message text.

EID-3135

Invalid Mask

Refer to error message text.

EID-3136

Invalid Range Address

Refer to error message text.

EID-3137

Your request has been rejected because the timing source information was updated while your changes were still pending. Please retry.

Refer to error message text.

EID-3138

Invalid clock source for switching.

Refer to error message text.

EID-3139

Cannot switch to a reference of inferior quality.

Refer to error message text.

EID-3140

Higher priority switch already active.

Refer to error message text.

EID-3141

Attempt to access a bad reference.

Refer to error message text.

EID-3142

No Switch Active.

Refer to error message text.

EID-3143

Error creating Static Route Entry

Refer to error message text.

EID-3144

Max number Of Static Routes Exceeded

The maximum number of static routes has been exceeded.

EID-3145

RIP Metric is not in the range 1-15.

The Routing Information Protocol (RIP) metric is not in the range 1 to 15.

EID-3146

Invalid RIP Metric

Refer to error message text.

EID-3147

Error creating Summary Address

Refer to error message text.

EID-3148

No Layer 2 domain selected

Refer to error message text.

EID-3149

Unable to retrieve MAC addresses

Refer to error message text.

EID-3150

The target file {0} is not a normal file.

The specified target file is not a normal file.

EID-3151

The target file {0} is not writeable.

The specified target file is not writeable.

EID-3152

Error creating Protection Group

CTC encountered an error creating Protection Group.

EID-3153

Cannot delete card, it is in use

Cannot delete card. It is in use.

EID-3154

Cannot {0} card, provision error

CTC cannot perform the task on the card.

EID-3155

Error Building Menu

CTC encountered an error building the menu.

EID-3156

Error on building menu (cards not found for {0} group)

CTC encountered an error on building menu (cards not found for the specified group).

EID-3157

setSelectedModel unexpected model class {0}

CTC encountered an unexpected model class while trying to complete the task.

EID-3158

Unable to switch, a similar or higher priority condition exists on peer or far-end card

Refer to error message text.

EID-3159

Error applying operation

CTC encountered an error applying this operation.

EID-3160

{0} Error

CTC encountered the displayed error.

EID-3161

Ring Upgrade Error

Refer to error message text.

EID-3162

This protection operation cannot be set because the protection operation on the other side has been changed but not yet applied.

Refer to error message text.

EID-3163

Cannot validate data for row {0}

Cannot validate data for the specified row.

EID-3164

New Node ID ({0}) for Ring ID {1} duplicates ID of node {3}

The new specified Node ID for the specified Ring ID is the same as the second specified Node ID.

EID-3165

Ring IDs must be unique

Refer to error message text.

EID-3166

Error refreshing {0} table

CTC encountered an error refreshing the specified table.

EID-3167

Slot already in use

Refer to error message text.

EID-3169

Error Adding Card

CTC encountered an error adding the card.

EID-3170

Cannot delete card, {0}

Cannot delete the specified card.

EID-3171

Error creating Trap Destination

CTC encountered an error creating the trap destination.

EID-3172

No Ether Thresholds selected

Refer to error message text.

EID-3173

The contact '{0}' exceeds the limit of {1} characters.

The specified contact exceeds the specified character limit.

EID-3174

The location '{0}' exceeds the limit of {1} characters.

The specified location exceeds the specified character limit.

EID-3175

The operator identifier '{0}'exceeds the limit of {1} characters.

The specified operator identifier exceeds the specified character limit.

EID-3176

The operator specific info '{0}'exceeds the limit of {1} characters.

The specified operator specific information exceeds the specified character limit.

EID-3177

The name '{0}' is empty!

The specified name is empty.

EID-3178

The name '{0}' exceeds the limit of {1} characters.

The specified name exceeds the specified character limit.

EID-3179

Protect card is in use

Refer to error message text.

EID-3180

1+1 Protection Group does not exist.

Refer to error message text.

EID-3181

Y Cable Protection Group does not exist.

Refer to error message text.

EID-3182

The Topology Element is in use and can't be deleted as requested

Refer to error message text.

EID-3183

Error Deleting Protection Group

CTC encountered an error deleting the protection group.

EID-3184

No {0} selected

You must select an item before completing this task.

EID-3185

There is a protection switch operation on this ring. Therefore, it cannot be deleted at this time.

Refer to error message text.

EID-3186

Busy {0} is {1} and cannot be deleted as requested.

The item is in use and cannot be deleted as requested.

EID-3187

Error deleting Trap Destination

CTC encountered an error deleting the trap destination.

EID-3188

Invalid UCP Node ID value

Invalid Unified Control Plane (UCP) Node ID value.

EID-3189

Invalid Circuit Retry Initial Interval value

Refer to error message text.

EID-3190

Invalid Circuit Retry Max Interval value

Refer to error message text.

EID-3191

Invalid RSVP Recovery value

Invalid Resource Reservation Protocol (RSVP) recovery value.

EID-3192

Invalid RSVP Refresh value

Refer to error message text.

EID-3193

Invalid RESV timeout value

Invalid reservation (RESV) timeout value.

EID-3194

Invalid RESV CONF timeout value

Invalid reservation confirmation (RESV CONF) timeout value.

EID-3195

Invalid Source Deletion in Progress timeout value

Refer to error message text.

EID-3196

Invalid Destination Deletion in Progress timeout value

Refer to error message text.

EID-3197

Unable to delete circuit origin/termination {0}

Unable to delete the specified circuit origin/termination.

EID-3198

Error refreshing UCP circuit table

Refer to error message text.

EID-3199

Unable to delete UCP Interface {0}

Unable to delete the specified UCP interface.

EID-3200

TNA Address may not be empty

Transport network assigned (TNA) address cannot be empty.

EID-3201

Error refreshing UCP Interface table

Refer to error message text.

EID-3202

Unable to delete IPCC {0}

Unable to delete the specified IP contact center (IPCC).

EID-3203

{0} IPCC may not be empty

The specified IPCC cannot be empty.

EID-3204

Invalid {0} IPCC value

The specified IPCC value is invalid.

EID-3205

MTU value may not be empty for SDCC IPCC

The maximum transmission unit (MTU) value can not be empty for SDCC IPCC.

EID-3206

MTU value may not be negative

MTU value cannot be negative.

EID-3207

Error refreshing IPCC table

Refer to error message text.

EID-3208

Unable to delete neighbor {0}

Unable to delete the specified neighbor.

EID-3209

Neighbor name may not be empty.

Refer to error message text.

EID-3210

Neighbor name may not exceed {0} characters

Neighbor name cannot exceed the specified number of characters.

EID-3211

Error refreshing table

Encountered an error while responding to an update event from the NE. Unable to properly refresh the table values.

EID-3212

IPCC Create Error

Error creating the IPCC.

EID-3213

UCP Neighbor Create Error

Error creating the UCP neighbor.

EID-3214

Could not get number of HOs for line

Refer to error message text.

EID-3215

Error in refreshing

Used frequently in pane classes to indicate a general error condition when trying to refresh from the model.

EID-3216

Invalid Proxy Port

Invalid Proxy port.

EID-3217

Could not refresh stats.

Could not refresh statistics.

EID-3218

Launch ANS

Launch advanced network service (ANS).

EID-3219

Refresh ANS

Failure trying to retrieve optical link information.

EID-3220

Error refreshing row {0}

Error refreshing the specified row.

EID-3221

Communication Error

Refer to error message text.

EID-3222

Could not clear stats

Refer to error message text.

EID-3223

Error cancelling software upgrade

Refer to error message text.

EID-3224

Error accepting load

Refer to error message text.

EID-3225

Error in pane refresh

Refer to error message text.

EID-3226

Error refreshing page

Refer to error message text.

EID-3227

Could not set baseline

Refer to error message text.

EID-3228

Error refreshing screen

Refer to error message text.

EID-3229

RIP is active on the LAN. Please disable RIP before enabling OSPF.

RIP is active on the LAN. Please disable RIP before enabling OSPF.

EID-3230

OSPF is active on the LAN. Please disable OSPF before enabling RIP.

OSPF is active on the LAN. Please disable OSPF before enabling RIP.

EID-3231

Error in Set OPR

Error in setting optical power received (OPR).

EID-3232

Cannot transition port state indirectly: try editing directly

Refer to error message text.

EID-3233

Current loopback provisioning does not allow this state transition

Refer to error message text.

EID-3234

Current synchronization provisioning does not allow this state transition

Refer to error message text.

EID-3235

Cannot transition state on monitored port

Refer to error message text.

EID-3236

DB Restore failed. {0}

The specified database restore failed.

EID-3237

DB Backup failed. {0}

The specified database backup failed.

EID-3238

Send PDIP setting on {0} is inconsistent with that of control node {1}

Send payload defect indication (PDIP) setting on the specified item is inconsistent with that of the specified control node.

EID-3239

The overhead termination is invalid

Refer to error message text.

EID-3240

The maximum number of overhead terminations has been exceeded

Refer to error message text.

EID-3241

The {0} termination port is in use

The specified termination port is in use.

EID-3242

LDCC exists on the selected ports.

Please create SDCC one by one.

The line DCC (LDCC) exists on the selected ports. Please create SDCC one by one.

EID-3244

SDCC exists on the selected ports.

Please create LDCC one by one.

SDCC exists on the selected ports. Please create LDCC one by one.

EID-3246

{0}

CTC encountered an error.

EID-3247

Ordering error. The absolute value should be {0}

Ordering error. The absolute value should be the number specified.

EID-3248

Wrong parameter is changed: {0}

CTC changed the wrong parameter.

EID-3249

Invalid voltage increment value.

Refer to error message text.

EID-3250

Invalid power monitor range.

Refer to error message text.

EID-3251

Unable to complete requested action. {0}

CTC is unable to complete requested action.

EID-3252

No download has been initiated from this CTC

Refer to error message text.

EID-3253

Reboot operation failed. {0}

The reboot operation failed.

EID-3254

{0}

CTC encountered an error.

EID-3255

Can not change timing configuration, manual/force operation is performed.

Refer to error message text.

EID-3257

Duplicate DCC number detected: {0}.

CTC detected a duplicate DCC number.

EID-3258

There was a software error attempting to download the file. Please try again later.

Refer to error message text.

EID-3259

Create Fcmr Threshold

You must create an FCMR threshold.

EID-3260

Error refreshing page {0}.

There was an error refreshing the specified page.

EID-3261

The port rate provisioning cannot be changed while circuits exist on this port.

CTC does not allow you to change the port rate from 1-Gbps to 2-Gbps if a VCAT STS-24c circuit exists on the port. Software Release 4.6 only supports line-rate SONET circuits.

EID-3262

The port provisioning cannot be changed when the port status is not OOS.

Refer to error message text.

EID-3264

The port provisioning cannot be changed while the port is in service.

Refer to error message text.

EID-3265

Error modifying Protection Group

There was an error modifying the protection group.

EID-3266

Conditions could not be retrieved from the shelf or card view

Refer to error message text.

EID-3267

Cannot edit XTC protection group

Refer to error message text.

EID-3268

Invalid entry. {0}

The entry is invalid.

EID-3269

{0} was successfully initiated for {1} but its completion status was not able to be obtained from the node. {0} may or may not have succeeded. When the node is accessible, check its software version.

The specified task was successfully initiated for the item, but its completion status was not able to be obtained from the node. The task might or might not have succeeded. When the node is accessible, check its software version.

EID-3270

The file {0} does not exist.

The specified file does not exist.

EID-3271

The value entered must be greater than {0}.

The value entered must be greater than the value shown.

EID-3272

Entry required

An entry is required for this task.

EID-3273

{0} already exists in the list.

The specified item already exists in the list.

EID-3290

The ALS Recovery Pulse Width must be between 80.00 seconds and 100.0 seconds.

Refer to error message text.

EID-3291

Cannot Change Revertive Behavior due to an active protection switch

Refer to error message text.

EID-3938

Unable to Perform Operation.

CTC is unable to perform operation.

EID-3939

Wrong Node Side.

This task was applied to the wrong node side.

EID-3940

Name too long.

The name you entered is too long.

EID-3941

Illegal name.

The name you entered is illegal.

EID-3942

Wrong line selection.

You selected the wrong line.

EID-3945

Unable to Delete Optical Link

CTC is unable to delete the optical link.

EID-3946

No NetworkType Available

There is no network type available.

EID-3947

At Least One Equipment Is Not Plugged

At least one equipment is not plugged in.

EID-3948

Apc System Is Busy

Automatic power control (APC) system is busy.

EID-3949

No Path To Regulate

There is no circuit path to be regulated.

EID-3950

Requested action not allowed.

Generic DWDM provisioning failure message.

EID-3951

Wrong input value.

The input value is incorrect.

EID-3952

Error in getting thresholds.

There was an error retrieving the thresholds.

EID-3953

Error applying changes to row {0}. Value out of range.

There was an error applying the changes to the specified row. The value is out of range.

EID-3954

Invalid mode for current configuration.

Refer to error message text.

EID-3955

Unable to switch to the byte because.an overhead channel is present on this byte of the port.

Refer to error message text.

EID-3956

Error applying changes to row

There was an error applying changes to the row.

EID-3957

Error on setting expected wavelength

There was an error setting the expected wavelength.

EID-3958

Error on setting expected band

There was an error setting the expected band.

EID-3959

might parameters on Protect Port.

You cannot change timing parameters on protect port.

EID-3960

This port's type cannot be changed SDH validation check failed. Check if this port is part of a circuit, protection group, SONET DCC, orderwire, or UNI-C interface.

This port's type cannot be changed. The SDH validation check failed. Check to see if this port is part of a circuit, protection group, SONET DCC, orderwire, or User Network Interface, client (UNI-C) interface.

EID-3961

getControlMode

The Control Mode must be retrieved.

EID-3962

setGainSetPoint

The Gain Set Point must be set.

EID-3963

getGainSetPoint

The Gain Set Point must be retrieved.

EID-3964

setTiltCalibration

The tilt calibration must be set.

EID-3965

setExpectedWavelength

The expected wavelength must be set.

EID-3966

getExpectedWavelength

The expected wavelength must be retrieved.

EID-3967

getActualWavelength

The actual wavelength must be retrieved.

EID-3968

getActualBand

The actual band must be retrieved.

EID-3969

getExpectedBand

The expected band must be retrieved.

EID-3970

setExpectedBand

The expected band must be set.

EID-3971

Error retrieving defaults from the node {0}.

There was an error retrieving defaults from the specified node.

EID-3972

Cannot load file {0}

CTC cannot load the specified file.

EID-3973

Cannot load properties from the node

CTC cannot load properties from the node.

EID-3974

Cannot save NE Update values to file

CTC cannot save NE Update values to file.

EID-3975

Cannot load NE Update properties from the node

CTC cannot load NE Update properties from the node.

EID-3976

File {0} does not exist.

The specified file does not exist.

EID-3977

Error on setting value at {0}

There was an error setting the value at the specified location.

EID-3978

NoSuchInterface.

No such interface exists in CTC.

EID-3979

EndPointInUse.

The end point is in use.

EID-3980

EndPointIncompatible.

The end point is incompatible.

EID-3981

Unable to call

CTC is unable to call.

EID-3982

Unable to Calculate Connections.

CTC is unable to calculate connections.

EID-3983

OptLinkModel does not exist for index =

The OptLinkModel does not exist for the specified index.

EID-3984

Unable to call ANS.setNodeOpticalParam CannotPerform.

Refer to error message text.

EID-3985

Unable to call ANS.setNodeOpticalParam FeatureUnsupported.

Refer to error message text.

EID-3986

ring termination is in use. Error deleting ring Termination.

Refer to error message text.

EID-3987

Error deleting ring Termination.

There was an error deleting ring termination.

EID-3988

No Ring Terminations selected.

You must select a ring termination.

EID-3989

Error creating Ring ID.

There was an error creating the ring ID.

EID-3990

OSC termination is in use.

The OSC termination is in use.

EID-3991

Error deleting OSC Termination.

There was an error deleting the OSC termination.

EID-3992

No OSC Terminations selected.

There are no OSC terminations selected.

EID-3993

One or more Osc termination could not be created.{0}

The specified OSC termination could not be created.

EID-3994

OSC termination could not be edited.

The OSC termination could not be edited.

EID-3995

No Optical Link selected.

You must select an optical link.

EID-3996

ERROR on calculate automatic optical link list.

There was an error calculating the automatic optical link list.

EID-3997

Attempt to access an Ochnc Connection that has been destroyed.

You attempted to access an OCHNC connection that has been destroyed.

EID-3998

Tunnel Type Could not be changed Do you wish to roll back?

The tunnel type could not be changed. Do you wish to roll back?

EID-3999

Tunnel repair failed

CTC could not repair the tunnel.

EID-9990

Test message with no variable data.

Refer to error message text.

WID-2149

There is nothing exportable on this view.

Refer to error message text.

WID-2150

Node not initialized. Please wait and try again.

Refer to error message text.

WID-2151

Wait until all the circuits have been repaired to begin a bridge and roll operation on the circuits.

Refer to error message text.

WID-2152

Spanning tree protection is being disabled for this circuit.

Refer to error message text.

WID-2153

Adding this drop makes the circuit a PCA circuit.

Refer to error message text.

WID-2154

Disallow creating monitor circuits on a port grouping circuit.

Refer to error message text.

WID-2155

Only partial switch count support on some nodes.
{0}

Refer to error message text.

WID-2156

Manual roll mode is recommended for dual rolls. For auto dual rolls, please verify that roll to facilities are in service and error free.

Refer to error message text.

WID-2157

Cannot complete roll(s).
{0}

CTC cannot complete the roll(s).

WID-2158

Invalid roll mode.
{0}

The selected roll mode is invalid.

WID-2159

Roll not ready for completion.
{0}

The roll is not ready for completion.

WID-2160

Roll not connected.
{0}

The selected roll is not connected.

WID-2161

Sibling roll not complete.
{0}

The sibling roll is not complete.

WID-2162

Error during roll acknowledgement.
{0}

There was an error during the roll acknowledgement.

WID-2163

Cannot cancel roll.
{0}

CTC cannot cancel the roll.

WID-2164

Roll error.
{0}

CTC encountered a roll error.

WID-2165

The MAC address of node {0} has been changed. All circuits originating from or dropping at this node will need to be repaired.

The MAC address of the specified node has been changed. All circuits originating from or dropping at this node need to be repaired.

WID-2166

Unable to insert node into the domain. The node is not initialized.

Refer to error message text.

WID-2167

Insufficient security privilege to perform this action.

You have insufficient security privilege to perform this action.

WID-2168

Warnings loading {0}.
{1}

CTC encountered warnings while loading the specified item.

WID-2169

One or more of the profiles selected do not exist on one or more of the nodes selected.

Refer to error message text.

WID-2170

The profile list on node {0} is full. Please delete one or more profiles if you wish to add profile {1}.

The profile list on the specified node is full. Please delete one or more profiles if you wish to add the specified profile.

WID-2171

You have been logged out. Click OK to exit CTC.

Refer to error message text.

WID-2172

The CTC CORBA (IIOP) listener port setting of {0} will be applied on the next CTC restart.

The specified CTC CORBA (IIOP) listener port setting will be applied on the next CTC restart.

WID-2213

The current type or state of some drops does not allow the new circuit state of {0} to be applied to them indirectly.

The current type or state of some drops does not allow the specified new circuit state to be applied to them indirectly.

WID-3243

LDCC exists on the selected port. Please remove one after the connection is created.

Refer to error message text.

WID-3245

SDCC exists on the selected port. Please remove one after the connection is created.

Refer to error message text.

WID-3256

Could not assign timing reference(s) because at least one timing reference has already been used and/or a timing reference has been attempted to be used twice.

Please use the "Reset" button and verify the settings.

Refer to error message text.

WID-3263

You are using Java version {0}. CTC should run with Java version {1}.

It can be obtained from the installation CD or http://java.sun.com/j2se/

You are using the Java version specified in the first sentence of this message. CTC should run with the Java version specified in the second sentence of this message. The correct Java version can be obtained from the installation CD or at http://java.sun.com/j2se/.

WID-3274

A software upgrade is in progress. Network configuration changes that results a node reboot can not take place during software upgrade.

Please try again after software upgrade is done.

Refer to error message text.

WID-3275

Make sure the Remote Interface ID and the Local Interface ID on the two sides are matched. (Local Interface ID on this node should equal Remote Interface ID on the neighbor node and vice-versa).

Refer to error message text.

WID-3276

Both SDCC and LDCC exist on the same selected port. {0}

Both SDCC and LDCC exist on the same selected port.

WID-3277

The description can't contain more than {0} characters. Your input will be truncated.

Refer to error message text.

WID-3278

{0} is not initialized. Please wait and try again.

The specified object is not initialized. Please wait and try again.

WID-3279

Card Deleted, Returning to shelf View

This card has been deleted. CTC is returning to shelf view.

WID-3280

ALS will not engage until both the protected trunk ports detect LOS

ALS will not engage until both the protected trunk ports detect loss of service (LOS).

WID-3281

A software upgrade is in progress. {0} can not proceed during a software upgrade.

Please try again after the software upgrade has completed.

A software upgrade is in progress. The specified operation can not proceed during a software upgrade. Please try again after the software upgrade has completed.

WID-3283

There is a protection switch or another protection operation applied on the ring. Applying this protection operation now will probably cause a traffic outage.

Refer to error message text.

WID-3284

Protection Channel Access circuit found on {0} being set to non-revertive. These circuits will not be able to re-establish after ring or span switch.

OK to continue?

Refer to error message text.

WID-3285

Applying FORCE or LOCKOUT operations may result in traffic loss.

Refer to error message text.

WID-3286

The ring status is INCOMPLETE. CTC cannot determine if there are existing protection operations or switches in other parts of the ring. Applying a protection operation at this time could cause a traffic outage. Please confirm that no other protection operations or switches exist before continuing.

Refer to error message text.

WID-3287

There is a protection operation or protection switch present on the ring. Applying this protection operation now will probably cause a traffic outage.

Refer to error message text.

WID-3288

This ring status is INCOMPLETE. CTC will not be able to apply this change to all of the nodes in the {0}.

Refer to error message text.

WID-3289

This node is provisioned to have No LAN Access. Deleting the last DCC may lead to loss of communication with the node. Continue?

Refer to error message text.