TL1 Alarms and Errors


This chapter provides TL1 alarm and error information supported by the Cisco ONS 15454 and Cisco ONS 15327, including:

Alarms

Conditions

Errors

Echo

Each alarm includes a description and severity. Errors are listed by error type and include error message. Conditions are not alarmed (NA) or not reported (NR) and are listed in the "Conditions" section


Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


7.1  Alarms

Refer to "Alarm Troubleshooting" in the Cisco ONS 15454 Troubleshooting Guide or the Cisco ONS 15327 Troubleshooting Guide for complete alarm definitions, trouble notifications, and fault recovery procedures. The alarms are listed alphabetically by alarmable object:

AEP

AIP

BITS

BP

CC

CKT

DS1

DS3

DWDM Client

DWDM Trunk

ECN

ENV

EQPT

ETHER

EXTSYNCH

FAN

FCMRFUDC

HDGE (G1000)

L2SC (ML-Series)

NBR

NE

NESYNCH

OCN

OSCRING

PWR

STSMON

STSTERM

VCATGROUP

VT-MON

VT-TERM


For a sample of each TL1 alarm that can be generated by the Cisco ONS 15454, refer to the file 15454_r46_tl1_alarms.txt on the Cisco ONS 15454 Software CD in the subdirectory \Tl1. For a sample of each TL1 alarm that can be generated by the Cisco ONS 15327, refer to the file 15327_r46_tl1_alarms.txt on the Cisco ONS 15327 Software CD in the subdirectory \Tl1. These files can be used to test an operations support system's ability to receive alarms which the ONS 15454/ONS 15327 can raise.

7.1.1  AEP

Alarm expansion panel

Table 7-1 AEP  

Alarm
Severity
Description

EQPT

CR/SA

An Equipment Failure alarm indicates that a hardware failure has occurred on the reporting card.

MFGMEM

CR/SA

The manufacturing data memory failure alarm means that the ONS 15454/15327 cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.2  AIP

Auxiliary interface protection module

Table 7-2 AIP 

Alarm
Severity
Description

INVMACADR

MJ/NSA

The Equipment Failure Invalid MAC Address alarm occurs when the ONS 15454/15327 Media Access Control layer address (MAC Address) is invalid.

MEA

CR/SA

If the Mismatch of Equipment Attributes alarm is reported against the AIP, the fuse in the AIP board blew or is missing. The MEA alarm also occurs when an old AIP board with a 2-Amp fuse is installed in a newer 10 Gbps-compatible or ANSI shelf assembly (15454-SA-ANSI).

MFGMEM

CR/SA

The manufacturing data memory failure alarm means that the ONS 15454/15327 cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.3  BITS

Building integration timing supply (BITS) incoming references (BITS-1, BITS-2)

Table 7-3 BITS 

Alarm
Severity
Description

LOF

MJ/SA

A port on the TCC2/MIC BITS input detects a loss of frame (LOF) on the incoming BITS timing reference signal.

LOS

MJ/SA

The TCC2/MIC card has a loss of signal (LOS) condition from the BITS timing source.

SSM-FAIL

MN/NSA

Synchronization status messaging failed.


7.1.4  BP

The backplane

Table 7-4 BP 

Alarm
Severity
Description

MEA

CR/SA

The MEA alarm for the backplane occurs when the revision of the backplane is incompatible with cross-connect equipment.

MFGMEM

CR/SA

The Manufacturing Data Memory Failure (MFGMEM) alarm means that the ONS 15454/15327 cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.5  CC

Control channel

Table 7-5 CC 

Alarm
Severity
Description

LMP-HELLODOWN

MN/NSA

The Link Management Protocol (LMP) Hello Down alarm means that Hello protocol, which monitors unified control plane (UCP) control channel status, is not available for link management.

LMP-NDFAIL

MN/NSA

The LMP Neighbor Detection Fail alarm means that neighbor detection within the UCP has failed.


7.1.6  CKT

UCP circuit

Table 7-6 CKT 

Alarm
Severity
Description

CKTDOWN

CR/SA

The Unified Control Plane (UCP) Circuit Down alarm applies to logical circuits created within the UCP between devices and It occurs when the there is signaling failure across a UCP interface.


7.1.7  DS1

A DS1 line on a DS1 or DS3XM card

Table 7-7 DS1 

Alarm
Severity
Description

LOF

MJ/SA

The DS-1 LOF alarm indicates that the receiving ONS 15454 has lost frame delineation in an incoming DS-1 data stream.

LOS

MJ/SA

A LOS alarm for a DS-3 port or a DS-1 port occurs when the port on the card is in service but no signal is being received.

RCVR-MISS

MJ/SA

A Facility Termination Equipment Receiver Missing alarm occurs when the facility termination equipment detects an incorrect amount of impedance on its backplane connector.

TRMT

MJ/SA

A Missing Transmitter alarm occurs when there is a transmit failure on the DS-1 card because of an internal hardware failure. The card must be replaced.

TRMT-MISS

MJ/SA

A Facility Termination Equipment Transmitter Missing alarm occurs when the facility termination equipment detects an incorrect amount of impedance on its backplane connector.


7.1.8  DS3

A DS3 line on a DS3 or DS3XM card

Table 7-8 DS3 

Alarm
Severity
Description

LOF

CR/SA

The DS-3 LOF alarm indicates that the receiving ONS 15454/15327 has lost frame delineation in the incoming DS-3 data stream.

LOS

CR/SA

A LOS alarm for either a DS-3 port or a DS-1 port occurs when the port on the card is in service but no signal is being received.


7.1.9  DWDM Client

The low-speed port; such as a TXP or MXP, where the optical signal is dropped.

Table 7-9 DWDM Client 

Alarm
Severity
Description

CARLOSS

MJ/SA

A Carrier Loss alarm on the transponder (TXP) or muxponder (MXP) card occurs when G.709 monitoring is turned off at the client port.

EOC

MJ/NSA

The SONET Data Communications Channel (DCC) Termination Failure alarm occurs when the ONS 15454 loses its data communications channel.

GE-OOSYNC

CR/SA

The Gigabit Ethernet Out of Sync alarm object applies to TXP cards when the Gigabit Ethernet signal is out of synchronization and is very similar to the SONET LOS alarm.

HI-LASERBIAS

MN/NSA

The Equipment High Transmit Laser Bias Current alarm is raised against the TXP and MXP card laser performance. The alarm indicates that the card laser has reached the maximum laser bias tolerance.

HI-RXPOWER

MN/NSA

The Equipment High Receive Power alarm is an indicator for TXP card and MXP card received optical signal power. This alarm occurs when the measured optical power of the received signal exceeds the threshold.

HI-TXPOWER

MN/NSA

The Equipment High Transmit Power alarm is an indicator for TXP card and MXP card transmitted optical signal power. This alarm occurs when the measured optical power of the transmitted signal exceeds the threshold.

LOF

CR/SA

The LOF alarm occurs when a port on the reporting OC-N card has an LOF condition. LOF indicates that the receiving ONS 15454 has lost frame delineation in the incoming data.

LO-RXPOWER

MN/NSA

The Equipment Low Receive Power alarm is an indicator for TXP card and MXP card received optical signal power. This alarm occurs when the measured optical power of the received signal falls under the threshold.

LOS

CR/SA

The Loss of Signal for a DWDM client applies to TXP and MXP cards. It is raised when the card port is not receiving input.

LO-TXPOWER

MN/NSA

The Equipment Low Transmit Power alarm is an indicator for TXP card and MXP card transmitted optical signal power. This alarm occurs when the measured optical power of the transmitted signal falls under the threshold.

PORT-CODE-MISM

CR/SA

The Pluggable Port Security Code Mismatch alarm refers to ML-series Ethernet (traffic) cards (MXP and TXP) and occurs when the SFP connector that is plugged into the card is not supported by Cisco.

PORT-COMM-FAIL

CR/SA

The Port Communication Failure alarm applies to TXP and MXP card SFPs and occurs when the card cannot communicate with the SFP.

PORT-MISMATCH

CR/SA

The Pluggable Port Mismatch alarm applies to ML-series Ethernet (traffic) card small form pluggable (SFP) connectors. The alarm indicates that the provisioned payload for the connector does not match the SFP configuration.

PORT-MISSING

CR/SA

The Pluggable Port Missing alarm applies to ML-series Ethernet (traffic) card small form pluggable (SFP) connectors. The alarm indicates that the connector is not plugged into the card port.

SSM-FAIL

MN/NSA

The SSM Failed alarm occurs when the synchronization status messaging received by the ONS 15454 fails.

TIM

CR/SA

The Section Trace Identifier Mismatch (TIM) occurs when the expected J0 path trace string does not match the received string.

TIM-MON

MN/NSA

The TIM Section Monitor Trace Identifier Mismatch alarm is similar to the TIM-P alarm, but it applies to TXP and MXP cards when they are configured in transparent mode.


7.1.10  DWDM Trunk

The optical or DWDM card carrying the high-speed signal.

Table 7-10 DWDM Trunk 

Alarm
Severity
Description

CARLOSS

MJ/SA

A Carrier Loss alarm on the ML-series Ethernet (traffic) card occurs when the Ethernet port has lost its link and is not receiving a valid signal.

DSP-COMM-FAIL

MJ/SA

The DSP Communication Failure alarm indicates that there is a communications failure between an MXP or TXP card microprocessor and the on-board DSP chip that controls the trunk (DWDM) port.

DSP-FAIL

MJ/SA

The DSP Failure alarm indicates that a DSP-COMM-FAIL has persisted for an extended period on an MXP or TXP card and that the card is faulty.

EOC

MJ/NSA

The SONET Data Communications Channel (DCC) Termination Failure alarm occurs when the ONS 15454 loses its data communications channel.

GCC-EOC

MJ/NSA

The GCC Embedded Operation Channel Failure alarm applies to the OTN communication channel for TXP and MXP cards. It is raised when the channel cannot operate.

GE-OOSYNC

CR/SA

The Gigabit Ethernet Out of Sync alarm object applies to TXP cards when the Gigabit Ethernet signal is out of synchronization and is very similar to the SONET LOS alarm.

HI-LASERBIAS

MN/NSA

The Equipment High Transmit Laser Bias Current alarm is raised against the TXP and MXP card laser performance. The alarm indicates that the card laser has reached the maximum laser bias tolerance.

HI-RXPOWER

MN/NSA

The Equipment High Receive Power alarm is an indicator of the optical signal power that is transmitted to the TXP or MXP card.

HI-TXPOWER

MN/NSA

The Equipment High Transmit Power alarm is an indicator for TXP card and MXP card transmitted optical signal power. This alarm occurs when the measured optical power of the transmitted signal exceeds the threshold.

LOC

CR/SA

Loss of Fiber Continuity - Mux 32 occurs when G709 is turned on for trunk ports.

LOF

CR/SA

The Loss of Frame for the DWDM trunk applies to the trunk optical or electrical signal that is carried to TXP and MXP cards.

LOM

CR/SA

The optical transport unit (OTU) Loss of Multiframe alarm applies to MXP and TXP cards when the Multi Frame Alignment Signal (MFAS) overhead field is errored for more than five frames and persists for more than three milliseconds.

LO-RXPOWER

MN/NSA

The Equipment Low Receive Power alarm is an indicator for TXP card and MXP card received optical signal power. This alarm occurs when the measured optical power of the received signal falls under the threshold.

LOS

CR/SA

The Loss of Signal for the DWDM trunk applies to the trunk optical or electrical signal that is carried to TXP and MXP cards.

LO-TXPOWER

MN/NSA

The Equipment Low Transmit Power alarm is an indicator for TXP card and MXP card transmitted optical signal power. This alarm occurs when the measured optical power of the transmitted signal falls under the threshold.

OTUK-LOF

CR/SA

The OTUK LOF alarm applies to TXP cards and MXP cards when G.709 monitoring is enabled for the cards. The alarm indicates that the card has lost frame delineation on the input data. Loss of frame occurs when the optical transport unit overhead frame alignment (FAS) area is errored for more than five frames and that the error persists more than three milliseconds.

PTIM

MN/NSA

The Payload Type Identifier Mismatch alarm occurs when there is a mismatch between the way the G.709 option is configured on MXP cards and TXP card at each end of the optical span.

SSM-FAIL

MN/NSA

The SSM Failed alarm occurs when the synchronization status messaging received by the ONS 15454 fails.

TIM

CR/SA

The Section Trace Identifier Mismatch (TIM) occurs when the expected J0 section trace string does not match the received section trace string.

TIM-MON

MN/NSA

The TIM Section Monitor Trace Identifier Mismatch alarm is similar to the TIM-P alarm, but it applies to TXP and MXP cards when they are configured in transparent mode.

WVL-MISMATCH

MJ/SA

The Equipment Wavelength Mismatch alarm applies to the TXP and MXP cards. It occurs when you provision the card in CTC with a wavelength that the card does not support.


7.1.11  ECN

An EC-N line on an EC-N card

Table 7-11 ECN 

Alarm
Severity
Description

LOF

CR/SA

The EC-N LOF alarm occurs when a port on the reporting OC-N card has an LOF condition.

LOS

CR/SA

LOS on an EC-N port occurs when a SONET receiver detects an all-zero pattern for 10 microseconds or longer.


7.1.12  ENV

An environmental alarm port

Table 7-12 ENV 

Alarm
Severity
Description

EXT

MN/NSA

A Failure Detected External to the NE alarm occurs because an environmental alarm is present, for example, a door is open or flooding has occurred.


7.1.13  EQPT

A card in any of the card slots. This object is used for alarms that refer to the card itself and all other objects on the card including ports, lines, STS and VT.

Table 7-13 EQPT 

Alarm
Severity
Description

AUTORESET

MN/NSA

The Automatic System Reset alarm occurs when you change an IP address or perform any other operation that causes an automatic card-level reboot.

BKUPMEMP

CR/NSA

A problem with the TCC2/XTC card's flash memory.

CARLOSS

MJ/SA

A Carrier Loss on the LAN Equipment alarm occurs when the ONS 15454/15327 and the workstation hosting CTC do not have a TCP/IP connection.

COMIOXC

CR/SA

The I/O Slot To Cross-Connect Communication Failure alarm is caused by the cross-connect card. It occurs when there is a communication failure for a particular I/O slot.

CONTBUS-A

MJ/NSA

The TCC2/XTC card in Slot 7/Slot 5 has lost communication with a traffic card.

CONTBUS-A-18

MJ/NSA

The main processor on the TCC2/XTC card in Slot 7/Slot 5 has lost communication with the coprocessor on the second TCC2/XTC card in Slot 11/Slot 6.

CONTBUS-B

MJ/NSA

The TCC2/XTC card in Slot 11/Slot 6 has lost communication with a traffic card.

CONTBUS-B-18

MJ/NSA

The main processor on the TCC2/XTC card in Slot 11/Slot 6 has lost communication with the coprocessor on the TCC2/XTC card in Slot 7/Slot 5.

CTNEQPT-PBPROT

CR/SA

A failure of the main payload between the protect cross-connect (XC/XCVT/XC10G) card in Slot 10, or the protect XTC card, and the reporting traffic card.

CTNEQPT-PBWORK

CR/SA

A failure of the main payload bus between the active cross-connect (XC/XCVT/XC10G) card in Slot 8, or the active XTC card, and the reporting traffic card.

EQPT

CR/SA

A hardware failure occurred on the reporting card.

ERROR-CONFIG

MN/NSA

The Error in Startup Configuration alarm applies to the ML-series Ethernet cards. These cards process startup configuration files line by line. If one or more lines cannot be executed, the error causes the ERROR-CONFIG alarm.

EXCCOL

MN/NSA

There are too many collisions are occurring between data packets on the network management LAN, and communications between the ONS 15454/15327 and CTC may be affected.

HITEMP

MN/NSA

The High Temperature alarm occurs when the temperature of the ONS 15454 is above 122° F (50° C).

IMPROPRMVL

CR/SA

A card was physically removed from its slot before the card was deleted from CTC.

MEA

CR/SA

The MEA alarm for equipment is reported against a card slot when the physical card inserted into a slot does not match the card type that is provisioned for that slot in CTC.

MEM-GONE

MJ/NSA

Data generated by software operations exceeds the memory capacity of the TCC2/XTC card.

MEM-LOW

MN/NSA

Data generated by software operations is close to exceeding the memory capacity of the TCC2/XTC card.

PEER-
NORESPONSE

MJ/NSA

The switch agent raises a Peer Card Not Responding alarm if either traffic card in a protection group does not receive a response to the peer status request message

PROTNA

MN/NSA

The Protection Unit Not Available is raised by an out-of-service protection when a TCC2/XTC or cross-connect card or port that is provisioned as part of a protection group is not available.

PWR-REDUN

MN/NSA

The Redundant Power Capability Lost alarm applies to cards (such as the TCC2 and newer optical cards) that have two built-in fuses. The alarm indicates that one of the fuses has blown, and must be serviced.

SFTWDOWN

MN/NSA

A Software Download in progress alarm occurs when the TCC2/XTC is downloading or transferring software.

SWMTXMOD

CR/SA

The Switching Matrix Module Failure alarm occurs on the cross-connect card or a traffic card. If the alarm reports against a traffic card, it means that the logic component on the cross-connect card is out of frame (OOF) with the logic component on the reporting traffic card.


7.1.14  ETHER

Ethernet, such as for straight-through (CAT 5) LAN cables.

Table 7-14 ETHER 

Alarm
Severity
Description

CARLOSS

MJ/SA

A Carrier Loss on the LAN E-Series Ethernet (traffic) Card alarm is the data equivalent of an LOS (OC-N). The Ethernet card has lost its link and is not receiving a valid signal.


7.1.15  EXTSYNCH

BITS outgoing references (SYNC-BITS1, SYNC-BITS2)

Table 7-15 EXTSYNCH 

Alarm
Severity
Description

SYNCPRI

MN/NSA

A loss of the primary timing source (reference 1).

SYNCSEC

MN/NSA

A loss of the secondary timing source (reference 2).

SYNCTHIRD

MN/NSA

A loss of the third timing source (reference 3).


7.1.16  FAN

Fan-tray assembly

Table 7-16 FAN 

Alarm
Severity
Description

EQPT-MISS

CR/SA

Indicates the replaceable fan-tray assembly unit is missing or not fully inserted.

FAN

CR/SA

A problem with the fan-tray assembly.

FANDEGRADE

MJ/NSA

The Partial Fan Failure alarm is raised if fan speed for one of the fans in the fan-tray assembly falls below 500 RPM when read by a tachometry counter.

MEA

CR/SA

The MEA alarm is reported against the fan tray when a newer fan-tray assembly (15454-FTA3) with a 5 Amp fuse is used with an older shelf assembly or when an older fan tray with a 2 Amp fuse is used with a newer 10 Gbps compatible or ANSI shelf assembly (15454-SA-ANSI) that contains cards introduced in Release 3.1 or later.

MFGMEM

CR/SA

The manufacturing data memory failure alarm occurs if the ONS 15454 cannot access the data in the erasable programmable read-only memory (EEPROM).


7.1.17  FCMR

Fiber channel

Table 7-17 FCMR 

Alarm
Severity
Description

INC-SIGLOSS

MJ/NSA

The Incoming Signal Loss on the Fibre Channel Interface alarm is raised when there is a signal loss at the local Fibre Channel port.

INC-SYNCLOSS

MJ/NSA

The Incoming Synchronization Loss on the Fibre Channel Interface alarm is raised when there is a synchronization error at the local Fibre Channel port.

TPTFAIL

MJ/SA

The Transport Fail alarm is raised against a local Fiber Channel port when the port receives another SONET error such as AIS-P, LOP-P, UNEQ-P, PLM-P, TIM-P, LOM (for VCat only), or SQM (for VCat only).


7.1.18  FUDC

SONET byte user data channel

Table 7-18 FUDC 

Alarm
Severity
Description

LOS

MN/NSA

The LOS (FUDC) alarm is raised if there is a UDC circuit created on the AIC-I DCC port but the port is not receiving signal input.


7.1.19  HDGE (G1000)

High Density Gigabit Ethernet. Applies to G1000-4 cards.

Table 7-19 HDGE (G1000) 

Alarm
Severity
Description

CARLOSS

MJ/SA

A carrier loss on the LAN G-series card is the data equivalent of an LOS (OC-N) alarm. The Ethernet card has lost its link and is not receiving a valid signal.

TPTFAIL

MJ/SA

The Transport (TPT) Layer Failure alarm for the G-series Ethernet (traffic) cards indicates a break in the end-to-end Ethernet link integrity feature of the G1000-4 cards. TPTFAIL indicates a far-end condition and not a problem with the port reporting TPTFAIL.

TUNDERRUN

MJ/SA

The Ethernet Transmit Underrun alarm is raised by a G1000-4 card when there is a major hardware fault on a port


7.1.20  L2SC (ML-Series)

Layer 2 (and Layer 3 for ML-series) Switching Device

Table 7-20 L2SC 

Alarm
Severity
Description

CARLOSS

MJ/SA

A Carrier Loss alarm on the ML-series Ethernet (traffic) card is the data equivalent of the LOS (OCN) alarm. The Ethernet port has lost its link and is not receiving a valid signal.

TPTFAIL

MJ/SA

The TPT Layer Failure alarm for the ML-series Ethernet (traffic) cards indicates a break in the end-to-end POS link integrity feature of the ML-series POS cards. TPTFAIL indicates a far-end condition or misconfiguration of the POS port.


7.1.21  NBR

Neighbor

Table 7-21 NBR 

Alarm
Severity
Description

RSVP-HELLODOWN

MN/NSA

The Resource Reservation Protocol (RSVP) Hello Down alarm occurs when the Hello protocol, which monitors UCP control channel status, is not available for reserving resources.


7.1.22  NE

The entire network element

Table 7-22 NE 

Alarm
Severity
Description

APC-DISABLED

MJ/NSA

The Automatic Power Control (APC) Disabled occurs when the information related to the number of channels is not reliable.

APC-FAIL

MJ/NSA

The APC Failure alarm occurs when APC has not been able to create a setpoint on a node because it has consumed all allocated power margins.

DATAFLT

MN/NSA

The TCC2/XTC exceeds its flash memory.

DBOSYNC

MJ/NSA

The standby TCC2/XTC "To be Active" database does not synchronize with the "Active" database on the active TCC2/XTC.

DUP-IDADDR

MJ/NSA

The Duplicate IP Address alarm indicates that the alarmed node's IP address is already in use within the same DCC area.

DUP-NODENAME

MJ/NSA

The Duplicate Node Name alarm indicates that the alarmed node's alphanumeric name is already being used within the same DCC area.

HITEMP

CR/SA

The High Temperature alarm occurs when the temperature of the ONS 15454/15327 is above 122° F (50° C).

OPTNTWMIS

MJ/NSA

The Optical Network Type Mismatch alarm is raised when DWDM nodes are not configured for the same type of network, either MetroCore and MetroAccess.

SNTP-HOST

MN/NSA

The SNTP (Simple Network Timing Protocol) Host Failure alarm indicates that an ONS node serving as an IP proxy for the other ONS nodes in the ring is not forwarding SNTP information to the other ONS nodes in the network.

SYSBOOT

MJ/SA

New software is booting on the TCC2/XTC card.


7.1.23  NESYNCH

Represents the timing status of the NE

Table 7-23 NESYNCH 

Alarm
Severity
Description

FSTSYNC

MN/NSA

A Fast Start Synchronization alarm occurs when the ONS node is choosing a new timing reference.

HLDOVRSYNC

MJ/SA

A loss of primary or secondary timing reference.

SYNCPRI

MN/NSA

A loss of the primary timing source (reference 1).

SYNCSEC

MN/NSA

A loss of the secondary timing source (reference 2).

SYNCTHIRD

MN/NSA

A loss of the third timing source (reference 3).


7.1.24  OCN

An OC-N line on an OC-N card

Table 7-24 OCN 

Alarm
Severity
Description

APSB

MN/NSA

The line terminating equipment detects protection switching byte failure in the incoming automatic protection switching (APS) signal.

APSCDFLTK

MN/NSA

A BLSR is not properly configured.

APSC-IMP

MN/NSA

Invalid K bytes.

APSCINCON

MN/SA

The SONET overhead contains K1/K2 APS bytes that notify receiving equipment, such as the ONS 15454/ONS 15327, to switch the SONET signal from a working to a protect path.

APSCM

MJ/SA

The ONS 15454/ONS 15327 expects a working channel but receives a protection channel.

APSCNMIS

MJ/SA

The source node ID contained in the K2 byte of the APS channel being received is not present in the ring map.

APSMM

MN/NSA

There is a mismatch of the protection switching schemes at the two ends of the span.

AUTOLSROFF

CR/SA

The OC-192 card temperature exceeds 194° F (90 ° C). (ONS 15454)

BLSROSYNC

MJ/SA

The BLSR Out Of Synchronization alarm is caused when you attempt to add or delete a circuit and a node on a working ring loses its DCC connection because all transmit and receive fiber has been removed.

EOC

MJ/NSA

The SONET Data Communications Channel (DCC) Termination Failure alarm occurs when the ONS 15454/15327 loses its data communications channel.

EOC-L

MJ/NSA

The SONET Data Communications Channel (DCC) Termination Failure alarm occurs when the ONS 15454/15327 loses its data communications channel.

E-W-MISMATCH

MJ/SA

Nodes in a ring have an east slot/port misconnected to another east slot/port or a west slot/port misconnected to another west slot/port.

EXTRA-TRAF-
PREEMPT

MJ/SA

An Extra Traffic Preempted alarm occurs on OC-N cards in two-fiber and four-fiber BLSRs because low-priority traffic directed to the protect system has been preempted by a working system protection switch.

FEPRLF

MN/NSA

an APS switching channel SF occurs on the protect card coming into the node.

KBYTE-APS-
CHANNEL-
FAILURE

MN/NSA

The APS Channel Failure alarm is raised when there a span provisioned for different APS channels on each side.

LASEREOL

MN/NSA

The Laser Approaching End of Life alarm applies to TXP and MXP cards and occurs when the laser in the card will need to be replaced.

LOF

CR/SA

A port on the reporting OC-N card or TXP card has an LOF condition.

LOS

CR/SA

A SONET receiver detects an all-zero pattern for 10 microseconds or longer.

SSM-FAIL

MN/NSA

Synchronization status messaging received by the ONS 15454/ONS 15327 fails.


7.1.25  OSCRING

Optical service channel ring

Table 7-25 OSCRING 

Alarm
Severity
Description

RING-ID-MIS

MJ/NSA

(Applicable to DWDM nodes only) The Ring ID Mismatch refers to the ring OSC in APC and occurs when a ring ID does not match other detectable node ring IDs.


7.1.26  PWR

Power

Table 7-26 PWR 

Alarm
Severity
Description

BAT-FAIL

MJ/SA

The Battery Fail alarm occurs when one of the two power supplies (A or B) is not detected.

EHIBATVG

MJ/SA

The Extreme High Voltage Battery alarm occurs in a -48 Vdc environment when a battery lead's input voltage exceeds the extreme high power threshold.

ELWBATVG

MJ/SA

The Extreme Low Voltage Battery alarm occurs in a -48 Vdc environment when the voltage on the battery feeds is extremely low or has been lost, and power redundancy is no longer guaranteed.

HIBATVG

MJ/SA

The High Voltage Battery alarm occurs in a -48 Vdc environment when a battery lead's input voltage exceeds the high power threshold.

LWBATVG

MJ/SA

The Low Voltage Battery alarm occurs in a -48 Vdc environment when a battery lead's input voltage falls below the low power threshold. This threshold, with a default value of -44 Vdc, is user-provisionable.


7.1.27  STSMON

STS alarm detection at the monitor point (upstream from the cross-connect)

Table 7-27 STSMON 

Alarm
Severity
Description

LOP-P

CR/SA

A loss of pointer (LOP) condition at the path level.

PLM-P

CR/SA

A signal label mismatch failure (SLMF).

TIM-P

MN/NSA

The TIM Path alarm occurs when the expected path trace string does not match the received path trace string.

UNEQ-P

CR/SA

An SLMF UNEQ Path alarm occurs when the path does not have a valid sender.


7.1.28  STSTERM

STS alarm detection at termination (downstream from the cross-connect)

Table 7-28 STSTERM 

Alarm
Severity
Description

LOM

CR/SA

The optical transport unit (OTU) Loss of Multiframe is a VCAT member alarm which applies to MXP and TXP cards when the Multi Frame Alignment Signal (MFAS) overhead field is errored for more than five frames and persists for more than three milliseconds.

LOP-P

CR/SA

A loss of pointer (LOP) condition at the path level.

PLM-P

CR/SA

A signal label mismatch failure (SLMF).

SQM

CR/SA

The Sequence Mismatch alarm is a VCAT member alarm that occurs when the expected sequence numbers of VCAT members do not match the received sequence numbers.

TIM-P

CR/SA

The TIM Path alarm occurs when the expected path trace string does not match the received path trace string.

UNEQ-P

CR/SA

An SLMF UNEQ Path alarm occurs when the path does not have a valid sender.


7.1.29  VCATGROUP

VT concatenation

Table 7-29 VCATGROUP 

Alarm
Severity
Description

LOA

CR/SA

The Loss of Alignment on a VCG is a VCAT member alarm that occurs when members of a VCG travel over different paths in the network (due to initial operator provisioning or to protection or restoration events) and the differential delays between the paths cannot be recovered by terminating hardware buffers.


7.1.30  VT-MON

VT1 alarm detection at the monitor point (upstream from the cross-connect)

Table 7-30 VT-MON 

Alarm
Severity
Description

AUTOSW-LOP

MN/SA

The AUTOSW-LOP alarm indicates that automatic path protection switching occurred because of an LOP-V alarm.

AUTOSW-
UNEQ

MN/SA

AUTOSW-UNEQ (VTMON) indicates that an UNEQ-V caused automatic path protection switching to occur.

LOP-V

MJ/SA

The LOP VT alarm indicates a loss of pointer at the VT level.

UNEQ-V

MJ/SA

An SLMF UNEQ VT alarm indicates that the node is receiving SONET path overhead with bits 5, 6, and 7 of the V5 overhead byte all set to zeros.


7.1.31  VT-TERM

VT1 alarm detection at termination (downstream from cross-connect)

Table 7-31 VT-TERM 

Alarm
Severity
Description

LOM

CR/SA

The optical transport unit (OTU) Loss of Multiframe is a VCAT member alarm which applies to MXP and TXP cards when the Multi Frame Alignment Signal (MFAS) overhead field is errored for more than five frames and persists for more than three milliseconds.

LOP-V

MJ/SA

The LOP VT alarm indicates a loss of pointer at the VT level.

PLM-V

MJ/SA

A Payload Label Mismatch VT Layer alarm indicates that the content of the V5 byte in the SONET overhead is inconsistent or invalid.

SQM

MJ/SA

The Sequence Mismatch alarm is a VCAT member alarm that occurs when the expected sequence numbers of VCAT members do not match the received sequence numbers.

UNEQ-V

MJ/SA

An SLMF UNEQ VT alarm indicates that the node is receiving SONET path overhead with bits 5, 6, and 7 of the V5 overhead byte all set to zeroes.


7.2  Conditions

The term "Condition" refers to any problem detected on an ONS 15454 or ONS 15327 shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. A snapshot of all current raised conditions on a node, whether they are reported or not, can be retrieved using the CTC Conditions window or using the RTRV-COND commands. You can see the actual reporting messages for alarms and NA conditions in the CTC History tab. Table 7-32 lists the conditions.

7.2.1  Conditions

Table 7-32 Conditions 

Condition
Description

AIS

Alarm Indication Signal

AIS-L

Alarm Indication Signal - Line

AIS-P

Alarm Indication Signal - Path

AIS-V

Alarm Indication Signal - VT

ALS

Automatic Laser Shutdown

APC-DISABLED

Automatic Power Control Disabled

APC-FAIL

Automatic Power Control Failure

APSB

Byte Failure

APSC-IMP

Improper APS Code

APSCDFLTK

Default K Byte

APSCINCON

Inconsistent APS Code

APSCM

Protection Switching Channel Match Failure

APSCNMIS

Node Id Mismatch

APSIMP

APS Invalid Mode

APSMM

Automatic Protection Switch Mode Mismatch

AS-CMD

Alarms Suppressed By User Command

AS-MT

Alarms Suppressed For Maintenance

AU-LOF

LOF - Administration Unit - Loss of Multi Frame

AUD-LOG-LOSS

Audit Log 100 Percent Full - Oldest records will be lost

AUD-LOG-LOW

Audit Log 80 Percent Full

AUTOLSROFF

Automatic Laser Shutoff Due To High Temperature

AUTORESET

Automatic System Reset

AUTOSW-AIS

Automatic path protection Switch Caused By AIS

AUTOSW-LOP

Automatic path protection Switch Caused By LOP

AUTOSW-PDI

Automatic path protection Switch Caused By PDI

AUTOSW-SDBER

Automatic path protection Switch Caused By SDBER

AUTOSW-SFBER

Automatic path protection Switch Caused By SFBER

AUTOSW-UNEQ

Automatic path protection Switch Caused By UNEQ

BAT-FAIL

Battery Failure

BKUPMEMP

Primary Non-Volatile Backup Memory Failure

BLSROSYNC

BLSR Out Of Sync

CARLOSS

Carrier Loss On The LAN

CKTDOWN

Signaling Unable to setup circuit

CLDRESTART

Cold Restart

COMIOXC

IO Slot To XCON Communication Failure

COMM-FAIL

Plug-in Module Communication Failure

CONTBUS-A-18

TCC A To DCC A Processor Communication Failure

CONTBUS-B-18

TCC B To DCC B Processor Communication Failure

CONTBUS_A

Controller A To Shelf Slot Communication Failure

CONTBUS_B

Controller B To Shelf Slot Communication Failure

CTNEQPT-MISMATCH

Connection Equipment Mismatch

CTNEQPT-PBPROT

Interconnection Equipment Failure - Protect XC Payload Bus

CTNEQPT-PBWORK

Interconnection Equipment Failure - Working XC Payload Bus

DATAFLT

Software Fault - Data Integrity Fault

DBOSYNC

Standby Database Out of Sync

DS3-MISM

DS3 Frame Format Mismatch

DSP-COMM-FAIL

DSP Communication Failure

DSP-FAIL

DSP Failure

DUP-IPADDR

IP address already in use within the same DCC Area

DUP-NODENAME

Node name already in use within the same DCC Area

E-W-MISMATCH

Both Ends Of Fiber Provisioned As East Or Both As West

EHIBATVG

Extreme High Volt

ELWBATVG

Extreme Low Volt

EOC

SDCC Termination Failure

EOC-L

Line DCC Termination Failure

EQPT

Equipment Failure

EQPT-MISS

Replaceable Equipment/Unit is Missing

ERFI-P-CONN

Enhanced Remote Failure Indication - Path - Connectivity

ERFI-P-PAYLD

Enhanced Remote Failure Indication - Path - Payload

ERFI-P-SRVR

Enhanced Remote Failure Indication - Path - Server

ERROR-CONFIG

Error in Startup Config

ETH-LINKLOSS

Rear Panel Ethernet Link Removed

EXCCOL

Excess Collisions On The LAN

EXERCISE-RING-FAIL

Exercise Request on Ring Failed

EXERCISE-RING-REQ

Exercise Request on Ring

EXERCISE-SPAN-FAIL

Exercise Request on Span Failed

EXERCISE-SPAN-REQ

Exercise Request on Span

EXT

Failure Detected External To The NE

EXTRA-TRAF-PREEMPT

Extra Traffic Preempted

FAILTOSW

Failure To Switch To Protection

FAILTOSW-PATH

Failure To Switch To Protection - Path

FAILTOSWR

Failure To Switch To Protection - Ring

FAILTOSWS

Failure To Switch To Protection - Span

FAN

Fan Failure

FANDEGRADE

Partial Fan Failure

FE-AIS

Far End AIS

FE-DS1-MULTLOS

Far End Multiple DS1 LOS Detected On DS3

FE-DS1-NSA

Far End DS1 Equipment Failure - Non Service Affecting

FE-DS1-SA

Far End DS1 Equipment Failure - Service Affecting

FE-DS1-SNGLLOS

Far End Single DS1 LOS

FE-DS3-NSA

Far End DS3 Equipment Failure - Non Service Affecting

FE-DS3-SA

Far End DS3 Equipment Failure - Service Affecting

FE-EQPT-NSA

Far End Common Equipment Failure - Non Service Affecting

FE-EXERCISING-RING

Far End Exercising Ring

FE-EXERCISING-SPAN

Far End Exercising Span

FE-FRCDWKSWPR-RING

Far End Working Facility Forced To Switch To Protection - Ring

FE-FRCDWKSWPR-SPAN

Far End Working Facility Forced To Switch To Protection - Span

FE-IDLE

Far End IDLE

FE-LOCKOUTOFPR-SPAN

Far End Lockout Of Protection - Span

FE-LOF

Far End LOF

FE-LOS

Far End LOS

FE-MANWKSWPR-RING

Far End Manual Switch Of Working Facility To Protection - Ring

FE-MANWKSWPR-SPAN

Far End Manual Switch Of Working Facility To Protection - Span

FEC-MISM

FEC Mismatch

FEPRLF

Far End Protection Line Failure

FORCED-REQ

Forced Switch Request

FORCED-REQ-RING

Forced Switch Request On Ring

FORCED-REQ-SPAN

Forced Switch Request On Span

FRCDSWTOINT

Forced Switch To Internal Clock

FRCDSWTOPRI

Forced Switch To Primary Reference

FRCDSWTOSEC

Forced Switch To Second Reference

FRCDSWTOTHIRD

Forced Switch To Third Reference

FRNGSYNC

Free Running Synchronization Mode

FSTSYNC

Fast Start Synchronization Mode

FULLPASSTHR-BI

Bidirectional Full Pass Through Is Active

GCC-EOC

GCC Termination Failure

GE-OOSYNC

GigaBit Ethernet Out of Sync

HI-LASERBIAS

Equipment High Laser Bias

HI-RXPOWER

Equipment High Rx power

HI-TXPOWER

Equipment High Tx power

HIBATVG

High Volt

HITEMP

High Temperature

HLDOVRSYNC

Holdover Synchronization Mode

I-HITEMP

Industrial High Temperature

IMPROPRMVL

Improper Removal

INC-GFP-OUTOFFRAME

Out Of Frame Detected by GFP Receiver

INC-GFP-SIGLOSS

Client Signal Loss Frames Detected by GFP Receiver

INC-ISD

DS3 Idle Condition

INC-SIGLOSS

Incoming Signal Loss on Fibre Channel Interface

INC-SYNCLOSS

Incoming Synchronization Loss on Fibre Channel Interface

INC_GFP_SYNCLOSS

Client Synchronization Loss Frames Detected by GFP Receiver

INHSWPR

Inhibit Switch To Protect Request On Equipment

INHSWWKG

Inhibit Switch To Working Request On Equipment

INTRUSION-PSWD

Security Intrusion Attempt Detected - See Audit Log

INVMACADR

Invalid MAC Address

IOSCFGCOPY

Ios Config Copy In Progress

KB-PASSTHR

K Bytes Pass Through Is Active

KBYTE-APS-CHANNEL-FAILURE

Kbyte Channel Failure

LAN-POL-REV

Lan Connection Polarity Reversed

LASEREOL

Laser Approaching End of Life

LKOUTPR-S

Lockout Of Protection - Span

LMP-HELLODOWN

LMP Hello FSM to Control Channel down

LMP-NDFAIL

LMP Neighbor Discovery has failed

LO-RXPOWER

Equipment Low Rx power

LO-TXPOWER

Equipment Low Tx power

LOA

Loss of Alignment

LOC

Loss of Channel

LOCKOUT-REQ

Lockout Switch Request On Facility or Equipment

LOCKOUT-REQ-RING

Lockout Switch Request On Ring

LOF

Loss Of Frame

LOM

Loss of Multi-Frame

LOP-P

Loss Of Pointer - Path

LOP-V

Loss Of Pointer - VT

LOS

Loss Of Signal

LPBKCRS

Cross-connect Loopback

LPBKDS1FEAC

DS1 Loopback Due To FEAC Command

LPBKDS1FEAC-CMD

DS1 Loopback Command Sent To Far End

LPBKDS3FEAC

DS3 Loopback Due To FEAC Command

LPBKDS3FEAC-CMD

DS3 Loopback Command Sent To Far End

LPBKFACILITY

Facility Loopback

LPBKTERMINAL

Terminal Loopback

LWBATVG

Low Volt

MAN-REQ

Manual Switch Request

MANRESET

Manual System Reset

MANSWTOINT

Manual Switch To Internal Clock

MANSWTOPRI

Manual Switch To Primary Reference

MANSWTOSEC

Manual Switch To Second Reference

MANSWTOTHIRD

Manual Switch To Third Reference

MANUAL-REQ-RING

Manual Switch Request On Ring

MANUAL-REQ-SPAN

Manual Switch Request On Span

MEA

Mismatch Of Equipment And Attributes

MEM-GONE

Free Memory On Card Near Zero

MEM-LOW

Free Memory On Card Very Low

MFGMEM

Manufacturing Data Memory (EEPROM Failure

NO-CONFIG

No Startup Config

NTWTPINC

Network Topology Incomplete

OCHNC-ACTIV-FAIL

Optical Channel Activation Failure

OCHNC-DEACTIV-FAIL

Optical Channel De-Activation Failure

OCHNC-FAIL

Optical Channel Connection Failure

OCHNC-INC

Optical Channel Incomplete

ODUK-AIS-PM

ODUk: Alarm Indication Signal

ODUK-BDI-PM

ODUk: PM Backward Defect Indication

ODUK-LCK-PM

ODUk: Locked Defect - PM

ODUK-OCI-PM

ODUk: Open Connection Indication

ODUK-SD-PM

ODUk: Signal Degrade

ODUK-SF-PM

ODUk: Signal Failure

ODUK-TIM-PM

ODUk: Trail Trace Identifier Mismatch

OOU-TPT

Out of Use - Transport Failure

OPTNTWMIS

Optical Network Type Mismatch

OTUK-AIS

OTUk: Alarm Indication Signal

OTUK-BDI

OTUk: Backward Defect Indication

OTUK-LOF

OTUk: Loss Of Frame

OTUK-SD

OTUk: Signal Degrade

OTUK-SF

OTUk: Signal Failure

OTUK-TIM

OTUk: Trail Trace Identifier Mismatch

OUT-OF-SYNC

8B10B Out of Sync

PDI-P

Payload Defect Indication - Path

PEER-NORESPONSE

Peer Card Not Responding

PLM-P

Payload Label Mismatch - Path

PLM-V

Signal Label Mismatch Failure - Payload Label Mismatch - VT

PORT-CODE-MISM

Pluggable Port security code mismatch

PORT-COMM-FAIL

Module Communication Failure

PORT-MISMATCH

Pluggable Port rate mismatch

PORT-MISSING

Pluggable Port missing

PRC-DUPID

Duplicate Node ID

PROTNA

Protection Unit Not Available

PTIM

Payload Type Identifier Mismatch

PWR-REDUN

Redundant Power Capability Lost

RAI

Remote Alarm Indication

RCVR-MISS

Facility Termination Equipment - Receiver Missing

RFI

Remote Failure Indication

RFI-L

Remote Failure Indication - Line

RFI-P

One-Bit Remote Failure Indication - Path

RFI-V

Remote Failure Indication - VT

RING-ID-MIS

Ring Id Mismatch

RING-MISMATCH

Far End Of Fiber Is Provisioned With Different Ring ID

RING-SW-EAST

Ring Switch Is Active On The East Side

RING-SW-WEST

Ring Switch Is Active On The West Side

RSVP-HELLODOWN

RSVP Hello FSM to Neighbor down

RUNCFG-SAVENEED

Need to Save Running Config

SD

Signal Degrade

SD-L

BER Threshold Exceeded For Signal Degrade - Line

SD-P

BER Threshold Exceeded For Signal Degrade - Path

SF

Signal Failure

SF-L

BER Threshold Exceeded For Signal Failure - Line

SF-P

BER Threshold Exceeded For Signal Failure - Path

SFTWDOWN

Software Download In Progress

SNTP-HOST

SNTP Host Failure

SPAN-SW-EAST

Span Switch Is Active On The East Side

SPAN-SW-WEST

Span Switch Is Active On The West Side

SQM

Sequence Mismatch

SQUELCH

Ring Is Squelching Traffic

SQUELCHED

Equipment Squelched

SSM-DUS

Do Not Use For Synchronization

SSM-FAIL

Failed To Receive Synchronization Status Message

SSM-LNC

G812 - Local Node Clock traceable

SSM-OFF

Synchronization Status Messages Are Disabled On This Interface

SSM-PRC

G811 - Primary Reference Clock traceable

SSM-PRS

Stratum 1 Primary Reference Source Traceable

SSM-RES

Reserved For Network Synchronization Use

SSM-SDH-TN

G812 - Transit Node Clock traceable

SSM-SETS

G813 - Synchronous Equipment Timing Source traceable

SSM-SMC

SONET Minimum Clock Traceable

SSM-ST2

Stratum 2 Traceable

SSM-ST3

Stratum 3 Traceable

SSM-ST3E

Stratum 3E Traceable

SSM-ST4

Stratum 4 Traceable

SSM-STU

Synchronized - Traceability Unknown

SSM-TNC

Transit Node Clock Traceable

SWMTXMOD

Switching Matrix Module Failure

SWTOPRI

Switch To Primary Reference

SWTOSEC

Switch To Second Reference

SWTOTHIRD

Switch To Third Reference

SYNC-FREQ

Synchronization Reference Frequency Out Of Bounds

SYNCPRI

Primary Synchronization Reference Failure

SYNCSEC

Secondary Synchronization Reference Failure

SYNCTHIRD

Third Synchronization Reference Failure

SYSBOOT

System Reboot

TIM

TIM Section - Trace Identifier Mismatch Failure

TIM-MON

TIM Section Monitor - Trace Identifier Mismatch Failure

TIM-P

STS Path Trace Identifier Mismatch

TPTFAIL

Transport layer failure

TRMT

Transmit Failure

TRMT-MISS

Facility Termination Equipment - Transmitter Missing

TUNDERRUN

Ether tx underrun

TX-AIS

Alarm Indication Signal in TX

TX-RAI

Remote Alarm Indication in TX

UNC-WORD

FEC Uncorrected Word

UNEQ-P

Unequipped - Path

UNEQ-V

Signal Label Mismatch Failure - Unequipped VT

VCG-DEG

VCAT Group Degraded

VCG-DOWN

VCAT Group Down

WKSWPR

Switched To Protection

WTR

Wait To Restore

WVL-MISMATCH

Equipment Wavelength Mismatch


7.3  Errors

Errors may be generated by any command or command response message. You can find errors listed by error code in Table 7-33. The format of an error message is as follows:

SID DATE TIME
M CTAG DENY
<ERRCDE>
/* <ERRMSG> */
;

7.3.1  Errors Listed by Error Code

Error Code SONET Error Messages

Table 7-33 Errors 

Error Code
Error Message

ENEQ

At Least One Equipment Is Not Plugged

 

Communication Failed

 

Control Not Provisioned

 

EnvControl IF Is Not Found

 

Environmental Control Interface Not Found

 

Equipment Must Be Present

 

Equipment Not Found

 

Equipment Not Present

 

Equipment Not Provisioned

 

Internal Communication Error

 

No standby present

 

No standby provisioned

 

Not Equipped

 

Sensor IF Is Not Found

 

Sensor Interface Not Found

 

Standby not in valid state, please wait

IBEX

Extra Datablock

 

Extra parameters

 

Invalid AID Block. Extra Datablock.

 

Invalid Payload Block. Extra Datablock.

ICNV

Cannot Set DCC When G709 Is Enabled

ICNV (continued)

Equipment Does Not Match Request

 

Equipment In Use

 

Invalid Command

 

Operation Not Supported By This Card

 

PM Threshold Type Not Supported

 

PM Type Not Supported

 

Performance Monitoring Type Not Supported

 

Threshold Type Not Supported

 

Trace Not Supported On Protect Trunk Port

IDMS

Data Missing

 

Loopback Type Missing

 

Missing Internal Data

IDNC

Invalid Data

 

Invalid PST Value

 

Invalid SST Value

 

PRI source cannot be INTERNAL when SEC source is not INTERNAL

 

PRI source cannot be INTERNAL when THIRD is not INTERNAL

 

Primary Source Cannot Be INTERNAL When Secondary Source Is Not INTERNAL

 

Primary Source Cannot Be INTERNAL When Third Source Is Not INTERNAL

 

SEC source cannot be INTERNAL when THIRD is not INTERNAL

 

Secondary Source Cannot Be INTERNAL When Third Source Is Not INTERNAL

 

Third source must be INTERNAL

IDNV

2F-BLSR Architecture Does Not Permit Manual/Forced Span Switching

 

AUTO ALS Mode Not Allowed With Digital Wrapper Disabled

 

AUTO Trace Mode Not Allowed

 

Alarm Message Must Be Enclosed Within a Pair of Quotes

 

Alarm Message Required for MISC

 

At least an XC10G XC card is needed for this equipment type

 

Cannot Access DCC

 

Cannot Change Protection Type

IDNV (continued)

Cannot Edit NAME When Regeneration Group Not Present

 

CMDMDE Only Applicable when Creating/Deleting Protection Group

 

Command Not Valid On Protect Card

 

Configuration Does Not Support AUTO ALS Mode

 

DCC Not Supported In Transparent Term Mode

 

DCC is in used

 

Description Cannot Have More Than 64 Characters

 

Description cannot be more than 32 characters

 

Edit FMT on an Invalid Card

 

Edit FMT with an Invalid Data

 

Edit Line Code Failed

 

Edit Line Code on an Invalid Card

 

Equipment Does Not Support CALOPWR

 

Equipment Does Not Support EXPWLEN

 

Equipment Does Not Support Payload Type

 

Equipment Does Not Support RDIRN

 

Equipment Does Not Support Regeneration Group

 

Equipment Does Not Support VOAPWR

 

Equipment Incompatible For Regeneration Group

 

Frame Format Contains Invalid Data

 

Frame Format Not Supported On Equipment

 

GCC Not Supported On CLNT Port

 

High Threshold Should Be Lower Than Extreme High

 

Incompatible Equipment Type For Protection

 

Incompatible Equipment Type

 

Incompatible Protect Slot For Protection

 

Interval Out Of Range

 

Invalid AID For PCA Cross-Connection

 

Invalid Alarm Message

 

Invalid Data For 2F-BLSR

 

Invalid Drop Path

IDNV (continued)

Invalid Equipment Type

 

Invalid Ethernet Frame Size

 

Invalid Expected Path Trace Message

 

Invalid Holdoff Timer Value

 

Invalid Log Name

 

Invalid MONLEV Value

 

Invalid MONTYPE Value

 

Invalid Mac Address

 

Invalid Notification Code

 

Invalid PM Interval

 

Invalid Peer Id

 

Invalid Protect Group Identifier

 

Invalid Protid

 

Invalid Recovery Pulse Width

 

Invalid Reference

 

Invalid Regeneration Group Configuration

 

Invalid Report Interval

 

Invalid Start Time

 

Invalid Switch Type For BLSR

 

Invalid TAP Number

 

Invalid TXCOUNT Or RXCOUNT

 

Invalid Threshold Value Ordering

 

Invalid Time Offset

 

Invalid Trace Level

 

Invalid User Name

 

Invalid area id, format is nnn.nnn.nnn.nnn

 

J0 Section Trace Not Supported In Transparent Term Mode

 

Keyword All Not Allowed

 

Line Code Not Supported

 

Low Threshold Should Be Greater Than Extreme Low

 

Multiple AIDs Not Allowed

IDNV (continued)

Multiple PROTID Not valid

 

Multiple Protection Group Card Slot Identifiers Not Allowed

 

Multiple References Not Allowed

 

Must Provide PROTID for Adding Working Modules

 

Null Userid Or Range In Userid List Not Allowed

 

Number Of Reports Is Negative

 

Only CRS_STS is not supported

 

PRIVLVL Not Allowed When PAGE = 0

 

PRIVLVL Not Allowed Without PAGE, PCND, or TMOUT

 

PRIVLVL Required With PAGE, PCND, Or TMOUT

 

Parameter Not Supported By Payload Type

 

Parameter Not Supported By This Optical Node Type

 

Parameter Not Supported On Protect Trunk Port

 

Payload Type Does Not Support AUTO ALS Mode

 

Payload Type Does Not Support DCC

 

Payload Type Does Not Support OOS-AINS State

 

Payload Type Does Not Support OTN/FEC

 

Payload Type Not Supported

 

Protect Card Does Not Support Protection Type

 

Protect Slot Not Provisioned

 

Protection Group Card Slot Identifier Field Required

 

Protection Group Does Not Exist

 

Protection Group Name Exceeds Maximum Length

 

Regeneration Group Name Exceeds Maximum Length

 

Ring Lockout BLSR Switching Is Not Supported

 

SDCC is in used

 

Span Lockout of Working on BLSR Switching Is Not Supported

 

Switch Type Is Not Allowed On 1+1

 

Tap Out Of Range

 

Term Mode Does Not Support Synchronization/Timing Parameters

 

Threshold Increment Invalid

IDNV (continued)

Threshold Value Out Of Range

 

Trace Level Not Supported By Client Port

 

Trace Level Required

 

Trace Not Supported In Transparent Term Mode

 

Transmitted Path Trace Message not supported

 

Transponder Does Not Support Synchronization/Timing Parameters

 

Unsupported Or Incompatible Termination Mode

 

VOA Out Of Range

 

Value Or Threshold Read Only

IDRG

Difference Value Range Error

 

Invalid DURAL Value

 

Invalid MXINV Value

 

Invalid MXINV or DURAL Value

 

Invalid PAGE Value

 

Invalid PAGE or PCND Value

 

Invalid PCND Value

 

Invalid PINT Value

 

Invalid PJMON Value

 

Invalid POLD Value

 

Invalid TMOUT Value

 

Invalid Threshold Value

 

Invalid UOUT Value

 

Invalid Watermark Value

 

PJMON Out Of Range

IIAC

AID Does Not Match with Requested BLSR Path Type

 

AID PARSE ERROR

 

ALL, Ranging and Grouping Are Not Supported for Hard Reset

 

ALL, Ranging and Grouping Are Not Supported

 

Aid validation failed

 

BLSR Time Slot Mismatch

 

Bad Ring Id

IIAC (continued)

CCT=1WAY Not Allowed For The Card

 

Can Not Create Schedule On Protect Card

 

Cannot Access One Plus One Protect Line

 

Cannot Make Changes To Protect Card

 

Cannot make changes to protect card

 

Cross-Connection Cannot Overlap PCA Boundary

 

Cross-Connection Cannot Use GIGE Ports When In Transponder Mode

 

Cross-connection PathWidth Not Supported by Card

 

DS1 Out of Range

 

EQPT Prot AID parse failed

 

Equipment Can Not Be Provisioned On Low Speed Slot

 

Equipment Does Not Match Request

 

Equipment Does Not Match Request

 

Expected Trace Not Supported On This Card Type

 

Expected Trace String Exceeds Max Length (62)

 

Expected Trace String Exceeds Maximum Length

 

FAC parse failed

 

Incoming Trace Not Supported On This Card Type

 

Incorrect Card Type

 

Input, Invalid Access

 

Invalid AID

 

Invalid DS1 AID

 

Invalid FROM= AID

 

Invalid G1000 Facility Port

 

Invalid Month Or Day

 

Invalid Node Side

 

Invalid NodeId

 

Invalid Operation On Drop AID

 

Invalid PJMON Value

 

Invalid PM Direction parameter

 

Invalid Protect AID Or Working AID

IIAC (continued)

Invalid Protect AID or Working AID

 

Invalid Protect AID

 

Invalid RTO AID

 

Invalid Reference

 

Invalid RingId

 

Invalid Source AID

 

Invalid Source/Destination AID Count For Cross-Connection Type

 

Invalid TAP

 

Invalid TO= AID

 

Invalid TPORT AID

 

Invalid Time

 

Invalid VCG Member Number

 

Invalid Year

 

Invalid fac-n-m input

 

J1 Trace Not Supported On This Card

 

List AID Not Allowed For ALL AID

 

List Or All AID Not Supported

 

Loopback type mismatch

 

LpbkType Does Not Match

 

Multiple AIDs Not Supported

 

Multiple Destination AID Exceeds Limit

 

Multiple Destinations Not Supported By Cross-Connection

 

Multiple Source AID Exceeds Limit

 

Multiple TAP AIDs Not Supported

 

Multiple AIDs Not Allowed

 

No TPORT With ONE-PORT-BI TRANS Mode

 

No TPORT With Removing TRANS Mode

 

Not Allowed On 1+1 Protect Line

 

Not Allowed On BLSR Protect Line

 

Optional AIDs Are Not Supported

 

Ranging and Grouping Are Not Supported for Soft Reset

IIAC (continued)

RingId Does Not Match with AID Number

 

TPORT Must Use The Same Slot As The Aid

 

TPORT Supports Only A Single AID

 

Trace Mode Not Supported On This Card Type

 

Trace Not Supported For Current Configuration

 

Trace Not Supported On This Card Type

 

Trace String Exceeds Maximum Length

 

UPSR Cross-Connections Not Allowed For The Facility Of Data Card

 

Use Of TPORT Argument Requires Use Of TRANS

IICM

Command not implemented yet...

 

Command not supported in this release

 

Input, Invalid Command

 

Input, Invalid MOD1

 

Input, Invalid MOD2

 

Input, Invalid MOD2

 

Input, Invalid VERB

IICT

Invalid Correlation Tag

IIDT

`%xx'Encoding Error In FTP URL Parsing

 

0 sec revertive time not supported

 

2F-BLSR Does Not Support SRVRTV/SRVTM/EASTPROT/WESTPROT Parameters

 

AUTO trace mode not supported

 

Can Not Delete A Schedule Which Does Not Exist

 

Cannot Activate To Older Software

 

Cannot Add And Remove Drops Together

 

Cannot Revert From R2 To R1

 

Cannot Revert To Newer Software

 

Command Already In Progress

 

DEST Incompatible With RFR Type

 

DEST Incompatible With SWDL Type

 

DEST Required For RFBU Type

 

Duplicate BLSR Working/Protect Facilities

IIDT

Duplicate DCC

 

Duplicate Performance Monitoring Schedule

 

Duplicate Schedule

 

Error Adding New Schedule

 

FRCD mode not supported

 

FTTD Is Not Supported. Only Direct File Transfers Are Supported

 

Facility Already in OSC Group

 

File Name Missing In FTP URL

 

Flash Manager Not Active

 

Hostname Missing In FTP URL

 

IOS Config File Too Big

 

Invalid 2 Fiber Blsr Parameter

 

Invalid BLSR Mode

 

Invalid BLSR Protect Facility

 

Invalid BLSR Working Facility

 

Invalid Data Parameter

 

Invalid East work Port

 

Invalid OSC Group Facility

 

Invalid Phase Number

 

Invalid Port In FTP URL

 

Invalid Revertive Time

 

Invalid Software Switch Type

 

Invalid State Value

 

Invalid Type Value In FTP URL. Only 'a', 'i', or 'd' Is Allowed.

 

Invalid West work Port

 

Invalid type= Syntax In FTP URL.

 

Loopback type not supported

 

Mandatory FTP URL Not Provided

 

Maximum Performance Monitoring Schedule Limit Reached

 

Memory Out Of Range

 

Missing/Invalid Destination

IIDT (continued)

Missing/Invalid Source

 

Non-IP Hostname In FTP URL

 

Null Outputs In FTP URL Parsing

 

Number Of Reports Is Negative

 

Only MAINT STATE Supported

 

Only NORM CMD_MODE Is Supported

 

Only OOS PST Is Supported

 

Only OVWRT of YES is Allowed For Uploads

 

Only Port 21 Is Supported

 

Only SWDL Is Supported For The xfertype Argument

 

Only Type `a' Is Supported In The COPY-IOSCFG FTP URL

 

Only Type `i' Is Supported In The COPY-RFILE FTP URL

 

Password Missing In FTP URL

 

Performance Monitoring Schedule Does Not Exist

 

Port Missing In FTP URL

 

Reach Limits Of MAX Schedules Allowed. Can Not Add More

 

SRC Incompatible With RFBU Type

 

SRC Required For RFR Type

 

SRC Required For SWDL Type

 

SWDL Incompatible With RFILE-PKG Aid

 

Software Activate/Revert Failed

 

Software Not Available For Switch

 

The URL Contains Unsafe Characters. Please Encode.

 

Unknown Error Processing FTP URL.

 

Unsupported Locn Value

 

Username Missing In FTP URL

 

ftp:// Missing In FTP URL

IIFM

Invalid AID Block. Invalid Data Format.

 

Invalid Data Format

 

Invalid Password

 

Invalid Payload Block. Invalid Data Format.

IIFM

Invalid User ID

IIPG

Configuration Requires Transparent Termination Mode

 

Equipment Payload Type Incompatible For Regeneration Group

 

Payload Type Requires Transparent Termination Mode

 

Transparent Termination Mode Required For Regeneration Group

IISP

Input, Garbage

IITA

GNE: Input, Invalid Target Identifier

 

Input, Invalid Target Identifier

INUP

EXTRNG Configuration Is Not Supported

 

General Block Unsupported

 

Missing mandatory field

 

NODEID Configuration Is Not Supported

 

RNGID Configuration Is Not Supported

 

RNGMAPAUTO Configuration Is Not Supported

 

RNGWTR Configuration Is Not Supported

IPEX

Duplicate N/V field

 

Invalid Payload Block. Extra Parameters.

 

Invalid Payload Block. Extra Parameters.

IPMS

Invalid AID Block. Missing Mandatory Field.

 

Invalid Payload Block. Missing Mandatory Field.

 

Invalid syntax

 

Missing mandatory field

IPNC

Cannot Change Existing Protection Type

 

Cross-connect Doesn't Have UPSR Path Selector

 

Description Cannot Have More Than 64 Characters

 

Invalid Flow Control Value

 

Invalid Maximum Frame Size

 

Invalid Parameter

 

Invalid Trans Value

 

Parameter Not Valid

 

Parameters Are Not Consistent

IPNV

Parameters Not Compatible

 

AID or Condition Must Be Specified

 

Bad IP Configuration Parameter

 

Bad Parameter

 

Bad Reference

 

Cannot Set Expected Path Trace For Source Path

 

Cannot Set Expected Path Trace In Auto Mode

 

Cannot Set Outgoing Path Trace For Drop Path

 

Cross-Connection Does Not Have UPSR Path Selector

 

Empty parameter

 

Exercise Is Not Allowed On Protected Facility

 

Expected Trace String Exceeds Max Length (62)

 

Facility Does Not Support Montype

 

Far End Loopback Type Not Supported In Current Framing Format

 

Far End Performance Monitoring Values Not Supported

 

Holdoff Timer Not Supported For Non-DRI Cross-Connections

 

INT Not Valid For BITS-OUT

 

Internal-Ip Lookup Failed

 

Internal-Network Nodes Lookup Failed

 

Invalid Clock Source

 

Invalid Condition Type

 

Invalid Default Router Address

 

Invalid IIOP Port number

 

Invalid IP Address

 

Invalid IP Configuration Parameter

 

Invalid IP Mask

 

Invalid MONLEV Value

 

Invalid PM register

 

Invalid Parameter

 

Invalid Payload Block. Empty Parameter.

 

Invalid Report Interval

IPNV (continued)

Invalid SNTP Host Address

 

Invalid Start Time

 

Invalid Switch Command For Synchronization

 

Invalid Switch Type

 

Invalid Threshold Value

 

Invalid why parameter

 

New Source Must Be Specified

 

Node Name Exceeds Maximum Length

 

Number Of Reports Is Negative

 

PM Not Supported

 

Parameter Not Valid

 

Payload Does Not Support Optics Montypes

 

Primary Reference Incompatible With Timing Mode

 

Protection Type Does Not Support Reversion Mode

 

Reference Type Not Supported

 

SPNWTR Parameter Not Supported

 

Secondary Reference Incompatible With Timing Mode

 

Synchronization Source Already Defined For The Slot

 

TMGREF Parameter Not Supported

 

Third Reference Incompatible With Timing Mode

 

Time Period Not Applicable

 

Timing Mode Not Compatible

PICC

AID Required

 

AID does not match this session UID

 

Bad Password Toggling - New Password Same As A Prior Password

 

Can't change own security level

 

Can't login

 

Can't logout if user not logged in

 

Command Not Available To This User Level

 

Command Not Available to this User Level

 

Invalid User Access Privilege Value

PICC (continued)

Invalid User Identifier - Must Conform To TL1 Rules

 

Invalid User Password - Must Conform To TL1 Rules

 

Logout failed

 

Password Must Be Changed Before Continuing

 

Password Recently Changed.

 

Unexpected Default Case

 

Unknown CORBA Exception (Internal Error)

 

Unknown User

 

User Access Privilege Required

 

User Already Exists

 

User Identifier Exceeds Maximum Length Allowed

 

User Not Authorized

 

User Password Required

PIMA

Memory Out Of Range

PIUC

Cannot Delete The Logged In User

 

Cannot Remove The Last Superuser

 

Unauthorized change of PID

 

Unauthorized

 

User Currently Logged Into Another Session

 

User Is Not Superuser

 

User Not Allowed To Change User Access Privilege

 

User Not Allowed To Change User Password

 

User Not Allowed To Disable/Enable Self

 

User Not Allowed To Terminate Self

 

User Not Logged In

RALB

GNE: All ENE Connections in Use

 

Requested DCC In Use

RANB

GNE: No Response from ENE - IENE

RNBY

Software upgrade in progress

RRNG

I/O Slot Out Of Range

 

Invalid Slot Number

RTBY

Connection In Service

 

TAP Already In Use

 

TAP Number In Use

RTEN

Cannot Access VT

 

Cannot Change Access Mode

 

Cannot Set Access Mode

 

Invalid Access Mode

 

Invalid STS TAP Number

 

Invalid TAP AID

 

Invalid TAP Mode

 

Invalid TAP Number

 

Invalid VT TAP Number

 

Requested TAP Does Not Exist

 

Requested Tap Busy

 

TAP Not Found

SAAL

Already Allowed

SAAS

Equipment Already Provisioned

SADC

GNE: ENE is down

 

TAP Not Connected

SADS

Loopback Applied On Cross-connection

SAIN

Already Inhibited

SAIS

Port Already In Service

SAMS

Already In Clear Maintenance State

 

Already In Force Maintenance State

 

Already In Lockout Maintenance State

 

Already In Manual Maintenance State

SAOP

Control Already Operated

 

Control Already Released

 

Control Operated In Mntry

SAOS

Port Already In OOS-AINS

 

Port Already In OOS-MT

SAOS (continued)

Port Already Out Of Service

SAPR

Cannot Provision Regeneration Group When A Protection Group Is Present

SARB

GNE: All Gateways in Use

 

System Memory Exhausted. Retry A Few Seconds Later

SCAT

Connection already in loopback

 

Connection already in roll

 

Connection already in test access

 

Connection is tapped

 

End Point Is Already Connected

 

STS Is Already Connected

 

Test Access Busy

 

VT Is Already Connected

 

Would exceed max number of drops

SDBE

AID Parser Failed

 

Asymmetric VCG Not Supported

 

Bad Parameter

 

Cannot Access Alarms

 

Cannot Access Conditions

 

Cannot Access Controls

 

Cannot Access Date/Time

 

Cannot Access Defaults Description

 

Cannot Access Environmental Settings

 

Cannot Access Equipment

 

Cannot Access Facility

 

Cannot Access IP Configuration

 

Cannot Access Interface

 

Cannot Access Node ID

 

Cannot Access Node Name

 

Cannot Access Object

 

Cannot Access Orderwire

 

Cannot Access Protection Group

SDBE (continued)

Cannot Access Protection State

 

Cannot Access SNMP Ip Addr

 

Cannot Access SNTP Host

 

Cannot Access STS

 

Cannot Access Software Version

 

Cannot Access Synchronization Configuration

 

Cannot Access Timezone

 

Cannot Access Trace Information

 

Cannot Access VT Performance Monitoring Parameters

 

Cannot Access VT

 

Cannot Configure SYNC

 

Cannot Create 1+1 Protection Group

 

Cannot Edit STS

 

Cannot Get Line Information

 

Cannot Get Synchronization Configuration

 

Cannot Set Date When Using SNTP

 

Cannot Set Date

 

Cannot Set IP Configuration

 

Cannot Set Node Name

 

Cannot Set Pointer Justification Monitoring Parameter (PJMON)

 

Cannot Set SNTP Host Configuration

 

Cannot Set Timezone

 

Cannot Soft Reset System

 

Cannot Switch To E2 Byte With Express Orderwire IS

 

Card Type Not Supported

 

DLT prg Failed

 

Delete Protection Group Failed

 

Equipment Not Found

 

Facility Does Not Exist

 

Facility Does Not Match Request

 

Facility Does Not Support Mac Address

SDBE (continued)

Facility Is Not Provisioned

 

Facility Not Provisioned

 

File Transfer In Progress

 

Get Sonet Line Info Failed

 

Getting sonet sync configurations

 

IOS Config Update In Progress

 

IP Configuration Failed

 

Incompatible Parameter Values

 

Incorrect Facility Type

 

Interface Does Not Exist

 

Interface Does Not Support Loopback Type

 

Internal Access Failed

 

Internal Data Base Error

 

Internal Database Error

 

Invalid Command

 

Invalid Cross Connect Type For VCG

 

Invalid DCC

 

Invalid Mondat Format

 

Invalid Montm Format

 

Invalid Performance Monitoring Mode

 

Invalid Protection Group

 

Invalid Time Period

 

Invalid Trace Mode for Card Type

 

LCAS Not Supported By This Card

 

Location Value Invalid

 

Loopback Is Invalid

 

Loopback Port In Service

 

Loopback type not supported

 

Mac Address Not Supported By Payload

 

No such interface

 

Node Name Configuration Failed

SDBE (continued)

Not a Sonet interface

 

Object Not Provisioned

 

Object Not Supported

 

Operation Not Supported On EC1 Interface

 

Operation not supported by this card

 

Path Width Not Supported

 

Path loopback already exists

 

SNTP Configuration Failed

 

STS Not Provisioned

 

Synchronization Configuration Not Available

 

Synchronization Status Messaging(SSM) Not Supported On EC1 Interface

 

Synchronization::Sync not available

 

Used Frame Format Does Not Support Synchronization Status Messaging(SSM)

 

VT Not Provisioned

 

Wrong Facility Type

 

Wrong Interface Type

 

bind failed for sonet gen

 

getActiveRefSource failed

 

getRefSources failed

SDLD

Duplex Unit Locked

SDNA

Active TCC Not Ready

 

Standby TCC Not Ready

SNCC

Cross connection does not exist

 

Path roll does not exist

 

Replace This Message When A SNCC message is needed

SNCN

Bad Quality

 

Cannot Switch To Inferior Reference Source

 

Clock Source Failed

 

Command Not Implemented

 

Cross-Connection Type Not Supported In TL1

 

Invalid Clock Source

SNCN (continued)

Requested Direction Not Supported

 

STS Rate Changing Not Supported

SNNS

Reference Not From Optical Card

SNOS

Cannot Change Card Wavelength With Port(s) Not In OOS State

 

Cannot Change Payload With Port(s) Not In OOS State

 

Cannot Change Termination Mode With Port(s) Not In OOS State

SNPR

Cannot Get Role Of Port

 

Get Port Role Failed

SNVS

Already Switched To Internal Reference Source

 

BLSR East Operation Already Set

 

BLSR West Operation Already Set

 

CCAT Cross Connect Exists

 

Cannot Change Configuration When Port(s) Are Not In OOS State

 

Cannot Change Payload For Protection Group

 

Cannot Change Payload When Port(s) Are DCC Enabled

 

Cannot Change Payload When Port(s) Are Used As A Clock Source

 

Cannot Change Termination Mode When Port(s) Are DCC Enabled

 

Cannot Change Termination Mode When Port(s) Are Used As a Clock Source

 

Cannot Change Termination Mode With Trace Enabled

 

Cannot END an AUTO roll

 

Cannot Edit Facility When Not In OOS State

 

Cannot Operate Loopback In Current Cross-connection State

 

Cannot Operate Loopback In Current State

 

Cannot Provision Regeneration Group When A Protection Switch Operation Is Present

 

Cannot Provision Regeneration Group When Equipment Has Different FEC Settings

 

Cannot Provision Regeneration Group When Equipment Has Different G.709 Settings

 

Cross Connect Exists

 

Facility Not Part Of BLSR

 

Invalid AINS Soak Time

SNVS (continued)

Invalid Admin State

 

Invalid BLSR Element

 

Invalid Clock Source

 

Invalid Equipment State

 

Invalid Transponder Provisioning

 

Loopback Already In Progress

 

Loopback Not In Progress

 

No Switch In Progress

 

No valid roll signal

 

Protection Group Does Not Exist

 

Protection Unit Active

 

Roll condition does not exist

 

Roll is not controlled by TL1

 

Status, Not in Valid State

 

Unable to complete roll

 

VCG Already Created

 

Working Unit Already Active

 

Working Unit Already Standby

SOSE

Unrecognized Message Type

SPFA

Cannot Get Current Card Status

 

Protection Unit Failed Or Missing

 

Status, Protection Unit Failed or Missing

SPLD

Cannot Create 1+1 Protection Group

 

Cannot Delete Equipment

 

Cannot Delete Filler Equipment

 

Cannot Enter Filler Equipment

 

Equipment In Use

 

FTP Task Is Busy

 

Facility Is Busy

 

Protection Unit Locked

SRAC

Invalid Connection Type

 

Path roll does not exist

 

Requested Access Configuration is Invalid

SRCN

Already In Requested Mode

 

Area already exists on lan interface

 

Cannot use backbone area, lan active

 

Requested Condition Already Exists

SROF

1+1 Protection Group Not Found

 

1WAYMON not supported

 

2F BLSR Pool Not Available

 

4F BLSR EastProtect Pool Is Not Available

 

4F BLSR Pool Not Available

 

4F BLSR WestProtect Pool Is Not Available

 

AID Listing Not Allowed

 

ALS Mode Does Not Allow Laser Restart

 

APC System Is Busy

 

Active Flash Not Ready

 

All DCCs In Use

 

BLSR In Use

 

BLSR Pool Not Available

 

BLSR Protect STS Path List Is Empty

 

Can Not Get IOS Config Source Origin

 

Cannot Access 1+1 Line

 

Cannot Access 1+1 Protected Line

 

Cannot Access 2 Fiber BLSR

 

Cannot Access 4 Fiber BLSR East Protection

 

Cannot Access 4 Fiber BLSR West Protection

 

Cannot Access 4F BLSR

 

Cannot Access Alarm Log

 

Cannot Access BLSR 2 Wire Line

 

Cannot Access BLSR 2-Wire Line

SROF (continued)

Cannot Access BLSR

 

Cannot Access Cross-Connection

 

Cannot Access DCC

 

Cannot Access Facility

 

Cannot Access PM Mode

 

Cannot Access Performance Monitoring Statistics

 

Cannot Access Protected Equipment

 

Cannot Access Protection Group Information

 

Cannot Access Protection Group Name

 

Cannot Access Protection Group Reversion Information

 

Cannot Access Reversion Information

 

Cannot Access STS

 

Cannot Access TAP

 

Cannot Access Unprotected Line

 

Cannot Access Unprotected Line

 

Cannot Access VT

 

Cannot Add Equipment

 

Cannot Add Equipment

 

Cannot Change BITS Configuration When Manual Switch Exists

 

Cannot Change Ethernet IP With DHCP Provisioned

 

Cannot Change Ethernet IP With OSPF Provisioned

 

Cannot Change Parameter When Manual Switch Exists

 

Cannot Change Port State When Manual Switch Exists

 

Cannot Change Synchronization Configuration When Manual Switch Exists

 

Cannot Change Timing Reference When Manual Switch Exists

 

Cannot Change XTC Protection Group

 

Cannot Configure SYNC

 

Cannot Create Cross-Connection Between Incompatible Interfaces

 

Cannot Create Protection Group

 

Cannot Create Protection Group with Pre-provisioned Cards when CMDMDE is FRCD

 

Cannot Create TAP On Last VT

SROF (continued)

Cannot Create TAP

 

Cannot Create Y cable Protection

 

Cannot Delete Cross-Connection

 

Cannot Delete Last Drop

 

Cannot Delete Protected Equipment

 

Cannot Delete Protection Group

 

Cannot Delete Protection Group with Cross-Connections on Working Card when CMDMDE is FRCD

 

Cannot Disable DWRAP With FEC Enabled

 

Cannot Disable DWRAP With GCC Enabled

 

Cannot Disable DWRAP. Orderwire Circuit Exists

 

Cannot Disable DWRAP. Y-Cable Protection Exists

 

Cannot Edit Ethernet IP

 

Cannot Edit STS

 

Cannot Enable FEC When G.709 Is Disabled

 

Cannot Enable FEC With DWRAP Disabled

 

Cannot Modify Protect Card

 

Cannot Perform ACO

 

Cannot Provision Equipment

 

Cannot Provision Protection Equipment

 

Cannot Set ALS Mode

 

Cannot Set Bidirectional Protection Group

 

Cannot Set DCC When Digital Wrapper Is Enabled

 

Cannot Set GCC When DWRAP Is Disabled

 

Cannot Set NodeId

 

Cannot Set Payload Type

 

Cannot Set Protection Group Name

 

Cannot Set Protection Group Revertive Behavior

 

Cannot Set RingId

 

Cannot Set Span Revertive Mode Unless 4-Fiber Ring

 

Cannot Set Span Revertive Time In Non-revertive Mode

 

Cannot Set Span Revertive Time Unless 4-Fiber Ring

SROF (continued)

Cannot Set Termination Mode

 

Cannot Set Wave Length

 

Cannot Switch For Specified Connection Type

 

Cannot Switch For Specified Path

 

Cannot Update Synchronization Reference List

 

Cannot modify cross connect right now

 

Cannot roll a non-TL1 circuit

 

Cannot set loopback

 

Command Not Supported

 

Connection is already in roll

 

Connection type error

 

Connection type error

 

Could Not Delete Protection

 

Could not provision area

 

Cross-Connection Creation Failed

 

Cross-Connection Does Not Exist

 

Cross-connection Was Not Found

 

Cross-connection deletion failed

 

DCC Does Not Exist

 

DCC In Use

 

DCC Not In Use

 

DCC Termination Is Required to Set OSPF

 

DWRAP Not Enabled

 

Database Is Busy

 

Element Not Found

 

Element not available

 

Equipment Does Not Match Request

 

Equipment Does Not Support 8B10B Montypes

 

Equipment Does Not Support Cross-connection Loopback

 

Equipment Provisioning Failed

 

Ethernet IP And Default Router IP Subnets Are Different

SROF (continued)

Expected Trace Size Exceeds Trace Format Limit

 

Facility Does Not Support Laser Restart

 

Facility Not Protected

 

Facility Not Provisioned

 

Fail to add RTO

 

Flash Is Busy

 

Generation1 Does Not Support Given Quality Of RES

 

Generic ios config upload failure message

 

Get IOR Failed

 

Host Not In IP Address Format

 

Insufficient Path Width For Cross-Connection

 

Insufficient Path Width For Test Access

 

Internal Database Error

 

Internal Exercise Failure

 

Internal Facility Type Failure

 

Invalid AID

 

Invalid ALS Recovery Interval

 

Invalid ALS Recovery Pulse Width

 

Invalid Control Type (CONTTYPE) For AID

 

Invalid Cross Connect Type For VCG

 

Invalid Cross-Connection Path

 

Invalid Cross-Connection Type For Drops

 

Invalid Drop Path

 

Invalid FTP Username/Password

 

Invalid Loopback Provision

 

Invalid Operation For Connection Type

 

Invalid Operation For Specified Path

 

Invalid Path

 

Invalid Protection Group

 

Invalid Protection Switch Operation

 

Invalid RMODE

SROF (continued)

Invalid SYNC entity

 

Invalid State When Loopback Present

 

Invalid Subnet Mask

 

Invalid Synchronization Source

 

Invalid UPSR Path

 

Invalid type for this Cross connection

 

Is Not 1+1 Element Type

 

J0 Section Trace Level Not Supported By 10GE Payload Type

 

Laser Was Not Shutdown.Cannot Restart Laser

 

Location Incompatible With Loopback Type

 

Loopback Not Allowed On Drop Path

 

Loopback Type Does Not Match

 

MIC Cards Cannot Be Reset

 

Maximum Drop Limit Reached

 

Maximum User Limit Reached

 

Maximum VT Cross Connection Limit Reached

 

No Path To Regulate

 

No Start-Up IOS Config

 

No clock and data copy information from Line cards and CXC cards

 

Node::General not available

 

Node::NetworkConfig not available

 

Non Revertive Mode Does Not Allow to Set RVTM

 

Not Enough Path Width For TACC

 

Number of Drops Exceed Allowable

 

One Plus One Line pool not available

 

Operate Alarm Cutoff Failed

 

Operation Not Supported

 

Operation not Valid for Connection Type

 

Operation not Valid for Path Specified

 

OspfTopology::OSPFTopo not available

 

Parameter Not Supported When DWRAP Is Enabled

SROF (continued)

Path Already In Use

 

Path Specified Is Not Valid

 

Path Used For Test Access

 

Payload Type Does Not Support Trace

 

Peer Equipment Attributes Do Not Match

 

Peer Equipment Type Does Not Match

 

Peer Facility Has Loopback

 

Peer Facility In Use

 

Peer Payload Type Does Not Match

 

Peer Termination Mode Does Not Match

 

Pool Does Not Exist

 

Pool not available

 

Protect Port Active

 

Protection Group Does Not Exist

 

Protection Switching Failed

 

Protection Type Mismatch

 

Protection Type Not Compatible With Facility

 

Provisioning Rules Failed

 

ROLL TO path is already in the cross-connection

 

Regeneration Group Already Exist

 

Regeneration Group Does Not Exist

 

Requested Operation Failed

 

Requested Tap Busy

 

Ring Reversion Failed

 

SDBER Out Of Range

 

SDCC creation failed

 

SFBER Out Of Range

 

SSet PRG Reversion Failed

 

STS Does Not Exist

 

STS Does Not Have TAP

 

STS Path Width Does Not Match

SROF (continued)

STS Path Width Does Not Match

 

STS Rates Do Not Match

 

Section Termination Mode Not Supported

 

Security::General not available

 

Set PRG Bidirectional Failed

 

Set PRG Name Failed

 

Software Activation Failed

 

Software Download Failed

 

Software Error

 

Software Reversion Failed

 

Span Reversion Failed

 

Specified Operation Is Not Valid

 

Standby Flash Not Ready

 

Sync Reference List Update Failed

 

Synchronization/Timing Parameters Not Supported With DWRAP Enabled

 

TAP connected

 

TTI Trace Not Allowed With G709 Disabled

 

Tap Not Provisioned

 

Test Access Active

 

Test Access Not Supported On Card

 

Trace Format Not Supported By J0 Section Trace

 

Trace Format Not Supported By TTI Section Trace

 

Trace Message Size Exceeds Trace Format Limit

 

Trace Mode Incompatible With Termination Mode

 

Trace Mode Not Supported

 

UPSR Needed To Change Revertive Behavior

 

Unable to cancel roll

 

Unknown Internal Error

 

Unprotected Line pool not available

 

Unprovisioning Rules Failed

 

Unsupported BLSR STS Path Operation

SROF (continued)

Unsupported Command Type

 

Unsupported Element Type

 

VCG Does Not Exist

 

VT Cross-Connection Does Not Exist

 

VT Does Not Exist

 

VT Does Not Have TAP

 

VT Path Width Does Not Match

 

Wavelength Value Not Supported

 

Working/Peer Card In Use

 

Wrong Interface Type

 

XC Card Does Not Support VT Cross-Connection

 

XC Card Not Present

 

XCVXL Card Not Present

 

Y-Cable Protection Does Not Exist

SRQN

BLSR Creation Failed

 

BLSR Deletion Failed

 

BLSR Does Not Exist

 

BLSR Editing Failed

 

Cannot Create Automatic Links

 

Cannot Edit SENDDUS On Protect Port

 

Cannot Edit SYNCMSG On Protect Port

 

DCC Not Allowed On Protect Port

 

DCC not enabled

 

Data Access Request Failed

 

Invalid Mode For Current Configuration

 

Invalid Request

 

OSC Group Already Exists

 

OSC Group Does Not Exist

 

Path loopback already exists

 

Protect Card Does Not Support Electrical Protection

 

Protect Card Does Not Support Protection Type

SRQN (continued)

STS Cross-Connection Does Not Exist

 

VT Cross-Connection Does Not Exist

SRTN

TAP Not Found

SSRD

Manual Switch Cannot Override Forced Switch

 

Switch Request Denied

SSRE

GNE: ENE Connection Closed

 

GNE: System Resources Exceeded - FD

 

GNE: System Resources Exceeded - Lock

 

GNE: System Resources Exceeded - Thread

 

Memory Resources Exceeded

 

Memory resource denial

SWFA

Status, Working Unit Failed or Missing

 

Working Unit Failed Or Missing

SWLD

Working Unit Locked


7.4  Echo

In order to improve telnet functionality for automated systems, the echo function has been turned off since ONS 15454 Release 3.0. This change is transparent to users running standard UNIX-compliant telnet clients; however, PC users may need to change their client setup to enable "local echo." This is normally accomplished by a pull-down menu or a preference attribute.

To test the local echo on your PC client, use the RTRV-HDR command. If you receive a response but no data, set local echo ON. Cisco recommends that you close any windows containing sensitive information after exiting a TL1 session.