About this Guide
Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This section explains the objectives, intended audience, and organization of this publication and describes the conventions that convey instructions and other information.
This section provides the following information:
•Revision History
•Document Objectives
•Audience
•Related Documentation
•Document Conventions
•Obtaining Optical Networking Information
•Obtaining Documentation and Submitting a Service Request
Revision History
|
|
March 2007 |
Added this Revision History Table |
May 2007 |
The "Upgrade, Add, and Remove Cards and Nodes" chapter was changed for bug CSCsh81654. NTP-G107 was reflowed to include permanently removing DWDM cards as well as removing and replacing them. |
June 2007 |
Added a new procedure, NTP-G192 Force FPGA Update, in the "Provision Transponder and Muxponder Cards" chapter for force FPGA image upgrade. |
October 2007 |
Added NTP-G194 procedure, Set Up the ONS 15454 in Secure Mode Modified the Y-cable module tray requirement to 2 RU in section "DLP-G351 Install the Y-Cable Module Tray" in the "Install the Shelf and Common Control Cards" chapter. Modified the section "Create a Provisionable Patchcord and DCN Extension." Added a new procedure, NTP-G195 Convert a Protected ROADM Node from two Separate Nodes to a Single Multishelf Node, in Add and Remove Cards and Nodes" chapter. Updated the procedure steps for NTP-G186, Perform the Four-Degree and Eight-Degree Mesh Patch Panel Acceptance Test in the "Perform Node Acceptance Tests" chapter. Added a note to configure the Committed Burst Size and Excess Burst Size based on the expected packet size in the "Provision Transponder and Muxponder Cards" chapter Updated task DLP-G8 , Install the Air Ramp in the "Install the Shelf and Common Control Cards" chapter and Updated About this Guide chapter. |
November 2007 |
Added a new procedure, NTP-G196 Force FPGA Update when the Card is part of a Protection Group, in the "Provision Transponder and Muxponder Cards" chapter. |
February 2008 |
Updated note in DLP-G63 in Chapter 3, Turn Up a Node. |
March 2008 |
Deleted a sentence about MMU in NTP-G188 in Chapter 4, Perform Node Acceptance Tests. Updated the procedure to delete a Y-Cable Protection Group and added a note in the "DLP-G177 Delete a Y-Cable Protection Group" section in Chapter 10, "Manage the Node". Added a note indicating that the Administrative State - IS,AINS is not supported on the ADM-10G card. Table 5-33 contains this update and can be located under the procedure "DLP-G397 Change the ADM-10G Line Settings". |
April 2008 |
Updated note in NTP-G33 and DLP-G380 in Chapter 5, Provision Transponder and Muxponder Cards. Added two new notes for Mode and Flow Control parameter in DLP-G380 in Chapter 5, Provision Transponder and Muxponder Cards. Added new NTP-G200, DLP-G464, DLP-G465, DLP-G466, and DLP-G467 in Chapter 7, Create Circuits and Provisionable Patchcords. Added a new parameter in Table 11-37 "40-WXC-C Optical Line Parameter Settings " in the DLP-G408 Change 40-WXC-C Optical Line Parameters section of Chapter 11, Change DWDM Card Settings. Added a note in the NTP-G24 Set Up Name, Date, Time, and Contact Information section of Chapter 3, Turn Up a Node. Added new DLP-G469 Provision the ADM-10G Card Ethernet Settings in Chapter 5, Provision Transponder and Muxponder Cards. Added a note about the impact of removing an SFP from working and protected ports under DLP-G64 Remove an SFP or XFP. |
May 2008 |
Added a note about the impact of a software reset on PM counters for TXP/MXP cards under DLP-G251 Reset DWDM Cards Using CTC. Added a note in the "DLP- G141 View Optical Power Statistics for 32MUX-O, 32WSS, 32WSS-L, 32DMX-O, 32DMX, 32DMX-L, 40-WSS-C, 40-WSS-CE, 40-WXC-C, 40-MUX-C, 40-DMX-C, and 40-DMX-CE Cards" section of Chapter 8, Monitor Performance. Deleted a bullet from the "DLP- G141 View Optical Power Statistics for 32MUX-O, 32WSS, 32WSS-L, 32DMX-O, 32DMX, 32DMX-L, 40-WSS-C, 40-WSS-CE, 40-WXC-C, 40-MUX-C, 40-DMX-C, and 40-DMX-CE Cards" section of Chapter 8, Monitor Performance. |
June 2008 |
Updated MTU and Mode parameters in DLP-G469 in Chapter 5, Provision Transponder and Muxponder Cards. |
July 2008 |
Added DLP-475 View the PM Parameters for All Facilities in Chapter8, Monitor Performance. Updated DLP-G429 in Chapter 11, Change DWDM Card Settings. Added new NTP-G209 Create, Edit, and Delete Optical Sides and DLPs within the NTP. Added a note in Chapter 7, Create Optical Channel Circuits and Provisionable Patchcords, section DLP-G437 Set OCH Circuit Attributes. Updated the fuse ratings in the following sections in Chapter 1, Install the Shelf and Common Control Cards: •DLP-G5 Mount the Shelf Assembly in a Rack (One Person) •NTP-G7 Install the Power and Ground •DLP-G19 Turn On and Verify Office Power •DLP-G6 Mount the Shelf Assembly in a Rack (Two People) •DLP-G7 Mount Multiple Shelf Assemblies in a Rack |
September 2008 |
Following changes made in Chapter 3, Turn Up a Node: •Added a note in G152 Create and Verify Internal Patchcords section •Added notes in G209 Create, Edit, and Delete Optical Sides section •Removed reference to 40-DMX-CE card in the following procedures: –NTP-G185 Install Fiber-Optic Cables between Mesh Nodes –DLP-G430 Install Fiber-Optic Cables from the 40-MUX-C and 40-DMX-C Cards in a Mesh Node to the 40-Channel Patch-Panel Tray |
February 2009 |
•Updated the NTP-G194 procedure title to read as Set Up the ONS 15454 in EMS Secure Access. •Added a note in the "Change the 10G Data Muxponder Port Mode" section of Chapter 5 Provision Transponder and Muxponder Cards. •Updated NTP-G188 in Chapter 4, Perform Node Acceptance Tests. •Updated note in DLP-G387 in Chapter 5, Provision Transponder and Muxponder Cards. |
May 2009 |
•Updated DLP-G381 in the chapter, Provision Transponder and Muxponder Cards. •Updated Ingress COS description in DLP-G380 in Chapter 5, Provision Transponder and Muxponder Cards. •Added note on CVLAN range in DLP- G384 in Chapter 5, Provision Transponder and Muxponder Cards. •Updated "CTC Menu and Toolbar Options" section in Appendix A, CTC Information and Shortcuts. |
June 2009 |
•Updated NTP-G200, DLP-G395, DLP-G463, DLP-G464, DLP-G467, and DLP-G466 in the chapter, Create Circuits and Provisionable Patchcords. •Added a note to the table, GE_XP and 10GE_XP Ethernet RMON Variables in the chapter, Provision Transponder and Muxponder Cards. |
July 2009 |
•Added a note on UNI/NNI port in DLP-G380 in Chapter 5, Provision Transponder and Muxponder Cards. •Updated a note in the section "DLP-G346 Provision Optical Channel Client Connections" in Chapter 7, Create Optical Channel Circuits and Provisionable Patchcords. |
September 2009 |
•Added a note in "G144 Provision a Multishelf Node" section of Chapter 3, Turn Up a Node. |
October 2009 |
•Updated the "Clean Fiber Optic Connectors" procedure in Chapter 13, "Maintain the Node". •Added the "Clean Multi Fiber-Optic Cable Connectors" procedure in Chapter 13, "Maintain the Node". |
November 2009 |
•Added a note in "10GE_XP or GE_XP Ethernet Settings " table of Chapter , Provision Transponder and Muxponder Cards. •Updated the figure for fan tray assembly (ANSI) in Chapter, "Install the Shelf and Common Control Cards" and Chapter, "Maintain the Node". •Added a note in "Delete a PPM" procedure in the chapter, "Provision Transponder and Muxponder Cards". •Updated the section "DLP-G381 Provision the GE_XP and 10GE_XP Layer 2 Protection Settings" in the chapter "Provision Transponder and Muxponder Cards". |
March 2010 |
•Updated the table 10GE_XP or GE_XP Ethernet Settings in the chapter Provision Transponder and Muxponder Cards |
April 2010 |
•Added a note after "10GE_XP or GE_XP Ethernet Settings " table. |
June 2010 |
•Updated the table with EAP cable length in NTP-G145 in the chapter, Install the Shelf and Common Control Cards. |
July 2010 |
Deleted the section "DLP-G313 Verify OSC-CSM Transmit Power" in the chapter "Turn Up a Node". |
October 2010 |
•Added two notes and a step in "DLP-G18 Connect Office Power to the ONS 15454 ANSI" of the chapter, "Install the Shelf and Common Control Cards". •Updated step 1 in"DLP-G19 Turn On and Verify Office Power" of the chapter, "Install the Shelf and Common Control Cards". |
November 2010 |
•Added Step 11 and a note to Step 9 in the procedure, "DLP-G18 Connect Office Power to the ONS 15454 ANSI". •Updated Step 1 in the procedure "DLP-G19 Turn On and Verify Office Power". •Updated step 21 in "NTP-G42 Perform the Terminal Node with 32WSS and 32DMX Cards Acceptance Test" •Updated step 22 in "NTP-G153 Perform the Terminal Node with 32WSS-L and 32DMX-L Cards Acceptance Test" •Updated step 21 in "NTP-G167 Perform the Terminal Node with 40-WSS-C and 40-DMX-C Cards Acceptance Test" |
March 2011 |
Added a note in the sections "Set the 40-WXC-C OCHNC Parameters", "Perform the Native Mesh Node Acceptance Test", and "Perform the Node Upgrade Acceptance Test". |
April 2011 |
•Updated step 5 in the procedures "DLP-G463 Create an Automatically Routed STS or VC Circuit" and "DLP-G464 Create a Manually Routed STS or VC Circuit" in the chapter "Create Optical Channel Circuits and Provisionable Patchcords". •Added a note in the procedure "DLP-G403 Create the ADM-10G Peer Group" in the chapter "Provision Transponder and Muxponder Cards". |
June 2011 |
•Updated step 5 in the procedure "Remove Permanently or Remove and Replace DWDM Cards" of the chapter, "Upgrade, Add, and Remove Cards and Nodes". |
October 2011 |
•Updated step 6 in the procedure "DLP-G384 Provision the GE_XP and 10GE_XP QinQ Settings" in the chapter "Provision Transponder and Muxponder Cards". |
December 2011 |
•Updated the procedure "DLP-G76 Provision DCC/GCC Terminations" in the chapter "Create Optical Channel Circuits and Provisionable Patchcords". •Updated the following procedures in the chapter "Manage the Node": –NTP-G85 Modify or Delete OSC Terminations, DCC/GCC Terminations, and Provisionable Patchcords –DLP-G184 Change a DCC/GCC Termination –DLP-G185 Delete a DCC/GCC Termination |
February 2012 |
•Updated the procedure "DLP-G379 Change the GE_XP or 10GE_XP Card Mode" in the chapter "Provision Transponder and Muxponder Cards". •Updated the Mode parameter in the table "ADM-10G Card Ethernet Settings" in the chapter "Provision Transponder and Muxponder Cards". •Updated the procedure "DLP-G278 Provision the Optical Line Rate" in the chapter "Provision Transponder and Muxponder Cards". |
March 2012 |
•Updated the bandwidth parameter in the procedure, "DLP-G383 Provision the GE_XP and 10GE_XP Quality of Service Settings" of the chapter "Provision Transponder and Muxponder Cards". •Added a note in the procedure "NTP-G354 Create an Internal Patchcord Manually" in the chapter "Turn Up a Node". |
April 2012 |
Added a note in the procedure "DLP-G368 Change the 10G Multirate Transponder Trunk Wavelength Settings" in the chapter "Provision Transponder and Muxponder Cards". |
May 2012 |
Updated the "Set Up SNMP" procedure in the chapter "Turn Up a Node". |
June 2012 |
Document Part Number revisioned to 78-17704-02 and a full length book-PDF was generated. |
July 2012 |
•Updated the table "GE_XP and 10GE_XP Ethernet RMON Variables" in the chapter "Provision Transponder and Muxponder Cards". •Updated the task "NTP-G130 Remove a DWDM Node" in the chapter "Add and Remove Nodes". |
September 2012 |
•Added the "NTP-G333 Add an ADM-10G Card to an Existing Topology" in the chapter "Provision Transponder and Muxponder Cards". •Updated the procedures "NTP-G60 Create and Delete Overhead Circuits" and "DLP-G76 Provision DCC/GCC Terminations" in the chapter "Create Optical Channel Circuits and Provisionable Patchcords". •Updated the procedure "NTP-G38 Provision OSC Terminations" in the chapter "Turn Up a Node". |
Document Objectives
This document explains installation, turn up, provisioning, and maintenance for Cisco ONS 15454 dense wavelength division (DWDM) systems. Use this document in conjunction with the appropriate publications listed in the Related Documentation section.
Audience
To use this publication, you should be familiar with Cisco or equivalent optical transmission hardware and cabling, telecommunications hardware and cabling, electronic circuitry and wiring practices, and preferably have experience as a telecommunications technician
Related Documentation
Use the Cisco ONS 15454 DWDM Procedure Guide in conjunction with the following referenced publications:
•Cisco ONS 15454 DWDM Reference Manual, Release 8.0
•Cisco ONS 15454 DWDM Troubleshooting Guide, Release 8.0
•Cisco ONS SONET TL1 Command Guide, Release 8.0
•Cisco ONS SONET TL1 Reference Guide, Release 8.0
•Cisco ONS SONET TL1 Command Quick Reference Guide, Release 8.0
•Cisco ONS 15454 SDH TL1 Command Guide, Release 8.0
•Cisco ONS 15454 SDH TL1 Reference Guide, Release 8.0
•Cisco ONS 15454 SDH TL1Command Quick Reference Guide, Release 8.0
•Release Notes for Cisco ONS 15454 Release 8.0
•Release Notes for Cisco ONS 15454 SDH Release 8.0
•Cisco Metroplanner DWDM Operations Guide, Release 8.0
For an update on End-of-Life and End-of-Sale notices, refer to:
http://www.cisco.com/en/US/products/hw/optical/ps2006/prod_eol_notices_list.html
Document Conventions
This publication uses the following conventions:
|
|
boldface |
Commands and keywords in body text. |
italic |
Command input that is supplied by the user. |
[ ] |
Keywords or arguments that appear within square brackets are optional. |
{ x | x | x } |
A choice of keywords (represented by x) appears in braces separated by vertical bars. The user must select one. |
Ctrl |
The control key. For example, where Ctrl + D is written, hold down the Control key while pressing the D key. |
screen font |
Examples of information displayed on the screen. |
boldface screen font |
Examples of information that the user must enter. |
< > |
Command parameters that must be replaced by module-specific codes. |
Note Means reader take note. Notes contain helpful suggestions or references to material not covered in the document.
Caution
Means
reader be careful. In this situation, the user might do something that could result in equipment damage or loss of data.
|
Warning
|
|
IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071 SAVE THESE INSTRUCTIONS |
Waarschuwing |
BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt raadplegen. BEWAAR DEZE INSTRUCTIES |
Varoitus |
TÄRKEITÄ TURVALLISUUSOHJEITA Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla. SÄILYTÄ NÄMÄ OHJEET |
Attention |
IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil, référez-vous au numéro de l'instruction situé à la fin de chaque avertissement. CONSERVEZ CES INFORMATIONS |
Warnung |
WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden. BEWAHREN SIE DIESE HINWEISE GUT AUF. |
Avvertenza |
IMPORTANTI ISTRUZIONI SULLA SICUREZZA Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti. Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le traduzioni delle avvertenze riportate in questo documento. CONSERVARE QUESTE ISTRUZIONI |
Advarsel |
VIKTIGE SIKKERHETSINSTRUKSJONER Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med elektriske kretser, og kjenne til standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne enheten. TA VARE PÅ DISSE INSTRUKSJONENE |
Aviso |
INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo. GUARDE ESTAS INSTRUÇÕES |
¡Advertencia! |
INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo. GUARDE ESTAS INSTRUCCIONES |
Varning! |
VIKTIGA SÄKERHETSANVISNINGAR Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR |
|
|
|
|
|
|
|
|
|
|
Aviso |
INSTRUÇÕES IMPORTANTES DE SEGURANÇA Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham o dispositivo. GUARDE ESTAS INSTRUÇÕES |
Advarsel |
VIGTIGE SIKKERHEDSANVISNINGER Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Obtaining Optical Networking Information
This section contains information that is specific to optical networking products. For information that pertains to all of Cisco, refer to the Obtaining Documentation and Submitting a Service Request section.
Where to Find Safety and Warning Information
For safety and warning information, refer to the Cisco Optical Transport Products Safety and Compliance Information document that accompanied the product. This publication describes the international agency compliance and safety information for the Cisco ONS 15454 system. It also includes translations of the safety warnings that appear in the ONS 15454 system documentation.
Cisco Optical Networking Product Documentation CD-ROM
Optical networking-related documentation, including Cisco ONS 15xxx product documentation, is available in a CD-ROM package that ships with your product. The Optical Networking Product Documentation CD-ROM is updated periodically and may be more current than printed documentation.
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.