Error Messages
Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This chapter lists the Cisco ONS 15454, 15454 SDH, 15600, 15327 and 15310 error messages. Table 3-1 gives a list of all error message numbers, the messages, and a brief description of each message. The table lists two types of messages: error messages (EID-nnnn) and warning messages (WID-nnnn). Error messages are alerts that an unexpected or undesirable operation has occurred which either indicates the risk of loss of traffic or an inability to properly manage devices in the network. Warnings are alerts that the requested operation could lead to an error. Warnings are sometimes used to convey important information.
The error dialog box in Figure 3-1 consists of three parts: the error title, error ID, and the error message.
Figure 3-1 Error Dialog Box
|
|
|
---|---|---|
EID-0 |
Invalid error ID. |
The error ID is invalid. |
EID-1 |
Null pointer encountered in {0}. |
Cisco Transport Controller (CTC) encountered a null pointer in the area described by the specified item. |
EID-1000 |
The host name of the network element cannot be resolved to an address. |
Refer to error or warning message text. |
EID-1001 |
Unable to launch CTC due to applet security restrictions. Please review the installation instructions to make sure that the CTC launcher is given the permissions it needs. Note that you must exit and restart your browser in order for the new permissions to take effect. |
Refer to error or warning message text. |
EID-1002 |
The host name (e.g., for the network element) was successfully resolved to its address, but no route can be found through the network to reach the address. |
Refer to error or warning message text. |
EID-1003 |
An error was encountered while attempting to launch CTC. |
Unexpected exception or error while launching CTC from the applet. |
EID-1004 |
Problem Deleting CTC Cache: {0} {1} |
CTC encountered a problem deleting the cache. |
EID-1005 |
An error occurred while writing to the {0} file. |
CTC could not write the launching batch file. |
EID-1006 |
The URL used to download {0} is malformed. |
The URL used to download the Launcher.jar file is malformed. |
EID-1007 |
An I/O error occurred while trying to download {0}. |
An input or output exception was encountered when CTC tried to download the GUI launcher. |
EID-1018 |
Password must contain at least 1 alphabetic, 1 numeric, and 1 special character (+, # or %). |
The password is invalid. |
EID-1019 |
Could not create {0}. |
CTC could not create the file due to an invalid filename. |
EID-1020 |
Fatal exception occurred, exiting CTC. |
CTC was unable to switch from the node or card view to the network view, and is now shutting down. |
EID-1021 |
Unable to navigate to {0}. |
Failed to display the indicated view—node or network. |
EID-1022 |
A session cannot be opened right now with this slot. Most likely someone else (using a different CTC) already has a session opened with this slot. |
Refer to error or warning message text. |
EID-1023 |
This session has been terminated. This can happen if the card resets, the session has timed out, or if someone else (possibly using a different CTC) already has a session open with this slot. |
Refer to error or warning message text. |
EID-1025 |
Unable to create Help Broker. |
CTC was unable to create the help broker for the online help. |
EID-1026 |
Unable to locate HelpSet. |
CTC was unable to locate the help set for the online help. |
EID-1027 |
Unable to locate Help ID: {0} |
CTC was unable to locate the help ID for the online help. |
EID-1028 |
Error saving table. {0} |
There was an error saving the specified table. |
EID-1031 |
CTC cannot locate the online user manual files. The files may have been moved, deleted, or not installed. To install online user manuals, run the CTC installation wizard on the software or documentation CD. |
Refer to error or warning message text. |
EID-1032 |
CTC cannot locate Acrobat Reader. If Acrobat Reader is not installed, you can install the Reader using the CTC installation wizard provided on the software or documentation CD. |
Refer to error or warning message text. |
EID-1034 |
Unable to locate HelpSet when searching for Help ID "{0}". |
CTC is unable to locate the subset {0} of the context sensitive help files. |
EID-1035 |
CTC experienced an I/O error while working with the log files. Usually this means that the computer has run out of disk space. This problem may or may not cause CTC to stop responding. Ending this CTC session is recommended, but not required. |
Refer to error or warning message text. |
WID-1036 |
WARNING: Deleting the CTC cache may cause any CTC running on this system to behave in an unexpected manner. |
Refer to error or warning message text. |
EID-1037 |
Could not open {0}. Please enter another filename. |
Refer to error or warning message text. |
EID-1038 |
The file {0} does not exist. |
Refer to error or warning message text. |
EID-2001 |
No rolls selected. {0} |
No rolls were selected for the bridge and roll. |
EID-2002 |
The Roll must be completed or cancelled before it can be deleted. |
You cannot delete the roll unless it has been completed or canceled. |
EID-2003 |
Error deleting roll. |
There was an error when CTC tried to delete the roll. |
EID-2004 |
No IOS slot selected. |
You did not select a Cisco IOS slot. |
EID-2005 |
CTC cannot find the online help files for {0}. The files may have been moved, deleted, or not installed. To install online help, run the setup program on the software or documentation CDs. |
CTC cannot find the online help files for the specified window. The files might have been moved, deleted, or not installed. To install online help, run the setup program on the software or documentation CDs. |
EID-2006 |
Error editing circuit(s). {0} {1}. |
An error occurred when CTC tried to open the circuit for editing. |
EID-2007 |
Unable to save preferences. |
CTC cannot save the preferences. |
EID-2008 |
Unable to store circuit preferences: {0} |
CTC cannot find the file needed to save the circuit preferences. |
EID-2009 |
Unable to download package: |
Refer to error or warning message text. |
EID-2010 |
Delete destination failed. |
CTC could not delete the destination. |
EID-2011 |
Circuit destroy failed. |
CTC could not destroy the circuit. |
EID-2012 |
Reverse circuit destroy failed. |
CTC could not reverse the circuit destroy. |
EID-2013 |
Circuit creation error. Circuit creation cannot proceed due to changes in the network which affected the circuit(s) being created. The dialog will close. Please try again. |
Refer to error or warning message text. |
EID-2014 |
No circuit(s) selected. {0} |
You must select a circuit to complete this function. |
EID-2015 |
Unable to delete circuit {0}as it has one or more rolls. |
CTC cannot delete the circuit because it contains one or more rolls. |
EID-2016 |
Unable to delete circuit. |
There was an error deleting the circuit. |
EID-2017 |
Error mapping circuit. {0} |
There was an error mapping the circuit. |
EID-2018 |
Circuit roll failure. The circuit has to be in the DISCOVERED state in order to perform a roll. |
Refer to error or warning message text. |
EID-2019 |
Circuit roll failure. Current version of CTC does not support bridge and roll on a VT tunnel or VT aggregation point circuit. |
Refer to error or warning message text. |
EID-2020 |
Circuit roll failure. The two circuits must have the same direction. |
Refer to error or warning message text. |
EID-2021 |
Circuit roll failure. The two circuits must have the same size. |
Refer to error or warning message text. |
EID-2022 |
Circuit roll failure. A maximum of two circuits can be selected for a bridge and roll operation. |
Refer to error or warning message text. |
EID-2023 |
Unable to create new user account. |
Refer to error message text. |
EID-2024 |
Node selection error. |
There was an error during node selection. |
EID-2025 |
This feature cannot be used. Verify that each of the endpoints of this circuit are running software that supports this feature. |
Refer to error or warning message text. This error is generated from the AnsOpticsParamsPane to indicate that the selected ring type is not supported by the endpoints of the circuit. In the VLAN tab it indicates that the back-end spanning tree protocol (STP) disabling is not supported. |
EID-2026 |
Unable to apply UPSR request. {0} |
Error occurred while attempting to switch a path protection circuit away from a span. |
EID-2027 |
Error deleting circuit drop. |
CTC could not delete the circuit drop. |
EID-2028 |
Error removing circuit node. |
CTC could not remove the circuit node. |
EID-2029 |
The requested operation is not supported. |
The task you are trying to complete is not supported by CTC. |
EID-2030 |
Provisioning error. |
There was an error during provisioning. |
EID-2031 |
Error adding node. |
There was an error while adding a node. |
EID-2032 |
Unable to rename circuit. {0} |
CTC could not rename the circuit. |
EID-2033 |
An error occurred during validation. {0} |
There was an internal error while validating the user changes after the Apply button was pressed. This error can occur in the Edit Circuit dialog box or in the BLSR table in the shelf view (rare condition). |
EID-2034 |
Unable to add network circuits: |
Refer to error or warning message text. |
EID-2035 |
The source and destination nodes are not connected. |
Refer to error or warning message text. |
EID-2036 |
Cannot delete this {0}. |
Refer to error or warning message text. |
EID-2037 |
Application error. Cannot find attribute for {0}. |
CTC cannot find an attribute for the specified item. |
EID-2038 |
Invalid protection operation. |
There was an invalid protection operation. |
EID-2040 |
Please select a node first. |
You must select a node before performing the task. |
EID-2041 |
No paths are available on this link. Please make another selection. |
Refer to error or warning message text. |
EID-2042 |
This span is not selectable. Only the green spans with an arrow may be selected. |
Refer to error or warning message text. |
EID-2043 |
This node is not selectable. Only the source node and nodes attached to included spans (blue) are selectable. Selecting a selectable node will enable its available outgoing spans. |
Refer to error or warning message text. |
EID-2044 |
This link may not be included in the required list. Constraints only apply to the primary path. Each node may have a maximum of one incoming signal and one outgoing link. |
Refer to error or warning message text. |
EID-2045 |
This link may not be included in the required list. Only one outgoing link may be included for each node. |
Refer to error or warning message text. |
EID-2047 |
Error validating slot number. Please enter a valid value for the slot number. |
Refer to error or warning message text. |
EID-2048 |
Error validating port number. Please enter a valid value for the port number. |
Refer to error or warning message text. |
EID-2050 |
New circuit destroy failed. |
CTC could not destroy the new circuit. |
EID-2051 |
Circuit cannot be downgraded. {0} |
The specified circuit cannot be downgraded. |
EID-2052 |
Error during circuit processing. |
There was an error during the circuit processing. |
EID-2054 |
Endpoint selection error. |
There was an error during the endpoint selection. |
EID-2055 |
No endpoints are available for this selection. Please make another selection. |
This error occurs in the circuit creation dialog only during a race condition that has incorrectly allowed entities without endpoints to be displayed in the combo boxes. |
EID-2056 |
Communication error. {0} |
An internal error occurred while synchronizing alarms with the nodes. Network Alarm tab. |
EID-2059 |
Node deletion Error. {0} |
There was an error during the node deletion. |
EID-2060 |
No PCA circuits found. |
CTC could not find any protection channel access (PCA) circuits for this task. |
EID-2061 |
Error provisioning VLAN. |
There was an error defining the VLAN. |
EID-2062 |
Cannot delete VLAN. No VLAN(s) are selected. Please select a VLAN. |
Cannot delete VLAN. No VLAN(s) are selected. Please select a VLAN. |
EID-2063 |
Cannot delete default VLAN. |
The selected VLAN is the default VLAN, and cannot be deleted. |
EID-2064 |
Error deleting VLANs. |
There was an error deleting the VLAN. |
EID-2065 |
Cannot import profile. Profile "{0}" exists in the editor and the maximum number of copies (ten) exists in the editor. Aborting the import. The profile has already been loaded eleven times. |
Cannot import profile. The specified profile exists in the editor and the maximum number of copies (ten) exists in the editor. Aborting the import. The profile has already been loaded eleven times. |
EID-2066 |
Unable to store profile. Error writing to {0}. |
CTC encountered an error while trying to store the profile. |
EID-2067 |
File write error. {0} |
CTC encountered a file write error. |
EID-2068 |
Unable to load alarm profile from node. |
CTC encountered an error trying to load the alarm profile from the node. |
EID-2069 |
File not found or I/O exception. {0} |
Either the file was not found, or there was an input/output exception. |
EID-2070 |
Failure deleting profile. {0} |
The profile deletion failed. |
EID-2071 |
Only one column may be highlighted. |
Refer to error or warning message text. |
EID-2072 |
Only one profile may be highlighted. |
Refer to error or warning message text. |
EID-2073 |
This column is permanent and may not be removed. |
Refer to error or warning message text. |
EID-2074 |
Select one or more profiles. |
Refer to error or warning message text. |
EID-2075 |
This column is permanent and may not be reset. |
Refer to error or warning message text. |
EID-2077 |
This column is permanent and may not be renamed. |
Refer to error or warning message text. |
EID-2078 |
At least two columns must be highlighted. |
Refer to error or warning message text. |
EID-2079 |
Cannot load alarmables into table. There are no reachable nodes from which the list of alarmables may be loaded. Please wait until such a node is reachable and try again. |
Refer to error or warning message text. |
EID-2080 |
Node {0} has no profiles. |
The specified node does not have any profiles. |
EID-2081 |
Error removing profile {0} from node {1}. |
There was an error removing the specified profile from the node. |
EID-2082 |
Cannot find profile {0} on node {1}. |
CTC cannot find the specified profile from the specified node. |
EID-2083 |
Error adding profile {0} to node {1}. |
There was an error adding the specified profile to the specified node. |
EID-2085 |
Invalid profile selection. No profiles were selected. |
Refer to error or warning message text. |
EID-2086 |
Invalid node selection. No nodes were selected. |
Refer to error or warning message text. |
EID-2087 |
No profiles were selected. Please select at least one profile. |
Refer to error or warning message text. |
EID-2088 |
Invalid profile name. |
Refer to error or warning message text. |
EID-2089 |
Too many copies of {0} exist. Please choose another name. |
Too many copies of the specified item exist. |
EID-2090 |
No nodes selected. Please select the node(s) on which to store the profile(s). |
Refer to error or warning message text. |
EID-2091 |
Unable to switch to node {0}. |
CTC is unable to switch to the specified node. |
EID-2092 |
General exception error. |
CTC encountered a general exception error while trying to complete the task. |
EID-2093 |
Not enough characters in name. {0} |
There are not enough characters in the name. |
EID-2094 |
Password and confirmed password fields do not match. |
You must make sure the two fields have the same password. |
EID-2095 |
Illegal password. |
The password you entered is not allowed. |
EID-2096 |
The user must have a security level. |
You must have an assigned security level to perform this task. |
EID-2097 |
No user name specified. |
You did not specify a user name. |
EID-2099 |
Ring switching error. |
There was an error during the ring switch. |
EID-2100 |
Please select at least one profile to delete. |
Refer to error or warning message text. |
EID-2101 |
Protection switching error. |
There was an error during the protection switch. |
EID-2102 |
The forced switch could not be removed for some circuits. You must switch these circuits manually. |
The forced switch could not be removed for some circuits. You must switch these circuits manually. |
EID-2103 |
Error upgrading span. |
There was an error during the span upgrade. |
EID-2104 |
Unable to switch circuits back as one or both nodes are not reachable. |
This error occurs during the path protection span upgrade procedure. |
EID-2106 |
The node name cannot be empty. |
You must supply a name for the node. |
EID-2107 |
Error adding {0}, unknown host. |
There was an error adding the specified item. |
EID-2108 |
{0} is already in the network. |
The specified item is already in the network. |
EID-2109 |
The node is already in the current login group. |
Refer to error or warning message text. |
EID-2110 |
Please enter a number between 0 and {0}. |
You must enter a number in the range between 0 and the specified value. |
EID-2111 |
This node ID is already in use. Please choose another. |
Refer to error or warning message text. |
EID-2113 |
Cannot set extension byte for ring. |
CTC cannot set the extension byte. |
EID-2114 |
Card communication failure. Error applying operation. |
This error can occur during an attempt to apply a BLSR protection operation to a line. |
EID-2115 |
Error applying operation. |
There was an error applying the specified operation. |
EID-2116 |
Invalid extension byte setting. |
The extension byte set is invalid. |
EID-2118 |
Cannot delete ring. There is a protection operation set. All protection operations must be clear for ring to be deleted. |
Refer to error or warning message text. |
EID-2119 |
Cannot delete {0} because a protection switch is in effect. Please clear any protection operations, make sure that the reversion time is not "never" and allow any protection switches to clear before trying again. |
Refer to error or warning message text. |
EID-2120 |
The following nodes could not be unprovisioned |
The specified nodes could not be unprovisioned. |
EID-2121 |
Cannot upgrade ring. |
CTC cannot upgrade the ring. |
EID-2122 |
Inadequate ring speed for upgrade. Only {0} (or higher) {1} can be upgraded to 4-fiber. |
You have selected an incorrect ring speed for upgrade. Only rings within the specified parameters can be upgraded to 4-fiber BLSR. |
EID-2123 |
Verify that the following nodes have at least two in-service ports with the same speed as the 2-fiber {0}. The ports cannot serve as a timing reference, and they cannot have DCC terminations or overhead circuits. {1} |
Nonupgradable nodes. Verify that the specified nodes have at least two IS-NR ports with the same speed as the 2-fiber BLSR. |
EID-2124 |
You cannot add this span because it is connected to a node that already has the east and west ports defined. |
Refer to error or warning message text. |
EID-2125 |
You cannot add this span as it would cause a single card to host both the east span and the west span. A card cannot protect itself. |
Refer to error or warning message text. |
EID-2126 |
OSPF area error. {0} |
There is an Open Shortest Path First (OSPF) area error. |
EID-2127 |
You cannot add this span. It would cause the following circuit(s) to occupy different STS regions on different spans. |
Refer to error or warning message text. |
EID-2128 |
Illegal state error. |
An internal error occurred while trying to remove a span from a BLSR. This alarm occurs in the network-level BLSR creation dialog box. |
EID-2129 |
This port is already assigned. The east and west ports must be different. |
Refer to error or warning message text. |
EID-2130 |
The ring ID value, {0}, is not valid. Please enter a valid number between 0 and 9999. |
Refer to error or warning message text. |
EID-2131 |
Cannot set reversion to INCONSISTENT. |
You must select another reversion type. |
EID-2135 |
I/O error. Unable to store overhead circuit preferences. {0} |
Input/Output error. Unable to store overhead circuit preferences. |
EID-2137 |
Circuit merge error. {0} |
There was an error merging the circuits. |
EID-2138 |
Cannot delete all destinations. Please try again. |
Refer to error or warning message text. |
EID-2139 |
Error updating destinations. |
There was an error updating the circuit destinations. |
EID-2143 |
No online help version selected. Cannot delete the online help book. |
You cannot delete the online help. |
EID-2144 |
Error deleting online help book(s). |
You cannot delete the online help. |
EID-2145 |
Unable to locate a node with an IOS card. |
Unable to locate a node with a Cisco IOS card. |
EID-2146 |
Security violation. You may only logout your own account. |
Refer to error or warning message text. |
EID-2147 |
Security violation. You may only change your own account. |
Refer to error or warning message text. |
EID-2148 |
Security violation. You may not delete the account under which you are currently logged in. |
Refer to error or warning message text. |
WID-2149 |
There is nothing exportable on this view. |
Refer to error or warning message text. |
WID-2150 |
Node {0} is not initialized. Please wait and try again. |
Refer to error or warning message text. |
WID-2152 |
Spanning tree protection is being disabled for this circuit. |
Refer to error or warning message text. |
WID-2153 |
Adding this drop makes the circuit a PCA circuit. |
Refer to error or warning message text. |
WID-2154 |
Disallow creating monitor circuits on a port grouping circuit. |
Refer to error or warning message text. |
WID-2155 |
Only partial switch count support on some nodes. |
Refer to error or warning message text. |
WID-2156 |
Manual roll mode is recommended for dual rolls. For auto dual rolls, please verify that roll to facilities are in service and error free. |
Refer to error or warning message text. |
WID-2157 |
Cannot complete roll(s). |
CTC cannot complete the roll(s). |
EID-2158 |
Invalid roll mode. |
The selected roll mode is invalid. |
EID-2159 |
Roll not ready for completion. |
The roll is not ready for completion. |
EID-2160 |
Roll not connected. |
The selected roll is not connected. |
EID-2161 |
Sibling roll not complete. |
The sibling roll is not complete. |
EID-2162 |
Error during roll acknowledgement. |
There was an error during the roll acknowledgement. |
EID-2163 |
Cannot cancel roll. |
CTC cannot cancel the roll. |
EID-2164 |
Roll error. |
CTC encountered a roll error. |
WID-2165 |
The MAC address of node {0} has been changed. All circuits originating from or dropping at this node will need to be repaired. |
The MAC address of the specified node has been changed. All circuits originating from or dropping at this node need to be repaired. |
WID-2166 |
Unable to insert node into the domain as the node is not initialized. |
Refer to error or warning message text. |
WID-2167 |
Insufficient security privilege to perform this action. |
You have insufficient security privilege to perform this action. |
WID-2168 |
Warnings loading{0}. {1} |
CTC encountered warnings while loading the specified item. |
WID-2169 |
One or more of the profiles selected do not exist on one or more of the nodes selected. |
Refer to error or warning message text. |
WID-2170 |
The profile list on node {0} is full. Please delete one or more profiles if you wish to add profile. |
The profile list on the specified node is full. Please delete one or more profiles if you wish to add the specified profile. |
WID-2171 |
You have been logged out. Click OK to exit CTC. |
Refer to error or warning message text. |
WID-2172 |
The CTC CORBA (IIOP) listener port setting of {0} will be applied on the next CTC restart. |
The specified CTC Common Object Request Broker Architecture (CORBA) Internet Inter-ORB Protocol (IIOP) listener port setting will be applied on the next CTC restart. |
EID-2173 |
Port unavailable. The desired CTC CORBA (IIOP) listener port, {0}, is already in use or you do not have permission to listen on it. Please select an alternate port. |
The port is unavailable. The desired CTC CORBA (IIOP) listener port is already in use or you do not have permission to listen on it. Please select an alternate port. |
EID-2174 |
Invalid number entered. Please check it and try again. |
You entered an invalid firewall port number. |
WID-2175 |
Extension byte mismatch. |
There is a mismatch with the extension byte. |
WID-2176 |
Not all spans have the same OSPF Area ID. This will cause problems with protection switching. To determine the OSPF Area for a given span, click on the span and the OSPF Area will be displayed in the pane to the left of the network map. |
Refer to error or warning message text. |
WID-2178 |
Only one edit pane can be opened at a time. The existing pane will be displayed. |
Refer to error or warning message text. |
WID-2179 |
There is no update as the circuit has been deleted. |
Because the circuit has been deleted, there is no update for it. |
EID-2180 |
CTC initialization failed in step {0}. |
CTC initialization failed in the specified step. |
EID-2181 |
This link may not be included as it originates from the destination. |
Refer to error or warning message text. |
EID-2182 |
The value of {0} is invalid. |
The value of the specified item is invalid. |
EID-2183 |
Circuit roll failure. Current version of CTC does not support bridge and roll on a VCAT circuit. |
Refer to error or warning message text. |
EID-2184 |
Cannot enable the STP on some ports because they have been assigned an incompatible list of VLANs. You can view the VLAN/Spanning Tree table or reassign ethernet ports VLANs. |
Refer to error or warning message text. |
EID-2185 |
Cannot assign the VLANs on some ports because they are incompatible with the Spanning Tree Protocol. You can view the VLAN/Spanning Tree table or reassign VLANs. |
Refer to error or warning message text. |
EID-2186 |
Software download failed on node {0}. |
The software could not be downloaded onto the specified node. |
EID-2187 |
The maximum length for the ring name that can be used is {0}. Please try again. |
You must shorten the length of the ring name. |
EID-2188 |
The nodes in this ring do not support alphanumeric IDs. Please use a ring ID between {0} and {1}. |
The nodes in this ring do not support alphanumeric IDs. Please use a ring ID within the specified range. |
EID-2189 |
TL1 keyword "all" can not be used as the ring name. Please provide another name. |
Refer to error or warning message text. |
EID-2190 |
Adding this span will cause the ring to contain more nodes than allowed. |
Refer to error or warning message text. |
EID-2191 |
Ring name must not be empty. |
You must supply a ring name. |
EID-2192 |
Cannot find a valid route for the circuit creation request. |
Refer to error or warning message text. |
EID-2193 |
Cannot find a valid route for the circuit drop creation request. |
Refer to error or warning message text. |
EID-2194 |
Cannot find a valid route for the roll creation request. |
Refer to error or warning message text. |
EID-2195 |
The circuit VLAN list cannot be mapped to one spanning tree. |
Refer to error or warning message text. |
EID-2196 |
Unable to relaunch the CTC. {0} |
There is an error relaunching CTC. |
EID-2197 |
CORBA failure. Unable to proceed. |
There was a CORBA failure, and the task cannot proceed. |
EID-2198 |
Unable to switch to the {0} view. |
CTC is unable to switch to the specified view. |
EID-2199 |
Login failed on {0} {1} |
The login failed on the specified task. |
EID-2200 |
CTC has detected a jar file deletion. The jar file was used to manage one or more nodes. This CTC session will not be able to manage those nodes and they will appear gray on the network map. It is recommended that you exit this CTC session and start a new one. |
Refer to error or warning message text. |
EID-2202 |
Intra-node circuit must have two sources to be Dual Ring Interconnect. |
Intranode circuit must have two sources to be a dual ring interconnect (DRI). |
EID-2203 |
No member selected. |
You must select a member. |
EID-2204 |
Number of circuits must be a positive integer |
The number of circuits cannot be negative. |
EID-2205 |
Circuit Type must be selected |
You must select a circuit type. |
EID-2206 |
Unable to autoselect profile! Please select profile(s) to store and try again. |
Refer to error or warning message text. |
EID-2207 |
You cannot add this span. Either the ring name is too big (i.e., ring name length is greater than {0}) or the endpoints do not support alphanumeric IDs. |
You cannot add this span. Either the ring name is too big (that is, the ring name length is greater than the specified length) or the endpoints do not support alphanumeric IDs. |
EID-2208 |
This is an invalid or unsupported JRE. |
The version of Java Runtime Environment (JRE) is either invalid or unsupported. |
EID-2209 |
The user name must be at least {0} characters long. |
The user name must be at least the specified character length. |
EID-2210 |
No package name selected. |
You must select a package name. |
EID-2211 |
No node selected for upgrade. |
You must select a node for the upgrade. |
EID-2212 |
Protected Line is not provisionable. |
The protected line cannot be provisioned. |
WID-2213 |
The current type or state of some drops does not allow the new circuit state of {0} to be applied to them indirectly. |
The circuit state, specified by {0} cannot be applied to the selected drops. |
EID-2214 |
The node is disconnected. Please wait till the node reconnects. |
Refer to error or warning message text. |
EID-2215 |
Error while leaving {0} page. |
There was an error while leaving the specified page. |
EID-2216 |
Error while entering {0} page. |
There was an error entering the specified page. |
EID-2217 |
Some conditions could not be retrieved from the network view |
Refer to error or warning message text. |
EID-2218 |
Bandwidth must be between {0} and {1} percent. |
The bandwidth must be within the specified parameters. |
EID-2219 |
Protection operation failed, XC loopback is applied on cross-connection. |
Protection operation failed; a cross-connect (XC) loopback will be applied on cross-connection. |
EID-2220 |
The tunnel status is PARTIAL. CTC will not be able to change it. Please try again later |
Refer to error or warning message text. |
EID-2221 |
Cannot find a valid route for the unprotected to UPSR upgrade request. |
Refer to error or warning message text. |
EID-2222 |
One or more of the following nodes are currently part of a 4-fiber {0}. Only a single 4-fiber {0} is supported per node. |
The nodes, specified by {1}, are already part of a 4-fiber ring type, specified by {0}. |
EID-2223 |
Only one circuit can be upgraded at a time. |
Refer to error or warning message text. |
EID-2224 |
This link may not be included as it terminates on the source. |
Refer to error or warning message text. |
EID-2225 |
No valid signal while trying to complete the roll. (0) |
Refer to error or warning message text. |
EID-2320 |
This VCAT circuit does not support deletion of its member circuits. |
Refer to error or warning message text. |
EID-2321 |
Error deleting member circuits. |
Refer to error or warning message text. |
WID-2322 |
Not all cross-connects from selected circuits could be merged into the current circuit. They may appear as partial circuits. |
Refer to error or warning message text. |
EID-2323 |
Circuit roll failure. Current version of CTC does not support bridge and roll on a DRI protected circuit. |
Refer to error or warning message text. |
EID-2324 |
Circuit upgrade error. {0} |
Refer to error or warning message text. |
EID-2325 |
You have failed {0} times to unlock this session. CTC will exit after you click OK or close this dialog box. |
The maximum amount of attempts to unlock this session has been reached. |
WID-2326 |
Current version of CTC does not support bridge and roll on circuits, which are entirely created by TL1. To continue with bridge and roll in CTC, selected circuits will be ungraded. CAUTION: Once circuits are upgraded, future bridge and roll on the circuits can only be done in CTC. OK to upgrade selected circuits and continue bridge and roll operation? |
Refer to error or warning message text. |
WID-2327 |
Current version of CTC does not support bridge and roll on circuits, which are partially created by TL1. To continue with bridge and roll in CTC, selected circuits must be ungraded. CAUTION: Once circuits are upgraded, future bridge and roll on the circuits can only be done in CTC. OK to upgrade selected circuits and continue bridge and roll operation? |
Refer to error or warning message text. |
EID-2328 |
Circuit reconfigure error. {0} |
Refer to error or warning message text. |
EID-2329 |
{0} of {1} circuits could not be successfully created. |
Refer to error or warning message text. |
EID-2330 |
Circuit verification: selected {0} invalid! {1} |
The selected item, specified by {0}, is invalid as per the details, specified in {1}. |
EID-2331 |
Deleting {0} may be service affecting. |
Refer to error or warning message text. |
EID-2332 |
Hold-off timer validation error in row [0]. |
Refer to error or warning message text. |
EID-3001 |
An Ethernet RMON threshold with the same parameters already exists. Please change one or more of the parameters and try again. |
An Ethernet remote monitoring (RMON) threshold with the same parameters already exists. Please change one or more of the parameters and try again. |
EID-3002 |
Error retrieving defaults from the node: {0} |
There was an error retrieving the defaults from the specified node. |
EID-3003 |
Cannot load file {0}. |
CTC cannot load the specified file. |
EID-3004 |
Cannot load properties from the node |
Refer to error or warning message text. |
EID-3005 |
Cannot save NE Update values to file {0} |
CTC cannot save the network element (NE) update values to the specified file. |
EID-3006 |
Cannot load NE Update properties from the node |
Refer to error or warning message text. |
EID-3007 |
Provisioning Error for {0} |
There was a provisioning error for the specified item. |
EID-3008 |
Not a valid Card |
You cannot perform DWDM automatic node setup (ANS) from the Card view. Please navigate to the Node view and try again. |
EID-3009 |
No {0} selected |
No item selected. |
EID-3010 |
Unable to create bidirectional optical link |
Refer to error or warning message text. |
EID-3011 |
The file {0} doesn't exist or cannot be read. |
The specified file does not exist or cannot be read. |
EID-3012 |
The size of {0} is zero. |
The size of the item is zero. |
EID-3013 |
{0} encountered while restoring database. |
The specified item was encountered while restoring the database (DB). |
EID-3014 |
Job terminated, {0} was encountered. |
The job terminated because the specified item was encountered. |
EID-3015 |
{0} encountered while performing DB backup. |
The specified item was encountered while performing the DB backup. |
EID-3016 |
Invalid subnet address. |
Refer to error or warning message text. |
EID-3017 |
Subnet address already exists. |
Refer to error or warning message text. |
EID-3018 |
Standby TSC not ready. |
The standby Timing and Shelf Control card (TSC) not ready. |
EID-3019 |
Incomplete internal subnet address. |
There is an incomplete internal subnet address. |
EID-3020 |
TSC One and TSC Two subnet addresses cannot be the same. |
Refer to error or warning message text. |
EID-3021 |
An error was encountered while retrieving the diagnostics: {0} |
CTC encountered an error. |
EID-3022 |
Requested action not allowed. |
The requested action is not allowed. |
EID-3023 |
Unable to retrieve low order cross connect mode. |
Refer to error or warning message text. |
EID-3024 |
Unable to switch low order cross connect mode. |
Refer to error or warning message text. |
EID-3025 |
Error while retrieving thresholds. |
The was an error retrieving the thresholds. |
EID-3026 |
Cannot modify send DoNotUse. |
CTC cannot modify the Send DoNotUse field. |
EID-3027 |
Cannot modify SyncMsg. |
CTC cannot modify the SyncMsg field. |
EID-3028 |
Cannot change port type. |
CTC cannot change the port type. |
EID-3029 |
Unable to switch to the byte because an overhead change is present on this byte of the port. |
Refer to error or warning message text. |
EID-3031 |
Error hard-resetting card. |
There was an error hard-resetting card. |
EID-3032 |
Error resetting card. |
There was an error resetting the card. |
EID-3033 |
The lamp test is not supported on this shelf. |
Refer to error or warning message text. |
EID-3035 |
The cross connect diagnostics cannot be performed |
Refer to error or warning message text. |
EID-3036 |
The cross connect diagnostics test is not supported on this shelf. |
The cross-connect diagnostics test is not supported on this shelf. |
EID-3037 |
A software downgrade cannot be performed to the selected version while a SSXC card is inserted in this shelf. Please follow the steps to replace the SSXC with a CXC card before continuing the software downgrade. |
A software downgrade cannot be performed to the selected version while a Single-Shelf Cross-Connect (SSXC) card is inserted in this shelf. Please follow the steps to replace the SSXC with a Core Cross-Connect card (CXC) card before continuing the software downgrade. |
EID-3038 |
A software downgrade cannot be performed at the present time. |
Refer to error or warning message text. |
EID-3039 |
Card change error. |
There was a card change error. |
EID-3040 |
Invalid card type. |
The card type is invalid. |
EID-3041 |
Error applying changes. |
There was an error applying the changes. |
EID-3042 |
The flow control low value must be less than the flow control high value for all ports in the card. |
Refer to error or warning message text. |
EID-3043 |
Error while retrieving line info settings. |
Refer to error or warning message text. |
EID-3044 |
Error while retrieving line admin info settings. |
Refer to error or warning message text. |
EID-3045 |
Error while retrieving transponder line admin info settings. |
Refer to error or warning message text. |
EID-3046 |
The flow control water mark value must be between {0} and {1}, inclusive. |
The flow control watermark value must be between the specified values. |
EID-3047 |
The file named {0} could not be read. Please check the name and try again. |
The specified file could not be read. Please check the name and try again. |
EID-3048 |
There is no IOS startup config file available to download. |
There is no Cisco IOS startup configuration file available to download. |
EID-3049 |
There is an update in progress so the download cannot be done at this time. |
Refer to error or warning message text. |
EID-3050 |
An exception was caught trying to save the file to your local file system. |
Refer to error or warning message text. |
EID-3051 |
The maximum size for a config file in bytes is: {0} |
The maximum size for a configuration file in bytes is the value specified in the message. |
EID-3052 |
There was an error saving the config file to the TCC. |
Refer to error or warning message text. |
EID-3053 |
The value of {0} must be between {1} and {2} |
The value of the item must be between the specified values. |
EID-3054 |
Cannot remove provisioned input/output ports or another user is updating the card, please try later. |
Cannot remove provisioned input or output ports or another user is updating the card. Please try later. |
EID-3055 |
Cannot create soak maintance pane. |
CTC cannot create Soak Maintenance tab. |
EID-3056 |
Cannot save defaults to file {0} |
Cannot save defaults to the specified file. |
EID-3057 |
Cannot load default properties from the node. |
Refer to error or warning message text. |
EID-3058 |
File {0} does not exist. |
The specified file does not exist. |
EID-3059 |
Error encountered while refreshing. |
There was an error in refreshing. |
EID-3060 |
The ALS Recovery Pulse Interval must be between {0} seconds and {1} seconds. |
The automatic laser shutdown (ALS) Recovery Interval must be between 100 seconds and 300 seconds. |
EID-3061 |
The ALS Recovery Pulse Duration must be between {0} seconds and {1} seconds. |
The ALS Recovery Pulse Width must be between 2.00 seconds and 100.0 seconds. |
EID-3062 |
Error encountered while setting values. |
Refer to error or warning message text. |
EID-3063 |
Unable to retriever bridge port settings. |
Refer to error or warning message text. |
EID-3064 |
Not a G1000 Card. |
This card is not a G1000-4 card. |
EID-3065 |
An error was encountered while attempting to create RMON threshold: |
You must wait some time before you try again. |
EID-3066 |
Minimum sample period must be greater than or equal to 10. |
Refer to error or warning message text. |
EID-3067 |
Rising Threshold: Invalid Entry, valid range is from 1 to {0} |
This is an invalid rising threshold entry. The valid range is from 1 to the specified value. |
EID-3068 |
Falling Threshold: Invalid Entry, valid range is from 1 to {0} |
This is an invalid falling threshold entry. The valid range is from 1 to the specified value. |
EID-3069 |
Rising threshold must be greater than or equal to falling threshold. |
Refer to error or warning message text. |
EID-3070 |
Error in data for ports {0} Exactly one VLAN must be marked untagged for each port. These changes will not be applied. |
There was an error in the data for the specified ports. Exactly one VLAN must be marked Untagged for each port. These changes will not be applied. |
EID-3071 |
Get Learned Address |
Unable to retrieve the learned MAC address from the NE. |
EID-3072 |
Clear Learned Address |
Failure attempting to clear the learned MAC address from a specific card or Ether group. |
EID-3073 |
Clear Selected Rows |
Failure attempting to clear the learned MAC address from a specific card or Ether group. |
EID-3074 |
Clear By {0} |
Error encountered trying to clear the learned MAC address from either a VLAN or a port. |
EID-3075 |
At least one row in param column needs to be selected. |
Refer to error or warning message text. |
EID-3076 |
CTC lost its connection with this node. The NE Setup Wizard will exit. |
Refer to error or warning message text. |
EID-3077 |
No optical link selected. |
Refer to error or warning message text. |
EID-3078 |
Unable to create optical link. |
Refer to error or warning message text. |
EID-3079 |
Cannot apply defaults to node: {0} |
Cannot apply defaults to the specified node. |
EID-3080 |
Cannot go to the target tab {0} |
Cannot go to the target tab. |
EID-3081 |
Port type can't be changed. |
Refer to error or warning message text. |
EID-3082 |
Cannot modify the {0} extension byte. |
Cannot modify the extension byte. |
EID-3083 |
Error while retrieving stats. |
Error in getting statistics. |
EID-3084 |
Error encountered while trying to retrieve laser parameters for {0} |
There is no card, or there was an internal communications error when attempting to get the laser statistics from the card. |
EID-3085 |
No OSC Terminations selected |
Refer to error or warning message text. |
EID-3086 |
One or more Osc terminations could not be created. |
Refer to error or warning message text. |
EID-3087 |
OSC termination could not be edited. |
Refer to error or warning message text. |
EID-3088 |
No {0} card to switch. |
No card of the specified type to switch. |
EID-3089 |
Cannot use/change {0} state when {1} is failed or missing. |
Cannot use or change the specified state when it is failed or missing. |
EID-3090 |
Cannot perform operation as {0} is {1}LOCKED_ON/LOCKED_OUT. |
Cannot perform operation. |
EID-3091 |
Cannot perform the operation as protect is active. |
Refer to error or warning message text. |
EID-3092 |
Invalid service state. The requested action cannot be applied. |
Refer to error or warning message text. |
EID-3093 |
Cannot perform the operation as duplex pair is {0}locked. |
Refer to error or warning message text. |
EID-3094 |
Cannot perform the operation as no XC redundancy is available. |
Refer to error or warning message text. |
EID-3095 |
Deletion failed since the circuit is in use |
Refer to error or warning message text. |
WID-3096 |
Internal communication error encountered while trying to retrieve laser parameters. This can happen when equipment is not present or when equipment is resetting. Check the equipment state and try to refresh the values again. |
Refer to error or warning message text. |
EID-3097 |
The ring termination is in use. |
Refer to error or warning message text. |
EID-3098 |
No ring terminations selected. |
Refer to error or warning message text. |
EID-3099 |
Sorry, entered key does not match existing authentication key. |
The entered key does not match existing authentication key. |
EID-3100 |
Error encountered during authentication. |
There was an error in authentication. |
EID-3101 |
DCC Metric is not in the range 1 - 65535. |
The DCC metric is not in the range 1 to 65535. |
EID-3102 |
Invalid DCC Metric |
There was an invalid DCC metric. |
EID-3103 |
Invalid IP Address: {0} |
The IP address is Invalid. |
EID-3104 |
Router priority is not in the range of 0 - 255 |
The router priority is not in the range of 0 to 255. |
EID-3105 |
Invalid Router Priority |
The router priority is Invalid. |
EID-3106 |
Hello Interval is not in the range of 1 - 65535 |
The hello interval is not in the range of 1 to 65535. |
EID-3107 |
Invalid Hello Interval |
The hello interval is Invalid. |
EID-3109 |
Invalid Dead Interval value. Valid range is 1 - 2147483647 |
The dead interval is invalid. |
EID-3110 |
Dead Interval must be larger than Hello Interval |
Refer to error or warning message text. |
EID-3111 |
LAN transit delay is not in the range of 1 - 3600 seconds |
The LAN transit delay is not in the range of 1 to 3600 seconds. |
EID-3112 |
Invalid Transmit Delay |
The transmit delay is invalid. |
EID-3113 |
Retransmit Interval is not in the range 1 - 3600 seconds |
The retransmit interval is not in the range 1 to 3600 seconds. |
EID-3114 |
Invalid Retransit Interval |
The retransmit interval is invalid. |
EID-3115 |
LAN Metric is not in the range 1 - 65535. |
The LAN metric is not in the range 1 to 65535. |
EID-3116 |
Invalid LAN Metric |
The LAN metric is invalid. |
EID-3117 |
If OSPF is active on LAN, no DCC Area Ids may be 0.0.0.0. Please change all DCC Area Ids to non-0.0.0.0 values before enabling OSPF on the LAN. |
Refer to error or warning message text. |
EID-3118 |
If OSPF is active on LAN, LAN Area ID may not be the same as DCC Area Id. |
Refer to error or warning message text. |
EID-3119 |
Validation Error |
CTC was unable to validate the values entered by the user. This error message is common to several different provisioning tabs within CTC (examples include the SNMP provisioning tab, the General> Network provisioning tab, the Security > Configuration provisioning tab, etc.). |
EID-3120 |
No object of type {0} selected to delete. |
No object of the selected type selected to delete. |
EID-3121 |
Error Deleting {0} |
There is an error deleting the item. |
EID-3122 |
No object of type {0} selected to edit. |
No object of the specified type selected to edit. |
EID-3123 |
Error Editing {0} |
There was an error editing the item. |
EID-3124 |
{0} termination is in use. Check if {0} is used by IPCC. |
The specified termination is in use. |
EID-3125 |
No {0} Terminations selected. |
No specified terminations are selected. |
EID-3126 |
{0} termination could not be edited. |
The specified termination could not be edited. |
EID-3127 |
Unable to provision orderwire because E2 byte is in use by {0}. |
Refer to error or warning message text. |
EID-3128 |
The authentication key may only be {0} characters maximum |
The authentication key can only be the specified characters maximum. |
EID-3129 |
The authentication keys do not match! |
Refer to error or warning message text. |
EID-3130 |
Error creating OSPF area virtual link. |
CTC encountered an error creating the Area Virtual Link. |
EID-3131 |
Error creating OSPF virtual link. |
CTC encountered an error creating the Virtual Link. |
EID-3132 |
Error setting OSPF area range: {0}, {1}, false. |
CTC encountered an error setting the area range for the specified values. |
EID-3133 |
Max number of OSPF area ranges exceeded. |
The maximum number of area ranges has been exceeded. |
EID-3134 |
Invalid Area ID. Use DCC OSPF Area ID, LAN Port Area ID, or 0.0.0.0. |
Refer to error or warning message text. |
EID-3135 |
Invalid Mask |
Refer to error or warning message text. |
EID-3136 |
Invalid Range Address |
Refer to error or warning message text. |
EID-3137 |
Your request has been rejected because the timing source information was updated while your changes were still pending. Please retry. |
Refer to error or warning message text. |
EID-3138 |
Invalid clock source for switching. |
Refer to error or warning message text. |
EID-3139 |
Cannot switch to a reference of inferior quality. |
Refer to error or warning message text. |
EID-3140 |
Higher priority switch already active. |
Refer to error or warning message text. |
EID-3141 |
Attempt to access a bad reference. |
Refer to error or warning message text. |
EID-3142 |
No Switch Active. |
Refer to error or warning message text. |
EID-3143 |
Error creating static route entry. |
Refer to error or warning message text. |
EID-3144 |
Max number of static routes exceeded. |
The maximum number of static routes has been exceeded. |
EID-3145 |
RIP Metric is not in the range 1-15. |
The Routing Information Protocol (RIP) metric is not in the range 1 to 15. |
EID-3146 |
Invalid RIP Metric |
Refer to error or warning message text. |
EID-3147 |
Error creating summary address. |
Refer to error or warning message text. |
EID-3148 |
No Layer 2 domain has been provisioned. |
Refer to error or warning message text. |
EID-3149 |
Unable to retrieve MAC addresses. |
Refer to error or warning message text. |
EID-3150 |
The target file {0} is not a normal file. |
The specified target file is not a normal file. |
EID-3151 |
The target file {0} is not writeable. |
The specified target file is not writeable. |
EID-3152 |
Error creating Protection Group |
CTC encountered an error creating Protection Group. |
EID-3153 |
Cannot delete card, it is in use. |
Cannot delete card. It is in use. |
EID-3154 |
Cannot {0} card, provisioning error. |
CTC cannot perform the task on the card. |
EID-3155 |
Error Building Menu |
CTC encountered an error building the menu. |
EID-3156 |
Error on building menu (cards not found for {0} group) |
CTC encountered an error on building the menu (cards not found for the specified group). |
EID-3157 |
Unable to set selected model: unexpected model class {0} |
CTC encountered an unexpected model class while trying to complete the task. |
EID-3158 |
Unable to switch, a similar or higher priority condition exists on peer or far-end card. |
Refer to error or warning message text. |
EID-31591 |
Error applying operation. |
CTC encountered an error applying this operation. |
EID-3160 |
{0} error encountered. |
CTC encountered the displayed error. |
EID-3161 |
Ring Upgrade Error |
An error was encountered while attempting to upgrade the BLSR. Refer to the details portion of the error dialog box for more information. |
EID-3162 |
This protection operation cannot be set because the protection operation on the other side has been changed but not yet applied. |
Refer to error or warning message text. |
EID-3163 |
Cannot validate data for row {0} |
Cannot validate data for the specified row. |
EID-3164 |
New Node ID ({0}) for Ring ID {1} duplicates ID of node {2} |
The new specified node ID for the specified ring ID is the same as the second specified node ID. |
EID-3165 |
The Ring ID provided is already in use. Ring IDs must be unique |
Refer to error or warning message text. |
EID-3166 |
Error refreshing {0} table |
CTC encountered an error refreshing the specified table. |
EID-3167 |
Slot already in use |
Refer to error or warning message text. |
EID-3168 |
Provisioning Error |
An error was encountered while attempting the specified provisioning operation. Refer to the details portion of the error dialog box for more information. |
EID-3169 |
Error Adding Card |
CTC encountered an error adding the card. |
EID-3170 |
Cannot delete card, {0} |
Cannot delete the specified card. |
EID-3171 |
Error creating Trap Destination |
CTC encountered an error creating the trap destination. |
EID-3172 |
No RMON Thresholds selected |
Refer to error or warning message text. |
EID-3173 |
The contact "{0}" exceeds the limit of {1} characters. |
The specified contact exceeds the specified character limit. |
EID-3174 |
The location "{0}" exceeds the limit of {1} characters. |
The specified location exceeds the specified character limit. |
EID-3175 |
The operator identifier "{0}" exceeds the limit of {1} characters. |
The specified operator identifier exceeds the specified character limit. |
EID-3176 |
The operator specific information "{0}" exceeds the limit of {1} characters. |
The specified operator specific information exceeds the specified character limit. |
EID-3177 |
The node name cannot be empty. |
The specified name is empty. |
EID-3178 |
The name "{0}" exceeds the limit of {1} characters. |
The specified name exceeds the specified character limit. |
EID-3179 |
Protect card is in use. |
Refer to error or warning message text. |
EID-3180 |
1+1 Protection Group does not exist. |
Refer to error or warning message text. |
EID-3181 |
Y Cable Protection Group does not exist. |
Refer to error or warning message text. |
EID-3182 |
The Topology Element is in use and cannot be deleted as requested |
Refer to error or warning message text. |
EID-3183 |
Error Deleting Protection Group |
CTC encountered an error deleting the protection group. |
EID-3184 |
No {0} selected. |
You must select an item before completing this task. |
EID-3185 |
There is a protection switch operation on this ring. Therefore, it cannot be deleted at this time. |
Refer to error or warning message text. |
EID-3186 |
Busy {0} is {1} and cannot be deleted as requested. |
The item is in use and cannot be deleted as requested. |
EID-3187 |
Error deleting trap destination. |
CTC encountered an error deleting the trap destination. |
EID-3214 |
Could not get number of HOs for line. |
The number of High Orders for line is not available. |
EID-3215 |
Error in refreshing. |
Used frequently in pane classes to indicate a general error condition when trying to refresh from the model. |
EID-3216 |
Invalid proxy port. |
Invalid Proxy port. |
EID-3217 |
Could not refresh stats. |
Could not refresh statistics. |
EID-3218 |
Unable to launch automatic node setup. |
Refer to error or warning message text. |
EID-3219 |
Unable to refresh automatic node setup information. |
Failure trying to retrieve optical link information. |
EID-3220 |
Error refreshing row {0} |
Error refreshing the specified row. |
EID-3222 |
Could not clear stats. |
Refer to error or warning message text. |
EID-3223 |
Error cancelling software upgrade. |
Refer to error or warning message text. |
EID-3224 |
Error accepting load. |
Refer to error or warning message text. |
EID-3225 |
Error while refreshing pane. |
Refer to error or warning message text. |
EID-3226 |
{0} termination(s) could not be deleted. {1} |
Refer to error or warning message text. |
EID-3227 |
Unable to record a baseline, performance metrics will remain unchanged. |
Refer to error or warning message text. |
EID-3228 |
{0} termination(s) could not be created. {1} |
Refer to error or warning message text. |
EID-3229 |
RIP is active on the LAN. Please disable RIP before enabling OSPF. |
RIP is active on the LAN. Please disable RIP before enabling OSPF. |
EID-3230 |
OSPF is active on the LAN. Please disable OSPF before enabling RIP. |
OSPF is active on the LAN. Please disable OSPF before enabling RIP. |
EID-3231 |
Error in Set OPR |
An error was encountered while attempting to provision the optical power received (OPR). |
EID-3232 |
Cannot transition port state indirectly: try editing directly |
Refer to error or warning message text. |
EID-3233 |
Current loopback provisioning does not allow this state transition |
Refer to error or warning message text. |
EID-3234 |
Current synchronization provisioning does not allow this state transition |
Refer to error or warning message text. |
EID-3235 |
Cannot perform requested state transition on this software version. |
Refer to error or warning message text. |
EID-3236 |
Database Restore failed. {0} |
The specified database restore failed. |
EID-3237 |
Database Backup failed. {0} |
The specified database backup failed. |
EID-3238 |
Send PDIP setting on {0} is inconsistent with that of control node {1} |
The send payload defect indicator path (PDI-P) setting on the specified item is inconsistent with that of the specified control node. |
EID-3239 |
The overhead termination is invalid |
Refer to error or warning message text. |
EID-3240 |
The maximum number of overhead terminations has been exceeded. |
Refer to error or warning message text. |
EID-3241 |
The {0} termination port is in use. |
The specified termination port is in use. |
EID-3242 |
LDCC exists on the selected ports. |
The line DCC (LDCC) exists on the selected ports. Please create SDCC one by one. |
WID-3243 |
LDCC exists on the selected port. |
An LDCC exists on this port. Delete the LDCC after the connection is created. |
EID-3244 |
SDCC exists on the selected ports. |
SDCC exists on the selected ports. Please create LDCC one by one. |
WID-3245 |
The port you have chosen as LDCC endpoint already supports an SDCC. The port cannot support both DCCs. After the LDCC is created, verify that no EOC alarms are present and then delete the SDCC to complete the upgrade. |
Refer to error or warning message text. |
EID-3246 |
Wizard unable to validate data: {0} |
CTC encountered an error. |
EID-3247 |
Ordering error. The absolute value should be {0} |
Ordering error. The absolute value should be the number specified. |
EID-3248 |
Wrong parameter is changed: {0} |
CTC changed the wrong parameter. |
EID-3249 |
Invalid voltage increment value. |
Refer to error or warning message text. |
EID-3250 |
Invalid power monitor range. |
Refer to error or warning message text. |
EID-3251 |
Unable to complete requested action. {0} |
CTC is unable to complete requested action. |
EID-3252 |
No download has been initiated from this CTC session. |
Refer to error or warning message text. |
EID-3253 |
Reboot operation failed. {0} |
The reboot operation failed. |
EID-3254 |
Validation Error. {0} |
The Cisco Transport Controller (CTC) was unable to validate the values entered by the user, specified by {0}. This error message is common to several different provisioning tabs within the CTC. |
EID-3255 |
Can not change timing configuration, manual/force operation is performed. |
Refer to error or warning message text. |
WID-3256 |
Could not assign timing reference(s) because - at least one timing reference has already been used and/or - a timing reference has been attempted to be used twice. Please use the "Reset" button and verify the settings. |
Refer to error or warning message text. |
EID-3257 |
Duplicate DCC number detected: {0}. |
CTC detected a duplicate DCC number. |
EID-3258 |
There was a software error attempting to download the file. Please try again later. |
Refer to error or warning message text. |
EID-3259 |
Create FC-MR Threshold |
You must create an Fibre Channel Multirate (FC_MR) card threshold. |
EID-3260 |
An error was encountered while provisioning the internal subnet: |
Refer to error or warning message text. |
EID-3261 |
The port rate provisioning cannot be changed while circuits exist on this port. |
Refer to error or warning message text. |
EID-3262 |
The port provisioning cannot be changed when the port status is not OOS. |
Refer to error or warning message text. |
WID-3263 |
You are using Java version {0}. CTC should run with Java version {1}. It can be obtained from the installation CD or http://java.sun.com/j2se/ |
CTC is being launched with the wrong version of the JRE {0}. This version of CTC requires a particular version of the JRE {1}. The CTC and browser must be closed and restarted to allow the correct Java version to be loaded. |
EID-3264 |
The port provisioning cannot be changed while the port is in service. |
Refer to error or warning message text. |
EID-3265 |
Error modifying Protection Group |
There was an error modifying the protection group. |
EID-3266 |
Conditions could not be retrieved from the shelf or card view. |
Refer to error or warning message text. |
WID-3267 |
Cannot edit XTC protection group. |
Refer to error or warning message text. |
WID-3268 |
Invalid entry. {0} |
The entry is invalid. |
WID-3269 |
{0} was successfully initiated for {1} but its completion status was not able to be obtained from the node. {0} may or may not have succeeded. When the node is accessible, check its software version. |
The specified task was successfully initiated for the item, but its completion status was not able to be obtained from the node. The task might or might not have succeeded. When the node is accessible, check its software version. |
WID-3270 |
The file {0} does not exist. |
The specified file does not exist. |
WID-3271 |
The value entered must be greater than {0}. |
The value entered must be greater than the value shown. |
WID-3272 |
Entry required |
An entry is required for this task. |
WID-3273 |
{0} already exists in the list. |
The specified item already exists in the list. |
WID-3274 |
A software upgrade is in progress. Network configuration changes that results a node reboot can not take place during software upgrade. Please try again after software upgrade is done. |
Refer to error or warning message text. |
WID-3275 |
Make sure the Remote Interface ID and the Local Interface ID on the two sides are matched. (Local Interface ID on this node should equal Remote Interface ID on the neighbor node and vice-versa.) |
Refer to error or warning message text. |
WID-3276 |
Both SDCC and LDCC exist on the same selected port. |
Refer to error or warning message text. |
WID-3277 |
The description cannot contain more than {0} characters. Your input will be truncated. |
Refer to error or warning message text. |
WID-3279 |
Card deleted, returning to shelf view. |
Refer to error or warning message text. |
WID-3280 |
ALS will not engage until both the protected trunk ports detect LOS. |
Refer to error or warning message text. |
WID-3281 |
A software upgrade is in progress. {0} can not proceed during a software upgrade. Please try again after the software upgrade has completed. |
Refer to error or warning message text. |
WID-3283 |
There is a protection switch or another protection operation applied on the ring. Applying this protection operation now will probably cause a traffic outage. OK to continue? |
Refer to error or warning message text. |
WID-3284 |
Protection Channel Access circuit found on {0} being set to non-revertive. These circuits will not be able to re-establish after ring or span switch. OK to continue? |
Refer to error or warning message text. |
WID-3285 |
Applying FORCE or LOCKOUT operations may result in traffic loss. |
Refer to error or warning message text. |
WID-3286 |
The ring status is INCOMPLETE. CTC cannot determine if there are existing protection operations or switches in other parts of the ring. Applying a protection operation at this time could cause a traffic outage. Please confirm that no other protection operations or switches exist before continuing. |
Refer to error or warning message text. |
WID-3287 |
There is a protection operation or protection switch present on the ring. Applying this protection operation now will probably cause a traffic outage. |
Refer to error or warning message text. |
WID-3288 |
This ring status is INCOMPLETE. CTC will not be able to apply this change to all of the nodes in the {0}. |
Refer to error or warning message text. |
EID-3290 |
Unable to delete specified provisionable patchcord(s). |
Refer to error or warning message text. |
EID-3291 |
Cannot change revertive behavior due to an active protection switch. |
Refer to error or warning message text. |
EID-3292 |
Error resetting shelf. |
Refer to error or warning message text. |
EID-3293 |
No such provisionable patchcord. |
You are attempting to delete a provisionable patchcord that does not exist. This happens when multiple instances of CTC are running and attempting to delete the same provisionable patchcord concurrently. |
EID-3294 |
No RMON thresholds available for selected port. |
Refer to error or warning message text. |
EID-3295 |
This card does not support RMON thresholds. |
Refer to error or warning message text. |
EID-3296 |
Buffer-to-buffer credit is only supported for Fibre Channel (FC) and FICON. |
Refer to error or warning message text. |
EID-3298 |
ALS Auto Restart is not supported by this interface. |
Refer to error or warning message text. |
EID-3300 |
Can not have duplicate OSPF Area IDs. |
Refer to error or warning message text. |
EID-3301 |
LAN metric may not be zero. |
Refer to error or warning message text. |
EID-3302 |
Standby {0} not ready. |
Standby controller card is not ready. |
EID-3303 |
DCC Area ID and {0} conflict. {1} |
DCC Area ID and ring type, specified by {0}, conflict each other due to the details specified by {1}. |
EID-3304 |
DCC number is out of range. |
Refer to error or warning message text. |
EID-3305 |
Can not have OSPF turned on the LAN interface and the back bone area set on a DCC interface. |
You cannot have the default OSPF area on a DCC while OSPF is enabled on the LAN. |
EID-3306 |
Ethernet circuits must be bidirectional. |
Refer to error or warning message text. |
EID-3307 |
Error while creating connection object at {0}. |
Refer to error or warning message text. |
EID-3308 |
DWDM Link can be used only for optical channel circuits. |
Refer to error or warning message text. |
EID-3309 |
OCH-NC circuit: link excluded - wrong direction. |
The optical channel (circuit) does not allow the specified link to be included because it is in the wrong optical direction. |
EID-3310 |
DWDM Link does not have wavelength available. |
Refer to error or warning message text. |
EID-3311 |
Laser already on. |
Refer to error or warning message text. |
EID-3312 |
Unable to change the power setpoint {0} {1} |
Unable to change the power setpoint. The new setpoint would either make the thresholds inconsistent or set the fail threshold outside the range. |
EID-3313 |
Unable to modify offset. Amplifier port is in service state. |
Refer to error or warning message text. |
EID-3314 |
Requested action not allowed. Invalid state value. |
Refer to error or warning message text. |
EID-3315 |
Unable to perform operation. |
CTC is unable to perform operation. |
EID-3316 |
Wrong node side. |
This task was applied to the wrong node side. |
EID-3317 |
Name too long. |
The name you entered is too long. |
EID-3318 |
Illegal name. |
The name you entered is illegal. |
EID-3319 |
Wrong line selection. |
You selected the wrong line. |
EID-3320 |
Unable to delete optical link. |
CTC is unable to delete the optical link. |
EID-3321 |
This feature is unsupported by this version of software. |
Refer to error or warning message text. |
EID-3322 |
Equipment is not plugged-in. |
At least one equipment is not plugged in. |
EID-3323 |
APC system is busy. |
Automatic Power Control (APC) system is busy. |
EID-3324 |
No path to regulate. |
There is no circuit path to be regulated. |
EID-3325 |
Requested action not allowed. |
Generic DWDM provisioning failure message. |
EID-3326 |
Wrong input value. |
The input value is incorrect. |
EID-3327 |
Error in getting thresholds. |
There was an error retrieving the thresholds. This message is displayed only for the OSCM/OSC-CSM line thresholds. |
EID-3328 |
Error applying changes to row {0}.Value out of range. |
There was an error applying the changes to the specified row. The value is out of range. |
EID-3330 |
Unable to switch to the byte because an overhead channel is present on this byte of the port. |
Refer to error or warning message text. |
EID-3331 |
Error applying changes to row. |
There was an error applying changes to the row. |
EID-3334 |
Cannot change timing parameters on protect port. |
You cannot change timing parameters on protect port. |
EID-3335 |
This port's type cannot be changed: SDH validation check failed. Check if this port is part of a circuit, protection group, SONET DCC, orderwire, or UNI-C interface. |
This port's type cannot be changed. The SDH validation check failed. Check to see if this port is part of a circuit, protection group, SONET DCC, orderwire, or user network interface, client (UNI-C) interface. |
EID-3336 |
Error on reading a control mode value. |
The Control Mode must be retrieved. |
EID-3337 |
Error on setting a set point gain value. |
The Gain Set Point must be set. |
EID-3338 |
Error on reading a set-point gain value. |
The Gain Set Point must be retrieved. |
EID-3339 |
Error on setting a tilt calibration value. |
The tilt calibration must be set. |
EID-3340 |
Error on setting expected wavelength. |
The expected wavelength must be set. |
EID-3341 |
Error on reading expected wavelength. |
The expected wavelength must be retrieved. |
EID-3342 |
Error on reading actual wavelength. |
The actual wavelength must be retrieved. |
EID-3343 |
Error on reading actual band. |
The actual band must be retrieved. |
EID-3344 |
Error on reading expected band. |
The expected band must be retrieved. |
EID-3345 |
Error on setting expected band. |
The expected band must be set. |
EID-3346 |
Error retrieving defaults from the node: {0}. |
There was an error retrieving defaults from the specified node. |
EID-3347 |
Cannot load file {0}. |
CTC cannot load the specified file. |
EID-3348 |
Cannot load properties from the node. |
CTC cannot load properties from the node. |
EID-3349 |
Cannot save NE Update values to file. |
CTC cannot save NE Update values to file. |
EID-3350 |
Cannot load NE Update properties from the node: |
CTC cannot load NE Update properties from the node. |
EID-3351 |
File {0} does not exist. |
The specified file does not exist. |
EID-3352 |
Error on setting value at {0}. |
There was an error setting the value at the specified location. |
EID-3353 |
There is no such interface available. |
No such interface exists in CTC. |
EID-3354 |
Specified endpoint is in use. |
The end point is in use. |
EID-3355 |
Specified endpoint is incompatible. |
The end point is incompatible. |
EID-3357 |
Unable to calculate connections. |
CTC is unable to calculate connections. |
EID-3358 |
Optical link model does not exist for specified interface. |
The optical link does not exist for the specified index. |
EID-3359 |
Unable to set optical parameters for the node. |
Refer to error or warning message text. |
EID-3361 |
Ring termination is in use. Error deleting ring termination |
Refer to error or warning message text. |
EID-3362 |
Error deleting ring termination. |
There was an error deleting ring termination. |
EID-3363 |
No ring terminations selected. |
You must select a ring termination. |
EID-3364 |
Error creating ring ID. |
There was an error creating the ring ID. |
EID-3365 |
OSC termination is in use. |
The optical service channel (OSC) termination is in use. |
EID-3366 |
Error deleting OSC termination. |
There was an error deleting the OSC termination. |
EID-3370 |
No optical link has been selected |
You must select an optical link. |
EID-3371 |
Error while calculating automatic optical link list. |
There was an error calculating the automatic optical link list. |
EID-3372 |
Attempt to access an OCH-NC connection that has been destroyed. |
Attempt to access an optical channel network connection that has been destroyed. |
EID-3375 |
Expected span loss must be set. |
Refer to error or warning message text. |
EID-3376 |
Unable to retrieve measured span loss. |
Refer to error or warning message text. |
EID-3377 |
Wrong interface used. |
Refer to error or warning message text. |
EID-3378 |
Duplicate origination patchcord identifier. |
The provisionable patchcord identifier to the patchcord you are attempting to provision is already in use by another patchcord on the origination node. |
EID-3379 |
Duplicate termination patchcord identifier. |
The provisionable patchcord identifier to the patchcord you are attempting to provision is already in use by another patchcord on the remote node. |
EID-3380 |
Unable to locate host. |
Refer to error or warning message text. |
EID-3381 |
Maximum Frame size must be between {0} and {1} and may be increased in increments of {2}. |
Refer to error or warning message text. |
EID-3382 |
Number of credits must be between {0} and {1}. |
Refer to error or warning message text. |
EID-3383 |
GFP Buffers Available must be between {0} and {1} and may be increased in increments of {2}. |
Refer to error or warning message text. |
WID-3384 |
You are about to force the use of Secure Mode for this chassis. You will not be able to undo this operation. OK to continue? |
Refer to error or warning message text. |
EID-3385 |
{0}. Delete circuits, then try again. |
Refer to error or warning message text. |
EID-3386 |
Unable to provision transponder mode: {0} |
Refer to error or warning message text. |
EID-3387 |
You must change port{0} to an out-of-service state before changing card parameters. Click Reset to revert the changes. |
Refer to error or warning message text. |
EID-3388 |
Unable to change the card mode because the card has circuits. |
Refer to error or warning message text. |
EID-3389 |
Error encountered while changing the card mode. |
Refer to error or warning message text. |
EID-3390 |
Port is in use. |
Refer to error or warning message text. |
EID-3391 |
Unable to change the port rate because the port has been deleted. |
Refer to error or warning message text. |
WID-3392 |
Could not assign timing reference(s) because - with external timing, only a single protected, or two unprotected timing references per BITS Out may be selected. Please use the "Reset" button and verify the settings. |
Refer to error or warning message text. |
WID-3393 |
Could not assign timing reference(s) because - with line or mixed timing, only a single unprotected timing reference per BITS Out may be selected. Please use the "Reset" button and verify the settings. |
Refer to error or warning message text. |
WID-3394 |
Error refreshing Power Monitoring values. |
Refer to error or warning message text. |
WID-3395 |
Invalid IP Configuration: {0} |
Error in IP address, net mask length, default router, or a restricted IIOP port was selected. |
EID-3396 |
Invalid Configuration: The standby controller card is not a TCC2P card. |
Refer to error or warning message text. |
EID-3397 |
Wrong version for file {0}. |
The file {0} is of wrong version. |
EID-3398 |
Cannot delete PPM. |
Refer to error or warning message text. |
EID-3399 |
Cannot delete PPM. It has port(s) in use. |
Refer to error or warning message text. |
EID-3400 |
Unable to switch, force to Primary Facility not allowed. |
Refer to error or warning message text. |
EID-3401 |
{0} cannot be provisioned for the port while {1} is enabled. |
The relationship between parameters {0} and {1} are such that enabling either one, prevents the provisioning of the other. |
EID-3402 |
Unable to complete the FORCE operation. The protect card is either not present or is not responding. Please check the protect card state and try again. |
Refer to error or warning message text. |
EID-3403 |
Cannot perform requested state transition on monitored port. |
Refer to error or warning message text. |
EID-3404 |
The far end IP address could not be set on the {0} termination. The IP address cannot be: class D (224.0.0.0/4) class E (240.0.0.0/4) broadcast (255.255.255.255/32) internal {1} |
Refer to error or warning message text. |
EID-4000 |
The {0} ring name cannot be changed now. A {0} switch is active. |
Refer to error or warning message text. |
EID-4001 |
The {0} ring ID cannot be changed now. A {0} switch is active. |
You cannot change the ring ID because a switch of the same ring type is active. |
EID-5000 |
Cannot find a valid route for tunnel change request. |
Refer to error or warning message text. |
EID-5001 |
Tunnel could not be changed. |
Refer to error or warning message text. |
EID-5002 |
Tunnel could not be restored and must be recreated manually. |
Refer to error or warning message text. |
EID-5003 |
Circuit roll failure. {0} |
Refer to error or warning message text. |
EID-5004 |
There is already one 4F {0} provisioned on the set of nodes involved in {1}. The maximum number of 4F {0} rings has been reached for that node. |
There is already one 4F BLSR provisioned on the set of nodes involved in the ring. The maximum number of 4F BLSR rings has been reached for that node. |
WID-5005 |
A non-zero hold-off time can violate switching time standards, and should only be used for a circuit with multiple path selectors. |
Refer to error or warning message text. |
WID-5006 |
Warning: Different secondary {0} node should only be used for DRI or Open-ended path protected circuits. |
You should use different secondary end point only for DRI or open-ended path protected circuits. |
WID-5007 |
If you change the scope of this view, the contents of this profile editor will be lost. |
Refer to error or warning message text. |
WID-5008 |
Please make sure all the protection groups are in proper state after the cancellation. |
Refer to error or warning message text. |
WID-5009 |
Circuit {0} not upgradable. No {1} capable {2}s are available at node {3}. |
No VT capable STSs are available at the node. |
EID-5010 |
Domain name already exists. |
Refer to error or warning message text. |
EID-5011 |
Domain name may not exceed {0} characters. |
Refer to error or warning message text. |
WID-5012 |
Software load on {0} does not support the addition of a node to a 1+1protection group. |
Refer to error or warning message text. |
EID-5013 |
{0} doesn't support Bridge and Roll Feature. Please select a different port. |
Refer to error or warning message text. |
EID-5014 |
An automatic network layout is already in progress, please wait for it to complete for running it again. |
You must for the automatic network layout to complete before running it again. |
WID-5015 |
{0} cannot be applied to {1}. |
You cannot apply the admin state operation, specified by {0}, to port count, specified by {1}. |
EID-5016 |
An error was encountered while attempting to provision the {0}. {1} |
Refer to error or warning message text. |
EID-5017 |
Unable to rollback provisioning, the {0} may be left in an INCOMPLETE state and should be manually removed. |
You may have to remove the BLSR manually as it was left incomplete. |
EID-5018 |
{0} is {1} node and cannot be added to {2} network. |
You cannot add the node {0} of type {1} to the host node of type {2}. This prevents you from hosting both SONET and SDH nodes in the same session. |
EID-5019 |
Manual mode for this equipment does not support an expected string consisting of all null characters. |
The path trace mode does not support strings that consist of null characters. You must either change the expected string or the path trace mode. |
EID-6000 |
Platform does not support power monitoring thresholds |
Refer to error or warning message text. |
EID-6001 |
One of the XC cards has failures or is missing. |
Refer to error or warning message text. |
EID-6002 |
One of the XC cards is locked. |
Refer to error or warning message text. |
EID-6003 |
Unable to create OSC termination. |
Refer to error or warning message text. |
EID-6004 |
Unable to perform a system reset while a BLSR ring is provisioned on the node. |
Refer to error or warning message text. |
EID-6005 |
Could not assign timing references: |
Refer to error or warning message text. |
EID-6006 |
Could not assign timing references: |
Refer to error or warning message text. |
WID-6007 |
Cancelling a software upgrade during standby TSC clock acquisition may result in a traffic outage |
Refer to error or warning message text. |
EID-6008 |
SF BER and SD BER are not provisionable on the protect line of a protection group. |
Refer to error or warning message text. |
WID-6009 |
If Autoadjust GFP Buffers is disabled, GFP Buffers Available must be set to an appropriate value based on the distance between the circuit end points. |
Refer to error or warning message text. |
WID-6010 |
If Auto Detection of credits is disabled, Credits Available must be set to a value less than or equal to the number of receive credits on the connected FC end point. |
Refer to error or warning message text. |
WID-6011 |
Idle filtering should be turned off only when required to operate with non-Cisco FibreChannel/FICON-over-SONET equipment. |
Refer to error or warning message text. |
EID-6012 |
Could not change the retiming configuration. There are circuits on this port |
Refer to error or warning message text. |
EID-6013 |
NTP/SNTP server could not be changed. {1} |
Refer to error or warning message text. |
EID-6014 |
Operation failed. The reference state is OOS. |
Refer to error or warning message text. |
EID-6015 |
Distance Extension cannot be disabled if the port media type is FICON 1Gbps ISL or FICON 2Gbps ISL. |
Refer to error or warning message text. |
EID-6016 |
Card mode cannot be changed to Fibre Channel Line Rate if the port media type is FICON 1Gbps ISL or FICON 2Gbps ISL. |
Refer to error or warning message text. |
EID-6017 |
The destination of a static route cannot be a node IP address. |
Refer to error or warning message text. |
EID-6018 |
The destination of a static route cannot be the same as the subnet used by the node. |
Refer to error or warning message text. |
EID-6019 |
The destination of a static route cannot be 255.255.255.255 |
Refer to error or warning message text. |
EID-6020 |
The destination of a static route cannot be the loopback network (127.0.0.0/8) |
Refer to error or warning message text. |
EID-6021 |
The subnet mask length for a non-default route must be between 8 and 32. |
Refer to error or warning message text. |
EID-6022 |
The subnet mask length for a default route must be 0. |
Refer to error or warning message text. |
EID-6023 |
The destination of a static route cannot be an internal network{0}. |
Refer to error or warning message text. |
EID-6024 |
The destination of a static route cannot be a class D (224.0.0.0/4) or class E (240.0.0.0/4) address. |
Refer to error or warning message text. |
EID-6025 |
The destination of a static route cannot be a class A broadcast address (x.255.255.255/8) |
Refer to error or warning message text. |
EID-6026 |
The destination of a static route cannot be a class B broadcast address (x.x.255.255/16) |
Refer to error or warning message text. |
EID-6027 |
The destination of a static route cannot be a class C broadcast address (x.x.x.255/24) |
Refer to error or warning message text. |
EID-6028 |
The destination of a static route cannot be the subnet broadcast address associated with a node IP address. |
Refer to error or warning message text. |
EID-6029 |
The next hop of a static route cannot be the same as the destination of the route or an internal network{0}. |
Refer to error or warning message text. |
EID-6030 |
The next hop of a static default route must be the provisioned default router. |
Refer to error or warning message text. |
EID-6031 |
No more static routes can be created. |
Refer to error or warning message text. |
EID-6032 |
This static route already exists. |
Refer to error or warning message text. |
EID-6033 |
Previous operation is still in progress. |
Refer to error or warning message text. |
EID-6035 |
Parent entity does not exist. |
Refer to error or warning message text. |
EID-6036 |
Parent PPM entity does not exist. |
Refer to error or warning message text. |
EID-6037 |
Equipment type is not supported. |
Refer to error or warning message text. |
EID-6038 |
Invalid PPM port. |
Refer to error or warning message text. |
EID-6039 |
Card is part of a regeneration group. |
Refer to error or warning message text. |
EID-6040 |
Out of memory. |
Refer to error or warning message text. |
EID-6041 |
Port is already present. |
Refer to error or warning message text. |
EID-6042 |
Port is used as timing source. |
Refer to error or warning message text. |
EID-6043 |
DCC or GCC is present. |
Refer to error or warning message text. |
EID-6044 |
Card or port is part of protection group. |
Refer to error or warning message text. |
EID-6045 |
Port has overhead circuit(s). |
Refer to error or warning message text. |
EID-6046 |
G.709 configuration is not compatible with data rate. |
Refer to error or warning message text. |
EID-6047 |
Port cannot be deleted bacause its service state is OOS-MA,LPBK&MT. |
Refer to error or warning message text. |
EID-6048 |
{0} is {1}. |
Refer to error or warning message text. |
EID-6049 |
Changing the encapsulation type with |
Refer to error or warning message text. |
EID-6050 |
Some {0} terminations were not {1}d. |
Refer to error or warning message text. |
EID-6051 |
All {0} terminations were {1}d successfully. |
Refer to error or warning message text. |
EID-6052 |
The authentication key can not be blank. |
Refer to error or warning message text. |
1 EID-3159 can appear if you attempt to perform another switching operation within a certain time interval. This interval is an algorithm of three seconds per working card in the protection group. The maximum interval is 10 seconds. |